we provide position feedback and sensors for …€¦ · nec class i division 1 groups abcd t5/t6...

1
NEC Class I Division 1 Groups ABCD T5/T6 Class II Division 1 Groups EFG T5/T6 Class III Enclosure Type 4X/6P Ambient Temperature Range: –40...+65 °C (T6) or –40...+80 °C (T5) 10 14 10 11 12 13 10 11 12 13 Marking according to NEC 500 (US)/CEC Annex J (CA) Equipment Group Equipment Category Gas (/= marking of a device with two categories) Equipment Category Dust Ex for Electrical Apparatus Type of Protection Explosion Group Gas Explosion Group Dust Temperature Class (Gas) Max. Surface Temperature (Dust) EPL-Equipment Protection Level IP-Code Max. Ambient Temperature 6a 1 2a 3 4 5a 6b 2b 7 8 9 5b ATEX IECEx Marking according to EU directive 2014/34/EU (ATEX) Marking according to EN 60079 and IEC 60079 Equipment Group Definition I Equipment group I applies to equipment intended for use in underground parts of mines, and to those parts of surface installations of such mines, liable to be endangered by firedamp and/or combustible dust. II Equipment group II applies to equipment intended for use in other places liable to be endangered by explosive atmospheres. Zone Definition Zone 0 A place in which a hazardous explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is present continuously or for long periods or frequently. Zone 1 A place in which an explosive atmosphere consisting of a mixture of air with flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally. Zone 2 A place in which an explosive atmosphere consisting of a mixture of air with flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. Zone 20 A place in which an explosive atmosphere in the form of a cloud of combustable dust in air is present continously, or for long periods or frequently. Zone 21 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally. Zone 22 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only. Equipment Group I-Mines II – Other Places Explosive atmosphere Continuously, for a long period frequently Occasionally Rarely and for a short period Hazardous places Zone 0 Zone 20 Zone 1 Zone 21 Zone 2 Zone 22 Equipment category M1 or M2 1G 1D 2G 2D 3G 3D EPL (IEC/EN 60079-0) Ma or Mb Ga Da Gb Db Gc Dc 1 2a 2b Class I Zone 1 AEx d IIC T5/T6 Ga/Gb 10 15 16 13 17 18 17 Hazard Class Permitted Division Permitted Group Temperature Class U.S. Enclosure Type Permitted Zone A = American National Standard Ex = Explosion Protected Type of Protection Explosion Group EPL-Equipment Protection Level 10 11 13 15 16 18 12 19 19 14 Type of Protection Code Country Application Protection Principle Standard General requirements US Class I, Division 1 and 2 FM 3600 CA Class I, Division 1 and 2 CSA C22.2 No. 0 AEx US Class I, Division 1 and 2 ISA 60079-0 Ex CA Class I, Division 1 and 2 CSA C22.2 No. 60079-0 Increased safety AEx e (or AEx eb) US Class I, Zone 1 No arcs, sparks or hot surfaces ISA 60079-7 Ex e CA Class I, Zone 1 CSA C22.2 No. 60079-7 Non-incendive (NI) US Class I, Division 2 FM 3611 (NI) CA Class I, Division 2 CSA C22.2 No. 213 Non-sparking AEx nA (or AEx nAc) US Class I, Zone 2 ISA 60079-15 Ex nA CA Class I, Zone 2 CSA C22.2 No. 60079-15 Explosionproof (XP) US Class I, Division 1 Contain the explosion and extinguish the flame FM 3615 (XP) CA Class I, Division 1 CSA C22.2 No. 30 Flameproof AEx d (or AEx db) US Class I, Zone 1 ISA 60079-1 Ex d CA Class I, Zone 1 CSA C22.2 No. 60079-1 Powder-filled AEx q (or AEx qb) US Class I, Zone 1 ISA 60079-5 Ex q CA Class I, Zone 1 CSA C22.2 No. 60079-5 Enclosed break AEx nC (or AEx nCc) US Class I, Zone 2 ISA 60079-15 Ex nC CA Class I, Zone 2 CSA C22.2 No. 60079-15 Intrinsic safety (I.S.) US Class I, Division 1 Limit energy of sparks and surface temperature FM 3610 (I.S.) CA Class I, Division 1 CSA C22.2 No.157 AEx ia US Class I, Zone 0 FM 3610 Ex ia CA Class I, Zone 0 CSA C22.2 No. 60079-11 AEx ib US Class I, Zone 1 FM 3610 Ex ib CA Class I, Zone 1 CSA C22.2 No. 60079-11 AEx ic US Class I, Zone 2 FM 3610 Ex ic CA Class I, Zone 2 CSA C22.2 No. 60079-11 Limited energy AEx nC (or AEx nCc) US Class I, Zone 2 ISA 60079-15 Ex nL CA Class I, Zone 2 CSA C22.2 No. 60079-15 Pressurized Type X US Class I, Division 1 Keep flammable gas out FM 3620 (NFPA 496) Type X CA Class I, Division 1 NFPA 496 Type Y US Class I, Division 1 FM 3620 (NFPA 496) Type Y CA Class I, Division 1 NFPA 496 Type Z US Class I, Division 2 FM 3620 (NFPA 496) Type Z CA Class I, Division 2 NFPA 496 AEx px (or AEx pxb) US Class I, Zone 1 ISA 60079-2 Ex px CA Class I, Zone 1 CSA C22.2 No. 60079-2 AEx py (or AEx pyb) US Class I, Zone 1 ISA 60079-2 Ex py CA Class I, Zone 1 CSA C22.2 No. 60079-2 AEx pz (or AEx pzc) US Class I, Zone 2 ISA 60079-2 Ex pz CA Class I, Zone 2 CSA C22.2 No. 60079-2 Restricted breathing AEx nR (or AEx nRc) US Class I, Zone 2 ISA 60079-15 Ex nR CA Class I, Zone 2 CSA C22.2 No. 60079-15 Encapsulation AEx ma US Class I, Zone 0 ISA 60079-18 Ex ma CA Class I, Zone 1 CSA C22.2 No. 60079-18 AEx m US Class I, Zone 1 ISA 60079-18 AEx mb US Class I, Zone 1 ISA 60079-18 Ex mb CA Class I, Zone 1 CSA C22.2 No. 60079-18 AEx mc US Class I, Zone 2 ISA 60079-18 Ex mc CA Class I, Zone 2 CSA C22.2 No. 60079-18 Liquid immersion AEx o (or AEx ob) US Class I, Zone 1 ISA 60079-6 Ex o CA Class I, Zone 1 CSA C22.2 No. 60079-6 10 Group Substance Hazard Class NEC 500 NEC 505 Acetylene Class I Group A IIC Hydrogen Group B IIC Ethylene Group C IIB Propane Group D IIA Methane (mining) Group D Metal (conductive) dust Class II Group E Coal (carbonaceous) dust Group F Grain dust Group G Combustible fibers and flyings Class III, fibers and flyings Temperature Classes NEC 505 (US) NEC 500 (US) Max. Surface Temperature T1 T1 450 °C T2 T2 300 °C T2A 280 °C T2B 260 °C T2C 230 °C T2D 215 °C T3 T3 200 °C T3A 180 °C T3B 165 °C T3C 160 °C T4 T4 135 °C T4A 120 °C T5 T5 100 °C T6 T6 85 °C Area Classification Flammable Material/ Present Continously Flammable Material/ Present Intermittently Flammable Material/ Present Abnormally NEC 505 (US) NEC 500 (US) Zone 0 Zone 1 Zone 2 Division 1 Division 2 CEC Section 18 (CA) CEC Annex J (CA) Zone 0 Zone 1 Zone 2 Division 1 Division 2 US classification per ANSI/NFPA 70 National Electrical Code (NEC) Article 500 or Article 505 CA classification per CSA C22.1 Canadian Electrical Code (CEC) Section 18 or Annex J Balluff GmbH · Schurwaldstrasse 9 · 73765 Neuhausen a.d.F. · Germany Phone +49 7158 173-0 · Fax +49 7158 5010 · [email protected] · www.balluff.com Doc. No. 922419/Mat. · K18 · Subject to modification · Replaces E16. 11 16 17 18 13 Information and illustrations are non-binding. We reserve the right to changes in technology, form and features. No claims shall be recognized from specifications or illustrations. 15 12 6b 10 Explosion Groups Gas IIA IIB IIC Ignition Temperature Temperature Class Ammonia, methane, ethane, propane Town gas, acrylonitrile Hydrogen > 450 °C T1...T6 Ethanol, cyclohexane, n-butane Ethylene, ethylene oxide Acetylene > 300...450 °C T2...T6 Gasoline, kerosene, n-hexane Ethylene glycol, hydrogen sulfide > 200...300 °C T3...T6 Acetic aldehyde Ethyl ether > 135...200 °C T4...T6 > 100...135 °C T5...T6 Carbon disulfide > 85...135 °C T6...T6 Ignition Temperature of Gases and Vapors Max. Surface Temperature on the Equipment Temperature Class > 450 °C 450 °C T1 > 300...450 °C 300 °C T2 > 200...300 °C 200 °C T3 > 135...200 °C 135 °C T4 > 100...135 °C 100 °C T5 > 85...135 °C 85 °C T6 Explosion Groups Dust IIIA IIIB IIIC Ignition Temperature Temperature Class Combustible flyings Non-conductive dust Conductive dust Surface temperature is specified directly Non Protection Type for Electrical Apparatus Type of Protection Symbol Symbol Alternative EPL For Zone Standard Definition Increased safety e eb ec Gb Gc 1 2 EN 60079-7 Additional measures are applied to prevent the possibility of inadmissibly high temperatures and the occurrence of sparks or electric arcs within the enclosure or on exposed parts of electrical equipment, where such ignition sources would not occur in normal service. Flameproof enclosures d da db dc Ga Gb Gc 0 1 2 EN 60079-1 Parts which can ignite a potentially explosive atmosphere are surrounded by an enclosure which withstands the pressure of an explosive mixture exploding inside the enclosure and prevents the transmission of the explosion to the atmosphere surrounding the enclosure. Pressurized enclosures px py pz pxb pyb pzc Gb, Db Gb, Db Gc, Dc 1, 21 1, 21 2, 22 EN 60079-2 The formation of a potentially explosive atmosphere inside an enclosure is prevented by maintaining a positive internal pressure of protective gas in relation to the surrounding atmosphere and by supplying the inside of the enclosure with a constant flow of protective gas which dilutes any combustible mixtures. Intrinsic safety i ia ib ic Ga, Da Gb, Db Gc, Dc 0, 20 1, 21 2, 22 EN 60079-11 Equipment only contains intrinsically safe electric circuits. An electric circuit is intrinsically safe if any spark or thermal effect produced under normal operation is not capable of causing ignition of a given explosive atmosphere. Oil immersion o ob oc Gb Gc 1 2 EN 60079-6 Equipment are immersed in a protective fluid (e. g. oil) in such a way that a potentially explosive atmosphere existing above the surface or outside of the encapsulation cannot be ignited. Powder filling q qb qc Gb Gc 1 2 EN 60079-5 Filling the enclosure with a fine grained packing material has the effect of making it impossible for an electric arc created in the enclosure under normal operating conditions to ignite a potentially explosive atmosphere surrounding the enclosure. Ignition must neither be caused by flames nor by elevated temperatures on the enclosure surface. Encapsulation m ma mb mc Ga, Da Gb, Db Gc, Dc 0, 20 1, 21 2, 22 EN 60079-18 Parts that are capable of igniting an explosive atmosphere are enclosed in a compound in such a way that ignition of an explosive atmosphere is prevented. Type of protection „n“ Non-sparking Spark-proof Restricted breathing nA nC nR nAc nCc nRc Gc Gc Gc 2 2 2 EN 60079-15 Additional measures are applied to prevent the occurrence of sparks or electric arcs within the enclosure, where such ignition sources would not occur in normal service. Protection by enclosures ta tb tc Da Db Dc 20 21 22 EN 60079-31 Tightness of the enclosure prevents ingress of dust or limits it to a nonhazardous amount. The surface temperature of the enclosure must not ignite the surrounding atmosphere. IPXX 5a 6a 5b Balluff DEX Balluff NEX 4 7 Balluff EEX ZONE 0 ZONE 1 BTL_-_ _ _-M_ _ _ _-J-DEXC-TA12 ZONE 2 BTL_-_ _ _-M_ _ _ _-_-NEX-_ _ _ _ BTL_-_ _ _-M_ _ _ _-_-DEX_-_ _ _ _ WE PROVIDE POSITION FEEDBACK AND SENSORS FOR HAZARDOUS AREAS Explanation of Markings 500 bar Detect end-of-travel positions Position feedback Applications Zone 0 Zone 1 Level monitoring For further information about products with Ex certificates please refer to www.balluff.com/sensors-with-ex-certificates Gas II 1/2G Dust II 1/2D Ex db IIC T6/T5 Ga/Gb Ta +65 °C (T6) + 80 °C (T5) Ex tb IIIC T85/T100 °C Da IP68 Ta +65 °C (T85) + 80 °C (T100) 1 2a 2b 1 3 4 5a 6a 7 9 9 8 7 6b 4 3 5b Zone 21 (2D) Zone 20 (1D) Zone 22 (3D) Zone 1 Division 1 Zone 0 Division 1 Zone 2 Division 2 Zone 0 Division 1 Zone 2 (3G) Zone 1 (2G) Zone 0 (1G)

Upload: others

Post on 26-Jun-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WE PROVIDE POSITION FEEDBACK AND SENSORS FOR …€¦ · NEC Class I Division 1 Groups ABCD T5/T6 Class II Division 1 Groups EFG T5/T6 10 Class III Enclosure Type 4X/6P Ambient Temperature

NECClass I Division 1 Groups ABCD T5/T6 Class II Division 1 Groups EFG T5/T6 Class III Enclosure Type 4X/6P

Ambient Temperature Range: –40...+65 °C (T6) or –40...+80 °C (T5)10 14

10 11 12 13

10 11 12 13

Marking according to NEC 500 (US)/CEC Annex J (CA)

Equipment GroupEquipment Category Gas (/= marking of a device with two categories) Equipment Category DustEx for Electrical ApparatusType of ProtectionExplosion Group GasExplosion Group DustTemperature Class (Gas)Max. Surface Temperature (Dust)EPL-Equipment Protection LevelIP-CodeMax. Ambient Temperature

6a

12a

345a

6b

2b

789

5b

ATEX IECExMarking according to EU directive 2014/34/EU (ATEX) Marking according to EN 60079 and IEC 60079

Equipment Group DefinitionI Equipment group I applies to equipment intended for use in underground parts

of mines, and to those parts of surface installations of such mines, liable to be endangered by firedamp and/or combustible dust.

II Equipment group II applies to equipment intended for use in other places liable to be endangered by explosive atmospheres.

Zone DefinitionZone 0 A place in which a hazardous explosive atmosphere consisting of a mixture with air of

flammable substances in the form of gas, vapor or mist is present continuously or for long periods or frequently.

Zone 1 A place in which an explosive atmosphere consisting of a mixture of air with flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally.

Zone 2 A place in which an explosive atmosphere consisting of a mixture of air with flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

Zone 20 A place in which an explosive atmosphere in the form of a cloud of combustable dust in air is present continously, or for long periods or frequently.

Zone 21 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally.

Zone 22 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

Equipment Group I-Mines II – Other PlacesExplosive atmosphere Continuously, for a long

period frequentlyOccasionally Rarely and for a short

periodHazardous places Zone 0 Zone 20 Zone 1 Zone 21 Zone 2 Zone 22Equipment category M1 or M2 1G 1D 2G 2D 3G 3DEPL (IEC/EN 60079-0) Ma or Mb Ga Da Gb Db Gc Dc

1

2a 2b

Class I Zone 1 AEx d IIC T5/T6 Ga/Gb10 15 16 1317 18

17

Hazard ClassPermitted DivisionPermitted GroupTemperature ClassU.S. Enclosure TypePermitted ZoneA = American National Standard Ex = Explosion ProtectedType of ProtectionExplosion GroupEPL-Equipment Protection Level

1011

13

1516

18

12

19

19

14

Type of Protection Code Country Application Protection Principle

Standard

General requirements US Class I, Division 1 and 2 FM 3600CA Class I, Division 1 and 2 CSA C22.2 No. 0

AEx US Class I, Division 1 and 2 ISA 60079-0Ex CA Class I, Division 1 and 2 CSA C22.2

No. 60079-0Increased safety AEx e (or AEx eb) US Class I, Zone 1

No arcs, sparks or hot surfaces

ISA 60079-7Ex e CA Class I, Zone 1 CSA C22.2

No. 60079-7Non-incendive (NI) US Class I, Division 2 FM 3611

(NI) CA Class I, Division 2 CSA C22.2 No. 213Non-sparking AEx nA (or AEx nAc) US Class I, Zone 2 ISA 60079-15

Ex nA CA Class I, Zone 2 CSA C22.2 No. 60079-15

Explosionproof (XP) US Class I, Division 1

Contain the explosion and extinguish the flame

FM 3615(XP) CA Class I, Division 1 CSA C22.2 No. 30

Flameproof AEx d (or AEx db) US Class I, Zone 1 ISA 60079-1Ex d CA Class I, Zone 1 CSA C22.2

No. 60079-1Powder-filled AEx q (or AEx qb) US Class I, Zone 1 ISA 60079-5

Ex q CA Class I, Zone 1 CSA C22.2 No. 60079-5

Enclosed break AEx nC (or AEx nCc) US Class I, Zone 2 ISA 60079-15Ex nC CA Class I, Zone 2 CSA C22.2

No. 60079-15Intrinsic safety (I.S.) US Class I, Division 1

Limit energy of sparks and surface temperature

FM 3610(I.S.) CA Class I, Division 1 CSA C22.2 No.157AEx ia US Class I, Zone 0 FM 3610Ex ia CA Class I, Zone 0 CSA C22.2

No. 60079-11AEx ib US Class I, Zone 1 FM 3610Ex ib CA Class I, Zone 1 CSA C22.2

No. 60079-11AEx ic US Class I, Zone 2 FM 3610Ex ic CA Class I, Zone 2 CSA C22.2

No. 60079-11Limited energy AEx nC (or AEx nCc) US Class I, Zone 2 ISA 60079-15

Ex nL CA Class I, Zone 2 CSA C22.2 No. 60079-15

Pressurized Type X US Class I, Division 1

Keep flammable gas out

FM 3620 (NFPA 496)Type X CA Class I, Division 1 NFPA 496Type Y US Class I, Division 1 FM 3620 (NFPA 496)Type Y CA Class I, Division 1 NFPA 496Type Z US Class I, Division 2 FM 3620 (NFPA 496)Type Z CA Class I, Division 2 NFPA 496AEx px (or AEx pxb) US Class I, Zone 1 ISA 60079-2Ex px CA Class I, Zone 1 CSA C22.2

No. 60079-2AEx py (or AEx pyb) US Class I, Zone 1 ISA 60079-2Ex py CA Class I, Zone 1 CSA C22.2

No. 60079-2AEx pz (or AEx pzc) US Class I, Zone 2 ISA 60079-2Ex pz CA Class I, Zone 2 CSA C22.2

No. 60079-2Restricted breathing AEx nR (or AEx nRc) US Class I, Zone 2 ISA 60079-15

Ex nR CA Class I, Zone 2 CSA C22.2 No. 60079-15

Encapsulation AEx ma US Class I, Zone 0 ISA 60079-18Ex ma CA Class I, Zone 1 CSA C22.2

No. 60079-18AEx m US Class I, Zone 1 ISA 60079-18AEx mb US Class I, Zone 1 ISA 60079-18Ex mb CA Class I, Zone 1 CSA C22.2

No. 60079-18AEx mc US Class I, Zone 2 ISA 60079-18Ex mc CA Class I, Zone 2 CSA C22.2

No. 60079-18Liquid immersion AEx o (or AEx ob) US Class I, Zone 1 ISA 60079-6

Ex o CA Class I, Zone 1 CSA C22.2 No. 60079-6

10GroupSubstance Hazard Class NEC 500 NEC 505Acetylene

Class I

Group A IICHydrogen Group B IICEthylene Group C IIBPropane Group D IIAMethane (mining) Group DMetal (conductive) dust

Class II

Group ECoal (carbonaceous) dust Group FGrain dust Group GCombustible fibers and flyings Class III, fibers and flyings

Temperature ClassesNEC 505 (US) NEC 500 (US) Max. Surface TemperatureT1 T1 450 °CT2 T2 300 °C

T2A 280 °CT2B 260 °CT2C 230 °CT2D 215 °C

T3 T3 200 °CT3A 180 °CT3B 165 °CT3C 160 °C

T4 T4 135 °CT4A 120 °C

T5 T5 100 °CT6 T6 85 °C

Area ClassificationFlammable Material/Present Continously

Flammable Material/Present Intermittently

Flammable Material/Present Abnormally

NEC 505 (US)NEC 500 (US)

Zone 0 Zone 1 Zone 2Division 1 Division 2

CEC Section 18 (CA)CEC Annex J (CA)

Zone 0 Zone 1 Zone 2Division 1 Division 2

US classification per ANSI/NFPA 70 National Electrical Code (NEC) Article 500 or Article 505CA classification per CSA C22.1 Canadian Electrical Code (CEC) Section 18 or Annex J

Balluff GmbH · Schurwaldstrasse 9 · 73765 Neuhausen a.d.F. · GermanyPhone +49 7158 173-0 · Fax +49 7158 5010 · [email protected] · www.balluff.com

Doc. No. 922419/Mat. · K18 · Subject to modification · Replaces E16.

11

1617

18

13

Info

rmat

ion

and

illust

ratio

ns a

re n

on-b

indi

ng. W

e re

serv

e th

e rig

ht to

cha

nges

in te

chno

logy

, for

m a

nd fe

atur

es. N

o cl

aim

s sh

all b

e re

cogn

ized

from

spe

cific

atio

ns o

r illu

stra

tions

.

15

12

6b

10

Explosion GroupsGasIIA IIB IIC Ignition Temperature Temperature ClassAmmonia, methane, ethane, propane

Town gas, acrylonitrile Hydrogen > 450 °C T1...T6

Ethanol, cyclohexane,n-butane

Ethylene, ethylene oxide Acetylene > 300...450 °C T2...T6

Gasoline, kerosene, n-hexane

Ethylene glycol,hydrogen sulfide

> 200...300 °C T3...T6

Acetic aldehyde Ethyl ether > 135...200 °C T4...T6> 100...135 °C T5...T6

Carbon disulfide > 85...135 °C T6...T6

Ignition Temperature of Gases and Vapors

Max. Surface Temperature on the Equipment

Temperature Class

> 450 °C 450 °C T1> 300...450 °C 300 °C T2> 200...300 °C 200 °C T3> 135...200 °C 135 °C T4> 100...135 °C 100 °C T5> 85...135 °C 85 °C T6

Explosion GroupsDustIIIA IIIB IIIC Ignition Temperature Temperature ClassCombustible flyings Non-conductive dust Conductive dust Surface temperature is

specified directlyNon

Protection Type for Electrical ApparatusType of Protection Symbol Symbol

AlternativeEPL For Zone Standard Definition

Increased safety e ebec

GbGc

12

EN 60079-7 Additional measures are applied to prevent the possibility of inadmissibly high temperatures and the occurrence of sparks or electric arcs within the enclosure or on exposed parts of electrical equipment, where such ignition sources would not occur in normal service.

Flameproof enclosures d dadbdc

GaGbGc

012

EN 60079-1 Parts which can ignite a potentially explosive atmosphere are surrounded by an enclosure which withstands the pressure of an explosive mixture exploding inside the enclosure and prevents the transmission of the explosion to the atmosphere surrounding the enclosure.

Pressurized enclosures pxpypz

pxbpybpzc

Gb, DbGb, DbGc, Dc

1, 211, 212, 22

EN 60079-2 The formation of a potentially explosive atmosphere inside an enclosure is prevented by maintaining a positive internal pressure of protective gas in relation to the surrounding atmosphere and by supplying the inside of the enclosure with a constant flow of protective gas which dilutes any combustible mixtures.

Intrinsic safety i iaibic

Ga, DaGb, DbGc, Dc

0, 201, 212, 22

EN 60079-11 Equipment only contains intrinsically safe electric circuits. An electric circuit is intrinsically safe if any spark or thermal effect produced under normal operation is not capable of causing ignition of a given explosive atmosphere.

Oil immersion o oboc

GbGc

12

EN 60079-6 Equipment are immersed in a protective fluid (e. g. oil) in such a way that a potentially explosive atmosphere existing above the surface or outside of the encapsulation cannot be ignited.

Powder filling q qbqc

GbGc

12

EN 60079-5 Filling the enclosure with a fine grained packing material has the effect of making it impossible for an electric arc created in the enclosure under normal operating conditions to ignite a potentially explosive atmosphere surrounding the enclosure. Ignition must neither be caused by flames nor by elevated temperatures on the enclosure surface.

Encapsulation m mambmc

Ga, Da Gb, DbGc, Dc

0, 201, 212, 22

EN 60079-18 Parts that are capable of igniting an explosive atmosphere are enclosed in a compound in such a way that ignition of an explosive atmosphere is prevented.

Type of protection „n“ Non-sparking

Spark-proofRestricted breathing

nA

nCnR

nAc

nCcnRc

Gc

GcGc

2

22

EN 60079-15 Additional measures are applied to prevent the occurrence of sparks or electric arcs within the enclosure, where such ignition sources would not occur in normal service.

Protection by enclosures tatbtc

DaDbDc

202122

EN 60079-31 Tightness of the enclosure prevents ingress of dust or limits it to a nonhazardous amount. The surface temperature of the enclosure must not ignite the surrounding atmosphere.IPXX

5a

6a

5b

Balluff DEX

Balluff NEX

47

Balluff EEX

ZONE 0

ZONE 1

BTL_-_ _ _-M_ _ _ _-J-DEXC-TA12

ZONE 2

BTL_-_ _ _-M_ _ _ _-_-NEX-_ _ _ _BTL_-_ _ _-M_ _ _ _-_-DEX_-_ _ _ _

WE PROVIDE POSITION FEEDBACK AND SENSORS FOR HAZARDOUS AREAS

Explanation of Markings

500 bar

Detect end-of-travel positions

Position feedback

Applications

Zone 0

Zone 1

Level monitoring

For further information about products with Ex certificates please refer to www.balluff.com/sensors-with-ex-certificates

Gas II 1/2G

Dust II 1/2D

Ex db IIC T6/T5 Ga/Gb Ta +65 °C (T6) + 80 °C (T5)

Ex tb IIIC T85/T100 °C Da IP68 Ta +65 °C (T85) + 80 °C (T100)1 2a

2b1

3 4 5a 6a 7 9

9876b43 5b

Zone 21 (2D)

Zone 20 (1D)

Zone 22 (3D)

Zone 1Division 1

Zone 0Division 1

Zone 2Division 2

Zone 0Division 1

Zone 2 (3G)

Zone 1 (2G)

Zone 0 (1G)