xtravac vt3000 vacuum tumbler manual plc & parts manual a division of the inauen group ˜ kansas...

26
VT3000 XtraV ac • VT3000 Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ∙ Kansas City, MO USA Tel. 800-728-2999 ∙ Fax 816-472-1999 [email protected]

Upload: doantruc

Post on 01-May-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

VT3000

XtraVac • VT3000Vacuum Tumbler

Operation & Parts Manual

A Division of the Inauen Group ∙ Kansas City, MO USATel. 800-728-2999 ∙ Fax 816-472-1999

[email protected]

Safe Operation Practices General Operation .Read, understand, and follow all instructions in the manual and on the machine before starting.

Keep this manual in a safe place for further and regular reference and for ordering replacement parts.

.Only allow trained personnel familiar with the instructions to operate the machine. Be sure to understand all controls and how to stop the machine quickly. .Do not put your hands near moving parts. .Remove all obstacles, which may interfere with the machine functions. .Clear the work area of items such as electrical wires, gloves, knives, etc. .Be sure that everyone else is clear of your work area before operating the machine. .Do not sit nor stand on the machine. .Be sure turn off the machine after your work is finished. Never leave a running machine

unattended. .Always disconnect and wait until the machine has cooled before doing any maintenance. .Do not wear loose fitting clothes or jewelry as they may get caught in moving parts of the

machine. .Please wear appropriate shoes and clothes to avoid injury caused by moving the machine or

objects falling from the machine. .Never position the machine on an incline more than 30 degrees, it may tip over and hurt

someone seriously.

Your responsibility

This machine should only be operated by personal who can read, understand and respect warnings and instructions regarding this machine in the owners manual.

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Content

Chapter 1:Safety precautions

1.1 Precautions of transportation, installation and packing 1.2 Precautions before and after machine starting Chapter 2:Overall description of the machine 2.1、Features of the machine 2.2、Function of the machine 2.3、Product proper for this machine 2.4、Usage life of the machine 2.5、Specification of the machine

Chapter 3:Function description of the push buttons on the panel & Operation sequence description

Chapter 4:Instructions of operation, maintenance and troubleshooting

4.1、Operation sequence 4.2、Maintenance 4.3、Troubleshooting

Chapter 5:Related environment and accessories of the machine

5.1、Accessory 5.2、Airborne noise level 5.3、Operation environment

Chapter 1:Safety precautions

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

1.1 Precautions of transportation, installation and packing

1.1.1 Preparations before installation

1.1.1.1、Power requirement:

Voltage: Can be set suited to location and needs

Current: 7.7kW

Frequency: 50/60 Hz

Phase: 3ψ

1.1.1.2、Installation requirement:

1.1.1.2.1、Prevent to install the machine in the environment full of dust and corrosive

atmosphere with acid and alkali.

1.1.1.2.2、Prevent to install the machine in the environment with abnormal vibration.

1.1.1.2.3、Prevent to install the machine under direct sunlight or near vapor. Such will affect

its vacuum degree.

1.1.1.2.4、The ground circuit should be independently or parallel.

1.1.1.2.5、Don’t install the machine in the potentially explosive atmosphere

1.1.1.2.6、Installation space includes the requirement of the operator and machine

Length × Width × Height = 2.75 x 3 x 2.75 M

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

1.1.2、Preparations during transportation:

1.1.2.1、The weight of this machine is 780 kg, so that the loading capacity of any handling

device is recommended to be more than 1500 kg. If you are not sure of the safe

loading capacity, please contact the manufacturer for help with such handling

device.

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

1.1.2.2、It’s important to check the balance carefully in advance of moving or placement.

1.1.2.3、The work of lifting or by handling should be carried out by means of qualified

operator.

1.1.2.4、During machine handling and positioning, keep clear of the of the machine.

1.1.2.5、Before handling, be sure that there are no people or barriers obstructing the

machine movement. Clear any object prior to movement.

1.1.3、Machine transportation packaging:

1.1.3.1、Packing material: The base is wood.

1.1.3.2、Packing sequence: Put the wood base on the ground. Then, put the machine on it. Fix

the machine foot with the wood base, pack the machine with plastic film and put

vibration-absorbing board around the machine.

1.2 1.2、Precautions before and after machine starting:

1.2.1、Precautions before machine starting

1.2.1.1、Before using this machine, read and understand the contents of this manual and the

control interface entirely.

1.2.1.2、Check that voltage and power connections are appropriate.

1.2.1.3、Confirm that the electric power and rating is sufficient.

1.2.1.4、Check that all the safety related devices are normal, and that the Vacuum Tumbler is

clear of obstructions.

1.2.1.5、Visual check that all mechanical and electric parts are normal, and check that the

surrounding environment is clean.

1.2.1.6、Power On Sequence:

1.2.1.6.1、Turn on the factory power.

1.2.1.6.2、Turn on the main switch of the machine.

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

1.2.2、Precautions after machine starting:

1.2.2.1、Confirm that the display is correct.

1.2.2.2、Confirm that the sound coming from pump running is normal (refer to clause 3.15.2).

1.2.2.3、Wear safety shoes, protective clothes and mask to ensure safety and hygiene of the

operator.

Chapter 2:Overall description of the machine

2.1、Features of the machine:

2.1.1、The machine main body is made of stainless steel for great endurance and easy

washdown.

2.1.2、The machine uses high-powered vacuum pump (imported from Europe) with

water-resistant design.

2.1.3、The machine is fitted with easily-recalled memory functions and a user-friendly

display.

2.1.4、It is designed for large processing operations & food industry factories.

2.1.5、The machine main body is made of stainless steel, water-proof, heat-proof, easy cleaning,

loading entrance is a specialized design.

2.2、Function of the machine:

2.2.1、Repeat tumbling, mixing product with sauce completely, enhancing the tenderness of

product.

2.2.2、Bulk marination and pickling Automatically, not by manual.

2.3、 Proper products for this machine:

2.3.1、Fresh meat, seafood, agricultural products, prepared food, pickles, and powdery

products …etc.

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

2.4、Usage life of the machine:

2.4.1、Except the consumable parts, the machine’s intended usage life is 10 years.

2.4.2、12 month limited warranty for maintenance, parts, and service after shipping. The date is

calculated from the end of installation.

2.4.3、After the warranty, XtraVac will be happy to assist with any parts or service.

2.4.4、Warranty maintenance service doesn’t include consumable parts and vacuum oil.

2.4.5、If there is any abnormal or unsafe situation during the machine warranty period, please

inform XtraVac. We will respond immediately.

2.5、Specification of the machine:

Model XtraVac VT3000 Machine dimension 2540 X 1650 X 2080 mm Maximum Capacity 2400L Machine Weight 780kg Vacuum Pump 7.5 hp

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Chapter 3:Instructions of PLC System Functions

F1F2F3F4SYS

(Picture 1)

a: Power Switch

b: Emergency Stop (E-STOP)

c. PLC Screen

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

3.1、Turn on the Switch (Pictures 2) and go into this screen. Then touch the Enter will go into

the picture 3.

(Picture 2)

Online at XtraVac.comE-mail: [email protected]

Enter

TEL:+1 800-728-2999 FAX:+1 800-472-1999

XtraVac Packaging Machines F1F2F3F4

SYS

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

3.2、Touch Enter to navigate to this screen (Picture 3)

Tumbling Rate

VacuumHold

OFFOFFOFF

StartVacuumSwitch

IndexScreen

SurveillanceScreen

Abnormal Screen

HZMINMINMIN

# # # #

12341234

SV

PV

Tumbbling Time

AutomaticOperation ScreenStop F1F2F3F4

SYS

# # # # # # . # ## # # #

1234 12.34

Rest Time

(Picture 3)

3.2.1、A- STOP: When the machine stops running, this screen would read Stop.

When the machine starts running, this screen would read ON. B- Operation Screen: This screen indicates each setting’s current value. And the

current running status of the machine.

C- Automatic/Manual: Switch to manual function or Automatic function D- Tumbling Time: The PV is present value, SV is the setting value. Touch the SV

button to bring up the value keypad if the value is to be changed. (unit: min)

E- Resting Time: The PV is present value, SV is the setting value. Touch the SV

button to bring up the value keypad if the value is to be changed. (unit: min)

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

F-Total Time: The PV is presenting value, SV is the setting value. Touch the SV

button to bring up the value keypad if the value is to be changed. (unit: min)

G-Tumbling Rate: The PV is presenting value, SV is the setting value. Touch the SV

button to bring up the value keypad if the value is to be changed. Maximum 60 Hz

H- Switch to Abnormal screen I- Switch to Surveillance screen

J- Switch to Index screen K- Vacuum Switch: When it is OFF, touch to start the vacuum pump.

L- Vacuum Hold: Touch to hold the vacuum pressure of the drum when total time is achieved.

M-Start: When it reads ON, the vacuum tumbler runs automatically. When it reads OFF, the vacuum tumbler runs in semi function.

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

3.3、Touch the Surveillance Screen would enter this screen (Picture 4)

IndexScreen

# # . # #

FrequencySwitching Time

Done

VacuumPressure

Surveillance ScreenStop F1F2F3F4

SYS

BrakeOFF

VacuumHold

PumpOFF

ConverterOFF

Operating

S S

Evacuation Time

# # # #

OperationScreen

AbnormalScreen

(Picture 4)

3.3.1、

A- Stop: When the machine stops running, this screen would read Stop.

When the machine starts running, this screen would read ON.

B- Switch to Surveillance screen

C- Operating: It displays the present progress of vacuum tumbling.

D- Done: After all works are finished, touch it to reset.

E- Vacuum Pressure: When the vacuum pressure is achieved, it will read ON.

F- Brake: When the motor of vacuum tumbler runs, it would read ON.

G- Vacuum Hold: Touch it to hold tha vacuum pressure after the cycle is finished.

It would read ON.

H- Vacuum Pump: When the vacuum pump runs, it will read ON.

I- Converter: It reads ON when Converter is running, and OFF when it is not.

J- Switch to Index screen.

K- Switch to Operation Screen

L- Switch to Abnormal Screen

M- Frequency Switching Time: When the Tumbling time is achieved, it will work.

The vacuum drum will slowly rotate.

N- Evacuation Time: touch it could change the evacuation time.

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

3.4、Touch the Abnormal Screen and will go into this screen (Picture 5)

IndexScreen

OperationScreen

SurveillanceScreen SYS

F4F3F2F1Abnormal Screen

Tumbler Done

Vacuum Motor

(Picture 5)

3.4.1、A-Switch to the Abnormal Screen.

B- Tumbler: If the motor of tumbler is abnormal, it would read abnormal and blink. Then

the machine stops working.

C- Vacuum Motor: If the vacuum pump is abnormal, it would read abnormal and blink.

Then the machine stops working.

D- Done: To solve the machine problems, to touch the Done key to stop the current cycle.

E- Switch to the Index Screen.

F- Switch to the Operation Screen.

G- Switch to Surveillance Screen.

3.4.2、Sequence of trial run:

3.4.2.1、Connect the power. Turn the power switch on.

Caution, remember to ground the machine.

3.4.2.2、It will go into the main screen (Picture 2), switch it into the Operation Screen

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

(Picture 3)

3.4.2.2.1、Trial vacuum pump run: When the Start key (M) is off on the Operation Screen

(Picture 3), touch ON the Vacuum Switch key (K) and the vacuum pump will run.

If the pump sounds smooth, it’s rotating clockwise. If there is abnormal noise, it’s

rotating counterclockwise, turn off the machine immediately. Then, change the

power wires w1、v1. (Page 25-M1)

Precaution: After the trial, turn off the vacuum pump.

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Chapter 4:Instructions of operation, maintenance and troubleshooting

4.1. Operation sequence

4.1.1、Loading sequence: Make sure to connect the power line and ground line properly.

Pump is properly run, and all pipes are connected. Open the Air tightness cover

(Page19-1), Press the Loading button (Page 19-20-1), the rotating speed can be

adjusted by the Tumbling Rate key (G) on the Operation Screen (Picture 3) for

modification.

4.1.2、Running sequence: Touch the Start Key (M) on the Operation Screen (Picture 3), the

vacuum drum starts working, the rotating speed can be adjusted by the Tumbling Rate

Key (G) on the Operation Screen (Picture 3) for modification.

4.1.3、Unloading sequence: After finishing the rotating of the vacuum drum, it will be

evacuated. (The Vacuum Hold key on the Operation Screen (Picture 4) reads ON, the

vacuum pressure on the vacuum drum remains.)

Touch OFF the Start key of the Operation Screen (Picture 3), it will read OFF and will

be in the SEMI function mode. Open the Air tightness Cover (Page 19-1), press the

Unloading button (Page 19-20-2) for the product unloading.

4.1.4、Adjust the rotating speed: Enter to the Operation Screen (Picture 3) and touch the SV

of the Tumbling Rate; it will present the value keypad for choice of the value. It can

increase or reduce the rotating speed when the vacuum drum is rotating.

4.2、Maintenance

4.2.1、Cleaning of the drum: After running, use water to clean inside the drum and wipe with

dry cloth.

4.2.2、Cleaning of the filter: Check the water of the filter if it is filled on schedule. If it is XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

over two-thirds of the amount, pour out the water. Before taking off the filter, please

press the pressure exhaust button (Page19-5-3) first.

4.2.3、Vacuum oil replacement.

4.2.3.1、Recommended vacuum oil: BP Engergol RC100, Esso Nuto H100, Mobil Rarus 427.

4.2.3.2、Drain the previous oil completely before filling new oil

4.2.3.3、Oil capacity should be kept at least two-thirds of total amount.

4.2.4、Change the oil of the vacuum pump for every 300 hours. Also check the oil level from

oil sight glass every week. Oil capacity should be kept at least two-thirds of total

amount. If the oil is dirty, please replace it immediately.

4.2.4、Detail drawing of the oil pump

1. air release hole

2. oil filling hole

3. oil sight glass

4. oil draining hole

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Chapter 5:Related environment and accessories of the machine

5.1、Accessory:

5.1.1、Standard accessory:

5.1.1.1、Vacuum tube:.

5.1.1.2、Sucking tube:

5.2、Noise level:79.4dB(A).

5.3、Storage condition:

5.3.1、Temperature: 0℃~45℃.

5.3.2、Humidity: 20~95%RH.

5.4、Operation environment:

5.4.1、Temperature: 5℃~40℃.

5.4.2、Humidity: 20~95%RH.

5.4.3、Attitude: 0~1000M sea level.

5.4.4、Space requirement:

5.4.4.1、It’s necessary to provide enough space for heat emission, handling and maintenance.

5.4.4.2、The machine should not be installed in a position close to other machines.

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Time parameters of operating the Vacuum Tumblers

Vacuum Tumblers Suggestion

Vacuum Time

Suggestion

Resting Time

Suggestion

Total Time

VT150L~VT600L 10~15 min 3~6 min 1~5 hr

VT1000L~VT3000L 15~20 min 5~10 min 3-10 hr

Note: The above parameters are just for reference, you may use the best suitable times for each product.

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

VT3000

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

No Description No Description

1 Air tightness cover 19 Vacuum Valve 1-1 Sucking entrance valve 20 Product load in/unload controller

1-2 Cover gasket 20-1 Load in button

2 Tub body 20-2 Unload button

3 Base 21 PLC 4 Rotator 22 E-Stop

4-1 Rotator fixing screw 23 Main switch 5 Filter 24 PLC-1

5-1 Entrance 25 PLC-2 5-2 Exit 26 Relay 5-3 Pressure exhaust button 27 Fuse 6 Reduction device motor 28 Terminal block 2 7 Transmission chain 29 Over load relay 8 Back cover 30 Adjusting knob 9 Outer bushing 31 Terminal block 1

9-1 Fixing handle 32 Speed adjusting controller 10 Pressure exhaust valve 33 Vacuum gauge 11 Bushing fixing base 12 Micro switch 13 Cam 14 Gear wheel 15 Bearing 16 Inner bushing

16-1 O ring 16-2 O ring

17 Air exhaust tube 18 Vacuum Pump

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

STAND

ARD

CH

ECKED

PRO

CESSED

NAM

ED

ATEC

IRC

UU

IT DIAG

RAM

PAGE

E D C B A

E D C B A

Converter

Power supply MSC

FF2 1

Vacuum m

otorTum

bler motor

Brae

Exhaust

PLC

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

STAND

ARD

CH

ECKED

PRO

CESSED

NAM

ED

ATEC

IRC

UU

IT DIAG

RAM

PAGE

E D C B A

E D C B A

PU

manual rotating

manual reversal

Abnormal indicator

Tumbler position sw

itch

Motor broken

Reach of prossure

Slow

Com

mon point

Rototing

Reversal

Slow

Vacuum m

otor

Broke

Exhanst valve

manu / Auto

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

STAND

ARD

CH

ECKED

PRO

CESSED

NAM

ED

ATEC

IRC

UU

IT DIAG

RAM

PAGE

E D C B A

E D C B A

3~ MRST

L1L2L3W V U

T3 T2 T1

RARBRC

FWD

REV

DCM

M11

VFD

-BRS-485 Series m

essage

Rotating

Reversal

Slow

Com

mon point

ConverterAbnorm

al indicator

Motor

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

STAND

ARD

CH

ECKED

PRO

CESSED

NAM

ED

ATEC

IRC

UU

IT DIAG

RAM

PAGE

E D C B A

E D C B A

56-7-340 19

Power base

Vacuum m

otor

Vacuum

pressure sw

itch

XtraVac Packaging Machines VT3000 Vacuum Tumbler

419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]