I s o a T S t L b o q M in a e g p C It’s time for a surplus of pot order to be m as well as rece …and the a Wastewa The laborator Secretary Cat the Natural Re Lab Director been a team e operators and quick to sha Management nstruments. J and Ryan Hof excellent wor great pride problems whe Congratulation Hammer Analysis of requested d levels can be concentratio toxics will environment As far as w analysis requ near future. TOC results pollutants estimates ca 201 6 Reg Approved nother edition tential articles ore environm ent editions o award goes ater Treatm ry staff were thy Stepp at esources Boa John Nehme effort from D d has passed are credit an for keeping John also cre ffman who tak k for the com in getting en they do co ns, Columbus rTime: only total organ during site ch e an importa n of TOC i be adsorbe t. e can tell, it uests will be Data users s as a mea so that to an be made. i stered Lab Methods f o n of LabNotes s that we can mentally friend of LabNotes o s to… City o ment Plant (W presented th the February rd. er says that ay 1. He lear that knowled nd thanks a them up to d edits lab ope ke ownership mmunity. Kev good result me up. s! ONE techno nic carbon ( haracterizatio nt parameter mpacts how ed or relea does not ap going away s still find it p ans of norm oxicity and of the Yea r o r TOC in S o Volum Publish s. As usual, o hold off for t dly, we only d on our website of Columbu WWTP)! eir award by y 2016 meetin their success ned from pre dge along. Jo a supportive date with mo erators Kevin p of the lab an vin and Ryan ts and reso ology availab (TOC) is oft on work. TO r as the relat environmen ased into t ppear that TO anytime in t practical to u malizing orga bioavailabil r o lid Sampl e DN Joh me 27 Numbe ed September, 201 once we sit do the next editio distribute LabN e at: http://dn s’ DNR ng of s has evious ohn is City odern Neu nd do take olving ble ten OC ive ntal the OC the use nic lity The p meth and Unfor not m Subse differ what So let and w of TO The G Metho techn or fla (CO 2 ) which e s NR Secretary Ca hn Nehmer, and er 1 16 own and toss on. Rememb Notes via e-m nr.wi.gov/reg problem we h hods and pseu are routin rtunately, sev mesh with a equently w rentiate betw DNR program t’s take a loo whether or n OC in solid (se Gold Standa od 9060A nique followed ame ionizatio ) generated. h WI offers a athy Stepp with d Kevin Neu of t s ideas around ber to check y mail. You can gulations/labc have is that a udo-methods nely used veral common available opt we find o een client ac ms actually re k at which m not they are a ediment) sam ard - SW 846 offers a d by non-disp on measurem This is the o accreditation. h (from left) Ry the City of Colu d, we end up your e-mails b find the mos ert/info.html# wide array o have become for these nly used proc ions for acc urselves ha ccreditation de equire. ethods are w acceptable fo mples in Wisco 6 method 90 combustion persive infrare ment of carbo nly TOC tech Additionally yan Hoffman, umbus WWTP having a because in st current #tabX3. of modified e available analyses. cedures do reditation. aving to esires and widely used or analysis onsin. 060A. n/oxidation ed (NDIR) on dioxide nology for y, method

Upload: others

Post on 25-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

Isoa

TSt LboqMinaegp C

It’s time for asurplus of potorder to be mas well as rece

…and the a Wastewa

The laboratorSecretary Catthe Natural Re

Lab Director been a team eoperators andquick to shaManagement nstruments. Jand Ryan Hofexcellent worgreat pride problems whe

Congratulation

… Hammer Analysis of requested dlevels can beconcentratiotoxics will environment As far as wanalysis requnear future. TOC resultspollutants estimates ca

2016 Regi

Approved

nother editiontential articlesore environment editions o

award goesater Treatm

ry staff were thy Stepp at esources Boa

John Nehmeeffort from Dd has passed are credit anfor keeping John also creffman who takk for the comin getting

en they do co

ns, Columbus

rTime: only

total organduring site che an importan of TOC ibe adsorbe

t.

e can tell, ituests will be Data users

s as a measo that to

an be made.

istered Lab

Methods fo

n of LabNotess that we can

mentally friendof LabNotes o

s to… City oment Plant (W

presented ththe Februaryrd.

er says that ay 1. He learthat knowled

nd thanks athem up to dedits lab opeke ownershipmmunity. Kevgood result

me up.

s!

ONE techno

nic carbon (haracterizationt parametermpacts how ed or relea

does not apgoing away

s still find it pans of normoxicity and

of the Year

or TOC in So

VolumPublish

s. As usual, ohold off for t

dly, we only don our website

of ColumbuWWTP)!

eir award by y 2016 meetin

their successned from predge along. Joa supportive date with moerators Kevinp of the lab anvin and Ryants and reso

ology availab

(TOC) is ofton work. TOr as the relat

environmenased into t

ppear that TOanytime in t

practical to umalizing orga

bioavailabil

r

olid Sample

DNJoh

me 27 Numbeed September, 201

once we sit dothe next editiodistribute LabNe at: http://dn

s’

DNR ng of

s has evious ohn is

City odern Neu nd do take olving

ble

ten OC ive

ntal the

OC the use nic lity

The pmethand Unfornot mSubsedifferwhat So letand wof TO The GMethotechnor fla(CO2)which

es

NR Secretary Cahn Nehmer, and

er 1 16

own and tosson. RemembNotes via e-mnr.wi.gov/reg

problem we hhods and pseu

are routinrtunately, sevmesh with aequently wrentiate betwDNR program

t’s take a loowhether or nOC in solid (se

Gold Standaod 9060Anique followedame ionizatio) generated. h WI offers a

athy Stepp withd Kevin Neu of t

s ideas aroundber to check ymail. You cangulations/labc

have is that a udo-methods nely used veral commonavailable opt

we find oeen client acms actually re

k at which mnot they are aediment) sam

ard - SW 846offers a

d by non-dispon measurem

This is the oaccreditation.

h (from left) Rythe City of Colu

d, we end up your e-mails b find the mosert/info.html#

wide array ohave becomefor these

nly used procions for accurselves ha

ccreditation deequire.

ethods are wacceptable fo

mples in Wisco

6 method 90combustion

persive infrarement of carbo

nly TOC tech Additionally

yan Hoffman, umbus WWTP

having a because in st current #tabX3.

of modified e available

analyses. cedures do reditation. aving to esires and

widely used or analysis onsin.

060A. n/oxidation ed (NDIR) on dioxide nology for y, method

Page 2: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

9060A also offers itself as a recognized authoritative method based on it being an EPA document and it being one of the authoritative sources listed in NR 149 Appendix iii. Note that SW 846 9060 has been retired by the EPA and 9060A is the version that is currently acceptable for use. Although this method may not explicitly be written for solids it can easily be adapted to solids by weighing out a certain portion of sample and placing it in a boat instead of aliquoting a certain volume of sample. The Walkley-Black procedure. We’d call this a procedure, rather than a method, because it has been modified extensively over the years, and includes correction factors. It is over 50 years old and was written as a soil agronomy method used to determine “organic matter” –not TOC– in soils. The Walkley-Black method is a titrimetric procedure that changes from a dull green to a reddish brown color. Note that the endpoint can be very difficult to discern in samples that contain any natural color, particularly sediments laden with tannins or lignins. Besides the multitude of different versions of this procedure being currently utilized (can you say inconsistent analysis) the main problem is that titrimetry is not a TOC technology for which WDNR offers accreditation. Further, Walkley-Black is not recognized as an authoritative method by the EPA and it is not one of the authoritative sources listed in NR 149 Appendix iii. It is well documented that the Walkley-Black method is subject to interferences (chlorides and iron) and does not oxidize all organic carbon and is particularly poor for digesting elemental carbon forms. To overcome the incomplete digestion the method was later modified to include an extensive heating step during the sample digestion which most labs do not utilize. The “Lloyd Kahn” method. This is a method written by a quality assurance chemist for EPA Region II. It has never been sanctioned by the EPA and does not have any official EPA document number. And, in fact, it was originally developed for the determination of TOC in ocean sediments!

Inorganic carbon from carbonates and bicarbonates is removed by acid treatment. The organic compounds are decomposed by pyrolysis in the presence of oxygen or air. The carbon dioxide that is formed is determined by direct non-dispersive infrared detection (NDIR),

flame ionization gas chromatography (GC-FID) after catalytic conversion of the carbon dioxide to methane; or thermal conductivity gas chromatography (GC-TCD), after removal of water.

Lloyd-Kahn’s “procedure” offers several GC technique options for determination, which is not a TOC technology that WI offers accreditation for. It is not recognized as an authoritative method by the EPA or it would have been given an official method number and it is not one of the authoritative sources listed in NR 149 Appendix iii. On top of that, this “method” offers multiple versions or options of itself to users. There is no one official industry standard version of the Lloyd Kahn method recognized so it is hardly certain to even say that a single method exists. The bottom line is that the only accreditation Wisconsin offers for TOC in solid samples is the combustion/oxidation technology. There are many advantages to using this singular method for all TOC analyses in solids. • It is EPA acceptable • It is NR 149 acceptable Finally, using one method to generate TOC results provides consistency to the data users when multiple labs are used. Wisconsin data users have noted TOC results with an order of magnitude of difference in results when different TOC methods are utilized. CRITICAL CAVEAT: Keep in mind that just because our program does not certify TOC methods other than those using oxidation/combustion followed by IR – it does not mean that these alternate procedures cannot be used for agency projects. It just means that accreditation is not offered for them. Certain project sites may prefer other TOC methods for historical purposes, site specific interference purposes, or special data use purposes. That is fine if there is a project specific quality assurance project plan (QAPP) that outlines exactly what method is being performed – version and source - and exactly what elements of the method must be followed if all of the method procedures are not required. NR 149 has an allowance where the QAPP can supersede the requirements of the administrative code as long as they are clearly documented in the QAPP.

PT Provider factoid: The Wisconsin State lab of Hygiene provides PTs for most WI labs, followed closely by ERA and Phenova.

Page 3: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

Calculated versus actual phosphorus concentrations.

The relationship between phosphorus concentration and absorbance. Graphic courtesy of North Central Labs.

…pssst…it’s only linear to about 1 ppm!

Each year, hunters sight-in (re-calibrate) their rifles prior to deer season. You might call this a 3-point calibration: zero, 25 or 50, and 100 yards. For most of us who hunt woodlots or northern Wisconsin cedar swamps, this calibration is just fine. But what if this year, you’re taking that big trip out west to try your luck at elk or mule deer. Your calibration out to 100 yards isn’t going to work out so well in Big Sky Country where 300-plus yard shots are common. Your 30-06, sighted in at 100 yards, will drop about 12 inches at 300 yards. Best know your calibration range before you take that shot! While we don’t have gravity working against us, the same concept applies to total phosphorus. Due to the nature of the chemistry of colorimetric phosphorus analysis, instrument response becomes non-linear past about 1 ppm. If you calibrate up to 1 ppm and the absorbance of your sample is greater than the absorbance of your 1 mg/L standard, then your total phosphorus result will be biased low.

So, if you do not dilute your sample such that the absorbance is below that of your high standard (typically 1.0 ppm or less) you will under-report the actual concentration of phosphorus in your sample.

The more you go beyond the linear portion of the curve, the more inaccurate your results will become. This is important in reporting accurate and defensible compliance data. Many facilities measure the phosphorus in their influent to gauge the level of required phosphorus removal. If you do not sufficiently dilute your sample to within the linear range of the curve (as close to the middle as you can is the best for the most accurate results) you will be underestimating how much actual phosphorus is coming into your plant. This, in turn, could grossly underestimate the percent removal you are achieving. In summary, do not extend your calibration like you would for your rifle. Instead, bring your phosphorous target within range and DILUTE!

Are You Calibrating Your Total Phosphorus Within Range?

Page 4: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

Wfbs 1TOatyfat Bratin Bintaro Aevpa$ Aoo

We’ve selectfive for this abottom line smarter, not

1. PurchasThe chemistryOne or more—and diluted tthings from scyou. Let’s loofor BOD deteacid) requiresthese two com

Behind Door reagents oursalone costs abthings we neen a bit. Behind Door ndividual sterthe appropriata little over required per option costs u

And finally, equipment vevials of readyprepare 7-8 Ga pack of 12 $45, more tha

And now for own reagentsof making up

Time Time

Top 5 ine

It’s pretty significantWWTP opwear manoften the salawn maintecleaning, atasks as linof gamSubsequentoptions to your lab

testing. ed the top article. The is to work

t harder.

e Reagentsy testing that—often dry—to a specifiecratch can reok at just oneerminations. s purchase ompounds. Let

#1 we havselves. Purcbout $60/yeaed to do afte

#2, there isrile ampules te GGA soluti$40. Assumweek, that

under $100/ye

behind Doorendor you cay-to-use GGAGGA standards

vials. That’an enough for

the downsides. What’s theyour own sta& cost of repto dry & desi

efficiencies i

common knot percentaperators arny hats. Tame people denance, snownd even such

ning sports fiemes or tly, we can o

improve the

s…don’t makt you do req

—reagents areed volume. eally create a e example—th GGA (gluco

of dry chemict’s make a de

ve the optiochasing theser. Then therer that. But w

s the option containing exon. A pack o

ming one GGmeans the

ear.

r #3, from an obtain in. Each vial cs, at a cost o’s 84-96 GGAr a year’s wo

e to Door # e cost (in maandards/reagelacing reagenccate reagent

in the WWT

owledge that ge of smare forced

These folks adoing municipwplowing, streh unimaginabelds in advan

tournamenffer an array e efficiency

ke ‘em! quires reagene measured o

Making thebottle-neck f

he GGA reageose + glutamcals of each eal, shall we?

on making te two reagene’s all the othwe’ll get to th

of purchasixactly 6 mLs of 20 vials cosGA standard

sterile ampu

a routine ldividual 50-mcan be used

of about $45 fA standards forth of testing

1, making yoaterials & laboents? nts. ts.

TP Lab

a all to

are pal eet ble nce ts. of of

ts. out ese for ent mic

of

he nts her hat

ng of

sts is

ule

ab mL to

for for

g. 

our or)

Can yothat’s #2. Acosts reageneven Jay hain the points It just reagenfour sewater, and diltests…What a 2. BatBatchinsamplethe chwell fo Simplytotal pholdingPO4) dP everygiven pbe surthe samfor amimmedsuperindaily Ntestingask qu Then yonce amonthmonthreductmeansonly correct

Time to weTime to preTime to ensTime to autReagent traTime to docTime to re-

ou do all ththe differencAnd Door #3

25% less nts alone. need to con

as on his tabbox that Ca

s to on the f

makes good nts whenevereparate regesimply add

lute to the sp…not just BODare you waitin

tch samplesng samples es you analyzances of faili

or wastewater

y acid preservphosphorus ug time is 28 daily using a qry day. O-PO4

plant and is qre you are lo

ame units—as mmonia daily diate procesntendent to NH3 data. If g weekly or evuestions.

you can anaa week, once . Analyzing rather than ion in QC sa

s 40 chanceslead to motive action.

eigh out reageepare in solutsure that the toclave (best acking time. cument each -prepare befo

hat for underce in cost be3 offers a p

than the We don’t

nsider what ble or what’s arol Merrill floor .

sense to purr possible. Ients used to

one powder pecified volumD. ng for? 

s for nutriendecreases

ze, which cutng QC! This r nutrients.

ve samples foupon receipt days. Run quick test kit

4 tracks reallyquick & easy tooking at boths P, not as PO4although the

ss control. see if they a

f not, why nvery two wee

alyze ammone every other total P or 5 days a we

amples analys of exceedinore time sp

ents. tion. solution is vafor GGA reag

part of the pre solutions e

r $40/year? etween Doorsre-made opt

rchase qualityInstead of mprepare BODpillow or co

me. And it wo

nts the numbe

ts both your approach wo

or ammonia (back at the ortho-phosp

t instead of dy well with totto perform. (

th o-PO4 and O4!). Many fac

data is not c Check w

are actually not suggest deks. Don’t be

nia and Totalweek, or eveammonia jus

eek results in yzed! 40 QCng criteria, wpent taking

alid. gents).

rocess. expire.

Because s #1 and ion which

y prepared making the

D dilution oncentrate orks for all

r of QC time and

orks really

(NH3) and lab. The

phorus (o-doing total tal P for a Note: just total P in

cilities test critical for

with your using the doing the e afraid to

l P either en once a st once a a 20-fold

C samples which will

required

Page 5: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

IrSa 3Atc Cowsewpcef Ysrb YMm(

If you chooseremember NOSulfuric acid (actually char “

3. Stop conAre you genethem? Just control charts

Control chartsof statistical pwidgets, one specifications.excluded fromwidgets. Wprogram has charts, althoemployed to fall within req

Yes…there is simply go throreally use thebetter spent e

You must anMS/MSD) if method you (MS)/replicate

e to use this aOT to “pre-dos(H2SO4) is a “poly” sample

ntrol chartinerating QC sagoing througbut don’t rea

s were originaprocess contr

desires thos. Widgets

m the line. WeWe are produ

never requireough quality be certain ouirements.

some value tough the pacem….you are elsewhere.

nalyze matrixthe methodsuse does

es (DUP), the

approach andse” bottles wipowerful oxid

e bottles.

ng amples but ngh the motionally know why

ally developedrol. If one isse widgets tothat are ouell…we’re notucing data. ed the use of

control limour “widget”—

o Control Chaces to make t

wasting time

x spikes ands require thenot require

en consider n

re-use bottleith sulfuric acdant which c

not really usins to construy?

d as an elemes manufacturio meet certa

ut of spec at manufacturi The LabCe

f quality contmits must —QC samples

arts. But if ythem…but doe that could

replicates (em. But if t

matrix spikot preparing

es, id. an

ng uct

ent ng ain are ng ert rol be s—

ou n’t be

(or the kes or

analyzdoing requireMS andmatrix,does wof the Bottomproducunless addresperformnot a sampleresponyou anprovideregard 4. CoA num“probethem icolorimwastewfacilitieassociaswitchhave eby abo As ISEresultinprobe standathe comunicidistill. cannotcalibrayour o If you the (Total too. Twithdratechno BUT…dapplicSince yapplica

ing them. W“extra” QC, ie more effortd DUP sampl, but we are

when no matrLCS.

m line: You ce a researchyou have the

ss issues raisem optional Qset of contr

es are evaluanding to QC enalyze shoulde you with t

ding performa

olorimetry fmber of labses” (ion selein for HACH’

metric procedwater testinges that could ated with thing to colorimestimated thaout 40% over

E probes agng in calibratake to obta

ard?). Be awolorimetric teipal wastewat Also note

t use “pre-ations; you mwn calibration

are already acolorimetry P) you will s

That’s becausaw from

ology accredit

don’t forget tcation beforyou would beation and a ne

While some in most casest (and cost) wles can provide most intererix can be bla

get paid to p project! Do e need, the tied by them. C we can citerol limits aga

ated or if theexceedances. d be suited fthe feedback

ance.

for Ammonias have tossective electro’s Ammonia Tdure, which hg. But thealso benefit

his change metric ammonat making ther the ISE meth

ge their respation issues ain a stable rware though,est is only ster effluent uthat despite

programmed”must preparens.

accredited fotechnology

save some $$se a lab could

the ISEtation.

that you MUre switchine switching tew PT (by co

might place s extra QC iswith very littlde informatioested in howamed. That i

provide RESUNOT analyze

ime, and the Because if ye the facility ainst which

e facility is no The QC sam

for your operk you –and w

a ed out their des, ISE) anTest’nTube (Thas been appere are mafrom the timand should

nia (TNT methe switch reduhod.

ponse times (how long dreading for a, that, like esuitable for unless the labe vendor cla” e

r y $ d E

ST submit ang and doingtechnologies, lorimetry) is r

value of s going to le benefit.

on about a w your lab is the role

LTS…NOT e extra QC energy to

you opt to if there is these QC

ot properly mples that ration and we– need

annoying nd traded TNT) Plus proved for any other me savings

consider hod). We uces labor

decrease does your a 0.2 ppm electrodes, domestic,

b plans to aims, you

a revised g testing. a revised

required.

Page 6: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

Ps 5IyaNpoywkdlarc Mavmrvaa Mmbde Bpa

Hgainpthrwttph

Please call answitch; we ca

5. Use MecIt’s long pastyour multitudea couple of Not only is precision likelof the “old schyou eliminatewashing andknowing full drying (espeabs have theright by a mcontaminated

Many WWTP and these vialvery small vomechanical pirequired, althvariable volumabout $280-$adjustable pip Mechanical pmake the prebreeze, as adelivered accueliminate or a

Bottom linepipets is a smand precision.

…Got phos

How do labglassware aadequately clnterest to thepains to cleanto reduce thehot tap waterrinse with dilwater* and athey are confito prevent phosphorus. have to admit

Controllin

nd check in n help.

chanical pipt time to trae of glass pipmechanical the accurac

ly better thahool” approace all of thed drying

well that, cially when e pipet dryinmain sink), g.

labs are usils absolutely rolumes, whichipets. Thereough a lab c

me pipets wh$400 each. Apet are all mo

ipets are quparation of cany microliteurately. In adt least minim

e: Purchasinmall price to .

sphate add

boratories end bulk ceaned and ne sample? Mn their sample risk of contar and non-pholute hydroch little distilledident they ha

contamina Even the “Fot he was wr-w

g (??) conta

with us befo

pets ade in

pets for pipets.

cy and an that ch, but pipet time—while many

g rack glass pipets

ing Hach Tesrequire accurah really reque’s certainly acan make dohich come at A 0.1-1 mL ast labs need.

uick and eascalibration curer volume nddition, singleize contamina

ng a couple pay for effici

itives?

ensure sampcomposite cnot contributiMost laboratole containers amination. Tosphate deteloric acid fold water. Witave done everation, partonz” from Hapwrrr-wrong in

amination in

ore making t

can easily

stNTubeTM kiacy when usiires the use a capital outlo with only tw

a price tag and a 1-10 m

sy to use, arve standardseeded can e-use pipet tiation.

of mechaniciency, accura

ple containecontainers aing analytes ories take gre

and glasswaThey wash wergent and thlowed by *tth all this carrything possibticularly froppy Days mig

n believing tha

n the Lab

the

be

ts, ng of ay wo of

mL

nd s a be ips

cal acy

rs, are of

eat are ith en

tap re, ble om ght at.

Laborapotent Many wcommuorthop(unlessto seqAveraglevels suppliePO4 wto 1 ppup to uncomphosphtap wathey gcontamcleanineven a These bottlesprecaurinse wwash toccasiophosphthe saline hethen sThis mhigh omay bfees. additioat the by the The sithas a coppersamplecan cacases of cont What s Ch

suis ortaninc

atories often tial sources of

wastewater lunity water

phosphate or s you’re Flinuester iron a

ge feed rates(PO4) in

es range fromwhich translatepm as P. Ho5 ppm PO4 (t

mmon. So a lahorus only to ater is used to to great eff

minant only tng. To makeaware this is h

same labs ths and glasutions to cleawith tap watthe compositonal basis. Ihate, again thmples duringere is if the csample phospmeans a facilion their discbe paying mo

Other costsonal treatmen

wastewater municipality

tuation can bdischarge l

r can build er pump tubinause elevated facilities coutributions from

steps can be t

heck with thepply is treatebeing added thophosphate

nd what conceclude names s

fail to recogf contaminatio

laboratories asupply ma

polyphosphant, Michigan) and manganes for phosphatreated wa

m 1 to 3 ppmes to about 0

owever, levelsthat’s about ab goes to gradd it back i

to rinse glassfort to removto add it bace matters wohappening.

hat take greassware raren their compoter only on ate containers If the water hey are likely

g the samplingcity water is tphorus levelsity may be reharge monitoore than theis are incurrednt chemicals ttreatment faitself!

be further comimit for metup in the

ng and sampl metals levelsld violate dism the samplin

taken to deal

e water utilited with phosp to the watee or a blendeentrations. Csuch as Aqua

gnize there on.

are unaware ay be treate to control or

ese. ate

ater as 0.3 s of 1.6 ppm as Preat lengths tn the rinsing

sware. In othve the phosphck in the finarse, most lab

at care to wasely take thosite containea daily basis with detergesupply is tre

y adding phosg process. Thtreated with ps may be biaeporting resuoring report ir fair share d due to theto remove phacility, that w

mplicated if ttals. Metals

composite ler lines whics in samples.scharge limitsng process.

l with these is

ty to see if tphate. Find er (i.e., polyped phosphateCommon prodaMag or Aqua

are other

that their ated with

corrosion

P) are not to remove process if her words horus as a l steps of

bs are not

sh sample he same ers. Most and only

ent on an eated with sphorus to he bottom phosphate ased high. ults biased

and they of NR101

e need for hosphorus

was added

the facility s such as container, h, in turn, In some s because

ssues?

the water out what

phosphate, e mixture) ducts used Dene.

Page 7: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

If the water utility adds phosphate, consider treating the water used for glassware and sample containers with reverse osmosis followed by anion exchange.

Consider purchasing a laboratory grade dishwasher for glassware and sample container cleaning. Most washers designed for laboratory use are equipped with a pump to allow the laboratory to feed the washer with water that has been treated to remove phosphate. Lab grade dishwashers can also be setup to include a wash cycle using a mild acid such as sulfamic or citric acid. Joe Panek from the Bristol Wastewater Treatment Plant has successfully used this approach for many years. He installed a 20 gallon polyethylene reservoir which he feeds with deionized water. The washer draws all water used for washing and rinsing from this reservoir.

If hand washing, use distilled or deionized (anion and cation exchange) treated water for washing and rinsing.

Instead of washing the sampler carboys consider using a food grade polyethylene bag as a liner for carboys. Mike Suha from the City of Appleton Wastewater Treatment Facility uses a relatively inexpensive food grade polyethylene bag as a liner. Mike says they cost $0.15 each so he has them changed daily. Contact the LabCert program for more information.

If a facility has a discharge permit for metals and requires monthly sampling, consider using the food grade polyethylene bag and changing the sampler line and pump tubing immediately before sampling for metals. Sam Warp and Ted Bratton from the City of Marshfield Wastewater Utility began using Clavies plastic bags as carboy liners in 2014 to address copper and phosphorus contamination issues. They found copper levels in their effluent samples decreased significantly after switching to the carboy liners. They determined prior samples were elevated due to sample contamination during the sampling process.

Finally, a word about acid washing. Don’t go crazy using strong acid to wash glassware and sample containers. Use dilute hydrochloric acid; limit it to 1%. DO NOT USE stronger acid. Remember, strong acids pose an increased safety hazard and do not improve cleaning efficiency. When it comes to acid, less is more.

From little known secret sources of contamination (phosphates used in the water supply) to carboy liners

to using too much acid, there are many things that detract from an operator’s ability to do the job well. Always feel free to contact your auditor for assistance as needed. …Not everything goes!

They say that a picture tells 1000 words, but when it comes to approved methods to be used for compliance testing, pictures don’t cut it. In their desire to be customer friendly, Hach has developed quick “picture” versions of its methods. Unfortunately, these “picture” methods are NOT approved for compliance. You must actually have (and use) a paper or electronic copy of an approved Hach Method in EPA format when using and citing Hach Methods for any compliance monitoring. The “EPA Format” method version of methods can be found on the Hach website or contact a Hach representative. The Hach Co. has developed a number of test kit methods that have been approved outright (as standalone methods) by the EPA. These EPA approved methods will appear in 40 CFR Parts 136 [wastewater] or 141 [drinking water]. These methods are acceptable for compliance testing under the programs that approved them. Other Hach (and similar vendors’ test kits) methods have been deemed “equivalent” to approved methods under those federal programs.

Considerations when using Hach methodologies

Page 8: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

A listing of Hach EPA compliant methods, by program, is available at: http://www.hach.com/cms/documents/pdf/EPA/HachEPACompliantMethods.pdf

A. For drinking water you may only use methods that appear in 40 CFR Part 141 or the methods that are “EPA-approved” for the Drinking Water program.

B. For all other environmental programs you may use methods that are “Approved”, “Accepted” or “Equivalent”.

C. If you’re unsure…contact your auditor or the program general contact.

There are a number of other considerations when using Hach methods: What method should I report with my results? For wastewater compliance monitoring (WPDES) labs must report the authoritative method (the approved reference method listed in the Hach method). Do not cite the Hach method unless it is approved as a standalone method in the Federal Register. The reference method is provided in the table on the [http://www.hach.com/cms/documents/pdf/EPA/HachEPACompliantMethods.pdf] link. For example, if a lab is using the TNT Plus 843, Hach Method 10210 for Total Phosphorus, the method to be reported is EPA 365.1 [automated] or EPA 365.3 [manual]. Note that this approach will also help when reporting PT sample results.

How do I indicate I’m using a Hach method for testing if my reference is something else? If you are using a Hach Method, that information must be included in your SOP. There are method numbers and product numbers for Hach. For instance, for Total Phosphorus the product numbers are TNT843, TNT844, and TNT845 but the Hach Method number is 10210  for all of these. Use the Hach Method number in your SOP, but also be sure to include the product number used under the consumables section of your SOP. What quality control is required? Labs must perform the required quality control samples listed in the approved reference method – not what is in the Hach method. If there are no required QC samples in the reference method then defer to NR 149 for required QC. My vendor says I can use the pre-programmed calibration on my DR-xxx. Is that true? Sorry, but no. No matter what any vendor representative or method may proclaim, WI does not allow the use of pre-programmed calibration curves. Each lab must generate their own calibration curve, at the frequency required by NR 149, using their own equipment, standards, reagents, and lab conditions.

My vendor says I never have to calibrate my new LDO probe for BOD. Is that true? Again, no. This is not true in Wisconsin. DO/BOD probes must be calibrated daily.

Is there anything else I need to be concerned about? Even some of the allowable Hach versions have errors and here are TWO common ones that you need to be aware of.

A. Total Phosphorus method 10210 contains two clear errors. Samples must be digested for 30 minutes

at 150 ºC at a minimum. (Many versions indicate to heat for 60 minutes at 100 ºC).

Samples must be neutralized before digesting. (All versions indicate that a pH between 2 and 10 is acceptable).

B. Ammonia by method 10205 contains an error as well. Samples must be preserved with sulfuric

acid --not hydrochloric acid (HCl), as many Hach versions indicate).

Page 9: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

…is ACME Labs certified for tetramethyltoast? Many regulatory agencies drill down and certify to the analyte level. We find these Scopes of Accreditation to be decidedly user UNfriendly. The average client procuring lab services would be hard pressed to wade through scores of analytes for different regulatory programs and analytical methods to determine that a lab is capable of providing its testing needs. While the Wisconsin Laboratory Certification and Registration Program can provide accreditation on the analyte level for those analytes we offer accreditation for; we also provide an array of discrete “Analyte Group” offerings in the aqueous and solid matrices to make your life easier. These offerings are as follows:

• PAH group (lists for GC, GCMS, & HPLC) • BNA group (GCMS) • VOC group (lists for GC & GCMS) • Organochlorine Pesticides group (lists for GC &

GCMS) • PCB as Aroclors group (lists for GC & GCMS) • PCB Congeners group (lists for GC, GCMS, &

HRMS) • Dioxin & Furans group (lists for GCMS, & HRMS)

The benefits of utilizing the analyte group accreditation, instead of individual analytes are: • Your certification scope is more concise and easier

to read • Proficiency testing (PT) samples are not required

for each analyte in the group – instead we only require the analysis of a standard (VOC/BNA/PAH/ Organochlorine pesticide/PCB/Dioxins-Furans] PT sample from an approved Provider. Note, however, that: Our program does not assess PTs as the

NELAC program does,

Our program has established minimum numbers of analytes which must have non-zero assigned values,

Only analytes with non-zero assigned values “count”,

At least 80% of non-zero analytes must have acceptable results,

False positive and false negatives will adversely affect your score.

• Less PT requirements means less money and time spent on the annual requirement. While certifying by analyte groups is a great bonus for labs, labs need to remember that there is a specific list of analytes associated with each analyte group and that those are the only analytes you are certified for – not every possible analyte that can fall under the description of a PAH, BNA, VOC, etc. analyte. So how does a lab know which analytes fall under each analyte group? We provide a list of those analytes on our website (http://dnr.wi.gov/regulations/labcert/info.html#tabx2) Each analyte group that we offer accreditation for is listed along with the technologies that are associated with them. Click on any of those groups and a pdf that is downloadable is available that lists all of the analytes covered by the “analyte group” accreditation. So when a laboratory is checking to verify proper WI accreditations they need to review these analyte group lists versus their project lists to make sure they are not performing any work without certification.

Analyte Groups – a flexible option

Page 10: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

ToAp EP

HarTfe(aat TaprN W Ws

…Hint: the

The Land Apoften requiresAmmonium performed.

Examples of Permits:

However, theare actually requirement sTotal! Simplyfor ammoniumequilibrium be(NH4

+). Ammat pHs over 1ammonia by Ito a pH of at l

The Wastewaare working permits suchrequirement tN. Revised fo

What do we d

When a requsludge/biosoli

Ammonium

ey’re really

plication sects that the nu(NH4-N) To

how this c

ese requests a long-igno

should read Ny stated, them. Ammonietween amm

monia (NH3) i0. This is theISE requires aleast 11.

ter Program on revising

h that updo perform NH

orms will even

do in the mea

uest for NH4

ds sample, t

m? Or Amm

the same th

tion of Wastutrient paramotal” analysi

can appear

and lists, asored error. NH3-N (Nitrogre is no test ia -N exists

monia (NH3) as a gas and e reason whyaddition of so

is aware of ththis section

ated permitH3-N analysis ntually be mad

ntime…?

4-N analysis the test tha

monia? Whic

hing!

ewater Permmeter “Nitroge

s testing

in Wastewat

king for NH4

Instead, tgen, Ammonthat measurin a perpetu

and ammoniuis predomina

y the analysis dium hydroxi

his mistake an of municipts reflect tinstead of NHde available.

is made on t needs to

ch is it?

mits en, be

ter

4-N the ia) res ual um ant of de

nd pal the H4-

a be

performof wha Keep in

• Tfod

• OdeNboba

• NwpeIS

• Nw

• FmmbeinN

• OApeNac

Bottom(NH4+reques …Al

Back iFreon replacethe exExtract(fats, oretired But th“Silica “SGT-Hand SG

F.O

med is NH3-Nat the permit

n mind the foThere are no or ammoniuifferentiate be

Once the etermined, t

NH4-N can beoth are alwased on the s

NH3-N is prevawe adjust theermeable meSE.

NH4-N is prevawe preserve saurthermore,

measuring Nmeasure the sefore analytic

ncreased untiNH3-N. Over time the Application Reermits and c

NH3-N but reccomplished

m line: yo+)…period. sted, the inten

phabet sou

n 1997, the extraction

ed the ozonextraction soltable Materiaoils, and grea

d in favor of h

here’s a twistGel Treated

HEM”. MakeGT-HEM are li

O.G. advisory

N and reportemay say.

ollowing test methods

um (NH4-N) etween NH3-Ntotal NH3-

the concentre estimated bays present,sample pH. alent when p

e pH to at leaembrane for a

alent when pamples using all of the a

NH3-N (total sum of “NH3

cal measureml all NH4-N p

DNR will worequirements change the equests for by performing

ou can’t meIf analysis

ntion is for am

up only furth

EPA made cprocedure foe-depleting Flvent. Thusal”, or HEM. ase) and oil &hexane extrac

t. There’s N-Hexane Ex

e no mistakeisted under “o

y: H.E.M. v

ed as NH3-N r

s that directly– and no

N and NH4-N.N concentrrations of Nbased on sam the ratio j

pH > 8.5, whiast 11 and uanalysis of am

pH < 8.5, whiacid.

approved me ammonia)

3-N + NH4-N”ment occurs present is con

rk on revisingsection of

NH4-N requirNH4-N now

g NH3-N.

easure for as of ammommonia.

her muddle

hanges to thor oil & greFreon with hs was born

The terms& grease are ectable materia

also this thxtractable Mae, although boil & grease”

vs. SGT-HEM

regardless

y measure one that

ration is H3-N and

mple pH – ust shifts

ich is why use a gas-mmonia by

ich is why

ethods for actually

” because the pH is

nverted to

g the Land municipal

rement to w can be

mmonium onium is

es things

he original ease and hexane as

“Hexane s “F.O.G.” effectively al (HEM).

ing called aterial”, or both HEM in federal

M

Page 11: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

r(

OmpleScH IcHcCCSwHsHrp Stpsotw FgisaHmovotin

rule (40 CFR (NR 219), the

Oil and greasematerial. Thepolar fractioneaving the noSGT is an optcan be perfoHEM. The two

In our checkincode we haveHEM should bcategorical staCFR 465) andCFR 442) reqSGT-HEM canwastewater pHEM. If youshould verify HEM as oil &results and eparameter cod

So…generally the analysis opollutant knosituations wheof SGT-HEM athe source owastewater pl

For example, grease impacts a restauranand greasesHowever, if metals finishinother manufvolumes of luof SGT-HEM ctesting is monvestigative—

Part 136) andse are two ve

e is made up e silica gel tren (natural oilon-polar (pettion in the meormed and ro are differen

ng with DNR e found nothbe reported tandards (coil d transportatuire testing fn be used foretreatment

u are reportthat you sho

& grease, or each must bede.

speaking, peof HEM as a mown as oil &ere you may as a process of oils and lant.

if you suspecting your WWt (i.e., the off), then HEyou suspect ng plant, autfacturing op

ubricants or ccould help idore properly —not complian

d the Wisconery different a

of both polareatment (SGTs and fats) roleum oils). ethod that doresults repornt parameters

staff and theing that indicto the DNR. coating and cion equipmenfor petroleumor this testinprograms maing SGT-HEMould be. Nev

HEM. Thee reported w

ermits are wrmeasure of th& grease. Tbe able to ucontrol approgreases com

ct that the soWTP or the cofending mate

EM is the the source

to service staperation thacutting oils, thdentify the solabelled proc

nce monitorin

nsin counterpaanimals.

r and non-poT) removes tof the samp Just becau

oes not meanted instead

s.

e administraticates that SG Some Fedecan making (nt cleaning (

m hydrocarbonng. Also, somay require SGM results, yver report SGy are differe

with a differe

ritten to requhe conventionThere may

use the analyoach to identming into yo

ource of oil allection systerial is polar fabest analysto be a loc

ation, or somat uses larhen an analyource. But thcess control ng.

art

lar he ple use n it

of

ive GT-ral 40 40 ns. me GT-ou

GT-ent ent

ire nal be sis tify our

nd m, ats sis. cal me rge sis his or

SGT-Hknownnow knof TPHis presrequirecatego Bottomrequiremay hebe biaform o If youraqueouapplicatherefo EnsuremethoparticuincreasTo ohttps://d

…It’s

Did yolaboratresponrejectiowater not me– upon Our aunoticedstruggold quepay thecertific When answehandlewishes

Hexa

Reje

EM providesn as “total petnown as “non

H (now SGT–sently requireements undeory at 40 CFR

m Line: Foed for permitelp you meet

ased low andof grease bloc

r lab is certifus matrix, able to “Heore WPDES sa

e that any sads are met

ular concern ise the samplebtain a pddocs.legis.wiscon

s a lab’s res

u know that itory’s nsibility for on of drinkingsamples – thaeet specific crn sample rece

uditors have d that laboratle with the agestion “Who de bills or the

cation?”

it comes to dr is easy - dri

ed according ts.

avalent chro

ection of Dri

s a measuretroleum hydron-polar materHEM or ‘‘noned in the moer the Coil 465.03(c).

or 99+% of t compliance. t a permit limd karma will cks in your co

fied for Hexavkeep in miexavalent Camples requir

ample handlinwhen requi

if the samplee hold time todf copy ofnsin.gov/code/ad

sponsibility

it is a

g at do riteria eipt?

tories ge do we listen tregulatory bo

drinking waterinking water sto law – rega

omium rem

inking Wate

e of what isocarbons” (TPrial (NPM). M-polar materi

onitoring and Coating poin

labs, HEM a Analysis of

mit, but your rmanifest its

llections syste

valent Chromind that NR

Chromium, dre filtering.

ng requiremered. This m

e will be madeo 28 days. f NR 219, dmin_code/nr/20

y

to – our clientody that grant

r, for Wisconssamples mustrdless of the

minder

er Samples

s formerly PH), but is Monitoring ial;’’ NPM) reporting

nt source

analysis is SGT-HEM

results will elf in the em!

mium in an R 219 is dissolved”,

nts in the may be of

e basic to

go to: 00/219.pdf.

ts who ts us

sin, that t be client’s

Page 12: Volume 27 Number 1dnr.wi.gov/regulations/labCert/documents/LN2016A/LN2016A.pdf · sample digestion which most labs do not utilize. The “Lloyd Kahn” method. ... The bottom line

This document is intended solely as guidance and does not include any mandatory requirements except where requirements found in statute or administrative rule are referenced. This guidance does not establish or affect legal rights or obligations and is not finally determinative of any of the issues addressed. This guidance

does not create any rights enforceable by any party in litigation with the State of Wisconsin or the Department of Natural Resources. Any regulatory decisions made by the Department of Natural Resources in any manner addressed by this guidance will be made by applying the governing statutes and administrative rules

to the relevant facts.

NR 149 indicates the following

NR 149.46 (4) SAMPLE PRESERVATION AND HOLDING TIME. (a) Laboratories shall follow the sample preservation procedures and holding times required by state and federal regulations. NR 149.46 (2) SAMPLE ACCEPTANCE POLICY. (a) The laboratory shall have and follow a written policy that clearly outlines the conditions under which samples will be accepted or rejected for analysis, or under which associated reported results will be qualified.

1. Drinking water samples received beyond holding time, improperly preserved, in inappropriate containers or showing evidence that they have not been collected according to approved or accepted protocols shall be rejected for analysis, unless the laboratory can document that it has been instructed by the client to proceed with analyses, and all associated results are accompanied by a disclaimer attesting that results may not be used to determine or evaluate compliance with the safe drinking water act.

So the laboratory must have a written sample acceptance policy and include in that policy the criteria the laboratory is using to determine whether drinking water samples will be rejected or accepted. This is a decision that the laboratory makes based on the law – neither the client nor the water system can indicate that a rejected sample is acceptable for compliance analysis. The following elements, at a minimum, must be assessed and addressed in the sample acceptance policy: improper temperature preservation, improper chemical preservation, improper containers, expired holding time, and unsecure receipt. The sample acceptance policy must also discuss the action the laboratory takes for communicating the rejected samples to the client and how this communication is documented.

The client can request that the rejected samples be analyzed by the laboratory for informational purposes

if that instruction is received in writing and if the results are qualified with a “not

to be used for compliance purposes” qualifier.

If it is discovered that the laboratory is not rejecting drinking water samples appropriately and they are not qualifying the results appropriately the consequence is a likely Notice of Non-compliance enforcement action from Wisconsin. Repeat offenses will result in escalation to a Notice of Violation. If any laboratory would like assistance in explaining this requirement to a client, contact us and we would be glad to intervene. We need only look to Flint, Michigan to be reminded of our collective responsibility in protecting public health.

LabNotes Newsletter of the Laboratory Certification Program

LabNotes is published by the Wisconsin DNR Laboratory Certification and Registration Program.

Bureau of Science Services

(608) 267-9753

Steve Geis, Chief Environmental Science Services Section

(608) 266-0245

Rick Mealy LabNotes Editor (608) 264-6006