2006trans13_b .doc SENSED PARAMETER FAULT CODE  ACCEPTABLE OPERATING RANGE AND RATIONALITY PRIMARY MALF DETECTION PARAMETERS SECONDARY PARAMETERS  AND CONDITIONS MONITORING TIME & DTC TYPE DEFAULT ACTIONS PRIMARY MALF PASS CONDITION SECONDARY PASS CONDITIONS TEST SETUP PROCEDURE COMMENTS Page 1 of 10  Trans mission Fluid Over Temperat ure P0218 High transmission fluid temperature for long period of time  Tra ns Tem p >13 0° C. 8.0V <Ignition Voltage <18.0V -39° C. <Trans Temp <149° C. for 5 sec 600 sec  Type C- Freeze adapt s FA  Tra ns Temp  12 9° C. for 5.0 sec Same as fail Key up and short a potentiometer between the  TFT Signal an d TFT GND on t he TCM side. Adjust t he temperature to 135°C and then key down. Start the engine.  TFT: 3 5 (AP)  TFT GND: 30 (AJ ) System Voltage Low P0562 Measured voltage at the TCM is a below an acceptable level System Voltage <11V Engine Speed >1200 rpm for 5 sec 10 seconds  Type C- None System Voltage >11V 10 sec Same as fail System Voltage High P0563 Measured voltage at the TCM is above an acceptable level System Voltage > 18V None 10 seconds  Type C- None System Voltage <18V 10 sec None  Trans mission Control Module Read Only Memory P0601 EPROM/Flash memory corruption (Incorrect program/calibrations checksum) ROM fail count >5 None Immediate  Type A Freeze adapt s Max line pressure  TCC forc ed of f Inhibit TCC solenoid Soft landing FATKO ROM fail count <5 None  Trans mission Control Module Not Programmed P0602 Non-programm ed  TCM ( calib rat ions ) KbCOND_NoStar tCal =  TRUE None Immediate  Type A Freeze adapt s Max line pressure  TCC fo rc ed of f Inhibit TCC solenoid Immediate Landing FATKO KbCOND_NoSt art Cal =FALSE None  Trans mission Control Module Long-Term Memor y Reset P0603 Wrong copy of Non- volatile Memory t o RAM Non-volatile memory (static or dynam ic) checksum failure None Immediate  Type A Freeze adapt s Max line pressure  TCC fo rc ed of f Inhibit TCC solenoid Soft landing FATKO Non-volatile memory (static or dynamic) checksum pass  Trans mission Control Module Random Access Memory P060 4 RAM failure RAM read/w rite failure (single word) RAM fail count >5 None Immediate  Type A Freeze adapt s Max line pressure  TCC fo rc ed of f Inhibit TCC solenoid Soft landing FATKO RAM read/w rite pass (all word s) RAM fail count <5

Upload: eurospeed2

Post on 03-Apr-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2006trans13_b

7/28/2019 2006trans13_b

http://slidepdf.com/reader/full/2006trans13b 1/10

2006trans13_b .doc

SENSED

PARAMETER  FAULT

CODE

 ACCEPTABLE

OPERATING

RANGE AND

RATIONALITY

PRIMARY MALF

DETECTION

PARAMETERS

SECONDARY PARAMETERS

 AND CONDITIONS  MONITORING

TIME & DTC

TYPE

DEFAULT ACTIONS PRIMARY

MALF PASS

CONDITION

SECONDARY

PASS

CONDITIONS

TEST S

PROCE

Page 1 of 10

 Transmission FluidOver Temperature

P0218 High transmissionfluid temperature forlong period of time

 Trans Temp >130° C. 8.0V <Ignition Voltage <18.0V-39° C. <Trans Temp <149° C. for

5 sec

600 sec

 Type C-

Freeze adaptsFA

 Trans Temp ≤ 129° C. for 5.0

sec

Same as fail Key up and shopotentiometer b

 TFT Signal andon the TCM sidtemperature to then key down.Start the engine

 TFT: 35 (AP) TFT GND: 30 (

System Voltage

Low

P0562 Measured voltage at

the TCM is a belowan acceptable level

System Voltage <11V Engine Speed >1200 rpm for 5 sec 10 seconds

 Type C-

None System Voltage

>11V10 sec

Same as fail

System VoltageHigh

P0563 Measured voltage atthe TCM is above anacceptable level

System Voltage >18V None 10 seconds Type C-

None System Voltage<18V10 sec

None

 TransmissionControl ModuleRead OnlyMemory

P0601 EPROM/Flashmemory corruption(Incorrectprogram/calibrationschecksum)

ROM fail count >5 None Immediate

 Type A

Freeze adaptsMax line pressure TCC forced off 

Inhibit TCC solenoidSoft landing

FATKO

ROM fail count<5

None

 TransmissionControl ModuleNot Programmed

P0602 Non-programmed TCM (calibrations)

KbCOND_NoStartCal = TRUE

None Immediate

 Type A

Freeze adaptsMax line pressure TCC forced off 

Inhibit TCC solenoidImmediate Landing

FATKO

KbCOND_NoStartCal =FALSE

None

 TransmissionControl ModuleLong-TermMemory Reset

P0603 Wrong copy of Non-volatile Memory toRAM

Non-volatile memory(static or dynamic)checksum failure

None Immediate

 Type A

Freeze adaptsMax line pressure TCC forced off 

Inhibit TCC solenoid

Soft landing

FATKO

Non-volatilememory (staticor dynamic)checksum pass

 TransmissionControl ModuleRandom AccessMemory

P0604 RAM failure RAM read/write failure(single word)

RAM fail count >5

None Immediate

 Type A

Freeze adaptsMax line pressure TCC forced off 

Inhibit TCC solenoidSoft landing

FATKO

RAM read/writepass (all words)

RAM fail count<5

Page 2: 2006trans13_b

7/28/2019 2006trans13_b

http://slidepdf.com/reader/full/2006trans13b 2/10

Page 3: 2006trans13_b

7/28/2019 2006trans13_b

http://slidepdf.com/reader/full/2006trans13b 3/10

Page 4: 2006trans13_b

7/28/2019 2006trans13_b

http://slidepdf.com/reader/full/2006trans13b 4/10

Page 5: 2006trans13_b

7/28/2019 2006trans13_b

http://slidepdf.com/reader/full/2006trans13b 5/10

Page 6: 2006trans13_b

7/28/2019 2006trans13_b

http://slidepdf.com/reader/full/2006trans13b 6/10

Page 7: 2006trans13_b

7/28/2019 2006trans13_b

http://slidepdf.com/reader/full/2006trans13b 7/10

Page 8: 2006trans13_b

7/28/2019 2006trans13_b

http://slidepdf.com/reader/full/2006trans13b 8/10

Page 9: 2006trans13_b

7/28/2019 2006trans13_b

http://slidepdf.com/reader/full/2006trans13b 9/10

Page 10: 2006trans13_b

7/28/2019 2006trans13_b

http://slidepdf.com/reader/full/2006trans13b 10/10

2006trans13_b .doc

SENSED

PARAMETER  FAULT

CODE

 ACCEPTABLE

OPERATING

RANGE AND

RATIONALITY

PRIMARY MALF

DETECTION

PARAMETERS

SECONDARY PARAMETERS

 AND CONDITIONS  MONITORING

TIME & DTC

TYPE

DEFAULT ACTIONS PRIMARY

MALF PASS

CONDITION

SECONDARY

PASS

CONDITIONS

TEST S

PROCE

Page 10 of 10

LostCommunicationwith BodyControlSystem(GMX001 ONLYGMT001 ONLY)

U0140  Communicationbetween TCM & BodyControl System Lost

CAN Bus BCM Error Flag=1

Ignition ON

8V <Ignition Voltage <18V for 5 seconds

Fail Count =12 out of 12(Time ≈ 12sec)

 Type C

None CAN Bus BCMError flag =0

Sample Count=12 (Time ≈ 12

sec)

Same as Fail Open the CAN CAN LO(1) signat exactly the sa

CAN HI(1): 7 (HCAN LO(1): 6 (