Air Cooled Closed Type Water Cooling System Adiabatic Cooling An air-cooling system that uses the cooling fan to cool the air. When external temperature exceeds 30°C, the cooling fan will operate at full speed to atomize the external water into the adiabatic chamber. Hence, water will not be in direct contact with the heat exchanger. DC Brushless Motor The DC Brushless Motor drives the die-cast aluminium axial fans. This saves mores than 30% of energy consumed as compared to the regular system. The aluminium made fans are more durable and does not require maintenance. In addition, noise level during operation is being controlled under 57db. Remote Control Panel Uses the latest Micro Processor. Constant supervision of the operating condition is made possible with the backlight function. Upon occurrence of error, the cause and solution will be displayed as the warning signal. This allows a smooth resolution of problem. Sensors have been set to monitor the temperature and pressure, which are necessary for data collection. Thus, the management of the production line is also made possible. Self-draining Water in the system is being drained out automatically without using valves. This prevents freezing and cracking of pipes during resting periods of the factory when external temperature falls below 0°C. This system can be used even in lines that propylene glycol cannot be used. Unifying of Units Control panel, tank, valve and other units are being unified into this single unit. This saves space and allows speedy operation. High level of durability of the pump unit and cooling tank is made possible with stainless steel. 5500 5500 5500 Ecobrid

Upload: others

Post on 08-Oct-2019

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 102-103 ecobrid 2 - MATSUImatsui.net/jp/product/pdf/ecobrid_201506.pdf · Ecobrid H H H Ecodrygel (Cooling Tower) Cooling Water Tank Microgel (Cooling & Heating Unit) Pump Unit Filter

Air Cooled Closed Type Water Cooling System

Adiabatic CoolingAn air-cooling system that uses the cooling fan to cool the air. When external temperature exceeds 30°C, the cooling fan will operate at full speed to atomize the external water into the adiabatic chamber. Hence, water will not be in direct contact with the heat exchanger.

DC Brushless MotorThe DC Brushless Motor drives the die-cast aluminium axial fans. This saves mores than 30% of energy consumed as compared to the regular system. The aluminium made fans are more durable and does not require maintenance. In addition, noise level during operation is being controlled under 57db.

Remote Control PanelUses the latest Micro Processor. Constant supervision of the operating condition is made possible with the backlight function. Upon occurrence of error, the cause and solution will be displayed as the warning signal. This allows a smooth resolution of problem. Sensors have been set to monitor the temperature and pressure, which are necessary for data collection. Thus, the management of the production line is also made possible.

Self-drainingWater in the system is being drained out automatically without using valves. This prevents freezing and cracking of pipes during resting periods of the factory when external temperature falls below 0°C. This system can be used even in lines that propylene glycol cannot be used.

Unifying of UnitsControl panel, tank, valve and other units are being unified into this single unit. This saves space and allows speedy operation. High level of durability of the pump unit and cooling tank is made possible with stainless steel.

550055005500

Ecobrid

Page 2: 102-103 ecobrid 2 - MATSUImatsui.net/jp/product/pdf/ecobrid_201506.pdf · Ecobrid H H H Ecodrygel (Cooling Tower) Cooling Water Tank Microgel (Cooling & Heating Unit) Pump Unit Filter

Ecodrygel (Cooling Tower)

Cooling Water Tank

Microgel (Cooling & Heating Unit)

Pump Unit Filter Unit

Cooling fan operating under energy saving mode Recycle pump operating under energy saving mode

Wet BallTemperature Energy saving operation starts up when external temperature drops.

Normal operation

Molding Machine Operating Frequency

Molding Machine Operating Frequency

Energy SavingEnergy Saving

One Cooling Fan Stops

Mold Temperature ControllePperating Frequency Water pump automatically stop with the decline of molding

machine operating frequency.

Solving Water Quality Issues Increasing the Output

The efficiency of a whole factory declines as corrosion builds in pipes.

Keep water pipes clean and clear with the ecobrid.

PMRControl Panel

GPS

EDKGPP KFT

RCM/RCD

7

Temperature C

ontroller

Temp

eratur

e Con

troller

solutions

Page 3: 102-103 ecobrid 2 - MATSUImatsui.net/jp/product/pdf/ecobrid_201506.pdf · Ecobrid H H H Ecodrygel (Cooling Tower) Cooling Water Tank Microgel (Cooling & Heating Unit) Pump Unit Filter

Current Water Cooling System

Water-Cooled Open-Type Water Cooling System

Cooling Tower

Cooling Water Tank

Injection-Molding Machine

Mold Temperature Controller

Chiller

Cooling System that Uses Vaporization

Open-Type Uses Circulating Water

Demerits of Water-Cooled Open-Type Water Cooling System

High consumption level of waterContamination caused by foreign objects

such as oxygen and sand.Difficulties in maintenance of water

quality due to formation of algae and Legionella pneumophiliaNeed for disposal of medicated water

used to clean and improve water quality.High level of energy consumption caused

by high capacity operation of the circulating pump.Decline of cooling performance caused by

deterioration of water qualityAccumulation of impurities in heat

exchangers and pipesFailure of devices due to corrosion and

rustingHalting of production line for regular

maintenance checks.

Environmental Problem

Waste of Energy

Decline of Productivity

Water-Cooled Closed Type Water Cooling System

Cooling Tower

Cooling Water Tank

Injection-Molding Machine

Chiller

Mold Temperature Controller

Demerits of Water-Cooled Closed Type Water Cooling System

Consumption of water for cooling of heat exchanger.Contamination of water and the heat exchanger is caused

by cooling of the heat exchanger with water.Halting of production line for regular maintenance checksConsumption of electricity by the circulating pump of heat

exchanger.

Page 4: 102-103 ecobrid 2 - MATSUImatsui.net/jp/product/pdf/ecobrid_201506.pdf · Ecobrid H H H Ecodrygel (Cooling Tower) Cooling Water Tank Microgel (Cooling & Heating Unit) Pump Unit Filter

37 21

Electricity

Water

30% increase of capacit30% increase of capacity30% increase of capacity

%%

H2O

Reduce CO2 Emission that 21 soccer field sized forestabsorbed in a year

Save USD11,000 yearly from water and electricalbills

Flow Diagram of Air-Cooled Closed Type Water Cooling System ‘Ecobrid’

Ecodrygel (Cooling Tower)

Cooling Water Tank

Injection-Molding Machine

Microgel (Cooling & Heating Unit)

Ecobrid

Upon Using Air-Cooled Open-Type Water Cooling System

Save 8 25m pool worth of water in a year

Save Water

37 tons of CO2 is estimated to be reduced yearly according to ourfindings. This is equivalent to the amount of CO2 that 21 soccerfield sized forest (0.6 hectares) can absorbed in a year.

Cut Cost

Air-Cooled Open-Type Water Cooling System

Air-Cooled Closed Type Water Cooling System 520litres/min181kW

390Litres/min136kW

Reduce CO2 Emission

USD11,000/year37 tons/year3,860tons/year

*Data above are based on actual figures of Kanto area(Japan) in April 2007. Actual figures differ according to weather and usage*Data above represents the results of replacing a Cooling Tower System, for 10 200tons capacity injection-molding machines, with our Ecobrid System.

Current Productivity

Temperature C

ontroller

Temp

eratur

e Con

troller