wgf rk2
TRANSCRIPT
![Page 1: WGF RK2](https://reader038.vdocuments.mx/reader038/viewer/2022100514/577ce4051a28abf1038d8767/html5/thumbnails/1.jpg)
7/30/2019 WGF RK2
http://slidepdf.com/reader/full/wgf-rk2 1/9
Equipment Type:
Document Description:
Equipment Code:
Technical Characteristic:
Criticality:
Rate:
Material:
Other Information
Equipment Component Cause of Failure Inspection Control Inspection T
Waste gas fan Motor Safety Lighting 4 Senses First level
Safety House keeping 4 Senses First level
Safety Guards 4 Senses First level
Motors integrity and fixations 4 Senses First level
Motors Cable damage / gland failure / poor cabling 4 Senses First level
Motors Loose mountings and fixations 4 Senses First level
Motors Poor House keeping 4 Senses First level
Motors Bearing failure / gearbox teeth failure 4 Senses First level
Motors Over heating / overloading / Hot environment 4 Senses First level
Motors Bearing failure / gearbox teeth failure 4 Senses First level
Motors looseness / overheating / Broken connections 4 Senses First level
Motors Winding failure / insulation failure / dirty windings Meggering and Polarisa Specific
VSD Drive Panel integrity and fixations 4 Senses First level
VSD Drive Dirty, Choked Panel filters 4 Senses First level
VSD Drive Fan bearings and fins for build ups 4 Senses First level
VSD Drive Airconditioning / house keeping / 4 Senses First level
VSD Drive Capacitors shrting & degradation / leakage / IGBT's Degradation Measure IGBT's Specific
VSD Drive Capacitors shrting & degradation / leakage / IGBT's Degradation Measure IGBT', Diodes Specific
VSD Drive Cards damage,humidity, dust and accumulation 4 Senses First level
![Page 2: WGF RK2](https://reader038.vdocuments.mx/reader038/viewer/2022100514/577ce4051a28abf1038d8767/html5/thumbnails/2.jpg)
7/30/2019 WGF RK2
http://slidepdf.com/reader/full/wgf-rk2 2/9
Equipment Type:
Document Description:
Equipment Code:
Technical Characteristic:
Criticality:
Rate:
Material:
Other Information
IJP Code IJP Description Equipment Component Cause of Failure
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection Safety House keeping House keeping FNIFRE140 Electrical Firstlevel 1 Week Running Inspection Safety Lighting Lighting
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection Safety Guards Guards
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection WGF RK2 Motors integrity and fixations
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection WGF RK2 Motors Cable damage / gland failure / po
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection WGF RK2 Motors Loose mountings and fixations
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection WGF RK2 Motors Poor House keeping
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection WGF RK2 Motors Bearing failure / gearbox teeth fa
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection WGF RK2 Motors Over heating / overloading / Hot e
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection WGF RK2 Motors Bearing failure / gearbox teeth fa
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection WGF RK2 VSD Drive Panel integrity and fixations
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection WGF RK2 VSD Drive Dirty, Choked Panel filters
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection WGF RK2 VSD Drive Airconditioning / house keeping /
FNISSE420 Electrical Specific 26 Week Stop Inspection WGF RK2 Motors looseness / overheating / Broken
FNISSE420 Electrical Specific 26 Week Stop Inspection WGF RK2 Motors Winding failure / insulation failure
FNISSE430 Electrical Specific 26 Week Stop Inspection WGF RK2 VSD Drive Fan bearings and fins for build upFNISSE430 Electrical Specific 26 Week Stop Inspection WGF RK2 VSD Drive Cards damage,humidity, dust and
FNISSE430 Electrical Specific 26 Week Stop Inspection WGF RK2 VSD Drive Inverters Capacitors shorting & d
FNISSE430 Electrical Specific 26 Week Stop Inspection WGF RK2 VSD Drive DSU Capacitors shorting & degra
![Page 3: WGF RK2](https://reader038.vdocuments.mx/reader038/viewer/2022100514/577ce4051a28abf1038d8767/html5/thumbnails/3.jpg)
7/30/2019 WGF RK2
http://slidepdf.com/reader/full/wgf-rk2 3/9
frequency Inspectio Responsibility
1 Week Running Inspector - E1 Week Running Inspector - E
1 Week Running Inspector - E
1 Week Running Inspector - E
1 Week Running Inspector - E
1 Week Running Inspector - E
1 Week Running Inspector - E
1 Week Running Inspector - E
1 Week Running Inspector - E
1 Week Running Inspector - E
1 Week Running Inspector - E
1 Week Running Inspector - E
1 Week Running Inspector - E
26 weeks Stop Inspector - E
26 weeks Stop Inspector - E
26 weeks Stop Inspector - E26 weeks Stop Inspector - E
26 weeks Stop Inspector - E
26 weeks Stop Inspector - E
![Page 4: WGF RK2](https://reader038.vdocuments.mx/reader038/viewer/2022100514/577ce4051a28abf1038d8767/html5/thumbnails/4.jpg)
7/30/2019 WGF RK2
http://slidepdf.com/reader/full/wgf-rk2 4/9
Equipment Type:
Document Description:
Equipment Code:
Technical Characteristic:
Criticality:
Rate:
Material:
Other Information
IJP Code IJP Description Component
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection
FNISSE420 Electrical Specific 26 Week Stop Inspection
FNISSE430 Electrical Specific 26 Week Stop Inspection
3 Inspections
![Page 5: WGF RK2](https://reader038.vdocuments.mx/reader038/viewer/2022100514/577ce4051a28abf1038d8767/html5/thumbnails/5.jpg)
7/30/2019 WGF RK2
http://slidepdf.com/reader/full/wgf-rk2 5/9
Cause of Failure Inspection CoInspection Type Inspection Mode Frequency Responsibility
![Page 6: WGF RK2](https://reader038.vdocuments.mx/reader038/viewer/2022100514/577ce4051a28abf1038d8767/html5/thumbnails/6.jpg)
7/30/2019 WGF RK2
http://slidepdf.com/reader/full/wgf-rk2 6/9
Equipment Type:
Document Description:
Equipment Code:
Technical Characteristic:
Criticality:
Rate:
Material:
Other Information
IJP Code IJP Description Equipment Component Cause of Failure Ins
FNIFRE140 Electrical Firstlevel 1 Week Running InspectionFNISSE420 Electrical Specific 26 Week Stop Inspection
FNISSE430 Electrical Specific 26 Week Stop Inspection
![Page 7: WGF RK2](https://reader038.vdocuments.mx/reader038/viewer/2022100514/577ce4051a28abf1038d8767/html5/thumbnails/7.jpg)
7/30/2019 WGF RK2
http://slidepdf.com/reader/full/wgf-rk2 7/9
Freq St Act IJP Code IJP Code Description1 Week R INF/E FNIFRE140 Electrical Firstlevel 1 Week Running Inspection
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection
FNIFRE140 Electrical Firstlevel 1 Week Running InspectionFNIFRE140 Electrical Firstlevel 1 Week Running Inspection
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection
FNIFRE140 Electrical Firstlevel 1 Week Running Inspection
FNIFRE140 Electrical Firstlevel 1 Week Running InspectionFNIFRE140 Electrical Firstlevel 1 Week Running Inspection
26 Week S INS/E FNISSE420 Electrical Specific 26 Week Stop Inspection
FNISSE420 Electrical Specific 26 Week Stop Inspection
26 Week S INS/E FNISSE430 Electrical Specific 26 Week Stop Inspection
FNISSE430 Electrical Specific 26 Week Stop Inspection
FNISSE430 Electrical Specific 26 Week Stop Inspection
FNISSE430 Electrical Specific 26 Week Stop Inspection
![Page 8: WGF RK2](https://reader038.vdocuments.mx/reader038/viewer/2022100514/577ce4051a28abf1038d8767/html5/thumbnails/8.jpg)
7/30/2019 WGF RK2
http://slidepdf.com/reader/full/wgf-rk2 8/9
ComponentLighting
House keeping
Guards
Motors
Motors
Motors
MotorsMotors
Motors
VSD Drive
VSD DriveVSD Drive
Motors
Motors
VSD Drive
VSD Drive
VSD Drive
VSD Drive
![Page 9: WGF RK2](https://reader038.vdocuments.mx/reader038/viewer/2022100514/577ce4051a28abf1038d8767/html5/thumbnails/9.jpg)
7/30/2019 WGF RK2
http://slidepdf.com/reader/full/wgf-rk2 9/9
IJP Content10.Check lighting in the area if sufficient.
20.Check General house keeping and spillages
30.Check guards integrity and equipment guards are in position
40.Check motor integrity and fixations
50.Check Cable, gland for damage.
60. Cjheck for Loose mountings and fixations
70. Check motor House keeping80.Feel for abnormal vibrations
80.Feel for abnormal Temperature
90.Check Panel integrity and fixations
100. check panel filters if Dirty and Choked Panel filters110. Check Airconditioning.
10.looseness / overheating / Broken connections
20.Winding failure / insulation failure / dirty windings
10.Fan bearings and fins for build ups
20.Cards damage,humidity, dust and accumulation
30.Check and measure Inverters Capacitors shorting,degradation,leakage & IGBT's Degradation
40.Check and measure DSU Capacitors shorting,degradation,leakage & IGBT's Degradation