Introduction

Hardware data configuration is the first step of SAU data

configuration.

After this course, trainees will understand HLR9820 hardware

in-depth.

Page 3: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 3All rights reserved

Upon completion of this course, you

will be able to:

Master the hardware& local office

data configuration.

Master all the logical NO. principle.

Page 4: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 4All rights reserved

Chapter 1 Basic conceptsChapter 1 Basic concepts

Chapter 2 Data configurationChapter 2 Data configuration

Chapter 3 Relative maintenance commandChapter 3 Relative maintenance command

Chapter 4 Configuration exampleChapter 4 Configuration example

Page 5: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 5All rights reserved

HLR9820 data works for: SAU (Signaling Processing)

HDU (MAP Services Processing)

The data is configured in: LMT (For SAU)

Hardware Data

Local Office Information

Signaling Data

SMU Client (For HDU)

Global Data

Where is the data configured?

Page 6: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 6All rights reserved

Chapter 1 Basic conceptsChapter 1 Basic concepts

1.1 Elements and position1.1 Elements and position

1.2 Module1.2 Module

1.3 Preparations1.3 Preparations

1.4 Data config. sequence1.4 Data config. sequence

Page 7: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 7All rights reserved

Elements and position

Module structure

HLR9820

Cabinet Cabinet

Frame Frame

Board Board

Page 8: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 8All rights reserved

Elements and position

Cabinet

HLR9820 has 1 or 2 cabinets.

Page 9: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 9All rights reserved

Elements and position

Frame and board

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

W B S G

W C C U

W C C U

W B S G

W I F M

P S M

W C S U

W C S U

W S M U

W H S C

W E P I

W E P I

W S I U

W C K I

W C K I

W B F I

W B F I

W S I U

W S I U

Front

Back

W I F M

W S M U

P S M

P S M

P S M

SAU has two kinds of frames:

basic frame and expansion frame.

There are 1 basic and two

expansion frames in full

configuration.

Only IBM solution has expansion

frame. It depends on numbers of

subscriber.

Front board and back board

Page 10: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 10All rights reserved

Elements and position

Type and function of the boards

Front board Back boardWSMU System Management Board WSIU System Interface Board

WCCU Call Control Board - -

WEAM E1 ATM forward WEPI ATM Interface Board

WCSU Call Control and Signaling Processing Board

WEPI E1 Interface Board

WBSG Broadband Signaling Processing Board

- -

WIFM IP Transferring Module Board WBFI Back Far End Interface Board

WALU Alarm Board

PSM Power Supply Board PSM Power Supply Board

- - WHSC Hot-swap Control Board

- - WCKI Clock Interface Board

Page 11: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 11All rights reserved

Elements and position

Number of devices

To help in recognizing all categories of module components, it is necessary to number those of the same category uniformly.

Shelf number To recognize individual shelves easily, each shelf is given a number, called shelf number. The shelf with the basic frame is numbered as Shelf 0.

Page 12: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 12All rights reserved

Elements and position

Number of devices

Frame number

The system can support ten frames at most, numbering from 0 to 9. The basic frame in the integrated configuration shelf is numbered as Frame 0.

Page 13: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 13All rights reserved

The 8-bit Dual Inline Package (DIP) S3 of SIU is provided for setting frame numbers. The corresponding setting table is shown in follow

Elements and position

DIP

Frame No.

8 7 6 5 4 3 2 1

0 on on on on on on on on

1 on on on on on on on off

2 on on on on on on off on

3 on on on on on on off off

4 on on on on on off on on

5 on on on on on off on off

6 on on on on on off off on

7 on on on on on off off off

8 on on on on off on on on

9 on on on on off on on off

Page 14: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 14All rights reserved

Slot number

Slot number is used to identify the slot of a specific

board that is inserted into a frame.

Each frame contains 21 slots at most (No. from 0 to

20)

Elements and position

Page 15: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 15All rights reserved

Chapter 1 Basic conceptsChapter 1 Basic concepts

1.1 Elements and position1.1 Elements and position

1.2 Module1.2 Module

1.3 Preparations1.3 Preparations

1.4 Data config. sequence1.4 Data config. sequence

Page 16: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 16All rights reserved

Module

Module number

Module number is set according to the type of the board

and is numbered from 2.

Modules of the same board are numbered uniquely. Here

are the numbering rules:

WSMU Module number: 2~21

WCCU/WCSU Module number: 22~101

WEAM/WIFM/WBSG Module number: 132~211

Page 17: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 17All rights reserved

Chapter 1 Basic conceptsChapter 1 Basic concepts

1.1 Elements and position1.1 Elements and position

1.2 Module1.2 Module

1.3 Preparations1.3 Preparations

1.4 Data config. sequence1.4 Data config. sequence

Page 18: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 18All rights reserved

Preparations

Before the data configuration, you should know

The networking and configuration conditions

The requirements put forward during engineering design

stage

The local office information (SPC/HLR No./CC etc.)

Page 19: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 19All rights reserved

Common MML commands

Command Function

ADD Add database data

MOD Modify database data

RMV Delete database data

LST Query database data

DSPQuery status of related equipment and resource

SET Set data or status

LOF Start offline mode

LON Start online mode

Page 20: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 20All rights reserved

Offline

Command or step Function

LOF Start the offline mode

SET CWSON: SWT=OFFSet the alarm output switch of the current workstation to OFF

SET FMT: STS=OFF Set format status to OFF

If it is the initial data configuration for the deployment:

Page 21: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 21All rights reserved

Online

Command or step Function

LON Start the online mode

SET CWSON: SWT=ON Set the alarm output switch of the current workstation to ON

SET FMT: STS=ON Set format status to ON

FMT Format all data of all modules

Loading data in power-down statusRemove two Wireless System Management Units (WSMUs) to simulate equipment power-down and then load data.

After that, how to load the data to switch?

Page 22: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 22All rights reserved

Chapter 1 Basic conceptsChapter 1 Basic concepts

1.1 Elements and position1.1 Elements and position

1.2 Module1.2 Module

1.3 Preparations1.3 Preparations

1.4 Data config. sequence1.4 Data config. sequence

Page 23: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 23All rights reserved

HLR9820 Data Configuration Sequence

Start

End

Configure local office information

Configure signaling data

Configure hardware data

Start

End

Configure local office information

Configure signaling data

Configure hardware data

Page 24: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 24All rights reserved

Questions

What’s the numbering principle of shelf, fr

ame, board?

Which board has module number?

Can boards in same module exist in differ

ent frames?

What’s the difference of online and offline

mode?

Page 25: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 25All rights reserved

Chapter 1 Basic conceptsChapter 1 Basic concepts

Chapter 2 Data configurationChapter 2 Data configuration

Chapter 3 Relative maintenance commandChapter 3 Relative maintenance command

Chapter 4 Configuration exampleChapter 4 Configuration example

Page 26: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 26All rights reserved

Chapter 2 Data configurationChapter 2 Data configuration

2.1 Configuration Flow2.1 Configuration Flow

2.2 Data configuration2.2 Data configuration

Page 27: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 27All rights reserved

Configuration Flow

Add ShelfAdd Shelf

Add FramesAdd Frames

Add BoardsAdd Boards

Add WCSUAdd WCSU Add WCKIAdd WCKI

Add WIFMAdd WIFM

Add WEPIAdd WEPI

Conf. E1Conf. E1

Conf. clock ModeConf. clock Mode

Conf. FEConf. FEConf. CPCConf. CPC

Conf. MEMConf. MEM

Clock Refer.Clock Refer.

Add WCCUAdd WCCU

Set Local OfficeInformation

Set Local OfficeInformation

Page 28: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 28All rights reserved

Configuration Flow for ATM

Add ShelfAdd Shelf

Add FramesAdd Frames

Add BoardsAdd Boards

Add WEAMAdd WEAM Add WCKIAdd WCKI

Add WEPIAdd WEPI

Conf. IMA/UNIConf. IMA/UNI

Conf. clock ModeConf. clock Mode

Conf. MEMConf. MEM

Clock Refer.Clock Refer. Conf. PVCConf. PVC

Add WCCUAdd WCCU

Conf. E1Conf. E1

Set Local OfficeInformation

Set Local OfficeInformation

Page 29: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 29All rights reserved

Chapter 2 Data configurationChapter 2 Data configuration

2.1 Configuration Flow2.1 Configuration Flow

2.2 Data configuration2.2 Data configuration

Page 30: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 30All rights reserved

Commands

Adding Shelf

Adding Frame

Adding Board

Adding E1

Setting Clock Mode

Adding Board Clock Reference Source

Adding FE Configuration

Adding MEM Configuration

Adding IMA group

Adding IMA link

Adding UNI link

Adding PVC link

Set Local Office Information

Page 31: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 31All rights reserved

Shelf/Frames/Boards

Relationship

[Shelf Number][Location Title][Position Number][RoW Number][Column Number]

ADD SHF

[Frame Number][Shelf Number][Position Number]

ADD FRM

[Frame Number][Slot Number][Location]

ADD BRD

Page 32: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 32All rights reserved

Shelf/Frames/Boards

Add Shelf

For HLR9820 SAU, there is only one shelf. The number always is 0.

Page 33: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 33All rights reserved

Shelf/Frames/Boards

Add Frames

• For SUN solution, there is only one frame. The frame number is always 0.• For IBM Solution, there are three frames at maximum configuration. The frame number are from 0 to 2.

Page 34: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 34All rights reserved

Shelf/Frames/Boards

Add Boards

Before adding the boards, the frame and shelf to which the

boards belong must have already been added.

WSMU/WALU/PSM will be added automatically after the

frame has been added.

If parameters need to be modified, please delete the board

at first then add it again.

Two pieces of CPC will be added automatically after the

WCSU has been added.

Page 35: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 35All rights reserved

Add E1

Configure the WEPI if the module needs to process the SS7.

Page 36: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 36All rights reserved

Set Clock Mode

Only for TDM/ATM networking

SET CKICFG: CL=LEVEL2, WM=MANUAL, MCS=LCK1;

Page 37: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 37All rights reserved

Board Clock Reference Source

Only for TDM/ATM networking

After configuring clock mode

Parameter indicate the physical position:• Frame No.• Slot No.• E1 No.

Page 38: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 38All rights reserved

Add FE configuration

Function:

WIFM/WBFI is the interface between SAU and IP network.

They process MAC and IP protocol.

WIFM deliver IP package to WBSG.

We need setup FE (Fast Ethernet) interface for signaling

traffic.

Page 39: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 39All rights reserved

Add MEM configuration

Function:

Setup the connection between SAU and HDU

Page 40: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 40All rights reserved

WCSU/WCCU

WHSC0

WHSC1

HDU1#

HDU2#

LAN

SWITCH

LAN

SWITCH

WCSU/WCCU

MODULE

Hardware Connection

Page 41: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 41All rights reserved

Command

ADD MEMCFG

Module: Module No. of WCCU/WCSU.

Local IP address: IP of WCSU. it is defined by this command.

Remote IP address: IP of HDU. Come from HDU.

Remote Port: IP port of HDU, always be 16500.

MEM Configuration

Page 42: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 42All rights reserved

Command

ADD IMAGRP

WEAM Module: Module No. of .WEAM

IMA Group No.: Number of IMA group, ranging from 0 to 7.

Add IMA group

Page 43: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 43All rights reserved

Command

ADD IMALNK

WEAM Module: Module No. of WEAM

IMA Group No.: Number of IMA group, ranging from 0 to 7.

IMA link port no: Number of the E1 port added to the IMA group

Add IMA link

Page 44: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 44All rights reserved

Command

ADD UNILNK

WEAM Module: Module No. of WEAM

UNI link port no: Number of the E1 port added to the IMA group

Add UNI link

Page 45: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 45All rights reserved

Command

ADD PVCLNK

PVC link number: Number of the global PVC links

VPI: Virtual path identifier (VPI)

VCI: virtual channel identifier (VCI)

Signal distribution module number:

Signal handle module number:

IMA group number:

UNI port number:

Add PVC link

Page 46: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 46All rights reserved

Command

Set OFI

Signaling point code (SPC)

Signaling network where the local office resides (NI)

Network Structure

Whether the local office is a signaling transfer point (STP)

Add OFI

Signaling point code (SPC)

Set Local Office Information

Page 47: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 47All rights reserved

Questions

What’s the sequence for hardware data conf.?

Which board will be added automatically after a

frame has been added?

How to make the data active in switch after we

configure the data offline?

What conditions are needed for E1 configuration?

Page 48: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 48All rights reserved

Answer

1 Add shelf-> Add frame-> Add board->others

2 WSMU , WALU 和 PSM 。 Use FMT to format data. Use LON to set online. Then lo

ad it.

We need add WCSU and WEPI at first.

Page 49: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 49All rights reserved

Chapter 1 Basic conceptsChapter 1 Basic concepts

Chapter 2 Data configurationChapter 2 Data configuration

Chapter 3 Relative maintenance commandChapter 3 Relative maintenance command

Chapter 4 Configuration exampleChapter 4 Configuration example

Page 50: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 50All rights reserved

3.1 Query Hardware3.1 Query Hardware

3.2 Query clock reference3.2 Query clock reference

3.3 Query E1/CPC configuration3.3 Query E1/CPC configuration

3.4 Query IP link3.4 Query IP link

3.5 Query IMA/UNI link3.5 Query IMA/UNI link

3.6 Query Port Status3.6 Query Port Status

3.7 Query Local Office3.7 Query Local Office

Chapter 3 Chapter 3 Relative maintenance commandRelative maintenance command

Page 51: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 51All rights reserved

Query The Hardware

LST SHF

Example: LST SHF: SN=0;

LST FRM

Example: LST FRM: FN=0, SN=0;

DSP FRM

Example: DSP FRM: FN=0;

Page 52: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 52All rights reserved

Query The Hardware

LST BRD

Example: LST BRD: FN=0, SN=0, LOC=FRONT;

DSP BRD

Example: DSP BRD: FN=0, SN=0, PSN=FB;

Page 53: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 53All rights reserved

Query clock reference

LST CKICFG

Example: LST CKICFG:;

DSP CLKPH

Example: DSP CLKPH: FN=0;

DSP BRD (Query status of clock reference)

Example: DSP BRD: FN=0, SN=13, PSN=BB;

Page 54: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 54All rights reserved

Query E1/CPC configuration

LST EPICFG

Example: LST EPICFG: FN=0, SN=0;

DSP BRD

Example: DSP BRD: FN=0, SN=0, PSN=BB;

Display E1 status

Example: DSP PORT: FN=0, SN=0, PT=E1, E1PN=2;

LST CPCCFG

Example: LST CPCCFG: FM=22, LOC=UPMC;

Page 55: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 55All rights reserved

Query IP link

List FE configuration

Example: LST FECFG: MN=134;

Display FE status

Example: DSP PORT: FN=0, SN=10, PT=FE, FEPN=2;

Page 56: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 56All rights reserved

Query IMA/UNI link

List IMA link configuration

Example: LST IMALNK: MN=132, IGN=1, IPN=0;

Display IMA link status

Example: DSP IMALNK: MN=132, IGN=1, IPN=0;

List UNI link configuration

Example: LST UNILNK: MN=133;

Display UNI link status

Example: LST UNILNK: MN=133;

Page 57: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 57All rights reserved

Query Port Status (MEM FE)

To check connection between SAU and HDU

List MEMFE link configuration

Example: LST MEMCFG: MN=22;

Display MEMFE link status

Example: DSP MEMFE: MN=22;

Page 58: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 58All rights reserved

Query Local Office Information

List local office information

Example: LST OFI;

Page 59: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 59All rights reserved

Questions

What’s the difference between LST and DSP?

Which command is to check current clock reference?

Page 60: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 60All rights reserved

Answer

LST is for query static data; DSP is for query the status of

frame/board etc.

DSP BRD is used to check current clock reference. (Board is

active WCKI)

Page 61: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 61All rights reserved

Summary After hardware data

configuration, please load it to

switch. Then query whether the

status of hardware is normal.

Page 62: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 62All rights reserved

Chapter 1 Basic conceptsChapter 1 Basic concepts

Chapter 2 Data configurationChapter 2 Data configuration

Chapter 3 Relative maintenance commandChapter 3 Relative maintenance command

Chapter 4 Configuration exampleChapter 4 Configuration example

Page 63: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 63All rights reserved

Example for hardware

IP address of WIFM: 191.169.100.10;

Mask: 255.255.0.0;

Gateway: 191.169.1.2 。

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

W

C

S

U

W

C

S

U

W

C

C

U

W

C

C

U

W

E

A

M

W

E

A

M

W

S

M

U

W

S

M

U

W

I

F

M

W

I

F

M

W

B

S

G

W

B

S

G

W

A

L

U

P

S

M

P

S

M

Page 64: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 64All rights reserved

Item Configuration data

Signaling pointNetwork Identify Network structure SPC

National 24bits EE0

Mobile network

information

Local GT Country code Area code

8613807550000 86 755

MAP information

Support of USSD function value

MAP version 0902620Not support CAMEL phrase 1

Maximum times of Call Forward

True False False 3

Support of Message waiting information

Cancel SCRepetition times of ALERT_SC fail

Forwarded area limitation

True False 3 NORESTRICTION

Number structure limitation

MAP versionAnytime interrogation support

Support of PSI value

NORESTRICTION GSM PHASE2 True True

Support of GPRS short message

True

Example

Page 65: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 65All rights reserved

Example for hardware

1 set offline mode

Offline------------------------LOF:;

Turn off alarm switch------------------------SET CWSON: SWT=OFF;

Turn off format switch------------------------

SET FMT: STS=OFF;

Page 66: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 66All rights reserved

Example for hardware

2 Add Hardware

Add shelf------------------------ADD SHF: SN=0, LT="HW_TC", PN=0, RN=0, CN=0;

Add frame------------------------ADD FRM: FN=0, SN=0, PN=2, CF=YES;

Page 67: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 67All rights reserved

Add WCSU board------------------------ADD BRD: FN=0, SN=0, LOC=FRONT, BT=WCSU, MN=22, ASS=1;

Add WEAM board------------------------ADD BRD: FN=0, SN=4, LOC=FRONT, BT=WEAM, MN=140, LNKT=LINK_2M;ADD BRD: FN=0, SN=5, LOC=FRONT, BT=WEAM, MN=141, LNKT=LINK_2M;

Example for hardware

Page 68: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 68All rights reserved

Add WEPI board

------------------------

ADD BRD: FN=0, SN=0, LOC=BACK, BT=WEPI;

ADD BRD: FN=0, SN=1, LOC=BACK, BT=WEPI;

ADD BRD: FN=0, SN=4, LOC=BACK, BT=WEPI;

ADD BRD: FN=0, SN=5, LOC=BACK, BT=WEPI;

Add WIFM board

------------------------

ADD BRD: FN=0, SN=10, LOC=FRONT, BT=WIFM, MN=132, ASS=11;

Example for hardware

Page 69: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 69All rights reserved

Add WCCU board

------------------------

ADD BRD: FN=0, SN=2, LOC=FRONT, BT=WCCU, MN=23, ASS=3;

Add WBSG board

------------------------

ADD BRD: FN=0, SN=12, LOC=FRONT, BT=WBSG, MN=133;

ADD BRD: FN=0, SN=13, LOC=FRONT, BT=WBSG, MN=134;

Example for hardware

Page 70: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 70All rights reserved

Add WCKI board

------------------------

ADD BRD: FN=0, SN=13, LOC=BACK, BT=WCKI;

ADD BRD: FN=0, SN=15, LOC=BACK, BT=WCKI;

Example for hardware

Page 71: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 71All rights reserved

Example for hardware

3 : Configure E1/CPC/FE/ATM data

Configure E1 info

------------------------

ADD EPICFG: FN=0, SN=0, LC=CLK_8KA, E0=CRC4, E1=DF,

E2=DF, E3=DF, E4=DF, E5=DF, E6=DF, E7=DF, BM=BALANCE;

Configure CPC info

------------------------

MOD CPCCFG: FM=22, LOC=UPMC, LTYPE=LINK_64K;

Page 72: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 72All rights reserved

Configure clock reference------------------------------SET CKICFG: CL=LEVEL2, WM=AUTO, B1P=L1, B2P=L2, L1P=L3, L2P=L4, B1CST=CLK_2M, B2CST=CLK_2M;

Configure clock from E1------------------------------ADD BOSRC: FN=0, SN=0, EN=2;

Example for hardware

Configure FE------------------------ADD FECFG: MN=132, IP="191.169.100.10", MSK="255.255.0.0", DGW="191.169.1.2";

Page 73: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 73All rights reserved

Configure IMA link

------------------------

ADD IMAGRP: MN=140, IGN=0, IID=0, IVR=VER1.1;

ADD IMALNK: MN=140, IGN=0, IPN=0;

Configure PVC link

------------------------

ADD PVCLNK: PLN=0, VPI=2, VCI=4, SDMN=140, SHMN=133,

BT=IMA;

Example for hardware

Page 74: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 74All rights reserved

Example for hardware

4: Set Local Office Data

Online

------------------------

SET OFI: OFN="HLR-TEST", LOT=CMPX, NN=YES, SN1=NAT,

SN2=NAT, SN3=NAT, SN4=NAT, NPC=“EE00", NNS=SP14, STP=NO,

LAC=K‘755, LNC=K‘86, LOCGT=“861380755",

NETTYPE=GSM/PSTN;

Page 75: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 75All rights reserved

Example for hardware

5: Format the data, load it

Online------------------------LON:;Turn on alarm switch------------------------SET CWSON: SWT=ON;Turn on format switch------------------------SET FMT: STS=ON;Format the data------------------------FMT:;Load the module one by one

Page 76: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

HUAWEI TECHNOLOGIES CO., LTD. Page 76All rights reserved

Summary

After finish hardware data, trainees need

master the basic concepts of hardware.

Trainees need understand the steps of

SAU hardware data configuration

Page 77: 03-HLR9820 SAU Hardware & Local Office Data ISSUE2.2

www.huawei.com

Thank You