25 tia portal v11 communication rela0 en

22
For internal use only / © Siemens AG 2011. All Rights Reserved. TIA Portal V11 Communication

Upload: christopher-t-caniedo

Post on 25-Aug-2014

783 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.

TIA Portal V11

Communication

Page 2: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.

Safety

OUC

CP-Connections

General

TIA Portal V11

Page 3: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 3 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Available communication protocols

S7-CommunicationGlobal data communications

MPI Ethernet

PROFIBUS

S7-CommunicationS7-1200 (NEW)

via CM 1243-5 (DP Master)Server/Client with PUT/GET

FDL-CommunicationFMS-Communication

S7-CommunicationS7-1200 (NEW)

via Onboard PN-InterfaceServer/Client with PUT/GET

configured connections (CP for S7-300/400)ISO, TCP, ISO-on-TCP, UDP

Open User Communication (T-Blocks)S7-1200 (with wizard)TCP, ISO-on-TCP, UDP (NEW)S7-300/400 (Wizard with SP1)TCP, ISO-on-TCP, UDP

Legend:

available

not available

limited

Page 4: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.

Safety

OUC

CP-Connections

General

TIA Portal V11

Page 5: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 5 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Creation of new connections

Procedure:Select the connection viewSelect the connection typeCreate the connection via

Drag & DropConnection tableMenu & Selection dialog

All possible connection partners are highlighted

Drag&Drop

Available connection partners

Possible connection interfaces

If there is currently no subnet, one is automatically

createdUnspecified connection

Connection view

Page 6: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 6 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

01010101010101010101010101010101010101010

Connection highlighting Highlighting of connectionsSelection via subnet mouse-over

PROFINET subnet≙ physical connection

Connection≙ communication

Configured connections

Connection Overview TableDepending on the selection, the table shows one or multiple devices

Page 7: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 7 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Connection properties

Connection properties:InterfaceLocal IDsSpecial connection propertiesAddress detailse.g. IP-addresses, ports, …

Page 8: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 8 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Call of communication blocks

Procedure:Select the communication blocks(from the Instruction-Taskcard)Assign like STEP 7 Classic blocks

Use the connection-ID (from the connection properties)Use the Hardware address (LADDR) (from the device properties)

Page 9: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.

Safety

OUC

CP-Connections

General

TIA Portal V11

Page 10: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 10 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Open User Communication (OUC)

To Know:An OUC-connection is programmedThe connection parameters will be stored in DBs(Same structure as in STEP 7 Classic)Thereby it is possible to change the connection parameters during runtimeA wizard supports the creation of the connection (Currently only for S7-1200; available first with S7-300/400 SP1)

Page 11: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 11 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Open User Communication (OUC)

Blocks without connection-management„TCON „ Establish connection„TDISCON“ Disconnect connection„TSEND“ & „TRCV“ Send data & receive data (TCP & ISO-on-TCP)„TUSEND“ & „TURCV“ Send data & receive data (UDP)

Blocks with automatic connection-management (only S7-1200)„TSEND_C“ Establish connection and send data„TRCV_C“ Establish connections and receive data

Page 12: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 12 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Without automatic connection-management

CPU 1 (active)

Connect

Connectiondata

IP addressConnection-IDTSAP/PORT

IE P

ort

TSENDSFB

TCONSFB

TDISCONSFB

TRCVSFB

CPU 2 (passive)

Connectiondata

IP addressConnection-IDTSAP/PORT

IE P

ort

TRCVSFB

TCONSFB

TDISCONSFB

TSENDSFB

Disconnect

Data

Data

Page 13: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 13 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

With automatic connection - management

CPU 1 (aktive)Connect

Connection-data

IP addressConnection-IDTSAP/PORT

IE P

ort

TSEND_CSFB

TRCV_CSFB

CPU 2 (passive)

Connectiondata

IP addressConnection-IDTSAP/PORT

IE P

ort

TRCV_CSFB

TSEND_CSFB

Data

Disconnect *

Connect

Data

Disconnect*

* Verbindung trennen / halten kann parametriert werden

Page 14: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 14 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Creation of OUC-Connections (S7-1200)

Procedure:Insert communicationblocksConfigure connection parameters in the wizard (property window)Assign block parameters

Activation of Online-Connection-Diagnostics

The wizard is found in the editor property window

Page 15: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 15 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Connection parameter configuration

Procedure:Select the communication partner:

Device in the same projectNot specified (e.g. PC)

Select the connection type(TCP, ISO-on-TCP or UDP)Setup the Connection-IDSelect storage location (DB)for connection dataSetup the address details (e.g. TSAP-ID or Port-No.)

All connection partners within the project are displayed hereIf a connection between the communication partners doesn‘t exist, one will be automatically created

Creation of a new DB or selection of an existing DB

Page 16: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 16 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Connection data

The connection data is stored in the system blocks folder

Same structure as STEP 7 Classic

Page 17: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 17 2011-09-22 TIA Portal V11 - Communication

Open User Communication (OUC)

Live Demo procedure

Create two S7-1200 devices

Call „TSEND_C“ in device 1

Configure device 1 connection

Call „TRCV_C“ in device 2

Configure device 2 connection

Page 18: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.

Safety

OUC

CP-Connections

General

TIA Portal V11

Page 19: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 19 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Engineering and programming communications

Which possibilities exist for safety communication?

-Industrial EthernetCPU-CPU-Communication to S7 Distributed Safety resp. S7 F Systems

-Industrial EthernetCPU-CPU-Communication via S7-Connection

IE/PB-LinkPROFINET IO and PROFIBUS DPIO-Controller-I-Slave-Communication

-PROFINET IOIO-Controller-I-Device-Communication

PN/PN CouplerPROFINET IOIO-Controller-IO-Controller-Communication

-PROFIBUS DPI-Slave-I-Slave-Communication

-PROFIBUS DPMaster-I-Slave-Communication

DP/DP-CouplerPROFIBUS DPMaster-Master-Communication

Safety CPU-CPU-Communication:-PROFIBUS DPI-Slave-Slave-Communication

Additional hardware requiredSubnetSafety communication

Page 20: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 20 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Safety communication PROFIBUS DP

Which possibilities exist for PROFIBUS DP communication?

A: Master – MasterB: Master – I-SlaveC: I-Slave – I-SlaveD: I-Slave – Slave

Page 21: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.I IA AS CS2 FAPage 21 2011-09-22 TIA Portal V11 - Communication

Safety

OUC

CP-Connections

General

Safety communication PROFINET IO

Which possibilities exist for PROFINET IO communication?

A: IO-Controller –IO-Controller

B: IO-Controller –I-Device

C: IO-Controller –I-Slave

D: I-Slave –I-Slave

Page 22: 25 TIA Portal V11 Communication RelA0 En

For internal use only / © Siemens AG 2011. All Rights Reserved.

I IA AS CS 2 FA

Gleiwitzerstr.55590475 Nürnberg

Phone: +49 (911) 895 - 4646

E-Mail: [email protected]