312786j - dump valve and third flush valve kits ... · 312786j en instructions-parts dump valve and...
TRANSCRIPT
312786JEN
Instructions-Parts
Dump Valve and Third Purge Valve Kits
For use with ProMix® 2KS Electronic Proportioners. For professional use only.See page 2 for kit part numbers and maximum working pressure.
Important Safety InstructionsRead all warnings and instructions in this manual. For complete warnings and instructions see your proportioning system manual. Hazard symbols refer to specific procedure risks. Save all instruc-tions.
TI12743a
TI12954a
15V821 Dump Valve Kit for Wall Panel
15V354 Third Flush Valve Kit for Wall Panel, shown on Fluid Mix Manifold
2 312786J
ContentsKits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315V821 and 17L060 Dump Valve Kits for Wall Panel
315V354 Third Flush Valve Kit for Wall Panel . . . 515V822 Dump Valve Kit for RoboMix . . . . . . . . . 615V202 Third Flush Valve Kit for RoboMix . . . . . 715X247 Auto Dump Valve Kit . . . . . . . . . . . . . . . 8
Schematic Diagrams . . . . . . . . . . . . . . . . . . . . . . . 10System Pneumatic Schematic . . . . . . . . . . . . . 10Tubing Schematic . . . . . . . . . . . . . . . . . . . . . . . 11
System Electrical Schematic . . . . . . . . . . . . . . . 13Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
15V821 Dump Valve Kit for Wall Panel . . . . . . . 1417L060 Dump Valve Kit for Wall Panel . . . . . . . 1515V354 Third Flush Valve Kit for Wall Panel . . . 1615V822 Dump Valve Kit for RoboMix . . . . . . . . 1715V202 Third Flush Valve Kit for RoboMix . . . . 1815X247 Auto Dump Valve Kit . . . . . . . . . . . . . . 19
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 20Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 20
Kits15V821 and 17L060 Dump Valve KitsFor wall mount ProMix 2KS Electronic Proportioners3000 psi (21 MPa, 210 bar) Maximum Fluid Working Pressure100 psi (0.7 MPa, 7 bar) Maximum Air Working PressureSee pages 3 and 14
15V822 Robo Dump Valve KitFor robo mount ProMix 2KS Electronic Proportioners300 psi (2.1 MPa, 21 bar) Maximum Fluid Working Pressure100 psi (0.7 MPa, 7 bar) Maximum Air Working PressureSee pages 6 and 17
15V354 Third Flush Valve KitFor wall mount ProMix 2KS Electronic Proportioners4000 psi (28 MPa, 280 bar) Maximum Fluid Working Pressure100 psi (0.7 MPa, 7 bar) Maximum Air Working PressureSee pages 5 and 16
15V202 Robo Third Flush Valve KitFor robo mount ProMix 2KS Electronic Proportioners300 psi (2.1 MPa, 21 bar) Maximum Fluid Working Pressure100 psi (0.7 MPa, 7 bar) Maximum Air Working PressureSee pages 7 and 18
15X247 Auto Dump Valve KitFor wall mount ProMix 2KS Electronic Proportioners3000 psi (21 MPa, 210 bar) Maximum Fluid Working Pressure100 psi (0.7 MPa, 7 bar) Maximum Air Working PressureSee pages 8 and 19
Installation
312786J 3
Installation
15V821 and 17L060 Dump Valve Kits for Wall PanelNOTE: These instructions show this kit being installed on the A side. It may also be installed on the B side.
1. Shut off the fluid supply to the dose valve (V) at the front of the wall panel.
2. Actuate the dose valve to relieve fluid pressure in the valve.
3. Relieve fluid pressure upstream and downstream of the dose valve. See your ProMix 2KS Operation Manual.
4. See FIG. 1. Remove the plug from the dose valve adapter. Install the street elbow (18) in this port. Install the nipple (19) in the elbow.
5. Install the dump valve assembly (includes 1, 2, 4, and 11) in a slot of the flange (F) at the back of the wall panel. Secure with the nut (8).
6. Install the elbow (6) in the open port of the dump valve adapter (2). Connect a 1/4 npsm(f) hose (12) between the elbow (6) and nipple (19).
7. Shut off all power to the fluid panel. Open the fluid panel. See the Wall Panel detail in FIG. 2. Install the solenoid (9) at the correct position (Dump Valve A or Dump Valve B) on the solenoid manifold. Con-nect the solenoid wires to the fluid panel control board as shown in FIG. 3. Also see the System Electrical Schematic on page 13.
8. Connect the tubing (7) between the solenoid mani-fold and the tube fitting (T) on the dump valve (1). See System Pneumatic Schematic, page 10.
FIG. 1: 15V821 Kit Installation
TI12744a TI12743a
At Back of Wall PanelAt Front of Wall Panel
1
V
18 6
8
F
T
2
12
12
A SIDE B SIDE
19
Installation
4 312786J
FIG. 2: Solenoid Manifolds
FIG. 3: 255765 Fluid Panel Control Board, Detail View of Solenoid Connections
TI13116a
Wall Panel
3rd FlushValve
Dump Valve A
Dump Valve B
RoboMix Panel
TI12655a
3rd Flush Valve
Dump Valve A
DumpValve B
GFB1
GFB2
J15-1 J15-2 J15-6J15-5 J8-6J8-5
3rd Purge Valve Dump Valve A Dump Valve BAuto Dump
Valve A (GFB1)Auto Dump
Valve B (GFB2) Wire Color
J15-1 J15-5 J8-5 J8-3 J8-1 Red
J15-2 J15-6 J8-6 J8-4 J8-2 Black
J8-1 J8-2 J8-3 J8-4
Installation
312786J 5
15V354 Third Flush Valve Kit for Wall Panel
1. Shut off the air and fluid supply to the ProMix 2KS.
2. Relieve pressure. See your ProMix 2KS Operation Manual.
3. See FIG. 4. Remove the air flush valve (AFV) from the fluid mix manifold (FM) and set it aside.
4. See FIG. 5. Install the o-ring (6), double valve mounting block (1), and screws (8).
5. See FIG. 6. Install the air flush valve (AFV) on the double valve block (1). Assemble the third flush valve kit parts (2, 3, 4, 6, 9, 10, 11) as shown on page 16. Install on the mounting block using the screws (7). See FIG. 6.
6. Shut off all power to the fluid panel. Open the fluid panel. See the Wall Panel detail in FIG. 2. Install the solenoid (12) and two tube connectors (15) at the correct position (3rd Flush Valve) on the solenoid manifold. Connect the solenoid wires to the fluid panel control board as shown in FIG. 3.
7. Connect the tubing (13, 14) between the solenoid manifold and the tube fittings (T) on the flush valve (2). See System Pneumatic Schematic, page 10.
FIG. 4: Disconnect Air Flush Valve
TI12955a
FM
AFV
FIG. 5: Install Double Valve Mounting Block
FIG. 6: Install Third Flush Valve
TI12956a
6
1
8
TI12957a
1
AFV
7
2
Installation
6 312786J
15V822 Dump Valve Kit for RoboMixNOTE: These instructions show this kit being installed on the B side. It may also be installed on the A side.
1. See FIG. 7. Shut off the fluid supply to the dose valve (V) in the RoboMix.
2. Actuate the dose valve to relieve fluid pressure in the valve.
3. Relieve fluid pressure upstream and downstream of the dose valve. See your ProMix 2KS Operation Manual.
4. Remove the plug from the dose valve adapter. Apply thread sealant and install the elbow (8) in this port.
5. Install the valve adapter (3) in the RoboMix. Secure with four screws (11). Apply thread sealant and install the nipple (9) through the back of the Robo-Mix and into the adapter. Install the swivel (6) in the opposite side of the adapter.
6. Install the seat (2), o-ring (10), and dump valve (1) in the adapter (3).
7. Connect the hose (5) between the swivel (6) and elbow (8).
8. Shut off all power to the fluid panel. Open the fluid panel. See the RoboMix Panel detail in FIG. 2. Install the solenoid (4) at the correct position (Dump Valve A or Dump Valve B) on the solenoid manifold. Connect the solenoid wires to the fluid panel control board as shown in FIG. 3. Also see the System Electrical Schematic on page 13.
9. Connect the tubing (13) between the solenoid mani-fold and the tube fitting (T) on the dump valve (1). See System Pneumatic Schematic, page 10.
Installation
312786J 7
15V202 Third Flush Valve Kit for RoboMix
1. Shut off the air and fluid supply to the ProMix 2KS.
2. Relieve pressure. See your ProMix 2KS Operation Manual.
3. See FIG. 8. Remove the plug (A) from the air flush valve (AFV). Install an o-ring (6) in this port.
4. Install the third flush valve adapter (3) in the Robo-Mix. Ensure that the o-ring (6) remains in place to seal between the adapter and the air flush valve adapter.
5. Secure the adapter (3) to the air flush valve adapter with four screws (10) inserted through the side wall of the RoboMix. Torque to 70 in-lb (8 N•m).
6. Apply thread sealant and install the check valve (4) through the back of the RoboMix and into the third flush valve adapter (3).
7. Install the o-ring (2), seat (1), o-ring (6), and third flush valve (5) in the adapter (3).
8. See FIG. 8. Shut off all power to the fluid panel. Open the fluid panel. Install the solenoid (8) in the third flush valve position on the solenoid manifold. Install the tube connector (9). Connect the solenoid wires to the fluid panel control board as shown in FIG. 3. Also see the System Electrical Schematic on page 13.
9. Connect the tubing (13) between the solenoid mani-fold and the tube fitting (T) on the third flush valve (5). See System Pneumatic Schematic, page 10.
10. Connect the third flush fluid supply line to the check valve (4).
FIG. 7: 15V822 Kit Installation
TI13045a
TI12655a
Dump Valve A
DumpValve B
TI13047a
4
11
9
1
10
2 36
5
8
T
V
Installation
8 312786J
15X247 Auto Dump Valve Kit
1. Close the component A and component B shutoff valves on the fluid manifold.
2. Trigger the gun to relieve fluid pressure downstream of the fluid manifold.
3. See FIG. 9. Install the small o-ring (3), seat retainer (6), large o-ring (7), and dump valve (1) in the valve adapter (2).
4. Install the valve adapter (2) in the mixed material line, downstream of the static mixer and as close to the gun as possible.
NOTE: Connect the static mixer to one 1/4 npt port of the valve adapter.
5. Install the nipple (8) in the other port of the adapter (2). Connect the gun line to this nipple.
6. Connect a 1/4 npsm(f) dump hose (not supplied) to the 1/4 npsm(m) threaded stud at the bottom of the adapter (2). When the gun closes, the dump valve opens and fluid is dumped through the stud.
7. Shut off all power to the fluid panel. Open the fluid panel. See the Wall Panel detail in FIG. 9. Install the solenoid (5) at the correct position (GFB1 or GFB2) on the solenoid manifold. Connect the solenoid wires to J8 on the fluid panel control board as shown in FIG. 3. Also see the System Electrical Schematic on page 13.
8. Install the tube connector (9) in the solenoid mani-fold. Connect the tubing (4) between the connector and the tube fitting (T) on the dump valve (1). See System Pneumatic Schematic, page 10.
FIG. 8: 15V202 Kit Installation
TI12655a
TI13047aTI13046a
5
6
1
10
3
2
4
8
9
6
T
Installation
312786J 9
FIG. 9: 15X247 Kit Installation
TI14283b
1
2
3
6
7
8
TI13116a
5
9
4
T
GFB
1G
FB2
J8 (see FIG. 3 for details)
Wall Panel
Schematic Diagrams
10 312786J
Schematic Diagrams
System Pneumatic Schematic
3/8 AIR FILTERMANUAL DRAIN5 MICRONWALL MOUNT ONLY
FLUS
H AI
R TO
FLUI
D IN
LET
1/4 T
UBE
TO M
ANIFO
LD
1/4 T
UBE
4-WAY SOLENOID
12 VDC
PURGE AVALVE
DUMP AVALVE(OPTIONAL)
4-WAY SOLENOID
12 VDC
3-WAY SOLENOID
12 VDC
3-WAY SOLENOID
12 VDC
MANIFOLDAIR EXHAUST MUFFLER
OPEN
CLOSE
OPEN5/32 TUBE
5/32 TUBE
PURGE BVALVE
4-WAY SOLENOID
12 VDC
CLOSE
OPEN5/32 TUBE
DUMP BVALVE(OPTIONAL)
4-WAY SOLENOID
12 VDC
OPEN5/32 TUBE
A B
A B
A B
A B
A
A
DOSE AVALVECLOSE
OPEN5/32 TUBE
DOSE BVALVECLOSE
OPEN5/32 TUBE
3-WAY SOLENOID
12 VDCGFB 1VALVE(OPTIONAL)5/32 TUBE
A
COLOR 1COLOR 2COLOR 3COLOR 4COLOR 5COLOR 6COLOR 7COLOR 8COLOR SOLVENTCOLOR 9COLOR 10COLOR 11COLOR 12CATALYST 1CATALYST 2CATALYST 3CATALYST 4CATALYST SOLVENT
COLORCHANGECONTROL
COLORVALVESTACKS
MAC36 SERIES SOLENOID VALVES
05
COLOR 13COLOR 14COLOR 15COLOR 16COLOR 17COLOR 18COLOR 19COLOR 20COLOR 21COLOR 22COLOR 23COLOR 24COLOR 25COLOR 26COLOR 27COLOR 28COLOR 29COLOR 30
PURGE CVALVE(OPTIONAL)4-WAY SOLENOID
12 VDC
CLOSE
OPEN5/32 TUBE
A B
AIR EXHAUST MUFFLER
3-WAY SOLENOID
12 VDCGFB 2VALVE(OPTIONAL)
OPEN5/32 TUBE
A
OPEN
MANIFOLD
AIR INPUT
AIR INPUT
PU
RG
E A
IR
CO
NTR
OL
AIR
Schematic Diagrams
312786J 11
Tubing Schematic
TI13862a
TI13857a TI13858a
A2
A4
A6
A8
A2 A4 A6 A8
B1 B3 B5 B7
B1
B3
B5
B7
13
13
DA DB
DADB
TI13861a TI13860aTI13863a
GFB1-C GFB2-C
GFB1-S
GFB2-S
GFB1-P
GFB2-P
GFB1-A
GFB2-A
ATOM-1
ATOM-2ATOM-1 ATOM-2
GFB1-C
GFB2-C
GFB1-S GFB2-S
GFB1-P
GFB2-P
GFB1-A GFB2-A
GFB1
GFB2
AT
Schematic Diagrams
12 312786J
Table 1: Tubing Chart
Color Description Starting PointEnding Point
Tube OD in. (mm) Tube Ref. No.
Green Dose A On A2 A2 5/32 (4) 336
Green Dose B On A4 A4 5/32 (4) 336
Green Purge A On A6 A6 5/32 (4) 336
Green Purge B On A8 A8 5/32 (4) 336
Green Dump A DA DA 5/32 (4) Included in optional Dump Valve Kit 15V821
Green Dump B DB DB 5/32 (4)
Red Dose A Off B1 B1 5/32 (4) 337
Red Dose B Off B3 B3 5/32 (4) 337
Red Purge A Off B5 B5 5/32 (4) 337
Red Purge B Off B7 B7 5/32 (4) 337
Natural Solenoid Air Supply 13 13 1/4 (6) 334
Natural Gun Flush Box 1 Pressure Switch Signal
GFB1-A GFB1-A 5/32 (4)
Included in optional Gun Flush Box Kit 15V826
Natural Gun Flush Box 2 Pressure Switch Air
GFB2-A GFB2-A 5/32 (4)
Natural Gun Flush Box 1 Trigger Air
GFB1-C GFB1-C 5/32 (4)
Natural Gun Flush Box 2 Trigger Air
GFB2-C GFB2-C 5/32 (4)
Natural Gun Flush Box 1 Supply Air
GFB1-P GFB1-P 5/32 (4)
Natural Gun Flush Box 2 Supply Air
GFB2-P GFB2-P 5/32 (4)
Natural Gun Flush Box 1 Safety Interlock
GFB1-S GFB1-S 5/32 (4)
Natural Gun Flush Box 2 Safety Interlock
GFB2-S GFB2-S 5/32 (4)
Natural Gun 1 Atomizing Air ATOM-1 ATOM-1 1/4 (6) User supplied. Con-nects air flow switch to gun air shutoff valve.
Natural Gun 2 Atomizing Air ATOM-2 ATOM-2 1/4 (6)
Natural Purge Air Supply Use as a separate line connected directly to the main shop air line. Do not connect to the unit’s main air supply or to the air manifold (335).
AT 1/4 (6) 338
Schematic Diagrams
312786J 13
System Electrical Schematic
Hazardous Area
HAZARDOUS AREA
+12VDC I/SCOMSHIELD
J10123
123456
J3
PWR (RED)COM (BLACK)SIG (WHITE)SHIELD/GRNPWR (RED)COM (BLACK)SIG (WHITE)SHIELD/GRNPWR (RED)COM (BLACK)SIG (WHITE)SHIELD/GRN
FLUIDPANELCONTROLBOARD
FLUID PANEL CONTROL BOX
FLOW METER A
FLOW METER B
123456
J5
12345
FLOWCONTROLBOARD
654321
J9
BLACKREDBLACKREDBLACKRED
MANIFOLD
NOT USED
DOSE B
DOSE A
12345678910
J1
SIGCOMSIGCOMSIGCOMSIGCOMSIGCOM
AIR FLOW SWITCH 1
FO OUT (BLU)
FO IN(BLK)
12
J1J2
3X CABLE
FLOW METER SOLVENT
12345
TECNOV/P
FLUIDPRESS.SENS.
J4
SIG (RED)COM (BLK)
+ PRESSURE (GRN)COM (RED)EX+ (WHT)- PRESSURE (BLK)SHIELD (BARE)
32541
J11GRD (BLK)+12VDC (RED)SHIELD (BARE)CAN H (WHT)CAN L (BLU)
J7/J111 4 5 2 3
COLORBOARD 1(COLORS1 THRU 12, CATALYST1 THRU 4)
CLR 9
CLR 10
CLR 11
1 4 5 2 3
V/P ANALOG OUT (WHT)PRESS. (GRN)+12 V (RED)GND (BLK)CHASSIS (BARE)
MH2
(10')/(40')
6' STD.
6' STD.(3'-100' OPTIONS)
I.S. METERS
32541
GRD (BLK)+12VDC (RED)SHIELD (BARE)CAN H (WHT)
CAN L (BLU)
32541
BOOTHCONTROLBOARD
654321
J14
BLACKREDBLACKREDBLACKRED
AIR FLOW SWITCH 2
SOLVENT FLOW SWITCH
GFB 1 PRESSURE SWITCH
GFB 2 PRESSURE SWITCH
PURGE B
PURGE A
NOT USED
654321
BLACKREDBLACKREDBLACKRED
DUMP A
NOT USED
PURGE C
MANIFOLD654321
BLACKREDBLACKREDBLACKRED
DUMP B
GFB #1
GFB #2
12
VDC
3-W
AY SO
LENO
ID
J15
J8
12
VDC
4-W
AY SO
LENO
ID
123456
J12
J13
123456
UNUSEDUNUSEDUNUSEDUNUSEDUNUSEDUNUSED
GROUNDTERMINAL
50' STD.
123456
+12VDC COM
+12VDC COM
+12VDC COM
MANIFOLD
123456
+12VDC COM
+12VDC COM
+12VDC COM
123456
+12VDC COM
+12VDC COM
+12VDC COM
1 4 5 2 3
MANIFOLD654321
COM+12VDC
COM+12VDC
COM+12VDC
COM
+12VDC COM
+12VDC COM
+12VDC
COM+12VDC
COM+12VDC
COM+12VDC
654321
654321
CLR 12
CAT 4
CAT 3
CAT 2
CAT 1
SOL CAT
CLR 8
CLR 7
CLR 6
CLR 5
CLR 4
CLR 3
CLR 2
CLR 1
SOL CLR
COLORBOARD 2(COLORS13 THRU 30)
CLR 22
CLR 23
CLR 24
123456
+12VDC COM
+12VDC COM
+12VDC COM
MANIFOLD
123456
+12VDC COM
+12VDC COM
+12VDC COM
123456
+12VDC COM
+12VDC COM
+12VDC COM
MANIFOLD654321
COM+12VDC
COM+12VDC
COM+12VDC
COM
+12VDC COM
+12VDC COM
+12VDC
COM+12VDC
COM+12VDC
COM+12VDC
654321
654321
CLR 25
CLR 26
CLR 27
CLR 28
CLR 29
CLR 30
CLR 21
CLR 20
CLR 19
CLR 18
CLR 17
CLR 16
CLR 15
CLR 14
CLR 13
J8
J8
J15
J15
J14
J14
J9
J9
J16
J10
J10
J16
J4
J6
J7
J7/J11
J7/J11
Parts
14 312786J
Parts
15V821 Dump Valve Kit for Wall Panel
* Parts included in 16A079 Dump Valve Replacement Kit (purchase separately).
† Order Kit 16A560 to replace a single seat. The kit includes a seat (11) and o-rings (4 and 14).
NOTE: The standard valve seat (11) is SST. To install a carbide seat, order Kit 24U054. The kit includes a single carbide seat and o-rings 4 and 14.
Parts labeled n/a are not available separately.
TI12742b
1*
*2
*4
6
8
*11
12
TI13116a
9
A B
13
7
18
*14
15
19
Ref. No. Part No. Description Qty1* 24W310 VALVE, dispense; includes 14; see
manual 3127821
2* 17X718 ADAPTER, dump valve 14*† 111457 O-RING; ptfe 16 114342 ELBOW; 1/4 npt (mbe) 17 n/a TUBE; nylon; 5/32 in. (4 mm) OD;
2 ft (0.61 m)1
8* n/a NUT, hex; 9/16-18 19 121324 VALVE, solenoid, dump valve 111*† n/a SEAT, dump valve; sst 1
12 206966 HOSE; 1-1/2 ft (0.46 m) 113 111328 CONNECTOR; 10-32 x 5/32 in. (4
mm) OD tube1
14*† n/a O-RING; ptfe 115 101970 PLUG 118 166866 ELBOW, street; 1/4 npt (m x f) 119 C20482 NIPPLE; 1/4 npt 1
Ref. No. Part No. Description Qty
Parts
312786J 15
17L060 Dump Valve Kit for Wall Panel
* Parts included in 17P788 Dump Valve Replacement Kit (purchase separately).
† Order Kit 26A035 to replace a single seat. The kit includes a seat (11) and o-rings (4 and 14).
Parts labeled n/a are not available separately.
TI12742c
1*
*2
*4
6
8
*11
12
TI13116a
9
A B
13
7
17
*14
15
6
Ref. No. Part No. Description Qty1* 26A016 VALVE, dispense; includes 14; see
manual 3127821
2* 15T717 ADAPTER, dump valve 14*† 111457 O-RING; ptfe 16 114342 ELBOW; 1/4 npt (mbe) 27 n/a TUBE; nylon; 5/32 in. (4 mm) OD;
2 ft (0.61 m)2
8* 121569 NUT, hex; 9/16-18 19 121324 VALVE, solenoid, .25W 111*† n/a SEAT, dump valve; PEEK 1
12 24N345 HOSE; 1-1/2 ft (0.46 m) 113 111328 CONNECTOR; 10-32 x 5/32 in. (4
mm) OD tube1
14*† n/a O-RING; ptfe 115 101970 PLUG 117 17K624 FITTING, SWIVEL; 1/4 npt 119 C20482 NIPPLE; 1/4 npt 1
Ref. No. Part No. Description Qty
Parts
16 312786J
15V354 Third Flush Valve Kit for Wall Panel
‡ Parts included in Valve Seat Kit 2eparately.4A861 (purchase separately).
Parts labeled n/a are not available s
2 ‡4
8
1
3
5
‡6
6
7
910
‡11
TI12953a
TI12652a12 15
Ref. No. Part No. Description Qty1 15U673 BLOCK, double valve mount 12 15X303 VALVE, dispense; includes item 4;
see manual 3127821
3 15T600 ADAPTER, valve 14‡ n/a O-RING; ptfe 25 101970 PLUG, pipe; 1/4 npt 36‡ 109450 O-RING; ptfe 57 n/a SCREW, cap, socket-hd; 5/16-24 x
3/4 in. (19 mm)2
8 109031 SCREW, cap, socket-hd; 5/16-24 x 1 in. (25 mm)
2
9 166866 ELBOW, street; 1/4 npt (m x f) 110 501867 VALVE, check 1
11‡ n/a SEAT, valve 112 121374 VALVE, solenoid, 4-way 113 n/a TUBE; nylon; 5/32 in. (4 mm) OD; 3
ft (0.9 m); green1
14 n/a TUBE; nylon; 5/32 in. (4 mm) OD; 3 ft (0.9 m); red
1
15 114263 CONNECTOR; 1/8 npt(m) x 5/32 in. (4 mm) OD tube
2
Ref. No. Part No. Description Qty
Parts
312786J 17
15V822 Dump Valve Kit for RoboMix
Parts labeled n/a are not available separately.
TI13045a
TI12655a
Dump Valve A
DumpValve B
TI13047a
4
11
9
1
10
2 36
5
8
Ref. No. Part No. Description Qty1 15X304 VALVE, dispense; includes item
10; see manual 3127821
2 15V888 RETAINER, seat, RoboMix 13 15U713 VALVE, adapter; RoboMix 14 121795 VALVE, solenoid, 4-way 15 15U720 HOSE; 1/4 npt (mbe); 15-1/2 in.
(394 mm); ptfe1
6 114339 UNION, swivel; 1/4 npt 18 114446 ELBOW; 1/4 npt(m) x 1/4 npsm(f) 19 166421 NIPPLE; 1/4 npt 110 n/a O-RING; ptfe 1
11 C19979 SCREW, cap, socket-hd; 10-24 x 3/8 in. (10 mm)
4
12 111328 CONNECTOR; 10-32 x 5/32 in. (4 mm) OD tube
1
13 n/a TUBE; nylon; 5/32 in. (4 mm) OD; 3 ft (0.9 m); green
1
14 114342 ELBOW; 1/4 npt (mbe) 115 104644 PLUG, screw 116 104640 GASKET; buna-N 1
Ref. No. Part No. Description Qty
Parts
18 312786J
15V202 Third Flush Valve Kit for RoboMix
Parts labeled n/a are not available separately.
TI12655a
TI13047aTI13046a
5
6
1
10
32
4
8
9
Ref. No. Part No. Description Qty1 15V888 RETAINER, seat, RoboMix 12 109450 O-RING; ptfe 13 15U715 VALVE, adapter; RoboMix 14 501867 VALVE, check 15 15X304 VALVE, dispense; includes item 6;
see manual 3127821
6 n/a O-RING; ptfe 28 121795 VALVE, solenoid, 4-way 19 111328 CONNECTOR; 10-32 x 5/32 in. (4
mm) OD tube1
10 110420 SCREW, cap, socket-hd; 10-24 x 1-1/2 in. (38 mm)
4
13 n/a TUBE; nylon; 5/32 in. (4 mm) OD; 2 ft (0.61 m); green
1
Parts
312786J 19
15X247 Auto Dump Valve Kit
† Order Kit 16A560 to replace a single seat. The kit includes a seat (6) and o-rings (3 and 7).
NOTE: The standard valve seat (6) is SST. To install a carbide seat, order Kit 24U054. The kit includes a single carbide seat and o-rings 3 and 7.
Parts labeled n/a are not available separately.
TI14283a
1
2
3
6
TI13116a
5
9
4
7
8
GFB
1G
FB2
Ref. No. Part No. Description Qty1 24W310 VALVE, dispense; includes 7 ; see manual 312782 12 17X718 ADAPTER, dump valve 13† 111457 O-RING; ptfe 14 n/a TUBE; nylon; 5/32 in. (4 mm) OD; 5 ft (1.52 m) 15 121324 VALVE, solenoid, dump valve 16† n/a SEAT, dump valve; sst 17† n/a O-RING; ptfe 18 C20482 NIPPLE; 1/4 npt 19 111328 CONNECTOR; 10-32 x 5/32 in. (4 mm) OD tube 1
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 312786
Graco Headquarters: MinneapolisInternational Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS, MN 55440-1441 • USACopyright 2008, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.comRevision J, June 2018
Graco Standard WarrantyGraco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERSThe Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information For the latest information about Graco products, visit www.graco.com.
For patent information, see www.graco.com/patents.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505