Vertical Multi-Stage In-Line Pumps Construction Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line). Corrosion-resistant bearing sleeves lubricated by the pumped liquid. Removal of the mechanical seal without dismantling the motor (for MXV 50, MXV 100 with motors exceeding 4 KW). A pump with thrust bearing and sleeve coupling for use of any standard motor with IM V1 construction. Version with frequency converter (on request) Applications For water supply systems. For clean non-explosive liquids, without solid, filamentary or abrasive matter (with adaptation of sealing materials on request). A universal pump for civil and industrial use, for pressure-boosting systems, fire-extinguishing systems, high-pressure washing plants, irrigation, agricultural uses and sport installations. Operating conditions Temperature of liquid: from -15 °C to +110 °C (up to +120 °C for MXV 50). Operating environment temperature: up to 40 °C. Maximum permissible pressure in pump casing: 25 bar. (16 bar for pumps with oval flanges). Motor Standard-type: 2-pole induction motor, 50 Hz (n ≈ 2900 rpm). Construction IM V1 (EN 60034-7). Motor suitable for operation with frequency converter. Classification scheme IE3 for three-phase motors. Insulation class F. Protection IP 55. three-phase with rated voltage: up to 3 kW 230/400 V; from 4 kW 400/690 V. MXV 25, 32, 40, 50 MXV 65, 80, 100 Component Material Flange External jacket Suction casing Delivery casing Stainless Steel Stage casing 1.4301 EN 10088 (AISI 304) Impeller Lower cover Upper cover Spacer sleeve Pump shaft Stainless Steel 1.4305 EN 10088 (AISI 303) Plug (for MXV 50 AISI 304) Bearing sleeve Corrosion-resistant, cemented carbide Bearing in stage casing Ceramic alumina Mechanical seal ISO 3069 - KU Hard metal/Carbon/EPDM. Wear ring PPS (PTFE for MXV 40) O-rings NBR (EPDM for MXV 50) Pump with threaded ports (G) (for MXV 25, 32, 40). Pump with flanged ports (F). Pump with oval flange ports (O) (for MXV 50). Pump without motor. Pump with standard motor. Variants (to be specified when ordering) With counter-flanges in chrome-nickel steel. O-rings FPM. Other mechanical seal. Pump with motor of Client's choice (if available). Single-phase motor 230 V, up to 2.2 kW. Other voltage ratings. Frequency 60 Hz. Other variants (on request) Materials (wetted parts) All parts that come into contact with the liquid, including wet-end covers, are in chrome-nickel stainless steel AISI 304. Internal parts in contact with the liquid in chrome-nickel stainless steel, AISI 304 with pump casing and upper cover in cast iron. Direction of rotation: clockwise as seen from the motor. Component Material Pump casing Cast iron GJL 250 EN 1561 Upper cover External jacket Stage casing Stainless Steel 1.4301 EN 10088 (AISI 304) Impeller Spacer sleeve Pump shaft Stainless Steel (AISI 303)(AISI 431 for MXV 100) Plug Stainless Steel (AISI 303)(AISI 304 for MXV 100) Bearing sleeve Corrosion-resistant, cemented carbide Bearing in stage casing Ceramic alumina (Corrosion-resistant, cemented carbide for MXV 100) Mechanical seal ISO 3069 - KU Hard metal/Carbon/EPDM Wear ring PTFE O-rings NBR (EPDM for MXV 100) Materials (wetted parts) Pump without motor. Pump with standard motor. Variants (to be specified when ordering) O-rings FPM. Other mechanical seal. Pump with motor of Client's choice (if available). Other voltage ratings. Frequency 60 Hz. Pump with support feet for horizontal installation (H1 or H2). Support feet for horizontal installation, set. Welding counter-flanges, PN 25 (steel). Other variants (on request) The electropumps MXV series comply with the European Regulation no. 547/2012. Direction of rotation: anticlockwise as seen from the motor. (clockwise as seen from the motor for MXV 100) MXV

Upload: others

Post on 18-Oct-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

Vertical Multi-Stage In-Line Pumps

ConstructionVertical multi-stage pumps with suction and delivery connectionsof the same diameter and arranged along the same axis (in-line).Corrosion-resistant bearing sleeves lubricated by the pumped liquid.Removal of the mechanical seal without dismantling the motor(for MXV 50, MXV 100 with motors exceeding 4 KW).A pump with thrust bearing and sleeve coupling for use of anystandard motor with IM V1 construction.

Version with frequency converter (on request)

ApplicationsFor water supply systems.For clean non-explosive liquids, without solid, filamentary orabrasive matter (with adaptation of sealing materials on request).A universal pump for civil and industrial use, for pressure-boostingsystems, fire-extinguishing systems, high-pressure washingplants, irrigation, agricultural uses and sport installations.

Operating conditionsTemperature of liquid: from -15 °C to +110 °C (up to +120 °Cfor MXV 50).Operating environment temperature: up to 40 °C.Maximum permissible pressure in pump casing: 25 bar. (16 bar for pumps with oval flanges).

MotorStandard-type: 2-pole induction motor, 50 Hz (n ≈ 2900 rpm).Construction IM V1 (EN 60034-7).Motor suitable for operation with frequency converter.Classification scheme IE3 for three-phase motors.Insulation class F.Protection IP 55.three-phase with rated voltage: up to 3 kW 230/400 V;

from 4 kW 400/690 V.

MXV 25, 32, 40, 50 MXV 65, 80, 100

Component Material

FlangeExternal jacketSuction casingDelivery casing Stainless SteelStage casing 1.4301 EN 10088 (AISI 304)ImpellerLower coverUpper coverSpacer sleevePump shaft Stainless Steel 1.4305 EN 10088 (AISI 303)Plug (for MXV 50 AISI 304)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic aluminaMechanical sealISO 3069 - KU Hard metal/Carbon/EPDM.

Wear ring PPS (PTFE for MXV 40)O-rings NBR (EPDM for MXV 50)

Pump with threaded ports (G) (for MXV 25, 32, 40).Pump with flanged ports (F).Pump with oval flange ports (O) (for MXV 50).Pump without motor.Pump with standard motor.

Variants (to be specified when ordering)

With counter-flanges in chrome-nickel steel.O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Single-phase motor 230 V, up to 2.2 kW.Other voltage ratings. Frequency 60 Hz.

Other variants (on request)

Materials (wetted parts)

All parts that come into contact with the liquid, including wet-endcovers, are in chrome-nickel stainless steel AISI 304.

Internal parts in contact with the liquid in chrome-nickel stainless steel,AISI 304 with pump casing and upper cover in cast iron.

Direction of rotation: clockwise as seen from the motor.

Component Material

Pump casing Cast iron GJL 250 EN 1561Upper cover

External jacketStage casing Stainless Steel 1.4301 EN 10088 (AISI 304)ImpellerSpacer sleevePump shaft Stainless Steel (AISI 303)(AISI 431 for MXV 100)Plug Stainless Steel (AISI 303)(AISI 304 for MXV 100)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic alumina

(Corrosion-resistant, cemented carbide for MXV 100)Mechanical sealISO 3069 - KU

Hard metal/Carbon/EPDM

Wear ring PTFEO-rings NBR (EPDM for MXV 100)

Materials (wetted parts)

Pump without motor.Pump with standard motor.

Variants (to be specified when ordering)

O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Other voltage ratings. Frequency 60 Hz. Pump with support feet for horizontal installation (H1 or H2).Support feet for horizontal installation, set. Welding counter-flanges, PN 25 (steel).

Other variants (on request)

The electropumps MXV series comply with the European Regulation no. 547/2012.

Direction of rotation: anticlockwise as seen from the motor.(clockwise as seen from the motor for MXV 100)

MXV

Page 2: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

MXV EI Vertical Multi-Stage In-Line Pumps

Pumps with frequency converter

The MXV EI pumps are available with power from 0,75 kW up to 22 kW,the pumps are equipped with I-MAT installed on board which allows torealize a variable-speed system extremely compact and efficient, ideal inapplications of water supply and in the distribution of hot and cold water. The pump is equipped with transducers suitable for operation and isalready programmed at the factory.

Advantages- Energy saving- Compact design- Easy to use- Programmable to suit the system requirements- Reliability

CostructionThe system comprises of:- Pump- Induction motor- I-MAT Frequency converter- Motor adapter for the motor mounting of the frequency converter- Connection cable between frequency converter and induction motor- Transducers

Main featuresRated motor power output from 0,75 kW to 22 kWControl range from 1750 to 2900 rpm (2-pole) Protection against dry runningProtection against operations with closed connection portsProtection against system leakagesProtection against overcurrent in the motorProtection agains overvoltage and undervoltage of the power supplyProtection against current unbalances between phases

Mode at a constant pressurewith pressure sensor

In this mode, the system maintains the preset pressure when the flow required bythe installation changes.

Proportional pressure mode with pressure sensor

In this mode the system changes the working pressure according to the requiredflow rate.

Constant flow mode with flow meter

In this mode the system maintains a constant flow rate value in a point of theinstallation according to the required pressure.

Fixed speed mode with setting of the speed preferential rotation.

In this mode, by changing the working frequency, you may choose any operationalcurve included within the working range.

Constant temperature modewith temperature transducerIn this mode the system keeps the temperature constant inside a system bychanging the speed of the pump.

Operating modesH

Q

H

Q

H

Q

H

max

min

+-

+-

+ -

+-

Page 3: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

MXV

3.93.013

4.93.213/1

4.93.213/2 4.93.213/3 4.93.213/4

Pipe connection

Pump with threaded ports:pipes screwed into the ports

Pump with threaded ports:pipes with union couplings(locally available)

Pump with flanged ports:pipes with counter-flanges

Installations

Vertical installation(Standard).

Horizontal installation. Variant H1: suction on the left, delivery on the right.

Variant H2: suction on the right, delivery on the left.

4567810

25-20425-20525-20625-20725-20825-210

25-212

25-214

25-21625-218

25-220

40-81740-819

32-412

32-414

32-41632-418

40-811

40-813

40-815

32-40432-40532-40632-40732-40832-410

40-80440-80540-80640-80740-80840-810

111111

2222222

333

11121314151618

171920

MXV

12345678

65-320865-320965-3210

65-3212

65-320265-320365-320465-320565-320665-3207

50-150150-150250-150350-150450-150550-150650-150750-1508

50-150950-151050-151150-151250-1513

50-151450-151550-151650-1517

50-200150-200250-200350-200450-200550-200650-200750-2008

50-200950-201050-201150-201250-2013

50-201450-201550-201650-2017

80-480680-480780-4808

80-480180-480280-480380-480480-4805

11111111

22222222

3333

678910111213

14151617

MXVNumber of stages

Pump size Stage casings with

bearingNumber of stages

Pump size Stage casings with

bearing

Variable parts Variable parts

MXV 25, 32, 40, 50 MXV 65, 80, 100

Vertical Multi-Stage In-Line Pumps

DesignationMXV L EI 25-205 G *

SeriesAISI 316L vesionWith frequency converter I-MATDN ports in mmRated capacity in m3/h (n ≈ 2900 rpm)Number of stages

Construction variantsspecial seal code (no code = standard seal)

threaded ports Gflanged ports Foval flange ports Owith motor (or without motor)* with no further designation = with standard motor

DesignationMXV L EI 65-3205 H1 *

SeriesAISI 316L vesionWith frequency converter I-MATDN ports in mmRated capacity in m3/h (n ≈ 2900 rpm)Number of stages

Construction variantsspecial seal code (no code = standard seal)

with support feet for horizontal installation H, variant 1with motor (or without motor)* with no further designation = with standard motor

Page 4: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

Coverage chart

MXV Vertical Multi-Stage In-Line Pumps

2 4 8 3216 481 3 5 6 7 9 10 20 40 70600

50

100

150

200

250

0m /h

l/min 30 40 50 100 1000150 200

80 90100 150

1500 2000300 400 500

3

72.936/1

5 10 20 304

m

50 10040 200 300 500400Imp. g.p.m.

ft

Q

H

25-2 32-4 40-8

50-15

65-32

80-48

100-65

100-90

H

100

200

300

400

500

700

800MXVn≈ 2900 1/min

50-20

Page 5: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

Characteristic curves and performance n ≈ 2900 rpm

H

Q

4

5

6

7

8

10

12

14

16

18

MXV 25-220

Q

η

η

3 72.983

3

kW

MXV 25-207/D

MXV 25-204/C

MXV 25-210/D

MXV 25-208/D

MXV 25-212/DMXV 25-214/DMXV 25-216/CMXV 25-218/CMXV 25-220/C

MXV 25-205/CMXV 25-206/D

HP

0,750,751,11,11,5

1,52,22,23

11

1,51,52

233444

33

445668

79,591114136159182205228

42,553

63,57485106127149170191213

44

4,74,77,47,49,29,211,411,411,4

2,32,32,72,74,34,35,35,36,66,66,6

4050

60,570,580,5101121141161181202

37,54756

65,57594112131150169188

34,543

51,5606986

103121138155173

3139

46,554,56278

93,5109124140156

2734

40,547,55468

81,595108122136

22,52834

39,545,55768

79,591102114

1721253034425159687685

Hm

m /h3

l/min

1

16,6

1,5

25

2,5

41,6

3

50

3,5

58,3

4

66,6

4,5

75

2

33,3

0

0A*A*Q

0 50

0

0.1

0.2

240

0

0

0 50

2

4

0

10

20

40

60

80

100

120

140

180

200

220

1 2 3 4

1 2 3 4

0

100

200

300

400

500

600

700

5 10 15 20U.S. g.p.m.

ft

m

20 40 60 8030 50 70m /hl/min

m /h

30

50

40

Pst

ft

NPSH

m

kW

Pst

%

230 V 400 V

Vertical Multi-Stage In-Line PumpsMXV 25-2

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosity ν= max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

Page 6: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

H

Q

45678

10

12

14

16

MXV 32-418

Q

3

72.9843

ηη

kW

0

MXV 32-407/D

MXV 32-404/D

MXV 32-410/D

MXV 32-408/D

MXV 32-412/CMXV 32-414/CMXV 32-416/DMXV 32-418/D

MXV 32-405/DMXV 32-406/D

HP

1,51,5223

344

5,55,5

1,11,11,51,52,2

2,23344

Hm

m /h3

l/min

41,551,562

72,583

104124145166187

2,5

41,6

405060

70,580,5101121141161181

3

50

36,546

55,5657493111130148167

4

66,6

34,543,552,561,57088105123140158

4,5

75

32,541

49,5586683

99,5116132149

5

83,3

27,534,5424956708498112126

6

100

2227,533,539

44,5566778

89,5100

7

116,6

14,518,522,526,53038

45,553

60,568

8

133,3

38,548586878

97,5117136156175

3,5

58,30Q

0 90

0.05

0.25

240

0

0

0 90

2

4

0

10

20

40

60

80

100

120

140

180

200

220

0

100

200

300

400

500

600

700

ft

m

2 3 4 5 6 7 850 100 150

35

45

55

10 20 30

2 3 4 5 6 7 8

0.1

0.2

Imp. g.p.m.

m /hl/min

ft

PstkW

Pst

m /h

NPSH

m

%

4,74,77,47,49,29,211,411,4

2,72,74,34,35,35,36,66,69,69,6

A*A*

230 V 400 V

455668

79,591114136159182205

MXV 32-4

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

Page 7: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

H

Q

Q

4

5

6

7

8

10

11

13

15

17

MXV 40-819

3

3 72.392

η η

kW

MXV 40-807/C

MXV 40-804/D

MXV 40-810/D

MXV 40-808/C

MXV 40-811/DMXV 40-813/CMXV 40-815/CMXV 40-817/CMXV 40-819/C

MXV 40-805/DMXV 40-806/D

HP

23344

5,55,57,57,510

1,52,22,233

44

5,55,57,5

7,5 10

Hm

m /h3

l/min

43475971

8395

119131155179202

226

54657687

109119141163184

5

83,3

4253637485

106116138159180

6

100

4050596979

99109129149168

8

133,3

3747566675

94103122141159

9

150

3443516069

8694111128145

10

166,6

3038455360

758398113128

11

183,3

2632394551

64718496

109

12

200

2126313642

5257687889

13

216,6

4151627282

103113134154175195201206 188 178 162 143 122 99

7

116,6

0

0Q

0 140

0

0.2

0.4

240

0

0

00

2

4

0

10

20

40

60

80

100

120

140

180

200

220

0

100

200

300

400

500

600

700

ft

m

50

70

60

ft

2 4 6 8 10 12

10 20 30 40 50Imp. g.p.m.

50 100 150 200

142 4 6 8 10 12

m /hl/min

m /h

Pst

m

NPSH

%

Pst

kW

7,49,29,211,411,4

4,35,35,36,66,69,69,610,910,914,314,3

A*A*

230 V 400 V

MXV 40-8

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

Page 8: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

H

Q

Q0 24

0

0.6

1.0

280

0

0

20

40

60

80

100

120

140

180

200

220

4 8 200

100

200

300

400

500

600

700

25 50 75Imp. g.p.m.

ft

m

100 200 300 400150 250 350m /h

40

80

60

Pst

kW%

0.2

240800

0 4 8

12

12

16

16 20m /h0

4

NPSH

m

8

10

0

ft

20

0

0

0 25 50 75Imp. g.p.m.

m /hl/min

24

260

900

MXV 50-1501MXV 50-1502MXV 50-1503MXV 50-1504MXV 50-1505MXV 50-1506MXV 50-1507MXV 50-1508MXV 50-1509MXV 50-1510MXV 50-1511MXV 50-1512MXV 50-1513MXV 50-1514MXV 50-1515MXV 50-1516MXV 50-1517

1,11,52,234

5,55,57,57,57,59,29,21111111515

1,5234

5,57,57,5101010

12,512,51515152020

9,519,831,543,054,063,073,58697105116132143154165174185

8,417,828,639,549,557,567,0788895105121131141151159169

7,015,425,135,044,050,559,069778391107116125134140149

5,512,721,030,037,542,549,5586569769198

106113119126

10,321,433,946,057,568,079,592104114125141153165177186198

12,024,638,652,065,078,091,5105118130143159173186199211224

14,027,943,658,072,585,099,0115129141155173188202217230245

11,623,837,350,563,075,588,0101114126138155167180193204217

11,022,735,848,560,572,084,097110121133149161173186196209

3,69,516,324,030,033,539,0455154597278849094100

2,74,35,36,69,610,910,914,314,314,318,518,521,521,521,527,327,3

4,77,49,211,4

HPkW

Hm

m /h3

l/min

8

133,3

10

166,6

14

233

16

266

18

300

20

333

22

366

24

400

12

200

0

0Q

3

3 72.937

ηη

kWA*A*

230 V 400 V

1110

9

8

7

6

5

4

3

2

1

1213

14

15

16

MXV 50-1517

Pst

MXV 50-15

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

Page 9: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

H

Q

Q0 28

0

0.6

1.0

280

0

0

20

40

60

80

100

120

140

180

200

220

4 8 200

100

200

300

400

500

600

700

25 50 75Imp. g.p.m.

ft

m

100 200 300150 250 350m /h

40

80

60

Pst

kW

Pst

%

0.2

240800

0 4 8

12

12

16

16 20m /h0

4

NPSH

m

8

10

0

ft

20

0

0

0 25 50 75Imp. g.p.m.

m /hl/min

28

24

24

260

900

80

400 450

MXV 50-2001MXV 50-2002MXV 50-2003MXV 50-2004MXV 50-2005MXV 50-2006MXV 50-2007MXV 50-2008MXV 50-2009MXV 50-2010MXV 50-2011MXV 50-2012MXV 50-2013MXV 50-2014MXV 50-2015MXV 50-2016MXV 50-2017

1,12,234

5,57,57,59,29,2111115151515

18,518,5

1,534

5,57,51010

12,512,51515202020202525

10,723,335,448,561,073,085,097114127140151164177189205217

9,821,732,945,557,068,580,091108120132143154166178193205

8,719,830,042,052,562,573,083

100111122132143154165179190

7,317,526,537,546,555,564,5748999109118128138148161172

11,524,537,551,064,076,589,5102120133146158171185198214227

13,027,041,456,070,084,098,0112130144159172186201215232246

15,530,746,562,578,092,0

107,0122142158173188204219235251267

12,626,340,454,568,082,095,5109127141155168182196210227241

12,125,539,153,066,079,593,0106124137151164177191205221235

5,814,722,532,040,047,055,063778694

103111120128140149

4,011,718,026,032,537,544,050637178849199

106116124

2,75,36,69,610,914,314,318,518,521,521,527,327,327,327,33434

4,79,211,4

HPkW

Hm

m /h3

l/min

10

166,6

14

233

16

266

18

300

20

333

22

366

24

400

26

433

28

466

12

200

0

0Q

3

3 72.937

ηη

kWA*A*

230 V 400 V

11

10

9

8

7

6

5

4

3

2

1

12

13

14

15

16

MXV 50-2017

MXV 50-20

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

Page 10: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

2943,558,57387102116130145174

2740,554,56882

95,5109122136163

24,53750

62,575

87,5100112125150

2233,545

56,567,57990101112135

3046617792

107123138154185

34516986103121138155172207

3755,575

93,5112131150168187225

3249

65,582

98,5115131148164197

3147,563,579,595,5111127143159191

1725,53544

52,561,57079

87,5105

MXV 65-3207/D

MXV 65-3204/C

MXV 65-3202/DMXV 65-3203/C

MXV 65-3209/E

MXV 65-3208/D

MXV 65-3210/EMXV 65-3212/D

MXV 65-3205/DMXV 65-3206/D

HPkW

45,57,51111

1515

18,518,5

5,57,5101515

202025253022

Hm

m /h3

l/min

15

250

21

350

27

450

30

500

33

550

36

600

39

650

44

733

24

400

0

0Q

72.9743

3

H

Q

MXV 65-3212

10

9

8

7

6

5

4

3

2

Q

0 500

1

2

240

0

0

20

40

60

80

100

120

140

180

200

220

10 20 30 400

100

200

300

400

500

600

700

50 100 150Imp. g.p.m.

ft

m

200 400 600 800300 500 700m /hl/min

40

80

60

η Pst

kW

Pst

%

η

0

10

0 5010 20 30 40m /h0

4

NPSHft

m

0

20

8

9,610,914,321,521,527,327,3343441

A*A*

230 V 400 V

MXV 65-32

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

Page 11: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

MXV 80-48

72.1035

ft

m

m /hl/min

ft

Pst

kWPst

m /h

NPSH

m

H

Q

Q

3

3

η%η

MXV 80-4801/DMXV 80-4802/CMXV 80-4803/CMXV 80-4804/DMXV 80-4805/DMXV 80-4806/DMXV 80-4807/EMXV 80-4808/D

HPkW

45,57,5111515

18,522

5,57,5101520202530

1326,54055

68,58296

109

1224,537

51,564,577,590

103

10,722344860728496

9,520314455667788

1529,544607590105120

1836547290

108126144

2040,56181

101121142162

1734,5516986103120137

1632,548658197113129

Hm

m /h3

l/min

21

350

27

450

33

550

45

750

48

800

51

850

54

900

715,524,5354453

61,570,5

60

1000

39

650

0

0Q

4

0

2

3

1

70

80

50

7

6

5

4

3

2

1000900

200

50

6010 30

10 30

160

ft

50

60

104

6

040200

1

60

40

MXV 80-4808

700500300 800600400200

Imp. g.p.m. 15010050

600

500

400

300

200

100

04020

180

200

140

120

100

80

60

40

20

0

0

2

0

0

9,610,914,321,527,327,33441

A*A*

230 V 400 V

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

Page 12: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

MXV 100-65

0

0

2

4

6

8

4

108

12

072.9743

3

H

Q

MXV 100-65

Q

0 1000

240

0

0

20

40

60

80

100

120

140

180

200

220

20 40 60 800

100

200

300

400

500

600

700

100 200 300Imp. g.p.m.

ft

m

400 800 1200 1600600 1000 1400m /hl/min

20

100

60

40

80% η

0 10020 40 60 80m /h

ft

kW

PstPst

Pst R

NPSH

m

8-2R

7

8

7-2R

6

6-2R

5

5-2R

4

4-2R

3

3-2R

2

1

2-2R

MXV(L) 100-6501MXV(L) 100-6502-2RMXV(L) 100-6502MXV(L) 100-6503-2RMXV(L) 100-6503/AMXV(L) 100-6504-2R/AMXV(L) 100-6504MXV(L) 100-6505-2RMXV(L) 100-6505MXV(L) 100-6506-2RMXV(L) 100-6506MXV(L) 100-6507-2RMXV(L) 100-6507MXV(L) 100-6508-2RMXV(L) 100-6508

HPkW

5,57,51115

18,518,5223030303737454545

7,51015202525304040405050606060

22,53346

56,56979

92,5104116127139150163174186

2231455467

75,590,5101114123136145159168181

202541

46,561,5668390

105110125130147152167

18,522

38,542

57,560,57883

98,5102117120138141157

23,53548

59,571,583

96,5109121133145156169181193

2537,551

63,576

88,5102116129141154166180193206

2839

56,567,584,595,5113125142153170181199210227

24,536,549,5627486

100113125137150162175188200

2435,548,560,572,584

97,5110122134147158172184196

Hm

m /h3

l/min

30

500

36

600

42

700

54

900

60

1000

72

1200

78

1300

16,517,534,535,551,55270

72,588,589,5105106124125141

85

1417

45

750

0

0Q

10,914,321,527,33434415454546464777777

A*

400 V

η

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

Page 13: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

MXV 100-90

72.1035

ft

m

m /hl/min

ft

Pst

Pst RPst

kW

m /h

NPSH

m

H

Q

Q

3

3

η%η

MXV(L) 100-9001-1RMXV(L) 100-9001MXV(L) 100-9002-2RMXV(L) 100-9002MXV(L) 100-9003-2R/AMXV(L) 100-9003MXV(L) 100-9004-2RMXV(L) 100-9004MXV(L) 100-9005-2RMXV(L) 100-9005MXV(L) 100-9006-2RMXV(L) 100-9006

HPkW

5,57,51115

18,522303037374545

7,51015202530404050506060

17,523,536,547,559,572

85,596,5109120134144

16,5223445566981

92,5103114127138

13,520

28,541

48,562,571,58492

104113126

1017

21,535

38,553,559727689

94,5108

1924

38,549

62,57489

99,5113123138149

2127,543

55,570,584

100112127140156169

2230,544,562

75,593,5108125139156170188

20,526425368

80,597108123134150161

2025,541

51,566,578

94,5105120130146157

Hm

m /h3

l/min

45

750

54

900

60

1000

78

1300

85

1417

96

1600

108

1800

6,513,515

28,528,54446606074

75,589,5

118

1967

72

1200

0

0Q

8

10

0

4

6

2

80

100

40

20001800

400

100

12020 60

20 60

160

ft

100

120

108

12

080400

60

20

MXV 100-90

14001000600 16001200800400

Imp. g.p.m. 300200100

600

500

400

300

200

100

08040

180

200

140

120

100

80

60

40

20

0

0

4

0

0

10,914,321,527,33441545464647777

A*

400 V

6

6-2R

5-2R

4-2R

2-2R

1-1R

5

4

3

3-2R

2

1

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

Page 14: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

MXV25-232-440-8

ØN.

d

43

GDN

30,231,233,334,337,238,243,144,154,656,657,631,232,236,237,241,142,152,654,657,858,836,240,141,150,651,655,856,877,378,385,786,7

MXV (F)MXV (G)

(5) (5)

MXV 25-204/CMXV 25-205/CMXV 25-206/DMXV 25-207/DMXV 25-208/DMXV 25-210/DMXV 25-212/DMXV 25-214/DMXV 25-216/CMXV 25-218/CMXV 25-220/C

kW DN afG a h1 f AD n1 n2 m1 m2HP0,750,751,11,11,51,52,22,2333

11

1,51,52233444

M80 V1M80 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1M100 V1M100 V1M100 V1

2525252525252525252525

250250250250250250250250250250250

G1G1G1G1G1G1G1G1G1G1G1

215215215215215215215215215215215

7575757575757575757575

372396420444478526574622680728776

210210210210210210210210210210210

180180180180180180180180180180180

150150150150150150150150150150150

100100100100100100100100100100100

12,512,512,512,512,512,512,512,512,512,512,5

MXV 32-404/DMXV 32-405/DMXV 32-406/DMXV 32-407/DMXV 32-408/DMXV 32-410/DMXV 32-412/CMXV 32-414/CMXV 32-416/DMXV 32-418/D

1,11,11,51,52,22,23344

1,51,5223344

5,55,5

M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1M100 V1M100 V1M112 V1M112 V1

32323232323232323232

250250250250250250250250250250

G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4

215215215215215215215215215215

75757575757575757575

372396430454478526584632680728

210210210210210210210210210210

180180180180180180180180180180

150150150150150150150150150150

100100100100100100100100100100

12,512,512,512,512,512,512,512,512,512,5

MXV 40-804/DMXV 40-805/DMXV 40-806/DMXV 40-807/CMXV 40-808/CMXV 40-810/DMXV 40-811/DMXV 40-813/CMXV 40-815/CMXV 40-817/CMXV 40-819/C

M90 V1M90 V1M90 V1M100 V1M100 V1M112 V1M112 V1M132 V1M132 V1M132 V1M132 V1

4040404040404040404040

280280280280280280280280280280280

G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2

225225225225225225225225225225225

8080808080808080808080

411441471511541601631711771831891

M fM P200200200200200200200200250250250200200200200200200250250250250200200200250250250250300300300300

246246246246246246246246246246246

215215215215215215215215215215215

190190190190190190190190190190190

130130130130130130130130130130130

1414141414141414141414

ISO 228 s

MXV (G)(4)kg

1819202122232526293132192021222324272930312122232526282935363839

(5)kg(6) (6)

mm

1 1 / 4

1 1 / 2

115140

DEDN

150

85100

DK

110

6576

DG

84

141919

2532

DN

40

1

444

GISO 228

253240

DN

DG

DK

DE

G

h1

f

a

P

G

20

(25

MX

4 4

0-8)

h1

af

M

AD

DN

s

m2

m1

n2 n1

fM

DN

(3)

(2)(2)3.93.011 3.93.011/1

(1)(1)

EN 1092-1 PN 25 - 40

127,5127,5127,5127,5127,5127,5127,5127,5137,5137,5137,5127,5127,5127,5127,5127,5127,5137,5137,5137,5137,5127,5127,5127,5137,5137,5137,5137,5159,5159,5159,5159,5

255255255255255255295295311311311255255255255295295311311311311255295295311311311311339339339339

627651675699733781869917991

10391087627651685709773821895943991

1039666736766822852912942

1050111011701230

1,52,22,23344

5,55,57,57,5

23344

5,55,57,57,51010

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

Pump

(1) Filling(2) Draining(3) Standard position of terminal box.

(for other positions rotate motor through 90° or 180°)

Motor threadedports

flangedports

withoutmotor

withmotor

Counterflanges in stainless steel

Flanges

(4) MXV (F) = MXV (G) + 1kg (5) With standard motor (6) Net weight

Holes

Page 15: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

MXV 50-1550-20

MXV 50-1501MXV 50-1502MXV 50-1503MXV 50-1504MXV 50-1505MXV 50-1506MXV 50-1507MXV 50-1508MXV 50-1509MXV 50-1510MXV 50-1511MXV 50-1512MXV 50-1513MXV 50-1514MXV 50-1515MXV 50-1516MXV 50-1517MXV 50-2001MXV 50-2002MXV 50-2003MXV 50-2004MXV 50-2005MXV 50-2006MXV 50-2007MXV 50-2008MXV 50-2009MXV 50-2010MXV 50-2011MXV 50-2012MXV 50-2013MXV 50-2014MXV 50-2015MXV 50-2016MXV 50-2017

kW DN a h1 f

mm

AD m4HP1,11,52,234

5,55,57,57,57,59,29,211111115151,12,234

5,57,57,59,29,2111115151515

18,518,5

1,5234

5,57,57,5101010

12,512,515151520201,534

5,57,51010

12,512,51515202020202525

M80 V1M90 V1M90 V1M112 V1M112 V1M132 V1M132 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M80 V1M90 V1M100 V1M112 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1

50505050505050505050505050505050505050505050505050505050505050505050

300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300

ao

200200200200200200200200200200

200200200200200200200200200200

90909090909090909090909090909090909090909090909090909090909090909090

438438486534582693741789837885963

101110591107115512031251438438486521645693741819867915963

101110591107115512031251

127,5127,5127,5137,5137,5159,5159,5159,5159,5159,5186186186186186186186

127,5127,5137,5137,5159,5159,5159,5186186186186186186186186206206

M

255295295311311339339339339339413413459459459484484255295311311339339339413413459459484484484484538538

fM

693733781845893

103210801128117612241376142415181566161416871735693733797832984

103210801232128013741422149515431591163917411789

P

200200200250250300300300300300350350350350350350350200200250250300300300350350350350350350350350350350

MXV (5)kg (7)

27,427,929,431,833,344,345,747,248,650,157,859,360,762,263,765,166,627,427,930,331,842,844,345,753,554,956,457,859,360,762,263,765,166,6

24,625,126,629,030,541,542,944,445,847,3

24,625,127,629,040,041,542,950,752,153,6

349349397445493541589637685733781829877925973

10211069349349397445493541589637685733781829877925973

10211069

165

DEDN

DN 50

125

DK

499

DG

1950

EN 1092-2 PN 25

(6)kg (7)

40,743,147,557,461,186,688,094,996,397,8

115,8117,3136,7138,2139,7167,1168,640,746,055,959,685,192,093,4

111,5112,9132,4133,8161,3162,7164,2165,7

--

37,940,344,754,658,383,885,292,193,595,0

37,943,253,256,882,389,290,6

129,6

N. Ø

(6)(8)

(8) (8)

(6)

4.93.210/2

h1

fM

f

M

AD

DN

DN

aao 25

250

215

196

13

130

100

130

DN 50

N. 2 FORI M 12

40

m4

200

15

170

130

Ø15

G 3/8(2)

G 3/8(3)

G 3/8(3)

G 3/8(2)

G 1/4(1)

G 1/4(1)

G 1/4(1)

G 1/4(1)

(4)

P

DN

50

G 2

34

d

DN

DG

DK

DE

Pump Motor

withoutmotor

withmotor

(1) Filling and air vent(2) Air vent suction side(3) Draining(4) Standard position of terminal box.

(for other positions rotate motor through 90° or 180°)(5) MXV (L) : + 3 kg - MXV (H) : + 3 kg(6) With standard motor(7) Net weight(8) Oval flanges MXV (O)

Flanges EN 1092-2 PN 25

Holes

Oval Counterflanges

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

Page 16: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

kW DN a h1 f

mm

AD m4HP

137,5159,5159,5186186186186206206206

137,5159,5159,5186186186206206

MXV 65-3202/D MXV 65-3203/C MXV 65-3204/C MXV 65-3205/D MXV 65-3206/D MXV 65-3207/D MXV 65-3208/D MXV 65-3209/E MXV 65-3210/E MXV 65-3212/D MXV 80-4801/D MXV 80-4802/C MXV 80-4803/C MXV 80-4804/D MXV 80-4805/D MXV 80-4806/D MXV 80-4807/E MXV 80-4808/D

45,57,511111515

18,518,5224

5,57,5111515

18,522

5,57,510151520202525305,57,5101520202530

M112 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M180 V1M112 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1

656565656565656565658080808080808080

320320320320320320320320320320320320320320320320320320

105105105105105105105105105105105105105105105105105105

407473519595641687733779825917411466527618680741802864

M

311339339459459484484538538538311339339459484484538538

fM

7188128581054110011711217129013631455

72280586610771164122513631402

P

250300300350350350350350350350250300300350350350350350

MXV (5)kg (7)

455153626466687072754551546466697274

334380426472518564610656702794338373434495557618679741

DEDN

DN 50 DN 65-80

185

DK

145 8

DG

118 1965

200 160 8132 1980

EN 1092-2 PN 25 - 40

(6)kg (7)

72,893,3

100,7138140168170

--

204

72,893,3

101,7140168171

-203

N. Ø

G 1/8(2)

G 3/8(3)

(6) (6)

G 3/8(1)

G 3/8(3)

AD

(4) M

f

P

35

220

260

220

260

14

fM

DN

DKDG

DE

DN

DKDG

DE

DNDN

h1

a4.93.210/2

220

260

Ø14200

15

43

m4

G 3/8 (3)

G 3/8 (1) (2) (4)

4.93.210/3

MXV 65-3280-48

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

Pump

(1) Filling and air vent(2) Air vent suction side(3) Draining

Motorwithoutmotor

withmotor

Flanges

(4) Standard position of terminal box. (for other positions rotate motor through 90° or 180°) (5) MXV (L) : + 3 kg (6) With standard motor (7) Net weightMXV (H) : + 3 kg

Holes

Page 17: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

Dimensions and weights

MXV 100-65100-90

MXV 100-6501MXV 100-6502-2RMXV 100-6502MXV 100-6503-2RMXV 100-6503/AMXV 100-6504-2R/AMXV 100-6504MXV 100-6505-2RMXV 100-6505MXV 100-6506-2RMXV 100-6506MXV 100-6507-2RMXV 100-6507MXV 100-6508-2RMXV 100-6508MXV 100-9001-1RMXV 100-9001MXV 100-9002-2RMXV 100-9002MXV 100-9003-2R/AMXV 100-9003MXV 100-9004-2RMXV 100-9004MXV 100-9005-2RMXV 100-9005MXV 100-9006-2RMXV 100-9006

kW f m2m1n2n1 M

mm

fmPN

5,57,51115

18,518,52230303037374545455,57,51115

18,522303037374545

HP

7,510152025253040404050506060607,51015202530404050506060

161616161616161616162525252525161616161616161616162525

M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1M200 V1M200 V1M200 V1M200 V1M200 V1M225 V1M225 V1M225 V1M132 V1M132 V1M160 V1M160 V1M160 V1M180 V1M200 V1M200 V1M200 V1M200 V1M225 V1M225 V1

190190190190190190190190190190190190190190190199199199199199199199199199199199199

240240240240240240240240240240240240240240240260260260260260260260260260260260260

265265265265265265265265265265265265265265265280280280280280280280280280280280280

316316316316316316316316316316316316316316316341341341341341341341341341341341341

7378298499419411033103311311131122312231315131514071407737737849849941941103810381131113112231223

a

365365365365365365365365365365365365365365365380380380380380380380380380380380380

339339459484538538538611611611611611708708708339339459484538538611611611611708708

107611681308142514791571157117421742183418341926202321152115107610761308133314791479164916491742174219311931

AD

159,5159,5186186206206206315315315315315338338338

159,5159,5186186206206315315315315338338

P

300300350350350350350400400400400400450450450300300350350350350400400400400450450

8185,588,59393

97,598

105,5105,5110110

114,5117,512212282,582,589899393

100100104104

110,5110,5

123,3127,8164,5195

--

227330,5330,5335360

364,5432,5437437

124,8124,8165191

-222325325354354

425,5425,5

SizeMXVkg (5)

(4)kg (5)

DN

DK

DE

(4)

230

DEDN

255

180

DK

190

8

8

16

PN

25

19

23

100

100

EN 1092-2

n2

m2

m1

n1

N. 4 x Ø15

DN DN

AD

M

fM

140

a

45

f

P

(1)(1)

(2)

(3)

N. Ø

Pump Motorwithoutmotor

withmotor

(3) Standard position of terminal box. (for other positions rotate motor through 90° or 180°) (4) With standard motor (5) Net weight

Flanges

Holes

Vertical Multi-Stage In-Line Pumps

(1) Filling and air vent(2) Draining

Page 18: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

ØN.

d

43

GDN

36,637,639,740,743,844,850,651,662,164,165,137,638,642,843,848,649,660,162,165,866,842,847,648,658,659,663,864,885,386,3100,5101,5

MXV EI (F)MXV EI (G)

MXV EI 25-204/CMXV EI 25-205/CMXV EI 25-206/DMXV EI 25-207/DMXV EI 25-208/DMXV EI 25-210/DMXV EI 25-212/DMXV EI 25-214/DMXV EI 25-216/CMXV EI 25-218/CMXV EI 25-220/C

kW DN afG a h1 f AD n1 n2 m1 m2HP0,750,751,11,11,51,52,22,2333

11

1,51,52233444

M80 V1M80 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1M100 V1M100 V1M100 V1

2525252525252525252525

250250250250250250250250250250250

G1G1G1G1G1G1G1G1G1G1G1

215215215215215215215215215215215

7575757575757575757575

372396420444478526574622680728776

210210210210210210210210210210210

180180180180180180180180180180180

150150150150150150150150150150150

100100100100100100100100100100100

12,512,512,512,512,512,512,512,512,512,512,5

MXV EI 32-404/DMXV EI 32-405/DMXV EI 32-406/DMXV EI 32-407/DMXV EI 32-408/DMXV EI 32-410/DMXV EI 32-412/CMXV EI 32-414/CMXV EI 32-416/DMXV EI 32-418/D

1,11,11,51,52,22,23344

1,51,5223344

5,55,5

M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1M100 V1M100 V1M112 V1M112 V1

32323232323232323232

250250250250250250250250250250

G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4

215215215215215215215215215215

75757575757575757575

372396430454478526584632680728

210210210210210210210210210210

180180180180180180180180180180

150150150150150150150150150150

100100100100100100100100100100

12,512,512,512,512,512,512,512,512,512,5

MXV EI 40-804/DMXV EI 40-805/DMXV EI 40-806/DMXV EI 40-807/CMXV EI 40-808/CMXV EI 40-810/DMXV EI 40-811/DMXV EI 40-813/CMXV EI 40-815/CMXV EI 40-817/CMXV EI 40-819/C

M90 V1M90 V1M90 V1M100 V1M100 V1M112 V1M112 V1M132 V1M132 V1M132 V1M132 V1

4040404040404040404040

280280280280280280280280280280280

G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2

225225225225225225225225225225225

8080808080808080808080

411441471511541601631711771831891

M fM P200200200200200200200200250250250200200200200200200250250250250200200200250250250250300300300300

246246246246246246246246246246246

215215215215215215215215215215215

190190190190190190190190190190190

130130130130130130130130130130130

1414141414141414141414

ISO 228 s

MXV EI (G)(4)

kg (5)

mm

1 1 / 4

1 1 / 2

115140

DEDN

150

85100

DK

110

6576

DG

84

141919

2532

DN

40

1

444

GISO 228

253240

DN

DG

DK

DE

G

h1

f

a

P

G

20

(25

MX

V E

I 40

-8)

h1

af

M

AD

DN

s

m2

m1

n2 n1

AS

AG

fM

DN

(3)

(2)(2)3.93.011 3.93.011/1

(6)(1)

EN 1092-1 PN 25 - 40

286286286286286286286286294294294286286286286286286294294294294286286286294294294294321321368368

AS105105105105105105118118118118118105105105105118118118118118118105118118118118118118118118153153

AG190190190190190190210210210210210190190190190210210210210210210190210210210210210210210210281281

255255255255255255295295311311311255255255255295295311311311311255295295311311311311339339339339

6276516756997337818699179911039108762765168570977382189594399110396667367668228529129421050111011701230

1,52,22,23344

5,55,57,57,5

23344

5,55,57,57,51010

MXV EI25-232-440-8

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

Pump

(1) Filling(2) Draining(3) Standard position of I-MAT

(for other positions rotate motor through 90° or 180°)(4) MXV EI (F) = MXV EI (G) + 1kg (5) Net weight(6) Pressure transducer

Motor threadedports

flangedports

Counterflanges in stainless steel

Holes

Flanges in accordanceEN 1092-2 PN 25 - 40

Page 19: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

MXV EI 50-1550-20

MXV EI 50-1501MXV EI 50-1502MXV EI 50-1503MXV EI 50-1504MXV EI 50-1505MXV EI 50-1506MXV EI 50-1507MXV EI 50-1508MXV EI 50-1509MXV EI 50-1510MXV EI 50-1511MXV EI 50-1512MXV EI 50-1513MXV EI 50-1514MXV EI 50-1515MXV EI 50-1516MXV EI 50-1517MXV EI 50-2001MXV EI 50-2002MXV EI 50-2003MXV EI 50-2004MXV EI 50-2005MXV EI 50-2006MXV EI 50-2007MXV EI 50-2008MXV EI 50-2009MXV EI 50-2010MXV EI 50-2011MXV EI 50-2012MXV EI 50-2013MXV EI 50-2014MXV EI 50-2015MXV EI 50-2016MXV EI 50-2017

kW DN a h1 f

mm

AD m4HP1,11,52,234

5,55,57,57,57,59,29,211111115151,12,234

5,57,57,59,29,2111115151515

18,518,5

1,5234

5,57,57,5101010

12,512,515151520201,534

5,57,51010

12,512,51515202020202525

M80 V1M90 V1M90 V1

M112 V1M112 V1M132 V1M132 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M80 V1M90 V1

M100 V1M112 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1

50505050505050505050505050505050505050505050505050505050505050505050

300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300

ao

200200200200200200200200200200

200200200200200200200200200200

90909090909090909090909090909090909090909090909090909090909090909090

438438486534582693741789837885963

101110591107115512031251438438486521645693741819867915963

101110591107115512031251

286286286294294321321368368368393393393393393471471286286294294321368368393393393393471471471471491491

M

255295295311311339339339339339413413459459459484484255295311311339339339413413459459484484484484538538

AG

190190210210210210210281281281281281281281281350350190210210210210281281281281281281350350350350350350

AS

105105118118118118118153153153153153153153153190190105118118118118153153153153153153190190190190190190

fM

693733781845893

103210801128117612241376142415181566161416871735693733797832984

103210801232128013741422149515431591163917411789

P

200200200250250300300300300300350350350350350350350200200250250300300300350350350350350350350350350350

349349397445493541589637685733781829877925973

10211069349349397445493541589637685733781829877925973

10211069

165

DEDN

DN 50

125

DK

499

DG

1950

EN 1092-2 PN 25

(5)kg (6)

47,149,754,564,969,194,696,0

109,7111,1112,6130,6132,1151,5153,0154,5202,1203,647,153,063,467,693,1

106,8108,2126,3127,7147,2148,6196,3197,7199,2200,7207,1208,6

44,346,951,762,166,391,893,2

106,9108,3109,8

44,350,260,764,890,3

104,0105,4

144,4

N. Ø

(8)

(8)

4.93.210/2

f

130

h1

fM

M

DN

DN

aao 25

250

215

196

13

130

100DN 50

N. 2 FORI M 12

40

m4

200

15

170

130

Ø15

G 3/8(2)

G 3/8(2)

G 3/8(3)

G 1/4(1)

G 1/4(1)

P

DN

50

G 2

34

AD

(7)(4)

AS

AG

(4)

d

DN

DG

DK

DE

(1) Filling and air vent(2) Air vent suction side(3) Draining(5) MXV EI (L) : + 3 kg

MXV EI (H) : + 3 kg(6) Net weight(7) Pressure transducer(8) Oval flanges MXV (O)

(4) Standard position of I-MAT. (for other positions rotate motor through 90° or 180°)

Pump Motor

Flanges EN 1092-2 PN 25

Holes

OvalCounterflanges

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

Page 20: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

MXV EI Vertical Multi-Stage In-Line Pumps

MXV EI

(5)kg (6)

DEDN

DN 50 DN 65-80

185

DK

145 8

DG

118 1965

200 160 8132 1980

EN 1092-2 PN 25 - 40

N. Ø

MXV EI 65-3202/DMXV EI 65-3203/CMXV EI 65-3204/CMXV EI 65-3205/DMXV EI 65-3206/DMXV EI 65-3207/DMXV EI 65-3208/DMXV EI 65-3209/EMXV EI 65-3210/EMXV EI 65-3212/DMXV EI 80-4801/DMXV EI 80-4802/CMXV EI 80-4803/CMXV EI 80-4804/DMXV EI 80-4805/DMXV EI 80-4806/DMXV EI 80-4807/EMXV EI 80-4808/D

kW DN a h1 f

mm

AD m4HP4

5,57,511111515

18,518,5224

5,57,5111515

18,522

5,57,510151520202525305,57,5101520202530

M112 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M180 V1M112 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1

656565656565656565658080808080808080

320320320320320320320320320320320320320320320320320320

105105105105105105105105105105105105105105105105105105

407473519595641687733779825917411466527618680741802864

294321368393393471471491491491294321368393471471491491

M

311339339459459484484538538538311339339459484484538538

AG

210210281281281350350350350350210210281281350350350350

AS

118118153153153190190190190190118118153153190190190190

fM

718812858

1054110011711217129013631455722805866

10771164122513401402

P

250300300350350350350350350350250300300350350350350350

334380426472518564610656702794338373434495557618679741

80,8101,3115,5152,8154,8203205

--

23980,8

101,3116,5154,8203206

-238

DN

DKDG

DE

DN

DKDG

DE

G 1/8(2)

G 3/8(3)

G 3/8(1)

G 3/8(3)

AD

M

f

P

35

220

260

220

260

14

fM

DNDN

h1

a4.93.210/2

220

260

Ø14200

15

43

m4

G 3/8 (3)

G 3/8 (1) (2)

(4)

(7)

(4)

AS

AG

65-3280-48

Dimensions and weights

PumpMotor

Holes

Flanges in accordanceEN 1092-2 PN 25 - 40

(1) Filling and air vent(2) Air vent suction side(3) Draining(4) Standard position of I-MAT

(for other positions rotate motor through 90° or 180°)(5) MXV (L) : + 3 kg, MXV (H) : + 3 kg(6) Net weight (7) Pressure transducer

Page 21: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

kW f m2m1n2n1 M

mm

fmPNHP a AD AG ASPSize

MXV EI

kg (4)

DN

DK

DE

AS

AG

230

DEDN

225

180

DK

190

8

8

16

PN

25

19

23

100

100

EN 1092-2

n2

m2

m1

n1

N. 4 x Ø15

DN DN

AD

M

fM

140

a

45

f

P

(5)(1)(1)

(2)

(3)

MXV EI 100-6501MXV EI 100-6502-2RMXV EI 100-6502MXV EI 100-6503-2RMXV EI 100-6503/AMXV EI 100-6504-2R/AMXV EI 100-6504MXV EI 100-9001-1RMXV EI 100-9001MXV EI 100-9002-2RMXV EI 100-9002MXV EI 100-9003-2R/AMXV EI 100-9003

7,51015202525307,51015202530

5,57,51115

18,518,5225,57,51115

18,522

16161616161616161616161616

M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1M132 V1M132 V1M160 V1M160 V1M160 V1M180 V1

190190190190190190190199199199199199199

240240240240240240240260260260260260260

265265265265265265265280280280280280280

316316316316316316316341341341341341341

737829849941941

10331033737737849849941941

365365365365365365365380380380380380380

1076116813081425147915711571107610761308133314791479

339339459484538538538339339459484538538

210281281350350350350210281281350350350

3213683934714914-1491321368393471491491

118153153190190190190118153153190190190

300300350350350350350300300350350350350

131,3142,6179,3230

--

262132,8139,6179,8226

-257

N. Ø

Flanges in accordanceEN 1092-2

MXV EI Vertical Multi-Stage In-Line Pumps100-65100-90

Dimensions and weights

Pump Motor

Holes

(1) Filling and air vent(2) Draining(3) Standard position of I-MAT

(for other positions rotate motor through 90° or 180°)(4) Net weight(5) Pressure transducer

Page 22: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

Features

Vertical Multi-Stage In-Line PumpsMXV

3.93.112

MXV 25, 32, 40, 50

MXV 65, 80

3.93.029

Long Service Life with Standard MotorPump with thrust bearing without additional axial loads on the motor bearings.Any standard motor V1 design (suitable to be lifted in vertical position) can beused, of our choice or of Client’s choice.

Easy Assembly of the MotorWith the single-piece sleeve coupling the pump unit can be supplied fullyassembled also without the motor. This eliminates the risk of damage causedby shifting of the pump shaft during transportation.The motor is simply inserted in the coupling and fastened to the flange with-out the necessity for adapting the axial position of the pump shaft.

Removable mechanical SealEasy removal of the mechanical sealwithout dismantling the motor (for MXV50-15, MXV 50-20 and MXV 100 withmotors exceeding 4 KW).

Extra SafetySingle-piece coupling guard to be removed only by means of a tool, positionedaround the lantern bracket, thus avoiding accidental pushing and rubbingagainst the coupling.

Low Cost InstallationVertical construction with reduced pump height for installation in smallspaces. In-line connections to simplify the piping layout with the possibility of insertingthe pump in straight pipe-lines. Disassembly, inspection or cleaning of internal parts without removal of piping.

Robust and ReliableSingle PN 25 construction for all pump sizes.The suction and discharge nozzles arranged in-line absorb the forces of the pip-ing on the pump without the creation of distorting loads causing local friction andearly wears.The lantern brackets compact and robust design maintains a sure alignmentbetween rotating and fixed parts, reducing vibration.The upper cover design prevents entrapment of air around the mechanical seal.

Low-Noise OperationThe water filled shroud around the stages and thick external walls, worktogether for low-noise operation.Low-noise standard motor.

MXV 50-15, MXV 50-20

Page 23: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

Vertical Multi-Stage In-Line Pumps

ConstructionVertical multi-stage pumps with suction and delivery connections ofthe same diameter and arranged along the same axis (in-line).Corrosion-resistant bearing sleeves lubricated by the pumped liquid.Removal of the mechanical seal without dismantling the motor(for MXVL 50, MXVL 100 with motors exceeding 4 KW).A pump with thrust bearing and sleeve coupling for use of anystandard motor with IM V1 construction.

Version with frequency converter (on request)

ApplicationsFor water supply systems.For clean non-explosive liquids, without solid, filamentary orabrasive matter (with adaptation of sealing materials on request).A universal pump for civil and industrial use, for pressure-boostingsystems, fire-extinguishing systems, high-pressure washingplants, irrigation, agricultural uses and sport installations.

Operating conditionsTemperature of liquid: from -15 °C to +110 °C (up to +120 °Cfor MXVL 50).Operating environment temperature: up to 40 °C.Maximum permissible pressure in pump casing: 25 bar. (16 bar for pumps with oval flanges).

MotorStandard-type: 2-pole induction motor, 50 Hz (n ≈ 2900 rpm).Construction IM V1 (EN 60034-7).Motor suitable for operation with frequency converter.Classification scheme IE3 for three-phase motors.Insulation class F.Protection IP 55.three-phase with rated voltage: up to 3 kW 230/400 V;

from 4 kW 400/690 V.

MXVL 25, 32, 40, 50 MXVL 65, 80, 100

Pump with threaded ports (G) (for MXVL 25, 32, 40). Pump with flanged ports (F).Pump with oval flange ports (O) (for MXVL 50).Pump without motor.Pump with standard motor.

Variants (to be specified when ordering)

With counter-flanges in chrome-nickel steel.O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Single-phase motor 230 V, up to 2.2 kW.Other voltage ratings. Frequency 60 Hz.

Other variants (on request)

Direction of rotation: clockwise as seen from the motor.Direction of rotation: anticlockwise as seen from the motor.(clockwise as seen from the motor for MXVL 100)

Pump without motor.Pump with standard motor.

Variants (to be specified when ordering)

O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Other voltage ratings. Frequency 60 Hz. Pump with support feet for horizontal installation (H1 or H2).Support feet for horizontal installation, set. Welding counter-flanges, PN 25 (steel).

Other variants (on request)

Component Material

FlangeExternal jacketSuction casingDelivery casing Stainless SteelStage casing 1.4404 EN 10088 (AISI 316L)ImpellerLower coverUpper coverSpacer sleevePump shaft Stainless SteelPlug 1.4404 EN 10088 (AISI 316L)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic aluminaMechanical sealISO 3069 - KU Hard metal/Carbon/EPDM.

Wear ring PPS (PTFE for MXVL 40)O-rings NBR (EPDM for MXVL 50)

Materials (wetted parts)

All parts that come into contact with the liquid, including wet-endcovers, are in chrome-nickel-molybdenum stainless steel AISI 316L.

Internal parts in contact with the liquid with pump casing and uppercover in chrome-nickel-molybdenum stainless steel AISI 316L.

Component Material

Pump casing Stainless SteelUpper cover 1.4404 EN 10088 (AISI 316L)

External jacketStage casing Stainless SteelImpeller 1.4404 EN 10088 (AISI 316L)Spacer sleevePump shaft Stainless Steel (AISI 316L)(AISI 329 for MXVL 100)Plug Stainless Steel 1.4404 EN 10088 (AISI 316L)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic alumina

(Corrosion-resistant, cemented carbide for MXVL 100)Mechanical sealISO 3069 - KU

Hard metal/Carbon/EPDM

Wear ring PTFEO-rings NBR (EPDM for MXV 100)

Materials (wetted parts)

The electropumps MXVL series comply with the European Regulation no. 547/2012.

MXVL AISI 316L

Page 24: Vertical Multi-Stage In-Line Pumps Construction · Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line)

2 4 8 3216 481 3 5 6 7 9 10 20 40 70600

50

100

150

200

250

0m /h

l/min 30 40 50 100 1000150 200

80 90100 150

1500 2000300 400 500

3

72.936/1

5 10 20 304

m

50 10040 200 300 500400Imp. g.p.m.

ft

Q

H

25-2 32-4 40-8

50-15

65-32

80-48

100-65

100-90

H

100

200

300

400

500

700

800MXVn≈ 2900 1/min

50-20

Coverage chart

For characteristic curves, dimensions and weights see MXV

Vertical Multi-Stage In-Line PumpsMXVL AISI 316L

MXVL