Interpretation: VIII-77-43
Subject: Section VIII, Division 1, Radiography of Formed Heads
Date Issued: April 25, 1977
File: NA
Question: For cold formed heads to be used in Section VIII, Division 1 vessels and where
radiography of the weld seams in the head is required, what are the requirements for the appropriate
sequence of cold forming and radiography?
Reply: Section VIII, Division 1 does not contain any specific requirements pertaining to the
sequence of radiography and cold forming of heads required to be radiographed. Therefore, it is up to
the vessel manufacturer to use his judgment for such an application.
Interpretation: VIII-77-44
Subject: Section VIII, Division 1, U-1, Classification of Sterilizers
Date Issued: April 28, 1977
File: BC76-187
Question: What Code requirements apply to a sterilizer of 9 in. I.D. which generates steam for
internal use only and which is heated by a strip heater mounted on the outside?
Reply: Such a sterilizer is within the scope of Section VIII, Division 1. It could be built under
the provisions of U-1(j) as a "UM" vessel. The sterilizer is not an unfired steam boiler or a fired pressure
vessel, so the requirements of UW-2(c) or (d) are not mandatory.
However, we caution you that the laws at the point of installation may dictate the
construction. As indicated by footnote 1 to U-1, Scope, such laws must be reviewed to determine
requirements that may be different or more restrictive than the Code rules.
Interpretation: VIII-77-45Subject: Section VIII, Division 1, U-1, Classification of Autoclaves
Date Issued: April 28, 1977
File: BC76-187
Question: What Code requirements apply to an autoclave of 6 in. I.D. which generates steam for
internal use only and which is heated by a strip heater mounted on the outside?
Reply: Such an autoclave is not within the scope of Section VIII, Division 1 when the inside
diameter does not exceed 6 in. [See U-1(c)(9)]. However, if desired, such an autoclave could be
constructed in accordance with Section VIII, Division 1 rules [See U-1(i)]. The mandatory rules are not
influenced by the location of the heater. The autoclave is not an unfired steam boiler or a fired pressure
vessel, so the requirements of UW-2(c) or (d) are not mandatory.However, we caution you that the laws at the point of installation may dictate the
construction. As indicated by footnote to U-1, Scope, such laws must be reviewed to determine
requirements that may be different or more restrictive than the Code rules.