Page 1: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

1

Stripe 400/600

•Removing and Installing Printhead

•Printhead Resistance Calibration

•Toggle Position Adjustment

Page 2: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

2

Removing the Printhead1. Turn the power

switch off.

2. Disconnect the power cord.

3. Disconnect the printer communications cable.

4. Carefully open the right side cover first and then open the front cover.

5. Make sure you are appropriately grounded using proper anti-static procedures.

Printer Communications

Cable

Anti-Static Device

Right Side Cover

Left Side Cover

Front Cover

Power Cord

Page 3: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

3

1. Open the Printhead lever and raise. Printhead Assembly.

2. Remove media and ribbon (if applicable). Printhead Lever

MediaPrinthead Assembly

Page 4: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

4

Remove strip plate from the front of the Printhead Assembly by unscrewing the two Phillips head screws.

Strip Plate

Page 5: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

5

Using a 7/32 open-ended wrench, remove the two nuts fastening the Printhead to the Printhead Assembly.

Remove the two

fastening nuts.

Page 6: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

6

1. Carefully lower Printhead bracket away from Printhead Assembly, detaching the guide pins from the alignment slots found in the Printhead Assembly.

2. Slowly pull Printhead forward to expose the Printhead Cable Assembly.

PrintheadBracket

PrintheadAssemblyPrinthead Cable

Assembly

Page 7: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

7

1. Carefully disconnect the Printhead Assembly Cable from the Printhead Assembly.

2. Remove the Printhead.

Printhead CableAssembly

Printhead Bracket

PrintheadAssembly

Page 8: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

8

Installing the Printhead

1. Turn the power switch off and make sure both the power cord and the printer communications cable are disconnected.

2. Open the side cover first, then the front cover.3. Open the Printhead lever.4. Make sure to note the new Printhead resistance before

installing. See calibration instructions.

Resistance

Print Line

Page 9: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

9

Position the Printhead under the Printhead Assembly and connect the Printhead Assembly cable into the appropriate connector.

Printhead BracketGuide Pins

Page 10: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

10

1. Attach the strip plate to the front of the Printhead Assembly by tightening the two Phillips head screws.

2. Install media and ribbon (if applicable).

After confirming the Printhead Cable Assembly is properly positioned into the Printhead connector, attach the two 7/32 hex nuts onto the Printhead bracket guide pins.

Page 11: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

11

1. Clean the Printhead’s print-line using an alcohol swab, removing oil or dirt that may have been deposited during installation.

2. Lower the Printhead Assembly and close Printhead lever, checking the media and ribbon for proper alignment.

3. Carefully close front cover first, then the side cover.

Page 12: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

12

Printhead Resistance Calibration

Printhead voltage should never be adjusted to affect print darkness. Changing Printhead voltage in this way will drastically reduce the life of the Printhead.

Page 13: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

13

Disengage Printer’s left panel by removing three connecting screws

Voltmeter/Multimeter

Three Panel Screws

Page 14: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

14

1. Plug in power cord and printer communications cable.2. With the printer turned off, attach the black probe of the

voltmeter to Ground (GND) on the logic board, and the red probe to the top of point F2 (the bottom-left fuse).

Red Probe (Positive) Touching

F2

Power Switch

Black Probe (Negative) Touching

Ground (GND)

Page 15: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

15

1. Turn the voltmeter/multimeter switch to VDC 200.2. Without removing the probes, turn the power on and wait for the

Power On Self-Test to be completed (usually takes between 10-15 seconds).

3. Find RV2 at the very bottom of the Main Logic Board and adjust with a small Phillips-head screwdriver until the voltmeter displays the correct value from Table 1 (as defined by the resistance value for this particular Printhead).

Ground

RV2

F2

Table 1

Page 16: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

16

Resistance Voltage VDC Resistance Voltage VDC935 - 945 Ω 22.2 680 - 688 Ω 22.2

945 - 963 22.4 689 - 701 22.4964 - 981 22.6 702 - 714 22.6982 - 999 22.8 715 - 727 22.8

1000 - 1017 23.0 728 - 740 23.01018 - 1035 23.2 741 - 754 23.21036 - 1053 23.4 755 - 767 23.41054 - 1072 23.6 768 - 781 23.61073 - 1091 23.8 782 - 794 23.81092 - 1110 24.0 795 - 808 24.01111 - 1129 24.2 809 - 822 24.21130 - 1148 24.4 823 - 836 24.41149 - 1168 24.6 837 - 850 24.61169 - 1187 24.8 851 - 864 24.81188 - 1207 25.0 865 - 879 25.01208 - 1227 25.2 880 - 893 25.21228 - 1247 25.4 894 - 908 25.41248 - 1265 25.6 909 - 920 25.6

S400 S600

Printhead Voltage Adjustment Table

Table 1

After voltage is Properly adjusted, Re-attach left panel with the three connecting screws.

Page 17: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

17

Toggle Position Adjustment

1. Before adjusting toggle pressure, perform a Pause Self-Test by holding the pause key while turning on power. If the print is not consistent across the width of the label, proceed to make toggle adjustments.

2. Turn the toggle adjusting nuts until appropriate pressure is achieved.a. Tighten (clockwise) to

increase pressure.b. Loosen (counter-

clockwise) to decrease pressure.Note that too much pressure applied to the toggles will

shorten the life of the Printhead. Choose the lowest even pressure that produces the desired print quality in order to maximize Printhead life.

Page 18: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

18

Examples of uneven toggle pressure versus even pressure

Uneven Pressure

Even Pressure

Page 19: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

19

Platen Roller Replacement

•Removing Control Panel Cover

•Main Logic Board Detachment

•Media Sensor Assembly Removal

•Tear-Off Plate Removal

•Platen Roller Removal & Installation

Page 20: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

20

Removing Control Panel Cover

1. Turn power off and disconnect power cord and printer communications cable.

2. Remove media and ribbon (if applicable).

3. Remove the right, left, and front cover.

4. Make sure you are appropriately grounded using proper anti-static procedures.

Page 21: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

21

1. Disconnect the Control Panel data connector from the Main Logic Board.

Control PanelData Connector

Page 22: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

22

1. Detach the Control Panel Cover by removing the attachment screw.

2. Carefully lift the bottom of the control panel cover and pull cover away from the front of the printer.

Attachment Screw

Control Panel Cover

Page 23: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

23

Note where the data connectors are attached to the Main Logic Board.

1. Disconnect all of the data connectors from the Main Logic Board.

Removing the Main Logic

Board

Page 24: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

24

1. Remove Ground Strap and the three logic board fastening screws.

Ground Strap

Page 25: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

25

To detach Main Logic Board from the power supply connector below it, firmly grip board on both sides and pull it upward, carefully rocking it side to side in order to loosen it.

Power Supply

Connector

Page 26: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

26

Detach the Upper Media Guide by sliding it away from the right side of the printer.

Upper Media Guide

Page 27: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

27

1. Unscrew the two attachment screws that hold the Media Sensor in place.

2. Remove the Media Sensor Assembly.

Media Sensor

Assembly

Attachment

Screws

Page 28: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

28

Tear-Off Plate Removal

1. Remove the two Tear-Off Plate screws.

2. Grasping the bottom of the Tear-Off Plate, disengage it by pushing it up and pulling it away from the front of the printer.

Page 29: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

29

Platen Roller Removal

Platen Pulley

Main Driv

e Belt

Ground Chain

Idler Pulley

Page 30: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

30

1. Loosen the Idler Pulley bolt.

2. Gently side the Idler Pulley downward, releasing tension from the Main Drive Belt.

Page 31: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

31

1. Disengage Main Drive Belt from the three pulleys.

2. Using a hex wrench, loosen the platen pulley hex screw that secures the platen pulley to the platen roller.

3. Remove the platen pulley.4. Detach the ground chain from the platen roller

bar.

Page 32: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

32

1. Lift up the left end of the platen roller and carefully slide the platen bearing off of the metal platen roller bar.

2. Disengage the platen roller by lifting up the side with the platen pulley and shifting the right platen bearing to the left, removing it from the bearing opening.

3. Remove the platen roller.Left Platen

Bearing and

Spacer

Page 33: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

33

Platen Roller Installation

1. Slide the platen bearing off the pulley side of the platen roller.

2. Insert the right side of the platen roller into the bearing opening.

Page 34: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

34

* Make sure that the bearings are rotated correctly for either the S400 or the S600. For the S400, the bearing groove should be on the bottom. The S600 rotates the bearings 180 degrees (the bearing groove is toward the top).

S600S400

Bearing

Groove

Page 35: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

35

Once the right side of the platen roller is correctly inserted into the right bearing opening, slide the left bearing onto the Platen roller bar and lower it into the left bearing dropout.

Page 36: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

36

1. Attach the Ground Chain.2. Attach the platen pulley to the Platen roller bar,

tightening the platen pulley hex screw until it is snug.

Platen Pulley

Platen Roller Bar

Page 37: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

37

1. Make sure that the Idler Pulley is loose and pulled downward.

2. Set up the Main Drive Belt around the three pulleys.

3. Increase Main Drive Belt tension by sliding the Idler Pulley up until tension is correct.

Page 38: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

38

Tighten the hex bolt to secure Idler Pulley against printer.

Idler Pulley

Platen Pulley

Ground Chain

Page 39: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

39

Reinstall the Media Sensor Assembly by inserting it through the right side of the printer and securing with the two screws. Slide the media guide into the Media Sensor Assembly slot.

Media Sensor

Assembly Slot

Page 40: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

40

Install the Main Logic Board, making sure all the power supply connector pins line up with the connector pins at the bottom of the board. Push the board down into place (rocking the board from side to side may be necessary).

Logic Board

Connector

Page 41: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

41

Attach all of the data connectors to the Main Logic Board. Secure Logic board into place with the three screws (making sure the top screw also connects the grounding strap underneath).

Grounding Strap

and Screw

Page 42: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

42

1. Attach the tear-off plate to the front of the printer by inserting the metal legs into the tear-off plate notches and push it down into place. Fasten it with two screws.

2. Reattach the control panel and fasten it with the two screws. Attach the Control Panel cable to the Main Logic Board.

3. Install the media and ribbon (if applicable).

Page 43: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment

43

1. Attach the right, left and front cover.

2. Connect the power cord and the printer communications cable.

Page 44: 1 Stripe 400/600 Removing and Installing Printhead Printhead Resistance Calibration Toggle Position Adjustment