13 trefann street / i inspect three60 / frank bernardo€¦ · toronto ont m5a 3a9 i inspect...

32
Inspection Report Property Address: 13 Trefann Street Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Upload: others

Post on 20-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Inspection ReportProperty Address:13 Trefann Street

Toronto ONT M5A 3A9

I Inspect Three60

Frank Bernardo2343 Queen Street East

Toronto, OntarioM4E 1H2

(416) 347-5187

Page 2: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Table of Contents

Cover Page.................................................................1

Table of Contents ........................................................2

Intro Page ...................................................................3

1 Roofing.....................................................................6

2 Exterior.....................................................................8

3 Structural Components ............................................9

4 Insulation and Ventilation .......................................11

5 Interiors ..................................................................13

6 Electrical System ...................................................15

7 Plumbing System...................................................22

8 Heating / Central Air Conditioning..........................25

General Summary.....................................................31

I Inspect Three60

13 Trefann Street Page 2 of 32

Page 3: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Date: 2016-09-14 Time: 10:30 AMReport ID:091416FB13-TREFANN-ST-TORONTO-ON-M5A-3A9

Property:13 Trefann StreetToronto ONT M5A 3A9

Customer: Real Estate Professional:Aleksandra OleksakSage Real Estate Ltd.,Brokerage

Comment Key or Definitions

The following definitions of comment descriptions represent this inspection report. All comments by the inspector should beconsidered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a secondopinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair orreplacement of item, component or unit should be considered before you purchase the property.

Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to befunctioning as intended allowing for normal wear and tear.

Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it wasfunctioning as intended and will state a reason for not inspecting.

Not Present (NP) = This item, component or unit is not in this home or building.

Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by aqualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.

Every effort has been made to provide a comprehensive overview of this structure. However, minor details may have beeninadvertently overlooked. We sincerely regret any inconvenience these oversights may cause. The results of the inspectionfindings are as of the date and time of the inspection.

The inspection is not a building code compliant inspection. It may identify items which we feel are not up to current orexisting standards. However, we are not qualified to call them "defective" according to the "building code". The opinion ofthe local building official takes precedence. Building code interpretations must take into consideration the codes in place atthe time the work was completed or when the home was built. You may find that items need further evaluation or repairs andthere may be additional issues found than what was first identified. This is normal as a qualified contractor may need to domore repairs than what was first seen by the inspector. That is why we recommend further evaluation by qualified/licensedcontractors/technicians.

We do not quote repair or replacement costs. We suggest that you obtain pricing/estimates from local contractors or searchweb-sites to obtain "ball-park" repair costs for your buying decisions. An example of a web-site in Ontario iswww.ontariocontractors.com. Prior to closing and purchasing the property, we recommend obtaining estimates fromqualified contractors for items marked in the report as "repair" or "replace". This will provide you with additional informationincluding the cost to have items repaired or replaced.

There may be recommendations in this Inspection Report for further investigation of a specific component, whether forrepair, replacement or further evaluation. In such cases, it is strongly advised that you consult contractors licensed andinsured to inspect those specific items for repair, replacement or evaluation.

For repairs, replacements or recommendations identified in this report, it is recommended that qualified, licensedand insured trades/technicians are sourced (e.g.):

- Electrical - Licensed Electrical Contractor

- Plumbing - Qualified Plumber

- HVAC - Licensed HVAC Technician

- Structure - Licensed Structural Engineer

I Inspect Three60

13 Trefann Street Page 3 of 32

Page 4: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

- Foundations - Qualified Foundation Contractor/Licensed Structural Engineer

- Mold/Indoor Air Quality - Certified Technician/Remediation

- Asbestos - Certified Technician/Remediation

- General Home - Qualified Contractor

New Construction/Renovations:

- For new construction, renovations and updates (e.g. electrical, plumbing, structural), it is recommended to obtain andreview construction history and permits/certifications from Seller. Questions regarding code compliance should be addressedto the appropriate local officials.

Home Maintenance:

- Annual maintenance costs can run 1% to 3% of the sales price of a home, or higher. Considerations include age, design,prior construction and maintenance, etc. Home owners should plan and budget for regular and preventative maintenance.

Estimated Age of the House and Systems:

- Estimations reflect the inspectors' opinion as to the approximate age. Estimations are provided for general and guidancepurposes only.

Design Life:

- Stated design life is represented as a guide only. Design life estimates are based on industry guidelines.

Photos/Pictures:

- Photos do not necessarily reflect all conditions or issues, and is not provided to highlight or diminish the significance orseverity of defects or conditions. Please read the entire report for pertinent information.

Infrared Photos:

- If used in this report, infrared pictures reflect estimated temperature and conditions, and are for general reference only.

Recommendations:

- Recommendations in this report, specifically items rated "repair or replace", should be addressed as soon as possible.

Previous Repairs:

- Any references to previous repairs in this report, the Buyer should request/obtain the repair history from the Seller,including applicable permits/warranties.

Water Intrusion:

- Water intrusion in a home can be caused by near level or negative grading, aged or damaged shingles, deterioratedplumbing supply and drains, etc. Water intrusion can contribute to microbial activity or mold intrusion. Preventativemaintenance is a key part of maintaining a home including helping prevent water and mold intrusion. Areas identified in thisreport including possible water intrusion or to help prevent water intrusion, should be addressed as soon as possible.

Condo Associations:

Please check with the applicable associations to understand what you are responsible for and what the association isresponsible for.

This report is intended for use only by the party contracting for same. It is not intended to benefit any third party.

I Inspect Three60

13 Trefann Street Page 4 of 32

Page 5: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Each Global Property Inspections Franchise is Independently Owned and Operated

In Attendance:Vacant (inspector only)

Type of building:Single Family - Semi-Detached

Approximate age:100+ Years

Home Faces:West

Temperature:20'C

Weather:Light Rain

Ground/Soil surface condition:Dry

I Inspect Three60

13 Trefann Street Page 5 of 32

Page 6: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

1. RoofingThe home inspector shall observe: Roof covering; Roof drainage systems; Flashings; Skylights, Chimneys, and Roof penetrations; and signs of leaksor abnormal condensation on building components. The home inspector shall: Describe the type of roof covering materials; and Report the methodsused to observe the roofing. The home inspector is not required to: walk on the roofing; or observe attached accessories including but not limited tosolar systems, antennae, and lightning arrestors.

Preventative Maintenance Note - Downspouts: To help reduce the risk of water pooling around the foundation, it is recommended thatdownspouts are routed above ground 5 to 6' away from the foundation. Some municipalities restrict the use of in-ground downspouts connected tothe "city" system. Check and adhere to your local municipal by-laws.

Preventative Maintenance Note - Downspouts: To help reduce the risk of deterioration at the shingles, it is recommended that downspouts arerouted to the gutters, where the downspout terminates on the shingles.

Preventative Maintenance Note - Roofing/Flashing/Seals: To help reduce the risk of water intrusion, it is recommended to monitor roofing,flashing and seals on a regular basis. Ensure all nail-heads and flashing are properly sealed.

Items recommended for repair or replacement should be further evaluated and repaired or replaced by qualified/licensed and insuredcontractors (e.g. roofing contractor, masonry contractor)

Styles & Materials

Roof Covering:AsphaltArchitectural

% Roof Covering Visible:75%

Estimated # of Layers:1

Roof Covering Estimated Age - Sloped:2 - 3 Years

Roof Covering Estimated Design Life:Ashphalt Shingles: 20 - 25 Years

Roof Covering At or Near Its' DesignLife?:No

Viewed roof covering from:GroundEye-Stick (Wireless Camera)

Roof Covering Limitations:Limited observation due to rainLimited observation due to height/pitch

Chimney(Exterior):Composite Wood

Chimney Limitations:The chimney inspection is limited to theexterior only

Gutters & Downspouts:Aluminum

Soffit and Facia:AluminumWood

IN NI NP RR

1.0 Roof Coverings •

1.1 Flashings • •

1.2 Chimney(s) •

1.3 Roof Drainage Systems (Gutters/Downspouts) •

IN NI NP RRIN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

I Inspect Three60

13 Trefann Street Page 6 of 32

Page 7: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Comments:

The roof of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern,some areas can go unnoticed. Roof coverings and skylights can appear to be leak proof during inspection and weather conditions. Our inspectionmakes an attempt to find a leak but sometimes cannot. Please be aware that the inspector has your best interest in mind. Any repair items mentionedin this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issuesas it relates to the comments in this inspection report.

Roof covering, flashing and seals should be monitored regularly and repaired or replaced as required, to help reduce the risk of water/mold intrusion.

1.1 Preventative Maintenance Note:

There is an exposed area at the north side. Adding a flashing or sealing this area can prevent further deterioration/water intrusion.

Potential Risk: Water intrusion.

1.1 Item 1(Picture)

I Inspect Three60

13 Trefann Street Page 7 of 32

Page 8: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

2. ExteriorThe home inspector shall observe: Wall cladding, flashings, and trim; Entryway doors and a representative number of windows; Garage dooroperators; Decks, balconies, stoops, steps, areaways, porches and applicable railings; Eaves, soffits, and fascias; and Vegetation, grading, drainage,driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The home inspector shall: Describe wallcladding materials; Operate all entryway doors and a representative number of windows; Operate garage doors manually or by using permanentlyinstalled controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meetingreasonable resistance during closing; and Probe exterior wood components where deterioration is suspected. The home inspector is not required toobserve: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Fences; Presence of safety glazing in doorsand windows; Garage door operator remote control transmitters; Geological conditions; Soil conditions; Recreational facilities (including spas,saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detachedbuildings or structures; or Presence or condition of buried fuel storage tanks. The home inspector is not required to: Move personal items, panels,furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility.

Preventative Maintenance Note - Grading: I recommend to monitor grading on a regular basis (e.g. spring after the freeze/thaw season) to ensurethe grading slopes away from the foundation, to help reduce the risk of water pooling and water/mold intrusion.

Preventative Maintenance Note - Brick Siding: Hairline cracks are common at the brick siding of the house. Cracks should be properly assessedand sealed to help reduce the risk of further deterioration (e.g. water intrusion in the fall and winter season with the risk of freezing and expanding). Irecommend to monitor the exterior of the home regularly (e.g. spring) and evaluate/repair as required.

Items recommended for repair or replacement should be further evaluated and repaired or replaced by qualified/licensed and insuredcontractors/technicians.

Styles & Materials

Siding:Composite WoodCement-Fiber

Exterior Entry Doors:Steel

Windows:Vinyl

Driveway:Dirt

Walkway/Patio:BrickConcrete

Grading Limitations:Limited observation under rear addition

Deck/Balcony Limitations:Restricted observation under the deck area

IN NI NP RR

2.0 Grading/Drainage •

2.1 Driveway(s) •

2.2 Decks, Balconies, Porches, Patio/Cover, Walks/Steps and Railings •

2.3 Siding, Flashing, Trim and Vegetation •

2.4 Doors (Exterior) •

2.5 Windows •

2.6 Eaves, Soffits and Fascias •

IN NI NP RRIN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

The exterior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas ofconcern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.

I Inspect Three60

13 Trefann Street Page 8 of 32

Page 9: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

3. Structural ComponentsThe Home Inspector shall observe structural components including foundations, floors, walls, columns or piers, ceilings and roof. The home inspectorshall describe the type of Foundation, floor structure, wall structure, columns or piers, ceiling structure, roof structure. The home inspector shall:Probe structural components where deterioration is suspected; Enter under floor crawl spaces, basements, and attic spaces except when access isobstructed, when entry could damage the property, or when dangerous or adverse situations are suspected; Report the methods used to observeunder floor crawl spaces and attics; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmfulcondensation on building components. The home inspector is not required to: Enter any area or perform any procedure that may damage theproperty or its components or be dangerous to or adversely effect the health of the home inspector or other persons.

Potential Risk Note: Hairline cracks at the basement floor is a common occurrence. It is recommended to properly seal cracks to help reduce therisk of heating/cooling loss, and possible hazardous "gases" leaking into the living space (e.g. radon).

Preventative Maintenance Note: Hairline cracks and spalling are common at the exterior foundation of the home. Cracks and spalling should beproperly assessed and sealed (e.g. parged, professionally sealed) to help reduce the risk of further deterioration (e.g. water intrusion in the fall andwinter season with the risk of freezing and expanding). Monitor the foundation regularly (e.g. spring) and evaluate/repair as required.

Items recommended for repair or replacement should be further evaluated and repaired or replaced by qualified/certified and insuredcontractors/technicians (e.g. foundation contractor).

Styles & Materials

Foundation:Masonry blockBrick

Exterior Foundation Limitations:Restricted observation due to sidingRestricted observation due to grading

Approximate % of Exerior FoundationVisible:1 - 5%

Interior Foundation Limitations:Restricted observation due to basementfinish

Approxmiate % of Interior FoundationVisible:1 - 5%

Method used to observe attic:Inaccessible

Attic Limitations:No Attic Access

% Attic Viewable:0%

IN NI NP RR

3.0 Foundations, Basement and Crawlspace - Exterior •

3.1 Foundations, Basement and Crawlspace - Interior •

3.2 Walls (Structural) •

3.3 Floors/Ceiling/Columns (Structural) •

3.4 Roof Structure and Attic •

IN NI NP RRIN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

I Inspect Three60

13 Trefann Street Page 9 of 32

Page 10: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Comments:

The structure of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas ofconcern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.

3.3 The floors have sloping common in a home of this age at the main, 2nd and 3rd floor.

3.3 Item 1(Picture) Kitchen Floor 3.3 Item 2(Picture) 3rd Floor - Top of Steps

I Inspect Three60

13 Trefann Street Page 10 of 32

Page 11: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

4. Insulation and VentilationThe home inspector shall observe: Insulation and vapor retarders in unfinished spaces; Ventilation of attics and foundation areas; Kitchen, bathroom,and laundry venting systems; and the operation of any readily accessible attic ventilation fan, and, when temperature permits, the operation of anyreadily accessible thermostatic control. The home inspector shall describe: Insulation in unfinished spaces; and Absence of insulation in unfinishedspace at conditioned surfaces. The home inspector shall: Move insulation where readily visible evidence indicates the need to do so; and Moveinsulation where chimneys penetrate roofs, where plumbing drain/waste pipes penetrate floors, adjacent to earth filled stoops or porches, and atexterior doors. The home inspector is not required to report on: Concealed insulation and vapor retarders; or Venting equipment that is integral withhousehold appliances.

Items recommended for repair or replacement should be further evaluated and repaired or replaced by qualified/certified and insuredcontractors/technicians.

Styles & Materials

Attic Insulation:UNKNOWN

Estimated Attic Insulation R-Value:UNKNOWN

Ventilation:Static VentsSoffit Vents

Exhaust Fans:Fan only

Dryer Power Source:Electric

Dryer Vent:Flexible FoilEnsure proper installation of an approvedventing product for safety (e.g. flexible/rigidaluminum)

Interior Wall Limitations:Restricted observation due to finish

IN NI NP RR

4.0 Insulation in Attic •

4.1 Insulation - Walls/Basement •

4.2 Vapor Retarders (in Crawlspace or basement) •

4.3 Ventilation of Attic and Foundation Areas •

4.4 Venting Systems (Kitchens, Baths and Laundry) •

4.5 Ventilation Fans and Thermostatic Controls in Attic •

4.6 Firewall(s) - Attic, Basement •

IN NI NP RRIN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

I Inspect Three60

13 Trefann Street Page 11 of 32

Page 12: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Comments:

The insulation and ventilation of the home was inspected and reported on with the above information. While the inspector makes every effort to findall areas of concern, some areas can go unnoticed. Venting of exhaust fans or clothes dryer cannot be fully inspected and bends or obstructions canoccur without being accessible or visible (behind wall and ceiling coverings). Only insulation that is visible was inspected. Please be aware that theinspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended thatqualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

4.4 (1) The dryer vent/lint catcher should be cleaned regularly of lint and debris. Vents should be installed short andstraight as possible to ensure proper function. Refer to dryer manufacturer specifications to ensure proper installationand for safety.

4.4 Item 1(Picture) Lint Catcher

4.4 (2) I recommend installing a proper dryer venting product (e.g. rigid/corrugated steel/aluminum).

4.4 Item 2(Picture) Dryer Vent 4.4 Item 3(Picture) Dryer Vent

I Inspect Three60

13 Trefann Street Page 12 of 32

Page 13: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

5. InteriorsThe home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number ofinstalled cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows andinterior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on buildingcomponents. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors;Carpeting; or Draperies, blinds, or other window treatments.

Preventative Maintenance Note: Ensure relative humidity levels are monitored and maintained on a regular basis. Relative humidity levels in thehome (e.g. main, second and basement levels) should be maintained (e.g. humidification or dehumidification) between 30 and 50%, to help ensure acomfortable living space, and to help reduce the risk of microbial activity.

Items recommended for repair or replacement should be further evaluated and repaired or replaced by qualified/certified and insuredcontractors/technicians.

IN NI NP RR

5.0 Ceilings •

5.1 Walls •

5.2 Floors • •

5.3 Steps, Stairways, Balconies and Railings •

5.4 Counters and Cabinets (representative number) •

5.5 Doors (representative number) •

5.6 Windows (representative number) •

5.7 Shower/Bath Enclosures/Jetted Tubs •

IN NI NP RRIN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

Comments:

5.0 The third floor has cathedral ceilings. The cathedral ceiling is like a "mini-attic", with all the systems that a fullattic has, but none of it is visible. Due to the inherent lack of access, the systems within a cathedral ceiling can not befully inspected.

5.0 Item 1(Picture) 3rd Floor Ceiling

I Inspect Three60

13 Trefann Street Page 13 of 32

Page 14: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas ofconcern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructedfrom view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

5.2 The transition is cracked or damaged at the 2nd floor bathroom/shower.

Potential Risk: Appears to be cosmetic.

5.2 Item 1(Picture) Marble Transition For Shower

I Inspect Three60

13 Trefann Street Page 14 of 32

Page 15: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

6. Electrical System

I Inspect Three60

13 Trefann Street Page 15 of 32

Page 16: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main over current device, and main anddistribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their over current devices, and the compatibility of theirampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located insidethe house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, andall receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smokedetectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead orunderground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The homeinspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of acentral system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over currentdevice except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliarydistribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security,cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment.

Note: GFCI (Ground Fault Circuit Interrupter) outlets help reduce the risk of electrical shock. GFCI's detect a change in current between the "hot" and"neutral" wires and "trip" the circuit, shutting off power to the circuit.

Please note, depending on the location or type of installation of pot-lights (e.g. attic space with insulation covering pot-lights), pot-lightshave to be certified to meet these conditions. Typically a standard home inspection cannot verify the product due to finish or insulationcoverage. In these instances, further evaluation by a licensed electrical contractor is recommended.

Please ensure when installing light bulbs (or for existing light bulbs), the light bulbs meet the rating specified by the manufacturer of thelight fixture.

Ensure all panels and sub-panels are properly labelled to help ensure safety/proper use. Ensure all outlets and switches have a properplate cover installed to help ensure safety.

Carbon Monoxide:

- Have a qualified technician install and regularly inspect all fuel burning appliances.

- Regularly inspect fireplaces and chimneys to insure proper ventilation.

- Never use a gas or charcoal barbecue indoors.

- Never start a car or gas powered machinery in a closed garage.

- Install carbon monoxide detectors in your home (install carbon monoxide detectors on each level of a house where sleeping occurs, and in as manylocations as necessary to insure the carbon monoxide alarm is audible in every bedroom when the doors are closed.

- Check with your local town office and manufacturer specifications for installation/location rules.

Ontario Fire Code: "When are CO alarms required to be installed within a house?"

If the house contains a fuel burning appliance, fireplace or an attached garage, a CO alarm is required to be installed adjacent to each sleeping areain the house.

For optimum protection, it is recommended that additional CO alarm(s) be installed in other levels and/or areas of the home that are in proximity to aCO source, subject to the distance limits provided in the product’s instruction manual.

[Div. B, 2.16.2.1.]

Ontario Fire Code: "What does “adjacent to each sleeping area” mean in terms of installation location?"

In general, this phrase means the hallway serving or area outside the sleeping area. For instance, a CO alarm must be installed in the hallwayadjacent to multiple bedrooms in a house or apartment.

However, there may be situations where “adjacent to each sleeping area” refers to the area around the bed, within the bedroom or sleeping areaitself.

[Div. B, 2.16.2.1.]

Smoke Detectors:

- Insure smoke detectors are installed per local policies, and based on manufacturer specifications (e.g. replace detectors older than 8 years).

- Test all smoke detectors upon moving in and monthly thereafter.

- The Ontario Fire Code requires all homes to have properly maintained and operating smoke alarms on every level and outside all sleepingareas.

- For maximum protection, install one in every room. To help ensure safety, ensure smoke detectors are "hard wired" with a batterybackup.

- Consult with your local fire department for additional safety recommendations including fire safety, fire escape plans/egress, etc.

I Inspect Three60

13 Trefann Street Page 16 of 32

Page 17: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Electrical System Maintenance:

- An example of warning signs that tell you there may be a problem with the wiring includes: flickering lights; breakers that always trip; fuses thatalways blow; a burning smell coming from appliances or in rooms, and discoloured wall outlets.

- Electrical currents generate waste heat. Over time that heat can cause the conductor to expand and contract. Eventually it will loosen theconnection, which can cause an "arc". This creates a risk of an electrical fire.

- Counterfeit electrical products can also cause electrical fires. In many cases, the only way to know that they are counterfeit is to send them to a lab.

- Overloaded circuits are also at risk.

- When purchasing a home (e.g. older than 15 years old), source a licensed electrical contractor to check out the electrical system to ensure thesystem is up to code and all connections are "tight".

- It is recommended to have the electrical system in your home evaluated by a licensed electrical contractor every 4 years. Be safe!

Electrical installations in the Attic are not accessible due to insulation cover.

Please note, electrical defects are considered a safety hazard until repaired. Items recommended for repair should be further evaluatedand repaired or replaced by qualified, licensed and insured electrical contractors.

Styles & Materials

Electrical Service Conductors:Below ground

Panel Capacity:100 AMP

Panel Type:Circuit breakers

Main Panel Location:Basement

Electric Panel Manufacturer:COMMANDER

Branch wire 15 and 20 AMP:Copper

Wiring Methods:Romex

IN NI NP RR

6.0 Service Entrance Conductors •

6.1 Location of Main and Distribution Panels •

6.2 Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels •

6.3 Gas Line Grounded •

6.4 Branch Circuit Conductors, Overcurrent Devices •

6.5Connected Devices and Fixtures (Observed from a representative number operation of ceiling fans,lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling'sexterior walls)

6.6 AC Breaker Size •

6.7 Operation of GFCI (Ground Fault Circuit Interrupters) •

6.8 Smoke/Heat Detectors/Carbon Monoxide Detectors •

6.9 Carbon Monoxide Detectors •

IN NI NP RRIN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

I Inspect Three60

13 Trefann Street Page 17 of 32

Page 18: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Comments:

6.1 Electrical Panel

6.1 Item 1(Picture) Electrical Panel 6.1 Item 2(Picture) Panel Covers Removed

6.1 Item 3(Picture) Main Shut Off - 100 Amps

I Inspect Three60

13 Trefann Street Page 18 of 32

Page 19: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

6.2 (1) Note, the main panel is mounted sideways. Ensure you review and understand the proper use and functionof the breaker on and off positions.

6.2 Item 1(Picture)

6.2 (2) The main panel has at least 1 double tap.

6.2 Item 2(Picture) Double Tap At Breaker

I Inspect Three60

13 Trefann Street Page 19 of 32

Page 20: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

6.2 (3) The main panel at least 8 breakers that are different from the panel manufacturer.

6.2 Item 3(Picture) 6.2 Item 4(Picture)

6.7 (1) Two GFCI (Ground Fault Circuit Interrupter) outlets at the 3rd floor did not trip when tested.

6.7 Item 1(Picture) 3rd Floor - North Side

6.7 Item 2(Picture) 3rd Floor South Side

I Inspect Three60

13 Trefann Street Page 20 of 32

Page 21: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

The electrical system of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areasof concern, some areas can go unnoticed. Outlets were not removed and the inspection was only visual. Any outlet not accessible (behind therefrigerator for example) was not inspected or accessible. Please be aware that the inspector has your best interest in mind. Any repair itemsmentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection orrepair issues as it relates to the comments in this inspection report.

6.7 (2) The GFCI (Ground Fault Circuit Interrupter) outlet(s) at the 2nd floor is wired incorrectly (reverse polarity).

6.7 Item 3(Picture)

I Inspect Three60

13 Trefann Street Page 21 of 32

Page 22: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

7. Plumbing SystemThe home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures andfaucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; pipingsupports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls;automatic safety controls; and chimneys, flues, and vents; and Sump pumps. The home inspector shall describe: Water supply and distribution pipingmaterials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspectorshall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet isconnected to an appliance. The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supplyand waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixturefaucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-sitewaste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar waterheating equipment; or Observe the system for proper sizing, design, or use of proper materials.

Preventative Maintenance Note - Supply Hoses: It is recommended to replace rubber, plastic and vinyl supply hoses with an alternate product(e.g. braided steel hoses) to help reduce the risk of leaking. For example, washer rubber supply hoses should not pressurized when not in use, andreplaced every 5 years. Plastic and vinyl hoses are sometimes used to supply water to sinks, humidifiers and refrigerators. Consult a qualifiedplumber.

Preventative Maintenance Note - Shower and Sink Fixtures: It is recommended to ensure shower and sink fixtures are properly sealed to helpreduce the risk of water intrusion and microbial activity. Monitor caulking and seals regularly.

Preventative Maintenance Note - PEX Plumbing: Some Pex products have been know to have issues, including corrosion/leaking at fittings (e.g.Kitec, Zurn). It is recommended to have the Pex system monitored regularly by a qualified plumber.

Limited Scope Note: Shut-off valves including the main water meter shut-off, water supply shut-offs (e.g. supply shut-offs to the exterior faucets,sink faucets and toilets), main gas meter shut-off and gas supply shut-offs, are not tested during the inspection due to possibility of leaking anddamage as a result of testing these items. It is recommended to have these systems tested with the Seller prior to "closing" or "taking possession ofthe property".

Potential Risk Note: Shower faucets with a hose attachment that can sit in standing water (e.g. tub or shower base) can contribute to contaminationto the public supply system, if there is a reverse pressure. It is recommended that these be removed or properly installed.

Potential Risk Note: Gas lines and connections can leak at any time (e.g. loose gas line, poor fitting, movement). It is recommended to have thegas lines and gas burning appliances assessed and serviced on a regular basis, by qualified, licensed and insured technicians (e.g. gas technician,HVAC technician).

Items recommended for repair or replacement should be further evaluated and repaired or replaced by qualified, licensed and insuredplumbers/technicians.

Styles & Materials

Water Source:Public

Main Water Shut-Off Location:Basement

Plumbing Water Supply (into home):Copper

Plumbing Water Distribution (insidehome):PEX

PEX Type/Manufacturer (waterdistribution inside home):Pure Link Plus PEX

Plumbing Waste/Vents:ABS

Plumbing Limitations:Limited observation due to finish

Access to Drain/Clean-outs and Shut-Offs:Limited observation due to basement finish

Sewers:Public

Gas Meter Location:Exterior

Interior Gas Line (Furnace Room/Furnace) - Gas Leak Test:Ok

Water Heater Power Source:Natural Gas

Water Heater Manufacturer:GSW

Water Heater Type:Tank

Water Heater Location:BasementFurnace Room

Water Heater Estimated Age:3 - 4 Years

Water Heater Estimated Design Life:10 Years

Water Heater Near or At Its' DesignLife?:No

I Inspect Three60

13 Trefann Street Page 22 of 32

Page 23: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Sump/Ejector Pump Restrictions:Cover(s) Sealed

IN NI NP RR

7.0 Plumbing Drain/Vent and Waste Systems •

7.1 Plumbing Water Supply, Distribution System and Fixtures • •

7.2 Location of Plumbing Drains, Drain Clean-outs and Shut-off Valves •

7.3 Hot Water Systems and Associated Controls, Flues and Vents •

7.4 Main Water Meter (Shut-Off Not Tested) •

7.5 Main Fuel Meter (Shut-Off Not Tested) •

7.6 Gas Lines •

7.7 Sump Pump/Ejector Pump •

7.8 Plumbing Fixtures •

IN NI NP RRIN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

Comments:

7.1 It is recommended to replace rubber, plastic and vinyl supply hoses with an alternate product (e.g. braided steelhoses) to help reduce the risk of leaking. For example, washer rubber supply hoses should not pressurized when notin use, and replaced every 5 years. Plastic and vinyl hoses are sometimes used to supply water to sinks, humidifiersand refrigerators.

7.1 Item 1(Picture)

I Inspect Three60

13 Trefann Street Page 23 of 32

Page 24: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

The plumbing in the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas ofconcern, some areas can go unnoticed. Washing machine drain line for example cannot be checked for leaks or the ability to handle the volumeduring drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed and barely working during an inspection butthen fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waiting for closing) rust or deposits within thepipes can further clog the piping system. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.

7.3 Hot Water Tank

7.3 Item 1(Picture) Hot Water Tank

7.3 Item 2(Picture) Data Plate

7.4 Water Meter/Shut Off

7.4 Item 1(Picture) Water Meter 7.4 Item 2(Picture) Shut Off

I Inspect Three60

13 Trefann Street Page 24 of 32

Page 25: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

8. Heating / Central Air ConditioningThe home inspector shall observe permanently installed heating and cooling systems including: heating equipment and cooling equipment that iscentral to home; normal operating controls; exterior chimneys and vents where readily visible; heat distribution systems including fans, pumps, ductsand piping, air filters, registers, and radiators; and the presence of an installed heat source in each room. The home inspector shall describe: energysource; and heating equipment and distribution type. The home inspector shall operate the systems using normal operating controls. The homeinspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The homeinspector is not required to: operate heating systems when weather conditions or other circumstances may cause equipment damage; operateautomatic safety controls; ignite or extinguish solid fuel fires; or observe: the interior of flues; fireplace insert flue connections; humidifiers; electronicair filters; or the uniformity or adequacy of heat supply to the various rooms. Electric baseboard heaters and electric fireplaces are out of scope ofthis inspection.

Please note, Heat Exchangers cannot be inspected with a standard inspection. Heat Exchangers, Heat Exchanger Covers and heatingsystem parts can fail at any time. Servicing/maintenance is recommended by a licensed HVAC technician prior to closing.

It is recommended to obtain the service history from the seller to ensure the systems have been properly maintained.

Items recommended for repair or replacement should be further evaluated and repaired or replaced by licensed and insured technicians(e.g. HVAC technician, Gas technician).

Styles & Materials

Heat System Brand:KEEPRITE

Heat Type:Forced Air

Energy Source:Natural gas

Estimated Heating System Age:2 - 3 Years

Heating System Design Life:15 - 20 Years

Heating System Nearing Its Design Life:No

Number of Heat Systems (excludingwood):One

Cooling Equipment Type:Air conditioner unit

Cooling Equipment Energy Source:Electricity

AC Size:2.5 Ton

Central Air Manufacturer:KEEPRITE

Estimated Cooling Equipment Age:2 - 3 Years

Cooling Equipment Estimated DesignLife:15 - 20 Years

Cooling System Nearing Its' DesignLife?:No

Number of Cooling Systems:One

IN NI NP RR

8.0 Heating Equipment •

8.1 Normal Operating Controls •

8.2 Distribution Systems (including fans, pumps, ducts and piping, insulation, air filters, registers, radiators) •

8.3 Presence of Installed Heat Source in Each Room •

8.4 Vents/In-Takes •

8.5 Heat Recovery Ventilator/Air Cleaner •

8.6 Solid Fuel Heating Devices (Fireplaces, Woodstove, Chimney, Vents) •

8.7 Gas/LP Firelogs and Gas Fireplaces, and vents •

8.8 Cooling and Air Handler Equipment •

8.9 Normal Operating Controls •

8.10 Presence of Installed Cooling Source in Each Room •

IN NI NP RRIN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

I Inspect Three60

13 Trefann Street Page 25 of 32

Page 26: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

I Inspect Three60

13 Trefann Street Page 26 of 32

Page 27: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

Comments:

I Inspect Three60

13 Trefann Street Page 27 of 32

Page 28: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

8.0 Heating System

Manufacturer: Keeprite

Model Number: N9MSB0801716B

Serial Number: A135147338

Date of Manufacture: December 2013

The heating function was not tested. The A/C function was tested.

I Inspect Three60

13 Trefann Street Page 28 of 32

Page 29: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

8.0 Item 1(Picture) Furnace Cabinet 8.0 Item 2(Picture) Cabinet DoorsRemoved

8.0 Item 3(Picture) Data Plate

I Inspect Three60

13 Trefann Street Page 29 of 32

Page 30: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

The heating and cooling system of this home was inspected and reported on with the above information. While the inspector makes every effort tofind all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involveremoval and inspection behind service door or dismantling that would otherwise reveal something only a licensed heat contractor would discover.Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. Itis recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

8.8 Manufacturer: Keeprite

Model Number: N4A330AKC200

Serial Number: E134905075

Date of Manufacture: December 2013

8.8 Item 1(Picture) AC CondenserCabinet

8.8 Item 2(Picture) Data Plate

I Inspect Three60

13 Trefann Street Page 30 of 32

Page 31: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

General Summary

I Inspect Three60

2343 Queen Street EastToronto, Ontario

M4E 1H2(416) 347-5187

Customer

Address13 Trefann Street

Toronto ONT M5A 3A9

The following items or discoveries indicate that these systems or components do not function as intended or adverselyaffects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequentobservation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it inproper functioning condition or recommendations to upgrade or enhance the function or efficiency of the home. ThisSummary is not the entire report. The complete report may include additional information of concern to the customer. It isrecommended that the customer read the complete report.

1. Roofing

1.1 FlashingsInspected, Repair or ReplacePreventative Maintenance Note:

There is an exposed area at the north side. Adding a flashing or sealing this area can prevent further deterioration/water intrusion.

Potential Risk: Water intrusion.

4. Insulation and Ventilation

4.4 Venting Systems (Kitchens, Baths and Laundry)Repair or Replace(1) The dryer vent/lint catcher should be cleaned regularly of lint and debris. Vents should be installed short andstraight as possible to ensure proper function. Refer to dryer manufacturer specifications to ensure properinstallation and for safety.(2) I recommend installing a proper dryer venting product (e.g. rigid/corrugated steel/aluminum).

I Inspect Three60

13 Trefann Street Page 31 of 32

Page 32: 13 Trefann Street / I Inspect Three60 / Frank Bernardo€¦ · Toronto ONT M5A 3A9 I Inspect Three60 Frank Bernardo 2343 Queen Street East Toronto, Ontario M4E 1H2 (416) 347-5187

5. Interiors

5.2 FloorsInspected, Repair or ReplaceThe transition is cracked or damaged at the 2nd floor bathroom/shower.

Potential Risk: Appears to be cosmetic.

6. Electrical System

6.2 Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution PanelsRepair or Replace(1) Note, the main panel is mounted sideways. Ensure you review and understand the proper use and function ofthe breaker on and off positions.(2) The main panel has at least 1 double tap.(3) The main panel at least 8 breakers that are different from the panel manufacturer.

6.7 Operation of GFCI (Ground Fault Circuit Interrupters)Repair or Replace(1) Two GFCI (Ground Fault Circuit Interrupter) outlets at the 3rd floor did not trip when tested.(2) The GFCI (Ground Fault Circuit Interrupter) outlet(s) at the 2nd floor is wired incorrectly (reverse polarity).

7. Plumbing System

7.1 Plumbing Water Supply, Distribution System and FixturesInspected, Repair or ReplaceIt is recommended to replace rubber, plastic and vinyl supply hoses with an alternate product (e.g. braided steelhoses) to help reduce the risk of leaking. For example, washer rubber supply hoses should not pressurized whennot in use, and replaced every 5 years. Plastic and vinyl hoses are sometimes used to supply water to sinks,humidifiers and refrigerators.

Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of theneed for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use;Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value ofthe property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system thatwas not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmeticitems, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties orguarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area orperform any procedure that may damage the property or its components or be dangerous to the home inspector or otherpersons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or componentthat does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment,plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspectedadverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise,contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control orremove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Sincethis report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensedinspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.