Page 1: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 1/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

Programming User Guide for HAL2 HAL2: ARGOS beacon

Page 2: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 2/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

Table Of Contents

1. Introduction ......................................................................................................................................... 3 2. Precaution of Use ............................................................................................................................... 3 3. RF Interfaces ...................................................................................................................................... 5 4. RS-232 and Supply Cable for HAL2 ................................................................................................... 6 5. HyperTerminal Serial Interface Set-Up............................................................................................... 8 6. Preparation ......................................................................................................................................... 8 7. Procedure For Programming the Beacon ........................................................................................... 9 8. Transmission Set-Up : (Parametres Emission)................................................................................. 10 9. Sequence of Emission Set-Up.......................................................................................................... 14 10. Beacon Monitoring Example............................................................................................................. 17 11. Record of revisions ........................................................................................................................... 18 12. Approval............................................................................................................................................ 19

Page 3: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 3/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

1. Introduction

We thank you for the purchase of HAL-2 beacon which, we hope, will give you satisfaction in all your applications.

Before going into the programming of the beacon it is mandatory to know two French words :

- “OUI” for “Yes” - “NON” for “No”.

Now that you are French fluent, you can start programming the ARGOS beacon.

2. Precaution of Use

Before programming the beacon be sure that:

- You have the right RS232 cable (see §5) - Your ID Address is in HEXADECIMAL - You have a recent version of HyperTerminal. If not, we invite you to download one at the

following address: http://www.hilgraeve.com/htpe/download.html - The HyperTerminal serial interface is correctly set-up (See §6)

Page 4: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 4/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

3. Glossary

FRENCH ENGLISH

DEFAUT DEFAULT

FERMER CLOSE

FREQUENCE FREQUENCY

HAL2 ARGOS / SCD Beacon

ID Address of The Beacon

LECTURE EN COURS READING IN PROCESS

POWER OUTPUT POWER

PROGRAMMATION EN COURS PROGRAMMING IN PROCESS

SEULEMENT MOI MYSELF ONLY

SUIVANT NEXT

TAILLE ID ID Size

TOUT LE MONDE EVERYBODY

TR REPETITION TIME FOR EMISSION

Page 5: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 5/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

4. RF Interfaces

The GPS input and the 401 RF output are made with micro RF connectors (Female MCX 50 Ohms Connectors).

- The RF output connector for the ARGOS / SCD antenna is located at the opposite side of connectors.

Page 6: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 6/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

12345123456789101112

connect 5 Pconnect 12 P

5. RS-232 and Supply Cable for HAL2

HAL2 : two miniature connectors.

Power Connector The 5-pin connector allows for power supply and ON/OFF command of the beacon.

Pin 1 +VCC positive power supply (from 6.5 to 14V) Pin 2 +VCC positive power supply (from 6.5 to 14V) Pin 3 OFF HAL HAL ON/OFF command Pin 4 GND 0Volt negative power supply return line Pin 5 GND 0Volt negative power supply return line

The beacon's 5-pin connector is a MOLEX ref. 53048-0510 ; the mating female jack is ref. 51021-0500 fitted with 50079-8 contacts

The HAL2 shall be powered from a voltage ranging from 7 to 14V, the power source shall be capable of supplying a maximum current of 1 Ampere, shall feature a minimum internal impedance (< 0.3 Ohms), and shall not generate disturbing frequencies.

If the distance exceeds 50 cm, then wire section shall be greater than 0.6 mm

mm².

Warning

Pins 1 & 2 shall be connected together to the positive terminal of the power supply.

Pins 4 & 5 shall be connected together to the negative terminal of the power supply.

Caution : The electrical 0 Volt (pins 4 & 5) is linked to the mechanical ground of the case.

Pin 3 OFF HAL shall be either left unconnected (HAL ON) or connected to 0 Volt (HAL OFF).

The standard interface operates by means of an open collector transistor. Pin 3 is fed to the positive polarity of the supply by means of a 1 MOhm internal resistor.

Aninha
Highlight
Page 7: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 7/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

Input-Output Connector The 12-pin connector allows the RS 232 dialogue and connection of the various inputs / outputs.

Pin 1 TXD serial link output Pin 2 RXD serial link input Pin 3 GND 0 volt Pin 4 FLAG_TX transmission signal Pin 5 TOR 1 digital logic input Pin 6 TOR 2 digital logic input Pin 7 Counting input. Pin 8 GND 0 volt Pin 9 AN1 analogue input 1 Pin 10 AN2 analogue input 2 Pin 11 AN3 analogue input 3 Pin 12 AN4 analogue input 4

The beacon's 12-pin connector is a MOLEX ref. 53048-1210 ; its mating part is a female jack ref. 51021-1200 fitted with 50079-8 contacts.)

TXD serial link output is to be connected to RXD of the external interface (PC for example).

RXD serial link input is to be connected to TXD of the external interface (PC for example).

Warning

To avoid any hazardous change of mode when using the beacon, it is imperative to connect:

- PIN N° 4 of the J1 connector to PIN N°8 of the J2 connector - PIN N° 5 of the J1 connector to PIN N° 6 of the J2 connector.

Page 8: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 8/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

6. HyperTerminal Serial Interface Set-Up

The HyperTerminal serial interface must be configured as follows:

- Data Rate : 9600 - Data Length : 8 Bits - Stop Bit : 1 - Start Bit: 1 - Parity : No Parity - Flow Control : No

7. Preparation

1. Connect the VHAL-2 serial interface to the PC 2. Launch your HyperTerminal set as mention here above (see §6): 3. Switch On the Beacon

The following menu should appear:

RUN

Software:0.12 [06000016]

Page 9: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 9/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

8. Procedure For Programming the Beacon

Then press successively the following keys (it is a password) :

"Space Bar"

[ ] : Home

[s]

[1]

[2]

[3]

[4]

And the following menu should appear:

-----------------------------------------------------------

MODE REGLAGE USINE

Software:4.03 [00060359]

A REGLAGE DE LA FREQUENCE

B REGLAGE DE LA PUISSANCE RF

C REGLAGE DE LA MODULATION

D DEBUG CARTE

E TCXO

F PARAMETRES EMISSIONS

G SEQUENCE EMISSIONS

H DOWNLOAD

I UPLOAD

J AUTORISER BOOTLOADER

K RAFRAICHIR INFO

L NUMERO DE SERIE

- Tapez [X] pour sortir

To reach the various possibilities of use of the beacon, you only have to set-up : the Transmission parameters (key [G ]) and the Mode parameters (key [H]).

Warning To avoid a return to our plant and a repair for which you will be charged, we advise you against accessing to the other menus without having been authorized or guided by ELTA.

Page 10: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 10/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

9. Transmission Set-Up : (Parametres Emission)

This menu enables to define all the parameters for one transmission. And up to 8 different transmissions can be set-up.

Press Key [F] PARAMETRES EMISSIONS. Then the following screen should be displayed.

-----------------------------------------------------------

MODE REGLAGE USINE

Software:4.03 [00060359]

A) EMIS. COURANTE : 1

B) TR FIXE : 0

C) ADRESSE 28 : 0

D) MESSAGE INTERNE: 0

E) HEADER PRESENT : 0

F) NBR OCTETS EXT : 32

G) ID : 00010810

H) FREQUENCE : 401650000

I) PUISSANCE : 1W

J) HEADER : 25

K) RESOL PUISSANCE: 8

L) RESOL ALIM : 8

M) RESOL TEMP. : 8

N) RESOL COMPTEUR : 0

O) TOR1 : 0

P) TOR2 : 0

Q) RESOL AN1 : 0

R) RESOL AN2 : 0

S) RESOL AN3 : 0

T) RESOL AN4 : 0

U) MSG: 0102030405060708091011121314151617181920212223242526272829303132

V) MEMORISE

- Tapez [X] pour revenir au menu -

Page 11: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 11/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

A. Press Key [A] . A) EMIS. COURANTE : 1 Select 1 for setting-up the first transmission (Up to 8 different transmissions can be set-up). press [←] or [→] to change the value (1 to 8). Press Key [V] to valid the Set-Up. Remark : All the parameters described below characterize the selected transmission.

B. Press Key [B] .

B) TR FIXE : O

This parameter must be set to “O“ press [←] or [→] to change the value. Press Key [V] to valid the Set-Up

C. Press Key [C] .

C) ADRESSE 28 : 0

Your Hexadecimal ID can be 20 bits or 28 Bits. If your ID is 28 bits you must select “1”. If your ID is 20 bits, you must select “0”. press [←] or [→] to change the value. Press Key [V] to valid the Set-Up Remark : when you address is 20 bits the ARGOS frame has a maximum length of 32 bytes when you address is 28 bits the ARGOS frame has a maximum length of 31 bytes

D. Press Key [D] .

D) MESSAGE INTERNE: 0 Set this value to “1” if you want that your ARGOS frame contains INTERNAL MESSAGE of the beacon. Set this value to “0” if you want that your ARGOS frame contains EXTERNAL MESSAGES. press [←] or [→] to change the value. Press Key [V] to valid the Set-Up

E. Press Key [E] .

E) HEADER PRESENT: “0”

Set this value to “0” if you don’t want to add a header to your INTERNAL MESSAGE. Set this value to 4 or 8 (bits) according to the desired header length press [←] or [→] to change the value (4 or 8). Press Key [V] to valid the Set-Up

Page 12: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 12/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

F. Press Key [F] .

F) NBR OCTETS EXT : 32

Adjust the value of your EXTERNAL MESSAGE to the correct length (the selected Bytes value has to be a multiple of 4 and 32 Bytes is the maximum).

press [←] or [→] to change the value. Press Key [V] to valid the Set-Up Remark : To enable the sending of external message be sure that for MESSAGE INTERNE, “0” is selected (see § D)

G. Press Key [G] .

G) ID : 000 FFFFF

press [enter] for being able to type the Hex address Type your Hex Address “00FFFFF” then press [enter] (the field is formatted automatically). Press Key [V] to valid the Set-Up Remark: Be sure that your ID Address is in HEXADECIMAL and that you have selected the right ID address length (see § C)

I. Press Key [I] .

I) PUISSANCE : 1W

Select the desired emitted OUTPUT POWER value :1

- 2 W - 1 W - 500 mW - 100 mW (only for lab tests)

press [←] or [→] to change the value. Press Key [V] to valid the Set-Up

Press [X] to go back to the main menu.

Page 13: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 13/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

Then the following screen should be displayed

-----------------------------------------------------------

MODE REGLAGE USINE

Software:4.03 [00060359]

A REGLAGE DE LA FREQUENCE

B REGLAGE DE LA PUISSANCE RF

C REGLAGE DE LA MODULATION

D DEBUG CARTE

E TCXO

F PARAMETRES EMISSIONS

G SEQUENCE EMISSIONS

H DOWNLOAD

I UPLOAD

J AUTORISER BOOTLOADER

K RAFRAICHIR INFO

L NUMERO DE SERIE

- Tapez [X] pour sortir -

Press Key [G]

Page 14: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 14/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

10. Sequence of Emission Set-Up

The aim of the next programming sequence is to enable 1 transmission once every 200 seconds

Then the following screen should be displayed

A) DEPART : 0j

B) DUREE ON : 0h

C) DUREE OFF: 0h

D) SEQUENCE : 1/24

E) EMISSION : 1

F) DELAIS : 200s

- Tapez [X] pour revenir au menu -

H. Press Key [A] .

A) DEPART : 0j

To start transmission without delay you must select “0” press [←] or [→] to change the value.

I. Press Key [B] .

B) DUREE ON : 0h

Regarding you are not cycling you must select “0” press [←] or [→] to change the value.

J. Press Key [C] .

C) DUREE OFF: 0h

Regarding you are not cycling you must select “0” press [←] or [→] to change the value.

K. Press Key [D] .

D) SEQUENCE : 1/24

This function enables the scheduling of the transmission. In your case you have a single ARGOS emission for this reason you have to select “1”/24 press [←] or [→] to change the value.

Page 15: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 15/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

L. Press Key [E] .

E) EMISSION : 1

It is possible to transmit up to 3 different emissions (messages) with the HAL-2. Regarding that just one is required for your application you must select “1” press [←] or [→] to change the value.

M. Press Key [F] .

F) DELAIS : 200s

You want a delay of 200 seconds between emissions. you must select “200” press [←] or [→] until you reach the expected value.

To be sure you will loop on this “SEQUENCE” you must check that there is no other active “SEQUENCE” . To process this checking please: Press Key [D] .

press [←] or [→] until you obtain 2/24 Then the following screen should be displayed

A) DEPART : 0j B) DUREE ON : 0h C) DUREE OFF: 0h D) SEQUENCE : 2/24 E) EMISSION : 0 F) DELAIS : 0s - Tapez [X] pour revenir au menu -

If not, change value as mentioned hereafter : A) DEPART : 0j

To start transmit without delay you must select “0” press [←] or [→] to change the value.

N. Press Key [B] .

B) DUREE ON : 0h

Regarding you are not cycling you must select “0” press [←] or [→] to change the value.

Page 16: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 16/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

O. Press Key [C] .

C) DUREE OFF: 0h

Regarding you are not cycling you must select “0” press [←] or [→] to change the value.

P. Press Key [E] .

E) EMISSION : 0

you must select “0” press [←] or [→] to change the value.

Q. Press Key [F] .

F) DELAIS : 0s

“0” press [←] or [→] until you reach the expected value.

R. Press [X] to exit.

S. Press [X] to exit . When everything is done we advise you to do a general checking as usual

Page 17: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 17/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

11. Beacon Monitoring Example

You will find hereafter a example of HAL-2 monitoring message displayed through HyperTerminal.

Message displayed after programming the beacon as follows:

- ID = 20 Bits - Address = FFFF Hexadecimal - Message Length = 32 Bytes - 1 message once every 200 Seconds

S01,M01,TB8,5528,822,27,FFFE2FF0FFFF0102030405060708091011121314151617181920212223242526272829303132

Software:4.03 [00060359]

S01,

Sequence 1

M01, Message 1

TB8, Remaining time before next transmission

5528, Internal Temperature

822, Voltage

27, Power

FFFE2F Synch Format

F Message Length

0FFFF Hexadecimal Address

0102030405060708091011121314151617181920212223242526272829303132 Transmitted External Message

Page 18: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 18/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

12. Record of revisions

Issue Author Update comments Date

A CBC Reference Document 17/10/11

Page 19: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 19/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

13. Approval

Written by :

Position Name Signature

Space Sales Mngr Christophe CHATAIN

Checked by :

Position Name Signature

Approved by :

Position Name Signature

Page 20: 11E66919 a HAL2 User Guide

ELTA

HAL2: ARGOS beacon - 11E60337 - A October 17th, 2011 Page : 20/20

Programming User Guide for HAL2 CONFIDENTIAL INDUSTRY Form : 99Q80269 Rev. : H

This document is the property of ELTA and shall not be reproduced or communicated without its authorization. © Copyright ELTA – 14 Place Marcel Dassault - BP 70048 – 31702 BLAGNAC Cedex – France – http://www.elta.fr

ELTA Head Office : 14 Place Marcel Dassault – BP 70048