zumlink™ - freewave · 2020. 4. 10. · 2 interrupt input ttl ttl interruptisusedtoplacethe...

99
Part Number: LUM0075AA Revision: Jun-2018 ZumLink™ Covers Model: Z9-C or Z9-T Firmware 1.0.7.0 User & Reference Manual

Upload: others

Post on 28-Mar-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Part Number: LUM0075AARevision: Jun-2018

ZumLink™Covers Model: Z9-C or Z9-T

Firmware 1.0.7.0

User & Reference Manual

Page 2: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 2 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Safety InformationThe products described in this manual can fail in a variety of modes due to misuse, age, or malfunction and is notdesigned or intended for used in systems requiring fail-safe performance, including life safety systems. Systemswith the products must be designed to prevent personal injury and property damage during product operationand in the event of product failure.

Warning! Verify power is OFF before connecting or disconnecting the interface or RF cables.

Warranty InformationFreeWave Technologies, Inc. warrants the FreeWave® ZumLink Z9-C or Z9-T (Product) that you have purchasedagainst defects in materials and manufacturing for a period of two years from the date of shipment, depending onmodel number. In the event of a Product failure due to materials or workmanship, FreeWave will, at its discretion,repair or replace the Product. For evaluation of Warranty coverage, return the Product to FreeWave uponreceiving a Return Material Authorization (RMA). The replacement product will remain under warranty for 90days or the remainder of the original product warranty period, whichever is longer.IN NO EVENT WILL FREEWAVE TECHNOLOGIES, INC., ITS SUPPLIERS, OR ITS LICENSORS BE LIABLE FOR ANY DAMAGES ARISINGFROM THE USE OF OR INABILITY TO USE THIS PRODUCT. THIS INCLUDES BUSINESS INTERRUPTION, LOSS OF BUSINESSINFORMATION, INABILITY TO ACCESS OR SEND COMMUNICATION OR DATA, PERSONAL INJURY OR DAMAGE, OR OTHER LOSSWHICH MAY ARISE FROM THE USE OF THIS PRODUCT. THEWARRANTY IS EXCLUSIVE AND ALL OTHER WARRANTIES EXPRESSOR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USEARE EXPRESSLY DISCLAIMED.FreeWave’s Warranty does not apply in the following circumstances:

1. If Product repair, adjustments, or parts replacements are required due to accident, neglect, or unduephysical, electrical, or electromagnetic stress.

2. If Product is used outside of FreeWave specifications as stated in the Product's data sheet.3. If Product has been modified, repaired, or altered by Customer unless FreeWave specifically authorized

such alterations in each instance in writing.

FreeWave Technologies, Inc.5395 Pearl Parkway, Suite 100

Boulder, CO 80301303.381.9200

Toll Free: 1.866.923.6168Fax: 303.786.9948

Copyright © 2018 by FreeWave Technologies, Inc.All rights reserved. www.freewave.com

Page 3: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 3 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Table of Contents

Preface 64. Overview 84.1. CommunicationMethod 85. Included & User-supplied Equipment 95.1. Included Equipment 95.2. User-supplied Equipment 96. Port Connections and Pinout Assignments 106.1. Z9-C or Z9-T Ports and Pinout Connections 116.2. Z9-C or Z9-T Pinout Assignments 127. Installation 147.1. Power Setup 157.2. Installation 158. Firmware Upgrade 168.1. Download the Upgrade File and ZumLink Z9-C and Z9-T Programmer Tool 178.2. Upgrade the Z9-C or Z9-T 229. CLI Configuration 3010. Creating a Basic ZumLink Gateway and Endpoint Network 3311. Approved Antennas 3511.0.1. Omni-Directional Antennas 3511.0.2. Directional Antennas 3511.0.3. Alternative Antennas 36

12. config Parameters 3712.1. factoryDefaults 3812.2. reset 3812.3. restore 3812.4. save 3913. diagPortConfig Parameters 4013.1. cliBaudRate 4113.2. databits 4113.3. diagBaudRate 4113.4. diagMode 4213.5. parity 4213.6. stopbits 4314. fileHandler Parameters 4415. localDiagnostics Parameters 4515.1. signalLevel 46

Page 4: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 4 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

15.2. clearStats 4615.3. noiseLevel 4615.4. RadioAckTx 4715.5. RadioBadAckRx 4715.6. RadioBadCRC 4715.7. RadioBadSync 4815.8. RadioContentionDrop 4815.9. RadioLLRx 4815.10. RadioLLTx 4915.11. RadioNoAckTx 4915.12. RadioReliableRx 4915.13. RadioReliableTx 4915.14. RadioRexmit 5015.15. RadioRx 5015.16. RadioSendingDrop 5015.17. RadioTimedOut 5015.18. RadioTooLong 5015.19. RadioTooShort 5015.20. RadioTx 5116. radioSettings Parameters 5216.1. beaconBurstCount 5316.2. beaconInterval 5416.3. frequencyKey 5516.4. frequencyMasks 5716.5. lnaBypass 5916.6. maxLinkDistanceinMiles 5916.7. networkId 6016.8. nodeId 6016.9. radioFrequency 6116.10. radioMode 6216.11. radioHoppingMode 6316.12. rfDataRate 6516.13. txPower 6717. radioStatus Parameters 6817.1. curPD 6917.2. curRssi 6918. serialPortConfig Parameters 7018.1. cliBaudRate 71

Page 5: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 5 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

18.2. databits 7118.3. flowControl 7218.4. packetizedBaudRate 7218.5. parity 7218.6. passthruBaudRate 7218.7. passthruLatencyMode 7318.8. passthruLatencyTimer 7418.9. stopbits 7419. system Parameters 7519.1. exit 7619.2. filter 7619.3. pages 7619.4. serialMode 7619.5. tags 7720. systemInfo Parameters 7820.1. deviceConfiguration 7920.2. deviceFirmwareVersion 7920.3. deviceModel 7920.4. deviceName 8020.5. deviceSerialNumber 8020.6. FirmwareVersion 8120.7. hopTableVersion 8120.8. layoutHash 8121. Release Notes 8321.1. Version 1.0.7.0 8321.2. Version 1.0.4.0 (Initial Release) 8522. Mechanical Drawing - Z9-C / Z9-T 8623. Hop Tables 8723.1. Standard Hop Set - ZumLink 900MHz Channels 8823.1.1. RF Data Rate: 115.2 kbps 8823.1.2. RF Data Rate: 250 kbps 8923.1.3. RF Data Rate: 500 kbps 8923.1.4. RF Data Rate: 1Mbps 9023.1.5. RF Data Rate: 4Mbps 90

Appendix A: Technical Specifications 91Appendix B: LEDs 94

Normal Operation 94Appendix C: FreeWave Legal Information 95

Page 6: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

Preface

Contact FreeWave Technical SupportFor up-to-date troubleshooting information, check theSupport page at www.freewave.com.FreeWave provides technical support Monday through Friday, 8:00 AM to 5:00 PMMountainTime (GMT -7).

l Call toll-free at 1.866.923.6168.l In Colorado, call 303.381.9200.l Contact us through e-mail at [email protected].

Document StylesThis document uses these styles:

l Parameter setting text appears as: [Page=radioSettings]l File names appear as: configuration.cfg.l File paths appear as:C:\Program Files (x86)\FreeWave Technologies.l User-entered text appears as: xxxxxxxxx.

Caution: Indicates a situation thatMAY cause damage to personnel, .

Example: Provides example information of the related text.

FREEWAVE Recommends: Identifies FreeWave recommendation information.

LUM0075AA Rev Jun-2018 Page 6 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 7: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Preface Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 7 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Important!: Provides crucial information relevant to the text or procedure.

Note: Emphasis of specific information relevant to the text or procedure.

Provides time saving or informative suggestions about using the product.

Warning! Indicates a situation thatWILL cause damage to personnel, .

Page 8: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

4. Overview

Thank you for purchasing the FreeWave Z9-C or Z9-T.ZumLink is the latest generation of radios offered by FreeWave and consists of enclosed andboard level radios.

The Z9-C or Z9-T 900MHzSeries:l Operates in the unlicensed 900MHz ISM band (902-928MHz).l Provides amaximumof 30dBm transmit output power.l Is FCC compliant as both a FrequencyHopping Spread Spectrum (FHSS) and a DigitalModulating (DM) radio.

Note: The frequency hopping capability is available at all bandwidths and the single channel (DM)operation is available for bandwidths of at least 500 kHz.

4.1. Communication MethodZumLink uses Listen Before Talk (LBT) and Carrier SenseMultiple Access (CSMA) where thereare no assigned slots. The radios transmit when the channel is clear.

l TheGateway broadcasts packets to all Endpoints within range.l The Endpoints unicast packets back to the Gateway.l TheGateway acknowledges the Endpoint packets.

FreeWave’s traditional protocol has aGateway Time Slot and a Endpoint Time Slot within aframe.

l TheGateway transmits in its slot and listens in the Endpoint slot.l The Endpoint transmits its slot and listens in the Gateway slot.

LUM0075AA Rev Jun-2018 Page 8 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 9: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

5. Included & User-supplied Equipment

5.1. Included EquipmentIncluded EquipmentQty Description1 Z9-C or Z9-T wireless device.

5.2. User-supplied Equipmentl Z9-C Connection: The Z9-C requires an RS232 serial interface that supports amaximumof 1Mbps over the user data / configuration serial port and 115.2 kbps over theconfiguration / diagnostic serial port.

l Z9-T Connection: The Z9-T requires a TTL serial interface that supports amaximumof 3Mbps over the user data / configuration serial port and 115.2 kbps over the configuration /diagnostic serial port.

l Computer

LUM0075AA Rev Jun-2018 Page 9 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 10: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

6. Port Connections and Pinout Assignments

Port Connectionsl Z9-C or Z9-T Ports and Pinout Connections (on page 11)

Pinout Assignmentsl Z9-C or Z9-T Pinout Assignments (on page 12)

LUM0075AA Rev Jun-2018 Page 10 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 11: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

6. Port Connections and Pinout Assignments Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 11 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

6.1. Z9-C or Z9-T Ports and Pinout Connectionsl The Z9-C or Z9-T shares the same 14-pin interface found on FreeWave'sMM2OEMboardlevel radios easingmigration but is not a drop-in replacement.

l The 14-pin dual row header, location, and pinout are the same as theMM2, MM2-MU,MM2-M13, andGXM series of radios with the exception of pin 2 and pin 6.l Pin 2 is used to place the Z9-C or Z9-T into configurationmode.l Pin 6 is used to reset the Z9-C or Z9-T radio.

Figure 1: Z9-C or Z9-T MMCX RF Connector andPinout with Pin 1 and Pin 14

Page 12: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

6. Port Connections and Pinout Assignments Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 12 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

6.2. Z9-C or Z9-T Pinout Assignments

Figure 2: Z9-C or Z9-T Pinout Assignments

l The Z9-C or Z9-T includes a 14-pin header for power input, data input and output,diagnostics, and configuration.

l The 14-pin header:l is equivalent to the Samtec TMM-107-01-G-D-SM-A.l mateswith SamtecCLT, SQT, SQW, ESQT, TLE, SMM,MMS, and TCSD styleconnectors.

Page 13: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

6. Port Connections and Pinout Assignments Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 13 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Z9-C or Z9-T Pinout Assignments

PinNumber

Name /SignalDescription

RadioInput /Output

Z9-CSignal Level

Z9-TSignal Level Description

1 Power (B+) Input +3 to +5VDC(±10%)

+3 to +5VDC(±10%)

DC Input power

2 Interrupt Input TTL TTL Interrupt is used to place theZ9-C / Z9-T into configurationmode.

Serial Ports (Pins 3 to 10)3 DTR --- (I) Input RS232 TTL Data terminal ready input

4 GND N/A Ground

5 TXD --- (O) Output RS232 TTL Transmit data output

6 Reset Input TTL** TTL** Resets the radio module topower up condition.

7 RXD --- (I) Input RS232 TTL Receive data input

8 CD --- (O) Output RS232 TTL Carrier detect output

9 RTS --- (I) Input RS232 TTL Request to send input

10 CTS --- (O) Output RS232 TTL Clear to send output

Diagnostic Ports (Pins 11 to 13)11 Diag RX Input RS232 TTL Diagnostic Received Data

12 Diag TX Output RS232 TTL Diagnostic Transmitted Data

13 GND N/A Ground

14 NC N/A DoNot Connect

Notesl **A low or ground places the Z9-C or Z9-T into reset.l **A high or floating allows normal Z9-C or Z9-T operation.l FreeWave defines TTL as 0 (zero) to 3.3VDC.l If it's an active-low pin, that pin MUST BE 'pulled' LOW by connecting it to ground (VIL <0.66V).

l For an active high pin, connect it to the HIGH voltage (VIH > 2.64V).

Page 14: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

7. Installation

l Power Setup (on page 15)l Installation (on page 15)

LUM0075AA Rev Jun-2018 Page 14 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 15: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

7. Installation Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 15 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

7.1. Power Setupl The Z9-C or Z9-T is approved to operate with an input voltage range of +3 to +5VDC(±10%) that can supply at least 0.8 Amps.

l See the Technical Specifications (on page 91) for additional information.

FREEWAVE Recommends: All input power supply wires should be at least 20AWGwires.A dedicated and stable power supply line is preferred.The power supply usedMUST providemore current than the amount of current drain listed in thespecifications for the product and voltage. (at least mA at 12V)

Warning! Use electrostatic discharge (ESD) protectors to protect the radio from electric shockand provide filtered conditioned power with over-voltage protection.

7.2. Installation1. Install an FCC-approved antenna.2. Connect the antenna feed line to the ZumLink.

Warning! Only FCC approved antennas may be used. See Approved Antennas (onpage 35).The antennamust be professionally installed on a fixed, mounted, and permanentoutdoor structure to satisfy RF exposure requirements.Any antenna placed outdoors must be properly grounded.Use extreme caution when installing antennas and follow all instructions included withthe antenna.

If installing a directional antenna, preset the antenna’s direction appropriately.

3. Connect the Z9-C or Z9-T to a power supply.The Z9-C or Z9-T is approved to operate with an input voltage range of +3 to +5VDC(±10%) that can supply at least 0.8 Amps.

FREEWAVE Recommends: All input power supply wires should be at least 20AWGwires.A dedicated and stable power supply line is preferred.The power supply usedMUST providemore current than the amount of current drain listed inthe specifications for the product and voltage.

The LED lights blink to show startup.

Note: See LEDs (on page 94) for more information.

4. Continue with:l Firmware Upgrade (on page 16)l CLI Configuration (on page 30)

Page 16: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

8. Firmware Upgrade

Important!: TheDownload proceduremust be completed first.

These are the basic steps to upgrade the Z9-C or Z9-T firmware:A. Download the Upgrade File and ZumLink Z9-C and Z9-T Programmer Tool (on page 17)B. Upgrade the Z9-C or Z9-T (on page 22)

LUM0075AA Rev Jun-2018 Page 16 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 17: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 17 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

8.1. Download the Upgrade File and ZumLink Z9-C and Z9-TProgrammer Tool

Note: The Z9-C and Z9-T use the ZumLink Z9-C and Z9-T Programmer Tool to install the firmwareupgrade file.

Note: The images in this procedure are forWindows® 7 and/or Firefox®.The dialog boxes and windows appear differently on each computer.

1. Click http://support.freewave.com/.The Loginwindow opens.

Important!: Registration is required to use this login.

Figure 3: FreeWave Login window

2. Enter theUser Name andPassword.

3. Click .A successful Loginmessage briefly appears.

Page 18: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 18 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

TheHelp Topicswindow opens.

Figure 4: Help Topics window

4. Click the Firmware link.The Firmwarewindow opens.

Figure 5: Firmware window

5. Click the ZumLink Firmware link.The available firmware/software appears in the window.

Figure 6: ZumLink Firmware window

Page 19: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 19 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

6. Click the firmware/software link.The Firmware Upgradewindow opens.

7. Select and click the attachment.

Figure 7: Z9-C / Z9-T Firmware Upgrade window with selected attachment

Figure 8: ZumLink Z9-C and Z9-T Programmer Tool Firmware Upgradewindow with selected attachment

TheOpening dialog box opens.

Page 20: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 20 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Figure 9: Z9-C / Z9-T Opening dialog box

Figure 10: ZumLink Z9-C and Z9-T Programmer Tool Opening dialog box

8. ClickOK.TheEnter name of file to save to dialog box opens.

Figure 11: Z9-C / Z9-T Enter name of file to save to dialog box

Page 21: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 21 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Figure 12: ZumLink Z9-C and Z9-T Programmer Tool Enter name of file tosave to dialog box

9. Search for and select a location to save the .zip file to and clickSave.TheEnter name of file to save to dialog box closes.

10. Open aWindows® Explorer window and find the location where the .zip file was saved.11. Double-click the .zip file.12. Extract the .fcf and .exe from their respective .zip file into the same location.

Note: The Z9-C / Z9-T .zip file has only the .fcf file used in the upgrade process.

Note: The ZumLink Z9-C and Z9-T Programmer Tool .zip file has only the .exe file used in theupgrade process.

13. Continue with Upgrade the Z9-C or Z9-T (on page 22) procedure.

Page 22: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 22 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

8.2. Upgrade the Z9-C or Z9-TThis procedure describes using drag and drop to upgrade the Z9-C or Z9-T firmware.Notes

l This procedure is for a Z9-C / Z9-T module interfaced to a computer.If interfaced to a device other than a computer, some of these procedure stepsmay not beused.

l The images in this procedure are for Windows® 7 and/or Firefox®.The dialog boxes and windows appear differently on each computer.

l This procedure provides a Tera Term terminal connection to the Z9-C or Z9-T CLI. Otherterminal emulators (e.g., HyperTerminal, PuTTY) may be used.

Procedure1. Verify the Download the Upgrade File and ZumLink Z9-C and Z9-T Programmer Tool (on

page 17) procedure is complete.2. Connect to the Serial Interface of the ZumLink device.

On the Z9-C or Z9-T (Figure 13):l The Z9-C model has an RS232 interface and can be connected directly to an RS232device.l FreeWave offers a cable (FreeWave Part Number: ASC2414DJ) from the radio toa DB9 connector that includes a reset button and power input jack.

l The Z9-T model has a TTL interface and doesNOT work directly with RS232.l If connecting to a device or circuit that is RS232, a circuit is required to adaptbetween the two interfaces.

Page 23: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 23 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Figure 13: Z9-C or Z9-T Connections

3. On the computer connected to the Z9-C or Z9-T, open a terminal program (e.g., TeraTerm).

Note: This procedure provides a Tera Term terminal connection to the Z9-C or Z9-T CLI.Other terminal emulators (e.g., HyperTerminal, PuTTY)may be used.The images in this procedure are forWindows® 7 and/or Firefox®.The dialog boxes and windows appear differently on each computer.

4. In Tera Term, click the Filemenu and selectNew Connection.The Tera Term New Connection dialog box opens.

Figure 14: File menu > New Connection

Page 24: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 24 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

5. Click thePort list box arrow and select the COMport the Z9-C or Z9-T is connected to.

Figure 15: Select the ZumLink COM port

6. ClickOK to save the changes and close the dialog box.The Tera Termwindow shows the connected COMport and Baud rate in the title bar of thewindow.

7. In the Tera Termwindow, click theSetupmenu and selectSerial Port.

Figure 16: Serial menu > Setup Port

The Tera Term: Serial Port Setup dialog box opens.

Note: The image shows the default Z9-C or Z9-T settings.

Page 25: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 25 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Figure 17: Tera Term: Serial Port Setup dialog box with default settings

8. Important: Verify, and change if required, the Tera Term serial port settings (except thePort setting) of the connected Z9-C or Z9-T so the settings are the same as the defaultsshown in Figure 17.

Example: If theBaud Rate is 9600, click the list box arrow and select 115200.

9. ClickOK to save the changes and close the dialog box.

Note: If using the ASC2414DJ cable purchased from FreeWave, push theReset button.Otherwise complete Step 10.

10. On the Z9-C or Z9-T device, momentarily ground the interrupt line (pin 2 on the 14-pinheader).

11. In Tera Term, press <Enter>.The FreeWave Shell returns.

12. Optional: At the > prompt, type systeminfo and press <Enter> to view the currentfirmware version on the Z9-C or Z9-T (Figure 18).

Page 26: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 26 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Figure 18: Existing Firmware Version Installed on the Z9-C / Z9-T

13. At the > prompt, type serialPortConfig.cliBaudRate=230400.14. At the > prompt, type serialPortConfig.flowControl=Off.15. At the > prompt, type save and press <Enter>.16. At the > prompt, type exit and press <Enter>.17. Ground Pin 2 to put the Z9-C or Z9-T into CLI mode.18. Open theMicrosoft®Windows® Device Manager.19. Locate and identify the COMport for the Z9-C or Z9-T.20. Locate the designated folder for the ZumLink Z9-C and Z9-T Programmer Tool .exe file

and double-click the .exe file.

Figure 19: Double-click the .exe File

The ZumLink Z9-C and Z9-T Programmer Tool opens.

Page 27: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 27 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Figure 20: Opened ZumLink Z9-C and Z9-T Programmer Tool

21. Enter the COMport for the Z9-C or Z9-T and press <Enter>.

Figure 21: Opened ZumLink Z9-C and Z9-T Programmer Tool

22. Enter the name of the .fcf file in the designated download folder and press <Enter>.

Figure 22: Opened ZumLink Z9-C and Z9-T Programmer Tool

23. Type 230400 for the baudrate and press <Enter>.

Page 28: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 28 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Figure 23: Initialed Upgrade Process

A successful upgrademessage appears when the upgrade process is complete. (Figure24)

Figure 24: Successful Upgrade Process

24. Optional: Open Tera Term to view the upgraded firmware version on the systeminfo page(Figure 25):

Page 29: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

8. Firmware Upgrade Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 29 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Figure 25: systeminfo page Showing Upgraded Firmware Version

25. Use the CLI Configuration (on page 30) procedure to configure the ZumLink.

Page 30: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

9. CLI Configuration

Important!: A Serial Port on the computer is required for this procedure.

Procedure

Note: The images in this procedure are forWindows® 7 and/or Firefox®.The dialog boxes and windows appear differently on each computer.This procedure provides a Tera Term terminal connection to the Z9-C or Z9-T CLI. Other terminalemulators (e.g., HyperTerminal, PuTTY)may be used.

1. Using theData Interface Connector (see Ports for location):a. Connect to the Serial Interface of the ZumLink device.

l The Z9-C model has an RS232 interface and can be connected directly to anRS232 device.l FreeWave offers a cable (FreeWave Part Number: ASC2414DJ) from the radioto a DB9 connector that includes a reset button and power input jack.

l The Z9-T model has a TTL interface and doesNOT work directly with RS232.l If connecting to a device or circuit that is RS232, a circuit is required to adaptbetween the two interfaces.

b. Apply power to the ZumLink device.2. On the computer connected to the Z9-C or Z9-T, open a terminal program (e.g., Tera

Term).3. In Tera Term, click the Filemenu and selectNew Connection.

LUM0075AA Rev Jun-2018 Page 30 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 31: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

9. CLI Configuration Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 31 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Figure 26: File menu > New Connection

The Tera Term New Connection dialog box opens.4. Click thePort list box arrow and select the COMport the Z9-C or Z9-T is connected to.

Figure 27: Select the ZumLink COM port

5. ClickOK to save the changes and close the dialog box.The Tera Termwindow shows the connected COMport and Baud rate in the title bar of thewindow.

6. In the Tera Termwindow, click theSetupmenu and selectSerial Port.

Figure 28: Serial menu > Setup Port

The Tera Term: Serial Port Setup dialog box opens.

Page 32: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

9. CLI Configuration Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 32 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Figure 29: Tera Term: Serial Port Setup dialog boxwith Default Z9-C or Z9-T Settings

7. Important: Verify, and change if required, the Tera Term serial port settings (except thePort setting) of the connected Z9-C or Z9-T so the settings are the same as the defaultsshown in Figure 29.

Example: If theBaud Rate is 9600, click the list box arrow and select 115200.

8. ClickOK to save the changes and close the dialog box.

Note: If using the ASC2414DJ cable purchased from FreeWave, push theReset button.Otherwise complete Step 9.

9. On the Z9-C or Z9-T device, momentarily ground the interrupt line (pin 2 on the 14-pinheader).

10. In Tera Term, press <Enter>.The FreeWave Shell returns.

Figure 30: FreeWave Shell in Tera Term

11. Continue with Creating a Basic ZumLinkGateway and Endpoint Network (on page 33).

Page 33: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

10. Creating a Basic ZumLinkGateway and Endpoint Network

Note: The basic network described in this procedure is created by accessing the CLI Configuration(on page 30).

1. Connect and apply power to the ZumLink devices in the network.2. Optional: Upgrade the devices using the procedure Upgrade the Z9-C or Z9-T (on page

22).3. Complete the CLI Configuration (on page 30) procedure.4. Select one radio and, at the > prompt, type radioSettings.radioMode=Gateway

and press <Enter>.5. At the > prompt, type a setting between 10 and 30 for the radioSettings.txPower and

press <Enter>.

Example: txPower=30 or radioSettings.txPower=30.

Entering txpower=0 or radiosettings.txpower=0 changes the output power to theminimum or 10 dB.

Note: See radioSettings Parameters (on page 52) for detailed information.

6. For the other radio in the network, at the > prompt, typeradioSettings.radioMode=Endpoint and press <Enter>.

7. Verify the radioSettings.networkId= setting is the same on ALL radios in thenetwork.

LUM0075AA Rev Jun-2018 Page 33 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 34: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

10. Creating a Basic ZumLinkGateway and Endpoint Network Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 34 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Note: For Endpoints, the radioSettings.nodeID is set automatically.

Important!: TheGateway radioSettings.nodeId defaults to 1 and CANNOT be changed.

8. At the > prompt, type save and press <Enter>.A solid green D1 LED indicates that the radios are linked.

Note: See LEDs (on page 94) for additional information.

9. Verify the serialMode (on page 76) parameter is set tosystem.serialMode=Passthru_Data.

Important!: The serialMode settingMUST be set toPassthru_Data for the Z9-C or Z9-T toconnect.

10. Type exit and press <Enter> to exit the FreeWave Shell.

Page 35: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

11. Approved Antennas

11.0.1. Omni-Directional AntennasThe 900MHz is approved by the FCC for use with omni-directional antennaswith a 10.5dBi gainor less.

Note: These antennas, including antenna gains, are approved for use with the ZumLink device.

900MHz Omni-Directional Antennas

Gain (dBd) Gain (dBi) Manufacturer ManufacturerModel Number

FreeWavePart Number

3.85 5.0 Antenex EB8965C EAN0905WC

3.0 5.15 Maxrad MAX-9053 EAN0900WC

-0.15 2.0 Mobile Mark PSKN3-925S EAN0900SR

-2.15 0.0 Mobile Mark PSTG0-915SE EAN0900SQ

11.0.2. Directional AntennasThe 900MHz is approved by the FCC for use with Yagi-directional antennaswith a 16.0 dBi gainor less.

900MHz Directional Antennas

Gain (dBd) Gain (dBi) Manufacturer ManufacturerModel Number

FreeWavePart Number

6.45 8.6 WaveLink PRO890-8-40F02N4 EAN0906YC

LUM0075AA Rev Jun-2018 Page 35 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 36: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

11. Approved Antennas Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 36 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

11.0.3. Alternative AntennasAntennas other than those listed in this section can potentially be used with the ZumLinkwithprovisions.

l The antennasmust be of a similar type.l The antenna gain CANNOT exceed 10.5dBi for Omni-directional.l The antenna gain CANNOT exceed 16.0dBi for Directional antennas.l The overall systemEIRP does not exceed 36dBm.

Warning! A proper combination with the ZumLink is required to ensure the systemmeets FCCrequirements.

Page 37: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

12. config Parameters

l factoryDefaults (on page 38)l reset (on page 38)l restore (on page 38)l save (on page 39)

At the > prompt, type PARAMETER_NAME= and press <Tab> to view other options for thedesignated parameter.

Example: Type diagPortConfig.clibaudrate=press<Tab> to view the options forcliBaudRate (on page 41).

Note: In the CLI, if the "=" sign is appended to the parameter, it is an implied change to thatparameter.If a value is NOT included after the "=", the value becomes a null, space, or 0 (zero) depending onthe parameter.

Example: Entering frequencyKey returns the current value of frequencyKey.Entering frequencyKey= is an implied change to frequencyKey.If a value is NOT included, it changes frequencyKey to 0 (zero).

LUM0075AA Rev Jun-2018 Page 37 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 38: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

12. config Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 38 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

12.1. factoryDefaultsfactoryDefaultsSetting Description

CLI / Web Page [Page=config]

CLI Command config.factoryDefaults=set

Default Setting N/A

Options Set

Description The config.factoryDefaults command restores the Z9-C or Z9-T to its factorydefault configuration.

12.2. resetresetSetting Description

CLI / Web Page [Page=config]

CLI Command config.reset=now

Default Setting N/A

Options N/A

Description The config.reset command resets the Z9-C or Z9-T.

12.3. restorerestoreSetting Description

CLI / Web Page [Page=config]

CLI Command l config.restore=now

l config.restore

l restore

Default Setting N/A

Options N/A

Description The config.restore command reloads a previously saved setting configuration ofthe Z9-C or Z9-T.

Note: Restore happens automatically when the Z9-C or Z9-T starts.

Page 39: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

12. config Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 39 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

12.4. savesaveSetting Description

CLI / Web Page [Page=config]

CLI Command l config.save=now

l config.save

l save

Default Setting N/A

Options N/A

Description The config.save command saves changes made to the Z9-C or Z9-Tconfiguration.

Page 40: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

13. diagPortConfig Parameters

l cliBaudRate (on page 41)l databits (on page 41)l diagBaudRate (on page 41)l diagMode (on page 42)l parity (on page 42)l stopbits (on page 43)

At the > prompt, type PARAMETER_NAME= and press <Tab> to view other options for thedesignated parameter.

Example: Type diagPortConfig.clibaudrate=press<Tab> to view the options forcliBaudRate (on page 41).

Note: In the CLI, if the "=" sign is appended to the parameter, it is an implied change to thatparameter.If a value is NOT included after the "=", the value becomes a null, space, or 0 (zero) depending onthe parameter.

Example: Entering frequencyKey returns the current value of frequencyKey.Entering frequencyKey= is an implied change to frequencyKey.If a value is NOT included, it changes frequencyKey to 0 (zero).

LUM0075AA Rev Jun-2018 Page 40 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 41: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

13. diagPortConfig Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 41 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

13.1. cliBaudRatecliBaudRateSetting Description

CLI / Web Page [Page=diagPortConfig]

CLI Command l diagPortConfig.cliBaudRate=9600

l diagPortConfig.cliBaudRate=19200

l diagPortConfig.cliBaudRate=115200

Default Setting 115200

Options l 9600l 19200l 115200

Description The diagPortConfig.cliBaudRate setting designates the baud rate of thediagnostic port.

13.2. databitsdatabitsSetting Description

CLI / Web Page [Page=diagPortConfig]

CLI Command l diagPortConfig.databits=7

l diagPortConfig.databits=8

Default Setting 8

Options l 7l 8

Description The diagPortConfig.databits setting designates the byte length for thediagnostic port.

13.3. diagBaudRatediagBaudRateSetting Description

CLI / Web Page [Page=diagPortConfig]

CLI Command l diagPortConfig.cliBaudRate=9600

l diagPortConfig.cliBaudRate=19200

l diagPortConfig.cliBaudRate=115200

Page 42: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

13. diagPortConfig Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 42 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

diagBaudRateSetting DescriptionDefault Setting 115200

Options l 9600l 19200l 115200

Description The diagPortConfig.diagBaudRate setting designates the baud rate for thediagnostics port.

13.4. diagModediagModeSetting Description

CLI / Web Page [Page=diagPortConfig]

CLI Command l diagPortConfig.diagMode=CLI

l diagPortConfig.diagMode=Diag

Default Setting Diag

Options l CLIl Diag

Description The diagPortConfig.diagMode setting designates whether the diagnostic port issupporting the command line interface (CLI) or diagnostics.

13.5. parityparitySetting Description

CLI / Web Page [Page=diagPortConfig]

CLI Command l diagPortConfig.parity=None

l diagPortConfig.parity=Even

l diagPortConfig.parity=Odd

Default Setting None

Options l Nonel Evenl Odd

Description The diagPortConfig.parity setting designates the parity for the diagnostic port.

Page 43: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

13. diagPortConfig Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 43 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

13.6. stopbitsstopbitsSetting Description

CLI / Web Page [Page=diagPortConfig]

CLI Command l diagPortConfig.stopbits=1

l diagPortConfig.stopbits=2

Default Setting 1

Options l 1l 2

Description The diagPortConfig.stopbits setting designates the number of stop bits for thediagnostic port.

Page 44: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

14. fileHandler Parameters

Important!: All fileHandler parameters are FreeWave internal use only.

LUM0075AA Rev Jun-2018 Page 44 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 45: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

15. localDiagnostics Parameters

l signalLevel (on page 46)l clearStats (on page 46)l noiseLevel (on page 46)l RadioAckTx (on page 47)l RadioBadAckRx (on page 47)l RadioBadCRC (on page 47)l RadioBadSync (on page 48)l RadioContentionDrop (on page 48)l RadioLLRx (on page 48)l RadioLLTx (on page 49)

l RadioNoAckTx (on page 49)l RadioReliableRx (on page 49)l RadioReliableTx (on page 49)l RadioRexmit (on page 50)l RadioRx (on page 50)l RadioSendingDrop (on page 50)l RadioTimedOut (on page 50)l RadioTooLong (on page 50)l RadioTooShort (on page 50)l RadioTx (on page 51)

LUM0075AA Rev Jun-2018 Page 45 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 46: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

15. localDiagnostics Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 46 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

15.1. signalLevelImportant!: The localDiagnostics are read-only and are dependent upon the connected Z9-C or Z9-T device.

signalLevelSetting Description

CLI / Web Page [Page=localDiagnostics]

CLI Command l localDiagnostics.signalLevel

l signalLevel

Default Setting -128.00

Options N/A

Description The localDiagnostics.signalLevel command reports the Signal Level of theradio in dBm of the last received packet.

Note: This setting shows -128.00 if no packet has been received since thestats were cleared.

15.2. clearStatsImportant!: The localDiagnostics are read-only and are dependent upon the connected Z9-C or Z9-T device.

clearStatsSetting Description

CLI / Web Page [Page=localDiagnostics]

CLI Command l localDiagnostics.clearStats

l clearStats

Default Setting N/A

Options N/A

Description The localDiagnostics.clearStats setting clears diagnostic information.

15.3. noiseLevelImportant!: FreeWave internal use only.

Page 47: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

15. localDiagnostics Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 47 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

15.4. RadioAckTxImportant!: FreeWave internal use only.

15.5. RadioBadAckRxImportant!: The localDiagnostics are read-only and are dependent upon the connected Z9-C or Z9-T device.

RadioBadAckRxSetting Description

CLI / Web Page [Page=localDiagnostics]

CLI Command l localDiagnostics.RadioBadAckRx

l RadioBadAckRx

Default Setting N/A

Options N/A

Description The localDiagnostics.RadioBadAckRx command reports the number ofreceived ACKs missed in unicast transmissions.

15.6. RadioBadCRCImportant!: The localDiagnostics are read-only and are dependent upon the connected Z9-C or Z9-T device.

RadioBadCRCSetting Description

CLI / Web Page [Page=localDiagnostics]

CLI Command l localDiagnostics.RadioBadCRC

l RadioBadCRC

Default Setting N/A

Options N/A

Description The localDiagnostics.RadioBadCRC command reports the number of radiopackets received with data corruption.

Page 48: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

15. localDiagnostics Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 48 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

15.7. RadioBadSyncImportant!: The localDiagnostics are read-only and are dependent upon the connected Z9-C or Z9-T device.

RadioBadSyncSetting Description

CLI / Web Page [Page=localDiagnostics]

CLI Command l localDiagnostics.RadioBadSync

l RadioBadSync

Default Setting N/A

Options N/A

Description The localDiagnostics.RadioBadSync command reports the number of timesbeacons were lost and the Endpoint needed to re-synchronize with the Gatewaywhen radiosettings.radioHoppingMode=Hopping_On.

15.8. RadioContentionDropImportant!: The localDiagnostics are read-only and are dependent upon the connected Z9-C or Z9-T device.

RadioContentionDropSetting Description

CLI / Web Page [Page=localDiagnostics]

CLI Command l localDiagnostics.RadioContentionDrop

l RadioContentionDrop

Default Setting N/A

Options N/A

Description The localDiagnostics.RadioContentionDrop command reports the number oftimes a transmission was backed-off due to contention on the RF channel.

15.9. RadioLLRxImportant!: The localDiagnostics are read-only and are dependent upon the connected Z9-C or Z9-T device.

Page 49: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

15. localDiagnostics Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 49 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

RadioLLRxSetting Description

CLI / Web Page [Page=localDiagnostics]

CLI Command l localDiagnostics.RadioLLRx

l RadioLLRx

Default Setting N/A

Options N/A

Description The localDiagnostics.RadioLLRx command reports the number of packetsreceived over the air without data corruption.

15.10. RadioLLTxImportant!: The localDiagnostics are read-only and are dependent upon the connected Z9-C or Z9-T device.

RadioLLTxSetting Description

CLI / Web Page [Page=localDiagnostics]

CLI Command l localDiagnostics.RadioLLTx

l RadioLLTx

Default Setting N/A

Options N/A

Description The localDiagnostics.RadioLLTx command reports the number of packetstransmitted over the air.

15.11. RadioNoAckTxImportant!: FreeWave internal use only.

15.12. RadioReliableRxImportant!: FreeWave internal use only.

15.13. RadioReliableTxImportant!: FreeWave internal use only.

Page 50: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

15. localDiagnostics Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 50 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

15.14. RadioRexmitImportant!: FreeWave internal use only.

15.15. RadioRxImportant!: The localDiagnostics are read-only and are dependent upon the connected Z9-C or Z9-T device.

RadioRxSetting Description

CLI / Web Page [Page=localDiagnostics]

CLI Command l localDiagnostics.RadioRx

l RadioRx

Default Setting N/A

Options N/A

Description The localDiagnostics.RadioRx command reports the number of data packetscorrectly received over the wireless RF link for this node.

15.16. RadioSendingDropImportant!: FreeWave internal use only.

15.17. RadioTimedOutImportant!: FreeWave internal use only.

15.18. RadioTooLongImportant!: FreeWave internal use only.

15.19. RadioTooShortImportant!: FreeWave internal use only.

Page 51: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

15. localDiagnostics Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 51 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

15.20. RadioTxImportant!: The localDiagnostics are read-only and are dependent upon the connected Z9-C or Z9-T device.

RadioTxSetting Description

CLI / Web Page [Page=localDiagnostics]

CLI Command l localDiagnostics.RadioTx

l RadioTx

Default Setting N/A

Options N/A

Description The localDiagnostics.RadioTx command reports the number of data packetsscheduled to be transmitted.

Page 52: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

16. radioSettings Parameters

l beaconBurstCount (on page 53)l beaconInterval (on page 54)l frequencyKey (on page 55)l frequencyMasks (on page 57)l lnaBypass (on page 59)l maxLinkDistanceinMiles (on page 59)l networkId (on page 60)

l nodeId (on page 60)l radioFrequency (on page 61)l radioHoppingMode (on page 63)l radioMode (on page 62)l rfDataRate (on page 65)l txPower (on page 67)

At the > prompt, type PARAMETER_NAME= and press <Tab> to view other options for thedesignated parameter.

Example: Type diagPortConfig.clibaudrate=press<Tab> to view the options forcliBaudRate (on page 41).

Note: In the CLI, if the "=" sign is appended to the parameter, it is an implied change to thatparameter.If a value is NOT included after the "=", the value becomes a null, space, or 0 (zero) depending onthe parameter.

Example: Entering frequencyKey returns the current value of frequencyKey.Entering frequencyKey= is an implied change to frequencyKey.If a value is NOT included, it changes frequencyKey to 0 (zero).

LUM0075AA Rev Jun-2018 Page 52 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 53: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 53 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

16.1. beaconBurstCountbeaconBurstCountSetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l radioSettings.beaconBurstCount=n

l beaconBurstCount=n

Note: Where n is any number between 1 and 7.

Default Setting 1

Options Any number between 1 and 7.

Description The radioSettings.beaconBurstCount setting designates the number ofconsecutive beacons to send per beaconIntervalBeacon Interval time.Notesl The radioSettings.beaconBurstCount is set on the Gateway device.l The Endpoint radios obtain this value from aGateway with the samenetworkId via the beacon frame.

l This setting is only used whenradiosettings.radioHoppingMode=Hopping_On.

l Increasing the number of beacons may improve RF link reliability in noisyenvironments.

l Decreasing the number of beacons may improve throughput in environmentswhere interference is minimal.

FREEWAVE Recommends: Set the beaconBurstCount (on page 53) to 2or more.This increases the number of beacons sent in a beacon interval.

Page 54: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 54 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

16.2. beaconIntervalbeaconIntervalSetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l radioSettings.beaconInterval=TWENTY_FIVE_MS

l radioSettings.beaconInterval=FIFTY_MS

l radioSettings.beaconInterval=ONE_HUNDRED_MS

l radioSettings.beaconInterval=TWO_HUNDRED_MS

l radioSettings.beaconInterval=FOUR_HUNDRED_MS

Default Setting ONE_HUNDRED_MS

Options l TWENTY_FIVE_MSl FIFTY_MSl ONE_HUNDRED_MSl TWO_HUNDRED_MSl FOUR_HUNDRED_MS

Description The radioSettings.beaconInterval controls how often aGateway radio sends outa beacon packet and changes to the next radio frequency in the hopping pattern.Notesl The radioSettings.beaconInterval is set on the Gateway device.l The Endpoint radios obtain this value from aGateway with the samenetworkId via the beacon frame.

l This setting is only used whenradiosettings.radioHoppingMode=Hopping_On.

l A shorter Beacon Intervalmay improve the RF link reliability in noisyenvironments.

A longer Beacon Intervalmay improve throughput in environmentswhere interference is minimal.

Page 55: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 55 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

16.3. frequencyKeyfrequencyKeySetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l radioSettings.frequencyKey=Key0

l radioSettings.frequencyKey=Key1 to Key16

Default Setting Key0 (zero)

Options l Key0 (zero)l Key1 to Key16

Valid frequencyKey Values

Data Rate of 115.2KFrequency KeyValues Description

0 to 14 Select classic hop tables.

15 Select standard randomized hop table.

16 Select sequential hop table in reverse order of centerfrequencies.

All Other Data RatesFrequency KeyValues Description

0 Select standard randomized hop table.

1 Select sequential hop table in reverse order of centerfrequencies.

Page 56: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 56 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

frequencyKeySetting DescriptionDescription The radioSettings.frequencyKey setting designates the number used as an

index to select a hopping table.Notesl Use a unique Frequency Key setting to use different hop patterns for eachZumLink network.

l This setting is only used whenradiosettings.radioHoppingMode=Hopping_On.l The number of available frequency keys is based on the number of hoppingsequences in the hop table.

l An invalid frequency key setting is determined by:l Being outside of the specified range.

l If an invalid frequency key setting is found, theradioSettings.frequencyKey is NOT changed.

l The frequency key setting being larger than the number of hopping tablesconfigured for a specific rfDataRate.l In this instance, the radioSettings.frequencyKey is set to Key0 (zero).

Important!: The Endpoint radios obtain this value from aGateway with thesame networkId via the beacon frame.After communications are established, any change of this value are pickedup by the Endpoints.

When using different hop patterns on each network, interferencecaused by neighboring ZumLink networks can beminimized.

Page 57: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 57 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

16.4. frequencyMasksfrequencyMasksSetting Description

CLI / Web Page [Page=radioSettings]

CLI Command radioSettings.frequencyMasks=nnnn

Note: Where nnnn is the specified format of the frequency range tomaskshown in:A. Single Channel Format,B. Range of Channels Format, orC. Combination of Channels Format.

Important!: Hop table frequency maskingmasks the channels that fallwithin the range plus or minus one-half (½) the channel bandwidth.

Default Setting Blank

OptionsCaution: ONLY A commaMUST separate the values - NOT acommawith a space.

Use this information in examples A to C:l xxx is a value between 902-927MHz.l yyyy is a value between .0000-.9999MHz.

A. Single Channel Formatl A single entry masks the specified frequency plus the bandwidth on each sideof the center frequency as a function of the rfDataRate.l frequencyMasks=xxx.yyyy,xxx.yyyy,xxx.yyyy

B. Range of Channels Format

Important!: If a radio channel intersects with themask limits, it will bemasked and not used.

l frequencyMasks=xxx.yyyy-xxx.yyyy,xxx.yyyy-xxx.yyyy

C. Combination of Channels Formatl frequencyMasks=xxx.yyyy-xxx.yyyy,xxx.yyyy

Page 58: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 58 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

frequencyMasksSetting DescriptionDescription The radioSettings.frequencyMasks setting designates specific frequencies or a

set of frequencies in the hopping pattern to be removed from usage.

Caution: radioSettings.frequencyMasks entries MUST BE lessthan 128 bytes.ONLY A commaMUST separate the values - NOT a commawith aspace.

Notesl This setting is only used whenradiosettings.radioHoppingMode=Hopping_On.

l All radios in the network MUST use the same value for this setting.l When Frequency Masks is enabled, interference fixed at certain frequencieswithin the spectrum can be avoided by the transmitter.

l Least significant zeros are NOT required.l .9, .09, .009 are valid entries as well as .9000, .0900, .0090.

Type frequencyMasks= and press <Enter> to clear all FrequencyMask entries.

Page 59: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 59 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

16.5. lnaBypasslnaBypassSetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l Enable LNA:l radioSettings.lnaBypass=0

l lnaBypass=0

l Bypass LNA:l radioSettings.lnaBypass=1

l lnaBypass=1

Default Setting 0 (zero)

Options l 0l 1

Description The radioSettings.lnaBypass setting enables the Low Noise Amplifier (LNA)used to boost the radio module receive signal by 10dB.

It can be useful to bypass the LNA if there is a presence of strongsignals in band and packet reception is not good.

16.6. maxLinkDistanceinMilesmaxLinkDistanceinMilesSetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l radioSettings.maxLinkDistanceinMiles=nnn

l maxLinkDistanceinMiles=nnn

Note: Where nnn is themaximum one-way distance (in miles) betweenany nodes in the network.

Default Setting 20miles

Options l Theminimum value is 0miles.l Themaximum value is 120miles.

Description The radioSettings.maxLinkDistanceinMiles setting designates themaximumone-way distance (in miles) between any nodes in the network.

FREEWAVE Recommends: All nodes in the network that communicatewith each other should use the same distance value.

Page 60: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 60 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

16.7. networkIdnetworkIdSetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l radioSettings.networkId=nnnn

l networkId=nnnn

Note: Where nnnn is the network identifier which subdivides traffic onradio units.

Default Setting 43981

Options l Theminimum value is0 (zero).l Themaximum value is 65535.

Description The radioSettings.networkId setting designates the network identifier whichsubdivides traffic on radio units.Notesl Radio units can only communicate with other units that have the sameradioSettings.networkId setting.

Important!: If radios are on the same frequency, they still receive datafrom radios of a different networkId, but the data is dropped.

16.8. nodeIdnodeIdSetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l radioSettings.nodeId=nnnn

l nodeId=nnnn

Note: Where nnnn is a user-designated nodeId instead of the auto-generated nodeId.

Default Setting Predetermined by the Z9-C or Z9-T, this is an auto-generated, unique number from2 through 65533.

Options N/A

Page 61: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 61 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

nodeIdSetting DescriptionDescription The radioSettings.nodeId setting designates the unique ID of the device.

Notesl Each radio with the same networkId must have a UNIQUE nodeId.

l Otherwise 2 or more nodes will unicast an acknowledgement whichmaycollide.

l TheGateway deviceALWAYS has a nodeId of value 1. It cannot bechanged.

16.9. radioFrequencyradioFrequencySetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l radioSettings.radioFrequency=nnn.nnnn

l radioFrequency=nnn.nnnn

Note: Where nnn.nnnn is the operating center frequency.

Default Setting 915.0000 for the Standard Hop Set - ZumLink 900MHz Channels (on page 88)

Options Valid RangesData Rate MHz Range4Mbps 904.5504 - 925.7472

1Mbps 903.0528 - 927.0144

500 kbps 902.7072 - 927.3600

250 kbps 902.5344 - 927.4176

115.2 kbps 902.4768 - 927.5904

Page 62: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 62 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

radioFrequencySetting DescriptionDescription The radioSettings.radioFrequency setting designates the operating center

frequency in MHz.Notesl All radios in the network MUST use the same value for this setting.l This setting is only used whenradiosettings.radioHoppingMode=Hopping_Off.

l The range of this setting is dependent on the rfDataRate (on page 65) setting.l The frequency interval is 100 Hz.l Theminimum value increases and themaximum value decreases as theradioSettings.rfDataRate increases.l The increase in channel bandwidth affects these ranges.

l If the radioSettings.radioFrequency setting is set too close to the band edgefor the current radioSettings.rfDataRate, the radio module rejects the setting.

Important!: A few seconds are needed to apply the change; allow sometime prior to reading back this value.

Read back this value after setting it to determine if it was acceptedby the radiomodule.

16.10. radioModeradioModeSetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l radioSettings.radioMode=Gateway

l radioSettings.radioMode=Endpoint

Default Setting Endpoint

Options l Endpointl Gateway

Page 63: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 63 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

radioModeSetting DescriptionDescription The radioSettings.radioMode setting designates the device type.

Notesl Each network can have only ONE Gateway device.l The remaining devices MUST be configured as Endpoints .l TheGateway deviceALWAYS has a nodeId of value 1. It cannot bechanged.

l The Endpoint or Endpoint-Repeater nodeId values are 2 through 65535.l A Gateway is requiredwhen theradiosettings.radioHoppingMode=Hopping_On.

l A Gateway is NOT requiredwhen theradiosettings.radioHoppingMode=Hopping_Off.

16.11. radioHoppingModeradioHoppingModeSetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l Enable:l radiosettings.radioHoppingMode=Hopping_On

l Disable:l radiosettings.radioHoppingMode=Hopping_Off

Default Setting Hopping_Off

Options l Hopping_Offl Hopping_On

Page 64: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 64 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

radioHoppingModeSetting DescriptionDescription The radioSettings.radioHoppingMode setting enables frequency hopping.

Notesl All radios in the network MUST use the same value for this setting.l For rfDataRate values of 115.2 and 250 kbps, theradioSettings.radioHoppingMode is forcedOn and CANNOT be set toradiosettings.radioHoppingMode=Hopping_Off.

l For rfDataRate values of 500 kbps, 1Mbps, and 4Mbps, the choice of theselected hoppingmode is based on network frequency planning and channelconditions.

l A Gateway is requiredwhen theradiosettings.radioHoppingMode=Hopping_On.

l A Gateway is NOT requiredwhen theradiosettings.radioHoppingMode=Hopping_Off.

Important!: Special rules must be applied for the 115.2 and 250 kbps datarates to enforce regulatory rules.

l If the radioSettings.rfDataRate=RATE_250K:l If the number of hopping channels in the hop table is:

l >=50, themaximum txPower is 30dBm andthe txPower is NOT automatically changed.

l >=25 and <=49, themaximum txPower is 24dBm andthe txPower is automatically reduced to 24dBm.

l <25, all masking is removed.All channels contained in the hop table are re-enabled.txPower is NOT automatically changed.

l If the radioSettings.rfDataRate=RATE_115.2K:l If the number of hopping channels in the hop table is:

l >=50, themaximum txPower is 30dBm andthe txPower is NOT automatically changed.

l <50, all masking is removed.All channels are re-enabled.txPower is NOT automatically changed.

Page 65: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 65 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

16.12. rfDataRaterfDataRateSetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l radioSettings.rfDataRate=RATE_4M

l radioSettings.rfDataRate=RATE_1M

l radioSettings.rfDataRate=RATE_1.5M_BETA_FEATURE

l radioSettings.rfDataRate=RATE_500K

l radioSettings.rfDataRate=RATE_250K

l radioSettings.rfDataRate=RATE_115.2K

Default Setting RATE_1M

Options l RATE_4M (4Mbps mode)l RATE_1M (1Mbps mode)l RATE_1.5M_BETA_FEATURE (1.5Mbps mode)l RATE_500K (500 kbps mode)l RATE_250K (250 kbps mode)l RATE_115.2K (115.2 kbps mode)

Page 66: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 66 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

rfDataRateSetting DescriptionDescription The radioSettings.rfDataRate setting designates the RF link data rate in bits per

second.Notesl All radios in the network MUST use the same value for this setting.l A higher RF link data rate provides more throughput but at the expense of linkdistance or fademargin.

l When changing from lower data rates to higher ones(e.g.,rfDataRate=RATE_115.2K to rfDataRate=RATE_1M), theradioFrequency (on page 61) may be set back to the default if the frequencywould have been out of band.

l When selecting data rates of either rfDataRate=RATE_115.2K orrfDataRate=RATE_250K, radioSettings.radioHoppingMode isautomatically forced to radiosettings.radioHoppingMode=Hopping_On and cannot be turned off.

l For all other data rates, the radioSettings.radioHoppingMode is left to itscurrent setting.

Important!: Special rules must be applied for the 115.2 and 250 kbps datarates to enforce regulatory rules.

l If the radioSettings.rfDataRate=RATE_250K:l If the number of hopping channels in the hop table is:

l >=50, themaximum txPower is 30dBm andthe txPower is NOT automatically changed.

l >=25 and <=49, themaximum txPower is 24dBm andthe txPower is automatically reduced to 24dBm.

l <25, all masking is removed.All channels contained in the hop table are re-enabled.txPower is NOT automatically changed.

l If the radioSettings.rfDataRate=RATE_115.2K:l If the number of hopping channels in the hop table is:

l >=50, themaximum txPower is 30dBm andthe txPower is NOT automatically changed.

l <50, all masking is removed.All channels are re-enabled.txPower is NOT automatically changed.

Caution: The RATE_1.5M_BETA_FEATURE data rate is a Betafeature NOT recommended for production deployment.

Page 67: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

16. radioSettings Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 67 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

16.13. txPowertxPowerSetting Description

CLI / Web Page [Page=radioSettings]

CLI Command l radioSettings.txPower=nn

l txPower=nn

Note: Where nn is the RF output transmit power.

Important!: Entering a decimal value changes the txpower to 0 (zero).

FREEWAVE Recommends: Use whole numbers only.

Default Setting l 30

Options l Themaximum value is 30.

Description The radioSettings.txPower setting designates the RF output transmit power, indB, for the radio.Notesl Output power is limited tomaximum of 30dBm or 1Watt.l Use a higher power to increase link margin.l Use a lower transmit power to reduce interference whenmultiple radio linksare in close proximity.

l Themaximum radioSettings.txPower can be limited if theradiosettings.radioHoppingMode=Hopping_On.l See frequencyMasks (on page 57) for additional details.

Entering txpower=0 or radiosettings.txpower=0 changes theoutput power to theminimum or 10 dB.

Page 68: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

17. radioStatus Parameters

l curPD (on page 69)l curRssi (on page 69)

At the > prompt, type PARAMETER_NAME= and press <Tab> to view other options for thedesignated parameter.

Example: Type diagPortConfig.clibaudrate=press<Tab> to view the options forcliBaudRate (on page 41).

Note: In the CLI, if the "=" sign is appended to the parameter, it is an implied change to thatparameter.If a value is NOT included after the "=", the value becomes a null, space, or 0 (zero) depending onthe parameter.

Example: Entering frequencyKey returns the current value of frequencyKey.Entering frequencyKey= is an implied change to frequencyKey.If a value is NOT included, it changes frequencyKey to 0 (zero).

LUM0075AA Rev Jun-2018 Page 68 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 69: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

17. radioStatus Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 69 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

17.1. curPDImportant!: FreeWave internal use only.

17.2. curRssicurRssiSetting Description

CLI / Web Page [Page=radioStatus]

CLI Command l radioStatus.curRssi

l curRssi

Default Setting N/A

Options N/A

Description The radioStatus.curRssi command reports the value of the current RSSI ONLYwhen there is data being transferred.

Note: This is a Read-only parameter.

Page 70: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

18. serialPortConfig Parameters

l cliBaudRate (on page 71)l databits (on page 71)l flowControl (on page 72)l packetizedBaudRate (on page 72)l parity (on page 72)

l passthruBaudRate (on page 72)l passthruLatencyMode (on page 73)l passthruLatencyTimer (on page 74)l stopbits (on page 74)

At the > prompt, type PARAMETER_NAME= and press <Tab> to view other options for thedesignated parameter.

Example: Type diagPortConfig.clibaudrate=press<Tab> to view the options forcliBaudRate (on page 41).

Note: In the CLI, if the "=" sign is appended to the parameter, it is an implied change to thatparameter.If a value is NOT included after the "=", the value becomes a null, space, or 0 (zero) depending onthe parameter.

Example: Entering frequencyKey returns the current value of frequencyKey.Entering frequencyKey= is an implied change to frequencyKey.If a value is NOT included, it changes frequencyKey to 0 (zero).

LUM0075AA Rev Jun-2018 Page 70 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 71: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

18. serialPortConfig Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 71 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

18.1. cliBaudRatecliBaudRateSetting Description

CLI / Web Page [Page=serialPortConfig]

CLI Command serialPortConfig.cliBaudRate=nnn

Note: Where nnn is the baud rate of the command line interface port.

Default Setting 115200

Options l 9600l 19200l 115200l 230400

l 460800l 921600l 3000000

Description The serialPortConfig.cliBaudRate setting designates the baud rate of thecommand line interface port.Procedure1. Type serialPortConfig.cliBaudRate= using any of the valid options.

Example: serialPortConfig.cliBaudRate=3000000

2. Press <Enter>.

3. Type save and press <Enter> to save the selection.

4. Type reset=now to apply the setting to the serial hardware.

18.2. databitsdatabitsSetting Description

CLI / Web Page [Page=serialPortConfig]

CLI Command l serialPortConfig.databits=7

l serialPortConfig.databits=8

Default Setting 8

Options l 7l 8

Description The serialPortConfig.databits setting designates the number of data bits perbyte for the serial port.

Page 72: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

18. serialPortConfig Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 72 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

18.3. flowControlflowControlSetting Description

CLI / Web Page [Page=serialPortConfig]

CLI Command l serialPortConfig.flowControl=Off

l serialPortConfig.flowControl=Hardware

Default Setting Hardware

Options l Offl Hardware

Description The serialPortConfig.flowControl setting designates the RTS/CTS flow controlof the serial port (not DTR/DSR).

18.4. packetizedBaudRateImportant!: FreeWave internal use only.

18.5. parityparitySetting Description

CLI / Web Page [Page=serialPortConfig]

CLI Command l serialPortConfig.parity=None

l serialPortConfig.parity=Even

l serialPortConfig.parity=Odd

Default Setting None

Options l Nonel Evenl Odd

Description The serialPortConfig.parity setting designates the parity of the serial port.

18.6. passthruBaudRatepassthruBaudRateSetting Description

CLI / Web Page [Page=serialPortConfig]

Page 73: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

18. serialPortConfig Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 73 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

passthruBaudRateSetting DescriptionCLI Command serialPortConfig.passthruBaudRate=n

Note: Where n is the data rate of the serial port.

Default Setting 115200

Options l 9600l 19200l 115200l 230400

l 460800l 921600l 3000000

Description The serialPortConfig.passthruBaudRate setting designates the data rate of theserial port when operating in pass throughmode.

FREEWAVE Recommends: ForALLradioSettings.rfDataRates, use:serialPortConfig.passthruBaudRate=3Mbps.

If 3Mbps CANNOT be used, set theserialPortConfig.passthruBaudRate= to beGREATER THAN theradioSettings.rfDataRate.

18.7. passthruLatencyModepassthruLatencyModeSetting Description

CLI / Web Page [Page=serialPortConfig]

CLI Command l serialPortConfig.passthruLatencyMode=Auto

l Calculated based on the rfDataRate setting.l serialPortConfig.passthruLatencyMode=Manual

l Uses the value set in the serialPortConfig.passthruLatencyTimer=timer.

Default Setting Auto

Options l Autol Manual

Description The serialPortConfig.passthruLatencyMode setting designates whether theLatency Timer is automatically or manually set.

Page 74: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

18. serialPortConfig Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 74 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

18.8. passthruLatencyTimerpassthruLatencyTimerSetting Description

CLI / Web Page [Page=serialPortConfig]

CLI Command serialPortConfig.passthruLatencyTimer=n

Note: Where n is the amount of millisecond time between transmits.

Default Setting 16

Options l Theminimum value is 1.l Themaximum value is 255.

Description The serialPortConfig.passthruLatencyTimer setting designates the amount ofmillisecond time between transmits.Notesl This timer is used to prevent the Serial Input Handler from permanently goingto sleep.

l Normally, when data is available on the Serial Input port, the Handler sets anevent that awakens the Serial Input Handler.

l In the absence of data coming into the Input Serial port, the timer creates anevent that awakens the Serial Input Handler to poll the buffer to insure all datahas been retrieved from the port.

18.9. stopbitsstopbitsSetting Description

CLI / Web Page [Page=serialPortConfig]

CLI Command l serialPortConfig.stopbits=1

l serialPortConfig.stopbits=2

Default Setting 1

Options l 1l 2

Description The serialPortConfig.stopbits setting designates the number of stop bits of theserial port.

Page 75: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

19. system Parameters

l exit (on page 76)l filter (on page 76)

l pages (on page 76)l serialMode (on page 76)l tags (on page 77)

At the > prompt, type PARAMETER_NAME= and press <Tab> to view other options for thedesignated parameter.

Example: Type diagPortConfig.clibaudrate=press<Tab> to view the options forcliBaudRate (on page 41).

Note: In the CLI, if the "=" sign is appended to the parameter, it is an implied change to thatparameter.If a value is NOT included after the "=", the value becomes a null, space, or 0 (zero) depending onthe parameter.

Example: Entering frequencyKey returns the current value of frequencyKey.Entering frequencyKey= is an implied change to frequencyKey.If a value is NOT included, it changes frequencyKey to 0 (zero).

LUM0075AA Rev Jun-2018 Page 75 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 76: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

19. systemParameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 76 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

19.1. exitImportant!: The [Page=system] parameters are only available in the CLI window. See the CLI Configuration (on page 30) procedure for CLI access.

exitSetting Description

CLI / Web Page [Page=system]

CLI Command system.exit=now

Default Setting N/A

Options N/A

Description The system.exit setting is used to exit the CLI mode.

19.2. filterImportant!: FreeWave internal use only.

19.3. pagespagesSetting Description

CLI / Web Page [Page=system]

CLI Command l system.pages

l pages

Default Setting N/A

Options N/A

Description The system.pages command lists all of the pages in the ZumLink.

19.4. serialModeImportant!: The [Page=system] parameters are only available in the CLI window. See the CLI Configuration (on page 30) procedure for CLI access.

Page 77: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

19. systemParameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 77 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

serialModeSetting Description

CLI / Web Page [Page=system]

CLI Command l system.serialMode=Passthru_Data

l The serial port is used for data or configuration but not at the same time.l system.serialMode=CLI

l system.serialMode=Packetized

Default Setting Passthru_Data

Options l CLIl Passthru_Datal Packetized

Description The system.serialMode setting designates the serial port mode.

Important!: The serialMode settingMUST be set toPassthru_Data forthe Z9-C or Z9-T to connect.

19.5. tagsImportant!: FreeWave internal use only.

Page 78: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

20. systemInfo Parameters

l deviceConfiguration (on page 79)l deviceFirmwareVersion (on page 79)l deviceModel (on page 79)l deviceName (on page 80)

l deviceSerialNumber (on page 80)l FirmwareVersion (on page 81)l hopTableVersion (on page 81)l layoutHash (on page 81)

At the > prompt, type PARAMETER_NAME= and press <Tab> to view other options for thedesignated parameter.

Example: Type diagPortConfig.clibaudrate=press<Tab> to view the options forcliBaudRate (on page 41).

Note: In the CLI, if the "=" sign is appended to the parameter, it is an implied change to thatparameter.If a value is NOT included after the "=", the value becomes a null, space, or 0 (zero) depending onthe parameter.

Example: Entering frequencyKey returns the current value of frequencyKey.Entering frequencyKey= is an implied change to frequencyKey.If a value is NOT included, it changes frequencyKey to 0 (zero).

LUM0075AA Rev Jun-2018 Page 78 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 79: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

20. systemInfo Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 79 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

20.1. deviceConfigurationdeviceConfigurationSetting Description

CLI / Web Page [Page=systemInfo]

CLI Command l systemInfo.deviceConfiguration

l deviceConfiguration

Default Setting N/A

Options N/A

Description The systemInfo.deviceConfiguration command reports the device configurationof the Z9-C or Z9-T.

Note: This is a Read-only parameter.

20.2. deviceFirmwareVersiondeviceFirmwareVersionSetting Description

CLI / Web Page [Page=systemInfo]

CLI Command l systemInfo.deviceFirmwareVersion

l deviceFirmwareVersion

Default Setting N/A

Options N/A

Description The systemInfo.deviceFirmwareVersion command reports the device firmwareversion of the Z9-C or Z9-T.

Note: This is a Read-only parameter.

20.3. deviceModeldeviceModelSetting Description

CLI / Web Page [Page=systemInfo]

CLI Command l systemInfo.deviceModel

l deviceModel

Default Setting N/A

Page 80: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

20. systemInfo Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 80 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

deviceModelSetting DescriptionOptions N/A

Description The systemInfo.deviceModel command reports the devicemodel.

Note: This is a Read-only parameter.

20.4. deviceNamedeviceNameSetting Description

CLI / Web Page [Page=systemInfo]

CLI Command l systemInfo.deviceName=nnnn

l deviceName

Note: Where nnnn is the user-defined name for the Z9-C or Z9-T.

Default Setting N/A

Options N/A

Description The systemInfo.deviceName setting designates the user-defined device name.

20.5. deviceSerialNumberdeviceSerialNumberSetting Description

CLI / Web Page [Page=systemInfo]

CLI Command l systemInfo.deviceSerialNumber

l deviceSerialNumber

Default Setting N/A

Options N/A

Description The systemInfo.deviceSerialNumber command reports the device serialnumber.

Note: This is a Read-only parameter.

Page 81: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

20. systemInfo Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 81 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

20.6. FirmwareVersionFirmwareVersionSetting Description

CLI / Web Page [Page=systemInfo]

CLI Command l systemInfo.FirmwareVersion

l FirmwareVersion

Default Setting N/A

Options N/A

Description The systemInfo.FirmwareVersion command reports the firmware version.

Note: This is a Read-only parameter.

20.7. hopTableVersionhopTableVersionSetting Description

CLI / Web Page [Page=systemInfo]

CLI Command l systemInfo.hopTableVersion

l hopTableVersion

Default Setting N/A

Options N/A

Description The systemInfo.hopTableVersion command reports the radio Hop TableVersion of the Z9-C or Z9-T.

Note: This is a Read-only parameter.

20.8. layoutHashlayoutHashSetting Description

CLI / Web Page [Page=systemInfo]

CLI Command l systemInfo.layoutHash

l layoutHash

Default Setting N/A

Options N/A

Page 82: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

20. systemInfo Parameters Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 82 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

layoutHashSetting DescriptionDescription The systemInfo.layoutHash command reports the Unique Layout Identifier.

Note: This is a Read-only parameter.

Page 83: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

21. Release Notes

These sections describe the additions, changes, known limitations, and workarounds in eachsoftware version. Themost recent version is listed first.

The latest software versions and themost recent list of known limitations and workarounds areavailable on www.freewave.com.

21.1. Version 1.0.7.0Release Date: June 2018

Warning! DO NOT remove power from the Z9-C or Z9-T during the firmware upgrade process!If power is removed prematurely during the upgrade process, reinstall the .pkg file andWAITfor the file upgrade process to complete.

Additions and Changesl Hop table frequencymaskingmasks the channels that fall within the range plus or minusone-half (½) the channel bandwidth.

l Improved sensitivity, noise filtering, and interference avoidance for 250 and 500 kbps rates.Throughput rates between theGateway and Endpoint have been rebalanced.

Important!: Data rates 250K and 500K are NOT compatible with previous releases of theZumLink radio firmware.

l Request To Send signal at the serial interface no longer must be active whetherhandshaking is enable or not for the radio to pass data wirelessly.

l FrequencyMasks correction has been implemented.

LUM0075AA Rev Jun-2018 Page 83 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 84: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

21. Release Notes Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 84 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

l The serialMode default is now Passthru_Data (fromPacketized).l This allows the radio to pass data wirelessly.

l LED indication for data reception.l D2 blinks when the radio receives data.

Beta Features

Important!: Beta Features have not been fully tested by FreeWave. The intent is to expose thefeature and receive early feedback from customers.

l 1.5MbpsRF Data Ratel Sensitivity -90dBm

Known Limitations and Workaroundsl Significant data is lost between radios when operating in close proximity (3-6 feet) whenradioSettings.rfDataRate=RATE_4M. (rfDataRate (on page 65)).l Workaround: Reduce power on radios when operating in close proximity.

l Firmware upgrade will stall more than 90% of the time when these settings are in place:l radioSettings.radioMode=Gatewayl serialPortConfig.cliBaudRate=115200

l serialPortConfig.flowControl=Hardware (i.e., On)l Workaround: Increase the cliBaudRate (on page 71).

l On rare occasions, the firmware upgrade reportsSuccess but the firmware did notchange.l Workaround: Re-install the firmware upgrade file.

l SeeUpgrade the Z9-C or Z9-T (on page 22).l The Z9-T radio draws power through the J2-2, J2-3, J2-7, J2-9, and J2-11 lines.

l If the power line (J2-1) is disconnected from the radio and the data lines are using thesame ground as the power line then the power LED (D-15) will be dimly lit.

l Workaround: Disconnect all serial lines and power line.l Power supply instability or fluctuations can cause an infinite reboot cycle in some situations.

l This occurs when the boot process is interrupted.l Workaround: See Power Setup (on page 15).

l If the rfDataRate (on page 65) is set above RATE_115.2K and the user attempts to set thefrequencyKey (on page 55) above Key1, the radio will lose connection to its hop table.l Workaround: The hop table is available when the radioSettings.frequencyKey is setto 0 (zero) or 1 for rfDataRates aboveRATE_115.2K.

l Z9-T-DEVKIT ONLY: The Diag port is not available on the Z9-T-DEVKIT whenflowControl (on page 72) is enabled.

Page 85: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

21. Release Notes Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 85 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

l Workaround: The Diag port is available once the USB is active and the command line isfirst accessed through the USB.

l TheCLI will not error for all invalid input.l The radio will respond withRESULT:0:OK and will either leave the current value inplace or set it to something else.

These parameterswill change the value to something else when invalid input is entered:l frequencyMasks (on page 57)

l Entering too large of range tomaskdoes not send an error.l The value is changed to:ERROR,ERROR,INPUT ERROR,TOO MANY FREQUENCIES MASKED OFF.

l maxLinkDistanceinMiles (on page 59)l Entering a number between -4294967295 and -4294967177 changes the value to anumber between 1 and 119.

l Entering either 150 or 121 changes the value to 120 (themaximumnumber of miles).l txPower (on page 67)

l Entering a decimal value changes the txpower to 0 (zero).

FREEWAVE Recommends: Use whole numbers only.

These parameterswill NOT change the value or error when invalid input is entered:

l diagPortConfig.cliBaudRatel diagPortConfig.databitsl diagPortConfig.diagBaudRatel diagPortConfig.parityl diagPortConfig.stopbitsl radioSettings.beaconIntervall radioSettings.lnaBypassl radioSettings.maxLinkDistanceInMilesl radioSettings.radioHoppingMode

l radioSettings.rfDataRatel serialPortConfig.cliBaudRatel serialPortConfig.databitsl serialPortConfig.flowControll serialPortConfig.packetizedBaudRatel serialPortConfig.parityl serialPortConfig.passthruBaudRatel serialPortConfig.passthruLatencyModel serialPortConfig.stopbits

21.2. Version 1.0.4.0 (Initial Release)Release Date: June 2017Known Limitations and Workarounds

l TheRequest To Send signal at the serial interfacemust be active whether handshaking isenable or not for the radio to pass data wirelessly.

Page 86: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

22. Mechanical Drawing - Z9-C / Z9-T

LUM0075AA Rev Jun-2018 Page 86 of 99 Copyright © 2018 FreeWaveThis document is subject to change without notice. This document is the property of FreeWave Technologies, Inc. and contains proprietary information owned

by FreeWave. This document cannot be reproduced in whole or in part by any means without written permission from FreeWave Technologies, Inc.

22. Mechanical Drawing - Z9-C / Z9-T Z9-C or Z9-T User & ReferenceManual

Page 87: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

23. Hop Tables

l Standard Hop Set - ZumLink 900MHzChannels (on page 88)

LUM0075AA Rev Jun-2018 Page 87 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 88: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

23. Hop Tables Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 88 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

23.1. Standard Hop Set - ZumLink 900MHz ChannelsThese are the standard channels supported when the radioHoppingMode (on page 63) isEnabled.

Note: When theRadio Hopping Mode is Disabled, the frequency can be set manually.

l RF Data Rate: 115.2 kbps (on page 88)l RF Data Rate: 250 kbps (on page 89)l RF Data Rate: 500 kbps (on page 89)

l RF Data Rate: 1Mbps (on page 90)l RF Data Rate: 4Mbps (on page 90)

23.1.1. RF Data Rate: 115.2 kbpsChannel Size (MHz): 0.2304Number of Channels: 110

Standard Hop Set - ZumLink 900MHz Channels

RF Data Rate: 115.2 kbps

Frequency Frequency Frequency Frequency Frequency Frequency

MHz MHz MHz MHz MHz MHz

902.4768 907.0848 911.6928 916.3008 920.9088 925.5168

902.7072 907.3152 911.9232 916.5312 921.1392 925.7472

902.9376 907.5456 912.1536 916.7616 921.3696 925.9776

903.1680 907.7760 912.3840 916.9920 921.6000 926.2080

903.3984 908.0064 912.6144 917.2224 921.8304 926.4384

903.6288 908.2368 912.8448 917.4528 922.0608 926.6688

903.8592 908.4672 913.0752 917.6832 922.2912 926.8992

904.0896 908.6976 913.3056 917.9136 922.5216 927.1296

904.3200 908.9280 913.5360 918.1440 922.7520 927.3600

904.5504 909.1584 913.7664 918.3744 922.9824 927.5904

904.7808 909.3888 913.9968 918.6048 923.2128

905.0112 909.6192 914.2272 918.8352 923.4432

905.2416 909.8496 914.4576 919.0656 923.6736

905.4720 910.0800 914.6880 919.2960 923.9040

905.7024 910.3104 914.9184 919.5264 924.1344

905.9328 910.5408 915.1488 919.7568 924.3648

906.1632 910.7712 915.3792 919.9872 924.5952

906.3936 911.0016 915.6096 920.2176 924.8256

906.6240 911.2320 915.8400 920.4480 925.0560

906.8544 911.4624 916.0704 920.6784 925.2864

Page 89: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

23. Hop Tables Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 89 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

23.1.2. RF Data Rate: 250 kbpsChannel Size (MHz): 0.3456Number of Channels: 73

Standard Hop Set - ZumLink900MHz Channels

RF Data Rate: 250 kbps

Frequency Frequency Frequency Frequency Frequency Frequency

MHz MHz MHz MHz MHz MHz

902.5344 907.0272 911.5200 916.0128 920.5056 924.9984

902.8800 907.3728 911.8656 916.3584 920.8512 925.3440

903.2256 907.7184 912.2112 916.7040 921.1968 925.6896

903.5712 908.0640 912.5568 917.0496 921.5424 926.0352

903.9168 908.4096 912.9024 917.3952 921.8880 926.3808

904.2624 908.7552 913.2480 917.7408 922.2336 926.7264

904.6080 909.1008 913.5936 918.0864 922.5792 927.0720

904.9536 909.4464 913.9392 918.4320 922.9248 927.4176

905.2992 909.7920 914.2848 918.7776 923.2704

905.6448 910.1376 914.6304 919.1232 923.6160

905.9904 910.4832 914.9760 919.4688 923.9616

906.3360 910.8288 915.3216 919.8144 924.3072

906.6816 911.1744 915.6672 920.1600 924.6528

23.1.3. RF Data Rate: 500 kbpsChannel Size (MHz): 0.6912Number of Channels: 36

Standard Hop Set - ZumLink 900MHz ChannelsRF Data Rate: 500 kbpsFrequency Frequency Frequency Frequency Frequency FrequencyMHz MHz MHz MHz MHz MHz902.7072 906.8544 911.0016 915.1488 919.2960 923.4432

903.3984 907.5456 911.6928 915.8400 919.9872 924.1344

904.0896 908.2368 912.3840 916.5312 920.6784 924.8256

904.7808 908.9280 913.0752 917.2224 921.3696 925.5168

905.4720 909.6192 913.7664 917.9136 922.0608 926.2080

906.1632 910.3104 914.4576 918.6048 922.7520 926.8992

Page 90: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

23. Hop Tables Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 90 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

23.1.4. RF Data Rate: 1 MbpsChannel Size (MHz): 1.3824Number of Channels: 18

Standard Hop Set - ZumLink 900MHz Channels

RF Data Rate: 1 Mbps

Frequency Frequency

MHz MHz

903.0528 915.4944

904.4352 916.8768

905.8176 918.2592

907.2000 919.6416

908.5824 921.0240

909.9648 922.4064

911.3472 923.7888

912.7296 925.1712

914.1120 926.5536

23.1.5. RF Data Rate: 4 MbpsChannel Size (MHz): 3.2256Number of Channels: 7

Standard Hop Set - ZumLink 900MHz Channels

RF Data Rate: 4 Mbps

Frequency

MHz

904.5504

907.7760

911.0016

914.2272

917.4528

920.6784

923.9040

Page 91: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

Appendix A: Technical Specifications

Note: Specifications may change at any time without notice. For themost up-to-date specificationsinformation, see the product's data sheet available at www.freewave.com.

Technical SpecificationsSpecification DescriptionTransmitterFrequency Range 902 to 928MHz

Output Power l 10mW to 1Wl User selectable

Range 97 km (60miles), clear line of sight

Channel Spacing l 230.4 kHzl 345.6 kHzl 691.2 kHz

l 1382.4 kHzl 3225.6 kHz

RF Data Rates User selectable

l 115.2 kbpsl 250 kbpsl 500 kbps

l 1Mbpsl 4Mbps

ReceiverIF Selectivity > 40 dB

System Gain 136 dB

LUM0075AA Rev Jun-2018 Page 91 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 92: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Appendix A: Technical Specifications Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 92 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Technical SpecificationsSpecification DescriptionSensitivity 115.2 kbps -105 dBm

250 kbps -102 dBm

500 kbps -99 dBm

1Mbps -95 dBm

4Mbps -83 dBm

Data TransmissionType l Frequency Hopping Spread Spectrum

Modulation l 2 level GFSKl 8-ary FSK

Link Throughput Maximum of 2.2Mbps

Error Detection l 16-bit CRC, 16-bit ARQl Retransmit on error

Hopping Rates User selectable

l 25msl 50msl 100ms

l 200msl 400ms

Hopping Channels l Maximum of 110 channelsl Dependent on the rfDataRate (on page 65) settingl User selectable

Hopping Patterns l Maximum of 16 patternsl Dependent on the rfDataRate (on page 65) settingl User selectable

Protocol Adaptive Spectrum Learning

User Interface Rate l TTL - 3Mbpsl RS232 - 1Mbps

Power RequirementsOperating Voltage +3 to +5VDC (±10%)

Current Consumption Voltage Transmit Receive Idle+3 VDC 843mA 30mA 13mA

+5 VDC 680mA 30mA 13mA

Page 93: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Appendix A: Technical Specifications Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 93 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Technical SpecificationsSpecification DescriptionInterfacesData Connector l 14-pin dual row header for power, data, and diagnostics

l 2mm pin spacingl Either two RS232 or two TTL serial interfaces

Diagnostics Interface Serial, RS232 or TTL

RF Connector MMCX

General InformationOperating Temperature -40°C to +85°C

-40°F to +185°F

Humidity 0 to 95% non-condensing

Dimensions l 50.8 L x 35.56W x 9.65 H (mm)l 2.0 L x 1.4W x 0.38 H (in)

Weight l 15gl 0.03 lb

Reliability 91,328 hour MTBF

Page 94: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Appendix B: LEDs

These are the LEDs for the Z9-C or Z9-T.

Note: See Z9-C or Z9-T Ports and Pinout Connections (on page 11) for additional information.

Normal Operation

LEDs - Normal OperationLED Position Color DescriptionD1 Right Blinking Green Blinking green when RF data transmitting.

D1 Right Blinking Red Blinking red when the RF channel is busy.

D2 Middle Solid Green Solid green when the RF is in receivemode.

D2 Middle Blinking Green Blinking green when the RF is receiving data.

D15 Left (RF side) Solid Green Solid green when the power is On.

D15 Left (RF side) Blinking Red Blinking red when the RF Packet is received and sent out the serial port.

LUM0075AA Rev Jun-2018 Page 94 of 99 Copyright © 2018 FreeWaveThis document is subject to change without notice. This document is the property of FreeWave Technologies, Inc. and contains proprietary information owned

by FreeWave. This document cannot be reproduced in whole or in part by any means without written permission from FreeWave Technologies, Inc.

Z9-C or Z9-T User & ReferenceManual

Page 95: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Z9-C or Z9-TUser & ReferenceManual

Appendix C: FreeWave Legal Information

Export NotificationFreeWave Technologies, Inc. products may be subject to control by the Export Administration Regulations (EAR)and/or the International Traffic in Arms Regulations (ITAR). Export, re-export, or transfer of these products withoutrequired authorization from the U.S. Department of Commerce, Bureau of Industry and Security, or the U.S.Department of State, Directorate of Defense Trade Controls, as applicable, is prohibited. Any party exporting, re-exporting, or transferring FreeWave products is responsible for obtaining all necessary U.S. governmentauthorizations required to ensure compliance with these and other applicable U.S. laws. Consult with your legalcounsel for further guidance.Restricted RightsAny product names mentioned in this manual may be trademarks or registered trademarks of their respectivecompanies and are hereby acknowledged.This manual is only for use by purchasers and other authorized users of FreeWave products.No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical,or for any purpose without the express written permission of FreeWave Technologies, Inc. FreeWave reservesthe right to make changes to this manual without notice. FreeWave assumes no responsibility or liability for theuse of this manual or the infringement of any copyright or other proprietary right. FCC NotificationsThis device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) Thisdevice may not cause harmful interference and 2) this device must accept any interference received, includinginterference that may cause undesired operation.The content of this guide covers FreeWave Technologies, Inc. models sold under FCC ID: KNYPMT0101AB.All models sold under the listed FCC ID(s) must be installed professionally and are only approved for use wheninstalled in devices produced by FreeWave Technologies or third party OEMs with the express written approvalof FreeWave Technologies, Inc. Changes or modifications should not be made to the device.Changes or modifications not expressly approved by the party responsible for compliance could void the user'sauthority to operate the equipment.FCC NEMA Installation and LabelWhere applicable, the models described in this guide must be installed in a NEMA enclosure. When anyFreeWave Technologies, Inc. module is placed inside an enclosure, a label must be placed on the outside of theenclosure. The label must include the text: "Contains Transmitter Module with FCC ID: KNYPMT0101AB."

LUM0075AA Rev Jun-2018 Page 95 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

Page 96: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Appendix C: FreeWave Legal Information Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 96 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

FCC Radiation Exposure StatementThis equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. Thisequipment should be installed and operated with minimum distance 52 cm between the radiator and your body.FCC Notification of Power WarningThe ZumLink Z9-C or Z9-T covered in this document has a maximum transmitted output power of +30dBm.The antennas used MUST provide a separation distance of at least 52 cm from all persons and MUST NOT beco-located or operate in conjunction with any other antenna or transmitter.IC NotificationsThis device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to thefollowing two conditions: (1) this device may not cause interference, and (2) this device must accept anyinterference, including interference that may cause undesired operation of the device.Ce dispositif est conforme aux normes permis-exemptes du Canada RSS d'industrie. L'opération est sujette auxdeux conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence, et (2) ce dispositif doit acceptern'importe quelle interférence, y compris l'interférence qui peut causer le fonctionnement peu désiré du dispositif.The content of this documentation covers FreeWave Technologies, Inc. models sold under IC: 2329B-PMT0101AB.IC Host Installation and LabelWhen any FreeWave Technologies, Inc. module is placed inside a Host, a label must be placed on the outside ofthe Host. The label must include the text “Contains IC: 2329B-PMT0101AB".IC Radiation Exposure StatementThis system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified byHealth Canada Safety Code 6. The system must be installed at a minimum separation distance from the antennato a general bystander of 7.8 inches (20 cm) to maintain compliance with the General Population limits.L’exposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conformeaux limites établies par le Code de sécurité 6 de Santé Canada. Le système doit être installé à une distanceminimale de 7.8 pouces (20 cm) séparant l’antenne d’une personne présente en conformité avec les limitespermises d’exposition du grand public.Mexico IFETELZ9-C Número IFETEL: RCPFRZ917-1310-A1.Z9-T Número IFETEL: RCPFRZ917-1310-A2.La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo odispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquierinterferencia, incluyendo la que pueda causar su operación no deseada.BSD Contiki License NotificationCopyright (c) 2010, Swedish Institute of Computer Science.All rights reserved.Redistribution and use in source and binary forms, with or without modification, are permitted provided that thefollowing conditions are met:

1. Redistributions of source code must retain the above copyright notice, this list of conditions and thefollowing disclaimer.

2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and thefollowing disclaimer in the documentation and/or other materials provided with the distribution.

3. Neither the name of the Institute nor the names of its contributors may be used to endorse or promoteproducts derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE INSTITUTE AND CONTRIBUTORS ``AS IS'' AND ANY EXPRESS ORIMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OFMERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALLTHE INSTITUTE OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,

Page 97: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Appendix C: FreeWave Legal Information Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 97 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OFSUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, ORTORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THISSOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.GNU License NotificationSome of the software in the firmware is licensed under the GNU General Public License and other Open Sourceand Free Software licenses. Contact FreeWave to obtain the corresponding source on CD.UL Power SourceInput power shall be derived from a certified, Class 2:

l single power source orl a limited power source (LPS) in accordance with:l IEC/EN 60950-1l CAN/CSA C22.2 No. 60950-1-07.

l Input voltage for the Z9-C or Z9-T is +3 to +5VDC (±10%).

Standards and Editions

l HazLoc Standardsl ANSI/ISA 12.12.01-2013l ANSI/ISA-12.12.01-2015l CAN/CSA C22.2 No. 213-15l Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2Hazardous (Classified) Locations

l Ordinary Location Standardsl UL 60950, 2nd Editionl CAN/CSA-C22.2 No. 60950, 2nd Editionl IEC 60950, 2nd Editionl EN 60950, 2nd Edition

l Essential Health and Safety Requirements related to the design and construction of products intended foruse in potentially explosive atmospheres given in Annex II to Directive 2014/34/EU of the EuropeanParliament and the Council. Compliance with:l EN 60079-0:2012 + A11:2013l EN 60079-15:2010

l It is hereby declared that the Z9-C or Z9-T described in this document is in compliance with RoHS Directive2011/65/EU of the European Parliament and Council on restriction of the use of certain hazardoussubstances in electrical and electronic appliances.

Schedule of Limitations

l Antenna connection is internal wiring only.l The Ex Components shall only be used in an area of not more than pollution degree 2, as defined inIEC/EN60664-1.

l The Ex Components shall be installed in an enclosure with tool removable door or cover that provides adegree of protection not less than IP 54 in accordance with IEC/EN60679-15.

Page 98: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput

Appendix C: FreeWave Legal Information Z9-C or Z9-TUser & ReferenceManual

LUM0075AA Rev Jun-2018 Page 98 of 99 Copyright © 2018 FreeWave

This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in

part by any means without written permission from FreeWave Technologies, Inc.

l Transient protection shall be provided that is set at a level not exceeding 140% of the peak rated voltagevalue at the supply terminals to the equipment.

l All connectors (J1 to J4) do not have mating connectors with the devices.l The securement of these connectors must be evaluated during end-product investigation.

Page 99: ZumLink™ - FreeWave · 2020. 4. 10. · 2 Interrupt Input TTL TTL Interruptisusedtoplacethe Z9-C/Z9-Tintoconfiguration mode. SerialPorts(Pins3to10) 3 DTR---(I) Input RS232 TTL Dataterminalreadyinput