104980410 control-valve-calibration-procedure-fisher-hc6010

Download 104980410 control-valve-calibration-procedure-fisher-hc6010

Post on 18-Jul-2015

253 views

Category:

Data & Analytics

3 download

Embed Size (px)

TRANSCRIPT

<ul><li><p>Qurayyah CCPP ProjectQurayyah CCPP Project Fail Free Commissioning</p><p>Control Valve(Fisher HC6010) </p><p>EPC) Commissioning Management Team</p></li><li><p> Page index</p><p>1. POSITIONER SPECIFICATION </p><p>2. POSITIONER AND ACTUATOR AIR FLOW2. POSITIONER AND ACTUATOR AIR FLOW</p><p>3. POSITIONER ATTACHMENT</p><p>4 SIGNAL LINE CONNECTION4. SIGNAL LINE CONNECTION</p><p>5. CALIBRATION PROCEDURE</p><p>6. MANUAL OPERATION </p><p>7.CONTROL VALVE LIMIT SWITCHES</p><p>8.ALARM AND STATUS</p><p>1</p></li><li><p>1. Positioner Specification </p><p>ElectricalSpecification</p><p>l dPowerSupply 1130Vdc</p><p>Communication Hartprotocol</p><p>MinimumOperatingCurrent 3.5mAwithoutmicroprocessor</p><p>MaximumVoltage 30Vdc</p><p>AnalogInputSignal 4 20mA</p><p>PositionerSpecification</p><p>Linearity 0.5%ofoutputspanAirConsumption 1.4bar(20psi)</p><p>MaximumAirSupply 10 bar(145psi)</p><p>2</p></li><li><p>2. Positioner And Actuator Air Flow (1/2)</p><p> Flow diagram on how the actuator moves closing and opening position in digital g g p g p gand analog mode.</p><p>3</p></li><li><p>2. Positioner And Actuator Air Flow (2/2)</p><p>positioner</p><p>actuator</p><p>positioner</p><p>4</p></li><li><p>3. Positioner Attachment (1/2 )Fieldvue DVC6010 Digital Valve Controller Mounted on Sliding-Stem Actuators with up to 2 inches Travel</p><p>5</p></li><li><p>3. Positioner Attachment (2/2)</p><p> Air to Open Actuator1. Insert the alignment pin in the hole marked A2. The feedback arm rotates counterclockwise, from A to B as air pressure to</p><p>the casing or lower cylinder increases.g y</p><p> Air to Close Actuator1. Insert the alignment pin in the hole marked B2. The feedback arm rotates clockwise from B to A as air pressure to the</p><p>casing or upper cylinder increases</p><p>6</p><p>casing or upper cylinder increases. </p></li><li><p>4. Signal Line Connection</p><p>7</p></li><li><p>5. Calibration Procedure (1/3)</p><p>. Connect 4 20mA source to the instrument Connect Hart Communicator and power ON</p><p>Auto Calibration Select to Auto travel calibration, the controlvalve start to stroke from 0% to 100% openautomatically.</p><p> Wait until the calibration is completed Wait until the calibration is completed.</p><p>Manual Calibration Select To Manual calibration, its allows you to determine 0% to 100% calibration point.</p><p>4 20mASource</p><p> Refer to Hart Communicator for some adjustment for tuning and travel calibration.</p><p>Hart Communicator</p><p>8</p></li><li><p>5. Calibration Procedure (2/3)H t C i t M THart Communicator Menu Tree</p><p>9</p></li><li><p>5. Calibration Procedure (3/3)H t C i t M THart Communicator Menu Tree</p><p>10</p></li><li><p>6. Manual Operation</p><p> Handwheel</p><p> Handwheel lock</p><p> Position travel indicator </p><p> Rotate the handwheel lock Anti-clockwise to operatethe handwheelthe handwheel</p><p>Start to rotate the handwheel lock to desire direction Clockwise for closing Anti clockwise for opening</p><p> If the handwheel reach the maximum turn, you can h k th iti i t l i di t if it i f ll lcheck the position in travel indicator if it is fully close</p><p>or fully open.</p><p>11</p></li><li><p>7. Control Valve Limit Switch</p><p> Limit switch for open position when controlvalve is in fully open the contact is close forvalve is in fully open, the contact is close forfully open feedback.</p><p> Limit switch for close position when controlvalve is in fully close the contact is open forvalve is in fully close, the contact is open forfully close feedback.</p><p>12</p></li><li><p>8.Alarm And Status</p><p>1</p><p>21 -2 -3 </p><p>1</p><p>3</p><p>44</p><p>5</p><p>6</p><p>13</p></li></ul>

Recommended

View more >