adr manual

Download ADR Manual

Post on 16-Apr-2015

115 views

Category:

Documents

5 download

Embed Size (px)

TRANSCRIPT

Altium ADRAdd-Drop Multiplexer

TM

Installation and Operation Manual

PN 567-170201-003 Rev.

Copyright 2001 by DMC Stratex Networks. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, magnetic, optical, chemical, manual or otherwise, without the prior written permission of DMC Stratex Networks.

Printed in the United States of America. Disclaimer DMC Stratex Networks makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties or merchantability or fitness for any particular purpose. Further, DMC Stratex Networks reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of DMC Stratex Networks to notify any person of such revision or changes.

This equipment has been tested for and meets EMC Directive 89/336/EEC. The equipment was tested using screened cabling. If any other type of cable is used, it may violate compliance. CE Mark This equipment has been designed to meet the requirements of the European Electromagnetic Compatibility Directive 89/336/EEC (currently amended by 92/31/EEC). Operation of the equipment is designed to provide reasonable protection against harmful interference in its electromagnetic environment without introducing intolerable electromagnetic disturbances. Trademarks FibreNex and Altium are trademarks and DMC Net is a registered trademark of DMC Stratex Networks. All other product names are trademarks or registered trademarks of their respective companies.DMC Stratex Networks 170 Rose Orchard Way San Jose, California 95134-1358 U.S.A. Telephone: (408) 943-0777 Telex: 759597 DIGMIC Fax: (408) 944-1801 www.dmcwave.com DMC Stratex Networks Middlemarch Business Park Siskin Drive Coventry, England CV3-4JA Telephone: + 44-1203-863838 Fax: + 44-1203-530126 DMC Stratex Networks 10 Ang Mo Kio Street 65 #03-13 Techpoint Singapore 569059 Telephone: + 65-484-7780 Fax: + 65-484-7768

Ports Security LevelThe following table lists port safety levels for the 19" subrack access.Connectors on the Front Panel PWRA/PWRB PWR Motherboard SYNC E1 INPUT & E1 OUTPUT MNGT COMM ETH LOOPS ADR ICI 1.x Card TR and REC EOW and AUX ADR ERE Card TR and REC ADR LAN1 Card ETH ADR E3DS3 Card TR and REC ADR 21E120 Card E1 INPUT & E1 OUTPUT G.703 2 Mbit/s Ports SELV 34 or 45 Mbps ports SELV Ethernet Port SELV STM-1 electrical ports SELV G.957 and G.958 STM-1 IC1.1 or IC1.2 Optical Engineering Order WireLaser class 1

Function Power supply Power supply

Security Level SELV1 SELV

G.703 2 Mbit/s synchronization Ports G.703 2 Mbit/s Ports Other equipment connection VT100 local supervision Ethernet LAN remote supervision Loops and remote signaling

SELV SELV SELV SELV SELV SELV

No Danger SELV

1. SELV = Safety Extra Low Voltage circuit

Caution:

The 19" subrack must be mounted only in racks with a bottom part that is closed or fitted with a class V1 or HF1 or better air filter, or that stand on a non-flammable floor. This equipment must be installed only by skilled personnel. For compliance, the protective grounding (earth) terminal must be connected to a safe ground (earth) with an impedance Z of less than 5 Ohms. Before working inside the equipment, wear an antistatic wrist strap.

W arning:

Replacing the lithium battery incorrectly could result in explosion. Only authorized personnel at DMC Stratex Networks Product Support Center may replace this component. Dispose of all used batteries according to manufacturers instructions.

Declaration of Conformity I hereby declare that the product:Altium ADR(Name of product, type or model, batch or serial number)

satisfies all the technical regulations applicable to the product within the scope of Council Directives 73/23/EEC, 89/336/EEC and 99/5/EC:Altium 6GHz STM-1-EN 300 234, ETS 300 385, EN 60 950. Altium 7/8GHz STM-1- EN 300 234, ETS 300 385, EN 60 950. Altium 13 GHz STM-1-EN 300 234, ETS 300 385, EN 60 950. Altium 15GHz STM-1-EN 300 234, ETS 300 385, EN 60 950. Altium 18GHz STM-1-EN 300 430, ETS 300 385, EN 60 950. Altium 23GHz STM-1-EN 300 198, ETS 300 385, EN 60 950. Altium 26GHz STM-1-ETS 300 431, ETS 300 385, EN 60 950. Altium 28GHz STM-1-ETS 300 431, ETS 300 385, EN 60 950. Altium 38GHz STM-1-EN 300 197, ETS 300 385, EN 60950. (Title(s) of regulations, standards, etc.)

All essential radio test suites have been carried out.

NOTIFIED BODY: TUV Produktservice GmbH Address: Ridlerstrasse 65 80339 Munchen Germany (Notified body: 0123) MANUFACTURER or AUTHORISED REPRESENTATIVE: Address: DMC Stratex Networks 170 Rose Orchard Way San Jose CA 95134 USA

This declaration is issued under the sole responsibility of the manufacturer and, if applicable, his authorised representative.Point of contact:Stuart Little, +1 408 943 0777 (Tel), +1 408 943 1678 (Fax)(Name, telephone and fax number)

San Jose, 22 March 2001(Place, date of issue) (Signature) Stuart Little, Director of Product Marketing (Name and title in block letters)

000-000085-FRM-A

Intended Use of EquipmentThe Altium radio is classified under the R&TTE Directive 99/5/EC as a class 2.8 radio (microwave fixed link) product. Point-to-point radio relay equipment is intended to be used for interconnecting typically private and public networks and for interconnecting mobile base stations back to the PSTN point of presence (POP). Altium equipment operates in fixed bands between 6 GHz and 38 GHz and is available in capacity STM-1. For details of where the equipment is intended to be used, refer to the Country matrix below. A licence to operate this apparatus is likely to be necessary and the appropriate regulatory administration should be contacted.

Luxembourg

Netherlands

Switzerland

Germany

Denmark

Portugal

Sweden

Belgium

Norway

Greece

Finland

Austria

France

Ireland

Spain

Italy

Altium 6GHz STM-1 Altium 7/8GHz STM-1 Altium 13GHz STM-1 Altium 15GHz STM-1 Altium 18GHz STM-1 Altium 23GHz STM-1 Altium 26GHz STM-1 Altium 28GHz STM-1 Altium 38GHz STM-1

X X X

X X X X

X X X X X X X X X

X X

X X X X

X X X

X X X X

X X X X X X X X X

X X X X X X

X X X X X X X

X X X X X X X X X

X X X X X X X X

X X X X X X X X X X X X

X X X X X X X X X

X

X X X X X X X

X X X X X

X X X X X

X

X X

X X X X X

X X X X X

X X X

X X X

X X

X X

Note: The information contained in this document has been gathered from the relevant government authorities and relates only to European countries participating in the R&TTE Directive.

UK

X X X X X X X X X

ContentsChapter 1Installation and Commissioning Overview ...................................................................................................................... 11 Subrack Installation ...................................................................................................... 14 Installation of a 19" Rack ......................................................................................... 14 Installation of an ETSI Rack .................................................................................... 14 Installation of Cards ................................................................................................. 15 Connecting Ports ........................................................................................................... 15 Connection Requirements ........................................................................................ 15 Connecting Power Supply Ports .............................................................................. 16 Connection Requirements ................................................................................. 16 Connecting Motherboard Inputs .............................................................................. 19 Remote Indication, Remote Control, and Station Alarm Ports ("LOOPS")...... 19 Management and Administration Ports ........................................................... 110 X24/V11 2 Mbps traffic port ........................................................................... 112 G.703 2 Mbps Synchronization port ............................................................... 115 G.703, 21 x 2 Mbps traffic port ....................................................................... 115 Connecting on the ADR IC1.x Card ...................................................................... 117 Connecting STM-1 interface ........................................................................... 117 Connecting Order-Wire Channels ................................................................... 118 Connecting with MSP Operation..................................................................... 121 Connecting on the ADR ERE Card ........................................................................ 123 Connecting on ADR LAN1 Card ........................................................................... 124 Connecting an ADR E3DS3 Card .......................................................................... 125 Connecting an ADR 21E120 Card ......................................................................... 126 75 W Connecting Strip ........................................................................................... 127 Commissioning ....................................................................................................