Vulkem 116Table of Contents

Vulkem 116 Color Chart1

Vulkem 116 Data Sheet2

Vulkem 116 Limestone MSDS (CAN)4

Cold Weather Caulking Instructions10

Vulkem 116 LEED Information Letter12

Sealant Material Warranty13

This guide only offers a general representation of our color offering. Colors viewed on a computer screen and then printed will vary and will never be an exact representation of the actual pigment. When matching is critical, please refer to our color card or sample color strips.

One-Part, High-Performance Polyurethane SealantVulkem® 116

Product DescriptionVulkem® 116 is a one-part, moisture-curing, gun-grade polyurethane sealant. It is durable, flexible, and offers excellent performance in dynamic joints. Features and BenefitsVulkem 116 has a 30-year history of delivering superior primerless adhesion to porous substrates, which makes it the choice for sealing expansion joints in commercial construction applications. Vulkem 116 is also suitable for certain water immersion applications and is rated for 25% movement capability. The cure of the sealant can be accelerated with the addition of the Vulkem Catalyst 45/116.

UsesVulkem 116 is an excellent general-purpose sealant designed for use on poured and precast concrete, masonry work, window and door perimeters, and similar types of construction joints. Vulkem 116 is approved for exterior use only.

ColorsAlmond, Aluminum, Black, Bronze, Buff, Gray, Dark Bronze, Ivory, Limestone, Redwood Tan, Beige, Stone, Anodized Aluminum, Aluminum Stone, White, Natural Clay

Packaging10.1 oz. (300mL) cartridges, 20 oz. (600mL) sausages, 2 and 5 gallon (7.6 and 18.9L) pails, and 55 gallon (208L) drums. All colors are not available in every package size. Contact Tremco Customer Service for more information.

Coverage Rates308 linear feet of joint per gallon for a 1/4 in. x 1/4 in. (6mm x 6mm) joint. For specific coverage rates that include joint size, and usage efficiencies, visit our website usage calculator at www.tremcosealants.com.

Applicable StandardsVulkem 116 meets or exceeds the requirements of the following specifications:• ASTMC920TypeS,GradeNS,Class25,UseT,NT,M,A,I class II, and O• U.S.FederalSpecificationTT-S-00230C,ClassA,TypeII• CAN/CGSB-19.13-M87• USDAregulationforindirectfoodcontact• CanadianFoodInspectionAgency• CityofLosAngeles(COLA)approvalstandards

Joint DesignVulkem 116 may be used in any vertical or horizontal joint designed in accordance with accepted architectural/engineering practices. Joint width should be 4 times anticipated movement, but not less than 1/4 in. (6mm).

Joint BackingClosed cell or reticulated polyethylene backer rod is recommended as joint backing to control sealant depth and to ensure intimate contact of sealant with joint walls when tooling. Where depth of joint will prevent the use of backer rod, an adhesive backed polyethylene tape (bond breaker tape) should be used to prevent three-sided adhesion. All backing should be dry at time of sealant application.

Page 1 of 2

TYPICAL PHYSICAL PROPERTIES(Results of recent testing at 72˚F (22˚C) after 21 days cure time.)

Property Test Method Typical Value ExtrusionRate ASTMC1183 40-50ml/min.HardnessProperties,scale“A” ASTMC661 40WeightLoss ASTMC1246 PassSkin Time (tooling time) 6 hoursTackFreeTime ASTMC679 30hoursStain&ColorChange ASTMC510 Novisiblecolorchange/NostainAdhesion-in-Peel ASTMC794 Aluminum18–22pli(80–99N) Concrete20–25pli(89–111N) Brick19–23pli(85–102N) No Adhesion Loss EffectsofAcceleratedAging ASTMC793 PassMovementCapability ASTMC719 ±25%TensileStrength ASTMD412 200-250psiUltimateElongation ASTMD412 200–300%100%Modulus ASTMD412 150-200psi

www.tremcosealants.com

1113/V116SD Page 2 of 2

Sealant DimensionsW = Sealant width, D = Sealant depth, C = Contact area.

EXPANSION JOINTS - The minimum width and depth of any sealant application should be 1/4 in. x 1/4 in. (6mm x 6mm).

The depth (D) of sealant may be equal to the width (W) of joints that are less than 1/2 in. (13mm) wide. For joints ranging from 1/2 in. to 1 in. (13mm to 25mm) wide, the sealant depth should be approximately one-half of the joint width.

The maximum depth (D) of any sealant application should be 1/2 in. (13mm). For joints that are wider than 1 in. (25mm) contact Tremco’s Technical Service Department, or your local Tremco Sales Representative.

WINDOWPERIMETERS–Forfilletbeads,oranglebeadsaroundwindows and doors, the sealant should exhibit a minimum surface contact area (C) of 1/4 in. (6mm) onto each substrate.

Surface PreparationsSurfaces must be sound, clean, and dry. All release agents, existing waterproofing, dust, loose mortar, laitance, paints or other finishes must be removed. This can be accomplished with a thorough wire brushing, grinding, sandblasting or solvent washing, depending on the contamination.

Tremco recommends that surface temperatures be 40˚F (5˚C) or above at the time the sealant is applied. If sealant must be applied in temperatures below 40˚F, please refer to the Tremco Guide for Applying Sealants in Cold Weather that can be found on our website at www.tremcosealants.com.

PrimingWhere deemed necessary, use Vulkem Primer #171 for porous substratesandTREMprimeNon-PorousPrimerformetalsandplastics. Vulkem 116 typically adheres to common construction substrates without primers; however, Tremco always recommends that mock-up or field adhesion test be performed on the actual materials being used on the job to verify the need for a primer. The field adhesion test can be found in appendix X1ofASTMC1193,StandardGuideforUseofJointSealants.

ApplicationVulkem 116 is easy to apply with conventional caulking equipment. Ensure that the backer rod is friction fitted properly and any primers have been applied. Fill the joint completely with a proper width-to-depth ratio and tool to ensure intimate contact of sealant with joint walls. Dry tooling is always preferred, although xylene can be used in limited amounts to slick the spatula if needed.

For a cleaner finish, mask the sides of the joint with tape prior to filling.

Cure TimeVulkem 116 generally cures at a rate of 1/16 in. (2mm) per day at 75°F (24°C) and 50% relative humidity. It will skin in 5 hours and be tack free in 30 hours. The cure time will increase as temperatures and/or humidity decrease. A good rule of thumb is one additional day for every 10°F decrease in temperature.

Clean UpExcess sealant and smears adjacent to the joint interface can be carefully removed with xylene or mineral spirits before the sealant cures. Any utensils used for tooling can also be cleaned with xylene or mineral spirits.

Limitations• DonotapplyVulkem116overdamporcontaminated surfaces. • Vulkem116isapprovedforexterioruseonly.Donotuse this product inside an occupied building even if there are no occupants present during use.• Alwaysutilizethesealant’sMSDSfoundonourwebsite at www.tremcosealants.com for information on proper ventilation, Personal Protective Equipment (PPE) and other health concerns.• Donotuseinchlorinated,potable,heavyorwastewater.

WarrantyTremco warrants its Products to be free of defects in materials, but makes no warranty as to appearance or color. Since methods of application and on-site conditions are beyond our control and can affect performance, Tremco makes no other warranty, expressed or implied including warranties of MERCHANTABILITYandFITNESSFORAPARTICULARPURPOSE,with respect to Tremco Products. Tremco’s sole obligation shall be, at its option, to replace or refund the purchase of the quantity of Tremco Products proven to be defective, and Tremco shall not be liable for any loss or damage.

Please refer to our website at www.tremcosealants.com for the most up-to-date Product Data Sheets.

Tremco Commercial Sealants & Waterproofing3735 Green Road, Beachwood, OH 44122 // Phone: 216.292.5000 // 800.321.7906

220WicksteedAvenue,Toronto,ONM4H1G7//Phone:416.421.3300//800.363.32131451 Jacobson Avenue, Ashland OH 44805 // Phone: 419.289.2050 // 800.321.6357

www.tremcosealants.com

Material Safety Data Sheet

VULKEM 116 LIMESTONE

Version 2.0 Print Date 06/24/2014 REVISION DATE: 06/23/2014

1/6 426805 323

SECTION 1 - PRODUCT IDENTIFICATION / PREPARATION INFORMATION

Product Information Trade name : VULKEM 116 LIMESTONE

Product code : 426805 323 Supplier : Tremco Canada division

220 Wicksteed Avenue Toronto, ON M4H 1G7

Telephone : (416) 421-3300 Emergency Phone : (613) 996-6666 Product use : Sealant Preparation Information Prepared by: : Sewnauth Raghunandan Date: : 06/23/2014 Telephone : (416) 421-3300

SECTION 2 - HAZARDS IDENTIFICATION

Emergency Overview

Limestone. Non-sag gunnable paste. May cause slight irritation to the respiratory system. May cause nausea, headaches, and dizziness. May cause drowsiness, weakness, and fatigue. May cause allergic respiratory sensitization. Leave area to breathe fresh air. Avoid further overexposure. If symptoms persist, get medical attention. Move to fresh air. If required, artificial respiration or administration of oxygen can be performed by trained personnel. Acute Potential Health Effects/ Routes of Entry

Inhalation : May cause slight irritation to the respiratory system. May cause nausea, headaches, and dizziness. May cause drowsiness, weakness, and fatigue. May cause allergic respiratory sensitization.

Eyes : Direct contact may cause mild irritation. Ingestion : May cause gastrointestinal irritation, nausea, and vomiting. Skin : May cause sensitization resulting in irritation, itching and redness.

Aggravated Medical Conditions

Pre-existing eye, skin and respiratory disorders may be aggravated by exposure.

Chronic Health Effects

Overexposure may cause dermatitis, asthma, skin and respiratory sensitization and decreased lung function. Prolonged or repeated contact/exposure to aromatic petroleum distillates may cause defatting, drying, and irritation of the skin, dermatitis, and central nervous system (CNS) effects. Inhalation of crystalline silica (quartz) can cause cancer based on animal data, and IARC concludes sufficient evidence in humans (Group 1). Prolonged and repeated overexposure to free crystalline silica dust above the TLV level may cause scarring of the lungs with cough and shortness of breath. A delayed lung injury, silicosis may result from breathing free silica. Fillers are encapsulated and not expected to be released from product under normal conditions of use. Target Organs: Skin, Eye, Ingestion, Lung

Material Safety Data Sheet

VULKEM 116 LIMESTONE

Version 2.0 Print Date 06/24/2014 REVISION DATE: 06/23/2014

2/6 426805 323

SECTION 3 : HAZARDOUS INGREDIENTS

Chemical Name CAS-No. Weight % Range

Heavy aromatic naphtha 64742-94-5 3.0 - 7.0 Titanium dioxide 13463-67-7 3.0 - 7.0 4,4'-Methylene bis(phenylisocyanate) 101-68-8 0.1 - 1.0 1,2,4-Trimethylbenzene 95-63-6 0.1 - 1.0 Polymethylene polyphenyl isocyanate 9016-87-9 0.1 - 1.0 1,3,5-Trimethylbenzene 108-67-8 0.1 - 1.0 Crystalline Silica (Quartz)/ Silica Sand 14808-60-7 0.1 - 1.0

The ingredients listed above are hazardous as defined in the controlled products regulation. (CPR).

SECTION 4 - FIRST AID MEASURES

Get immediate medical attention for any significant overexposure.

Inhalation : Leave area to breathe fresh air. Avoid further overexposure. If symptoms persist, get medical attention.Move to fresh air. If required, artificial respiration or administration of oxygen can be performed by trained personnel.

Eye contact : Flush with water for at least 15 minutes while holding eye lids apart. Get medical attention immediately.

Skin contact : Clean area of contact thoroughly using soap and water. If irritation, rash or other disorders develop, get medical attention immediately.

Ingestion : Do not induce vomiting unless advised by a physician. Call nearest Poison Control Center or Physician immediately.

SECTION 5: FIRE / EXPLOSION HAZARDS

Flash point : Not available. Method : Not available.

Burning rate : Non-flammable solid

Lower explosion limit : Not available.

Upper explosion limit : Not available.

Autoignition temperature : Not available.

Extinguishing media : If water fog is ineffective, use carbon dioxide, dry chemical or foam.

Hazardous combustion products

: Carbon monoxide and carbon dioxide can form.Hydrocyanic acid and nitrogen oxides can form.

Protective equipment for firefighters

: Use accepted fire fighting techniques. Wear full firefighting protective clothing, including self-contained breathing apparatus (SCBA).

SECTION 6 - SPILLS / LEAKS / ACCIDENTAL RELEASE MEASURES

Use appropriate protective equipment. Avoid contact with material. Scrape up and transfer to appropriate container for disposal.

Material Safety Data Sheet

VULKEM 116 LIMESTONE

Version 2.0 Print Date 06/24/2014 REVISION DATE: 06/23/2014

3/6 426805 323

SECTION 7 - HANDLING AND STORAGE

Prevent inhalation of vapor, ingestion and contact with skin, eyes and clothing. Preferably use entire contents in one continuous work session. Do not smoke, weld, generate sparks, or use flame near container. Change soiled work clothes frequently. Clean hands thoroughly after handling Do not store or use near food. Keep container closed when not in use. Since emptied containers retain product residue and vapor, observe precautions even after container is emptied. Store under dry warehouse conditions away from heat and all ignition sources.

SECTION 8 - PREVENTIVE MEASURES/EXPOSURE CONTROLS/PERSONAL PROTECTION

Personal protection equipment Respiratory protection : Wear appropriate, properly fitted NIOSH/MSHA approved organic vapor or

supplied air respirator when airborne contaminant level(s) are expected to exceed exposure limits indicated on the MSDS. Follow manufacturer's directions for respirator use.

Hand protection : Use suitable impervious nitrile or neoprene gloves and protective apparel to reduce exposure.

Eye protection : Wear appropriate eye protection.Use safety glasses if eye contact is likely.

Skin and body protection : Use disposable or impervious clothing if work clothing contamination is likely. Remove and wash contaminated clothing before reuse.

Protective measures : Use professional judgment in the selection, care, and use.

Engineering measures : Use general ventilation and/ or local exhaust to reduce the airborne contaminant concentration below the exposure limit listed in the MSDS

Exposure Limits

Chemical Name CAS Number Regulation Limit Form

Titanium dioxide 13463-67-7 Ontario TWAEV: 10 mg/m3 Total dust. ACGIH TWA: 10 mg/m3

4,4'-Methylene bis(phenylisocyanate)

101-68-8 Ontario TWAEV: 0.005 ppm ACGIH TWA: 0.005 ppm

1,2,4-Trimethylbenzene 95-63-6 Ontario TWAEV: 123 mg/m3 ACGIH TWA: 25 ppm

Polymethylene polyphenyl isocyanate

9016-87-9 Ontario TWAEV: 0.005 ppm ACGIH TWA: 0.005 ppm

1,3,5-Trimethylbenzene 108-67-8 Ontario TWAEV: 123 mg/m3 ACGIH TWA: 25 ppm

Crystalline Silica (Quartz)/ Silica Sand

14808-60-7 Ontario TWAEV: 0.10 mg/m3 Respirable fraction. ACGIH TWA: 0.025 mg/m3 Respirable fraction.

SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES

Physical State : Liquid (paste)

Material Safety Data Sheet

VULKEM 116 LIMESTONE

Version 2.0 Print Date 06/24/2014 REVISION DATE: 06/23/2014

4/6 426805 323

Form : Non-sag gunnable paste

Color : Limestone

Odor : Petroleum Solvent

pH : Not available.

Vapour pressure : Not available.

Vapor density : Heavier than air

Melting point/range : Not available.

Freezing point : Not available.

Boiling point/range : Not available.

Water solubility : Insoluble

Evaporation Rate: : Not available.

Specific Gravity : 1.1344

% Volatile Weight : 6 %

SECTION 10 - REACTIVITY / STABILITY

Substances to avoid : Amines.Water or moisture and oxidizing agents.Alcohols.Strong acids.Strong bases.

Stability : Material is stable under normal storage, handling, and use.

Hazardous polymerization : Will not occur.

SECTION 11 - TOXICOLOGICAL INFORMATION

Titanium dioxide, CAS-No.: 13463-67-7 Acute oral toxicity (LD-50 oral) 25,000 mg/kg ( Rat ) 5,000 mg/kg ( Rat ) 5,000 mg/kg ( Rat

) 2,000 mg/kg ( Rat ) 11,000 mg/kg ( Rat ) Acute inhalation toxicity (LC-50) > 6.82 mg/l for 4 h ( Rat ) 3.43 mg/l for 4 h ( Rat ) 5.09 mg/l

for 4 h ( Rat ) > 2.28 mg/l for 4 h ( Rat ) > 3.56 mg/l for 4 h ( Rat )

4,4'-Methylene bis(phenylisocyanate), CAS-No.: 101-68-8

Acute inhalation toxicity (LC-50) 0.369 mg/l for 4 h ( Rat ) 0.38 mg/l for 4 h ( Rat )

SECTION 12 - ECOLOGICAL INFORMATION

No Data Available

SECTION 13 - WASTE DISPOSAL CONSIDERATIONS

Disposal Method : Dispose as hazardous waste according to all local, state, federal and provincial regulations.

Material Safety Data Sheet

VULKEM 116 LIMESTONE

Version 2.0 Print Date 06/24/2014 REVISION DATE: 06/23/2014

5/6 426805 323

SECTION 14 - TRANSPORTATION / SHIPPING DATA

TDG: Not Regulated

CFR / DOT: Not Regulated

IMDG: Not Regulated

SECTION 15 - REGULATORY INFORMATION

North American Inventories: All components are listed or exempt from the TSCA inventory.

This product or its components are listed on, or exempt from the Canadian Domestic Substances List.

Canadian Regulations: WHMIS Classification : D2A, D2B This is a "controlled product" under the Canadian Workplace Hazardous Materials Information System (WHMIS). This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all of the information required by the CPR. Other Regulations: Regulatory VOC (less water and exempt solvent)

: 70 g/l

SECTION 16 - OTHER INFORMATION

HMIS Rating :

Health 2 0 = Minimum 1 = Slight 2 = Moderate 3 = Serious 4 = Severe

Flammability 2

Reactivity 0

PPE

Further information:

For Industrial Use Only. Keep out of Reach of Children. The hazard information herein is offered solely for the consideration of the user, subject to their own investigation of compliance with applicable regulations, including the safe use of the product under every foreseeable condition.

Material Safety Data Sheet

VULKEM 116 LIMESTONE

Version 2.0 Print Date 06/24/2014 REVISION DATE: 06/23/2014

6/6 426805 323

Prepared by: Sewnauth Raghunandan Legend ACGIH - American Conference of Governmental Hygienists OSHA - Occupational Safety and Health Administration

DOT - Department of Transportation PEL - Permissible Exposure Limit

DSL - Domestic Substance List RCRA - Resource Conservation and Recovery Act

EPA - Environmental Protection Agency STEL - Short Term Exposure Limit

HMIS - Hazardous Materials Information System TLV - Threshold Limit Value

IARC - International Agency for Research on Cancer TSCA - Toxic Substances Control Act

MSHA - Mine Safety Health Administration TWA - Time Weighted Average

NDSL - Non-Domestic Substance List V - Volume

NIOSH - National Institute for Occupational Safety and Health VOC - Volatile Organic Compound

NTP - National Toxicology Program WHMIS - Workplace Hazardous Materials Information System

Guide for Applying Sealant in Cold WeatherThe following outlines procedures and recommendations for using Tremco sealants at temperatures lower than 40F. At temperatures below 32˚F the cure rate of our sealants is diminished and the presence of ice and frost on bonding surfaces becomes more likely. Both of these conditions can affect the overall cure adhesion and ultimate performance of the sealants in application.

The following guidelines should be followed in order to optimize the performance of our sealants in cold weather.

1. Warm the sealant for 24 hrs prior to use. Warming to room temperature will help to ensure adequate flow of the sealant and its adhesion after application.

2. Clean any dew, frost or ice from the substrates with an approved solvent such as MEK (methyl ethyl ketone), Toluene or Xylene. These solvents are more effective in lower temperatures than IPA (isopropyl alcohol).

3. Warm the bonding surfaces prior to surface preparation listed in (2). A hair blower or space heater can be used for this purpose. Raising the temperature of the substrate improves its surface energy and receptiveness to the sealant compound.

4. When required primers should be treated in a similar fashion to the sealants listed above. At temperatures lower than 32˚F (0˚C) the primers in question will take longer to dry than at warmer temperatures. Care should be taken to ensure adequate primer dry time prior to sealant application. Tremco primers include Primer # 10 and Tremprime Silicone Porous primer for silicone sealants. Tremco polyurethane sealant primers include Primers 1, 171 and Tremprime Multipurpose primers.

The following are specific guidelines for applying Tremco sealants based on their composition.

1. Water based sealants: Water based sealants such as Tremflex 834 may freeze when stored at temperatures lower than 32˚F (0˚C). Care should be taken to store this sealant at temperatures warmer than 40˚F and to follow the general cold temperature recommendations listed above.

2. Solvent based Sealants: Solvent based sealants such as Tremco 830, Butyl Sealant and Mono 555 should also be stored and applied in accordance with the application procedures listed above. Where appropriate the sealants will cure at a slower rate at lower temperatures due to a reduced evaporation rate of their carrier solvents. Although these sealants will

thicken in response to the lower temperatures they will not freeze. Warming the sealant prior to use will improve the sealant’s flow properties.

3. Moisture cure sealants: Generally these one part sealants which cure by reaction with moisture vapor are also temperature dependant. Therefore they will cure at a slower rate as the temperature drops. Tremco polyurethane and silicone sealants are included in this category. These polyurethane sealants include but are not limited to Vulkem 116,921,45,45 SSL, Dymonic and Dymonic FC. Tremco silicone sealants include Proglaze, Proglaze SSG, Spectrem 1,2,3,4, Tremsil200,600, Spectrem 800,900.

4. Tremco also provides a number of two part silicone and polyurethane sealants that cure chemically although they are also somewhat affected by colder temperatures in a similar manner to the one part sealants discussed above. Cold temperature application procedures listed above should also be observed when applying these sealants. These products include Dymeric 240, Dymeric 240FC and Proglaze II.

Minimum Temperature: Optimally sealants should be applied between 40˚F (4˚C) and 80˚F (27˚C). At temperatures between 0˚F (-18˚C) and 40˚F (4˚C) the sealant should be applied as described above. High performance moisture curing silicone and polyurethane sealants have been applied successfully at temperatures as low as -20˚F (-29˚C) using these techniques.

In addition to temperature the following environmental conditions can affect the cure rate of the sealants in general.

1. Substrates: Moisture curing substrates (ie mortar, EIFS, concrete) require additional cure time in colder climates. Adequate time should be allowed for these substrates to cure prior to application of cleaners and primers prior to sealant application.

2. Dew Point: The dew point is the temperature at which condensation can develop. If the temperature is below the dew point, the affected substrates should be cleaned with solvent using the two rag wipe method to remove the condensation prior to primer and sealant application.

3. Wind Chill: The major effect of wind chill is the accelerated cooling affect on the substrates and sealants. This will directly affect the time available for surface preparation and sealant application. The application characteristics of cooler sealants (ie reduced flow rate) result in less efficient tooling or wet out of the sealant to the substrate.

Page 1 of 2

Application Instructions

www.tremcosealants.com

0508/SS Page 2 of 2

In general any project should be evaluated on an individual basis since environmental conditions can vary significantly from day to day. These climatic variations are very pronounced during the cold weather months. When cold weather sealant application procedures are required please consult your local Tremco sales representative or Technical Services in Beachwood, Ohio for assistance.

Tremco Commercial Sealants & Waterproofing3735 Green Road, Beachwood, OH 44122 // Phone: 216.292.5000 // 800.321.7906

220 Wicksteed Avenue, Toronto, ON M4H 1G7 // Phone: 416.421.3300 // 800.363.32131451 Jacobson Avenue, Ashland OH 44805 // Phone: 419.289.2050 // 800.321.6357

www.tremcosealants.com

March 10, 2014

RE: Vulkem 116 - Green Building Product Information (LEED® Information)

Tremco, as an organization, is committed to quality, responsive to both internal and external customers, our employees, our

community and environment, and we will treat all with respect and good stewardship.

Material Manufacturing Location:

Vulkem 116 is manufactured in Cleveland, Ohio. Should your job site be within 500 straight-line miles of Cleveland, this

material will help contribute positively towards the Locally Manufactured Material Credit.

Raw Material Extraction Information:

No single extracted material is used to produce the majority of this product. Additionally, all raw materials come from one of

several sources which in-turn come from one of several raw material feed stocks. As such, point source for the raw materials

cannot be determined.

Rapidly Renewable Raw Material Information:

Vulkem 116 contains 0% rapidly renewable raw material content by weight.

Recycled Content Information (by weight: All in Packaging):

1 Case of Cartridges 0.2% (All Post Industrial)

1 Case of Sausages 0.28% (All Post Industrial)

2 Gal Bucket 2.53% (2.11% Post Industrial, 0.42% Post Consumer)

5 Gal Bucket 2.61% (2.17% Post Industrial, 0.44% Post Consumer)

1 x 55 Gal Drum 8.21% (All Post Industrial)

VOC Content Information:

Vulkem 116 has a VOC content of 80g/L equaling 2% by weight. These levels are below the SCAQMD levels regardless

of package size.

Additional Information:

Should you have any questions or require additional information, please do not hesitate to contact Technical Services or your

local Tremco Field Representative.

Sincerely,

Amy Woodard

Product Steward

Compliance and Regulatory

Tremco Incorporated 3735 Green Road • Beachwood, Ohio 44122 • 216-292-5000 www.tremcosealants.com Warranty No: ********* Commercial Sealants & Waterproofing Today’s Date: ********* Exp: *********

Sealant Material Warranty

PROJECT NAME

APPLICATOR

ARCHITECT/ENGINEER

GENERAL CONTRACTOR

OWNER

DATE OF SUBSTANTIALCOMPLETION

PRODUCT(S) TYPE OF WORK

Tremco Incorporated (“Tremco”) hereby warrants to the Owner, subject to the terms, conditions and limitations stated herein, that the Tremco Sealant specified above is free of manufacturing defects and conforms to published physical properties and quality control standards in force at the time product was purchased and, when installed in accordance with Tremco’s written Application Instructions and in applications approved by Tremco as suitable for the Product, will have a useful life under normal service conditions for a period of year(s) from the date of substantial completion. In the event the Product is proven not to have performed in accordance with the Warranty during the warranty period, the Owner shall immediately notify Tremco and confirm such notice in writing within thirty (30) days. Tremco’s sole responsibility under this Warranty shall be, at its option, either to refund the purchase price of or provide sufficient replacement material to replace the non-conforming product, and such refund or replacement shall constitute the limit of the Company’s liability and obligation. During the term of this Warranty, agents or employees of Tremco shall be afforded opportunities to inspect any such areas at such time as Tremco may reasonably request. Tremco makes no warranty with respect to appearance or color. Tremco’s obligations under this Warranty are expressly conditioned upon receipt of full payment for the Product and the Owner’s compliance with each of its responsibilities described in this Warranty document. Any delay in full payment to Tremco shall not extend the Warranty Period. No representative of Tremco has the authority to make any representations or provisions except as stated herein. This Warranty is issued to the above-named Owner and is transferable with the written consent of Tremco. THE ABOVE WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, EXCEPT AS EXPRESSLY PROVIDED HEREIN. TREMCO SHALL NOT BE LIABLE FOR DAMAGE TO THE PROJECT STRUCTURE OR INTERIOR CONTENTS OR FOR ANY OTHER CONSEQUENTIAL, SPECIAL OR OTHER DAMAGES ARISING FROM OR RELATED TO, DIRECTLY OR INDIRECTLY, THIS WARRANTY OR THE PERFORMANCE OF THE MATERIALS COVERED BY THIS WARRANTY, WHETHER BASED ON BREACH OF WARRANTY, NEGLIGENCE OR OTHER THEORY OF LIABILITY.

TREMCO INCORPORATED Commercial Sealants & Waterproofing

Michael J. Soeder, VP Sales, NA

TO EXPEDITE PROCESSING, THIS DOCUMENT WILL BE COMPLETED AND DELIVERED IN ELECTRONIC FORM ONLY. AN ELECTRONIC SIGNATURE FROM A TREMCO REPRESENTATIVE ON A COMPLETED WARRANTY DOCUMENT IS VALID AND BINDING AND IS

ENFORCEABLE TO THE SAME EXTENT AS A PENNED SIGNATURE.