Page 1: VI Presentation cmf

Vapor IntrusionThe Invasion From Below

Christina M. Faust, Senior Project Manager, WhitmanMike Adams, Project Scientist, Whitman

Page 2: VI Presentation cmf

2

OverviewWhat is Vapor Intrusion (VI)?

Why Should I Care?Causes of VI

Identifying and Investigating the problemFixing the problem

Page 3: VI Presentation cmf

3

What is Vapor Intrusion?NJDEP: … migration of volatile chemicals from the subsurface into overlaying buildings through subsurface soils or preferential pathways.USEPA: … migration of hazardous vapors from any subsurface vapor source, such as contaminated soil or ground water, through the soil into an overlying building or structure.

Page 4: VI Presentation cmf

4

Key Terms in the VI world• Vapor• VIG or VITG – Vapor Intrusion Guidance/ Vapor Intrusion Technical Guidance• SSSG –Sub-slab Soil Gas• IA – Indoor Air• IEC – Immediate Environmental Concern• OMM – Operations Maintenance and Monitoring• Res v Non-Res• LSRP – Licensed Site Remediation Professional

• RAL – Rapid Action Level• Capillary fringe• Vadose zone• Attenuation factor• Ambient Air• Critical distance• LTM – Long Term Monitoring• VC – Vapor Concern

Enough with the Acronyms!!

Page 5: VI Presentation cmf

5

Why Should I Care?• The VI “Pathway”

– Health impacts of contaminants• Regulatory and Legal Implications

– Buying property– Developing land– Deed Notices & CEAs– Legacy concerns

• Getting ahead of a Problem– Prevention– Mitigation

Page 6: VI Presentation cmf

6

The Vapor Intrusion PathwayKey Concepts:1. Contaminant Source2. Contaminant Migration3. Contaminant Exposure (Contaminants are Entering the Building )Collectively, these 3 concepts complete theVI Pathway - Without any 1 feature, Vapor Intrusion cannot exist. Other breathing hazards can still exist.

Page 7: VI Presentation cmf

7

A Picture Tells a Thousand Words

Source : NJDEP Vapor Intrusion Technical Guidance (2013)

Page 8: VI Presentation cmf

8

Source : USEPA OSWER Technical Guidance (2015)

Page 9: VI Presentation cmf

9

Is There a Problem?DUE DILIGENCE!

In NJ, this usually means a Phase I/Preliminary Assessment Report.A proper DD assessment will include diligent inquiry into subject and surrounding property conditions that could cause VI. Remember: Due Diligence is only as good as the party conducting the assessment!

Page 10: VI Presentation cmf

10

How is VI Investigated?Source (Typically in ground water, but can be soil)

Migration (Frequently Sub-Slab Soil Gas)

Building (Indoor Air)

Page 11: VI Presentation cmf

11

Sampling Ground Water• Only concerned with the top 6 feet of water column

Page 12: VI Presentation cmf

12

Sample Sub-Slab Soil Gas• Samples generally collected over ~10 minute period, although time may vary• Major Concerns: “Short circuiting” of soil gas with indoor air

Page 13: VI Presentation cmf

13

Sample Indoor Air• Samples usually collected over a 24-hour period• Sample at breathing height• Major Concern: Background Sources

Page 14: VI Presentation cmf

14

Background SourcesBackground Sources can cause false positives and costly, unnecessary mitigation. Accounting for background sources:

1. Additional Outdoor Air Sample – “Ambient”2. Detailed Chemical Inventory and Building Survey3. Knowledge of building history (D.D.)

Page 15: VI Presentation cmf

15

Building/Chemical Inventory

Page 16: VI Presentation cmf

Background Sources

16

Source : NJDEP Vapor Intrusion Technical Guidance (2013)

Page 17: VI Presentation cmf

17

Data Interpretation

Source : NJDEP Vapor Intrusion Technical Guidance (2013)Suggests

BackgroundSuggests

VI

Page 18: VI Presentation cmf

18

Multiple Lines of Evidence• NJDEP is pushing investigators to provide “Multiple Lines of Evidence” supporting the conclusion that VI is (or is not) an issue at a property. • Additional lines of evidence could include• Soil Characteristics•Building Conditions•Contaminant Ratios in Soil Gas vs. Indoor Air…

Page 19: VI Presentation cmf

19

Time is of the Essence - Regulatory Impacts• VI must be investigated 150 days from identification of a potential VI issue.• If an Immediate Environmental Concern is identified, interim mitigation is required to commence within 14 days of identification of an issue (i.e. receipt of sample results).• Other regulatory timeframes may also apply

Page 20: VI Presentation cmf

20

VI Identified… What next?Mitigation is required

NJDEP considers Active Sub-Slab Depressurization Systems (SSDS) as the best method of VI mitigation.So, what is an Active SSDS?

Page 21: VI Presentation cmf

21

Active SSDS• A SSDS depressurizes the sub-slab and prevents the migration of impacted soil gas into the structure.• Very similar to a Radon Mitigation System, but with more diagnostic checks and regulatory requirements

Page 22: VI Presentation cmf

22

Active SSDS

Page 23: VI Presentation cmf

23

Active SSDS

Warehouse in New Jersey:• 7-Sump/1-Blower System• Mitigation area of approximately 30,000 sq. ft.

Page 24: VI Presentation cmf

24

Active SSDSProper SSDS Design is dependent on:

•Building Use•Construction Type•Soil Permeability

Each building requires a tailored approach

Page 25: VI Presentation cmf

25

Alternate Mitigation Approaches – Long Term MonitoringLong Term Monitoring can be appropriate and cost effective when soil gas is elevated, but indoor air clean. It is particularly cost effective if there are near term plans for site redevelopment.

Page 26: VI Presentation cmf

26

Alternate Mitigation Approaches – Passive SSDS • Similar to an Active SSDS, but there are no powered fans.•Passive SSDS can usually be converted to Active if needed. • Particularly cost effective in new construction where there is an identified potential for VI and construction can include the installation of a sub-slab venting layer.

Page 27: VI Presentation cmf

27

Alternate Mitigation Approaches – Passive SSDSNJDEP guidance references the Cupolex system as one such venting layer, however there are many such products

Page 28: VI Presentation cmf

28

Alternate Mitigation Approaches There are other mitigation techniques as well:• Building Pressurization• Soil Vapor Extraction systems• Aerated floor systems• Spray on Barriers (in conjunction w/ other approaches)• Sub-Surface Pressurization• Restriction of building accessMitigation approach should be tailored to the building on a case by case basis.

Page 29: VI Presentation cmf

29

Case Study: Ironbound, Newark• Ronson Metals Corp. manufactured lighters in Newark from 1950s to 1989• Environmental investigation had been ongoing, but abruptly ceased in the mid-1990s • Ground water was not properly investigated, fell through the cracks •In 2003, the property was redeveloped with residential homes

Page 30: VI Presentation cmf

30

Case Study: Ironbound, Newark

Source: http://www.nj.com/essex/index.ssf/2014/04/newark_homes_not_so_sweet_with_toxic_vapors_seeping_inside.html

Page 31: VI Presentation cmf

31

Case Study: Ironbound, Newark

Source: http://www.nj.com/essex/index.ssf/2014/04/newark_homes_not_so_sweet_with_toxic_vapors_seeping_inside.html

Page 32: VI Presentation cmf

32

Case Study: Ironbound, Newark

Currently site is identified in NJDEP Mapping Software as Deed Restricted, but known ground water contamination is not mapped as investigation is ongoing.

Source: NJDEP GeoWeb

Page 33: VI Presentation cmf

33

Case Study: Ironbound, NewarkAs of December 2015:• 59 residences have been sampled for potential VI issues.• 28 Active Sub-Slab Depressurization Systems have been installed.• The investigation of ground water and potential VI issues is ongoing.

Page 34: VI Presentation cmf

34

Case Study: Ironbound NewarkLessons: • VI impacts can be “missed” – especially in older cases• Regardless of blame, litigation can be costly• Proper Due Diligence is the Key to Assessing Risk

Page 35: VI Presentation cmf

35

In Conclusion• VI is a necessary consideration for building in NJ, residential or commercial• Assessment of VI potential is an important step in calculating purchase/development risk - Professional due diligence by is critical• There are regulatory and legal ramifications to be aware of • If a risk exists, there are solutions – pre and post construction• VI can be a hurdle - it does not have be a deal breakerFinally, VI is not the sole aspect of a site that can affect indoor air quality, as demonstrated by the now famous Kiddie Kollege case…

Page 36: VI Presentation cmf

36

Case Study - Kiddie Kollege

Page 37: VI Presentation cmf

37

Questions?Christina M. Faust Project Manager, [email protected] AdamsProject Scientist, [email protected]