2016 title 24, part 6 - rebuild green expo

43
This program is funded by California utility customers under the auspices of the California Public Utilities Commission and in support of the California Energy Commission. Rebuilding Under the Energy Code 2016 Title 24, Part 6 Gina Rodda [email protected] (510) 428-0803

Upload: others

Post on 04-Jun-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2016 Title 24, Part 6 - Rebuild Green Expo

This program is funded by California utility customers under the auspices of the California Public Utilities Commission and in support of the California Energy Commission.

Rebuilding Under the Energy Code

2016 Title 24, Part 6

Gina [email protected](510) 428-0803

Page 2: 2016 Title 24, Part 6 - Rebuild Green Expo

Brought to you by…

California Statewide Codes & Standards

This program is funded by California utility customers under the auspices of the California Public Utilities Commission and in support of the California Energy Commission.

Page 3: 2016 Title 24, Part 6 - Rebuild Green Expo

Image courtesy of RDH Building Science 3

Let’s Bring the Energy Code to LIFE!

Page 4: 2016 Title 24, Part 6 - Rebuild Green Expo

Easy-to-use Energy Code Ace tools help you identify the forms, installation techniques, and standards relevant to building projects in California

Resources such as Fact Sheets, Trigger Sheets and Checklists, help you understand how and when to comply with California’s building and appliance energy efficiency standards

www.EnergyCodeAce.comThis program is funded by California utility customers under the auspices of the California Public Utilities Commission and in support of the California Energy Commission.

Targeted classroom and online trainings on Title 24, Part 6 and Title 20 address various stakeholders and measures

A website developed by the Statewide Codes & Standards Program to help you meet the requirements of Title 24, Part 6 and Title 20

We offer FREE

Page 5: 2016 Title 24, Part 6 - Rebuild Green Expo

EnergyCodeAce.com/resources 5

Page 6: 2016 Title 24, Part 6 - Rebuild Green Expo

Intent Behind the Code

6

How?

The Warren-Alquist Act, requires the Energy Commission to develop and maintain energy efficiency standards that are

“… cost effective, when taken in their entirety, and when amortized over the economic life of the structure when compared with historic practice”.

Time Dependent Valuation (TDV)

Gives greater weight to energy saved during peak periods – or periods when the generation capacity is at its limit and when the distribution system is near capacity.

http://www.energy.ca.gov/title24/2016standards/rulemaking/documents/2015-06-10_hearing/2015-06-10_Adoption_Hearing_Presentation.pdf

Page 7: 2016 Title 24, Part 6 - Rebuild Green Expo

Hot/Cold Climate Zones Mild Climate Zones

Prescriptive Package A: §150.1

7

Page 8: 2016 Title 24, Part 6 - Rebuild Green Expo

Warren Alquist Act: Energy Code to become more energy stringent every 3 years

AB 32 “Global Warming Solutions Act” moved us in the direction to use building efficiency to reduce energy use

SB 350 “Clean Energy and Pollution Reduction Act” sets the goal to double energy efficiency savings by 2030

Energy Code Evolution

Why?

8

Page 9: 2016 Title 24, Part 6 - Rebuild Green Expo

Jan. 2017- Dec. 2019 Jan. 2020- Dec. 2023

Which Code Year Applies? Permit pulled….

9

Page 10: 2016 Title 24, Part 6 - Rebuild Green Expo

Attics

Page 11: 2016 Title 24, Part 6 - Rebuild Green Expo

High Performance Attic: Intent

11

High Performance Attics (HPA) is a package of measures that minimizes the temperature difference between the attic and the conditioned air in ducts.

Page 12: 2016 Title 24, Part 6 - Rebuild Green Expo

High Performance Attic: Evolution

CZ 1-10: R-30 CZ 11-16: R-38

Option A Option BCZ 1-2/4/8-16: R-38CZ 3/5-7: R-30

CZ 1-3/6-7: nothingCZ 4/8-16: R-8

CZ 1-2/4/8-16: R-38CZ 3/5-7: R-30

CZ 1-3/6-7: nothingCZ 4/8-16: R-18

*No air space

CZ 1-3/6-7: nothingCZ 4/8-16: R-19

Page 13: 2016 Title 24, Part 6 - Rebuild Green Expo

13

Below Roof Deck Insulation Options

Page 14: 2016 Title 24, Part 6 - Rebuild Green Expo

-10%

-9%

-8%

-7%

-6%

-5%

-4%

-3%

-2%

-1%

0%

-10%

-1%

-6%

CZ 2 CZ 3 CZ 12Non HPA -10% -1% -6%

0

0.01

0.02

0.03

0.04

0.05

0.06

0.07

0.08

2%

4%

8%

CZ 2 CZ 3 CZ 12Column1HPA 2% 4% 8%

14

Compliance Impact

-10%

-8%

-6%

-4%

-2%

0%

2%

4%

6%

8%

-10%

-1%

-6%

2%

4%

8%

CZ 2 CZ 3 CZ 12Non HPA -10% -1% -6%HPA 2% 4% 8%

Page 15: 2016 Title 24, Part 6 - Rebuild Green Expo

Walls and Windows

Page 16: 2016 Title 24, Part 6 - Rebuild Green Expo

High Performance Wall: Intent

16

The Residential High Performance Walls measure is intended to increase the performance of the residential envelope, reducing the amount of heat transfer through walls and thus reduce HVAC loads.

The most common thermal bridges in residential buildings are from the framing members. In wood framed construction, the framing, while not highly conductive, still provide less thermal resistance than common cavity insulation materialsand therefore reduces the effective thermal resistance of the wall assembly.Buyers Guide to Continuous Insulation; Written by Building Science Corporation for Dow

Page 17: 2016 Title 24, Part 6 - Rebuild Green Expo

High Performance Wall: Evolution

17

Cavity insulation

U-factor: 0.051 (2 x 6 with R-19 + R-5)*

U-factor: 0.048 (2 x 6 with R-21 + R-5)*

*0.065 in CZ 6 and 7 (2 x 4 with R-15 + R-4)

Page 18: 2016 Title 24, Part 6 - Rebuild Green Expo

18

High Performance Wall Options

Page 19: 2016 Title 24, Part 6 - Rebuild Green Expo

-9%

-8%

-7%

-6%

-5%

-4%

-3%

-2%

-1%

0%

-9%

-1% -1%

CZ 2 CZ 3 CZ 122x4 R-15 -9% -1% -1%

0

0.02

0.04

0.06

0.08

0.1

0.12

0.14

2%

13%

14%

CZ 2 CZ 3 CZ 12Column22x6 R-21 and R-4 2% 13% 14%

19

Compliance Impact

-10%

-5%

0%

5%

10%

15%

-9%

-1% -1%

2%

13%14%

CZ 2 CZ 3 CZ 122x4 R-15 -9% -1% -1%2x6 R-21 and R-4 2% 13% 14%

Page 20: 2016 Title 24, Part 6 - Rebuild Green Expo

High Performance Window: Intent

20

Fenestration has a significant impact on heating and cooling loads in a home.

The size, orientation, and types of fenestration products can dramatically affect the overall energy performance of a house.

Fenestration area limitations, some of which is dependent upon orientation.

Products expected to be NFRC rated verifying performance of product.

Page 21: 2016 Title 24, Part 6 - Rebuild Green Expo

U-Factor: Ability of the window to prevent heat transfer

Fenestration Performance

21

Dual Paned

U-factor = 0.32NFRC Rated dualpaned nonmetal product

Tinted

SHGC= 0.25*NFRC Rated Low-e3

product

SHGC: Ability of the window to prevent solar heat

gain when sun hitting window

*excluding CZ 1,3,5 and 16 in 2019 code

SHGC= 0.23* U-factor = 0.30

Page 22: 2016 Title 24, Part 6 - Rebuild Green Expo

20% vertical fenestration area to conditioned floor area 2,000 sq. ft. home = 400 sq. ft. of glass window and/or glass

doors

5% West* facing fenestration area to conditioned floor area 2,000 sq. ft. home = 100 sq. ft. of facing west*excluding CZ 1,3,5

How Much?Fenestration Area

22

We look at energy use as a “TDV” evaluation:

What Time is the energy being used,

Dependent on where the building is located,

And looking at the Value of the energy source required.

Page 23: 2016 Title 24, Part 6 - Rebuild Green Expo

Mechanical Systems

Page 24: 2016 Title 24, Part 6 - Rebuild Green Expo

What Can Go Wrong?

24

Not enough airflow14% Ducts located in BAD

locations12%

Refrigerant charge losses

8%

Duct Leakage7%

Bad supply/return grille locations

5%Equipment Oversizing

4%

The heated/cooled air

actually got there!50%

Not enough airflowDucts in BAD placesRefrigerant chargeDuct leakage

Page 25: 2016 Title 24, Part 6 - Rebuild Green Expo

Required verification of:

Duct Leakage

AC equipment: Cooling Airflow Fan watt draw Refrigerant charge

Ventilation

HERS (Home Energy Rating System)

25

Extra Credit

Ducts in conditioned space

Verification of high efficiency HVAC equipment

Quality Insulation Installation (QII)

Page 26: 2016 Title 24, Part 6 - Rebuild Green Expo

On-demand tankless gas unit If natural gas available in

neighborhood

Minimize the Wait

Domestic Hot Water

26

High Efficiency heat pump water heater

Improvements required to design to allow for this (such as): PV system Solar hot water system

CZ 2-15: NEEA Tier 3CZ 1 & 16: “ + 0.3kWdc of PV

Page 27: 2016 Title 24, Part 6 - Rebuild Green Expo

EnergyCodeAce.com/resources 27

Page 28: 2016 Title 24, Part 6 - Rebuild Green Expo

Lighting and PV

Page 29: 2016 Title 24, Part 6 - Rebuild Green Expo

Lighting & PV

29

Fixtures

High efficacy

JA8-2016

Recessed cans

Controls

Room type

Fixture type

Under cabinet lighting switched

separately

Bulb to be JA8-2016Cannot be

screw based

JA8-2016 = dimmer or vacancyFluorescent = any type of switch

Page 30: 2016 Title 24, Part 6 - Rebuild Green Expo

The PV System Credit is available only if:

The Performance Approach is used

The project is in:

Climate Zones 1-5, 8-16

The system is:

≥ 2 kWdc* for Single Family

≥ 1 kWdc* for Multi Family

The amount of credit will depend upon the Climate Zone and the Conditioned Floor Area of the dwelling.

PV Credit

Residential PV Systems

* kilowatts direct currentA typical 1kWdc system often has approximately four PV panels

PV Required

Page 31: 2016 Title 24, Part 6 - Rebuild Green Expo

0%

5%

10%

15%

20%

25%

9%8%

21%

CZ 2 CZ 3 CZ 122 KW PV 9% 8% 21%

31

Compliance Impact

0%

5%

10%

15%

20%

25%

9%8%

21%

9%8%

21%

CZ 2 CZ 3 CZ 122 KW PV 9% 8% 21%10 KW PV 9% 8% 21%

Page 32: 2016 Title 24, Part 6 - Rebuild Green Expo

Moving Forward

Page 33: 2016 Title 24, Part 6 - Rebuild Green Expo

Other ECA Resources

33

Quick reference component-by-component summaries of sections of Title 24, Part 6 "triggered" based on project scope.

Quick reference summaries of key requirements, forms, definitions and resources for implementing Title 24, Part 6 and Title 20

Step-by-step guidance for plans checks and field inspections

Short manuals including compliance requirements and recommendations for implementing Title 24, Part 6 in new construction, addition and renovation projects.

Page 34: 2016 Title 24, Part 6 - Rebuild Green Expo

EnergyCodeAce.com/resources 34

Page 35: 2016 Title 24, Part 6 - Rebuild Green Expo

35

Application Guides:Short manuals including

compliance requirements and recommendations for

implementing Title 24, Part 6 in new construction, addition and

renovation projects.

Available through Amazon

Page 36: 2016 Title 24, Part 6 - Rebuild Green Expo

Decoding Talks

36

Last Decoding Talk…

Next Decoding Talk…

Page 37: 2016 Title 24, Part 6 - Rebuild Green Expo

Workforce Instruction for Standards and Efficiency (WISE)

www.wisewarehouse.org

A training and education program sponsored by the California Energy Commission.

Curates HPA/HPW technical resources and product information on website

Provides FREE in-person, one-on-one trainings to the CA building industry on overcoming barriers to HPA/HPW implementation.

Contact Dan Krekelberg, WISE Program Manager [email protected]

Page 38: 2016 Title 24, Part 6 - Rebuild Green Expo

www.energycodeace.com

Our goal is to make YOUthe energy expert.

38Questions?

Page 39: 2016 Title 24, Part 6 - Rebuild Green Expo

2016 Title 24, Part 6 - Residential Recover & Rebuild Page 1 of 2 2018-01-26

Residential

Recover & Rebuild

Energy Code AceHelping you play your cards right

AceResources

Title 24, Part 6

Fact Sheet2016 ENERGY CODE

California’s Building Energy Code (also known as Title 24, Part 6) enables homeowners to save on their electricity and natural gas bills - and by reducing greenhouse gas emissions, helps the environment. If your home needs to be repaired or rebuilt, you may need to comply with this code. This fact sheet includes basic information on the code, but please contact us at [email protected] if you would like additional assistance.

When is the Building Energy Code Triggered?Alteration: The home is damaged and part(s) of the home require reconstruction (e.g., new roof being installed to replace a damaged roof).Addition: The home is being added onto, and the habitable floor area increases (e.g., adding a new family room to the back of an existing house). New Home: The home must be completely rebuilt.

What Doesn’t Trigger the Building Energy Code? A repair does not trigger the Building Energy Code. This is the reconstruction of a building component that does not increase the preexisting energy consumption of that repaired feature. For example, replacing glass in a window is a repair, but replacing the glass and framing of a window is considered an alteration.

AlterationsEnvelope: All walls, floors and roofs must be insulated (even if not previously installed) when opened up (made accessible), or rebuilt in the same exact location, to the minimum insulation requirements of the Building Energy Code. New roofing may need to be a Cool Roof Rating Council (CRRC)-certified cool roof product depending on where the home is located (climate zones 10-15). Title 24, Part 6 Sections 150.0(a-d)Windows/Glass Doors/Skylights (Fenestration): Replaced fenestration totaling 75 ft2 or more, must meet the same requirements of a new home, but if under 75 ft2 is being replaced, there are some exceptions. Title 24, Part 6 Sections 150.0(o)/150.2(b)1A/B/GHeating/AC/Ventilation (HVAC)/Water Heater: Replaced mechanical system type(s) can match what was there before. New or replaced heating and/or cooling systems require a third-party HERS Rater to test and verify that certain components were installed properly. Title 24, Part 6 Sections 150.0(h-j)(m-o)/150.2(b)C-FLighting: Replaced or new lighting must be “high efficacy,” which is essentially fluorescent technology or LED that meets quality control requirements (Title 24 Reference Joint Appendix JA8). No screw-based recessed can lights are allowed. In addition, there are simple lighting control requirements. The lighting requirements apply equally to alterations, additions and new construction. Title 24, Part 6 Section 150.0(k)

AdditionEnvelope: All new walls, floors and roofs must meet similar requirements of a new home, but with some exceptions dependent on the square footage of the addition or if considered an “extended” wall. Title 24, Part 6 Sections 150.2(a)1 and 2Windows/Glass Doors/Skylights (Fenestration): There are performance requirements of fenestration product, such as U-Factor (resistance to heat transfer) and SHGC (Solar Heat Gain Coefficient, the ability to limit heat gain into the home from the sun). In addition, there are limitations to the amount of fenestration being used, dependent on the square footage of the addition. Title 24, Part 6 Section 150.2(a)HVAC/Water Heater: New HVAC system(s) have the same requirements as those being installed in a new home. A new tankless gas water heater (minimum efficiency) may be added as part of an addition (exceptions may apply). Title 24, Part 6 Sections 150.0(h-j)(m-o)/ 150.2(a) and (b)Lighting: New lighting has the same requirements for all project types. Title 24, Part 6 Section 150.0(k)

Page 40: 2016 Title 24, Part 6 - Rebuild Green Expo

This program is funded by California utility customers under the auspices of the California Public Utilities Commission and in support of the California Energy Commission. © 2018 Pacific Gas and Electric Company, San Diego Gas and Electric, Southern California Gas Company and Southern California Edison. All rights reserved, except that this document may be used, copied, and distributed without modification. Neither PG&E, Sempra, nor SCE — nor any of their employees makes any warranty, express of implied; or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product, policy or process disclosed in this document; or represents that its use will not infringe any privately-owned rights including, but not limited to patents, trademarks or copyrights.

EnergyCodeAce.com 2016 Title 24, Part 6 - Residential Recover & Rebuild Page 2 of 2

New HomeEnvelope: New roof, wall and floor requirements will most likely exceed the building requirements in which the existing home was built. Title 24, Part 6 Section 150.1(c)Attics: Most areas in California have “high performance” attic requirements which typically means insulation placed on the ceiling AND another layer of insulation at the roof. Title 24, Part 6 Section 150.1(c)1AWalls: Most areas in California have “high performance” wall requirements which typically means 2”x 6” wood framing using R-19 insulation and an additional 1” of rigid insulation outside the framing. Title 24, Part 6 Section 150.1(c)1B Fenestration: New fenestration requirements dictate using National Fenestration Rating Council (NFRC)-rated dual-paned vinyl/wood/fiberglass products using Low-E3 glazing. In addition, there are limitations on the amount used in home. Title 24, Part 6 Section 150.1(c)3-4HVAC/Water Heater: HVAC system(s) will require third-party testing by a HERS Rater to verify certain components of the system(s). One gas tankless water heater meeting minimum efficiency. Title 24, Part 6 Sections 150.1(c)6-10 and 12-13Lighting: New lighting has the same requirements for all project types. Title 24, Part 6 Section 150.0(k)

For More InformationCalifornia Energy Commission Information & ServicesTitle 24, Part 6• Energy Standards Hotline: 1-800-772-3300 (Free) or

[email protected]• Online Resource Center:

energy.ca.gov/title24/orc/– The Energy Commission’s main web portal for Energy Standards,

including information, documents, and historical information• Home Energy Rating System (HERS) Program Sub-site:

energy.ca.gov/HERS/ • What is Your Home Energy Rating booklet

energy.ca.gov/HERS/booklet.html • California Building Climate Zone Map:

energy.ca.gov/maps/renewable/building_climate_zones.html

Additional Resources• National Fenestration Rating Council (NFRC):

nfrc.org/ – NFRC offerings can help facility managers, specifiers, designers

and others make informed purchasing and design decisions about fenestration products

• CRRC-Rated Products Directory: coolroofs.org/products/results – Search for rated roofing products

• Energy Code Ace: EnergyCodeAce.com

– An online “one-stop-shop” providing free resources and training to help appliance and building industry professionals decode and comply with Title 24, Part 6 and Title 20. The site is administered by California’s investor-owned utilities.

Of special interest: Application Guides • Residential Envelope and Solar Ready Areas • Residential HVAC and Plumbing • Residential Lighting energycodeace.com/content/resources-ace/file_type=application-

guide Fact Sheets • Nonresidential & Residential Permit Process 2016 • Just the Basics: HERS for Residential and

Nonresidential Projects • Quick Reference Sheet: HERS for Residential

and Nonresidential Projects 2016 • Quick Reference Sheets for Climate Zone

Compliance Baselines • Residential Cool Roofs • Residential Domestic Hot Water (DHW) • Residential Fenestration • Residential HVAC Alterations • Residential Lighting • Residential Opaque Envelopes • Title 20 Residential Pool Pump Motors energycodeace.com/content/resources-fact-sheets/ Trigger Sheets • Residential HVAC Alterations energycodeace.com/content/resources-ace/file_type=trigger-sheet

Please register with the site and select an industry role for your profile in order to receive messages about all our free offerings!

What methods can be used to show compliance with the Building Energy Code? In addition to mandatory measures (which must always be met), there are two methods:1. Prescriptive Method: All code requirements can be met or exceeded. Forms used: • Alterations: CF1R-ALT-01 through 04-E (or the CF1R-ALT-05-E if no HERS measures) • Additions: CF1R-ADD 01-E (or the CF1R-ADD-02-E if no HERS measures) • New Home: CF1R-NCB-01-E2. Performance Method: Flexibility is desired in place of the prescriptive code requirements. • CF1R-PRF-01-E is the form used for alteration/addition/new home.

Page 41: 2016 Title 24, Part 6 - Rebuild Green Expo

Insulation Guide

1 | P a g e

Insulation Material

R-value per inch

Appearance Advantages Disadvantages Product

Highlights Batt Type

Fiberglass 3-3.7

Readily available Must be installed

correctly to achieve full R-value

Widely available

Mineral Wool 2.8-3.7

Somewhat better fire resistance and

soundproofing than fiberglass;

Good for water drainage.

Same as fiberglass ROXUL

Cotton 3-3.7

Environmentally friendly

Not readily available; Installation

Ultra Touch

Loose Fill

Fiberglass 3-3.7

Easier to install correctly

Must be kept in place (insulation dams)

JM; Owens Corning

Boxed Netting Fiberglass

3-3.7

Below roof deck insulation;

Less expensive than spray insulation

More labor intensive than spray on insulation

Owens Corning Pro Pink High

Performance Attic System

Mineral Fiber 2.8-3.7

Easier to install correctly

Must be kept in place

(insulation dams)

Ecofill by Knauf Insulation

Cellulose Fiber 3-3.7

Provides more resistance to air

movement than other loose fill

Must be kept in place

(insulation dams)

Greenfiber; Green Seal from

FiberAmerica

Page 42: 2016 Title 24, Part 6 - Rebuild Green Expo

Insulation Guide

2 | P a g e

Insulation Material

R-value per inch

Appearance Advantages Disadvantages Product

Highlights Board Stock

Type I & II Expanded

Polystyrene or

EPS

3.6-4.4

Inexpensive HC's usually used in production. Must be

covered.

Cellofoam Polysheild

Type III & IV extruded

polystyrene or

XPS

4.5-5

Works well in wet conditions

HFC usually used in production. Must be

covered.

Owens Corning FOAMULAR

Rigid Fiberglass 4.2-4.5

Drains away water Not easily available Owens Corning FIBERGLASS

Rigid Mineral Fiber

4.2-4.5

Drains away water More expensive than

polystyrene Thermafiber;

ROXUL

Polyisocyanurate or ISO

5.6-6.7

Closed cell, high R-Values compared to

polystyrene

HFC usually used in production

RMAX

Expanded Polystyrene

Tile Roof Installation

Product

R-6 for product

Also helps support roof tile

Limited to tile roof construction

Wedge-it

Insulated Roof Tiles

R-7-14 for product

Insulation and

Roofing in One Replacement

EternaTile; Green Hybrid

Roofing;

Page 43: 2016 Title 24, Part 6 - Rebuild Green Expo

Insulation Guide

3 | P a g e

Insulation Material

R-value per inch

Appearance Advantages Disadvantages Product

Highlights Spray Applied

Wet Spray Cellulose 3-3.7

Low labor costs, environmental

benefits, fewer gaps

Adhesive mixed with insulation; must dry

before any other sub can enter space

any loose cellulose product fixed with water or adhesive

Spray -applied fiberglass insulation

4.2-4.3

Higher R-value than spray cellulose

Lower recycled content than typical spray

cellulose JM Spider

Open-cell Light Density

Polyurethane 3.6

Low labor costs Must be covered; more

expensive than batt Icynene; Demilec

Closed Cell Medium Density

Polyurethane 5.5-6

Can act as the air barrier and vapor

retarder.

HFC usually used in production. Must be

covered. Icynene; Demilec

Other

Structural Insulated Panel Systems

(SIPs)

depends on insulation

used

Quick installation, good thermal

performance and structural integrity

More expensive than alternatives; unfamiliar

to builders; building must be designed with

product in mind

Thermocore; Structural Insulated Panel Association

Exterior Insulation and Finish Systems

(Synthetic Stucco/EIFS)

depends on rigid

insulation used

Finish and continuous insulation in one

product

Special attention must be paid to drainage

detailing

EIFS Industry Members

Association (EIMA)

Insulating Concrete

Form (ICFs)

depends on the details

of the ICF blocks

Fire resistant, durable and energy efficient

More expensive than alternatives; unfamiliar

to builders; building must be designed with

product in mind

Concrete.org: http://bit.ly/2FkqdDP

Image Credit: Mineral wool photo from Knauf Insulation Pink fiberglass winter wonderland (CC BY 2.0) by mikemol Tile Roof Insulation - Courtesy of CHP - Master Builder Advanced Home Design and Building Practices 2016 Code Readiness Program Insulating Concrete Form –FEMA News Photo Photo by Kent Baxter - Nov 22, 2001