GETTING STARTED iW PDS-150 is a robust 24 VDC, 150 W power source and intelligent data drive circuitry specifically designed for use with IntelliWhite Series fixtures. This guide contains important information on installing and using your new iW PDS-150 safely and carefully. Please read it carefully and save it for future reference. This power supply is not suited for outdoor locations and must be shielded from water spray. Included in this Box • iW PDS-150 power supply / data circuit module • 6 - Module-to-housing mounting screws and lock washers • Housing • Cover with 8 mounting screws • EMI Suppression Core • Spare fuses • Data Terminator • Cable Strain Relief • Installation Instructions Additional Items Needed • Mounting hardware • Power screwdriver • Small screwdriver • Wire nuts Scope of this Document The scope of this document is to explain the steps necessary to install the iW PDS-150 and assure peak performance. Its intended use is for reference only, by persons who are fully qualified. This document should never be considered a substitute for any provisions of a regulation or state and / or local code. Identification and Warnings of Safety Hazards In accordance with ANSI Z535.4-2002 the following system of identifying the severity of the hazards associated with the products is used: DANGERImminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING” Potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION” Potentially hazardous situation which, if not avoided, may result in minor or moderate injury or property damage. Also used to alert against unsafe practices. IGNORING A HAZARD WILL VOID ANY WARRANTY. DANGER: Ensure that main power supply is off before installing, wiring, or servicing the iW PDS-150 power supply. WARNING: The iW PDS-150 is rated for installation in environments where the temperature does not exceed 122˚F (50˚C). To ensure product performance, 4 inches of open space is required around all vented sides of the unit. Do not obstruct the vent holes on the housing cover. WARNING: The iW PDS-150 power supply must be installed without any ventilation openings facing down. WARNING: The iW PDS-150 power supply must be installed by a qualified professional in accordance with NEC and relevant local codes. WARNING: Do not attempt to install or use the iW PDS-150 until you read and understand the installation instructions and safety labels. WARNING: Do not use the iW PDS-150 if power cables are damaged. WARNING: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to take adequate measures. CAUTION: Do not hot swap. Ensure the power supply is disconnected from line AC before connecting or disconnecting fixtures. CAUTION: Do not use with dimmers. CAUTION: Do not modify or alter the iW PDS-150. NOTE: The instructions and precautions set forth in this user guide are not necessarily all inclusive, all conceivable, or relevant to all applications as Philips Solid-State Lighting Solutions cannot anticipate all conceivable or unique situations. Owner / User Responsibilities It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate the iW PDS-150 in such a manner as to comply with all state and local laws, ordinances, regulations, and the American national Standard Institute Safety Code. INSTALLING THE iW PDS-150 The iW PDS-150 must be installed by a qualified electrician in accordance with NEC and relevant local codes for power supplies with Class 2 outputs. A power screwdriver is recommended for mounting the unit. CAUTION: In any wiring configuration, do not exceed the maximum fixtures per group recommended below: Fixture Max. per iW PDS-150 Max. per fuse group iW Blast 12 TR 3 1 iW Profile g2 10 5 Installation Considerations Zones. The iW PDS-150 uses the iW Scene Controller to control IntelliWhite dimmable, color temperature adjustable fixtures by zones. A zone is a grouping of lights attached to an iW power / data supply which has been set to a specified zone designation. The zone designation of the iW power / data supply defines the zone in which the lights reside. Using the iW Scene Controller, you can set the brightness level and color temperature, from cool to warm, for all lights within specified zones. Zones are created by internally designating each iW PDS-150 as a specific alphanumeric zone, 1 – 9 or A – F. All fixtures attached to that iW PDS-150 reside within the designated zone. For example, in an installation with two iW PDS-150s where the first power / data supply is set to Zone 1 and the second is set to Zone 2, the lights attached to the first iW PDS-150 are in Zone 1 and the lights attached to the second iW PDS-150 are in Zone 2. For installations where all lights are controlled in unison, set each power / data supply in the installation to the same zone designator. For installations where groups of lights are controlled individually, set unique zone designators for each power / data supply. Location of iW PDS-150 in relationship to lights. Refer to the user guide for your IntelliWhite fixture to determine the maximum distance from the fixture to install the iW PDS-150. NOTE: Adhere to all state and local wiring codes when making the leader extension connections. Maximum number of fixtures per iW PDS-150. Refer to the user guide for your IntelliWhite fixtures to determine the maximum number of fixtures per iW PDS-150 and the maximum number of fixtures per fuse group. STEPS TO A SUCCESSFUL INSTALLATION 1. Set the zone(s) for the iW PDS-150s. 2. Install the iW PDS-150. 3. Wire the iW PDS-150. 4. Connect the iW Scene Controller. Setting the iW Power / Data Supply Zone To minimize installation time and effort, set the zone for each iW PDS-150 prior to installation. Zones can be set or changed after installing the iW PDS-150; however, any settings or changes made after power is engaged requires a power cycle to recognize the change. Using a small, flat-head screw driver, set the zone for the iW PDS-150 by rotating the zone switch (located to the right of the Zone Net Out port) to a specific designator 1 – 9 or A – F. The designator zero (0) is reserved for future features. (See Fig. 1.) Installing the iW PDS-150 • Select the location to mount the housing, keeping the iW PDS-150 within the maximum distance specified for your fixture and controller. Refer to user guides for the cable run information. NOTE: Specifications for specific fixtures supersede this information. In certain conditions the maximum cable run is less than 60 feet. • Prior to mounting, punch out the appropriate number of pre-formed conduit holes. • Mount the housing to a flat surface using four screws suitable for the mounting surface. Mounting holes are located at each corner of the bottom of the housing. (See mounting details in Fig. 2.) Mounting the Power / Data Module in the Housing • Mount the Power / Data module prior to pulling the wiring into the housing. • Mount the Power / Data module to the stand-off holes in the bottom of the housing using the provided mounting screws and lock washers. Mate the slotted hole of the board to the PEM mount referenced in Fig. 2. (See Fig. 3 for the correct orientation.) iW PDS-150 INSTALLATION INSTRUCTIONS Philips Solid-State Lighting Solutions, Inc. 3 Burlington Woods Drive Burlington, Massachusetts 01803 USA Tel 888.Full.RGB Tel 617.423.9999 Fax 617.423.9998 www.colorkinetics.com Item # 509-000001-00 Copyright © 2008 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorGraze, ColorPlay, ColorReach, DIMand, EssentialWhite, eW, iColor, iColor Cove, IntelliWhite, iW, iPlayer, Light Without Limits, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. PUB-000124-00 Rev 03 Specifications subject to change without notice. Refer to www.colorkinetics.com for the most recent version. MATE SLOTTED HOLE OF BOARD HERE PEM MOUNTS FOR FOR POWER / DATA MODULE, #8 MOUNTING SCREWS (PROVIDED) .25 in (6 mm) HOUSING MOUNTING HOLES 8.58 in (218 mm) 9.75 in (248 mm) Fig. 2 OPEN FRONT CONDUIT SIDE VENTED SIDE POWER SUPPLY POWER / DATA MODULE Fig. 3 RED WHT BLK RED WHT BLK CONTROLLER ZONE NET IN ZONE NET OUT ZONE NUMBER Output Fault Zone Net Heart Beat ZONE NUMBER OUT Fig. 1 An IntelliWhite Product™

Upload: others

Post on 16-Oct-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: W PdS-150 identification and Warnings of Safety Hazards

GettinG StartediW™ PDS-150 is a robust 24 VDC, 150 W power source and intelligent data drive circuitry specifically designed for use with IntelliWhite™ Series fixtures.

This guide contains important information on installing and using your new iW PDS-150 safely and carefully. Please read it carefully and save it for future reference. This power supply is not suited for outdoor locations and must be shielded from water spray.

included in this Box• iW PDS-150 power supply / data circuit module• 6 - Module-to-housing mounting screws and lock washers• Housing • Cover with 8 mounting screws• EMI Suppression Core • Spare fuses• Data Terminator • Cable Strain Relief• Installation Instructions

additional items needed• Mounting hardware • Power screwdriver• Small screwdriver • Wire nuts

Scope of this documentThe scope of this document is to explain the steps necessary to install the iW PDS-150 and assure peak performance. Its intended use is for reference only, by persons who are fully qualified. This document should never be considered a substitute for any provisions of a regulation or state and / or local code.

identification and Warnings of Safety HazardsIn accordance with ANSI Z535.4-2002 the following system of identifying the severity of the hazards associated with the products is used:“danger” Imminently hazardous situation which, if not avoided, will

result in death or serious injury.“warning” Potentially hazardous situation which, if not avoided, could

result in death or serious injury.“caution” Potentially hazardous situation which, if not avoided, may result

in minor or moderate injury or property damage. Also used to alert against unsafe practices.

ignoring a hazard will void any warranty.danger: Ensure that main power supply is off before installing, wiring, or servicing the iW PDS-150 power supply.warning: The iW PDS-150 is rated for installation in environments where the temperature does not exceed 122˚F (50˚C). To ensure product performance, 4 inches of open space is required around all vented sides of the unit. Do not obstruct the vent holes on the housing cover.warning: The iW PDS-150 power supply must be installed without any ventilation openings facing down. warning: The iW PDS-150 power supply must be installed by a qualified professional in accordance with NEC and relevant local codes. warning: Do not attempt to install or use the iW PDS-150 until you read and understand the installation instructions and safety labels. warning: Do not use the iW PDS-150 if power cables are damaged. warning: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to take adequate measures. caution: Do not hot swap. Ensure the power supply is disconnected from line AC before connecting or disconnecting fixtures. caution: Do not use with dimmers. caution: Do not modify or alter the iW PDS-150. note: The instructions and precautions set forth in this user guide are not necessarily all inclusive, all conceivable, or relevant to all applications as Philips Solid-State Lighting Solutions cannot anticipate all conceivable or unique situations.

Owner / User responsibilitiesIt is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate the iW PDS-150 in such a manner as to comply with all state and local laws, ordinances, regulations, and the American national Standard Institute Safety Code.

inStaLLinG tHe iW PdS-150The iW PDS-150 must be installed by a qualified electrician in accordance with NEC and relevant local codes for power supplies with Class 2 outputs. A power screwdriver is recommended for mounting the unit.

caution: In any wiring configuration, do not exceed the maximum fixtures per group recommended below:

Fixture Max. per iW PdS-150 Max. per fuse group

iW Blast 12 TR 3 1

iW Profile g2 10 5

installation Considerations• Zones. The iW PDS-150 uses the iW Scene Controller to control

IntelliWhite dimmable, color temperature adjustable fixtures by zones. A zone is a grouping of lights attached to an iW power / data supply which has been set to a specified zone designation. The zone designation of the iW power / data supply defines the zone in which the lights reside. Using the iW Scene Controller, you can set the brightness level and color temperature, from cool to warm, for all lights within specified zones.

Zones are created by internally designating each iW PDS-150 as a specific alphanumeric zone, 1 – 9 or A – F. All fixtures attached to that iW PDS-150 reside within the designated zone. For example, in an installation with two iW PDS-150s where the first power / data supply is set to Zone 1 and the second is set to Zone 2, the lights attached to the first iW PDS-150 are in Zone 1 and the lights attached to the second iW PDS-150 are in Zone 2.

For installations where all lights are controlled in unison, set each power / data supply in the installation to the same zone designator. For installations where groups of lights are controlled individually, set unique zone designators for each power / data supply.

• Location of iW PdS-150 in relationship to lights. Refer to the user guide for your IntelliWhite fixture to determine the maximum distance from the fixture to install the iW PDS-150. note: Adhere to all state and local wiring codes when making the leader extension connections.

• Maximum number of fixtures per iW PdS-150. Refer to the user guide for your IntelliWhite fixtures to determine the maximum number of fixtures per iW PDS-150 and the maximum number of fixtures per fuse group.

StePS tO a SUCCeSSFUL inStaLLatiOn1. Set the zone(s) for the iW PDS-150s.2. Install the iW PDS-150.3. Wire the iW PDS-150.4. Connect the iW Scene Controller.

Setting the iW Power / data Supply ZoneTo minimize installation time and effort, set the zone for each iW PDS-150 prior to installation. Zones can be set or changed after installing the iW PDS-150; however, any settings or changes made after power is engaged requires a power cycle to recognize the change. Using a small, flat-head screw driver, set the zone for the iW PDS-150 by rotating the zone switch (located to the right of the Zone Net Out port) to a specific designator 1 – 9 or A – F. The designator zero (0) is reserved for future features. (See Fig. 1.)

installing the iW PdS-150• Select the location to mount the housing, keeping the iW PDS-150 within

the maximum distance specified for your fixture and controller. Refer to user guides for the cable run information.nOte: Specifications for specific fixtures supersede this information. In certain conditions the maximum cable run is less than 60 feet.

• Prior to mounting, punch out the appropriate number of pre-formed conduit holes.

• Mount the housing to a flat surface using four screws suitable for the mounting surface. Mounting holes are located at each corner of the bottom of the housing. (See mounting details in Fig. 2.)

Mounting the Power / data Module in the Housing• Mount the Power / Data module prior to pulling the wiring into the

housing.• Mount the Power / Data module to the stand-off holes in the bottom of

the housing using the provided mounting screws and lock washers. Mate the slotted hole of the board to the PEM mount referenced in Fig. 2. (See Fig. 3 for the correct orientation.)

iW PdS-150i n s t a l l a t i o n i n s t r u c t i o n s

Philips Solid-State Lighting Solutions, Inc.3 Burlington Woods DriveBurlington, Massachusetts 01803 USATel 888.Full.RGBTel 617.423.9999Fax 617.423.9998www.colorkinetics.com

item # 509-000001-00

Copyright © 2008 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorGraze, ColorPlay, ColorReach, DIMand, EssentialWhite, eW, iColor, iColor Cove, IntelliWhite, iW, iPlayer, Light Without Limits, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners.

PUB-000124-00 Rev 03

Specifications subject to change without notice. Refer to www.colorkinetics.com for the most recent version.

MATE SLOTTED HOLE OF BOARD HERE

PEM MOUNTS FOR FOR POWER / DATAMODULE, #8 MOUNTING SCREWS (PROVIDED)

.25 in (6 mm) HOUSING MOUNTING HOLES

8.58 in(218 mm)

9.75 in(248 mm)

Fig. 2

OPEN FRONT

CONDUITSIDE

VENTEDSIDE

POWERSUPPLY

POWER / DATAMODULE

Fig. 3

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

CONTROLLER ZONE NETIN

ZONE NETOUT

ZONE NUMBER

Output

Fault

Zone Net

Heart Beat

Power

ZONE NUMBEROUT

Fig. 1

An IntelliWhite Product™

Page 2: W PdS-150 identification and Warnings of Safety Hazards

Wiring the iW PdS-150

After mounting the power / data module, you are ready to connect your IntelliWhite series fixtures.

Connecting intelliWhite Fixtures to the iW PdS-150There are three fuse groups, each having two output terminals on the power supply. Refer to the user guide for your IntelliWhite fixture for the maximum number of fixtures per fuse group allowed.• Connect the fixture cables to the output

terminal connectors. • Ensure that the red, white and black wires

correspond to the 3-pin terminal block notations (See Fig. 4.)

• Snap the terminal connector into the output terminal.

Connecting Power to the iW PdS-150note: It is the end user’s responsibility to use the proper conductors to permanently connect the incoming facility power, and to provide means for disconnecting the system. (See Fig. 5.)

• Connect the incoming power lines to the terminal block located on the power supply.

note: A cable strain relief is required when flexible cable is used for the incoming power source. (See Fig. 6.)

• Connect pig tails to the terminals labeled L (line), N (neutral), and (ground). (See Fig. 6.)

eMi Suppression CoreThe EMI Suppression Core must be installed on the incoming power for effective EMI suppression. Install one round suppression core on the AC power input cable:• Strip the outer cable jacket on the incoming power cable back at least 18

in (457 mm) to allow for three loops through the suppression core.• Pull power cable into the power / data supply. • Insert and pull the line and neutral wires through the center of the EMI

Suppression Core. Insert and pull wires through again twice to form a second and third loop around core. See Fig. 6a.

• Using wire nuts, connect incoming power wires to pig tail wires.• Place the EMI Suppression Core and the associated cables inside the

power / data supply.

Connecting the iW Scene ControllerTo control IntelliWhite fixtures with the iW PDS-150, the iW Scene Controller is required. Depending on the installation configuration, an iW Scene Controller can control one or multiple iW PDS-150s. Refer to the iW Scene Controller Installation Instructions for details.• Install the iW Scene Controller in a single gang wall box within

50 feet (15m) of the iW PDS-150. • Pull the provided iW Scene Controller leader cable into the

iW PDS-150.• Plug the 4-pin connector at the end of the iW Scene Controller Leader

Cable into the connector located on the back of the controller. Plug the other end into the Controller connector located near the Zone Net In connector in the iW PDS-150. (See Fig. 7.)note: The iW Scene Controller provides data to, and receives power from, the iW PDS-150; therefore, no external power supply is needed for the iW Scene Controller.

• For installations that have one iW Scene Controller controlling multiple iW PDS-150s, connect the iW Scene Controller to the first iW PDS-150 in the installation then daisy chain CAT5 cables with RJ45 connectors to the other iW PDS-150s using the Zone Net In and Zone Net Out ports. (See Fig. 8.)Install the provided terminator in the Zone Net Out connector in the iW PDS-150 farthest from the keypad. There should be no more than one terminator for the entire installation, no matter how many iW PDS-150s are used.

rePLaCinG FUSeSwarning: Ensure the power supply is off before connecting or disconnecting fuses. Failure to do so could results in death or serious injury.

Each of the main output terminals is equipped with a fuse. If an output terminal is not functioning, replace the fuse as follows:• Remove the protective fuse cover from the malfunctioning fuse. • Remove the fuse from the malfunctioning fuse terminal. • Insert the replacement fuse into the fuse terminal. Use only 4 amp, 3AG

fuses. Additional replacement fuses are available from Philips.• Replace the protective fuse cover.

iW PdS-150 SPeCiFiCatiOnSpower input 100 – 240 VAC auto ranging (50 – 60 Hz)

Power factor correction (PFC) 2.8 A (115 VAC) / 1.4 A (230 VAC)

power output 24 VDC (150 W Max.)

heat dissipation 25 percent of total power output

ambient operating temp 14° – 122° F (-10° – 50°C)

housing NEMA-style indoor rated enclosure; housing dimensions: 10.38 x 10.10 x 4.38 in (264 x 257 x 111 mm)

connectors Data: 4-pin input and RJ45 data I / O Power: Screw terminal output connectors

data interface IntelliWhite controllers

classification Class 2 power supply

environment Dry Location

listings UL / cUL, CE, PSE

MULTIPLE iW PDS-150 CONTROLiW SceneController

FUSE BLOCK

FUSE BLOCK

FUSE BLOCK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

CONTROLLER ZONE NETIN

ZONE NETOUT

ZONE NUMBER

Output

Fault

Zone Net

Heart Beat

Power

To Lights

iW PDS-150

Terminator

CONTROLLER ZONE NETIN

ZONE NETOUT

ZONE NUMBER

Terminator

FUSE BLOCK

FUSE BLOCK

FUSE BLOCK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

CONTROLLER ZONE NETIN

ZONE NETOUT

ZONE NUMBER

Output

Fault

Zone Net

Heart Beat

Power

To Lights

iW PDS-150

CAT 5 / RJ45

Fig. 8

SINGLE iW PDS-150 CONTROL

iW SceneController

FUSE BLOCK

FUSE BLOCK

FUSE BLOCK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

CONTROLLER ZONE NETIN

ZONE NETOUT

ZONE NUMBER

Output

Fault

Zone Net

Heart Beat

Power

To Lights

iW PDS-150

TerminatorCONTROLLER ZONE NET

INZONE NET

OUTZONE

NUMBER

Terminator

Fig. 7

DIAGNOSTICINDICATOR LIGHTS

24V

DATA

COM

N

L

TERMINATOR

DATA / 24 VDC TO LIGHTS

24V

DATA

COM

FUSE

FUSE

FUSE

FROM CONTROLLER

INCOMINGPOWER100 – 240 VAC

24V

DATA

COM

24V

DATA

COM

24V

DATA

COM

24V

DATA

COM

CONTROLLER ZONE NETIN

ZONE NETOUT

ZONE NUMBER

Output

Fault

Zone Net

Heart Beat

Power

RING TERMINAL

Fig. 5

important: In any wiring configuration, do not exceed the maximum number of IntelliWhite fixtures recommended per group.

danger: Turn off main power supply before wiring the iW PDS-150. Failure to adhere to these instructions will result in death or serious injury.

BLACK

WHITE

RED

COM

DATA

24V

Fig. 4

warning: Make sure the power supply is off before connecting or disconnecting fixtures. Otherwise, damage to the fixture will result.