3500/44m aeroderivative monitor datasheet€¦ · n generalelectric:lm1600,lm2500,lm5000,lm6000 n...

12
3500/44M Aeroderivitive GT Vibration Monitor Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/44M Aeroderivitive GT Vibration Monitor is a four- channel instrument designed for aeroderivative gas turbine applications. The Aero GT I/O modules interface to velocity transducers through Bently Nevada* interface modules, part numbers 86517 and 86497. The monitor uses the Prox/Velom I/O to interface to our Velomitor* sensors and accelerometers. Using the 3500 Rack Configuration Software, you can configure the 3500/44M Aeroderivitive GT Vibration Monitor for the following filter options: n Signal Integration n 1X vibration tracking n Band-pass vibration The 3500/44M Aeroderivitive GT Vibration Monitor accepts input from two separate Keyphasor* signals, allowing each channel pair to use a different tracking filter. The 3500/44M Aeroderivitive GT Vibration Monitor meets the recommended requirements of the following aeroderivative gas turbine manufacturers: n Rolls Royce: RB211, Avon n General Electric: LM1600, LM2500, LM5000, LM6000 n United Technologies: Turbo Power GG 3, G44, FT 4, FT 8 The primary purpose of the 3500/44M Aeroderivitive GT Vibration Monitor is to provide the following: n Machinery protection by continuously comparing monitored parameters against configured alarm setpoints to drive alarms n Essential machine information for both operations and maintenance personnel You can configure multimode channels to have up to eight sets of alarm parameters including alert and danger setpoints and Part Number: 143441-01 Rev. M Page 1 of 12

Upload: lengoc

Post on 04-Jun-2018

242 views

Category:

Documents


1 download

TRANSCRIPT

3500/44M Aeroderivitive GT Vibration Monitor

Product DatasheetBently Nevada* Asset Condition Monitoring

DescriptionThe 3500/44MAeroderivitive GT Vibration Monitor is a four-channel instrument designed for aeroderivative gas turbineapplications. The Aero GT I/O modules interface to velocitytransducers through Bently Nevada* interfacemodules, partnumbers 86517and 86497. Themonitor uses the Prox/Velom I/Oto interface to our Velomitor* sensors and accelerometers.

Using the 3500Rack Configuration Software, you can configurethe 3500/44MAeroderivitive GT Vibration Monitor for thefollowing filter options:

n Signal Integrationn 1X vibration trackingn Band-pass vibration

The 3500/44MAeroderivitive GT Vibration Monitor accepts inputfrom two separate Keyphasor* signals, allowing each channelpair to use a different tracking filter.

The 3500/44MAeroderivitive GT Vibration Monitormeets therecommended requirements of the following aeroderivative gasturbinemanufacturers:

n Rolls Royce: RB211, Avonn General Electric: LM1600, LM2500, LM5000, LM6000n United Technologies: Turbo Power GG 3, G44, FT 4, FT 8

The primary purpose of the 3500/44MAeroderivitive GT VibrationMonitor is to provide the following:

n Machinery protection by continuously comparing monitoredparameters against configured alarm setpoints to drive alarms

n Essential machine information for both operations and maintenancepersonnel

You can configuremultimode channels to have up to eight setsof alarmparameters including alert and danger setpoints and

Part Number: 143441-01Rev. M

Page 1 of 12

alarm time delays. Each setmay be configured fora specific machinemode.

As themachine changesmodes, themonitor canswitch to a specific set using contacts onmultimode I/O modules or software commandsthrough a communications gateway.

Part Number: 143441-01Rev. M

Page 2 of 12

Specifications

Inputs

SignalAccepts 1 to 4 signals from interfacemodules (part numbers 86517 and 86497),velomitors and accelerometers

Power consumption 7.7 watts, typical

Input Impedance

Aero GT I/OGreater than 95 kΩ(Proximitor and acceleration inputs)

Prox/Velom I/O andMultimodeProx/Velom I/O

10 kΩ for Prox/Accel3.5 MΩ for Velomitor

Sensitivity

Aeroderivative3.94 mV/(mm/s) (100mV/(in/s)) or5.71 mV/(mm/s) (145mV/(in/s))

Aeroderivative2 andMultimodeAeroderivative

3.94 mV/(mm/s) (100mV/(in/s)),5.71 mV/(mm/s) (145mV/(in/s)),10.19 mV/(m/s2) (100 mV/g),2.55 mV/(m/s2) (25 mV/g) or1.02 mV/(m/s2) (10 mV/g)

Outputs

Front Panel LEDs

OK LEDIndicates when the 3500/44M AeroderivitiveGT Vibration Monitor is operating properly.

TX/RX LEDIndicates when the 3500/44M AeroderivitiveGT Vibration Monitor is communicating withother modules in the 3500 Rack.

Bypass LEDIndicates when the 3500/44M AeroderivitiveGT Vibration Monitor is in Bypass Mode.

BufferedTransducerOutputs

The front of each monitor has one coaxialconnector for each channel.

Each connector is short-circuit protected.

OutputImpedance

550 Ω

TransducerPower Supply

-23 Vdc nominal at 43 mA max

Recorder

+4 to +20 mAOutput is proportional to monitor full-scale.

One output is provided for each channel.

Monitor operation is unaffected by shortcircuits on recorder outputs.

VoltageCompliance(current output)

0 to +12 Vdc range across load

Load resistance is 0 to 600 Ω.

Resolution

0.3662 µA per bit±0.25% error at room temperature

±0.7% error over temperature range

Update rate 100 ms or less

Part Number: 143441-01Rev. M

Page 3 of 12

Signal Conditioning

Specified at +25 ºC (+77 ºF) unless otherwise noted.

Aeroderivative

Accuracy

Within ±0.33% of full-scale typical±1% maximum

Exclusive of filters

Frequency Response

Direct signal 4 Hz to 30 kHz, -3 dB

Direct Signal - Bandpass Filter

Low-pass corner 200 Hz (-3 dB)

Low-pass rolloff10-pole200 dB per decade60 dB per octave

High-pass corner 25, 75 or 100 Hz (-3 dB)

High-pass rolloff10-pole200 dB per decade60 dB per octave

Direct Signal - Tracking Filter

Tracking filterValid for machine speeds of 60 to 240,000cpm

Constant QUser-configurable by selecting one of 22normal operating speeds from 2,400 to18,000 RPM and by bandwidth of 3 or 5Hz

Rolloff6-pole120 dB per decade36 dB per octave

Aeroderivative2 and Multimode Aeroderivative

Accuracy

Within ±0.33% of full-scale typical±1% maximum

Exclusive of filters

Frequency Response

Direct Signal - Bandpass Filter

Non-integratedvelocity

4 Hz to 5500 Hz (-3 dB)

Integrated velocity 18 Hz to 5500 Hz (-3 dB)

Non-integratedacceleration

4 Hz to 30,000 Hz (-3 dB)

Integratedacceleration

18 Hz to 14,500 Hz (-3 dB)

Bias low-pass filter 0.01 Hz (-3 dB)

Bandpass Filter

Low-pass cutofffrequency

Configurable between 100 Hz and 5500Hz (-3 db)

Low-pass rolloff8-pole160 dB per decade48 dB per octave

High-pass cutofffrequency

Configurable between 10 Hz and 1000 Hz(-3 dB)

High-pass rolloff8-pole160 dB per decade48 dB per octave

Tracking filterTracking filter is valid for machinespeeds of 60 to 300,000 cpm

Tracking Filter

Constant Q

User configurable

You can select one of 35 normaloperating speeds from 2,400 to 30,000RPM and bandwidth of 3 or 5 Hz.

Rolloff6-pole120 dB per decade36 dB per octave

Part Number: 143441-01Rev. M

Page 4 of 12

Alarms

Alarm setpoints

You can set Alert levels for various valuesmeasured by the monitor and Dangersetpoints for up to two of the valuesmeasured by the monitor usingconfiguration software.

Alarms are adjustable from 0 to 100% offull-scale for each measured valueexcept when the full-scale rangeexceeds the range of the transducer. Inthis case, the range of the transducer willlimit the setpoint.

Alarm accuracy Within 0.13% of the desired value

AeroderivativeDirect1X AmplitudeBandpass

Aeroderivative2

DirectBandpass1X Amplitude1X Phase Lag

MultimodeAeroderivative

DirectDirect-BBandpassBandpass-B1X Ampl1X Ampl-B1X Phase Lag

Alarm Time Delays

For Aeroderivative channels, you can setone alert and one danger delay for eachchannel.

For Aeroderivative2 and MultimodeAeroderivative channels, you can setdelays for each proportional valuehaving alarm setpoints.

AlertFrom 1 to 60 seconds in 1 secondintervals

Danger0.1 seconds or from 1 to 60 seconds in 1second intervals

Proportional Values

Proportional values aremeasurements used tomonitor themachine. The 3500/44MAeroderivitiveGT Vibration Monitor provides the followingproportional values:

AeroderivativeDirect1X AmplitudeBandpass

Aeroderivative2

DirectBandpassBias1X Amplitude1X Phase Lag

Multimode Aeroderivative

DirectDirect-BBandpassBandpass-B1X Ampl1X Ampl-B1X Phase LagMode

Physical

Monitor Module (Main Board)

Dimensions(Height x Width x Depth)

241.3 mm x 24.4 mm x 241.8 mm(9.50 in x 0.96 in x 9.52 in)

Weight 0.91 kg (2.0 lb)

I/O Modules

Dimensions(Height x Width x Depth)

241.3 mm x 24.4 mm x 99.1 mm(9.50 in x 0.96 in x 3.90 in)

Weight 0.45 kg (1.0 lb)

Rack Space Requirements

Monitor Module 1 full-height front slot

I/O Modules 1 full-height rear slot

Part Number: 143441-01Rev. M

Page 5 of 12

Hazardous Area ApprovalsFor the detailed listing of country and product specificapprovals, refer to the Approvals Quick ReferenceGuide, document 108M1756, atwww.GEmeasurement.com.

CSA/NRTL/C (Approval Option 01)

When used with I/O moduleordering options and internalbarriers

Ex nC [ia] IIC T4 GcClass I, Division 1,Groups A, B, C and D

Class I, Zone 2/0AEx nC [ia] IIC T4 GcClass I, Division 1Groups A, B, C and D

T4 @ -20 °C ≤ Ta +65 °C(-4 °F to +149 °F)per drawing 138547

When used with I/O moduleordering options withoutinternal barriers

nC [L] IIC T4 GcClass I, Division 2,Groups A, B, C and D

Class I, Zone 2AEx nC IIC T4 GcClass I, Division 2Groups A, B, C and D

T4 @ -20 °C ≤ Ta +65 °C(-4 °F to +149 °F)per drawing 149243

ATEX/IECEx (Approval Option 02)

For ATEX/IECEx agencyapproval ordering optionswith internal barriers

II 3 (1) GEx nA nC ic [ia Ga] IIC T4 Gc

T4 @ -20 °C ≤ Ta +65 °C(-4 °F to +149 °F)

For ATEX/IECEx agencyapproval ordering optionswithout internal barriers

II 3 GEx nA nC ic IIC T4 Gc

T4 @ -20 °C ≤ Ta +65 °C(-4 °F to +149 °F)

Environmental Limits

Operating Temperature-30°C to +65°C(-22°F to +149°F)

Storage Temperature-40°C to +85°C(-40°F to +185°F)

Humidity95%Non-condensing

Compliance and Certifications

EMC

Standards:EN 61000-6-2 Immunity for IndustrialEnvironmentsEN 61000-6-4 Emissions for IndustrialEnvironments

European Community Directives:EMC Directive 2014/30/EU

Electrical Safety

Standards:EN 61010-1

European Community Directives:LV Directive 2014/35/EU

Part Number: 143441-01Rev. M

Page 6 of 12

Ordering InformationFor the detailed listing of country and product specificapprovals, refer to the Approvals Quick ReferenceGuide, document 108M1756, atwww.GEmeasurement.com.

Aeroderivative Monitor3500/44 - AXX - BXX

A: I/O Module Type01 Aero GT I/O Module with Internal

Terminations02 Aero GT I/O Module with External

Terminations05 Prox/Velom I/O Module with Internal

Terminations06 Prox/Velom I/O Module with External

Terminations07 Multimode Prox/Velom I/O Module with

Internal Terminations08 Multimode Prox/Velom I/O Module with

External Terminations

B: Agency Approval00 None01 CSA / NRTL / C (Class I, Division 2)02 ATEX / IECEx / CSA (Class I, Zone 2)

External Termination Blocks

125808-03Aeroderivative ET BlockEuro Style Connectors

125808-08Prox/Velom External Termination BlockEuro Style connectors

125808-11Multimode Prox/Velom ExternalTermination BlockEuro Style connectors

125808-13Multimode Recorder Output and ModeInput External Termination BlockEuro Style connectors

128702-01Recorder External Termination BlockEuro Style connectors

128015-03Aeroderivative External TerminationBlockTerminal Strip Connectors

128015-08Prox/Velom External Termination BlockTerminal Strip Connectors

128015-11Multimode Prox/Velom ExternalTermination BlockTerminal Strip connectors

128015-13

Multimode Recorder Output and ModeInput External Termination Block

Terminal Strip connectors

128710-01Recorder External ET Block

Terminal Strip connectors

Part Number: 143441-01Rev. M

Page 7 of 12

Cables

3500 Transducer (XDCR) to ExternalTermination (ET) Block Cable129525 - AXXXX - BXX

A: I/O Cable length

0005 5 feet (1.5 metres)0007 7 feet (2.1 metres)0010 10 feet (3.0 metres)0025 25 feet (7.6 metres)0050 50 feet (15.2 metres)0100 100 feet (30.5 metres)

B: Assembly instructions01 Not assembled02 Assembled

3500 Recorder Output to External Termination(ET) Block Cable129529 - AXXXX - BXX

A: I/O Cable length

0005 5 feet (1.5 metres)0007 7 feet (2.1 metres)0010 10 feet (3.0 metres)0025 25 feet (7.6 metres)0050 50 feet (15.2 metres)0100 100 feet (30.5 metres)

B: Assembly instructions01 Not assembled02 Assembled

Spares

176449-033500/44M Aeroderivitive GTVibration Monitor

143490-013500/44M Aeroderivitive GTVibration Monitor Manual

126599-01Aero GT I/O Module InternalTerminations

140471-01Prox/Velom I/O Module withInternal Terminations

140482-01Prox/Velom I/O Module withExternal Terminations

169459-01Multimode Prox/Velom I/OModule with InternalTerminations

169459-02Multimode Prox/Velom I/OModule with ExternalTerminations

00580434

Euro Style connector header8 pinGreen

For use on I/O modules withinternal terminations

00580432

Euro Style connector header10 pinGreen

For use on I/O modules withinternal terminations

00561941Prox/Velom and MultimodeProx/Velom I/O Module ten-pinconnector shunt

Part Number: 143441-01Rev. M

Page 8 of 12

Graphs and FiguresThis section includes the following graphs and figures:

n Front and rear views of the 3500/44M Aeroderivitive GT Vibration Monitor

See Front and Rear Views of the 3500/44M Aeroderivitive GT Vibration Monitor on page 10.

n The side view of the Prox/Velom I/O and Multimode Prox/Velom I/O with internal and external terminations

See Side View of I/O Modules on page 11.

Part Number: 143441-01Rev. M

Page 9 of 12

Front and Rear Views of the 3500/44M Aeroderivitive GT Vibration Monitor

1: Status LEDs2: Buffered Transducer Outputs3: 3500/44M Aeroderivitive GT Vibration Monitor Main Module4: Aero GT I/O Module with Internal Terminations5: Aero GT I/O Module with External Terminations6: Prox/Velom I/O, Internal Terminations7: Prox/Velom I/O, External Terminations8: Multimode Prox/Velom I/O, Internal Terminations9: Multimode Prox/Velom I/O, External Terminations

Part Number: 143441-01Rev. M

Page 10 of 12

Side View of I/O Modules

Prox/Velom I/O modules and Multimode Prox/Velom I/O modules with internal and external terminationshave the same jumpers.

Part Number: 143441-01Rev. M

Page 11 of 12

©1999 - 2017Bently Nevada LLC All rights reserved.* Denotes a trademark of Bently Nevada LLC, a wholly owned subsidiary of General Electric Company.

All product and company names are trademarks of their respective holders.Use of the trademarks does not imply any affiliation with or endorsement by the respective holders.

The information contained in this document is subject to changewithout prior notice.Printed in USA. Uncontrolled when transmitted electronically.1631Bently Parkway South, Minden, Nevada USA 89423Phone: 1-775.782.3611www.GEmeasurement.com

Part Number: 143441-01Rev. M

Page 12 of 12