your preferred lightning & security solutions provider - · pdf file your preferred...

9
www.tokai.com.my Your Preferred Lightning & Security Solutions Provider Electronic Surge Protection (ESP) Product Catalogue

Upload: phungkhue

Post on 06-Feb-2018

228 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Your Preferred Lightning & Security Solutions Provider - · PDF file Your Preferred Lightning & Security ... Electronic Surge Protection (ESP) Product Catalogue. ... Earthing via DIN

www.tokai.com.my

Your Preferred Lightning & SecuritySolutions Provider

Electronic Surge Protection (ESP)Product Catalogue

Page 2: Your Preferred Lightning & Security Solutions Provider - · PDF file Your Preferred Lightning & Security ... Electronic Surge Protection (ESP) Product Catalogue. ... Earthing via DIN

Power Protector - Parallel ConnectionTOKAI ESP

pg 02

InstallationThe protector is installed in parallel as indicated in the diagrams below. The protector should be installed at the load side of the incoming main breakers before any outgoing breaker.

It is recommended to fuse the leads of the protector with MCCB or HRC fuses. Please see product specifications for MCCB or HRC fuse settings.

Power Surge Protector DeviceUse for Main Power Supplies where sensitive or important electrical and electronic equipments are connected.Protects the electrical and electronic equipments from Transient Over-voltage caused by lightning or electrical switching in the Main Power Supplies.Suitable for Tele-communications, Control, Computer, Networking and many other systems.Can be installed in Main Switchboard, Distribution Board and all power distribution systems.Suitable for TN power supply system.Protector for Single Phase Supply 220 / 230 / 240VAC, 40/60Mz.Protector for Three Phase Supply 380 / 400 / 415VAC, 40/60Mz.Uses hybrid circuit protection to achieve both very low let-through voltage and high discharge current.

Maintenance freeParallel Connection allows easy installationSuitable for TN supply system c/w Earth & NeutralSelection of maximum discharge current (Imax) to suit application / Lightning Risk CategoryVery low let-through or claming voltage (Vp)Full mode protection for single phase (L-N, N-E and L-E) and three phase (L1-N, L2-N, L3-N, L1-E, L2-E, L3-E and N-E supplies)Thermal tripping device allows safety disconnect due to faulty suppliesContinuous and repeated protection in intense environmentElectronic indication with Pre-failure warning allows preparation of replacementRemote indication using volt free contact allows easy integration to control or monitoring systemsRobust metallic casing

Product Features

BS6651:1999, Appendix C, Cats C-Low & B-HighIEEE C62.41-1991, Location Cats C1 & B3SS CP33:1996, Appendix FAS 1768-1991, Appendix B, Cat BUL 1449 mains wire-in

IEEE C62.41-1991 Location Cat B3AS 1768-1991, Appendix B, Cat B

Tested to 6kV 1.2/50µs, 3kA 8/20µs, accordance to

Tested to 6kV 0.5µs, 100kHz ring wave, 500A, accordance to

Testing Specifications

L1 L2 L3 N E

L1 L2 L3 N E

L1 L2 L3Status Indicator

NO NC COM

Surge Protection Device

Your Preferred Lightning & Security Solutions Provider

GreenGreen + Red

RedNominal Voltage

Let Through VoltageMax. Discharge Current

Full ProtectionPartial ProtectionDamaged415VAC600V160kA/unit

www.tokai.com.my

Surge Protection Device

Status Indicator

GreenGreen + Red

RedNominal Voltage

Let Through VoltageMax. Discharge Current

Full ProtectionPartial ProtectionDamaged415VAC600V160kA/unit

L N E

NO NC COM

www.tokai.com.my

Your Preferred Lightning & SecuritySolutions Provider

Incoming Supply

L N E

Incoming Supply

Outgoing To Load

Outgoing To Load

Power Protector - Parallel ConnectionTOKAI ESP

pg 03

Product SpecificationsSupply Type

Parallel Model

Nominal Voltage Vn (RMS)

Operational Voltage Vo (RMS)

Operational Frequency

Leakage Current

Clamping or Let-through Voltage Vp

6kV 1.2/50µs, 3kA 8/20µs

Mode of Protection (Full Mode)

Single Phase

TSP 240M1

240V

200-270V

40-60Hz

<200µA

<600V

L-N, L-E, N-E

Three Phase

TSP 415M1

415V

346-470V

40-60 Hz

<200µA

<600V

L1-N, L2-N, L3-N,

L1-E, L2-E, L3-E, N-E

Model No.

Max. Discharge Current (Imax)

8/20µs per mode

Max. Discharge Current (Imax)

8/20µs per phase

Total Max. Discharge Current (Imax)

8/20µs per unit

Other Specifications

Operation Temperature

Conductor Size (mm2)

Weight (kg)

Physical Dimensions (mm)

Remote Control Ratings

Maximum Current

Maximum Voltage

TSP 240M1

40kA

NA

80kA

-40 to 70°C

25

1.0

1A

TSP 240M2

80kA

NA

160kA

-40 to 70°C

25

1.1

1A

TSP 415M1

40kA

80kA

160kA

-40 to 70°C

25

1.6

1A

TSP 415M2

80kA

160kA

320kA

-40 to 70°C

25

1.8

1A

TSP 415M4

120kA

240kA

480kA

-40 to 70°C

25

2.2

1A

Note: The XX denotation represents the maximum discharge current (Imax), see below for complete model number

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

250VAC or 48VDC

Page 3: Your Preferred Lightning & Security Solutions Provider - · PDF file Your Preferred Lightning & Security ... Electronic Surge Protection (ESP) Product Catalogue. ... Earthing via DIN

Power Protector - Low-Current Series ConnectionTOKAI ESP

pg 04

InstallationThe protector is installed in series as indicated in the diagrams below. The protector should be installed as close to the equipment to be protected. Ensure the incoming supply and output to equipment are connected correctly.

It is recommended to fuse the leads of the protector with fused rated in accordance to the unit current rating. The earth is connected at the DIN rail which the unit is installed on.

Power Surge Protector DeviceUse for low current Main Power Supplies where sensitive or important electrical and electronic equipments are connected.Protects the electrical and electronic equipments from Transient Over-voltage caused by lightning or electrical switching in the Main Power Supplies.Suitable for low current systems such as Field Control and Monitoring Panel, Tele-communication equipment and Mobile Electrical & Electronic Equipment.Can be installed in Distribution Panel, Control Panel, Terminal Boxes and Equipment Panels.Protector for Single Phase Supply 220 / 230 / 240VAC, 40/60Mz.Selection of operating current rating, 6, 13 and 20 Amps.Uses hybrid circuit protection to achieve both very low let-through voltage and high discharge current.

Product FeaturesMaintenance freeSeries ConnectionLED status indicationSmall in sizeCan be installed via DIN rail or Screws mounted. (DIN rails is removable for Screw mount)Wide current range to ensure better compatibility to protected equipementsMaximum discharge current of 10kA per mode, 20kA per unitLow let-through or claming voltage (Vp)Full mode protection for single phase (L-N, N-E and L-E) suppliesThermal tripping device allows safety disconnect due to faulty suppliesContinuous and repeated protection in intense environment

Testing Specifications

BS6651:1999, Appendix C, Cats C-Low & B-HighIEEE C62.41-1991, Location Cats C1 & B3SS CP33:1996, Appendix FAS 1768-1991, Appendix B, Cat BUL 1449 mains wire-in

IEEE C62.41-1991 Location Cat B3AS 1768-1991, Appendix B, Cat B

Tested to 6kV 1.2/50µs, 3kA 8/20µs, accordance to

Tested to 6kV 0.5µs, 100kHz ring wave, 500A, accordance to

Series Low Current Protector

www.tokai.com.my

Operational Voltage200 - 270VrmsOperation Frequency50 - 60HzMax. Current6AMax. Discharge Current20kA per unit

STATUS

ELN

EO

UT

LNE

OU

TN

L

LLN

EO

UT

LNE

OU

TN

E

Your Preferred Lightning & SecuritySolutions Provider

Unit is recommended to be fused at rated maximum current or less

Fuse

Fuse

Power Protector - Low-Current Series ConnectionTOKAI ESP

pg 05

Product SpecificationsSupply Type

Parallel Model

Nominal Voltage Vn (RMS)

Operational Voltage Vo (RMS)

Operational Frequency

Maximum Operating Current

Leakage Current

Clamping or Let-through Voltage Vp

6kV 1.2/50µs, 3kA 8/20µs

Mode of Protection (Full Mode)

Single Phase

TPV 240-6A

240V

200-270V

40-60Hz

≤6A

<500µA

<600V

L-N, L-E, N-E

TPV 240-6A

10kA

20kA

-40 to 70°C

2.5

0.3

Single Phase

TPV 240-13A

240V

200-270V

40-60Hz

≤13A

<500µA

<600V

L-N, L-E, N-E

TPV 240-16A

10kA

20kA

-40 to 70°C

2.5

0.35

Single Phase

TPV 240-20A

240V

200-270V

40-60Hz

≤20A

<500µA

<600V

L-N, L-E, N-E

TPV 240-20A

10kA

20kA

-40 to 70°C

2.5

0.4

Model No.

Max. Discharge Current (Imax)

8/20µs per mode

Total Max. Discharge Current (Imax)

8/20µs per unit

Other Specifications

Operation Temperature

Mounting

Conductor Size (mm2)

Weight (kg)

Physical Dimensions (mm)

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

DIN rail according to EN50022 or Screw mount (DIN rail is removable)

Page 4: Your Preferred Lightning & Security Solutions Provider - · PDF file Your Preferred Lightning & Security ... Electronic Surge Protection (ESP) Product Catalogue. ... Earthing via DIN

Closed Circuit Television ProtectorTOKAI ESP

pg 06

InstallationTo begin it is important to ensure that the protector is suitable for the system to be installed based on the voltage, current and bandwidth. The protector is installed in series as indicated in the diagram below. Ensure that the input (wires going away from the equipment) and output (wires going towards the equipment) are connected correctly to ensure protection. Arrange the incoming and outgoing wire correctly to ensure no transient goes back to the system via induction.

When installing for unearth system, remove the metallic screw at the top of the box and replace it with the non-metallic screw provided.

Power Surge Protection DeviceUse for CCTV (Closed Circuit Television) system applicationProtects the CCTV Camera and monitoring system from Transient Over-voltage caused by lightning or electrical switching in the Main Power Supplies.Can be installed in at CCTV camera, CCTV monitoring system control panel, terminal boxes and equipment panels.Suitable for BNC Coaxial Connector both earthed and un-earthed systemUses hybrid circuit protection to achieve both very low let-through voltage and high discharge current.

Product FeaturesMaintenance free.Series Connection.High current limit (300mA) allow usage in wide range of system.Low in line resistance of 1Ω allow easy compatibility to applied system.Changeable configuration from earthed to un-earthed systems.Allow high bandwidth of more than 20Mhz.Metallic enclosure.BNC Coaxial connector allow easy installation and replacement of the protector.DIN rail mounting or panel mount enable easy installation Earthing via DIN Rails permitting easy installationLow let-through or clamping voltage (Vp)Full mode protection (L-Screen, L-Earth and Screen-E)High discharge currentContinuous and repeated protection in intense environment

Testing Speci�cations

BS6651:1999, Appendix C, Cats C-HighITU IX K17 (CCITT)

Tested to 5kV 10/700µs, accordance to

Data Signal Protector

Nominal Voltage - 1V | Maximum Voltage - 6.3VMaximum Current - 300mA | In-Line Resistance - <1Ω

Operating Bandwidth - >20MHz

LINE IN

LIN

E O

UT

CCTV-BNC

www.tokai.com.my

Your Preferred Lightning & Security Solutions Provider

Line

LineIn

LineOut

Line

EarthEarth

System

From Field To Equipment

Screen

Disconnecting screw.To be removed forunearthed system

Data Signal Protector

Nominal Voltage - 1V | Maximum Voltage - 6.3VMaximum Current - 300mA | In-Line Resistance - <1Ω

Operating Bandwidth - >20MHz

LINE IN

LIN

E O

UT

www.tokai.com.my

Your Preferred Lightning & Security Solutions Provider

Line

LineIn

LineOut

Line

EarthEarth

System

From Field To Equipment

Screen

Disconnecting screw.To be removed forunearthed system

From Field To Equipment

Closed Circuit Television ProtectorTOKAI ESP

pg 07

Product SpecificationsModel

Nominal Voltage (Peak to Peak)

Maximum Continuous Operating Voltage

Maximum Load Current

Clamping or Let-through Voltage Vp

5kV 10/700µs, 125A ITU Standard

Nominal In-Line Resistance (per line)

Bandwidth (-3dB, 75Ω system)

Voltage Standing Wave Radio

Leakage Current (Nominal Voltage)

Capacitance

Mode of Protection

TCV BNC

1V

6.3V

300mA

17.5V

More than 20MHz

Less than 1.2

1µA

Less than 30pF

Line to screen, Line to Earth, Screen to Earth

TCV BNC

10kA

-40 to 70°C

DIN rail according to EN50022 or Screw

mount (DIN rail is removable)

BNC Coaxial Female Connector

250

Model No.

Total Max. Discharge Current (Imax)

8/20µs

Other Specifications

Operation Temperature

Mounting

Conductor Size (mm2)

Weight (kg)

Physical Dimensions (mm)

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

Page 5: Your Preferred Lightning & Security Solutions Provider - · PDF file Your Preferred Lightning & Security ... Electronic Surge Protection (ESP) Product Catalogue. ... Earthing via DIN

Power Multi-Plug ProtectorTOKAI ESP

pg 08

InstallationVery easy to use. Just plug the 3-pin plug of the equipment into any of the 3-pin socket provided on the protector.

SelectionThe Power Multi-Plug Protector comes in two version. Standard 3 Gang 3-pin socket and 3 Gang 3-pin socket c/w Telephone Line Protector. Just indicate the model number correctly as below:-

TPV 240MC3 x 3-pin socket

TPV 240MC/TP3 x 3-pin socket with additional Telephone Protector

Product FeaturesMaintenance free.LED status indication.Mounting holes allow easy mounting on the wall, equipment cabinet panel and computer workstations.Can be used for equipments using up to 13A current.Maximum discharge current of 10kA per mode, 20kA per unit.Low let-through or clamping voltage (Vp).Full mode protection (L-N, L-E and N-E).Thermal tripping device and other protection allows safety disconnect due to faulty supplies.Flexible combination of 3 Gang 3-pin sockets or 3 Gang 3-pin sockets with telephone line protection.Continuous and repeated protection in intense environment.Robust metallic casing

Testing Specifications

BS6651:1999, Appendix C, Cat A-HighSS CP33:1996, Appendix F, Cat A-HighUL 1449 mains plug-in

BS6651:1999, Appendix C, Cats C-HighITU IX K17 (CCITT)

BS6651:1999, Appendix C, Cat B-HighSS CP33:1996, Appendix F, B-High

IEEE C62.41-1991 Location Cat A3AS 1768-1991, Appendix B, Cat A

Single Phase Power Multi Plug ProtectorTested to 6kV 1.2/50µs, 3kA 8/20µs accordance to

Tested to 6kV 1.2/50µs, 3kA 8/20µs accordance to

Tested to 6kV 1.2/0.5µs, 100kHz ring wave, 200A accordance to

Telephone Protector (Additional Unit)Tested to 5kV 10/700µs, accordance to

Use for Main Power Supplies for general protection of electrical and electronic equipment and appliances from surge transient.Suitable for all electronics or electrical equipement using 3-pin power plug of up to 13A such as computer desktops, modems, fax machines, printers and server units.Can be installed mounted on the wall and panels within an equipment cabinetProtector for Single Phase Supply 220 / 230 / 240VAC, 40/60Mz.Two versions - Standard 3 gang of 3-pin sockets or with additional telephone RJ11 jack protector

Power Surge Protector Device

Power Multi-Plug Protector

Status

www.tokai.com.my

Power Protector Specifications

Operational Voltage200 - 240Vrms

Operation Frequency50 - 60Hz

Max. Current13A

Max. Discharge Current20kA per unit

Your Preferred Lightning & SecuritySolutions Provider

Power Multi-Plug ProtectorTOKAI ESP

pg 09

Product SpecificationsModel NoNominal Voltage Vn (RMS)Operational Voltage Vo (RMS)Operational FrequencyMaximum Operating Current(unit is fused at 13A)Leakage CurrentClamping or Let-through Voltage Vp

6kV 1.2/50µs, 500A 8/20µs6kV 1.2/50µs, 3kA 8/20µsMode of Protection

Model NoNominal Voltage (D.C.)Nominal Voltage (A.C.)Maximum Continuous Operating VoltageMaximum Load CurrentBandwidth (3dB, 50Ω system)Leakage Current (Nominal Voltage)Modes of ProtectionClamping or Let-through Voltage Vp

5kV 10/700µs, 125A ITU StandardNominal In-Line Resistance (per line)

Model No.Max. Discharge Current (Imax)8/20µs per modeMax. Discharge Current (Imax)8/20µs per phaseOperation TemperatureMountingConnection Type

Weight (kg)Physical Dimensions (mm)

TPV 240MC240V

200-270V40-60Hz≤13A**

<500µA

<560V<600V

L-N, L-E, N-E

TPV 240MC10kA

20kA

-30 to 70°C

Screw mount

Power-3 Square Pin Socket in

accordance to BS1363, MS589, SS145

1.4

TPV 240 MC/TP240V

200-270V40-60Hz≤13A**

<500µA

<560V<600V

L-N, L-E, N-E

TPV 240 MC/TP165V116V185V

500mA>12Mhz

10µAL-L and 2 x L-E

200V4.7Ω

TPV 240 MC/TP10kA

20kA

-30 to 70°C

Screw mount

Power-3 Square Pin Socket in

accordance to BS1363, MS589, SS145

1.5

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

Page 6: Your Preferred Lightning & Security Solutions Provider - · PDF file Your Preferred Lightning & Security ... Electronic Surge Protection (ESP) Product Catalogue. ... Earthing via DIN

Data Signal Protector - Part 1 TOKAI ESP

pg 11

Product SpecificationsModel NoNominal Voltage (D.C.)Nominal Voltage (A.C.)Max. Continuous Operating VoltageMax. Load CurrentClamping or Let-through Voltage Vp

5kV 10/700µs, 125A ITU StandardNominal In-Line Resistance (per line)Bandwidth (3dB, 50Ω system)Leakage Current (Nominal Voltage)Mode of Protection

Model No.Max. Discharge Current (Imax)8/20µs per modeMax. Discharge Current (Imax)8/20µs per unit

Other SpecificationOperation TemperatureConductor Size (mm2)Mounting (Earth Connection)Approximate weight (g) Physical Dimensions (mm)

TDS 066.7V5.0V7.7V

850mA

11V1Ω

1.2MHz200µA

TDS 0610kA

20kA

-30° to 70°C2.5

200

TDS 1616V11V18V

850mA

27V1Ω

12MHz10µA

TDS 1610kA

20kA

-30° to 70°C2.5

200

TDS 3232V22V36V

850mA

46.5V1Ω

12MHz10µA

TDS 3210kA

20kA

-30° to 70°C2.5

200

TDS 5454V38V58V

850mA

72V1Ω

12MHz10µA

TDS 5410kA

20kA

-30° to 70°C2.5

200

TDS TN165V116V185V

320mA

210V4.7Ω

12MHz10µA

TDS TN10kA

20kA

-30° to 70°C2.5

200

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

L-L and 2 x L-E

DIN rail according to EN50022 or Screw Mount (DIN rail is removable)

Data Signal Protector - Part 1TOKAI ESP

pg 10

InstallationTo begin it is important to select the correct protector based on the voltage, current and bandwidth. The protector is installed in seires as indicated in the diagrams below. Ensure that the input (wires going away from the equipment) are connected correctly to ensure protection.

Arrange the incoming and outgoing wire correctly to ensure no transient goes back into the system via induction.

Product FeaturesMaintenance free.Series connection.Wide range of voltage selection including 6V, 16V, 32V, 54V and Telephone Line.High current limit (800mA) allow usage in wide range of system.Low in-line resistance of 1 ohms allow easy compatibility to applied system.Allow high bandwidth of 12Mhz.Metallic enclosure.Pluggable terminal allow easy installation and replacement of the protector.DIN rail mounting or panel allows easy replacement.Earthing via DIN Rails permitting easy installation.Low let-through or clamping voltage (Vp).Full mode protection (L-L and Both L-E).High Discharge Current.

Testing Specifications

BS6651:1999, Appendix C, Cat C-HighITU IX K17 (CCITT)

Tested to 5kV 10/700µs, accordance to

Use for Data Signal and Communication Application.Also applicable to low current DC supply for 800mA and below.Protects sensitive electronics systems and equipments from Surge Transient entering the signal or comm. wires.Suitable for Tele-communication, Field Sensors and Transducer, Control Signal, CCTV, Computer, Networking and other Systems where twisted pair wirings are used.Can be installed in control panel, termination panels and equipment panels.Protectors available for 6V, 16V, 32V, 54V and Telephone Line.Multi-stage protection provide better protection.

Data Signal Protector

From Field To Equipment

3 - L1E

4 - L2

1 - L1E

2 - L2

LINE IN

LIN

E O

UT

TDS

32

TDS 3

2

Data Signal Protector

L1E

L2

L4E

L3

Page 7: Your Preferred Lightning & Security Solutions Provider - · PDF file Your Preferred Lightning & Security ... Electronic Surge Protection (ESP) Product Catalogue. ... Earthing via DIN

Data Signal Protector - Part 2TOKAI ESP

pg 12

InstallationTo begin it is important to select the correct protector based on the voltage, current and bandwidth. The protector is installed in seires as indicated in the diagrams below. Ensure that the input (wires going away from the equipment) are connected correctly to ensure protection.

Arrange the incoming and outgoing wire correctly to ensure no transient goes back into the system via induction.

Product FeaturesMaintenance free.Series connection.Wide range of voltage selection including 6V, 16V, 32V and 54V.High current limit (3A) allow usage in wide range of system.Low in-line resistance of 0.05 ohms allow easy compatibility to applied system.Allow high bandwidth of 120kHz to 180kHz.Metallic enclosure.Pluggable terminal allow easy installation and replacement of the protector.DIN rail mounting or panel allows easy replacement.Earthing via DIN Rails permitting easy installation.Low let-through or clamping voltage (Vp).Full mode protection (L-L and Both L-E).High Discharge Current.Continuous and repeated protection in intense environment

Testing Specifications

BS6651:1999, Appendix C, Cat C-HighITU IX K17 (CCITT)

Tested to 5kV 10/700µs, accordance to

Use for Data Signal and Communication Application.Also applicable to low current DC supply for 3.5A and below.Protects sensitive electronics systems and equipments from Surge Transient entering the signal or comm. wires.Suitable for Tele-communication, Field Sensors and Transducer, Control Signal, CCTV, Computer, Networking and other Systems where twisted pair wirings are used.Can be installed in control panel, termination panels and equipment panels.Protectors available for 6V, 16V, 32V and 54V.Multi-stage protection provide better protection.

Data Signal Protector

From Field To Equipment

3 - L1E

4 - L2

1 - L1E

2 - L2

LINE IN

LIN

E O

UT

TDH

32

TDH

32

Data Signal Protector

L1E

L2

L4E

L3

Data Signal Protector - Part 2 TOKAI ESP

pg 13

Product SpecificationsModel NoNominal Voltage (D.C.)Nominal Voltage (A.C.)Max. Continuous Operating VoltageMax. Load CurrentClamping or Let-through Voltage Vp

5kV 10/700µs, 125A ITU StandardNominal In-Line Resistance (per line)Bandwidth (3dB, 50Ω system)Leakage Current (Nominal Voltage)Mode of Protection

Model No.Max. Discharge Current (Imax)8/20µs per modeMax. Discharge Current (Imax)8/20µs per unit

Other SpecificationOperation TemperatureConductor Size (mm2)Mounting (Earth Connection)Approximate weight (g) Physical Dimensions (mm)

TDH 066.7V5.0V7.7V3.5A

11V0.05Ω120kHz200µA

TDH 0610kA

20kA

-30° to 70°C2.5

200

TDH 1616V11V18V3.5A

27V0.05Ω140kHz10µA

TDH 1610kA

20kA

-30° to 70°C2.5

200

TDH 3232V22V36V3.5A

46.5V0.05Ω150kHz10µA

TDH 3210kA

20kA

-30° to 70°C2.5

200

TDH 5454V38V58V3.5A

72V0.05Ω160kHz10µA

TDH 5410kA

20kA

-30° to 70°C2.5

200

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

L-L and 2 x L-E

DIN rail according to EN50022 or Screw Mount (DIN rail is removable)

Page 8: Your Preferred Lightning & Security Solutions Provider - · PDF file Your Preferred Lightning & Security ... Electronic Surge Protection (ESP) Product Catalogue. ... Earthing via DIN

Network Signal ProtectorTOKAI ESP

pg 14

InstallationTo begin it is important to select the correct protector type based on the different system type (2 twisted pair 4 twisted pair and POE). The protector is installed in series using RJ45 connector type as indicated in the diagrams below. Install the protector near to the equipment that it is protected.

Ensure that the input (wires going away from the equipment) and output (wires going towards the equipment) are connected correctly to ensure protection. Arrange the incoming and outgoing wire correctly to ensure transient does not induce back into the system via induction. Ensure a good earth connection.

Product FeaturesMaintenance free.Series connection.Selection of 2 twisted pair, 4 twisted pair and POE.High current limit.Low in line resistance of 1 ohms allow maintains high signal strength.Low capacitance design.Meets requirement of Cat 3, 4, 5 and 5E.Allow high bandwidth of 100Mhz.Metallic Enclosure.DIN rail mounting or panel mount enable easy installation.Earthing via DIN Rails permitting easy installation.Low let-through or clamping voltage (Vp).Full mode protection (L-L and both L-E).High Discharge Current.Continuous and repeated protection in intense environment.

Testing Specifications

BS6651:1999, Appendix C, Cats C-HighITU IX K17 (CCITT)

Tested to 5kV 10/700µs, Accordance to:

TIA Cat 5 basic link10/100 base TXTIA Cat 5 channelIEEE 802.13.4-UTPIEEE 802.3af

Meets requirement of:

Use to protect Computer Workstation, Network Hub, Servers and Broadband Modems.Protects Internet Network System using RJ45 connector type meeting the requirements of Cat 3, 4, 5 and 5E from Surge Transient.Suitable for all kind of computer network and Ethernet system.Can be installed in Server cabinet, termination panels and equipment panels.Wide range of selection including 2 twisted pairs and 4 twisted pairs network systems, and Power Over Ethernet (POE).Multi-stage protection provide better protection.

Network Signal Protector

Network Signal Protector

LINE IN

LIN

E O

UT

TSP 1

00T-

PO

E

TSP 1

00T-P

OE

Network Signal ProtectorTOKAI ESP

pg 15

Product SpecificationsModel NoNominal Voltage (D.C.)Max. Continuous Operating VoltageMax. Load Current

Clamping or Let-through Voltage Vp

5kV 10/700µs, 125A ITU Standard (L-L)5kV 10/700µs, 125A ITU Standard (L-E)Nominal In-Line Resistance (per line)Bandwidth (3dB, 50Ω system)AttenuationVoltage Standing Wave Ratio (VSWR)Near End Cross Talk (NEXT)Leakage Current (Nominal VoltageProtection Pinning

Model No.Max. Discharge Current (Imax)8/20µs per mode

Other SpecificationOperation TemperatureConductor Size (mm2)Mounting (Earth Connection)

Approximate weight (g) Physical Dimensions (mm)

TSP100T-POE5V — 50V7V — 58V

250mA — 350mA

24V — 72V<400V

1 Ω100MHz

30µA1/2, 3/6 — 4/5, 7/8

TSP100T-POE10kA

-30 to 70°CRJ45 Socket

DIN rail according to EN50022 or Screw mount (DIN rail is removable)

250

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

} Meets requirements ofTIA Cat 5 basic link, 10/100 base TX, TIA Cat 5 channel,

IEEE 802.13.4.UTP and IEEE 802.3af

Page 9: Your Preferred Lightning & Security Solutions Provider - · PDF file Your Preferred Lightning & Security ... Electronic Surge Protection (ESP) Product Catalogue. ... Earthing via DIN

Tokai Engineering (M) Sdn BhdLot 14, Jalan Astaka U8/82,Seksyen U8, Bukit Jelutong,40150 Shah Alam, Selangor Darul Ehsan.Tel: 603-7845 2323 | Fax: 603-7845 5420Email: [email protected]

with a solid track record and portfolio!An Award Winning Company

range of solutions includes:TOKAI’s completeWELD E&LP

www.tokai.com.my

As the nation’s leading lightning protection and security solutions provider, TOKAI is proud to provide quality products and services that protects your homes, buildings, lives and businesses. We are the only ISO certified lightning and security solutions provider in the nation. Our products are registered with Jabatan Kerja Raya and SIRIM. The products also comply to standards BS EN 50164-1, BS 7430, BS EN 50164-2, BS EN 13601. Established in 1993, Tokai has grown from strength to strength, winning numerous projects that have become landmarks in the nation. Tokai is the dominant force in the field of lightning & surge protection as well as engineering security solutions.

Tokai Group of Companies is a 100% Malaysian owned entity. Our engineers and technicians are highly-trained with vast project experience to ensure total customer satisfaction. Tokai's name is synonymous with quality and excellence.

Please visit our website for more details.

Exothermic welding products for permanent connection process.

Earthing and Lightning Protection (E&LP) range of products that are certified to BS EN 50164:2008.

Tokai Integrated Safety, Security and Management to protect people, assets and critical installations.

JabatanPerdana Menteri

Lightning Strike CounterTOKAI ESP

pg 16

InstallationVery easy to use. Mount the counter on top of the copper conductor or aluminium conductor. Mount four screws onto the wall to secure the counter onto the conductor.

Product FeaturesMaintenance free.Digital counter allows easy monitoring.Easy connection.Mounting holes allow easy mounting on the wall.Counter detects discharge current ranging from 300A to 100kA.Uses IP66 Poly Carbonate Box for weather resistance.

Product SpecificationsModel No

Transient Current Range

Counter Display

Lifespan (estimated)

Operation Temperature

Mounting

Weight (kg)

Physical Dimensions (mm)

TSLC2000

300A - 100kA

LCD Screen, 0 - 9999999 counts

5 years

-30° to 70°C

Wall Mount

0.30

80 x 110 x 70

The Tokai Lightning Strike Counter is used for detecting and recording of transient discharge current caused by lightning.It is istalled with the building’s lightning protection system to monitor the amount of lightning strike to the building.With the records of the counter, it will allow for lightning strike record and for maintenance purposes.Can be installed mounted on the wall.

TSLC Series