meps

Upload: kamilo-alvarez

Post on 03-Apr-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/29/2019 MEPS

    1/4

    MEPS - Micro Extraction by Packed Sorbent

    For more information about MEPS - Micro SPE, please refer to pages 222-225.

    Choose your MEPS syringe

    The current range of syringes may be used manually or in autosamplers. To maximizeflexibility, MEPS syringes are supplied without a needle. MEPS BIN (barrel insert needle )options are listed on page 225.

    Syringes | Special Purpose Syringes 57

    Syringes | Special Purpose Syringes

    SyringeVolume

    PTFETippedPlunger

    Autosampler SyringeScale

    Length(mm)

    SyringeBarrel OD

    (mm)

    Replace-ment

    PlungerPart No.

    SyringePart No.

    100 L Agilent Instrument 7693A 54.1 6.5 0318263 005292

    100 L Shimadzu Instruments AOC20i 54.1 6.7 0318274 005293

    100 L CTC Analytics, HTA 300APlus, Thermo Scientific andVarian 8400 systems

    60 6.7 031826 005291

    250 L Agilent Instruments 7693A 54.1 6.5 0318303 006293

    250 L

    Shimadzu Instruments AOC20i 54.1 6.7 0318305 006294250 L HTA 300APlus, Thermo Scientific and Varian 8400

    systems60 6.7 031831 006291

    250 L CTC Analytics systems 60 7.8 0318301 006292

    eVol is ideal for use with MEPS. The eVol custom programming function allows manualMEPS to be automated - the sampling, processing, extraction and injection steps areperformed using the same syringe.

    Refer to pages 21-24 for more information about eVol.

    eVol MEPS

    SyringeVolume

    PTFE TippedPlunger

    Description Replacement PlungerPart No.

    SyringePart No.

    50 L eVol XCHANGE Syringe for MEPS 2910382 2910027

    500 L eVol XCHANGE Syringe for MEPS 2910384 2910026

    Syringes andAccessories

  • 7/29/2019 MEPS

    2/4

    22HPLC Supplies | MEPS Micro SPE 223

    How To Use MEPS

    STEP

    1

    STEP

    2

    STEP

    3

    STEP

    4

    SAMPLING

    (1-N TIMES)

    WASHING ELUTION

    SOLVENT

    INJECTION

    Step 1: Pump the samplethrough the MEPS BIN (oneor more volumes may betaken).

    Step 2: Wash the MEPSBIN once by pumping 20 Lto 50 L of wash solutionthrough the BIN to removeinterferences.

    Step 3: Elute the analyte by

    drawing solvent through theBIN into the syringe barrel.

    Step 4: Inject the analytedirectly into the injector.

    Pump 50 L solvent followedby 50 L wash solution toprepare BIN for the nextsample.

    MEPS Is Reusable

    Like conventional SPE, the number of timesthe cartridge can be reused is dependenton the sample matrix and the cleaning

    regime between elutions. Since only 3mg ofstationary phase is used in MEPS it can be

    washed effectively between each extractionwithout the need for large solvent volumes.For simple applications, MEPSdevices have

    been used successfully for up to 50 cyclesmaking it very cost effective.

    Semi-automation of MEPScan be achieved

    by coupling MEPS syringes to SGEs eVol

    automated analytical syringe to speed uprepetitive SPE and is ideal for rapid method

    development.

    For more information oneVol see pages 22-24.

    MEPS can also be fully automated on

    autosamplers such as the CTC PAL for on-line SPE and injection.

    Method RopivacaineLOD (nM)

    Accuracy (%) Precision (RSD%)(Inter-assay)

    HandlingTime

    MEPS/ GC-MS 2 105 5.0 1 min

    LLE / GC-MS 2 101 3.8 20 min

    SPE / LC-UV 100 101 3.0 20 min

    SPME / GC-MS 5 110 6.3 40 min

    Comparison of accuracy and precision between MEPS and other methods for ropivacaine (local anesthetics).

    MEPS Has Proven Accuracy and Precision Compared to

    Other Sample Preparation Methods

    MEPS Can Be Semi or Fully Automated

    HPLC Supplies andAccessories

  • 7/29/2019 MEPS

    3/4

    This selection guide can be viewed as an electronic book at sge.com/selectionguide

    MEPS micro SPE ormat is ideally suited to previously challenging applications.For an

    example o MEPS used in a orensic application see page 12.

    224

    MEPS Applications and Publications

    Industry Title Author Journal

    Env ironmental Determination o organic priorit y pollutants and emerging

    compounds in wastewater and snow samples using multiresidueprotocols on the basis o microextraction by packed sorbentscoupled to large volume injection gas chromatography-massspectrometry analysis.

    Prieto et al J Chrom A,

    2010, 1217:6002-6011

    Forensic and Pharmaceutical

    Liquid chromatographic analysis o oxcarbazepine and itsmetabolites in plasma and saliva ater a novel microextraction bypacked sorbent procedure.

    Sarac ino et a l Anal Chim Acta,2010, 661: 222-228

    Environmental At-line microextraction by packed sorbent-gas chromatographymass spectrometry or the determination o UV flter andpolycyclic musk compounds in water samples.

    Moeder et a l J Chrom A, 2010,1217:2925-2932

    Forensic Contribution o microextraction in packed sorbent or theanalysis o cotinine in human urine by GCMS.

    Laay et al Anal BioanalChem, 2010,396: 937941

    General Chemistry andLie Science

    Recent advances in microextraction by packed sorbent orbioanalysis.

    Abdel- Rehim J Chrom A,2010, 1217:2569-2580

    Forensic Rapid identifcation and quantifcation o methamphetamine andamphetamine in hair by gas chromatography/mass spectrometrycoupled with micropulverized extraction, aqueous acetylationand microextraction by packed sorbent.

    Miyaguchi et al J. Chrom A,2009, 1216:40634070

    General Chemistry andLie Science

    Fully Automatic Sample Treatment by Integration oMicroextraction by Packed Sorbents into Commercial CapillaryElectrophoresisMass Spectrometry Equipment: Application tothe Determination o Fluoroquinolones in Urine.

    M o r a l e s - C i det al

    Anal. Chem.,2009, 81: 31883193

    Forensic Screening o Cocaine and Its Metabolites in Human UrineSamples by Direct Analys is in Real-Time Source Coupled to Time-o-Flight Mass Spectrometry Ater Online PreconcentrationUtilizing Microextraction by Packed Sorbent.

    Jagerdeo E,Abdel-Rehim M

    J Am Soc MassSpectrom. 2009May;20(5):891-899

    Food and Flavour Determination o 2,4,6-Trichloroanisole and 2,4,6-Tribromoanisolein Wine using Microextraction in Packed Syringe and GasChromatographyMass Spectrometry.

    Jnsson et al J. Agric. FoodChem., 2008,56: 49624967

    General Chemistry Study o the actors aecting the perormance o microextractionby packed sorbent (MEPS) using liquid scintillation counter andliquid chromatography-tandem mass spectrometry.

    Altun andAbdel-Rehim

    Anal Chim Acta.2008, 630:116-123

    Pharmaceutical MEPSas a rapid sample preparation method to handle unstablecompounds in a complex matrix: determination o AZD3409 inplasma samples utilizing MEPS-LC-MS-MS.

    Abdel-Rehim Met al

    J ChromatogrSci. 200846:518-523

    Pharmaceutical and

    Lie Science

    Rapid and Sensitive Method or Determination o

    Cyclophosphamide in Patients Plasma Samples UtilizingMicroextraction by Packed Sorbent Online with LiquidChromatography-Tandem Mass Spectrometry (MEPS-LC-MS/MS).

    Said et al J. Liquid Chro-

    matography &Related Tech-nologies 2008,31: 683694

    HPLC Supplies andAccessories

  • 7/29/2019 MEPS

    4/4

    HPLC Supplies | MEPS Micro SPE 225

    Description For Use withMEPS Syringe P/N

    # per Pack Part No.

    MEPS

    BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systemsC18 005291 and 006291 5 2900101

    Silica 005291 and 006291 5 2900102

    C8+SCX* 005291 and 006291 5 2900103

    C2 005291 and 006291 5 2900104

    C8 005291 and 006291 5 2900106

    MEPS Development kit (contains 1 each of C18, C8, C2, SI LICA and C8+SCX) 005291 and 006291 1 2900105

    MEPS BIN for CTC Analytics systems using 250 L syringes

    C18 006292 5 2900301

    Silica 006292 5 2900302

    C8+SCX* 006292 5 2900303

    C2 006292 5 2900304

    C8 006292 5 2900306

    MEPS Development kit (contains 1 each of C18, C8, C2, SILICA and C8+SCX) 006292 1 2900305

    MEPS BIN for Agilent systems

    C18 005292 and 006293 5 2900601

    Silica 005292 and 006293 5 2900602

    C8+SCX* 005292 and 006293 5 2900603

    C2 005292 and 006293 5 2900604

    C8 005292 and 006293 5 2900606

    MEPS Development kit (contains 1 each of C18, C8, C2, SI LICA and C8+SCX) 005292 and 006293 1 2900605

    MEPS BIN for Shimadzu systems

    C18 005293 and 006294 5 2900601

    Silica 005293 and 006294 5 2900602

    C8+SCX* 005293 and 006294 5 2900603

    C2 005293 and 006294 5 2900604

    C8 005293 and 006294 5 2900606

    MEPS Development kit (contains 1 each of C18, C8, C2, SI LICA and C8+SCX) 005293 and 006294 1 2900605

    MEPS Barrel Insert and Needle (BIN) Assembly OptionsFor GC applications, needle is 23 gauge, 0.63 mm OD, Cone point style.

    Description For Use with

    MEPS Syringe P/N

    # per Pack Part No.

    MEPS BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems

    C18 005291 and 006291 5 2900401

    Silica 005291 and 006291 5 2900402

    C8+SCX* 005291 and 006291 5 2900403

    C2 005291 and 006291 5 2900404

    C8 005291 and 006291 5 2900406

    SCX 005291 and 006291 5 2900408

    SAX 005291 and 006291 5 2900409

    MEPS Development kit (contains 1 each of C18, C8, C2, SI LICA and C8+SCX) 005291 and 006291 1 2900405

    MEPS BIN for CTC Analytics systems using 250 L syringe

    C18 006292 5 2900501

    Silica 006292 5 2900502

    C8+SCX* 006292 5 2900503

    C2 006292 5 2900504

    C8 006292 5 2900506SCX 006292 5 2900508

    SAX 006292 5 2900509

    MEPS Development kit (contains 1 each of C18, C8, C2, SILICA and C8+SCX) 006292 1 2900505

    For LC Applications, needle is 22 gauge, 0.72 mm OD.

    Base material is silica with mean particle size of 45 m and pore size of 60 . *C8+SCX BINS are labelled as M1.

    Description # per Pack Part No.

    100 L Removable needle MEPS syringe for CTC Analytics, HTA 300A Plus & Varian 8400 systems. 1 005291

    Replacement plunger assembly for 005291. 1 031826

    250 L Removable needle MEPS syringe for CTC Analytics, HTA 300A Plus & Varian 8400 systems. 1 006291

    Replacement plunger assembly for 006291. 1 031831

    250 L Removable needle MEPS syringe for CTC Analytics systems. 1 006292

    Replacement plunger assembly for 006292. 1 031831100 L Removable needle MEPS syringe for Agilent systems. 1 005292

    Replacement plunger assembly for 005292. 1 0318263

    250 L Removable needle MEPS syringe for Agilent systems. 1 006293

    Replacement plunger assembly for 006293. 1 0318303

    100 L Removable needle MEPS syringe for Shimadzu systems. 1 005293

    Replacement plunger assembly for 005293. 1 0318274

    250 L Removable needle MEPS syringe for Shimadzu systems. 1 006294

    Replacement plunger assembly for 006294. 1 0318305

    MEPS Syringe OptionsAll syringes may be used manually as well as with the listed autosamplers.

    HPLC Supplies andAccessories