victaulic pressure valves series 867-400, 867-4uf, … · 200 12 2 – 11.5 867-7uf 2 – 6 200 350...

19
victaulic.com 30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. 867–400 867–4UF 867–459 867–7UL 867–7UF 867–759 867-42T 867-43T 1.0 PRODUCT DESCRIPTION Function 867–400: Pilot Operated, Pressure Reducing Valve 867–4UF: Pilot Operated, Pressure Relief Valve 867–459: Pilot Operated, Pressure Relief Valve with Electric Override 867–7UL: Pilot Operated, Pressure Reducing Valve 867–7UF: Pilot Operated, Pressure Relief Valve 867–759: Pilot Operated, Pressure Relief Valve with Electric Override • 867-42T: Pilot Operated, Pressure Reducing Valve • 867-43T: Pilot Operated, Pressure Relief Valve Operating Temperature by Material Standard: Natural Rubber: 122ºF/50ºC Optional: Nitrile/NBR: 176ºF/80ºC Optional: EPDM: 194ºF/90ºC End Connections • Grooved (OGS) • Flanged • Threaded Typical Applications • Fire Protection Pump Rooms • Floor Control Assemblies Codes and Requirements • NFPA 13 • NFPA 14 • NFPA 20 • NFPA 25 Victaulic ® Pressure Valves Series 867-400, 867-4UF, 867-459, 867-7UL, 867-7UF, 867-759, 867-42T, 867-43T 30.93 1 System No. Location Submitted By Date Spec Section Paragraph Approved Date

Upload: doquynh

Post on 11-Sep-2018

278 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

victaulic.com 30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT.

867–400 867–4UF 867–459 867–7UL 867–7UF 867–759 867-42T 867-43T

1.0 PRODUCT DESCRIPTION

Function• 867–400: Pilot Operated, Pressure Reducing Valve

• 867–4UF: Pilot Operated, Pressure Relief Valve

• 867–459: Pilot Operated, Pressure Relief Valve with Electric Override

• 867–7UL: Pilot Operated, Pressure Reducing Valve

• 867–7UF: Pilot Operated, Pressure Relief Valve

• 867–759: Pilot Operated, Pressure Relief Valve with Electric Override

• 867-42T: Pilot Operated, Pressure Reducing Valve

• 867-43T: Pilot Operated, Pressure Relief Valve

Operating Temperature by Material• Standard: Natural Rubber: 122ºF/50ºC

• Optional: Nitrile/NBR: 176ºF/80ºC

• Optional: EPDM: 194ºF/90ºC

End Connections• Grooved (OGS)

• Flanged

• Threaded

Typical Applications• Fire Protection Pump Rooms

• Floor Control Assemblies

Codes and Requirements • NFPA 13

• NFPA 14

• NFPA 20

• NFPA 25

Victaulic® Pressure ValvesSeries 867-400, 867-4UF, 867-459, 867-7UL, 867-7UF, 867-759, 867-42T, 867-43T 30.93

1

System No. Location

Submitted By Date

Spec Section Paragraph

Approved Date

Page 2: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

1.1 PRODUCT DESCRIPTION

Available Sizes, Pressure Ratings and Agency Approvals3

Product Configuration

Nominal Size Range FM Approval UL Listed Pilot Set Range

inches mm

psi bar

psi bar

psi bar

867-4UF2 – 6 175 175 30 – 175

50 – 150 12 12 2 – 12

867-7UL

2 – 6 NO FM APPROVAL

300 30 – 165

50 – 150 21 2 – 11.5

8NO FM APPROVAL

175 30 – 165

200 12 2 – 11.5

867-7UF

2 – 6 200 350 30 – 175

50 – 150 14 24 2 – 12

8 200 175 30 – 175

200 14 12 2 – 12

Product Configuration

Nominal Size Range FM Approval UL Listed

inches mm

psi bar

psi bar

Threaded

Grooved (OGS), Flanged ANSI

Class 300

Flanged ANSI

Class 150

Grooved (OGS), Flanged ANSI

Class 300

Flanged ANSI

Class 150

Rating Pilot Range Rating Pilot

Range Rating Pilot Range Rating Pilot

Range Rating Pilot Range

867-42T2

1 ½ 365 30 – 175 365 30 – 175 235 30 – 175 – – – –

40 25 2 – 12 25 2 – 12 16 2 – 12

2, 2 ½ – –

365 30 – 175 235 30 – 175 – – – –

50, - 25 2 – 12 16 2 – 12

3 – 8 – –

365 30 – 175 235 30 – 175 365 60 – 175 250 60 – 175

80 – 200 25 2 – 12 16 2 – 12 25 4 – 12 17 4 – 12

101

– – 300 30 – 175 235 30 – 175 300 60 – 175 250 60 – 175

250 21 2 – 12 16 2 – 12 21 4 – 12 17 4 – 12

867-43T

1 ½ – 2, 2 ½ – –

365 125 – 365 235 60 – 235 – – – –

40 , 50, - 25 9 – 25 16 4 – 16

3 – 8 – –

365 125 – 365 235 60 – 235 365 125 – 365 – –

80 – 200 25 9 – 25 16 4 – 16 25 9 – 25

101

– – 300 125 – 300 235 60 – 235 365 125 – 365

– – 250 21 9 – 21 16 4 – 16 25 9 – 25

1 10" (250) is only available as Class 300 Flange at this time 2 Max recommended pressure differential: 175 psi/12 Bar when normal inlet operation pressure is below 330 psi/23 Bar Max recommended pressure differential: 200 psi/4 Bar when normal inlet operation pressure is above 330 psi/23 Bar 3 Valve body material may change listing or approval. See Victaulic for details.

Available Sizes and Manufacturer's Pressure Rating - See Section 2.0 Certifications/Listings

Product Configuration

Nominal Size Range

Manufacturer's Pressure Rating Pilot Set Range

inches mm

psi bar

psi bar

867-4002 – 12 250 30 – 165

50 – 300 17 2 – 11.5

867-4592 – 12 175 30 – 175

50 – 300 12 2 – 12

867-7591.5 – 16 200 30 – 175

40 – 400 14 2 – 12

2

victaulic.com

Page 3: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

1.2 PRODUCT DESCRIPTION

Available Sizes by Material and End Connection

Body Material Ductile Iron Body Cast Steel & Stainless Steel Ni-Al Bronze Body

Valve Connection Grooved Flanged ANSI B16.42 Threaded Flanged ANSI B16.5 Threaded Flanged ANSI B16.24

Valve Configuration

Grooved

Flanged ANSI

Class 150

Flanged ANSI

Class 300 NPT / BSP

Flanged ANSI

Class 150

Flanged ANSI

Class 300 NPT / BSP

Flanged ANSI

Class 150

Flanged ANSI

Class 300

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

867-400 867-4UF 867-459

2, 3, 4, 6, 8 2 – 12–

2 2 – 12–

2 2 – 12–

50, 80, 100, 150, 200 50 – 300 50 50 – 300 50 50 – 300

867-7UL 867-7UF 867-759

1 ½ – 8 1 ½ – 16 2 – 6 2, 2½, 3 2 – 8 2 – 6 2, 2½, 3 2 – 8 2 – 6

40 – 200 40 – 400 50 – 150 50, 65, 80 50 – 200 50 – 150 50, 65, 80 50 – 200 50 – 150

867-42T 867-43T

1 ½ – 8 1 ½ – 10 1 ½ – 10 1 ½

– – – – –40 – 200 40 – 250 40 – 250 40

2.0 CERTIFICATION/LISTINGS

NOTES• Refer to Available Sizes/Pressure Ratings Table in section 1.0 for specific units and materials.

• Series 867-400, 867-459 and 867-759 are not listed or approved by FM or UL.

3

victaulic.com

Page 4: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

3.0 SPECIFICATIONS - MATERIAL

Series 867-400, 867-4UF, 867-459 Body Style

Cover: (specify choice)

Standard: Ductile Iron ASTM A536 65–45–12

Optional: Cast Steel ASTM A216 Grade WCB (coated)

Optional: Nickel Aluminum Bronze ASTM B148 C95800

Optional: Stainless Steel 316 ASTM A351 Grade CF8M

Valve Body: (specify choice)

Standard: Ductile Iron ASTM A536 65–45–12

Optional: Cast Steel ASTM A216 Grade WCB (coated)

Optional: Nickel Aluminum Bronze ASTM B148 C95800

Optional: Stainless Steel 316 ASTM A351 Grade CF8M

Elastomeric Assembly: (specify choice)

Standard: NR, Polyamide fabric reinforced Polyisoprene

Optional: NBR, Polyamide fabric reinforced Nitrile (Buna -N)

Optional: EPDM, Polyamide fabric reinforced Ethylene-Propylene

External Bolts/Nuts: Stainless Steel 316 ASTM A320 Grade B8F

Coating: (specify choice)

Standard: Electrostatic Powder Coating Polyester

Optional: High Build Epoxy Fusion-Bonded with UV Protection, Anti-Corrosion

Valve Body

External Bolts/Nuts

Cover

Coating

Elastomeric Assembly

4

victaulic.com

Page 5: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

Cover: (specify choice)

Standard: Ductile Iron ASTM A536 65–45–12

Optional: Cast Steel ASTM A216 Grade WCB (coated)

Optional: Nickel Aluminum Bronze ASTM B148 C95800

Optional: Stainless Steel 316 ASTM A351 Grade CF8M

Cover Bolt: (specify choice)

Standard: Zinc Plated Steel

Optional: Stainless Steel 316 ASTM A320 Grade B8F

Cover Nut: (specify choice)

Standard: Zinc Plated Steel

Optional: Stainless Steel 316 ASTM A320 Grade B8F

Separation Partition: (specify choice)

Standard: Ductile Iron ASTM A536 65–45–12

Optional: Cast Steel ASTM A216 Grade WCB (coated)

Optional: Nickel Aluminum Bronze ASTM B148 C95800

Optional: Stainless Steel 316 ASTM A351 Grade CF8M

Stud: (specify choice)

Standard: Zinc Plated Steel

Optional: Stainless Steel 316 ASTM A320 Grade B8F

Stud Nut: (specify choice)

Standard: Zinc Plated Steel

Optional: Stainless Steel 316 ASTM A320 Grade B8F

Valve Body: (specify choice)

Standard: Ductile Iron ASTM A536 65–45–12

Optional: Cast Steel ASTM A216 Grade WCB (coated)

Optional: Nickel Aluminum Bronze ASTM B148 C95800

Optional: Stainless Steel 316 ASTM A351 Grade CF8M

Spring: Stainless Steel 302

Removable Seat: Stainless Steel 304 ASTM A743 Grade CF8

Seal: NBR, Polyamide fabric reinforced Nitrile (Buna–N)

Upper Plug: Brass

Shaft Lock Nut: Stainless Steel 303 ASTM A582 95B S30300A

Shaft Nut: Stainless Steel 316 ASTM A320 Grade B8F

Diaphragm Washers: Stainless Steel 431 ASTM A743 Grade CA15M

Diaphragm: NBR, Polyamide fabric reinforced Nitrile (Buna–N)

Bearing Screw: Stainless Steel 303 ASTM A582 95B S30300A

Bearing: Bronze ASTM B505 Grade C83600

Shaft: Stainless Steel 303 ASTM A582 95B S30300A

Seal Disk: Stainless Steel 431 ASTM A743 Grade CA15M

3.1 SPECIFICATIONS - MATERIAL

Series 867-7UL, 867-7UF, 867-759 Body Style

Cover Bolt

Cover

Cover Nut

Separation Partition

Stud Nut

Valve Body

Spring

Removable Seat

Upper PlugShaft Lock Nut

Shaft Nut

Diaphragm WasherDiaphragm

Bearing Screw

Bearing

Shaft

Seal Disk

Seal

5

victaulic.com

Page 6: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

3.2 SPECIFICATIONS - MATERIAL

Series 867-42T, 867-43T Body Style

Body and Cover: (specify choice)*

Ductile Iron - ASTM A536 Grade 65-45-12

Optional: Cast Steel ASTM A216 Grade WCB

Optional: Stainless Steel 316 ASTM A351 Grade CF8M

Optional: Nickel Aluminum Bronze ASTM B148, Grade C95800

Optional: Super Duplex ASTM A890 Grade 5A

Optional: Hastelloy ASTM B336 Grade C276

Optional: Titanium ASTM B367 Grade C2 / C3

External Bolts: (specify choice)

Standard: Stainless steel 316 ASTM A276

Diaphragm Assembly: (specify choice)

Standard: NR - Fabric Reinforced Polyisoprene

Optional: Fabric Reinforced Nitrile (Buna-N)

Optional: Fabric Reinforced Ethylene-Propylene

Coating: (specify choice)

Standard: Electrostatic Powder Coating Polyester

Optional: High Build Epoxy Fusion-Bonded with UV Protection, Anti-Corrosion

Limit switch double/single: (specify choice)

Wetted internal parts - AISI 316, Monel, or Hastelloy.

Visual position indicator: (specify choice)

Wetted internal parts - AISI 316, Monel, or Hastelloy.*Note: Flanged end connection available in all materials, grooved and threaded available in ductile iron only.

External Bolts

Body and Cover

Visual Indicator

Limit Switch

Diaphragm Assembly

Coating

6

victaulic.com

Page 7: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

4.0 DIMENSIONS

Series 867–400, 867-4UF, 867-459

SizeFlanged ANSI Class 150 Grooved (OGS)Dimensions Weight3 Dimensions Weight3

Nominal

Actual Outside Diameter LF W H RF

Approx.

(Each) LG W H RG

Approx.

(Each)inches

DNinches mm

inches mm

inches mm

inches mm

inches mm

lb kg

inches mm

inches mm

inches mm

inches mm

lb kg

2 2.375 8.13 6.13 2.88 3.13 20 8.06 4.75 2.94 1.19 11DN50 60.3 205 155 74 78 9 205 120 74 30 5

3 3.5 10.13 7.88 4.38 3.88 42 9.81 6.88 4.31 1.75 23DN80 88.9 257 200 110 100 19 250 175 110 44.5 10.6

4 4.5 12.63 8.75 5.13 4.5 62 12.63 7.88 5.13 2.25 36DN100 114.3 320 223 130 115 28 320 200 130 57 16.2

6 6.625 16.38 12 8.13 5.5 150 16.31 12.06 12.38 3.25 108DN150 168.3 415 306 205 140 68 415 306 205 84.2 49

8 8.625 19.63 14.38 10.13 6.75 276 19.63 14.38 10.13 4.38 238DN200 219.1 500 365 256 172 125 500 365 256 110 108

10 10.75 23.81 16 10.13 8 309– – – – –

DN250 273 605 405 256 204 14012 12.75 28.5 24 14.63 9.5 485

– – – – –DN300 323.9 725 610 373 242 220

3 Weight based on standard ASTM A536 65-45-12 Ductile Iron Body

SizePorts - All End Connections

Dimensions

Nominal

Actual Outside Diameter a4 b4 c4 d5 Control Volume6

inches DN

inches mm

inches mm

inches mm

inches mm

inches mm

gallons liters

2 2.375 0.5 0.25 0.5 0.75 0.03DN50 60.3 15 8 15 20 0.12

3 3.5 0.5 0.25 0.5 1.5 0.08DN80 88.9 15 8 15 40 0.29

4 4.5 0.5 0.25 0.5 2 0.18DN100 114.3 15 8 15 50 0.67

6 6.625 0.5 0.25 0.5 2 0.51DN150 168.3 15 8 15 50 1.94

8 8.625 0.5 0.25 0.5 2 1.02DN200 219.1 15 8 15 50 3.86

10 10.75 0.5 0.25 0.5 2 1.02DN250 273 13 6 13 51 3.86

12 12.75 0.5 0.38 0.5 2 3.65DN300 323.9 13 6 13 51 13.8

4 (a), (b), (c) are NPT Thread ports 5 (d) is BSPT threaded optional drain port 6 (Control Volume) is Control Chamber Displacement Volume of Liquid pushed when valve opens

ad

LF

a

LG

ad

a

LT

ad

a

b

C bb

RT

H

H

RF

H

RG

W

ad

LF

a

LG

ad

a

LT

ad

a

b

C bb

RT

H

H

RF

H

RG

W

7

victaulic.com

Page 8: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

4.1 DIMENSIONS

Series 867–7UL, 867-7UF, 867-759

Size

Grooved (OGS)

Flanged ANSI

Class 150 Flanged ANSI Class 150 and GroovedFlanged

ANSI Class 150Dimensions Weight7

Nominal

Actual Outside Diameter LG8 L W R La ha Hy Ha

Y Approx.

(Each)

A Approx.

(Each)inches

DNinches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

lb kg

lb kg

1 ½ 1.9 8.1 8.1 6.1 3.1 4.9 3.3 9.4 8.9 23 22DN40 48.3 205 205 165 78 124 85 239 227 10.6 10

2 2.375 8.1 8.1 6.1 3.3 4.9 3.3 9.6 8.9 23 22DN50 60.3 205 205 165 83 124 85 244 227 10.6 10

2 ½ 2.875 8.3 8.3 7 3.7 5.9 4.3 10.1 9.9 29 2773 222 222 178 95 149 109 257 241 13 12

3 3.5 9.8 9.8 7.9 3.9 6 4 12 11.1 49 47DN80 88.9 250 250 200 100 152 102 305 281 22 21.5

4 4.5 12.6 12.6 8.8 4.5 7.5 5 14.4 13.5 82 77DN100 114.3 320 320 223 115 190 127 366 342 37 35

6 6.625 16.4 16.3 12.6 5.6 8.9 6 19.4 17.4 165 157DN150 168.3 415 415 320 143 225 152 492 441 75 71

8 8.625 19.7 19.7 15.4 6.8 10.4 8 23 21.5 276 260DN200 219.1 500 500 390 172 265 203 584 545 125 118

10 10.75–

23.8 18.9 8 12.6 8.6 28.5 24.9 478 452DN250 273 605 480 204 320 219 724 633 217 205

12 12.75–

28.5 21.7 9.5 15.6 10.7 33.1 30.6 816 772DN300 323.9 725 550 242 396 273 840 777 370 350

14 14–

28.9 21.7 10.6 15.7 11 34.1 30.7 840 216DN350 355.6 733 550 268 400 279 866 781 381 370

16 16–

39 29.1 11.8 17.7 14.5 43.6 42.6 1865 1764DN400 406.4 990 740 300 450 369 1,108 1,082 846 800

7 Weight based on standard ASTM A536 65-45-12 Ductile Iron Body8 LG is for Grooved ends (see available sizes)

NOTE• Dimensions and port dimensions (a, b, c, d) continued on page 9

dL & LG

a

cb

a

b

c

b

cLa

a

cb

a

Hy

R

W

Ha

ha

dL & LG

a

cb

a

b

c

b

cLa

a

cb

a

Hy

R

W

Ha

ha

8

victaulic.com

Page 9: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

4.1 DIMENSIONS (Continued)

Series 867–7UL, 867-7UF, 867-759

SizeFlanged ANSI Class 300

Dimensions Weight9

Nominal

Actual Outside Diameter L W R La ha Hy Ha

Y Approx.

(Each)

A Approx.

(Each)inches

DNinches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

lb kg

lb kg

1 ½ 1.9 8.3 6.5 3.1 4.9 3.3 9.4 8.9 27 25DN40 48.3 210 165 78 124 85 239 227 12.2 11.5

2 2.375 8.3 6.5 3.3 4.9 3.3 9.6 8.9 27 25DN50 60.3 210 165 83 124 85 244 227 12.2 11.5

2 ½ 2.875 8.7 7.3 3.7 5.9 4.3 10.1 9.9 33 3073 222 185 95 149 109 257 251 15 13.5

3 3.5 10.4 8.1 4.1 6.3 4.3 12.4 11.3 55 51DN80 88.9 264 207 105 159 109 314 287 25 23

4 4.5 13.2 9.8 5 7.9 5.3 14.9 13.8 95 90DN100 114.3 335 250 127 200 127 378 650 43 41

6 6.625 17 12.6 6.3 9.2 6.5 20 17.9 187 179DN150 168.3 433 320 159 234 165 508 454 85 81

9 Weight based on standard ASTM A536 65-45-12 Ductile Iron Body

SizeThreaded NPT or BSP Ports - All End Connections

Dimensions Dimensions

Nominal

Actual Outside Diameter L W R La ha Hy Ha a10 b10 c10

d11

(optional)Control

Volume12

inches DN

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

gallons liters

1 ½ 1.9 – – – – – – – 0.5 0.5 0.75 0.75 0.04DN40 48.3 15 15 20 20 0.13

2 2.375 6.1 15 1.6 4.8 3.3 12.3 15.6 0.5 0.5 0.75 0.75 0.04DN50 60.3 155 382 40 120 82 312 394 15 15 20 20 0.13

2 ½ 2.875 8.4 15 1.9 5.5 4 12.3 16.3 0.5 0.5 0.75 1.5 0.0473 212 382 48 140 102 312 414 15 15 20 40 0.125

3 3.5 9.8 16.1 42 6 4.5 14.5 19 0.5 0.5 0.75 1.5 0.08DN80 88.9 250 414 110 152 114 364 478 15 15 20 40 0.3

4 4.5 – – – – – – – 0.5 0.5 0.75 2 0.12DN100 114.3 15 15 20 50 0.45

6 6.625 – – – – – – – 0.5 0.5 2 2 0.57DN150 168.3 15 15 50 50 2.15

8 8.625 – – – – – – – 0.5 0.5 2 2 1.19DN200 219.1 15 15 50 50 4.5

10 10.75 – – – – – – – 0.5 0.5 2 2 2.25DN250 273 15 15 50 50 8.5

12 12.75 – – – – – – – 0.5 0.5 2 2 3.28DN300 323.9 15 15 50 50 12.4

14 14 – – – – – – – 0.5 0.5 2 2 3.28DN350 355.6 15 15 50 50 12.4

16 16 – – – – – – – 0.5 0.5 2 2 7.88DN400 406.4 15 15 50 50 29.9

10 (a), (b), (c) are NPT Thread ports 11 (d) is BSPT threaded optional drain port 12 (Control Volume) is Control Chamber Displacement Volume of Liquid pushed when valve opens

dL & LG

a

cb

a

b

c

b

cLa

a

cb

a

Hy

R

W

Ha

ha

dL & LG

a

cb

a

b

c

b

cLa

a

cb

a

Hy

R

W

Ha

ha

9

victaulic.com

Page 10: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

4.2 DIMENSIONS

Series 867-42T, 867-43T

H

RG

W

a

RF

H

d

aa

da

d

a

a

da

RT

H

d

a

a

da

LF LG

LT

H

RG

W

a

RF

H

d

aa

da

d

a

a

da

RT

H

d

a

a

da

LF LG

LT

H

RG

W

a

RF

H

d

aa

da

d

a

a

da

RT

H

d

a

a

da

LF LG

LT

H

RG

W

a

RF

H

d

aa

da

d

a

a

da

RT

H

d

a

a

da

LF LG

LT

Flanged ANSI Class 150 Flanged ANSI Class 300

Nominal

Actual Outside Diameter LF RF H W Weight LF RF H W Weight

inches DN

inches mm

inches mm

inches mm

inches mm

inches mm

lb kg

inches mm

inches mm

inches mm

inches mm

lb kg

1 ½ 1.9 9.06 2.56 4.93 5.99 21 9.06 3.11 4.93 5.99 26DN40 48.3 230 65 125 152 9.4 230 78 125 152 11.8

2 2.375 9.06 3.03 4.93 5.99 24 9.25 3.38 4.93 5.99 28DN50 60.3 230 77 125 152 10.8 235 86 125 152 12.72 1/2 2.875

– – – – – – – – – –

3 3.5 12.21 4.18 6.03 9.73 56 12.84 4.17 6.03 9.73 67DN80 88.9 310 106 153 247 25.5 326 106 153 247 30.2

4 4.5 13.79 4.77 6.42 10.4 78 14.5 5.01 6.42 10.4 95DN100 114.3 350 121 163 264 35.5 368 129 163 264 42.9

6 6.625 18.91 5.79 9.14 14.66 174 19.94 6.37 9.14 14.66 217DN160 168.3 480 147 232 372 78.8 506 162 232 372 98.6

8 8.625 23.64 7.09 11.82 19.31 313 24.66 7.59 11.82 19.31 357DN200 219.1 600 180 300 490 142 626 193 300 490 162

10 10.75 28.76 8.04 11.82 19.31 379 28.76 8.89 11.82 19.31 459DN250 273 730 204 300 490 172 730 226 300 490 208

Grooved (OGS) Threaded All

Nominal

Actual Outside Diameter LG RG H W Weight LT RT H W Weight a d

inches DN

inches mm

inches mm

inches mm

inches mm

inches mm

lb kg

inches mm

inches mm

inches mm

inches mm

lb kg

inches mm

inches mm

1 ½ 1.9 9.06 0.95 4.93 5.99 15 9.06 1.18 4.93 5.99 16.06 0.5 0.75DN40 48.3 230 24.1 125 152 6.8 230 30 125 152 7.3 21.3 26.9

2 2.375 9.06 1.19 4.93 5.99 16– – – – –

0.5 0.75DN50 60.3 230 30.2 125 152 7.1 21.3 26.92 1/2 2.875 9.25 1.44 4.93 5.99 20

– – – – –0.5 0.75

235 37 125 152 9.1 21.3 26.93 3.5 12.21 1.75 6.03 9.73 40

– – – – –0.5 1.5

DN80 88.9 310 44.5 153 247 18 21.3 48.34 4.5 13.79 2.25 6.42 10.4 53

– – – – –0.5 2

DN100 114.3 350 57.2 163 264 23.9 21.3 60.36 6.625 18.91 3.31 9.14 14.66 153

– – – – –0.5 2

DN160 168.3 480 84.2 232 372 69.6 21.3 60.38 8.625 23.64 4.33 11.82 19.31 275

– – – – –0.5 2

DN200 219.1 600 110 300 490 125 21.3 60.310 10.75

– – – – – – – – – –0.5 2

DN250 273 21.3 60.3

10

victaulic.com

Page 11: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

5.0 PERFORMANCE

Discharge Chart

Series 867-4UF

Maximum Flow Rates

Series 867-4UF

Valve Size inches mm

2 3 4 6 850 80 100 150 200

Maximum Flow gpm m3/h

250 500 1000 2500 500057 114 227 568 1136

11

victaulic.com

Page 12: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

5.0 PERFORMANCE (Continued)

Pressure Fall-off Chart

Series 867-7UL

Maximum Flow Rates and Recommended Relief Valve Sizes

Series 867-7UL

Valve Size inches mm

1½ 2 2½ 3 4 6 8 10 1240 50 65 80 100 150 200 250 300

Maximum Flow gpm LPM

80 150 150 500 800 1800 4000 6000 850018 34 34 114 182 409 908 1362 1920

Relief Valve Size inches mm

½ ½ ½ 1½ 2 2 3 4 2 x 412 12 12 40 50 50 80 100 2X100

Discharge Chart

Series 867-7UF

12

victaulic.com

Page 13: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

5.0 PERFORMANCE (Continued)

Flow Range and Recommended Relief Valve Size

Series 867-42T

Valve Size inches mm

1½ 2 2½ 3 4 6 8 1040 50 65 80 100 150 200 250

Flow Range gpm m3/h

20 – 106 20 – 172 20 – 247 20 – 360 20 – 640 20 – 1450 20 – 2570 45 – 40004 – 24 4 – 39 4 – 56 4 – 82 4 – 145 4 – 330 4 – 580 10 – 910

Relief valve Recommended Size

inches mm

¾ ¾ 1½ 1½ 2 3 3 420 20 40 40 50 80 80 100

NOTE• For pressure fall-off charts please see Victaulic.

• Must be installed with a minimum of ½" relief valve for FM Approved installations

Discharge Chart

Series 867-43T

13

victaulic.com

Page 14: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

5.1 PERFORMANCE

Flow Chart

Series 867–400, 867-4UF, 867-459

Flow Chart

Series 867–7UL, 867–7UF, 867–759

FLOW RATE – GPM / m3/h

P

RE

SS

UR

E D

RO

P –

PS

I / B

ar

0.01

0.05

0.1

0.5

1.0

0.15

0.25

0.50

0.75

1.00

1.25

1.50

2.50

5.00

7.50

10.00

12.5015.00

5 10 20 30 40 50 100 200 300 500 1,000 20 30 40 50 75 100 500 1,000 5,000

1½"/4

0mm

2"/5

0mm

2½"/6

5mm

3"/8

0mm

4"/10

0mm

6"/1

50mm

8"/2

00mm

10"/2

50mm

12"/3

00mm

FLOW RATE – GPM / m3/h

PR

ES

SU

RE

DR

OP

– P

SI

/ Bar

50 75 100 250 500 750 1,000 2,500 5,000 7,500 10,000 15,000 20,00010 50 100 500 1,000 5,000

15.0

12.5

10.0

7.5

5.0

2.5

1.5

1.0

0.5

0.1

1½"/4

0mm

2"/50m

m2½

"/65m

m

3"/80m

m

4"/100mm

6"/150

mm

8"/200

mm

10"/2

50mm

12"/3

00mm

14"/3

50mm

16"/4

00mm

14

victaulic.com

Page 15: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

5.1 PERFORMANCE (Continued)

Flow Chart

Series 867-42T, 867-43T

FLOW RATE – GPM / m3/h

PR

ES

SU

RE

DR

OP

– P

SI

/ Bar

15

10987654

3

2

10.90.80.70.60.5

0.4

0.3

0.2

0.120

0.01

0.02

0.03

0.04

0.050.060.070.080.09

0.1

0.2

0.3

0.4

0.50.60.70.80.91.0

5 10 20 30 40 50 100 200 300 400 500 1000 2000 300030 40 50 70 100 200 300 400 500 700 1000 2000 3000 4000 5000 7000 10000 15000

1½"/4

0mm

2"/5

0mm

4"/1

00m

m

6"/1

50m

m8"

/200

mm

10"/2

50m

m

3"/8

0mm

2½"/7

3mm

15

victaulic.com

Page 16: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

5.2 PERFORMANCE

Series 867–400, 867-4UF, 867-459

CV Values:

CV values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below.

Formulas for CV and KV values

Frictional Resistance

The chart below expresses the frictional resistance of Victaulic Series 867-400, 867-4UF, and 867-459 Pressure Reducing and Pressure Relief Valves in equivalent feet of straight pipe.

Valve Size Full Open

Equivalent Length of

Pipe

Nominal Size

Actual Outside Diameter Flow Coefficient

inches DN

inches mm

Cv Kv

feet meters

1 ½ 1.9 66 30DN40 48.3 57 9.1

2 2.375 66 30DN50 60.3 57 9.12 ½ 2.875 90 40

73 78 12.13 3.5 157 45

DN80 88.9 136 13.74 4.5 236 46

DN100 114.3 204 146 6.625 529 90

DN150 168.3 458 27.48 8.625 902 150

DN200 219.1 781 45.810 10.75 957 354

DN250 273 829 10812 12.75 2231 187

DN300 323.9 1932 57

Where:

or

Flow Coefficient Cv Kv

Q (Flow) GPM m3/hr

ΔP (Pressure Drop) psi bar

∆P = Q2

Cv2

Q = Cv x ∆P

Where:Q = Flow (GPM)∆P = Pressure Drop (psi)Cv = Flow Coe�cient

Q = Flow (m3/hr)∆P = Pressure Drop (Bar)K

v = Flow Coefficient

Where:

16

victaulic.com

Page 17: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

5.3 PERFORMANCE

Series 867–7UL, 867-7UF, 867-759

CV Values:

CV values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below.

Formulas for CV and KV values

Frictional Resistance

The chart below expresses the frictional resistance of Victaulic Series 867-7UL, 867-7UF, and 867-759 Pressure Reducing and Pressure Relief Valves in equivalent feet of straight pipe.

Valve Size Full Open

Equivalent Length of

Pipe

Nominal Size

Actual Outside Diameter Flow Coefficient

inches DN

inches mm

Cv Kv

feet meters

1 ½ 1.9 58 33.8DN40 48.3 50 10.3

2 2.375 58 33.8DN50 60.3 50 10.32 ½ 2.875 64 109.5

73 55 33.43 3.5 133 70.8

DN80 88.9 115 21.64 4.5 230 75.6

DN100 114.3 200 236 6.625 530 123.0

DN150 168.3 460 37.58 8.625 940 176.9

DN200 219.1 815 53.910 10.75 1440 229.5

DN250 273 1250 7012 12.75 2140 280.8

DN300 323.9 1850 85.614 14 2300 524.5

DN350 355.6 1990 159.916 16 3820 369.6

DN400 406.4 3310 112.7

Where:

or

Flow Coefficient Cv Kv

Q (Flow) GPM m3/hr

ΔP (Pressure Drop) psi bar

∆P = Q2

Cv2

Q = Cv x ∆P

Where:Q = Flow (GPM)∆P = Pressure Drop (psi)Cv = Flow Coe�cient

Q = Flow (m3/hr)∆P = Pressure Drop (Bar)K

v = Flow Coefficient

Where:

17

victaulic.com

Page 18: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

5.4 PERFORMANCE

Series 867-42T, 867-43T

CV Values:

CV values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below.

Formulas for CV and KV values

Frictional Resistance

The chart below expresses the frictional resistance of Victaulic Series 867-42T and 867-43T Pressure Reducing and Pressure Relief Valves in equivalent feet of straight pipe.

Valve Size Full Open

Equivalent Length of

Pipe

Nominal Size

Actual Outside Diameter Flow Coefficient

inches DN

inches mm

Cv Kv

feet meters

1 ½ 1.9 79 7DN40 48.3 68 2

2 2.375 92 16DN50 60.3 80 52 ½ 2.875 116 28

73 100 8.63 3.5 219 23

DN80 88.9 190 74 4.5 398 30

DN100 114.3 345 96 6.625 912 49

DN150 168.3 790 158 8.625 1160 89

DN200 219.1 1160 2710 10.75 1662 203

DN250 273 1355 62

Where:

or

Flow Coefficient Cv Kv

Q (Flow) GPM m3/hr

ΔP (Pressure Drop) psi bar

∆P = Q2

Cv2

Q = Cv x ∆P

Where:Q = Flow (GPM)∆P = Pressure Drop (psi)Cv = Flow Coe�cient

Q = Flow (m3/hr)∆P = Pressure Drop (Bar)K

v = Flow Coefficient

Where:

18

victaulic.com

Page 19: Victaulic Pressure Valves Series 867-400, 867-4UF, … · 200 12 2 – 11.5 867-7UF 2 – 6 200 350 30 – 175 ... Class 300 NPT / BSP Flanged ANSI Class 150 Flanged ANSI Class 300

30.93 8614 Rev C Updated 11/2016 © 2016 Victaulic Company. All rights reserved.

victaulic.com

User Responsibility for Product Selection and SuitabilityEach user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer.

Intellectual Property RightsNo statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries.

NoteThis product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.

InstallationReference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com.

WarrantyRefer to the Warranty section of the current Price List or contact Victaulic for details.

TrademarksVictaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries.

6.0 NOTIFICATIONS

WARNING

• Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products.

• Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products.

• Wear safety glasses, hardhat, and foot protection.

Failure to follow these instructions could result in death or serious personal injury and property damage.

7.0 REFERENCE MATERIALS10.64: Victaulic® Firelock™ Rigid Coupling Style 009N

I-100: Field Installation Handbook

I-009N: Field Installation and Maintenance Style 009N

29.01: Terms and Conditions

I-867-7UL: Installation, Operation and Maintenance Manual Series 867-7UL

I-867-7UF: Installation, Operation and Maintenance Manual Series 867-7UF

I-867-4UF: Installation, Operation and Maintenance Manual Series 867-4UF

I-867-42T: Installation, Operation and Maintenance Manual Series 867-42T

I-867-43T: Installation, Operation and Maintenance Manual Series 867-43T

19

victaulic.com