  • 7/27/2019 864-15

    1/1

    Interpretation: VIII-77-43

    Subject: Section VIII, Division 1, Radiography of Formed Heads

    Date Issued: April 25, 1977

    File: NA

    Question: For cold formed heads to be used in Section VIII, Division 1 vessels and where

    radiography of the weld seams in the head is required, what are the requirements for the appropriate

    sequence of cold forming and radiography?

    Reply: Section VIII, Division 1 does not contain any specific requirements pertaining to the

    sequence of radiography and cold forming of heads required to be radiographed. Therefore, it is up to

    the vessel manufacturer to use his judgment for such an application.

    Interpretation: VIII-77-44

    Subject: Section VIII, Division 1, U-1, Classification of Sterilizers

    Date Issued: April 28, 1977

    File: BC76-187

    Question: What Code requirements apply to a sterilizer of 9 in. I.D. which generates steam for

    internal use only and which is heated by a strip heater mounted on the outside?

    Reply: Such a sterilizer is within the scope of Section VIII, Division 1. It could be built under

    the provisions of U-1(j) as a "UM" vessel. The sterilizer is not an unfired steam boiler or a fired pressure

    vessel, so the requirements of UW-2(c) or (d) are not mandatory.

    However, we caution you that the laws at the point of installation may dictate the

    construction. As indicated by footnote 1 to U-1, Scope, such laws must be reviewed to determine

    requirements that may be different or more restrictive than the Code rules.

    Interpretation: VIII-77-45Subject: Section VIII, Division 1, U-1, Classification of Autoclaves

    Date Issued: April 28, 1977

    File: BC76-187

    Question: What Code requirements apply to an autoclave of 6 in. I.D. which generates steam for

    internal use only and which is heated by a strip heater mounted on the outside?

    Reply: Such an autoclave is not within the scope of Section VIII, Division 1 when the inside

    diameter does not exceed 6 in. [See U-1(c)(9)]. However, if desired, such an autoclave could be

    constructed in accordance with Section VIII, Division 1 rules [See U-1(i)]. The mandatory rules are not

    influenced by the location of the heater. The autoclave is not an unfired steam boiler or a fired pressure

    vessel, so the requirements of UW-2(c) or (d) are not mandatory.However, we caution you that the laws at the point of installation may dictate the

    construction. As indicated by footnote to U-1, Scope, such laws must be reviewed to determine

    requirements that may be different or more restrictive than the Code rules.

    Interpretation: VIII-77-46

    Subject: Section VIII, Division 1, U-1, Classification of Autoclaves

    Date Issued: April 28, 1977

    File: BC76-518