USER'S GUIDE G9SX G9SX Flexible Safety Unit G9SX-NS Non-Contact Door Switch Controller G9SX-GS Safety Guard Switching Unit Cat.No. Z255-E1-01

Upload: others

Post on 09-Oct-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

USER'S GUIDE

G9SX

G9SX Flexible Safety Unit

G9SX-NS Non-Contact Door Switch Controller

G9SX-GS Safety Guard Switching Unit

Cat.No. Z255-E1-01

Page 2: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2G9SX USER'S GUIDE

IntroductionThis User’s Guide describes the usage of the G9SX Series-Flexible Safety Units mainly through application

examples.

Humans make mistakes and machines fail.

Therefore it is necessary to design machines and equipment based on the assumption that humans will make

mistakes and machines will fail.

Thus, a circuit configuration is required to ensure safety, even when an onsite operator makes a mistake in machine

operation or when a part of the machine fails. Flexible Safety Units, which enable various safety circuit patterns to be

configured only by simple wiring, provide the core components of such safety circuits.

Use the OMRON Flexible Safety Units in your machine and equipment to improve the safety designs and onsite

worker safety measures.

Outline of this User’s Guide

Section

1Application Examples

Introduces applications that can be configured with the G9SX.

Section

2Functions of G9SX

Describes the functions of each unit of G9SX Series.

Section

3Wiring and Setup

Describes the wiring and settings required for use.

Section

4Ratings and Specifications

Provides specifications, dimensions andterminal arrangements.

AppendixDescribes troubleshooting, accessories, and related products.

Page 3: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 3

Ordering Information

■ List of ModelsAdvanced Unit

Note: 1. The OFF-delay time can be set in 16 steps as follows: T15: 0/0.2/0.3/0.4/0.5/0.6/0.7/1/1.5/2/3/4/5/7/10/15 s T150: 0/10/20/30/40/50/60/70/80/90/100/110/120/130/140/150 s

2. The OFF-delayed output becomes an instantaneous output by setting the OFF-delay time to 0 s.3. P channel MOS FET transistor output4. PNP transistor output

Basic Unit

Note: 1. P channel MOS FET transistor output2. PNP transistor output

Non-Contact Door Switch Controller (Controllers for D40A)

Note: 1. P channel MOS FET transistor output2. The OFF-delayed output becomes an instantaneous output by setting the OFF-delay time to 0 s.3. PNP transistor output4. The OFF-delay time can be set in 16 steps as follows:

0/0.2/0.3/0.4/0.5/0.6/0.7/0.8/0.9/1.0/1.2/1.4/1.8/2.0/2.5/3.0 s

Safety Guard Switching Unit

Note: 1. The OFF-delay time can be set in 16 steps as follows: T15: 0/0.2/0.3/0.4/0.5/0.6/0.7/1/1.5/2/3/4/5/7/10/15 s

2. The OFF-delayed output becomes an instantaneous output by setting the OFF-delay time to 0 s.3. P channel MOS FET transistor output4. PNP transistor output (except for the external indicator outputs, which are P channel MOS FET transistor outputs)

Expansion Unit

Note: 1. PNP transistor output2. The OFF-delay time is synchronized to the OFF-delay time setting in the connected Unit (G9SX-AD-@, G9SX-ADA-@, G9SX-NSA@ and G9SX-GS-@).

Safety outputs (solid state) (See note 3.) Auxiliary outputs

(solid state) (See note 4.)

Logical AND connectionNo. of input channels

Max. OFF-delay time

(See note 1.)

Rated voltage

Terminal block type ModelInstantaneous

OFF-delayed (See note 2.)

Inputs Outputs

3(Semiconductor)

2(Semiconductor)

2(Semiconductor)

1(Semiconductor)

1(Semiconductor)

1 or 2 channels

15 s

24 VDC

Screw terminals G9SX-AD322-T15-RT

Spring-cage terminals G9SX-AD322-T15-RC

150 sScrew terminals G9SX-AD322-T150-RT

Spring-cage terminals G9SX-AD322-T150-RC

2(Semiconductor)

2(Semiconductor)

2(Semiconductor)

15 sScrew terminals G9SX-ADA222-T15-RT

Spring-cage terminals G9SX-ADA222-T15-RC

150 sScrew terminals G9SX-ADA222-T150-RT

Spring-cage terminals G9SX-ADA222-T150-RC

Safety outputs (solid state) (See note 1.)

Auxiliary outputs (solid state)

(See note 2.)

Logical AND connection No. of input

channelsRated voltage

Terminal block type ModelInstantaneous OFF-delayed Inputs Outputs

2(Semiconductor)

---2

(Semiconductor)0 2

1 or 2 channels

24 VDCScrew terminals G9SX-BC202-RT

Spring-cage terminals G9SX-BC202-RC

Safety outputs (See note.1) Auxiliary outputs

(See note 3.)

Logical AND connection

input

Logical AND connection

output

Max. OFF-delay time

(See note 4.)

Rated voltage

Terminal block type ModelInstantaneous

OFF-delayed (See note 2.)

2 (Semiconductor)

02

(Semiconductor)1 1

---

24 VDC

Screw terminals G9SX-NS202-RT

Spring-cage terminals G9SX-NS202-RC

2 (Semiconductor)

3.0 sScrew terminals G9SX-NSA222-T03-RT

Spring-cage terminals G9SX-NSA222-T03-RC

Safety outputs (See note 3.)Auxiliary outputs

(See note 4.)

Logical AND connection Max. OFF-delay time

(See note 1.)

Rated voltage

Terminal block type

ModelInstantaneous

OFF-delayed (See note 2.)

Inputs Outputs

2 (semiconductor) 2 (semiconductor) 6 (semiconductor) 1 (semiconductor) 1 (semiconductor) 15 s24

VDC

Screw terminals G9SX-GS226-T15-RT

Spring-cage terminals

G9SX-GS226-T15-RC

Safety outputs Auxiliary outputs(See note 1.)

OFF-delay time Rated voltage Terminal block type ModelInstantaneous OFF-delayed

4 PST-NO (contact) ---

1 (semiconductor)

---

24 VDC

Screw terminals G9SX-EX401-RT

Spring-cage terminals G9SX-EX401-RC

--- 4 PST-NO (contact) (See note 2.)Screw terminals G9SX-EX041-T-RT

Spring-cage terminals G9SX-EX041-T-RC

Page 4: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

4G9SX USER'S GUIDE

Model Number Structure

■ Model Number Legend

1. Functions

AD/ADA :Advanced Unit

BC :Basic Unit

GS :Safety Guard Switching Unit

NS/NSA :D40A Controller

EX :Expansion Unit

2. Output Configuration (Instantaneous Safety Outputs)

0 : None

2 : 2 outputs

3 : 3 outputs

4 : 4 outputs

3. Output Configuration (OFF-delayed Safety Outputs)

0 : None

2 : 2 outputs

4 : 4 outputs

4. Output Configuration (Auxiliary Outputs)

1 : 1 output

2 : 2 outputs

6 : 6 outputs

5. Max. OFF-delay Time

Advanced Unit

T15 : 15 s

T150 : 150 s

Basic Unit

No indicator : No OFF delay

Safety Guard Switching Unit

T15 : 15 s

D40A Controller

T03 : 3 s

Expansion Unit

No indicator : No OFF delay

T : OFF delay

6. Terminal Block Type

RT : Screw terminals

RC : Spring-cage terminals

1 2 3 4 5 6

G9SX - @@@@@@ - @@@ - @@

Page 5: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 5

CONTENTS

Section

1Application Examples 7

1. Partial control of machine 8

1-1 Parts Processing Machine 8

1-2 Machining Center 11

1-3 Semiconductor Manufacturing Equipment 15

1-4 Machine Tool 17

2. Using Non-contact Door Switch 20

2-1 Pick and Place Machine 20

2-2 Small Assembly System 22

3. Coordinated operation of worker and machine

25

3-1 Manufacturing Automotive Parts Using Semi-automatic Processing 25

4. Safety Measures for limited operations 28

4-1 Manufacturing Flat-panel Displays (Maintenance) 28

4-2 Machining Center (Enabling Switch) 31

4-3 LCD Manufacturing (Guard Lock Control) 34

Section

2Functions of G9SX 37

1. Function list of G9SX-series 38

2. Functions of each Unit 39

2-1 Basic Unit 39

2-2 Advanced Unit 40

2-3 Non-Contact Door Switch Controller 42

2-4 Safety Guard Switching Unit 44

2-5 Expansion Unit 48

Page 6: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

CONTENTS

6G9SX USER'S GUIDE

Section

3Wiring and Setup 51

1. I/O Terminals 52

1-1 Basic Unit 52

1-2 Advanced Unit 53

1-3 Non-contact Door Switch Controller 54

1-4 Safety Guard Switching Unit 55

1-5 Expansion Unit 56

2. Functions, Wiring and Settings 57

2-1 Logical AND Connection 57

2-2 Response Time and Operation Time 60

2-3 Reset Mode 62

2-4 Cross Fault Detection 63

2-5 Connecting Safety Sensors and the G9SX 64

2-6 OFF-delay Time 65

2-7 Non-contact Door Switch 66

2-8 Switching Mode 67

2-9 External Indicator Fault Diagnosis 68

2-10 Connecting Expansion Units 69

2-11 Confirming Settings 70

Section

4Ratings and Specifications 71

1. Ratings 72

1-1 Advanced Unit/Basic Unit 72

1-2 Non-contact Door Switch Controller 73

1-3 Safety Guard Switching Unit 74

1-4 Expansion Unit 75

2. Characteristics 76

2-1 Advanced Unit/Basic Unit 76

2-2 Non-contact Door Switch Controller 77

2-3 Safety Guard Switching Unit 78

2-4 Expansion Unit 79

3. Dimensions and Terminal arrangements 80

3-1 Advanced Unit 80

3-2 Basic Unit 80

3-3 Non-contact Door Switch Controller 81

3-4 Safety Guard Switching Unit 81

3-5 Expansion Unit 82

Appendix 83

1. Troubleshooting 84

2. Logical AND Connections 91

3. Accessories and Related Products 93

Precautions 95

Page 7: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 7

Ap

plicatio

n E

xamp

lesS

ection

1Section 1

Application Examples

1. Partial control of machine 8

1-1 Parts Processing Machine 8

1-2 Machining Center 11

1-3 Semiconductor Manufacturing Equipment 15

1-4 Machine Tool 17

2. Using Non-contact Door Switch 20

2-1 Pick and Place Machine 20

2-2 Small Assembly System 22

3. Coordinated operation of worker and machine

25

3-1 Manufacturing Automotive Parts Using Semi-automatic Processing

25

4. Safety Measures for limited operations 28

4-1 Manufacturing Flat-panel Displays (Maintenance)

28

4-2 Machining Center (Enabling Switch) 31

4-3 LCD Manufacturing (Guard Lock Control) 34

Page 8: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

8G9SX USER'S GUIDE

Ap

plicatio

n E

xamp

lesS

ection

1

1. Partial control of machine

1-1 Parts Processing MachineThe entire device stops when the Emergency Stop Switch is pressed.

Only the processing section stops when the Safety Light Curtain is interrupted.

Required Units

Unit Qty. Safety input to be applied Page

G9SX-BC 1 Emergency Stop Switch 39

G9SX-AD 1 Safety Light Curtains 40

(2) Safety Light Curtain

Processing section

Stop

Segment A

Basic UnitG9SX-BC

(1) Emergency Stop Switch

(1) Emergency Stop Switch

Segment B

(2) Safety Light Curtain

Processing section

Advanced UnitG9SX-AD

Segment ASegment A Segment B

Stop StopSegment B

Stop

Operation Example(2) Safety Light Curtain is

interrupted.(1) The Emergency Stop Switch

is pressed.

Logical AND connection

Page 9: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. Partial control of machine

G9SXUSER'S GUIDE 9

Ap

plicatio

n E

xamp

lesS

ection

1

■ Wiring ExampleSetup (For details, refer to Section 3.)

G9SX-BC: Manual reset, Cross fault detection mode: ON (Category 4 Wiring)

G9SX-AD: Auto reset, Cross fault detection mode: OFF (Category 4 Wiring (with Safety Light Curtains)),

Logical AND connections, OFF-delay time setting

Wiring Example

Note: 1. This example corresponds to category 4. (when using a Type-4 Safety Sensor).2. For further information on settings and wiring, refer to the datasheet or instruction sheet for the Safety Sensor.3. Use Safety Sensors with PNP control outputs.

S14A2 S24 S34 S44 S54 L1 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42

S14A2 S24 L1 L2 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1

KM2

KM1

S2

12

11 21

22

+24V

+24V

KM1 KM2

M1

KM2

KM1

S1

+24V +24V

+24V

M2

KM4

KM3

S34

M3

KM6

KM5

OFF

NCNC

GND

G9SX-AD322-T15

Control circuit

G9SX-BC202

Control circuit

KM4

KM3

KM6

KM5

AND

KM3 KM4 KM5 KM6

Feedback Loop

NC

PLC etc.

Motor controller

Motor controller (Operation command)

PLC etc.

Feedback Loop

F3SJ-A

GND

GND

ReceiverEmitter

Con

trol

out

put 1

Con

trol

out

put 2

S1 : Emergency Stop SwitchS2 : Reset switchKM1 to KM6 : ContactorM1 to M3 : 3-phase motor

Page 10: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

1. Partial control of machine

10G9SX USER'S GUIDE

■ Timing chart

(1) Safety Light Curtain is interrupted: Only the lower Unit stops.(2) Emergency stop button pressed: Both the upper and lower Unit stop.

G9SX-AD322-T15 (lower unit)

Reset switch S2

Emergency Stop Switch S1

KM1, KM2 NC contact

KM1, KM2 NO contact

Logical AND output L1

Logical AND input T41

Safety Light Curtain

Operation command

Rotation of motor

KM3, KM4 NC contact

KM5, KM6 NC contact

KM3, KM4 NO contact

KM5, KM6 NO contact

OFF-delay time OFF-delay time

G9SX-BC202 (upper unit) (2)

(1)

Page 11: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. Partial control of machine

G9SXUSER'S GUIDE 11

Ap

plicatio

n E

xamp

lesS

ection

1

1-2 Machining CenterWhen the Emergency Stop Switch is pressed, the entire machine will stop.

When a door is open, the corresponding part will not be activated.

Required Units

Unit Qty. Safety input to be applied Page

G9SX-BC 1 Emergency Stop Switch 39

G9SX-AD 3Guard Lock Safety Door Switch

Safety Door Switches (Set of two)40

Segment A Segment B Segment C

(4) Tool changer door

(3) Pallet changer door

(1) Emergency Stop Switch(2) Main door

Segment A Segment B

(1) The Emergency Stop Switch is pressed.

Stop StopSegment C

StopSegment A Segment B

(2) The main door is opened.

Stop StopSegment C

Stop

Segment A Segment B

(3) The pallet changer door is opened.

Stop StopSegment C

StopSegment A Segment B

(4) The tool changer door is opened.

Stop StopSegment C

Stop

Operation Example

Advanced UnitG9SX-AD

Advanced UnitG9SX-AD

Advanced UnitG9SX-AD

(3) Pallet Changer Door (4) Tool Changer Door

Safety Door Switch

Safety Door Switch

Basic UnitG9SX-BC

(2) Main Door

Logical AND connection

(1) Emergency Stop Switch

Guard LockSafety Door Switch

Page 12: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

1. Partial control of machine

12G9SX USER'S GUIDE

■ Wiring ExampleSetup (For details, refer to Section 3.)

G9SX-BC: Manual reset, Cross fault detection mode: ON (Category 4 Wiring)

G9SX-AD (main door section): Manual reset, Cross fault detection mode: ON (Category 4 Wiring),

Logical AND connections, OFF-delay time setting

G9SX-AD (pallet changer, tool changer): Auto reset, Cross fault detection mode: ON (Category 4 Wiring),

Logical AND connections, OFF-delay time setting

Wiring Example

PLC etc.

PLC etc.

PLC etc.

S14A2 S24 S34 S44 S54 L1 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42

S14A2 S24 L1 L2 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1

KM2

KM1

S2

S6

12

11 21

22

+24V

KM1 KM2

M1

KM2

KM1

S1

+24V

KM3 KM4

S344

M2

KM4

KM3

Motor controllerS344

M4

KM8

KM7

S344

M3

KM6

KM5

OFF

AND

S8

Open

S7

NC

NC

Feedback Loop

Lock release signal

GND

GND

G9SX-AD322-T15 (Main door)

Control circuit

G9SX-BC202

Control circuit

Feedback Loop

S14A2 S24 S34 S44 S54 L1 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42

+24V+24V

+24V+24V

OFF

ANDNC

GND

G9SX-AD322-T15 (Tool changer door)

Control circuit

KM8

KM7

PLC etc.

Feedback Loop

S14A2 S24 S34 S44 S54 L1 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42

+24V+24V

KM5 KM6

OFF

ANDNC

GND

G9SX-AD322-T15 (Pallet changer door)

Control circuit

KM6

KM5

S4

Feedback Loop

KM3

KM4

41

42

12

11

S5

KM4

KM3

S3

Open

KM7 KM8

Motor controller(Operation command)

Motor controller(Operation command)

Motor controller(Operation command)

Motor controller

Motor controller

Stop signal

Guard

S1 : Emergency Stop SwitchS2, S6 : Reset switchS3 : Guard Lock Safety Door SwitchS4 : Safety Limit SwitchS5 : Lock release switchS7, S8 : Safety Door SwitchKM1 to KM8 : ContactorM1 to M4 : 3-phase motor

Note: This example corresponds to category 4.

Page 13: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. Partial control of machine

G9SXUSER'S GUIDE 13

Ap

plicatio

n E

xamp

lesS

ection

1

■ Timing chart

(1) Before operation is started.(2) Main door is unlocked and opened, and then work is performed.(3) Restart operation after the main door is closed.(4) The pallet changer door opens and the pallet changer section stops.(5) The pallet changer door is closed and the pallet changer is reset.(6) The tool changer door opens and the tool changer section stops.(7) The tool changer door is closed and the tool changer section is reset.(8) If the Emergency Stop Switch is pressed, the upper unit and lower units will stop.

Emergency Stop Switch S1

Reset switch S2

Logical AND output L1

KM1, KM2 NC contact

KM1, KM2 NO contact

Logical AND input T41

Logical AND input T41

Logical AND input T41

KM3, KM4 NC contact

KM3, KM4 NO contact

Safety Limit Switch S4

Safety Door Switch S7

Safety Door Switch S8

Reset switch S6

Operation command

Rotation of motor

Operation command

Rotation of motor

Operation command

Rotation of motor

OFF-delay timeOFF-delay time

OFF-delay time OFF-delay time

OFF-delay time OFF-delay time

Door can be opened.Stop signal

Lock release signal

Lock release switch S5

Guard Lock Safety Door Switch S3

(1) (2) (3)

(8)

(4) (5)

(6) (7)

G9SX-BC202 (upper unit)

KM5, KM6, NC contact

KM5, KM6, NO contact

KM7, KM8, NC contact

KM7, KM8, NO contact

G9SX-AD322-T15 (lower unit : Main door)

G9SX-AD322-T15 (lower unit : Pallet changer door)

G9SX-AD322-T15 (lower unit : Tool changer door)

Page 14: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

1. Partial control of machine

14G9SX USER'S GUIDE

■ Timing chart

(1) Before operation is started.(2) The processing section cover is opened, and the processing section and the conveyor section stops.(3) The processing section cover is closed and the processing section and conveyor section restart.(4) The conveyor section cover is opened and the conveyor section stops.(5) The transport section cover is closed and the conveyor section restarts.(6) If the Emergency Stop Switch is pressed, unit A, unit B, and unit C will stop.

G9SX-BC202 (Unit A)

G9SX-AD322-T15 (Unit B:Processing section cover)

G9SX-AD322-T15 (Unit C:Conveyor section cover)

Emergency Stop Switch S1

Reset switch S2

Logical AND output L1

KM1, KM2 NC contact

KM1, KM2 NO contact

KM3, KM4 NC contact

KM3, KM4 NO contact

Operation command

Rotation of motor

Logical AND input T41

Operation command

Rotation of motor

KM5, KM6, NC contact

KM5, KM6, NO contact

Logical AND input T41

Safety Door Switch S4

Safety Door Switch S3

OFF-delay time OFF-delay time OFF-delay time

OFF-delay timeOFF-delay time

(4)

(3)

(6)

(2)(1)

(5)

Logical AND output L1

Page 15: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. Partial control of machine

G9SXUSER'S GUIDE 15

Ap

plicatio

n E

xamp

lesS

ection

1

1-3 Semiconductor Manufacturing EquipmentWhen the Emergency Stop Switch is pressed, all of the equipment stops.

When the processing section cover is opened, the processing section and conveyor section stop.

When the conveyor section cover is opened, only the conveyor section stops.

Required Units

Unit Qty. Safety input to be applied Page

G9SX-BC 1 Emergency Stop Switch 39

G9SX-AD 2 Safety Door Switches (Set of two) 40

Logical ANDconnection

Safety Door Switch

Safety Door Switch

Advanced UnitG9SX-AD

Advanced UnitG9SX-AD

Segment CSegment B

Basic UnitG9SX-BC

Logical AND connection

(1) Emergency Stop Switch

Segment A

(3) The conveyor section cover is opened.

(1) The Emergency Stop Switch is pressed.

(2) The processing section cover is opened.

Operation Example

(2) Processing section cover (3) Conveyor section cover

(1) Emergency Stop Switch

(2) Processing section cover

(3) Conveyor section cover

Segment A Segment B Segment C

StopSegment A Segment B

Stop StopSegment C

StopSegment A Segment B

StopSegment C

Stop

Page 16: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

1. Partial control of machine

16G9SX USER'S GUIDE

■ Wiring ExampleSetup (For details, refer to Section 3.)

G9SX-BC: Manual reset, Cross fault detection mode: ON (Category 4 Wiring)

G9SX-AD: Auto reset, Cross fault detection mode: ON (Category 4 Wiring), Logical AND connections,

OFF-delay time setting

Wiring Example

S14A2 S24 L1 L2 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1

KM2

KM1

S2

12

11 21

22

+24V

M1

KM2

KM1

S1

+24VNC

GND

G9SX-BC202 (Unit A)

Control circuit

S344

M3

KM6

KM5

Open

S4

Feedback Loop

S14A2 S24 S34 S44 S54 L1 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42

+24V+24V

KM5 KM6

OFF

ANDNC

GND

G9SX-AD322-T15 (Unit C)

Control circuit

KM6

KM5

Motor controller

Motor controller

S344

M2

KM4

KM3

Open

S3

PLC etc.

Feedback Loop

S14A2 S24 S34 S44 S54 L1 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42

+24V+24V

KM3 KM4

OFF

ANDNC

GND

G9SX-AD322-T15 (Unit B)

Control circuit

KM4

KM3

Feedback Loop

KM1 KM2

Motor controller(Operation command)

Motor controller(Operation command)

PLC etc.

PLC etc.

S1 : Emergency Stop SwitchS2 : Reset switchS3, S4 : Safety Door SwitchKM1 to KM6 : ContactorM1 to M3 : 3-phase motor

Note: This example corresponds to category 4.

Page 17: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. Partial control of machine

G9SXUSER'S GUIDE 17

Ap

plicatio

n E

xamp

lesS

ection

1

1-4 Machine ToolWhen the Emergency Stop Switch is pressed, the entire machine will stop.

If the left door is opened, the left drive section and transport section will stop.

If the right door is opened, the right drive section and transport section will stop.

Required Units

Unit Qty. Safety input to be applied Page

G9SX-BC 1 Emergency Stop Switch 39

G9SX-AD 2 Safety Door Switches (Set of two) 40

G9SX-ADA 1 --- 41

Safety Door Switch

Advanced UnitG9SX-AD

Advanced UnitG9SX-AD

(2) Left door (3) Right door

Safety Door Switch

Segment A Segment B

Segment C

Advanced UnitG9SX-ADA

Logical ANDconnection

Logical AND connection

Logical AND connection

Transport section

Basic UnitG9SX-BC

(1) Emergency Stop Switch

(2) Left door (3) Right door

(1) The Emergency Stop Switch is pressed.

(2) The left door is opened. (3) The right door is opened.

Operation Example

(1) Emergency Stop Switch

Segment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment B

Stop

Segment A

StopSegment C

Stop

Segment A

StopSegment B

Stop

Segment A

StopSegment C

StopSegment A

StopSegment C

Stop

Segment A

StopSegment B

Stop

Page 18: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

1. Partial control of machine

18G9SX USER'S GUIDE

■ Wiring ExampleSetup (For details, refer to Section 3.)

G9SX-BC: Manual reset, Cross fault detection mode: ON (Category 4 Wiring)

G9SX-AD: Auto reset, Cross fault detection mode: ON (Category 4 Wiring), Logical AND connections,

No OFF-delay time setting

G9SX-ADA: Auto reset, Cross fault detection mode: ON (Category 4 Wiring), Logical AND connections,

OFF-delay time setting

Wiring Example

PLC etc.

S14A2 S24 L1 L2 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1

KM2

KM1

S2

12

11 21

22

+24V

KM1 KM2

M1

KM2

KM1

S1

+24VNC

GND

G9SX-BC202

Feedback Loop

Open

S3

PLC etc.

Feedback Loop

S14A2 S24 S34 S44 S54 L1 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42

+24V+24V

KM3 KM4

OFF

AND

Left drive section

Transport section

Right drive section

NC

GND

G9SX-AD322-T15 (Left door)

Control circuit

KM4

KM3

M3

KM6

KM5

M2

KM4

KM3

Open

S4

PLC etc.

Feedback Loop

S14A2 S24 S34 S44 S54 L1 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42

+24V+24V

KM5 KM6

OFF

ANDNC

GND

G9SX-AD322-T15 (Right door)

Control circuit

KM6

KM5

PLC etc.

Motor controllerS344

M4

KM8

KM7

G9SX-ADA222-T150

S14A2 S24 S44 S54 L1 X1S34 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42

+24+24V V

OFF

ANDNC

Feedback Loop

GND

Control circuit

KM2

KM1

T51 T52

KM7 KM8

Control circuit

Motor controller(Operation command)

S1 : Emergency Stop SwitchS2 : Reset switchS3, S4, S5 : Safety Door SwitchKM1 to KM8 : ContactorM1 to M4 : 3-phase motor

Note: This example corresponds to category 4.

Page 19: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. Partial control of machine

G9SXUSER'S GUIDE 19

Ap

plicatio

n E

xamp

lesS

ection

1

■ Timing chart

(1) Before operation is started.(2) The left door is opened and the left drive section and transport section stop.(3) The left door is closed and the left drive section and transport section restart.(4) The right door is opened and the right drive section and transport section stop.(5) The right door is closed and the right drive section and transport section restart.(6) If the Emergency Stop Switch is pressed, the Upper Unit, Middle Unit, and Lower Unit will stop.

G9SX-AD322-T15 (middle unit: Left door)

G9SX-BC202 (upper unit)

G9SX-AD322-T15 (middle unit: Right door)

Emergency Stop Switch S1

Reset switch S2

Logical AND output L1

KM1, KM2 NC contact

KM1, KM2 NO contact

G9SX-ADA222-T150 (lower unit)

Logical AND output L1

Logical AND input T41

Logical AND input T41

Logical AND input T41

Logical AND input T51

Operation command

Rotation of motor

KM5, KM6, NC contact

KM5, KM6, NO contact

KM7, KM8, NC contact

KM7, KM8, NO contact

Safety Door Switch S4

KM3, KM4 NC contact

KM3, KM4 NO contact

Safety Door Switch S3

Logical AND output L1

OFF-delay time OFF-delay time OFF-delay time

(4) (5)

(2)(1) (3)

(6)

Page 20: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

20G9SX USER'S GUIDE

Ap

plicatio

n E

xamp

lesS

ection

1

2. Using Non-contact Door Switch

2-1 Pick and Place MachineIf the Emergency Stop Switch is pressed, the entire machine will stop.

If the cover is opened, the entire machine will stop.

Required Units

Unit Qty. Safety input to be applied Page

G9SX-NSA 1Emergency Stop Switch +

Non-contact Door Switch D40A43

G9SX-NSA

(1) Emergency Stop Switch

Motor

(1) Emergency Stop Switch

(1) The Emergency Stop Switch is pressed.

Operation Example

CoverCover(2) Non-contact Door Switch

(2) Non-contact Door Switch D40A

Segment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopMotor

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopSegment A

StopMotor

Stop

(2) Cover is opened.

Page 21: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Using Non-contact Door Switch

G9SXUSER'S GUIDE 21

Ap

plicatio

n E

xamp

lesS

ection

1

■ Wiring ExampleSetup (For details, refer to Section 3.)

G9SX-NSA: Manual reset, Cross fault detection mode: OFF (Category 2 Wiring), Logical AND connections: OFF,

OFF-delay time setting

Wiring Example

■ Timing chart

S14

M1

KM2

KM1

OFF

AND

G9SX-NSA222-T03

Control circuit

KM2

KM1

+24V

GND

S3

S2

+24V

+24V

12

11

S1

Motor controller(Operation command)

X2X1L1S54S44A2

A1

S24S14

T11 T12 T21 T22 T31 T32 T33 T41 T42Y1 D1 D2 D3 D4

KM2KM1

Feedback Loop

Non

-con

tact

D

oor

Sw

itch

Act

uato

r

Bla

ck

Bro

wn

Whi

te

blue

PLC etc.

NCNC

Motor controller

NC NC

S1 : Emergency Stop SwitchS2 : Non-contact Door SwitchS3 : Reset switchKM1, KM2 : ContactorM1 : 3-phase motor

Note: This example corresponds to category 2.

Emergency Stop Switch S1

Non-contact Door Switch S2

OFF-delay time

Emergency Stop Switch operation

OFF-delay time

KM1, KM2 NC contact

KM1, KM2 NO contact

Operation command

Rotation of motor

Reset switch S3

Page 22: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

2. Using Non-contact Door Switch

22G9SX USER'S GUIDE

2-2 Small Assembly SystemWhen the Emergency Stop Switch is pressed, both robots will stop.

When robot door A is opened, robot A will stop.

When robot door B is opened, robot B will stop.

Required Units

Unit Qty. Safety input to be applied Page

G9SX-BC 1 Emergency Stop Switch 39

G9SX-NS 2 Non-contact Door Switches D40A (Set of two) 42

Robot A Robot B

Logical AND connections

(1) Emergency Stop Switch

D40A

G9SX-NS G9SX-NS

(2) Robot door A (3) Robot door B

(2) Robot door A

(3) Robot door B

G9SX-BC

D40A

(2) Robot door A opened.

(3) Robot door B opened.

(1) Emergency Stop Switch

StopStopStopStop StopRobot A

StopStopStopStopRobot A

StopStopStopStopRobot B Robot B

StopStopStopStopStopRobot BRobot A

(1) The Emergency Stop Switch is pressed.

Operation Example

Page 23: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Using Non-contact Door Switch

G9SXUSER'S GUIDE 23

Ap

plicatio

n E

xamp

lesS

ection

1

■ Wiring ExampleSetup (For details, refer to Section 3.)

G9SX-BC: Manual reset, Cross fault detection mode: ON (Category 4 Wiring)

G9SX-NS: Auto reset, Logical AND connections (Category 3 Wiring)

Wiring Example

Note: This example corresponds to category 3.

M3

KM6

KM5

KM6

KM5

+24VNC

+24V

OFF

AND

G9SX-NS202 (Robot door B)

Control circuit

S4

KM6KM5

S14 S24A2

A1 D1 D3 D4 Y1T31 T32 T33 T41 T42D2

L1 X1 X2

NC

Y1

M2

KM4

KM3

KM4

KM3

+24V+24V

OFF

AND

G9SX-NS202 (Robot door A)

S3

KM4KM3

S14 S24A2

A1 D1 D3 D4 T31 T32 T33 T41 T42D2

L1 X1 X2

KM2

KM1

S2

12

11 21

22

+24V

M1

KM2

KM1

S1

+24VNC

G9SX-BC202

Control circuit

KM2KM1

S14 S24A2

A1 T11T11 T12 T21 T22 T31 T32 T33 Y1

L1 L2 X1 X2

Feedback Loop

GND

GND GND

Control circuit

PLC etc.

Act

uato

r

Non

-con

tact

D

oor

Sw

itch

Act

uato

r

Non

-con

tact

D

oor

Sw

itchFeedback Loop Feedback Loop

PLC etc. PLC etc.

S1 : Emergency Stop SwitchS2 : Reset switchS3, S4 : Non-contact Door SwitchKM1 to KM6 : ContactorM1 to M3 : 3-phase motor

Page 24: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

2. Using Non-contact Door Switch

24G9SX USER'S GUIDE

■ Timing chart

(1) Before operation is started.(2) Robot door A is opened and robot A stops.(3) Robot door A is closed and robot A restarts.(4) Robot door B is opened and robot B stops.(5) Robot door B is closed and robot B restarts.(6) If the Emergency Stop Switch is pressed, the upper unit, lower unit A, and lower unit B will all stop.

G9SX-NS202 (lower unit : Robot A)

G9SX-NS202 (lower unit : Robot B)

Emergency Stop Switch S1

Reset switch S2

Logical AND output L1

KM1, KM2 NC contact

KM1, KM2 NO contact

G9SX-BC202 (upper unit)

Logical AND input T41

Logical AND input T41

KM3, KM4 NC contact

KM3, KM4 NO contact

KM5, KM6 NC contact

KM5, KM6 NO contact

Non-contact Door Switch S3

Non-contact Door Switch S4

Rotation of motor M3

Rotation of motor M2

Rotation of motor M1

(6)

(1) (2) (3)

(4) (5)

Page 25: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 25

Ap

plicatio

n E

xamp

lesS

ection

1

3. Coordinated operation of worker and machine

3-1 Manufacturing Automotive Parts Using Semi-automatic ProcessingTwo pairs of Light Curtains are automatically enabled and disabled according to the operations of the operator and robot.

Required Units

Unit Qty. Safety input to be applied Page

G9SX-BC 1 Emergency Stop Switch 39

G9SX-GS 1 Light Curtain + Light Curtain 44

Basic Unit G9SX-BC

Logical AND connection

(1) Emergency Stop Switch A22E

(1) Emergency Stop Switch

(2) Safety Light Curtain A

(3) Safety Light Curtain B

Safety Light CurtainF3SJ

Safety Light CurtainF3SJ

(2) Safety Light Curtain A (3) Safety Light Curtain B

Safety Guard Switching UnitG9SX-GS

Robot

Contactor

Auto switching

Emergency Stop Switch

Safety Light Curtain A

Safety Light Curtain B

When pressed, processing will stop.

When both are interrupted simultaneously, processing will stop.

Page 26: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

3. Coordinated operation of worker and machine

26G9SX USER'S GUIDE

■ Wiring ExampleSetup (For details, refer to Section 3.)

G9SX-BC: Manual reset, Cross fault detection mode: ON (Category 4 Wiring)

G9SX-GS: Auto reset, Cross fault detection mode: OFF (Category 4 Wiring (with Safety Light Curtains)),

Logical AND connections,

OFF-delay time setting

Switching mode: Auto

Diagnostic check of Indicator : Enabled (UB only)

Wiring Example

Note: This example corresponds to category 4.

S2

12

11 21

22

+24V

S1

+24V+24V+24V +24V

+24V

G9SX-BC202

Control circuit

G9SX-GS226-T15

GND GND

+24V

GND

GND

M2

KM4

KM3

Auto

Manual

OFF

ANDT42T41T33T32T31Y4Y2T72T71T62T61M2M1Y3Y1T22T21T12T11A1

KM3

KM4

Control circuit

UBUAX4X3X2X1L1

KM4KM3

S54S44S24S14A2

M1

KM1

KM2

KM2

KM1

Y1T33T32T31T22A1 T11 T12 T21

X2X1L2L1S14 S24

KM1 KM2

A2

F3SJ-A F3SJ-A

NC

Emergency Stop Switch

PLC etc.

Feedback loop

ReceiverEmitter ReceiverEmitter

Safety Sensor A Safety Sensor B

NCNCNC NC NC NC

Con

trol

out

put 2

Con

trol

out

put 1

Con

trol

out

put 1

Con

trol

out

put 2

PLC etc.

Indicator(Diagnostic

check disabled)

Indicator(Diagnostic

check enabled)

NC

Feedback Loop

S1 : Emergency Stop SwitchS2 : Reset switchKM1 to KM4 : ContactorM1 to M2 : 3-phase motor

Page 27: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

3. Coordinated operation of worker and machine

G9SXUSER'S GUIDE 27

Ap

plicatio

n E

xamp

lesS

ection

1

■ Timing chart

(1) Before operation is started.(2) Operator inserts workpiece(3) Robot processes workpiece(4) Both operator and robot enter the coordinated area: Only the G9SX-GS stops.(5) The G9SX-GS restarts.(6) Emergency stop button pressed: All units stop.

Emergency Stop Switch S1

Reset switch S2

Logical AND output L1

KM1, KM2 NC contact

KM1, KM2 NO contact

External indicator output UA

Logical AND input T41

Safety Sensor B control output (monitoring the operator)

Safety Sensor A control output (monitoring the robot)

Input B monitor output X4

Input A monitor output X3

External indicator output UB

Controls not related to safety

KM3, KM4 NC contact

KM3, KM4 NO contact

Robot movement enabled

Robot movement disabled

Robot movement enabled in specific area only

G9SX-BC202

G9SX-GS226-T15

(3)(1)

(4) (5)(2)

(6)

Page 28: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

28G9SX USER'S GUIDE

Ap

plicatio

n E

xamp

lesS

ection

1

4. Safety Measures for limited operations

4-1 Manufacturing Flat-panel Displays (Maintenance)Switching between Normal Operating Mode and Maintenance Mode is performed manually.

In Normal Operating Mode, the Safety Door Switch is enabled, and in Maintenance Mode the Safety Limit Switch is enabled.

Required Units

Unit Qty. Safety input to be applied Page

G9SX-BC 1 Emergency Stop Switch 39

G9SX-GS 1 Door Switch + Limit Switch 44

(1) Emergency Stop Switch

(3) Conveyor cart (Safety Limit Switch)

(2) Cover (Safety Door Switch)

(4) Mode selector

(3) Conveyor cart (4) Mode selector(2) Cover

Safety Limit SwitchD4F

Key-type Selector Switch A22K

Safety Door SwitchD4NS

Safety Guard Switching UnitG9SX-GS

Contactor

Basic UnitG9SX-BC

Logical AND connection

(1) Emergency Stop Switch A22E

Conveyor cart

Emergency Stop Switch

Normal operating mode

Maintenance mode

Cover

Conveyor cart

When pressed, processing will stop.

When the cover is opened, processing will stop.

Emergency Stop Switch

Cover

Conveyor cart

When pressed, processing will stop.

Processing will continue regardless of whether the cover is opened or closed.

Processing will continue regardless of the conveyor cart position.

When the conveyor cart moves away from its safe position, processing will stop.

Manual switching

Manual switching

Page 29: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

4. Safety Measures for limited operations

G9SXUSER'S GUIDE 29

Ap

plicatio

n E

xamp

lesS

ection

1

■ Wiring ExampleSetup (For details, refer to Section 3.)

G9SX-BC: Manual reset, Cross fault detection mode: ON (Category 4 Wiring)

G9SX-GS: Manual reset, Cross fault detection mode: ON (Category 4 Wiring), Logical AND connections,

OFF-delay time setting

Switching mode: Manual

Diagnostic check of Indicator: Enabled (UA only)

Wiring Example

Note: This example corresponds to category 4.

S14A2 S24 L1 L2 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1

KM2

KM1

S2

12

11 21

22

+24V

KM1 KM2

M1

KM2

KM1

S1

KM4

KM3

+24V

+24V

+24V

M2

KM4

KM3

KM4KM3

G9SX-BC202

Control circuit

S14A2 S24 S44 S54 L1 X3X2X1 X4 UA

T11A1 T12 T21 Y1 Y3T22 T61 T62M1 M2 T71 Y2 Y4T72 T31 T32 T33 T41 T42OFF

AND

Auto

Manual

G9SX-GS226-T15

Control circuit

23

24

11

12

11

12

S3

S421

22

S6

+24V

GND

UB

+24V

S5

NC

Feedback loopEmergency Stop Switch

PLC etc.

NCNC

Mode selector

Cover

NC

Feedback loop

PLC etc.

Indicator (Diagnostic

check enabled)

Indicator (Diagnostic

check disabled)

Conveyor cart

S1 : Emergency Stop SwitchS2, S7 : Reset switchS3, S4 : Safety Limit SwitchS5 : Safety Door SwitchS6 : Selector switchKM1 to KM4 : ContactorM1 to M2 : 3-phase motor

Page 30: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

4. Safety Measures for limited operations

30G9SX USER'S GUIDE

■ Timing chart

(1) Start the G9SX-GS in normal operating mode.(2) Switch to maintenance mode.(3) The operator opens the door and performs maintenance.(4) When Safety Limit Switch S3 and Limit Switch S4 are turned OFF in maintenance mode, the G9SX-GS stops.(5) After the door is closed and the operating mode is switched to normal operating mode, restart the G9SX-GS.(6) When the door is opened during normal operating mode, the G9SX-GS stops.(7) Close the door and restart the G9SX-GS.(8) When the operating mode is switched to maintenance mode while Safety Limit Switch S3 and Limit Switch S4 are turned OFF, the G9SX-GS

stops.(9) Switch to normal operating mode, and when the door is closed, restart the G9SX-GS.(10) Emergency stop button pressed: All units stop.

Emergency Stop Switch S1

Reset switch S2

Logical AND output L1

KM1, KM2 NC contact

KM1, KM2 NO contact

Input B monitor output X4

Input A monitor output X3

External indicator output UB

External indicator output UA

Logical AND input T41

Mode selector input M2

Safety Limit Switch S3

Mode selector input M1

Reset switch S6

Safety Door Switch

KM3, KM4 NC contact

KM3, KM4 NO contact

Limit Switch S4

Conveyor section movement enabled (with machine in normal operating mode)

Conveyor section movement enabled in specific area only (with machine in maintenance mode)

Conveyor section movement disabled

G9SX-BC202

G9SX-GS226-T15

Controls not related to safety

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Page 31: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

4. Safety Measures for limited operations

G9SXUSER'S GUIDE 31

Ap

plicatio

n E

xamp

lesS

ection

1

4-2 Machining Center (Enabling Switch)Switching between Normal Operating Mode and Maintenance Mode is performed manually.

In Normal Operating Mode, the Safety Door Switch is enabled, and in Maintenance Mode, the Safety Limit Switch is enabled.

Required Units

Unit Qty. Safety input to be applied Page

G9SX-BC 1 Emergency Stop Switch 39

G9SX-GS 1 Door Switch + Enabling Switch 44

EnablingSwitch

Door

Enabling Device

Enabling Device

Guard LockSafety DoorSwitches

(3) Enabling Switch

Emergency Stop Switch

Normal operating mode

Maintenance mode

When pressed, processing will stop.

When the door is opened, processing will stop.

The enabling switch is disabled.

When pressed, processing will stop.

Door Switch is disabled.

Processing will be possible only when the operator is gripping the enabling switch.

Emergency Stop Switch

Manual switching

Manual switching

(4) Mode selector(3) Motor(2) Door

Key-type Selector Switch A22K

Safety Guard Switching UnitG9SX-GS

Contactor

Basic UnitG9SX-BC

Logical AND connection

(1) Emergency Stop Switch A22E

Conveyor cart

(1) Emergency Stop Switch

(2) Safety Door Switch

Door

Page 32: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

4. Safety Measures for limited operations

32G9SX USER'S GUIDE

■ Wiring ExampleSetup (For details, refer to Section 3.)

G9SX-BC: Manual reset, Cross fault detection mode: ON (Category 4 Wiring)

G9SX-GS: Manual reset, Cross fault detection mode: ON (Category 4 Wiring), Logical AND connections,

OFF-delay time setting

Switching mode: ManualDiagnostic check of Indicator: Enabled

Wiring Example

S14A2 S24 L1 L2 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1

KM2

KM1

S2

12

11 21

22

+24V

KM1 KM2

M1

KM2

KM1

PLC etc.

S1

KM4

KM3

+24V

+24V

M2

KM4

KM3

KM4KM3 PLC etc.

NC NC

NC

NCNC

Feedback Loop

Feedback Loop

G9SX-BC202

Control circuit

S14A2 S24 S44 S54 L1 X3X2X1 X4

T11A1 T12 T21 Y1 Y3T22 T61 T62M1 M2 T71 Y2 Y4T72 T31 T32 T33 T41 T42OFF

AND

Auto

Manual

G9SX-GS226-T15

Control circuit

S3 S7

+24V

GND

GND

EnablingSwitch

S4

OPEN

S5

KM3

KM4

31

32

11

12

Stop sigmal

Door

S6

UA UB

+24V

Indicator (Diagnostic

check enabled)

Indicator (Diagnostic

check enabled)

Mode selector

Lock release signal

2 4

1 3

S1 : Emergency Stop SwitchS2, S7 : Reset switchS3 : Enabling SwitchS4 : Guard Lock Door SwitchS5 : Lock release switchS6 : Safety Limit SwitchKM1 to KM4 : ContactorM1 to M2 : 3-phase motor

Note: This example corresponds to category 4.

Page 33: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

4. Safety Measures for limited operations

G9SXUSER'S GUIDE 33

Ap

plicatio

n E

xamp

lesS

ection

1

■ Timing chart

(1) In Normal operating mode, the lower unit starts. (2) Maintenance mode is selected.(3) The operator opens the door and performs maintenance operation.(4) The Enabling Switch is gripped to the middle position.(5) In maintenance mode, the lower unit starts.(6) When the Enabling Switch is released or gripped, the lower unit stops.(7) After closing the door and then switching to Normal operating mode, the lower unit will restart.(8) If the door is opened while in Normal operating mode, the lower unit will stop.(9) The door is closed, and the lower unit restarts.(10) If the Emergency Stop Switch is pressed, the upper unit and lower unit will stop.

Guard Lock Door Switch S4

Enabling Switch S3

Emergency Stop Switch S1

Reset switch S2

Logical AND output L1

KM1, KM2 NC contact

KM1, KM2 NO contact

G9SX-BC202 (upper unit)

G9SX-GS226-T15 (lower unit)

Logical AND input T41

Reset switch S7

OFF-delay time OFF-delay time OFF-delay time OFF-delay time

(4) (6)

(7) (9)

(10)

(5)

(2)

(3) (8)

(1)

KM3, KM4 NC contact

KM5, KM6 NC contact

KM3, KM4 NO contact

KM5, KM6 NO contact

Mode selector input M2

Mode selector input M1

Page 34: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

4. Safety Measures for limited operations

34G9SX USER'S GUIDE

4-3 LCD Manufacturing (Guard Lock Control)When the Safety Limit Switch has confirmed that the hazard source is in a safe position, the Guard Lock Safety Door Switch will be unlocked.

Required Units

Unit Qty. Safety input to be applied Page

G9SX-BC 1 Emergency Stop Switch 39

G9SX-GS 1 Guard Lock Door Switch + Limit Switch 44

Guard Lock Door Switch

Guard LockSafety DoorSwitches

(2) Guard Lock Door Switch

(1) Emergency Stop Switch

(3) Safety Limit Switch

Safety Guard Switching UnitG9SX-GS

Motor

Contactor

Basic UnitG9SX-BC

Logical AND connection

(1) Emergency Stop Switch A22E

(3) Conveyor cart(2) Door

Emergency Stop Switch

Auto switching

When pressed, processing will stop.

When turned OFF at the same time, the machine will stop.

Safety Limit SwitchD4F

Limit Switch

Page 35: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

4. Safety Measures for limited operations

G9SXUSER'S GUIDE 35

Ap

plicatio

n E

xamp

lesS

ection

1

■ Wiring ExampleSetup (For details, refer to Section 3.)

G9SX-BC: Manual reset, Cross fault detection mode: ON (Category 4 Wiring)

G9SX-GS: Manual reset, Cross fault detection mode: ON (Category 4 Wiring), Logical AND connections,

No OFF-delay time setting

Switching mode: Auto

Diagnostic check of Indicator: Enabled (UA only)

Wiring Example

S14A2 S24 L1 L2 X1 X2

T11A1 T12 T21 T22 T31 T32 T33 Y1

KM2

KM1

S2

12

11 21

22

+24V

KM1 KM2

M1

KM2

KM1

PLC etc.

S1

KM4

KM3

+24V

+24V

M2

KM4

KM3

KM4KM3

NC

NC

NCNC

Feedback Loop

Feedback Loop

G9SX-BC202

Control circuit

S14A2 S24 S44 S54 L1 X3X2X1 X4 UA

T11A1 T12 T21 Y1 Y3T22 T61 T62M1 M2 T71 Y2 Y4T72 T31 T32 T33 T41 T42OFF

AND

Auto

Manual

G9SX-GS226-T15

Control circuit

S5

S6

Limit SwitchLimit Switch

Limit Switch

Guard LockDoor Switch(Mechanical lock) S4

Conveyor cart

S7

+24V

GND

GND

UB

+24V

GND

OPEN

42

41

12

11

22

E1 E2

21

Door

Indicator (Diagnostic

check enabled)

Lock releaseswitch

S1 : Emergency Stop SwitchS2, S7 : Reset switchS3 : Lock release switchS4 : Guard Lock Door SwitchS5, S6 : Limit SwitchKM1 to KM4 : ContactorM1 to M2 : 3-phase motor

Note: This example corresponds to category 4.

Page 36: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

plicatio

n E

xamp

lesS

ection

1

4. Safety Measures for limited operations

36G9SX USER'S GUIDE

■ Timing chart

(1) When the door is closed, operation is initiated with the reset switch.(2) The Limit Switch detects the conveyor cart and the lock release signal turns ON. (3) The door can be opened while the lock release switch pressed.(4) The door is closed again. (5) The conveyor cart moves.(6) The Limit Switch detects the conveyor cart, and the lock release signal turns ON.(7) The door can be opened while the lock release switch is pressed.(8) The conveyor cart moves while the door is open, and the lower unit stops.(9) The door is closed again. The lower unit remains stopped.(10) The reset switch is used to restart operation.(11) If the Emergency Stop Switch is pressed, the upper unit and lower unit will stop.

Emergency Stop Switch S1

Reset switch S2

Logical AND output L1

KM1, KM2 NC contact

KM1, KM2 NO contact

G9SX-BC202 (upper unit)

G9SX-GS226-T15 (lower unit)

Logical AND input T41

Reset switch S7

KM3, KM4 NC contact

KM3, KM4 NO contact

(6)(5)(1)

(3) (4) (9)

(10)

(11)

(2) (7) (8)Safety Limit Switch S5

Safety Limit Switch S6

Lock release signal

Lock release switch S1

Door can be opened.Door can be opened.

(External indicator output UA)

Guard Lock Door Switch S4

Page 37: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 37

Fu

nctio

ns o

f G9S

XS

ection

2

Section 2Functions of G9SX

1. Function list of G9SX-series 38

2. Functions of each Unit 39

2-1 Basic Unit 39

2-2 Advanced Unit 40

2-3 Non-Contact Door Switch Controller 42

2-4 Safety Guard Switching Unit 44

2-5 Expansion Unit 48

Page 38: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

38G9SX USER'S GUIDE

Fu

nctio

ns o

f G9S

XS

ection

2

1. Function list of G9SX-series

Function Model G9SX-BC G9SX-AD G9SX-ADA G9SX-NS G9SX-NSA G9SX-GS

Logical AND connections

Inputs --- ●●

(2 inputs)● ● ●

Outputs ● ● ● ● ● ●

Safety inputs

Emergency stop ● ● ● --- ● ---

Door switch ● ● ● --- ● ●

Non-contact door switch(D40A)

--- --- --- ● ● ---

Light curtain ● ● ● --- --- ●

Number of safety inputs 1 1 1 1 2 2

Safety outputs

Instantaneous outputs

2 3 2 2 2 2

OFF-delayed outputs

--- 2 2 --- 2 2

OFF-delay time ---0 to 15 s,0 to 150 s

0 to 15 s,0 to 150 s

--- 0 to 3 s 0 to 15 s

Expansion Unit connection

--- ● ● --- ● ●

Guard switching --- --- --- --- --- ●

Page 39: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 39

Fu

nctio

ns o

f G9S

XS

ection

2

2. Functions of each Unit

2-1 Basic UnitIt is possible to connect to other Units by using the logical AND connection output.

■ G9SX-BC@Safety Inputs

Safety Outputs (Semiconductor Outputs)

Logical AND Connections

Required Settings and Wiring

LED Indicators

Safety inputs 1 input (2-channel input)

Safety input devicesEmergency stop switch, door switch,light curtain

Instantaneous outputs 2 outputs

OFF-delayed outputs None

Number of inputs None

Number of outputs 2 outputs

Item G9SX-BC Page

Logical AND connection input enable/disable

--- ---

Cross fault detection mode ❍ 63

Reset mode ❍ 62

OFF-delay time --- ---

Switching mode --- ---

External indicator fault diagnosis mode

--- ---

Safety Input

Safety Instantaneous

Output

Logical AND Connection

Output

No.

T1 T2

FB

ERREI

PWR

L2L1S24S14A2X2T22T21

A1X1T12T11Y1T32 T33T31

G9SX-BC20224VDC

Marking Color Name

PWR Green Power supply indicator

T1 Orange Safety input #1 indicator

T2 Orange Safety input #2 indicator

FB Orange Feedback/reset input indicator

EI Orange Safety output indicator

ERR Red Error indicatorNo.

T1 T2

FB

ERREI

PWR

L2L1S24S14A2X2T22T21

A1X1T12T11Y1T32 T33T31

G9SX-BC20224VDC

Page 40: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Fu

nctio

ns o

f G9S

XS

ection

2

2. Functions of each Unit

40G9SX USER'S GUIDE

2-2 Advanced UnitThis Unit has safety OFF-delayed outputs and can be connected to other Units using the logical AND connection

input and output.

■ G9SX-AD@Safety Inputs

Safety Outputs (Semiconductor Outputs)

Note: The OFF-delayed outputs can be used as instantaneous outputs bysetting the OFF-delay time to 0 s.

Logical AND Connections

OFF-delay Time Setting

Required Settings and Wiring

LED Indicators

Safety inputs 1 input (2-channel input)

Safety input devicesEmergency stop switch, door switch, light curtain

Instantaneous outputs 3 outputs

OFF-delayed outputs 2 outputs

Number of inputs 1 input

Number of outputs 1 output

G9SX-AD322-T15-@ 0 to 15 s

G9SX-AD322-T150-@ 0 to 150 s

Item G9SX-AD Page

Logical AND connection input enable/disable

❍ 57

Cross fault detection mode ❍ 63

Reset mode ❍ 62

OFF-delay time ❍ 65

Switching mode --- ---

External indicator fault diagnosis mode

--- ---

Safety Input

Safety Instantaneous

Output

Safety OFF-delayed

Output

Logical AND Connection

Output

Logical AND Connection

Input

No.OFF-DELAY

0.50.4

0.30.2 15

10754

321.510.6

0.7

0

S54S44S34S24S14 L1A2T42T41T22T21

A1X2X1Y1T12T11T33T31

T1

ERR

EI

AND

FB

ED

T2

PWR

T32

G9SX-AD322-T1524VDC

Marking Color Name

PWR Green Power supply indicator

T1 Orange Safety input #1 indicator

T2 Orange Safety input #2 indicator

FB Orange Feedback/reset input indicator

AND Orange Logical AND input indicator

EI Orange Safety output indicator

ED OrangeOFF-delayed safety output indicator

ERR Red Error indicator

No.OFF-DELAY

0.50.4

0.30.2 15

10754

321.510.6

0.7

0

S54S44S34S24S14 L1A2T42T41T22T21

A1X2X1Y1T12T11T33T31

T1

ERR

EI

AND

FB

ED

T2

PWR

T32

G9SX-AD322-T1524VDC

Page 41: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Functions of each Unit

G9SXUSER'S GUIDE 41

Fu

nctio

ns o

f G9S

XS

ection

2

■ G9SX-ADA@Safety Inputs

Safety Outputs (Semiconductor Outputs)

Note: The OFF-delayed outputs can be used as instantaneous outputs bysetting the OFF-delay time to 0 s.

Logical AND Connections

OFF-delay Time Setting

Required Settings and Wiring

LED Indicators

Safety inputs 1 input (2-channel input)

Safety input devicesEmergency stop switch, door switch, light curtain

Instantaneous outputs 2 outputs

OFF-delayed outputs 2 outputs

Number of inputs 2 inputs

Number of outputs 2 outputs

G9SX-ADA222-T15-@ 0 to 15 s

G9SX-ADA222-T150-@ 0 to 150 s

Item G9SX-ADA Page

Logical AND connection input enable/disable

❍ 57

Cross fault detection mode ❍ 63

Reset mode ❍ 62

OFF-delay time ❍ 65

Switching mode --- ---

External indicator fault diagnosis mode

--- ---

Safety Input

Safety Instantaneous

Output

Safety OFF-delayed

Output

Logical AND Connection

Output

Logical AND Connection

Input

No.OFF-DELAY

0.50.4

0.30.2 15

10754

321.510.6

0.7

0

L1S54S44S24S14 L2A2T42T41T22T21

A1X2X1Y1T12T11T33T31

T1

ERR

EI

AND1

FB

ED

T2

PWR

T32 T52T51

G9SX-ADA222-T15024VDC

AND2

Marking Color Name

PWR Green Power supply indicator

T1 Orange Safety input #1 indicator

T2 Orange Safety input #2 indicator

FB Orange Feedback/reset input indicator

AND1 Orange Logical AND input indicator

AND2 Orange Logical AND input indicator

EI Orange Safety output indicator

ED OrangeOFF-delayed safety output indicator

ERR Red Error indicator

No.OFF-DELAY

0.50.4

0.30.2 15

10754

321.510.6

0.7

0

L1S54S44S24S14 L2A2T42T41T22T21

A1X2X1Y1T12T11T33T31

T1

ERR

EI

AND1

FB

ED

T2

PWR

T32 T52T51

G9SX-ADA222-T15024VDC

AND2

Page 42: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Fu

nctio

ns o

f G9S

XS

ection

2

2. Functions of each Unit

42G9SX USER'S GUIDE

2-3 Non-Contact Door Switch ControllerThis is a Special Controller for D40A Non-contact Door Switch. It can be connected to other Units using the logical

AND connection input and output.

■ G9SX-NS@Safety Inputs

Safety Outputs (Semiconductor Outputs)

Logical AND Connections

Required Settings and Wiring

LED Indicators

Safety inputs 1 input (2-channel input)

Safety input devices Non-contact door switch (D40A)

Instantaneous outputs 2 outputs

OFF-delayed outputs None

Number of inputs 1 input

Number of outputs 1 output

Item G9SX-NS Page

Logical AND connection input enable/disable

❍ 57

Cross fault detection mode --- ---

Reset mode ❍ 62

OFF-delay time --- ---

Switching mode --- ---

External indicator fault diagnosis mode

--- ---

D40A Input

Safety Instantaneous

Output

Logical AND Connection

Output

Logical AND Connection

Input

No.

NS

FB

ERR

AND

EI

PWR

D4L1S24S14A2X2T42T41

A1X1D2D1D3T32 T33T31

G9SX-NS20224VDC

Marking Color Name

PWR Green Power supply indicator

NS OrangeNon-contact Door Switch input indicator

FB Orange Feedback/reset input indicator

AND Orange Logical AND input indicator

EI OrangeInstantaneous safety output indicator

ERR Red Error indicator

No.

NS

FB

ERR

AND

EI

PWR

D4L1S24S14A2X2T42T41

A1X1D2D1D3T32 T33T31

G9SX-NS20224VDC

Page 43: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Functions of each Unit

G9SXUSER'S GUIDE 43

Fu

nctio

ns o

f G9S

XS

ection

2

■ G9SX-NSA@Safety Inputs

Safety Outputs (Semiconductor Outputs)

Note: The OFF-delayed outputs can be used as instantaneous outputs bysetting the OFF-delay time to 0 s.

Logical AND Connections

OFF-delay Time Setting

Required Settings and Wiring

LED Indicators

Safety inputs 2 inputs (each with 2 channels)

Safety input devicesNon-contact door switch (D40A), emergency stop switch, door switch

Instantaneous outputs 2 outputs

OFF-delayed outputs 2 outputs

Number of inputs 1 input

Number of outputs 1 output

G9SX-NSA222-T03-@ 0 to 3 s

Item G9SX-NSA Page

Logical AND connection input enable/disable

❍ 57

Cross fault detection mode ❍ 63

Reset mode ❍ 62

OFF-delay time ❍ 65

Switching mode --- ---

External indicator fault diagnosis mode

--- ---

D40A Input Safety Input

Safety Instantaneous

Output

Safety OFF-delayed

Output

Logical AND Connection

Output

Logical AND Connection

Input

No.OFF-DELAY

L1S54S44S24S14 D4A2T42T41T22T21

A1X2X1Y1T12T11T33T31

T1

ERR

EI

AND

FB

ED

T2

PWR

T32 D2 D3D1

G9SX-NSA222-T3024VDC

NS

0.50.4

0.30.2 3.0

2.52.01.8

1.41.21.00.90.8

0.60.7

0

Marking Color Name

PWR Green Power supply indicator

T1 Orange Safety input #1 indicator

T2 Orange Safety input #2 indicator

NS OrangeNon-contact Door Switch input indicator

FB Orange Feedback/reset input indicator

AND Orange Logical AND input indicator

EI OrangeInstantaneous safety output indicator

ED OrangeOFF-delayed safety output indicator

ERR Red Error indicator

No.OFF-DELAY

L1S54S44S24S14 D4A2T42T41T22T21

A1X2X1Y1T12T11T33T31

T1

ERR

EI

AND

FB

ED

T2

PWR

T32 D2 D3D1

G9SX-NSA222-T3024VDC

NS

0.50.4

0.30.2 3.0

2.52.01.8

1.41.21.00.90.8

0.60.7

0

Page 44: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Fu

nctio

ns o

f G9S

XS

ection

2

2. Functions of each Unit

44G9SX USER'S GUIDE

2-4 Safety Guard Switching UnitThis Unit can alternately enable two safety inputs. It can be used to construct safety systems for semi-automatic processing and maintenance work.

■ G9SX-GS@Safety Inputs

Safety Outputs (Semiconductor Outputs)

Note: The OFF-delayed outputs can be used as instantaneous outputs bysetting the OFF-delay time to 0 s.

Logical AND Connections

OFF-delay Time Setting

Required Settings and Wiring

Note: Carefully read the Precautions on pages 96 to 99 before configuring a system using the G9SX-GS.

LED Indicators

Safety inputs 2 inputs (each with 2 channels)

Safety input devices Door switch, light curtain

Instantaneous outputs 2 outputs

OFF-delayed outputs 2 outputs

Number of inputs 1 input

Number of outputs 1 output

G9SX-GS226-T15-@ 0 to 15 s

Item G9SX-GS Page

Logical AND connection input enable/disable

❍ 57

Cross fault detection mode ❍ 63

Reset mode ❍ 62

OFF-delay time ❍ 65

Switching mode ❍ 67

External indicator fault diagnosis mode

❍ 68

Safety InputSafety Input

Safety Instantaneous

Output

Safety OFF-delayed

Output

Logical AND Connection

Output

Logical AND Connection

Input

T31 T32 T33T11

Y1 M1 M2T12 T61 T62 Y2 Y3

T21 T22X1 X2 X3 X4 S14 S24

T72T71 T41 T42

24VDC

T1

ERR

G9SX-GS226-T15

EI

T6

FB

ED

UA

PWR

OFF-DELAY

UB

0.2 00.3

0.40.5

0.60.7 1 1.5 2 3

457

1015

T2

T7

AND

UA UBY4 A1

S44 S54L1 A2

No.

Marking Color Name

PWR Green Power supply indicator

T1 Orange Safety input A, channel 1 indicator

T2 Orange Safety input A, channel 2 indicator

T6 Orange Safety input B, channel 1 indicator

T7 Orange Safety input B, channel 2 indicator

FB Orange Feedback/reset input indicator

AND Orange Logical AND input indicator

EI Orange Safety output indicator

ED Orange OFF-delayed safety output indicator

UA Orange Safety input A disabled state indicator

UB Orange Safety input B disabled state indicator

ERR Red Error indicator

T31 T32 T33T11

Y1 M1 M2T12 T61 T62 Y2 Y3

T21 T22X1 X2 X3 X4 S14 S24

T72T71 T41 T42

24VDC

T1

ERR

G9SX-GS226-T15

EI

T6

FB

ED

UA

PWR

OFF-DELAY

UB

0.2 00.3

0.40.5

0.60.7 1 1.5 2 3

457

1015

T2

T7

AND

UA UBY4 A1

S44 S54L1 A2

No.

Page 45: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Functions of each Unit

G9SXUSER'S GUIDE 45

Fu

nctio

ns o

f G9S

XS

ection

2

FunctionsAuto Switching Function

Manual Switching Function

When the operator inserts the workpiece... While the robot processes the workpiece...

Safety Light Curtain A Safety Light Curtain BSafety Light Curtain A

monitors the robot.

The robot can continue

to operate as long as it

does not interrupt Safety

Light Curtain A.

Safety Light Curtain B

monitors the operator.

The robot can continue

to operate as long as the

operator does not

interrupt Safety Light

Curtain B.

Note: If the operator is able to completely enter the zone inside Safety Light Curtain B, a presence detection device, such as a Safety Mat, is necessary as an additional safety measure.

Autoswitching

• •

• •

During normal operation... During maintenance...

Door Switch Limit Switch

The Door Switch monitors

the opening and closing of

the door during normal

operation.

The machine is able to

operate while the door is

closed.

The Limit Switch monitors

the conveyor cart position

during maintenance.

The machine is able to

operate while the

conveyor cart is in a

specified area.

Manual switchingNormal operation Maintenance

Page 46: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Fu

nctio

ns o

f G9S

XS

ection

2

2. Functions of each Unit

46G9SX USER'S GUIDE

Auto Switching Function

1

2

3

4

ON

ONON ON

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

ONON

ON

ONOFF

OFF

OFFOFF

OFF

(3) Safety Light Curtain B

(1) Emergency Stop Switch

(2) Safety Light Curtain A

(1) Emergency Stop Switch A22E

(2) Safety Light Curtain A (3) Safety Light Curtain B

Safety Light CurtainF3SJ

Safety Light CurtainF3SJ

Safety Guard Switching UnitG9SX-GS

Auxiliary Output

The auxiliary output can be used to notify operators of the input, output, or error status.

Programmable ControllersCS/CJ Series

External Indicator OutputThe external indicator output can be used to notify operators of Safety Light Curtains that may safely be interrupted.External

indicator BExternal indicator A

Contactor

Note: External indicator output may be used as necessary.

Basic UnitG9SX-BC

Logical AND connection

Saf

ety

Out

put

Robot

Moni-toring

Working condition G9SX-GSSafety input

External indicator

Safety input A

Safety input B

OK to work

Safety output

Safety output Monitor output External indicator

Input A monitor

Input B monitor

Input A monitor

Input B monitor

Input A monitor

Input B monitor

Input A monitor

Input B monitor

Safety input A

Safety input BSafety output

Safety input A

Safety input BSafety output

Safety input A

Safety input BSafety output

No

rmal

op

erat

ion

Haz

ardo

us c

ondi

tion

OK to work

Not OK to work

Not OK to work

Indicator A

Indicator B

Indicator A

Indicator B

Indicator A

Indicator B

Indicator A

Indicator B

Welding robot

Emergency Stop Switch

Conveying robot

Safety Light Curtain A

Safety Light Curtain B

Welding robot

Emergency Stop Switch

Conveying robot

Safety Light Curtain A

Safety Light Curtain B

Welding robot

Emergency Stop Switch

Conveying robot

Safety Light Curtain A

Safety Light Curtain B

Moni-toring

Welding robot

Emergency Stop Switch

Conveying robot

Safety Light Curtain A

Safety Light Curtain B

Page 47: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Functions of each Unit

G9SXUSER'S GUIDE 47

Fu

nctio

ns o

f G9S

XS

ection

2

Manual Switching Function

4

2

3

1

ON

ONOFF

ON

ON

OFF

ON

OFF

OFF

OFF

ONON

ONON

OFFOFF

OFF

Disa-bled

Disa-bled

Disa-bled

Disa-bled

Disa-bled

Basic UnitG9SX-BC

Logical AND connection

(1) Emergency Stop Switch A22E

(1) Emergency Stop Switch

(3) Safety Limit Switch

(2) Safety Door Switch

(4) Mode selector

Saf

ety

outp

ut

Safety Limit SwitchD4F

Key-type Selector Switch A22K

Safety Door SwitchD4NS

Safety Guard Switching UnitG9SX-GS

(2) Cover (3) Conveyor cart

Conveyor cart

(4) Mode selector

Auxiliary Output

The auxiliary output can be used to notify operators of the input, output, or error status.

External Indicator OutputThe external indicator output can be used to notify operators that the cover may be opened.

Contactor

Note: External indicator output may be used as necessary.

External indicator A

External indicator B

Programmable ControllersCS/CJ Series

Normal operating mode

Working condition G9SX-GSSafety input

External indicator

Safety input A

Safety input BSafety output

Safety output Monitor outputMode selector External indicator

Input A monitor

Input B monitor

Input A monitor

Input B monitor

Input A monitor

Input B monitor

Input A monitor

Input B monitor

Safety input A

Safety input BSafety output

Safety input A

Safety input BSafety output

Safety input A

Safety input BSafety output

No

rmal

op

erat

ion

Mai

nte

nan

ceH

azar

dous

con

ditio

n

Maintenance mode

Maintenance mode

Maintenance mode

Not OK to open

OK to open

OK to open

OK to open

Indicator A

Indicator B

Indicator B

Indicator A

Indicator B

Indicator A

Indicator B

Indicator A

Emergency Stop Switch

Mode selector

Limit Switch

Door Switch

Disa-bled

Moni-toring

Emergency Stop Switch

Mode selector

Limit Switch

Door Switch

Emergency Stop Switch

Mode selector

Limit Switch

Door Switch

Emergency Stop Switch

Mode selector

Limit Switch

Door Switch

Moni-toring

Disa-bled

Moni-toring

Disa-bled

Moni-toring

Disa-bled

Page 48: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Fu

nctio

ns o

f G9S

XS

ection

2

2. Functions of each Unit

48G9SX USER'S GUIDE

2-5 Expansion UnitBy connecting an Expansion Unit to the G9SX-AD/ADA, G9SX-NSA, or G9SX-GS, safety relay contact outputs can

be added that are synchronized with the safety outputs of the Unit to which the Expansion Unit is connected.

■ G9SX-EX-@Safety Outputs (Safety Relay Outputs)

Logical AND Connections

Required Settings and Wiring

Note: Refer to 2-10 Connecting Expansion Units on page 69.

LED Indicators

Instantaneous outputs 4 outputs

OFF-delayed outputs None

Number of inputs None

Number of outputs None

Item G9SX-EX Page

Logical AND connection input enable/disable

--- ---

Cross fault detection mode --- ---

Reset mode --- ---

OFF-delay time --- ---

Switching mode --- ---

External indicator fault diagnosis mode

--- ---

G9SX-ADG9SX-ADAG9SX-NSAG9SX-GSG9SX-EX

G9SX-EX

Insert theconnector

Insert theconnector

Safety Instantaneous

Output

Marking Color Name

PWR Green Power supply indicator

EI Orange Safety output indicator

ERR Red Error indicator

PWR

EI

ERR

Page 49: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Functions of each Unit

G9SXUSER'S GUIDE 49

Fu

nctio

ns o

f G9S

XS

ection

2

■ G9SX-EX-T@Safety Outputs (Safety Relay Outputs)

Logical AND Connections

Required Settings and Wiring

Note: 1. The OFF-delay time on G9SX-EX-T is set from the OFF-delaypreset time on the connected unit (G9SX-AD/-ADA/-NSA/-GS).

2. Refer to 2-10 Connecting Expansion Units on page 69.

LED Indicators

Instantaneous outputs None

OFF-delayed outputs 4 outputs

Number of inputs None

Number of outputs None

Item G9SX-EX-T Page

Logical AND connection input enable/disable

--- ---

Cross fault detection mode --- ---

Reset mode --- ---

OFF-delay time --- (See note) 65

Switching mode --- ---

External indicator fault diagnosis mode

--- ---

G9SX-ADG9SX-ADAG9SX-NSAG9SX-GSG9SX-EX

G9SX-EX

Insert theconnector

Insert theconnector

Safety OFF-delayed

Output

G9SX-EX041-T

Marking Color Name

PWR Green Power supply indicator

ED OrangeOFF-delayed safety output indicator

ERR Red Error indicator

PWR

ED

ERR

G9SX-EX041-T

Page 50: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

MEMO

50G9SX USER'S GUIDE

Page 51: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 51

Wirin

g an

d S

etup

Sectio

n 3

Section 3

Wiring and Setup

1. I/O Terminals 52

1-1 Basic Unit 52

1-2 Advanced Unit 53

1-3 Non-contact Door Switch Controller 54

1-4 Safety Guard Switching Unit 55

1-5 Expansion Unit 56

2. Functions, Wiring and Settings 57

2-1 Logical AND Connection 57

2-2 Response Time and Operation Time 60

2-3 Reset Mode 62

2-4 Cross Fault Detection 63

2-5 Connecting Safety Sensors and the G9SX 64

2-6 OFF-delay Time 65

2-7 Non-contact Door Switch 66

2-8 Switching Mode 67

2-9 External Indicator Fault Diagnosis 68

2-10 Connecting Expansion Units 69

2-11 Confirming Settings 70

Page 52: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

52G9SX USER'S GUIDE

Wirin

g an

d S

etup

Sectio

n 3

1. I/O Terminals

1-1 Basic Unit

G9SX-BC

Note: 1. Internal power supply circuit is not isolated.2. Outputs S14 and S24 are internally redundant.

Signal name Terminal name Wiring

Power supply inputs A1, A2

Connect the power supply plus (24 VDC) to the A1 terminal.Connect the power supply minus (GND) to the A2 terminal.

Safety inputs T11, T12, T21, T22Refer to 2-4 Cross Fault Detection and 2-5 Connecting Safety Sensors and the G9SX.

Feedback/reset inputs T31, T32, T33 Refer to 2-3 Reset Mode.

Cross fault detection input Y1 Refer to 2-4 Cross Fault Detection.

Instantaneous safety outputs S14, S24 Keep these outputs open when they are not used.

Logical AND connection output L1, L2 Refer to 2-1 Logical AND Connection.

Auxiliary monitor outputs X1, X2 Keep these outputs open when they are not used.

(See note 1.)

Reset/Feedback Input

Crossfault

detectioninput

S14A2 S24 L1 L2 X1 X2

Power supply circuit

Safety Input 1

SafetyInput 2

Safety outputs control Auxiliary outputs control

T11A1 T12 T21 T22 T31 T32 T33 Y1

(See note 2.)

Page 53: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. I/O Terminals

G9SXUSER'S GUIDE 53

Wirin

g an

d S

etup

Sectio

n 3

1-2 Advanced Unit

G9SX-AD

Note: 1. Internal power supply circuit is not isolated.2. Logical AND input is isolated.3. Outputs S14 to S54 are internally redundant.

G9SX-ADA

Note: 1. Internal power supply circuit is not isolated.2. Logical AND input is isolated.3. Outputs S14 to S54 are internally redundant.

Signal name Terminal name Wiring

Power supply inputs A1, A2

Connect the power supply plus (24 VDC) to the A1 terminal.Connect the power supply minus (GND) to the A2 terminal.

Safety inputs T11, T12, T21, T22Refer to 2-4 Cross Fault Detection and 2-5 Connecting Safety Sensors and the G9SX

Feedback/reset inputs T31, T32, T33 Refer to 2-3 Reset Mode.

Logical AND connection inputs T41, T42, T51, T52 Refer to 2-1 Logical AND Connection.

Cross fault detection input Y1 Refer to 2-4 Cross Fault Detection.

Instantaneous safety outputs S14, S24, S34 Keep these outputs open when they are not used.

OFF-delayed safety outputs S44, S54 Keep these outputs open when they are not used.

Logical AND connection output L1, L2 Refer to 2-1 Logical AND Connection.

Auxiliary monitor outputs X1, X2 Keep these outputs open when they are not used.

(See note 1.) (See note 2.)

S14A2 S24 S34 S44 S54 L1 X1 X2

Power supply circuit

Safety Input 1

Safety Input 2

Reset/Feedback Input

Cross fault

detection input

Safety output control Auxiliary output control

Logical AND input

Expansion Unit output control

T11A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42

(See note 3.)

(See note 1.)

(See note 2.)

S14A2 S24 S44 S54 L1 L2 X1 X2

Power supply circuit

Safety Input 1

Safety Input 2

Reset/Feedback Input

Cross fault

detection input

Safety output control Auxiliary output control

Logical AND input

Expansion Unit output control

T11A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42

(See note 3.)

T51 T52

Logical AND input 2

Page 54: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Wirin

g an

d S

etup

Sectio

n 3

1. I/O Terminals

54G9SX USER'S GUIDE

1-3 Non-contact Door Switch Controller

G9SX-NS

Note: 1. Internal power supply circuit is not isolated.2. Logical AND input is isolated.3. Outputs S14 to S24 are internally redundant.

G9SX-NSA

Note: 1. Internal power supply circuit is not isolated.2. Logical AND input is isolated.3. Outputs S14 to S54 are internally redundant.

Signal name Terminal name Wiring

Power supply inputs A1, A2

Connect the power supply plus (24 VDC) to the A1 terminal.Connect the power supply minus (GND) to the A2 terminal.

Safety inputs T11, T12, T21, T22Refer to 2-4 Cross Fault Detection and 2-5 Connecting Safety Sensors and the G9SX.

Non-contact Door Switch (D40A) inputs D1, D2, D3, D4 Refer to 2-7 Non-contact Door Switch.

Feedback/reset inputs T31, T32, T33 Refer to 2-3 Reset Mode.

Logical AND connection inputs T41, T42 Refer to 2-1 Logical AND Connection.

Cross fault detection input Y1 Refer to 2-4 Cross Fault Detection.

Instantaneous safety outputs S14, S24 Keep these outputs open when they are not used.

OFF-delayed safety outputs S44, S54 Keep these outputs open when they are not used.

Logical AND connection output L1 Refer to 2-1 Logical AND Connection.

Auxiliary monitor outputs X1, X2 Keep these outputs open when they are not used.

(See note 3.)

(See note 2.)

Logical AND input

Safety output controlAuxiliary

output control

Reset/FeedbackInput

Non-contact Door Switch control

Power supply circuit (See note 1.)

D1 D2

X1L1A2 X2S24S14

D3 D4 T31 T32 T33 T41 T42A1 A1

A2

T11

S14 S24 S44 S54 L1 X1 X2

T12 T21 T22 T31 T32 T33 Y1 D1 D2 D3 D4 T41 T42

Power supply circuit (See note 1.)

(See note 3.)

Safety input 1

Safety output controlAuxiliary output control

Expansion Unit output control

Safety input 2

Reset/Feedback Input

Cross fault detection input

Logical AND input

(See note 2.)

Non-contact Door Switch control

Page 55: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. I/O Terminals

G9SXUSER'S GUIDE 55

Wirin

g an

d S

etup

Sectio

n 3

1-4 Safety Guard Switching Unit

G9SX-GS

Note: 1. Internal power supply circuit is not isolated.2. Logical AND input is isolated.3. Outputs S14 to S54 and L1 are internally redundant.

Signal name Terminal name Wiring

Power supply inputs A1, A2

Connect the power supply plus (24 VDC) to the A1 terminal.Connect the power supply minus (GND) to the A2 terminal.

Safety inputs A T11, T12, T21, T22 Refer to 2-4 Cross Fault Detection and 2-5 Connecting Safety Sensors and the G9SX.Safety inputs B T61, T62, T71, T72

Mode switching inputs M1, M2 Refer to 2-8 Switching Mode.

Feedback/reset inputs T31, T32, T33 Refer to 2-3 Reset Mode.

Logical AND connection inputs T41, T42 Refer to 2-1 Logical AND Connection.

Cross fault detection inputs Y1, Y2 Refer to 2-4 Cross Fault Detection.

Instantaneous safety outputs S14, S24 Keep these outputs open when they are not used.

OFF-delayed safety outputs S44, S54 Keep these outputs open when they are not used.

Logical AND connection output L1 Refer to 2-1 Logical AND Connection.

Auxiliary monitor outputs X1, X2, X3, X4 Keep these outputs open when they are not used.

External indicator outputs UA, UB Refer to 2-9 External Indicator Fault Diagnosis.

External indicator diagnosis switching inputs

Y3, Y4 Refer to 2-9 External Indicator Fault Diagnosis.

(Seenote2.)

S14A2 S24 S44 S54 L1 X1 X2 X3 X4 UA UB

Safety output control Auxiliary output control Expansion Unitoutput control

T11A1 T12 T21 T22 Y1 M1 M2 T61 T62 T71 T72 Y2 Y3 Y4 T31 T32 T33 T41 T42

Logical AND input

Reset/feedback input

External indicator diagnosis

switching input

Safety input BCh. 2

Safety input BCh. 1

Mode selector input

Safety input ACh. 2

Safety input ACh. 1

External indicator output control

Powersupplycircuit(Seenote 1.)

(See note 3.)

Cross fault

detection input B

Cross fault

detection input A

Page 56: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Wirin

g an

d S

etup

Sectio

n 3

1. I/O Terminals

56G9SX USER'S GUIDE

1-5 Expansion Unit

Note: The safety outputs are instantaneous safety outputs for the G9SX-EX401, and OFF-delayed safety outputs for the G9SX-EX041-T.

G9SX-EX401/G9SX-EX041-T

Note: 1. Internal power supply circuit is not isolated.2. Relay outputs are isolated.

Signal name Terminal name Wiring

Power supply inputs A1, A2

Connect the power supply plus (24 VDC) to the A1 terminal.Connect the power supply minus (GND) to the A2 terminal.

Safety outputs (See note.) 13-14, 23-24, 33-34, 43-44 Keep these outputs open when not used.

A2 X2

Power supply circuit Auxiliary

output control

Safety output control

A1

K1

13 23 33 43

14 24 34 44

K2

Exp. sig.IN

Exp.sig.

OUT

(See note 1.) (See note 2.)

Page 57: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 57

Wirin

g an

d S

etup

Sectio

n 3

2. Functions, Wiring and Settings

2-1 Logical AND ConnectionWhen connecting two or more Units using a logical AND connection, the logical AND connection setting is

performed on the Unit on the input side. Set the logical AND connection preset switch on the Unit that is on the input

side (G9SX-AD322 in the below diagram) to AND.

1. When the G9SX-AD/-NS/-NSA/-GS Is on the Input Side

Note: 1. In the above diagram, a setting error will occur and G9SX-AD322 will set a lock out if the logical AND setting switch on G9SX-AD322 is set to OFF.Set the switch carefully.

2. Set the logical AND setting switch on Unit A to OFF.3. A logical AND input cannot be input to the G9SX-BC.

2. When the G9SX-ADA Is on the Input Side

Note: 1. When not connecting Unit B, leave terminals T41 and T42 of the G9SX-ADA222 Unit open, and set the logical AND setting switch T41/T42 to OFF.2. When not connecting Unit C, leave terminals T51 and T52 of the G9SX-ADA222 Unit open, and set the logical AND setting switch to OFF.

When connecting multiple Units to the input side, follow the wiring example in the following diagram.

Note: When a logical AND connection is not used, keep the logical AND connection inputs (terminals T41, T42, T51, and T52) and logical AND connectionoutputs (terminals L1 and L2) open, and set the logical AND setting switch to OFF.

G9SX-AD322

Unit A

L1 A2

T41 T42

AND

OFF

AND

OFF

G9SX-ADA222

Unit B

L1 A2

T41 T42

Unit C

L1 A2

T51 T52

T41/T42 T51/T52

AND

OFF

AND

OFF

AND

OFF

AND

OFF

G9SX-BC202 orG9SX-AD322-T

L1 A2

G9SX-AD322-T

L1

T41 T42

A2

A2

G9SX-AD322-T

Logical AND connection signal(1st stage)

Logical AND connection signal(2nd stage) Next unit (4 unit max.)

Next unit (5 layers max.)

T41 T42

G9SX-AD322-T

L1

T41 T42

Next unit (4 unit max.)

Input b

Input a

Output (a)

Output (a&b)

Unit B

Unit A

Page 58: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Wirin

g an

d S

etup

Sectio

n 3

2. Functions, Wiring and Settings

58G9SX USER'S GUIDE

3. Logical AND Connection Combinations(1 ) One logical AND connection output from an Advanced Unit G9SX-AD can be logical AND connected to up to

four Advanced Units.

(2 ) Two logical AND outputs from a Basic Unit G9SX-BC can be logical AND connected to up to eight Advanced

Units.

(3 ) Two logical AND outputs from an Advanced Unit G9SX-ADA can be logical AND connected to up to eight

Advanced Units.

(4 ) Any Advanced Unit with logical AND input can be logical AND connected to Advanced Units on up to five tiers.

G9SX-AD

G9SX-ADG9SX-ADG9SX-ADG9SX-AD

G9SX-BC

G9SX-AD

G9SX-ADG9SX-ADG9SX-ADG9SX-AD

G9SX-AD G9SX-AD G9SX-AD

G9SX-AD

G9SX-ADG9SX-ADG9SX-ADG9SX-AD

G9SX-ADA

G9SX-AD G9SX-AD G9SX-AD

Advanced Unitor Basic Unit

G9SX-AD

G9SX-AD

G9SX-AD

G9SX-AD

Page 59: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Functions, Wiring and Settings

G9SXUSER'S GUIDE 59

Wirin

g an

d S

etup

Sectio

n 3

(5 ) Two logical AND connection outputs, each from different Advanced/Basic Units, can be logical AND connected

to a single G9SX-ADA Unit.

(6 ) The largest possible system configuration contains a total of 20 Advanced and Basic Units. In this configuration,

each Advanced Unit can have up to five Expansion Units.

Note: The section on Advanced Units, above, can also be replaced with G9SX-NS/-NSA/-GS.

G9SX-BC G9SX-BC

G9SX-ADA

Number of Units connected per logical AND output:4 Units max.

Total number of Units connected by logical AND: 20 Units max.

Number of Units connected in series by logical AND:5 Units max.

Note 1: Basic Unit = G9SX-BC Advanced Unit = G9SX-AD or G9SX-ADANote 2: The G9SX-AD322-T-@ has only one logical AND output.

Advanced Unitor Basic Unit

Advanced UnitAdvanced Unit Advanced Unit Advanced Unit

Advanced Unit Advanced Unit Advanced Unit Advanced Unit

Advanced Unit Advanced Unit Advanced Unit

Advanced Unit Advanced Unit Advanced Unit Advanced Unit

Advanced Unit Advanced Unit Advanced Unit

Advanced Unit

Page 60: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Wirin

g an

d S

etup

Sectio

n 3

2. Functions, Wiring and Settings

60G9SX USER'S GUIDE

2-2 Response Time and Operation Time(1) G9SX-BC

(2) G9SX-AD/ADA

(3) G9SX-NS

(4) G9SX-NSA

Note: 1. The maximum response time is the time it takes the output to turn OFF after the input turns OFF.2. The maximum operating time is the time it takes the output to turn ON after the input turn ON.

Safety input Max. response time (excluding Expansion Units)

(See note 1.)

Max. operating time (excluding Expansion Units)

(See note 2.)

Safety input 15 ms 50 ms

Safety inputD4NS

Logical ANDconnection input

Max. response time (excluding Expansion Units)

(See note 1.)

Max. operating time (excluding Expansion Units)

(See note 2.)

Safety input 15 ms 50 ms

Logical AND connection input

15 ms 100 ms

Non-contact DoorSwitch inputD40A

Logical ANDconnection input

Max. response time (excluding Expansion Units)

(See note 1.)

Max. operating time (excluding Expansion Units)

(See note 2.)

Non-contact Door Switch input

20 ms 100 ms

Logical AND connection input

15 ms 100 ms

Safety InputD4NS

Logical ANDconnection input

Non-contact DoorSwitch inputD40A

Max. response time (excluding Expansion Units)

(See note 1.)

Max. operating time (excluding Expansion Units)

(See note 2.)

Non-contact Door Switch input

20 ms 100 ms

Safety input 15 ms 50 ms

Logical AND connection input

15 ms 100 ms

Page 61: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Functions, Wiring and Settings

G9SXUSER'S GUIDE 61

Wirin

g an

d S

etup

Sectio

n 3

(5) G9SX-GS

Note: 1. The maximum response time is the time it takes the output to turn OFF after the input turns OFF.2. The maximum operating time is the time it takes the output to turn ON after the input turn ON.3. The maximum response time exists when safety input A or safety input B is enabled.

(6) When two or more Units are connected using a logical AND connection.

Safety Input BD4NS

Logical ANDconnection input

Safety Input AD4NS

Max. response time (excluding Expansion Units)

(See note 1.)

Max. operating time (excluding Expansion Units)

(See note 2.)

Safety input A 15 ms (See note 3.) 50 ms

Safety input B 15 ms (See note 3.) 50 ms

Logical AND connection input

15 ms 100 ms

D40A

Safety Output (2)

Safety Output (3)

Logical ANDConnection

(2)

Logical ANDConnection

(1)

Safety InputD4NS (1)

Safety InputD4NS (2)

Safety Output (1)

Safety InputA22E

Case 1

Response Time from When A22E Turns OFF until Safety Output 2

Turns OFF

Case 2

Response Time from When D40A Turns OFF until Safety Output 3

Turns OFF

Case 3

Response Time from When A22E Turns OFF until Safety Output 3

Turns OFF

Note: The operation time is calculated in a similar fashion.

15 ms + 15 ms = 30 ms(A22E) (Logical AND

Connection (1))

20 ms + 15 ms = 35 ms(D40A) (Logical AND

Connection (2))

15 ms + 15 ms + 15 ms = 45 ms(A22E) (Logical AND

Connection (1))

(Logical AND

Connection (2))

Page 62: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Wirin

g an

d S

etup

Sectio

n 3

2. Functions, Wiring and Settings

62G9SX USER'S GUIDE

2-3 Reset ModeSet the reset mode using feedback/reset input terminals T31, T32, and T33.

Reset mode Wiring Function summary

Auto reset mode

The signal to terminal T33 must be ON for the safety output to turn ON.If terminal T33 is not ON, the safety output will not turn ON.

Manual reset mode

The signal to terminal T32 must turn ON and then OFF for the safety output to turn ON.If terminal T32 does not turn ON and then OFF, the safety output will not turn ON.

+24 V

KM1

KM2

KM3

KM4

KM5

T33T32T31

Feedback Loop

KM1

KM2

KM3

KM4

KM5

T33T32T31

Feedback Loop

+24 V

Reset switch

Page 63: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Functions, Wiring and Settings

G9SXUSER'S GUIDE 63

Wirin

g an

d S

etup

Sectio

n 3

2-4 Cross Fault DetectionThe cross fault detection setting for the safety input is made using the cross fault detection input (terminals Y1 and

Y2).

If a fault is detected, the following will occur.

1. The safety outputs and logical AND outputs will be locked out.

2. The LED error indicator will be lit.

3. The error output (auxiliary output) will turn ON.

For wiring, refer to the following description.

(1 ) Cross Fault between T11-T12 and T21-T22

Cross fault detection mode Cross fault detection input

ON Open

OFF Connect to +24 V

Cross fault detection input Safety input to be monitored Function summary

Terminal Y1 Terminals T11-T12 and T21-T22 Detects cross faults across T11-T12 and T21-T22

Terminal Y2 Terminals T61-T62 and T71-T72 Detect cross faults in T61-T62 and T71-T72

Cross faultdetection

Wiring

OFF

Corresponds to Safety Category 2

Corresponds to Safety Category 3

ONCorresponds to

Safety Category 4

Y1T22T21T12T11

S1

+24 V

+24 V

Y1T22T21T12T11

S1

+24 V

+24 V +24 V

NCY1T22T21T12T11

S1

Page 64: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Wirin

g an

d S

etup

Sectio

n 3

2. Functions, Wiring and Settings

64G9SX USER'S GUIDE

2-5 Connecting Safety Sensors and the G9SX(1 ) When connecting safety sensors to the G9SX, the Y1 terminal must be connected to 24 VDC.

The G9SX will detect a connection error, if the Y1 terminal is open.

(2 ) In many cases, safety sensor outputs include an OFF-shot pulse for self diagnosis.

The following condition of test pulse is applicable as safety inputs for the G9SX.

• OFF-shot pulse width of the sensor, during the ON-state: 340 μs max.

340 µs max.

Page 65: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Functions, Wiring and Settings

G9SXUSER'S GUIDE 65

Wirin

g an

d S

etup

Sectio

n 3

2-6 OFF-delay TimeThe safety output preset time is set using the OFF-delay time preset switch (1 each on the front and back of the

Unit).

Note: 1. Normal operation will occur only if both switches are set to the same setting.An error will occur if both switches are not identically set.

2. If the preset time is set to 0 seconds, the output function as an instantaneous safety output.

Refer to the following illustration for details on setting switch positions.

1. G9SX-AD322-T15

2. G9SX-AD322-T150

Front Back

Switch

Switch

OFF-DELAY

0.50.4

0.30.2 15

10754

321.510.6

0.7

0

OFF-DELAY

0.50.4

0.30.2 15

10754

321.510.6

0.7

0

Notch

Example 2: 1-second OFF-delay setting

Example 1: 0-second OFF-delay setting

4030

2010 150

140130120110

10090807050

60

0

4030

2010 150

140130120110

10090807050

60

0

OFF-DELAY OFF-DELAYNotch

Example 1: 0-second OFF-delay setting

Example 2: 70-second OFF-delay setting

Page 66: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Wirin

g an

d S

etup

Sectio

n 3

2. Functions, Wiring and Settings

66G9SX USER'S GUIDE

2-7 Non-contact Door SwitchExample: Wiring a Single Switch

Note: The auxiliary output load current must be 10 mA max.

Example: Wiring Multiple SwitchesConnect Up to 30 Non-contact Door Switches.

Wiring of Inputs and Outputs

Signal name Wire color Description of operation

Non-contact Door Switch power supply input

Brown Supplies power to the D40A.Connect to the D3 and D4 terminals of the [email protected]

Non-contact Door Switch input WhiteInputs signals from the [email protected] Non-contact Door Switch input must be ON as a required condition for the Non-contact Door Switch output to be ON.

Non-contact Door Switch output

BlackTurns ON and OFF according to actuator detection and the status of the Non-contact Door Switch input.

Auxiliary output Yellow Turns ON when actuator is detected.

Bla

ck

Bro

wn

Whi

te

Blu

e

Yello

w

G9SX-NS202-@G9SX-NSA222-T03-@

Auxiliary output load(See note.)

D40A-1C@

D1 D2 D3 D4 A2

G9SX-NS202-@G9SX-NSA222-T03-@

D1 D2 D3 D4

Bla

ck

Bro

wn

Whi

te

Blu

e

Bla

ck

Bro

wn

Whi

te

Blu

e

Bla

ck

Bro

wn

Whi

te

Blu

e

Page 67: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Functions, Wiring and Settings

G9SXUSER'S GUIDE 67

Wirin

g an

d S

etup

Sectio

n 3

2-8 Switching ModeThe switching mode is set by using the Switching Function setting switch on the bottom of the G9SX Unit. Set the

switch to Auto for auto switching and Manual for manual switching.

For manual switching, connect the mode selector as shown in the following table.

Switching Mode Switching Function setting switch Mode selector connection

Auto switching

Manual switching

M1 ON, M2 OFF: Normal operating modeM1 OFF, M2 ON: Maintenance mode

Manual

AutoM2M1

NCNC

Manual

Auto M2M1

+24V

Maintenancemode

Normaloperatingmode

Page 68: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Wirin

g an

d S

etup

Sectio

n 3

2. Functions, Wiring and Settings

68G9SX USER'S GUIDE

2-9 External Indicator Fault DiagnosisDiagnostic checks of external indicators connected to the G9SX-GS's external indicator outputs UA and UB can be

switched with Y3 and Y4, respectively.

Note: 1. If there is no indicator connected to external indicator output UA, connect Y3 to 24 V. If there is no indicator connected to external indicator outputUB, connect Y4 to 24 V. If they are not connected to 24 V, the G9SX-GS will detect an error.

2. Diagnostic checks cannot be made for LED indicators. Disable the diagnostic check if using LED indicators.

External indicator output

Diagnostic check enabled Diagnostic check disabled

UA

UB

NC

Y3

UA

Indicator

+24V

Indicator

Y3

UA

NC

Y4

UB

Indicator

+24V

Indicator

Y4

UB

Page 69: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Functions, Wiring and Settings

G9SXUSER'S GUIDE 69

Wirin

g an

d S

etup

Sectio

n 3

2-10 Connecting Expansion Units• G9SX-EX/G9SX-EX-T Expansion Units can be connected to the G9SX-AD/-ADA Advanced Unit, G9SX-NSA

Non-contact Door Switch Controller, or G9SX-GS Safety Guard Switching Unit to increase the number of safety

outputs. (Expansion Units cannot be connected to the G9SX-BC or to the G9SX-NS Non-contact Door Switch

Controller.)

• A maximum of five Expansion Units can be connected to one Advanced Unit. This may be a combination of

G9SX-EX Instantaneous types and G9SX-EX-T OFF-delayed types.

• Remove the end connector from the Unit (G9SX-AD, G9SX-ADA, G9SX-NSA, or G9SX-GS) and insert the

connector on the Connecting Cable from the first Expansion Unit. Place the end connector that was removed from

the Unit on the last Expansion Unit (i.e., the rightmost Expansion Unit).

• When Expansion Units are connected to an Advanced Unit, make sure that power is supplied to every Expansion

Unit. (Refer to the following diagram for actual Expansion Unit connection.)

Expansion Unit

Terminatingconnector

Advanced UnitG9SX-AD/-ADA/-NSA/-GS

Page 70: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

70G9SX USER'S GUIDE

Wirin

g an

d S

etup

Sectio

n 3

2-11 Confirming Settings

Settings for the G9SX can be checked by the orange indicators for approx. 3 seconds after the power is turned ON.

During this settings indication period, the ERR indicator will light, however the auxiliary error output will remain OFF.

G9SX-AD/-ADA/-BC/-NS/-NSA

Note: Except for the G9SX-BC and G9SX-NS.

G9SX-GS

Indicator Item Setting positionIndicator

statusSetting mode Setting status

T1Cross fault detection mode

Y1 terminalLit Detection mode Y1 = open

Not lit Non-detection mode Y1 = 24 VDC

FB Reset modeT33 or T32 terminal

Lit Manual reset mode T33 = 24 VDC

Not lit Auto reset mode T32 = 24 VDC

AND (AND1, AND2)

Logical AND connection input mode (See note.)

Logical AND connection preset switch

Lit Enable logical AND input "AND"

Not lit Disable logical AND input "OFF"

Indicator Item Setting positionIndicator

statusSetting mode Setting status

T1Cross fault detection mode for safety input A

Y1 terminalLit Enabled Y1 = open

Not lit Disabled Y1 = 24 VDC

T6Cross fault detection mode for safety input B

Y2 terminalLit Enabled Y2 = open

Not lit Disabled Y2 = 24 VDC

FB Reset modeT33 or T32 terminal

Lit Manual reset mode T33 = 24 VDC

Not lit Auto reset mode T32 = 24 VDC

ANDLogical AND connection input mode

Logical AND connection preset switch

Lit Enabled "AND"

Not lit Disabled "OFF"

UA, UB Switching FunctionSwitching Function setting switch

Lit Manual switching "Manual"

Not lit Auto switching "Auto"

Page 71: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 71

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

Section 4Ratings and

Specifications

1. Ratings 72

1-1 Advanced Unit/Basic Unit 72

1-2 Non-contact Door Switch Controller 73

1-3 Safety Guard Switching Unit 74

1-4 Expansion Unit 75

2. Characteristics 76

2-1 Advanced Unit/Basic Unit 76

2-2 Non-contact Door Switch Controller 77

2-3 Safety Guard Switching Unit 78

2-4 Expansion Unit 79

3. Dimensions and Terminal arrangements 80

3-1 Advanced Unit 80

3-2 Basic Unit 80

3-3 Non-contact Door Switch Controller 81

3-4 Safety Guard Switching Unit 81

3-5 Expansion Unit 82

Page 72: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

72G9SX USER'S GUIDE

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

1. Ratings

1-1 Advanced Unit/Basic UnitPower input

Note: Power consumption of loads not included.

Inputs

Note: Provide a current equal to or higher than that of the minimum applicable load of the connected input control device.

Outputs

Note: 1. While safety outputs are in the ON state, the following signal sequence is output continuously for diagnosis. When using the safety outputs as inputsignals to control devices (i.e. Programmable Controllers), consider the OFF pulse shown below.

2. The following derating is required when Units are mounted side-by-side. G9SX-AD322-@/G9SX-ADA222-@/G9SX-BC202-@: 0.4 A DC max. load current

Item Model G9SX-AD322-@/ADA222-@ G9SX-BC202-@

Rated supply voltage 24 VDC

Operating voltage range −15% to 10% of rated supply voltage

Rated power consumption (See note.) 4 W max. 3 W max.

Item Model G9SX-AD322-@/ADA222-@ G9SX-BC202-@

Safety inputOperating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kΩ (See note.)

Feedback/reset input

Item Model G9SX-AD322-@/ADA222-@ G9SX-BC202-@

Instantaneous safety output(See note 1.)OFF-delayed safety output(See note 1.)

P channel MOS FET transistor outputLoad current:

Using 2 outputs or less: 1 A DC max. (See note 2.)Using 3 outputs or more: 0.8 A DC max.

P channel MOS FET transistor outputLoad current:

Using 1 output: 1 A DC max. (See note 2.)Using 2 outputs: 0.8 A DC max.

Auxiliary outputPNP transistor outputLoad current: 100 mA max.

ON

OFF

Approx. 100 ms

360 µs max.

Page 73: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. Ratings

G9SXUSER'S GUIDE 73

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

1-2 Non-contact Door Switch ControllerPower input

Note: Power consumption of loads not included.

Inputs

Note: 1. Only applies to the G9SX-NSA222-T03-@. Refers to input other than that from the Non-contact Door Switch.2. Provide a current equal to or higher than that of the minimum applicable load of the connected input control device.

Outputs

Note: 1. While safety outputs are in the ON state, the following signal sequence is output continuously for diagnosis.When using the safety outputs as input signals to control devices (i.e. Programmable Controllers), consider the OFF pulse shown below.

2. The following derating is required when Units are mounted side-by-side.G9SX-NS202-@/G9SX-NSA222-T03-@: 0.4 A DC max. load current

3. Apply the following rated load conditions for inductive loads.IEC/EN 60947-5-1 DC13: 0.8 AUL508 Pilot Duty: 0.5 A

Item Model G9SX-NS202-@ G9SX-NSA222-T03-@

Rated supply voltage 24 VDC

Operating voltage range −15% to 10% of rated supply voltage

Rated power consumption (See note.) 3 W max. 4 W max.

Item Model G9SX-NS202-@/G9SX-NSA222-T03-@

Safety input (See note 1.)Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8kΩ (See note 2.)

Feedback/reset input

Item Model G9SX-NS202-@/G9SX-NSA222-T03-@

Instantaneous safety output(See note 1.)OFF-delayed safety output(See note 1.)

P channel MOS FET transistor outputLoad current: 0.8 A DC max. (See note 2 and 3.)

Auxiliary outputPNP transistor outputLoad current: 100 mA max.

ON

OFF

360 µs max.

Approx.100 ms

Page 74: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

1. Ratings

74G9SX USER'S GUIDE

1-3 Safety Guard Switching UnitPower Input

Note: Power consumption of loads not included.

Inputs

Note: Provide a current equal to or higher than that of the minimum applicable load of the connected input control device.

Outputs

Note: 1. While safety outputs are in the ON state, the following signal sequence is output continuously for diagnosis. When using the safety outputs as input signals to control devices (i.e. Programmable Controllers), consider the OFF pulse shown below.

2. The following derating is required when Units are mounted side-by-side. G9SX-GS226-T15-@: 0.4 A DC max. load current

3. Apply the following rated load conditions for inductive loads.IEC/EN 60947-5-1 DC13: 0.8 AUL508 Pilot Duty: 0.5 A

Item Model G9SX-GS226-T15-@

Rated supply voltage 24 VDC

Operating voltage range −15% to 10% of rated supply voltage

Rated power consumption (See note.) 5 W max.

Item Model G9SX-GS226-T15-@

Safety inputs

Operating voltage: 20.4 VDC to 26.4 VDC, Internal impedance: Approx. 2.8 kΩ (See note.)Mode selector input

Feedback/reset input

Item Model G9SX-GS226-T15-@

Instantaneous safety outputs(See note 1.)OFF-delayed safety outputs(See note 1.)

P channel MOS FET transistor outputsLoad current: 0.8 A DC max. (See note 2 and 3.)

Auxiliary outputs(for input, output, and error monitoring)

PNP transistor outputsLoad current: 100 mA max.

External indicator outputs

P channel MOS FET transistor outputsConnectable indicators• Incandescent lamp: 24 VDC, 3 to 7 W• LED lamp: 10 to 300 mA DC

ON

OFF

360 µs max.

Approx.100 ms

Page 75: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. Ratings

G9SXUSER'S GUIDE 75

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

1-4 Expansion UnitPower Input

Note: Power consumption of loads not included.

Outputs

Item Model G9SX-EX-@

Rated supply voltage 24 VDC

Operating voltage range −15% to 10% of rated supply voltage

Rated power consumption (See note.) 2 W max.

Item Model G9SX-EX-@

Rated load 250 VAC, 3 A / 30 VDC, 3 A (resistive load)

Rated carry current 3 A

Maximum switching voltage 250 VAC, 125 VDC

Page 76: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

76G9SX USER'S GUIDE

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

2. Characteristics

2-1 Advanced Unit/Basic Unit

Note: 1. When two or more Units are connected by logical AND, the operating time and response time are the sum total of the operating times and responsetimes, respectively, of all the Units connected by logical AND.

2. Represents the operating time when the safety input turns ON with all other conditions set.3. Represents the operating time when the logical AND input turns ON with all other conditions set.4. For the G9SX-@-RT (with screw terminals) only.

Item Model G9SX-AD322-@/ADA222-@ G9SX-BC202-@

Over-voltage category (IEC/EN 60664-1) II

Operating time (OFF to ON state)(See note 1.)

50 ms max. (Safety input: ON) (See note 2.)100 ms max. (Logical AND connection input: ON) (See note 3.)

50 ms max. (Safety input: ON)

Response time (ON to OFF state)(See note 1.)

15 ms max.

ON-state residual voltage 3.0 V max. (safety output, auxiliary output)

OFF-state leakage current 0.1 mA max. (safety output, auxiliary output)

Maximum wiring length of safety input and logical AND input

100 m max.(External connection impedance: 100 Ω max. and 10 nF max.)

Reset input time (Reset button pressing time)

100 ms min.

Accuracy of OFF-delay time Within ± 5% of the set value ---

Insulation resistance

Between logical AND connection terminals, and power supply input terminals and other input and output terminals connected together

20 MΩ min. (at 100 VDC)

---

Between all terminals connected together and DIN rail

20 MΩ min. (at 100 VDC)

Dielectric strength

Between logical AND connection terminals, and power supply input terminals and other input and output terminals connected together

500 VAC for 1 min

---

Between all terminals connected together and DIN rail

500 VAC for 1 min

Vibration resistance Frequency: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)

Shock resistance

Destruction 300 m/s2

Malfunction 100 m/s2

Ambient temperature −10 to 55°C (no icing or condensation)

Ambient humidity 25% to 85%

Terminal tightening torque (See note 4.) 0.5 N·m

Weight Approx. 200 g Approx. 125 g

Page 77: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Characteristics

G9SXUSER'S GUIDE 77

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

2-2 Non-contact Door Switch Controller

Note: 1. When two or more Units are connected by logical AND, the operating time and response time are the sum total of the operating times and responsetimes, respectively, of all the Units connected by logical AND.

2. Represents the operating time when the safety input turns ON with all other conditions set.3. Represents the operating time when the logical AND input and the Non-contact Door Switch input turn ON with all other conditions set.4. The fault detection time for 24-V short-circuit faults on the non-contact door switch input is 35 ms max.

When calculating the safe distance for applications other than as door switches, use a fault detection time of 35 ms. 5. For the G9SX-@-RT (with screw terminals) only.

Item Model G9SX-NS202-@ G9SX-NSA222-T03-@

Over-voltage category (IEC/EN 60664-1)

II

Operating time (OFF to ON state)(See note 1.)

100 ms max. (Logical AND connection input ON and Non-contact Door Switch input ON)

50 ms max. (Safety input: ON)(See note 2.)100 ms max. (Logical AND connection input ON and Non-contact Door Switch input ON) (See note 3.)

Response time (ON to OFF state)(See note 1.)

15 ms max. (Logical AND connection input: OFF)20 ms max. (Non-contact Door Switch input OFF) (See note 4.)

15 ms max. (Safety input OFF and logical AND connection input OFF)20 ms max. (Non-contact Door Switch input: OFF) (See note 4.)

ON-state residual voltage 3.0 V max. (safety output, auxiliary output)

OFF-state leakage current 0.1 mA max. (safety output, auxiliary output)

Maximum wiring length of safety input, logical AND connection input, and Non-contact Door Switch input

100 m max. (External connection impedance: 100 Ω max. and 10 nF max.)

Reset input time (Reset button pressing time)

100 ms min.

Accuracy of OFF-delay time --- Within ±5% of the set value

Insulationresistance

Between logical AND connection terminals, and power supply input terminals and other input and output terminals connected together

20 MΩ min. (at 100 VDC)

Between all terminals connectedtogether and DIN rail

Dielectricstrength

Between logical AND connection terminals, and power supply input terminals and other input and output terminals connected together

500 VAC for 1 min.

Between all terminals connected together and DIN rail

Vibration resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)

Shock resistance

Destruction 300 m/s2

Malfunction 100 m/s2

Ambient operating temperature −10 to 55°C (no icing or condensation)

Ambient operating humidity 25% to 85%

Terminal tightening torque (See note 5.) 0.5 N·m

Weight Approx. 125 g Approx. 200 g

Page 78: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

2. Characteristics

78G9SX USER'S GUIDE

2-3 Safety Guard Switching Unit

Note: 1. When two or more Units are connected by logical AND, the operating time and response time are the sum total of the operating times and responsetimes, respectively, of all the Units connected by logical AND.

2. Represents the operating time when the safety input turns ON with all other conditions set.3. Represents the operating time when the logical AND input turns ON with all other conditions set.4. This is the allowable switching time for the operating mode selector. If switching takes more than 450 ms, the G9SX-GS@ will detect an error.5. This is the time required for the safety input to actually switch to an activated condition after the mode selector input is switched.

6. Only when the G9SX-GS@ is used with manual switching.7. For the G9SX-@-RT (with screw terminals) only.

Item Model G9SX-GS226-T15-@

Overvoltage category (IEC/EN 60664-1) II

Operating time (OFF to ON state)(See note 1.)

50 ms max. (Safety input: ON) (See note 2.)100 ms max. (Logical AND connection input: ON) (See note 3.)

Response time (ON to OFF state)(See note 1.)

15 ms max.

Allowable switching time for mode selector input (See notes 4 and 6.)

450 ms max.

Response time for switching operating modes (See notes 5 and 6.)

50 ms max.

ON-state residual voltage 3.0 V max. for safety outputs, auxiliary outputs, and external indicator outputs

OFF-state leakage current 0.1 mA max. for safety outputs and auxiliary outputs, 1 mA max. for external indicator outputs

Maximum wiring length of safety input and logical AND input

100 m max.(External connection impedance: 100 Ω max. and 10 nF max.)

Reset input time(Reset button pressing time)

100 ms min.

Accuracy of OFF-delay time Within ± 5% of the set value

Insulation resistance

Between logical AND connection terminals, and power supply input terminals and other input and output terminals connected together 20 MΩ min. (at 100 VDC)

Between all terminals connected together and DIN rail

Dielectric strength

Between logical AND connection terminals, and power supply input terminals and other input and output terminals connected together 500 VAC for 1 min

Between all terminals connected together and DIN rail

Vibration resistance Frequency: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)

Shock resistance

Destruction 300 m/s2

Malfunction 100 m/s2

Ambient operating temperature −10 to 55°C (with no icing or condensation)

Ambient operating humidity 25% to 85%

Terminal tightening torque (See note 7.) 0.5 N·m

Weight Approx. 240 g

M1

M2

UA

UB

450 ms max.

50 ms max.

Safety input A is activated

Safety input B is activated

M1

M2

UA

UB

450 ms max.

50 ms max.

Safety input A is activated

Safety input B is activated

<When M2 Is Turned ON after M1 Is Turned OFF> <When M1 Is Turned OFF after M2 Is Turned ON>

Page 79: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

2. Characteristics

G9SXUSER'S GUIDE 79

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

2-4 Expansion Unit

Note: 1. When two or more Units are connected by logical AND, the operating time and response time are the sum total of the operating times and responsetimes, respectively, of all the Units connected by logical AND.

2. This does not include the operating time or response time of Safety Guard Switching Units (G9SX-AD/-ADA/-NSA/-GS) that are connected.3. This does not include the operating time or response time of internal relays in the [email protected]. For the G9SX-@-RT (with screw terminals) only.

Item Model G9SX-EX-@

Overvoltage category (IEC/EN 60664-1) II (Safety relay outputs 13 to 43 and 14 to 44: III)

Operating time (OFF to ON state)(See note 1.)

30 ms max. (See note 2.)

Response time (ON to OFF state)(See note 1.)

10 ms max. (See note 2.)

ON-state residual voltage 3.0 V max. for safety outputs and auxiliary outputs

OFF-state leakage current 0.1 mA max. for safety outputs and auxiliary outputs

Maximum wiring length of safety input and logical AND input

100 m max.(External connection impedance: 100 Ω max. and 10 nF max.)

Reset input time (Reset button pressing time)

100 ms min.

Accuracy of OFF-delay time (See note 3.) Within ± 5% of the set value

Insulation resistance

Between all terminals connected together and DIN rail

100 MΩ min. (at 500 VDC)

Dielectric strength

Between all terminals connected together and DIN rail 1,200 VAC for 1 min

Between different poles of outputs

Between safety relay outputs connected together and other terminals connected together

2,200 VAC for 1 min

Vibration resistance Frequency: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)

Shock resistance

Destruction 300 m/s2

Malfunction 100 m/s2

DurabilityElectrical

100,000 cycles min. (rated load, switching frequency: 1,800 cycles/hour)

Mechanical 5,000,000 cycles min. (switching frequency: 7,200 cycles/hour)

Ambient operating temperature −10 to 55°C (with no icing or condensation)

Ambient operating humidity 25% to 85%

Terminal tightening torque (See note 4.) 0.5 N·m

Weight Approx. 165 g

Page 80: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

80G9SX USER'S GUIDE

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

3. Dimensions and Terminal arrangementsNote: All units are in millimeters unless otherwise indicated.

3-1 Advanced UnitG9SX-AD322-@

G9SX-ADA222-@

3-2 Basic UnitG9SX-BC202-@

No.OFF-DELAY

0.50.4

0.30.2 15

10754

321.510.6

0.7

0

S54S44S34S24S14 L1A2T42T41T22T21

A1X2X1Y1T12T11T33T31

T1

ERR

EI

AND

FB

ED

T2

PWR

T32

G9SX-AD322-T1524VDC

100 max.

* Typical dimension

(10) 115 max.35.5 max.(35)*

(6) (See note 2.)

(6) (See note 2.)

FBPWR

T1

AND

EI

T2

ED

ERR

S44

T41

S14

T21

S24

T22

S34 S54

T42

L1

A2

T33T32T31

X1Y1T12T11 X2 A1

Note: 1. Above outline drawing is for -RC terminal type.2. For -RC terminal type only.

Terminal arrangement

No.OFF-DELAY

0.50.4

0.30.2 15

10754

321.510.6

0.7

0

L1S54S44S24S14 L2A2T42T41T22T21

A1X2X1Y1T12T11T33T31

T1

ERR

EI

AND1

FB

ED

T2

PWR

T32 T52T51

G9SX-ADA222-T15024VDC

AND2

(6) (See note 2.)

100 max.

(6) (See note 2.)115 max.(10)

* Typical dimension

35.5 max.(35)*

AND1 AND2

G9

SX

-AD

A2

22

-T1

50 FBPWR

T1

AND1

EI

T2

AND2

ED

ERR

S54

T41

S14

T21

S24

T22

S44 L1

T42

L2

A2

T33T32T31

X1Y1T12T11 X2 A1

T51 T52

Note: 1. Above outline drawing is for -RC terminal type.2. For -RC terminal type only.

Terminal arrangement

No.

T1 T2

FB

ERREI

PWR

L2L1S24S14A2X2T22T21

A1X1T12T11Y1T32 T33T31

G9SX-BC20224VDC

* Typical dimension

23 max.(22.5)*

115 max. (6) (See note 2.)

100 max.

(6) (See note 2.)

FBPWR

T1

EI

T2

ERR

L2

A2

S14

T21

S24

T22

L1

X2

Y1T33T32T31

A1X1T12T11

Note: 1. Above outline drawing is for -RC terminal type.2. For -RC terminal type only.

Terminal arrangement

Page 81: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

3. Dimensions and Terminal arrangements

G9SXUSER'S GUIDE 81

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

3-3 Non-contact Door Switch ControllerG9SX-NS202-@

G9SX-NSA222-T03-@

3-4 Safety Guard Switching UnitG9SX-GS226-T15-@

No.

NS

FB

ERR

AND

EI

PWR

D4L1S24S14A2X2T42T41

A1X1D2D1D3T32 T33T31

G9SX-NS20224VDC

* Typical dimension

23 max.(22.5)* 115 max. (6) (See note 2.)

100 max.

(6) (See note 2.)

FBPWR

AND

EI

NS

ERR

D4

A2

S14

T41

S24

T42

L1

X2

D3T33T32T31

A1X1D2D1

Note: 1. Above outline drawing is for -RC terminal type.2. For -RC terminal type only.

Terminal arrangement

No.OFF-DELAY

L1S54S44S24S14 D4A2T42T41T22T21

A1X2X1Y1T12T11T33T31

T1

ERR

EI

AND

FB

ED

T2

PWR

T32 D2 D3D1

G9SX-NSA222-T3024VDC

NS

0.50.4

0.30.2 3.0

2.52.01.8

1.41.21.00.90.8

0.60.7

0

35.5 max.(35)*

* Typical dimension

(10) 115 max. (6) (See note 2.)

100 max.

(6) (See note 2.)

FBPWR

T1

AND

EI

T2

NS

ED

ERR

S54

T41

S14

T21

S24

T22

S44 L1

T42

D4

A2

T33T32T31

X1Y1T12T11 X2 A1

D1 D2 D3

Terminal arrangement

Note: 1. Above outline drawing is for -RC terminal type.2. For -RC terminal type only.

T31 T32 T33T11

Y1 M1 M2T12 T61 T62 Y2 Y3

T21 T22X1 X2 X3 X4 S14 S24

T72T71 T41 T42

24VDC

T1

ERR

G9SX-GS226-T15

EI

T6

FB

ED

UA

PWR

OFF-DELAY

UB

0.2 00.3

0.40.5

0.60.7 1 1.5 2 3

457

1015

T2

T7

AND

UA UBY4 A1

S44 S54L1 A2

No.

* Typical dimension

45.5 max.(45)* (10) 115 max. (6) (See note 2.)

100 max.

(6) (See note 2.)

FB

UA

ED

UB

ERR

PWR

T1

EI

T6

AND

T2

T7

X4

T72

X1

T21

X2

T22 T71

X3 S14

T41

S24

T42

S44

L1

S54

A2

T33T32T31

T62T61T12T11 Y2 Y3 Y4 A1

Y1 M1 M2 UA UB

Note: 1. Above outline drawing is for -RC terminal type.2. For -RC terminal type only.

Terminal arrangement

Page 82: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ratin

gs an

d S

pecificatio

ns

Sectio

n 4

3. Dimensions and Terminal arrangements

82G9SX USER'S GUIDE

3-5 Expansion UnitExpansion UnitG9SX-EX401-@Expansion Unit (OFF-delayed Model)G9SX-EX041-T-@

G9SX-EX041-T

23 max.(22.5)*

* Typical dimension

115 max. (6) (See note 2.)

100 max.

(6) (See note 2.)

43332313

PWR

44

A2

14 24

A1

34

X2

EI

ERR

43332313

PWR

44

A2

14 24

A1

34

X2

ED

ERR

G9SX-EX041-T-@(Expansion Unit with OFF Delay)

G9SX-EX401-@(Expansion Unit)

Note: 1. Above outline drawing is for -RC terminal type.2. For -RC terminal type only.

Terminal arrangement

Page 83: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 83

Ap

pen

dix

Appendix

1. Troubleshooting 84

2. Logical AND Connections 91

3. Accessories and Related Products 93

Page 84: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

84G9SX USER'S GUIDE

Ap

pen

dix

1. Troubleshooting

■ Fault DetectionWhen the G9SX detects a fault, the ERR indicator and/or other indicators light up or blink to inform the user about

the fault.

Check and take necessary measures referring to the following table, and then re-supply power to the G9SX.

■ Error IndicationsG9SX-BC202-@/G9SX-AD322-@/G9SX-ADA222-@

ERR indicator

Other indicator

Fault Expected causes of the fault Check points and measures to take Page

Blinks---

Fault due to electro-magnetic disturbance or of internal circuits

(1) Affected by excessive electromagnetic disturbance.

(1) Check the disturbance level around the G9SX and the related system.

---

(2) Failure of the G9SX internal circuit. (2) Replace the G9SX. ---

Lights

T1 blinks

Fault involved with safety input 1

(1) Incorrect wiring of safety input 1.(For example, cross fault detection mode settings and safety input wiring do not match).

(1) Check the wiring to T11, T12, T21, T22 and Y1.

63

(2) Wiring to safety input 1 and 24 V or another I/O terminal short circuited.

(2) Check the wiring to T11 and T12. ---

(3) Short circuit between safety inputs(when cross fault detection mode is ON).

(3) Check the wiring to T11, T12, T21 and T22.

63

(4) Failure in internal circuit for T11 and T12. (4) Replace the G9SX. ---

T2 blinks

Fault involved with safety input 2

(1) Incorrect wiring of safety input 2.(For example, cross fault detection mode settings and safety input wiring do not match).

(1) Check the wiring to T11, T12, T21, T22 and Y1.

63

(2) Wiring to safety input 2 and 24 V or another I/O terminal short circuited.

(2) Check the wiring to T21 and T22. ---

(3) Short circuit between safety inputs(when cross fault detection mode is ON).

(3) Check the wiring to T11, T12, T21 and T22.

63

(4) Failure in internal circuit for T21 and T22. (4) Replace the G9SX. ---

FB blinks

Fault involved with feedback/reset inputs

(1) Incorrect feedback/reset input wiring. (1) Check the wiring to T31, T32 and T33. 62

Fault in Expansion Unit

(2) Connecting cable to Expansion Unit or terminating connector disconnected.

(2) Check the connecting cable to the Expansion Unit and the connection of the terminating connector.

69

Abnormal supply voltage to Expansion Unit

(3) Voltage fluctuation caused by insufficient supply voltage current capacity.

(3) Change to a power supply with a greater current capacity.

---

(4) Supply voltage outside the rated value.(4) Connect to a supply voltage of 24 VDC

-15% to +10%.---

Failure in internal circuit

(5) Failure in internal circuit for T31, T32 and T33.

(5) Replace the G9SX. ---

(6) Expansion Unit relay contact or internal circuit failed.

(6) Replace the Expansion Unit. ---

EI blinks

Fault involved with instantaneous safety outputs

(1) Instantaneous safety outputs short circuited.

(1) Check the wiring to S14, S24 and S34. ---

(2) Instantaneous safety outputs and 24 V, 0 V, or another I/O terminal short circuited.

(2) Check the wiring to S14, S24 and S34. ---

Fault involved with logical AND connection outputs

(3) Logical AND connection outputs and 24 V, 0 V, or another I/O terminal short circuited.

(3) Check the wiring to L1 and L2. ---

Abnormal ambient temperature

(4) The environment exceeds the permissible ambient operating temperature.

(4) Check the ambient temperature and spacing around the G9SX.

76

Failure in internal circuit

(5) Failure in internal circuit for S14, S24 and S34.

(5) Replace the G9SX. ---

(6) Failure in internal circuit for L1 and L2. (6) Replace the G9SX. ---

Page 85: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. Troubleshooting

G9SXUSER'S GUIDE 85

Ap

pen

dix

When indicators other than the ERR indicator blink, check and take necessary actions referring to the following table.

ERR indicator

Other indicator

Fault Expected causes of the fault Check points and measures to take Page

Lights

ED blinks

Fault involved with OFF-delayed safety outputs

(1) Safety OFF-delayed outputs short circuited.

(1) Check the wiring to S44 and S54. ---

(2) Wiring to the OFF-delayed safety contact outputs and 24 V, 0 V, or another I/O terminal short circuited.

(2) Check the wiring to S44 and S54. ---

Incorrect set values for OFF-delay time

(3) Settings of two OFF-delay time preset switches are not the same.

(3) Confirm the set values of the OFF-delay time preset switches on the front and back of the Unit.

65

Abnormal ambient temperature

(4) The environment exceeds the permissible ambient operating temperature.

(4) Check the ambient temperature and spacing around the G9SX.

76

Failure in internal circuit

(5) Failure in internal circuit for S44 and S54.

(5) Replace the G9SX. ---

(6) OFF-delay time preset switch failed. (6) Replace the G9SX. ---

AND blinks (AND1, AND2)

Fault involved with logical AND connection input

(1) Logical AND connection input and 24 V, 0 V, or another I/O terminal short circuited.

(1) Check the wiring to T41 and T51. ---

(2) Maximum cable length exceeded.(2) Make sure that the wiring length for the

T41, T42, T51 and T52 terminals is less than 100 m.

---

(3) Maximum number of connected Units exceeded.

(3) Check the logical AND connection for the G9SX.

59

Incorrect setting for logical AND connection setting switch

(4) The logical AND connection preset switch is set to OFF.

(4) When using a logical AND connection, set the logical AND connection preset switch to AND.

57

Fault in internal circuit

(5) Failure in internal circuit for T41, T42, T51 and T52.

(5) Replace the G9SX. ---

(6) The logical AND connection preset switch failed.

(6) Replace the G9SX. ---

All indicators except PWR

blink

Supply voltage outside the rated value

(1) Supply voltage outside the rated value.(1) Connect to a supply voltage of 24 VDC

-15% to +10%.---

(2) Voltage fluctuation caused by insufficient supply voltage current capacity.

(2) Change to a power supply with a greater current capacity.

---

ERR indicator

Other indicator

Fault Expected causes of the fault Check points and measures to take Page

Off

T1

Blinks

Mismatch between input 1 and input 2

The input status between safety input 1 and safety input 2 is different due to a contact failure or short circuit of a safety input device or a wiring fault.

Check the wiring from safety input devices to the G9SX. Or check the input sequence of safety input devices.After removing the fault, turn both safety input 1 and 2 to the OFF state.

---

T2

Page 86: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

pen

dix

1. Troubleshooting

86G9SX USER'S GUIDE

G9SX-NS202-@/G9SX-NSA222-@ERR

indicatorOther

indicatorFault Expected causes of the fault Check points and measures to take Page

Blinks---

Fault due to electro-magnetic disturbance or of internal circuits

(1) Affected by excessive electromagnetic disturbance.

(1) Check the disturbance level around the G9SX and the related system.

---

(2) Failure of the G9SX internal circuit. (2) Replace the G9SX. ---

Lights

T1 blinks

Fault involved with safety input 1

(1) Incorrect wiring of safety input 1.(For example, cross fault detection mode settings and safety input wiring do not match).

(1) Check the wiring to T11, T12, T21, T22 and Y1.

63

(2) Wiring to safety input 1 and 24 V or another I/O terminal short circuited.

(2) Check the wiring to T11 and T12. ---

(3) Short circuit between safety inputs(when cross fault detection mode is ON).

(3) Check the wiring to T11, T12, T21 and T22.

63

(4) Failure in internal circuit for T11 and T12. (4) Replace the G9SX. ---

T2 blinks

Fault involved with safety input 2

(1) Incorrect wiring of safety input 2.(For example, cross fault detection mode settings and safety input wiring do not match).

(1) Check the wiring to T11, T12, T21, T22 and Y1.

63

(2) Wiring to safety input 2 and 24 V or another I/O terminal short circuited.

(2) Check the wiring to T21 and T22. ---

(3) Short circuit between safety inputs(when cross fault detection mode is ON).

(3) Check the wiring to T11, T12, T21 and T22.

63

(4) Failure in internal circuit for T21 and T22. (4) Replace the G9SX. ---

NS blinks

Fault in Non-contact Door Switch input

(1) Wiring to the Non-contact Door Switch input and 24 V or another I/O terminal short circuited.

(1) Check the wiring to D1 and D2. 66

(2) Incorrect wiring of Non-contact Door Switch inputs in series connection.

(2) Check the wiring to the D40A. 66

Failure in internal circuit

(3) Non-contact Door Switch failed. (3) Replace the D40A. ---

(4) Failure in internal circuit for D1 and D2. (4) Replace the G9SX. ---

FB blinks

Fault involved with feedback/reset inputs

(1) Incorrect feedback/reset input wiring. (1) Check the wiring to T31, T32, and T33. 62

Fault in Expansion Unit

(2) Connecting cable to Expansion Unit or terminating connector disconnected.

(2) Check the connecting cable to the Expansion Unit and the connection of the terminating connector.

69

Abnormal supply voltage to Expansion Unit

(3) Voltage fluctuation caused by insufficient supply voltage current capacity.

(3) Change to a power supply with a greater current capacity.

---

(4) Supply voltage outside the rated value.(4) Connect to a supply voltage of 24 VDC

-15% to +10%.---

Failure in internal circuit

(5) Failure in internal circuit for T31, T32 and T33.

(5) Replace the G9SX. ---

(6) Expansion Unit relay contact or internal circuit failed.

(6) Replace the Expansion Unit. ---

EI blinks

Fault involved with instantaneous safety outputs

(1) Instantaneous safety outputs short circuited.

(1) Check the wiring to S14 and S24. ---

(2) Instantaneous safety outputs and 24 V, 0 V, or another I/O terminal short circuited.

(2) Check the wiring to S14 and S24. ---

Fault involved with logical AND connection outputs

(3) Logical AND connection outputs and 24 V, 0 V, or another I/O terminal short circuited.

(3) Check the wiring to L1. ---

Abnormal ambient temperature

(4) The environment exceeds the permissible ambient operating temperature.

(4) Check the ambient temperature and spacing around the G9SX.

77

Failure in internal circuit

(5) Failure in internal circuit for S14 and S24.

(5) Replace the G9SX. ---

(6) Failure in internal circuit for L1. (6) Replace the G9SX. ---

Page 87: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. Troubleshooting

G9SXUSER'S GUIDE 87

Ap

pen

dix

When indicators other than the ERR indicator blink, check and take necessary actions referring to the following table.

ERR indicator

Other indicator

Fault Expected causes of the fault Check points and measures to take Page

Lights

ED blinks

Fault involved with OFF-delayed safety outputs

(1) Safety OFF-delayed outputs short circuited.

(1) Check the wiring to S44 and S54. ---

(2) Wiring to the OFF-delayed safety contact outputs and 24 V, 0 V, or another I/O terminal short circuited.

(2) Check the wiring to S44 and S54. ---

Incorrect set values for OFF-delay time

(3) Settings of two OFF-delay time preset switches are not the same.

(3) Confirm the set values of the OFF-delay time preset switches on the front and back of the Unit.

65

Abnormal ambient temperature

(4) The environment exceeds the permissible ambient operating temperature.

(4) Check the ambient temperature and spacing around the G9SX.

77

Failure in internal circuit

(5) Failure in internal circuit for S44 and S54.

(5) Replace the G9SX. ---

(6) OFF-delay time preset switch failed. (6) Replace the G9SX. ---

AND blinks

Fault involved with logical AND connection input

(1) Logical AND connection input and 24 V, 0 V, or another I/O terminal short circuited.

(1) Check the wiring to T41. ---

(2) Maximum cable length exceeded.(2) Make sure that the wiring length for the

T41 and T42 terminals is less than 100 m.---

(3) Maximum number of connected Units exceeded.

(3) Check the logical AND connection for the G9SX.

59

Incorrect setting for logical AND connection setting switch

(4) The logical AND connection preset switch is set to OFF.

(4) When using a logical AND connection, set the logical AND connection preset switch to AND.

57

Fault in internal circuit

(5) Failure in internal circuit for T41 and T42.

(5) Replace the G9SX. ---

(6) The logical AND connection preset switch failed.

(6) Replace the G9SX. ---

All indicators except PWR

blink

Supply voltage outside the rated value

(1) Supply voltage outside the rated value.(1) Connect to a supply voltage of 24 VDC

-15% to +10%.---

(2) Voltage fluctuation caused by insufficient supply voltage current capacity.

(2) Change to a power supply with a greater current capacity.

---

ERR indicator

Other indicator

Fault Expected causes of the fault Check points and measures to take Page

Off

T1

Blinks

Mismatch between input 1 and input 2

The input status between safety input 1 and safety input 2 is different due to a contact failure or short circuit of a safety input device or a wiring fault.

Check the wiring from safety input devices to the G9SX. Or check the input sequence of safety input devices.After removing the fault, turn both safety input 1 and 2 to the OFF state.

---

T2

Page 88: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

pen

dix

1. Troubleshooting

88G9SX USER'S GUIDE

G9SX-GS226-@ERR

indicatorOther

indicatorFault Expected causes of the fault Check points and measures to take Page

Blinks---

Fault due to electro-magnetic disturbance or of internal circuits

(1) Affected by excessive electromagnetic disturbance.

(1) Check the disturbance level around the G9SX and the related system.

---

(2) Failure of the G9SX internal circuit. (2) Replace the G9SX. ---

Lights

T1 blinks

Fault involved with safety input A, channel 1

(1) Incorrect wiring of safety input A channel 1. (For example, cross fault detection mode settings and safety input wiring do not match.)

(1) Check the wiring to T11, T12, T21, T22 and Y1.

63

(2) Wiring to safety input A channel 1 and 24 V or another I/O terminal short circuited.

(2) Check the wiring to T11 and T12. ---

(3) Short circuit between safety inputs(when cross fault detection mode is ON).

(3) Check the wiring to T11, T12, T21 and T22.

63

(4) Failure in internal circuit for T11 and T12. (4) Replace the G9SX. ---

T2 blinks

Fault involved with safety input A, channel 2

(1) Incorrect wiring of safety input A channel 2. (For example, cross fault detection mode settings and safety input wiring do not match.)

(1) Check the wiring to T11, T12, T21, T22 and Y1.

63

(2) Wiring to safety input A channel 2 and 24 V or another I/O terminal short circuited.

(2) Check the wiring to T21 and T22. ---

(3) Short circuit between safety inputs(when cross fault detection mode is ON).

(3) Check the wiring to T11, T12, T21 and T22.

63

(4) Failure in internal circuit for T21 and T22. (4) Replace the G9SX. ---

T6 blinks

Fault involved with safety input B, channel 1

(1) Incorrect wiring of safety input B channel 1. (For example, cross fault detection mode settings and safety input wiring do not match.)

(1) Check the wiring to T61, T62, T71, T72 and Y2.

63

(2) Wiring to safety input B channel 1 and 24 V or another I/O terminal short circuited.

(2) Check the wiring to T61 and T62. ---

(3) Short circuit between safety inputs(when cross fault detection mode is ON).

(3) Check the wiring to T61, T62, T71 and T72.

63

(4) Failure in internal circuit for T61 and T62. (4) Replace the G9SX. ---

T7 blinks

Fault involved with safety input B, channel 1

(1) Incorrect wiring of safety input B channel 2. (For example, cross fault detection mode settings and safety input wiring do not match.)

(1) Check the wiring to T61, T62, T71, T72 and Y2.

63

(2) Wiring to safety input B channel 2 and 24 V or another I/O terminal short circuited.

(2) Check the wiring to T71 and T72. ---

(3) Short circuit between safety inputs(when cross fault detection mode is ON).

(3) Check the wiring to T61, T16, T71 and T72.

63

(4) Failure in internal circuit for T71 and T72. (4) Replace the G9SX. ---

FB blinks

Fault involved with feedback/reset inputs

(1) Incorrect feedback/reset input wiring. (1) Check the wiring to T31, T32, and T33. 62

Fault in Expansion Unit

(2) Connecting cable to Expansion Unit or terminating connector disconnected.

(2) Check the connecting cable to the Expansion Unit and the connection of the terminating connector.

69

Abnormal supply voltage to Expansion Unit

(3) Voltage fluctuation caused by insufficient supply voltage current capacity.

(3) Change to a power supply with a greater current capacity.

---

(4) Supply voltage outside the rated value.(4) Connect to a supply voltage of 24 VDC

-15% to +10%.---

Failure in internal circuit

(5) Failure in internal circuit for T31, T32 and T33.

(5) Replace the G9SX. ---

(6) Expansion Unit relay contact or internal circuit failed.

(6) Replace the Expansion Unit. ---

Page 89: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

1. Troubleshooting

G9SXUSER'S GUIDE 89

Ap

pen

dix

ERR indicator

Other indicator

Fault Expected causes of the fault Check points and measures to take Page

Lights

EI blinks

Fault involved with instantaneous safety outputs

(1) Instantaneous safety outputs short circuited.

(1) Check the wiring to S14 and S24. ---

(2) Instantaneous safety outputs and 24 V, 0 V, or another I/O terminal short circuited.

(2) Check the wiring to S14 and S24. ---

Fault involved with logical AND connection outputs

(3) Logical AND connection outputs and 24 V, 0 V, or another I/O terminal short circuited.

(3) Check the wiring to L1. ---

Abnormal ambient temperature

(4) The environment exceeds the permissible ambient operating temperature.

(4) Check the ambient temperature and spacing around the G9SX.

78

Failure in internal circuit

(5) Failure in internal circuit for S14 and S24.

(5) Replace the G9SX. ---

(6) Failure in internal circuit for L1. (6) Replace the G9SX. ---

ED blinks

Fault involved with OFF-delayed safety outputs

(1) Safety OFF-delayed outputs short circuited.

(1) Check the wiring to S44 and S54. ---

(2) Wiring to the OFF-delayed safety contact outputs and 24 V, 0 V, or another I/O terminal short circuited.

(2) Check the wiring to S44 and S54. ---

Incorrect set values for OFF-delay time

(3) Settings of two OFF-delay time preset switches are not the same.

(3) Confirm the set values of the OFF-delay time preset switches on the front and back of the Unit.

65

Abnormal ambient temperature

(4) The environment exceeds the permissible ambient operating temperature.

(4) Check the ambient temperature and spacing around the G9SX.

78

Failure in internal circuit

(5) Failure in internal circuit for S44 and S54.

(5) Replace the G9SX. ---

(6) OFF-delay time preset switch failed. (6) Replace the G9SX. ---

AND blinks

Fault involved with logical AND connection input

(1) Logical AND connection input and 24 V, 0 V, or another I/O terminal short circuited.

(1) Check the wiring to T41. ---

(2) Maximum cable length exceeded.(2) Make sure that the wiring length for the

T41 and T42 terminals is less than 100 m.---

(3) Maximum number of connected Units exceeded.

(3) Check the logical AND connection for the G9SX.

59

Incorrect setting for logical AND connection setting switch

(4) The logical AND connection preset switch is set to OFF.

(4) When using a logical AND connection, set the logical AND connection preset switch to AND.

57

Fault in internal circuit

(5) Failure in internal circuit for T41 and T42.

(5) Replace the G9SX. ---

(6) The logical AND connection preset switch failed.

(6) Replace the G9SX. ---

UA blinks

Fault in external indicator output

(1) Wiring to the external indicator output and 24 V, 0 V, or another I/O terminal short circuited.

(1) Check the wiring to UA. ---

(2) External indicator output disconnected.(external indicator not connected)

(2) Check the wiring to UA. 68

Failure of the external indicator

(3) External indicator failed.(3) Replace the connected external

indicator.---

Fault in the external indicator diagnosis switching input

(4) Wiring for external indicator diagnosis switching input and 24 V disconnected.(when external indicator was not connected)

(4) Check the wiring to Y3. 68

Failure in internal circuit

(5) Failure in internal circuit for UA. (5) Replace the G9SX. ---

(6) Failure in internal circuit for Y3. (6) Replace the G9SX. ---

Page 90: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

pen

dix

1. Troubleshooting

90G9SX USER'S GUIDE

When indicators other than the ERR indicator blink, check and take necessary actions referring to the following table.

G9SX-EX401-@/G9SX-EX041-T-@

ERR indicator

Other indicator

Fault Expected causes of the fault Check points and measures to take Page

Lights

UB blinks

Fault in external indicator output

(1) Wiring to the external indicator output and 24 V, 0 V, or another I/O terminal short circuited.

(1) Check the wiring to UB. ---

(2) External indicator output disconnected.(external indicator not connected)

(2) Check the wiring to UB. 68

Failure of the external indicator

(3) External indicator failed. (3) Replace the external indicator. ---

Fault in the external indicator diagnosis switching input

(4) Wiring for external indicator diagnosis switching input and 24 V disconnected.(when external indicator was not connected)

(4) Check the wiring to Y4. 68

Failure in internal circuit

(5) Failure in internal circuit for UB. (5) Replace the G9SX. ---

(6) Failure in internal circuit for Y4. (6) Replace the G9SX. ---

UA and UB alternately

blink

Fault involved with the Switching Function

(1) Incorrect setting of the Switching Function setting switch or incorrect wiring to the mode selector input.

(1) Check the wiring to the M1 and M2, and the setting of the Switching Function setting switch.

67

(2) Wiring to the mode selector input and 24 V, 0 V, or another I/O terminal short circuited.

(2) Check the wiring to M1 and M2. 67

Mode selector error

(3) Incorrect mode selector input switching time.

(3) Check the mode selector input switching time.

78

(4) Mode selector failed. (4) Replace mode switch. ---

Failure in internal circuit

(5) Internal circuit of the mode selector input failed.

(5) Replace the G9SX. ---

All indicators except PWR

blink

Supply voltage outside the rated value

(1) Supply voltage outside the rated value.(1) Connect to a supply voltage of 24 VDC

-15% to +10%.---

(2) Voltage fluctuation caused by insufficient supply voltage current capacity.

(2) Change to a power supply with a greater current capacity.

---

ERR indicator

Other indicator

Fault Expected causes of the fault Check points and measures to take Page

Off

T1

Blinks

Safety input A mismatch

The input status between safety input A channel 1 and safety input A channel 2 is different due to contact failure or a short circuit of safety input device or a wiring fault.

Check the wiring from safety input devices to the G9SX-GS@. Or check the input sequence of safety input devices.After removing the fault, turn both safety input A channels 1 and 2 to the OFF state.

---

T2

T6Safety input B mismatch

The input status between safety input B channel 1 and safety input B channel 2 is different due to contact failure or a short circuit of safety input device or a wiring fault.

Check the wiring from safety input devices to the G9SX-GS@. Or check the input sequence of safety input devices.After removing the fault, turn both safety input B channels 1 and 2 to the OFF state.

---

T7

ERR indicator

Other indicator

Fault Expected causes of the fault Check points and measures to take Page

Lights---

Failure of the Expansion Unit

Internal safety relay contact is welded. Replace the G9SX-EX@. ---

Internal circuit failed. Replace the G9SX-EX@. ---

Page 91: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 91

Ap

pen

dix

2. Logical AND ConnectionsThe logical AND connection is used to build logic between multiple safety inputs and safety outputs. This technology

is unique to the G9SX Series.

■ Logical AND Connection SignalsPulse signals are used in the G9SX logical AND connection and dynamic processing is used to monitor the signals.

Information on safety between Units is passed by these pulse signals, which are also used to detect faults in the

connection and short circuits.

For this reason, up to safety category 4 can be achieved without redundant logical AND connection signal lines.

■ InsulationThe logical AND connection input section of the G9SX is insulated. Therefore, even when the G9SX logical AND

connection cable is configured across multiple devices, it is not necessary to use a shared power source.

24 VDC

G9SX G9SX

24 VDC

T41 T42A2

A1

A2 L1

A1

Logical AND connection signal

Internalcircuit

Internalcircuit

Power supply A

Power supply B

Insulationprovided

here.

Device A

Device B

Logical AND connection

Unit A

Unit B

Page 92: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

pen

dix

2. Logical AND Connections

92G9SX USER'S GUIDE

■ Simplifying Safety CircuitsSafety circuits were traditionally built by combining relay contacts, but now the logical AND connections of the G9SX

simplify building safety circuits.

A safety system will be described in which the power is turned ON when safety input 1 and safety input 2 are

simultaneously input.

Previous Circuit with Relay Units

Safety Circuit with G9SX

Motor controller

M

KM1

KM2

(1)

Internalcircuit

Internalcircuit

Safety Input 1 Safety Input 2

Unit 1

Unit 2

FeedbackInput

FeedbackInput

Robot

Motor controller

M

KM1

KM2

Logical ANDconnection

Internalcircuit

Internalcircuit

Safety Input 1

Unit 1

Unit 2

FeedbackInput

Robot

Section (1) in the above figure can be constructed with only 2 wires.

Safety Input 2

Page 93: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

3. Accessories and Related Products

G9SXUSER'S GUIDE 93

Ap

pen

dix

3. Accessories and Related ProductsAccessories: Terminal Blocks

Note: 1. The illustrations show 3-pin models.2. The G9SX comes with the terminal blocks attached. The accessories shown here can be ordered as replacements.

Related Products

Appearance(See note 1.)

Specifications Applicable Units Model Remarks

Terminal Block with screw terminals (3-pin)

G9SX-AD-@-RTG9SX-ADA-@-RTG9SX-NSA-@-RT

Y9S-03T1B-02A

Set including two terminal blocks (black) with screw terminals and six code marks to prevent incorrect insertion.

Terminal Block with screw terminals (4-pin)

G9SX-BC-@-RTG9SX-EX-@-RTG9SX-NS-@-RTG9SX-GS-@-RT

Y9S-04T1B-02A

Set including two terminal blocks (black) with screw terminals and six code marks to prevent incorrect insertion.

Terminal Block with Spring-cage Terminals (3-pin)

G9SX-AD-@-RCG9SX-ADA-@-RCG9SX-NSA-@-RC

Y9S-03C1B-02A

Set including two terminal blocks (black) with spring-cage terminals and six code marks to prevent incorrect insertion.

Terminal Block with Spring-cage Terminals (4-pin)

G9SX-BC-@-RCG9SX-EX-@-RCG9SX-NS-@-RCG9SX-GS-@-RC

Y9S-04C1B-02A

Set including two terminal blocks (black) with spring-cage terminals and six code marks to prevent incorrect insertion.

Name ModelCertified

BodyAppearance Features

Safety Category

Compact Safety Door Switch

D4NS

• Lineup includes models with 3 contacts (DPST-NC + SPST-NO and TPST-NC models) in addition to the previous DPST-NC + SPST-NO and DPST-NC models.

• Models with M12 connectors are available to save labor and simplify replacement work.

• Standard-feature gold-clad contacts provide high contact reliability. Can be used with both standard loads and microloads.

4

Compact Guard Lock Safety Door Switch

D4NL

• Built-in switches with four- or five-terminal contact construction are available.

• Key holding force of 1,300 N minimum.• Can be used for either standard loads or microloads.• Lineup includes models with a conduit size of M20.• IP67 degree of protection.

4

Compact Safety Limit Switch

D4N

• Lineup includes models with 3 contacts (DPST-NC + SPST-NO and TPST-NC models) in addition to the previous DPST-NC + SPST-NO and DPST-NC models.

• Models with M12 connectors are available to save labor and simplify replacement work.

• Standard-feature gold-clad contacts provide high contact reliability. Can be used with both standard loads and microloads.

4

Compact Non-contact Door Switch/ Flexible Safety Unit

D40A/G9SX-NS

• Stable operation reduces Controller errors caused by unstable doors.

• Connect up to 30 Non-contact Door Switches with LED indicators to one Controller.

• Reversible switch provides flexibility in installation.• Two-color LED indicator enables easier

maintenance by providing identification of door status and cable disconnections.

• Both Non-contact Door Switches and conventional Key-type Safety-door Switches can be input to one Controller, saving space.

3(EN954-1)

SIL3(IEC/EN61508)

Page 94: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Ap

pen

dix

3. Accessories and Related Products

94G9SX USER'S GUIDE

Safety Light Curtain

F3SJVer.2

• Conforms to EN and IEC standards and incorporates the highest level of safety design.

• Can be front-mounted, top-mounted, or back-mounted in series.

• Finger, hand, or hand to body protection.• Sensing width of 245 to 2,500 mm.

4

Emergency Stop Switch

A165E

• Same length as the 16-dia. Short-body A3B Switch and allows mounting or dismounting of the Switch Unit.

• Operational Unit design remains the same as previous models.

• Large terminals for easy wiring.• Switch Unit can be easily mounted or dismounted

using a special tool.

4

Emergency Stop Switch

A22E

• Easy mounting or dismounting of the Switch Unit from the Operational Unit using a lever (provided).

• Not only round or forked crimp terminals, but also solid wires can be connected to the Switch.

• Safety lock mechanism provided for the first time for 22-dia. models.

• Applicable to 22.3-dia. or 25-dia. panel cutouts. IP65 degree of protection. (However, also use A22Z-R25 for 25-dia. cutout)

• Employs a three-tier terminal block (for lighted model) for easy wiring in narrow spaces.

4

Enabling Grip Switch

A4EG

Scheduled for release in autumn of 2007.

• Sure click feel to ensure operation. • Easy configuration of safety circuits when combined

with the G9SX-GS.4

Key-type Selector Switch

A22K• For changing modes when using the manual

switching function of the G9SX-GS.• Direct opening mechanism (NC contacts only).

---

Name ModelCertified

BodyAppearance Features

Safety Category

Page 95: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

G9SXUSER'S GUIDE 95

Precau

tion

s

Precautions

Page 96: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

96G9SX USER'S GUIDE

Precau

tion

s

Safety Precautions

!WARNING

<Precautions for All G9SX Models>

<G9SX-GS@>

Serious injury may possibly occur due to breakdown

of safety outputs.

Do not connect loads beyond the rated value to the

safety outputs.

Serious injury may possibly occur due to loss of

required safety functions.

Wire G9SX properly so that supply voltages or

voltages for loads do NOT touch the safety inputs

accidentally or unintentionally.

Serious injury may possibly occur due to damages of

safety inputs.

Apply protection circuitry against back electromotive

force in case connecting inductive loads to safety

outputs.

Serious injury may possibly occur due to loss of

safety functions. Use devices appropriate for the

application and the condition where G9SX is used.

Control Devices Requirements

Emergency Stop Switches

Use approved devices with Direct Opening Mechanism complying with IEC/EN 60947-5-1.Do not connect an Emergency Stop Switch to the G9SX-GS@.

Door interlocking switches or limit switches.

Use approved devices with Direct Opening Mechanism complying with IEC/EN 60947-5-1 and capable of switching micro loads of 24VDC, 5mA.

Safety Sensors

Use approved devices complying with the relevant product standards, regulations and rules in the country where it is used.Consult a certification body to assess that the entire system satisfies the required safety category level.

Relays with forcibly guided contacts

Use approved devices with forcibly guided contacts complying with EN 50205.For feedback purpose use devices with contacts capable of switching micro loads of 24VDC, 5mA.

Contactors

Use contactors with forcibly guided mechanism to input the signal to Feedback/Reset input of G9SX through the NC contact of the contactor.For feedback purpose use devices with contacts capable of switching micro loads of 24VDC, 5mA.Failure to open contacts of a contactor cannot be detected by monitoring its auxiliary NC contact without forcibly guided mechanism.

Other devicesEvaluate whether devices used are appropriate to satisfy the requirements of safety category level.

Serious injury may possibly occur due to loss of

safety functions. Construct an appropriate safety

system as shown in the following table.

Switching function

Auto switching

Safety system configuration example

Safety precautions

(1) Select Safety Sensors that satisfy the following condition:1. Diameter of the smallest detectable object <

Diameter of the object to be detected.(2) Install the Safety Sensors so that they satisfy the

following conditions:1. Use Safety Sensor A to detect the entry of the

machine into area A, and Safety Sensor B to detect the entry of a person into area A.

2. Make sure that the machine can reach area A only by passing through Safety Sensor A, and that a person can reach area A only by passing through Safety Sensor B.

(3) Provide a protective structure to prevent a person from passing completely through Safety Sensor B and stepping into area A. If this is not possible, install a sensor that will detect the presence of a person inside area A and prevent the machine from being restarted while the person is inside area A.

(4) Provide a sufficient safety distance (S1) considering the entry speed of a person and a sufficient safety distance (S2) considering the entry speed of the machine. For details, refer to Safety Distance on page 97.

Switching function

Manual switching

Safety system configuration example

Safety precautions

(1) Select Safety Sensors that satisfy the following condition:1. Diameter of the smallest detectable object <

Diameter of the object to be detected.(2) Install the Safety Sensors so that they satisfy the

following conditions:1. Use the Safety Sensor to detect the entry of the

machine into area A.2. Make sure that the machine can reach area A only

by passing through the Safety Sensor.(3) Provide a protective structure to prevent a person from

stepping into area A when the door is opened. If this is not possible, install a sensor that will detect the presence of a person inside area A and prevent the machine from being restarted while the person is inside area A.

(4) Provide a sufficient safety distance (S2) considering the entry speed of the machine. For details, refer to Safety Distance on page 97.

(5) Position the mode selector in a location where it cannot be operated from inside area A.

Person

Machine

Safety Sensor A

Safety Sensor B

Area A

Machine

Person

Area A Mode selector

Safety Sensor

Safety Door SwitchSafety Limit Switch

Page 97: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Safety Precautions

G9SXUSER'S GUIDE 97

Precau

tion

s

Safety DistanceThe safety distance is the minimum distance that must be provided between the safety input device and a machine's hazardous part to stop the hazardous part before a person or object reaches it. The safety distance varies according to the standards of each country and the specifications of each machine. In addition, the calculation of the safety distance differs if the direction of approach is not perpendicular to the detection zone of the safety input device. Always refer to the relevant standards.

Safety Distance Concepts

Safety Distance Calculation Examples (Reference)

( 1 ) To determine the approach speed K1, consider all factors, including the operator's physical abilities.

( 2 ) To determine the maximum approach speed K2, consult with a notified body or other authoritative institutes.

( 3 ) The response time of a machine is the time from when the machine receives a stop signal to the time when the machine's hazardous part stops. Measure the response time on the actual system. Also, periodically check that the machine's response time has not changed.

( 4 ) For information on the response time of the G9SX system, refer to item 10 of Precautions for Correct Use on page 98.

■ Precautions for Safe Use<Precautions for All G9SX Models>( 1 ) Use G9SX within an enclosure with IP54 protection or

higher of IEC/EN60529.

( 2 ) Incorrect wiring may lead to loss of safety function. Wire conductors correctly and verify the operation of G9SX before commissioning the system in which G9SX is incorporated.

( 3 ) Do not apply DC voltages exceeding the rated voltages, or any AC voltages to the G9SX power supply input.

( 4 ) Use DC supply satisfying requirements below to prevent electric shock.• DC power supply with double or reinforced insulation, for

example, according to IEC/EN60950 or EN50178 or a transformer according to IEC/EN61558.

• DC supply satisfies the requirement for class 2 circuits or limited voltage/current circuit stated in UL 508.

( 5 ) Apply properly specified voltages to G9SX inputs. Applying inappropriate voltages cause G9SX to fail to perform its specified function, which leads to the loss of safety functions or damages to G9SX.

( 6 ) Auxiliary error outputs and auxiliary monitoring outputs are NOT safety outputs. Do not use auxiliary outputs as any safety output.Such incorrect use causes loss of safety function of G9SX and its relevant system. Also Logical AND connection outputs can only be used for logical AND connections between G9SXs.

( 7 ) After installation of G9SX, qualified personnel should confirm the installation, and should conduct test operations and maintenance.The qualified personnel should be qualified and authorized to secure the safety on each phases of design, installation, running, maintenance and disposal of system.

( 8 ) A person in charge, who is familiar to the machine in which G9SX is to be installed, should conduct and verify the installation.

( 9 ) Perform daily and 6-month inspections on the G9SX. Otherwise, the system may fail to work properly, resulting in serious injury.

(10) Do not dismantle, repair, or modify G9SX. It may lead to loss of its safety functions.

(11) Use only appropriate components or devices complying with relevant safety standards corresponding to the required level of safety categories. Conformity to requirements of safety category is determined as an entire system. It is recommended to consult a certification body regarding assessment of conformity to the required safety level.

(12) OMRON shall not be responsible for conformity with any safety standards regarding to customer's entire system.

(13) Disconnect G9SX from power supply when wiring, to prevent electric shock or unexpected operation.Doing so may lead to the loss of its safety functions.

(14) Be cautious not to have your fingers caught when attaching terminal sockets to the plugs on G9SX.

(15) Do not use in combustible gases or explosive gases.

When a person approaches a hazard (machine)

• S1: Safety distance 1• P1: The closest that a machine can come to a person

while operating (the boundary of the machine's operating area)

When a hazard (machine) approaches a person

• S2: Safety distance 2• P2: The closest that a part of a person can come to a

machine.

Calculating the safety distance specified by international standard ISO 13855-2002 (European standard EN 999-1999)

If a person approaches the detection zone perpendicularly, calculate the safety distance as shown below.S1 = K1 × T + CS2 = K2 × T + C

S1: Safety distance 1S2: Safety distance 2K1: Approach speed of a person to the detection

zone (area A)K2: Maximum approach speed of a machine to the

detection zone (area A)T: Total response time of the machine and G9SX

systemC: Additional distance calculated by the detection

capability (the diameter of the smallest detectable object) of the Safety Sensor.

Calculating the safety distance specified by American standard ANSI B11.19

If a person approaches the detection zone perpendicularly, calculate the safety distance as shown below.S1 = K1 × (Ts + Tc + Tr + Tbm) + DpfS2 = K2 × (Ts + Tc + Tr + Tbm) + Dpf

S1: Safety distance 1S2: Safety distance 2K1: Approach speed of a person to the detection

zone (area A)K2: Maximum approach speed of a machine to the

detection zone (area A)Ts: Machine's stop time (s)Tr: Response time of the G9SX system from ON to

OFF (s)Tc: Machine control circuit's maximum response

time required to activate its brake (s)Tbm: Additional time (s)Dpf: Additional distance

Person

Machine

P1

S1

Safety Sensor A

Safety Sensor B

Area A

Person

Machine

S2

P2

Safety Sensor A

Safety Sensor B

Area A

Page 98: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Precau

tion

s

Safety Precautions

98G9SX USER'S GUIDE

<G9SX-GS@>( 1 ) Be sure to correctly connect safety input devices to safety

input A and safety input B to ensure proper operation of the safety functions.

( 2 ) When setting the Switching Function, be sure to consider safety control requirements, safety level and safety category of the entire system.

( 3 ) A qualified personnel who has a thorough understanding of the installed machine must switch the mode selector input. For example, a Switching Unit with Key must be used for the mode selector, and the key must be managed and used in such a way that the machine cannot be operated by unauthorized persons.

<G9SX-EX@>( 1 ) The durability of relays depend greatly on the switching

condition. Confirm the actual conditions of operation in which the relay will be used in order to make sure of the permissible number of switching operations.

■ Precautions for Correct Use<Precautions for All G9SX Models>( 1 ) Handle with care

Do not drop G9SX to the ground or expose to excessive vibration or mechanical shocks. G9SX may be damaged and may not function properly.

( 2 ) Conditions of storageDo not store in such conditions stated below.1. In direct sunlight2. At ambient temperatures out of the range of −10 to 55°C.3. At relative humidity out of the range of 25% to 85% or

under such temperature change that causes condensation.

4. In corrosive or combustible gases5. With vibration or mechanical shocks out of the rated

values.6. Under splashing of water, oil, chemicals7. In the atmosphere containing dust, saline or metal

powder.G9SX may be damaged and may not function properly.

( 3 ) MountingMount G9SX to DIN track with attachments (PFP-M, not incorporated to this product), not to drop off the track by vibration or other force especially when the length of DIN track is short compared to the widths of G9SX.

( 4 ) Following spacing around G9SX should be available to apply rated current to outputs of G9SX and for enough ventilation and wiring:1. At least 25 mm beside side faces of the G9SX.2. At least 50 mm above top face of G9SX and below

bottom face of G9SX.

( 5 ) Wiring1. G9SX

• Wire the G9SX as described below.

• Strip no more than 7 mm of insulation from the end of the wire.

• It is recommended that stranded wire be covered with insulated 0.25- to 2.5-mm2 ferrules before connecting it.

2. G9SX-@-RT (with Screw Terminals)• Tighten each screw to 0.5 to 0.6 N·m or the G9SX-@-

RT may malfunction or generate heat.3. Wiring for a Logical AND Connection

• Use a 2-conductor cabtire cable or shielded cable to wire a logical AND connection between Units.

( 6 ) Connecting Expansion Units (G9SX-EX@-@):(Only G9SX-AD@/-ADA@/-NSA@/-GS@)1. Remove the termination connector from the G9SX, and

insert the connector of the Expansion Unit into the G9SX to connect it.

2. Insert the termination connector into the last Expansion Unit as viewed from the G9SX. When the G9SX is used without any Expansion Units, do not remove the termination connector from the G9SX.

3. Do not remove the termination connector while the system is operating.

4. Before applying the power supply voltage, confirm that the connecting sockets and plugs are locked.

5. Make sure that all connected Expansion Units are supplied with power within 10 s after the power to the G9SX is turned ON. Otherwise, the G9SX will detect a power supply error for the Expansion Units.

( 7 ) Use cables with length less than 100m to connect to Safety Inputs, Feed-back/Reset inputs, or between Logical AND connection inputs and Logical AND connection outputs, respectively.

( 8 ) Set the time duration of OFF-delay to an appropriate value that does not cause the loss of safety function of system.

( 9 ) Logical AND connection between Units: 1. When using Logical AND connection inputs, set the

Logical AND connection preset switch to 'AND' position for the units which the logical AND connection signal are input to.

2. Connect Logical AND connection outputs appropriately to Logical AND connection inputs of the relevant unit. Verify the operation of G9SX before commissioning the system.

3. When configuring the safety related system, be sure to consider that the delay of response time caused by logical AND connections do not degrade the safety function of the system.

4. Use 2-conductor cabtire cable or shielded cable for logical AND connections between Units.

(10) To determine the safety distance to hazards, take into account the delay of safety outputs caused by the following times:1. Response time of safety inputs2. Response time of logical AND connection input

(Also consider the precaution in "Note" below)3. Preset OFF-delay time4. Accuracy of OFF-delay timeNote: When connecting multiple Units with logical AND

connections, the operating time and response time after logical AND connection inputs will be the sum of the operating times and response times of the Units that are connected in series by logical AND connections.

(11) Start entire system after more than 5s have passed since applying supply voltage to all G9SXs in the system.

25 mm min. 25 mm min.

50 mm min.

50 mm min.

T31 T32 T33T11

Y1 M1 M2T12 T61 T62 Y2 Y3

T21 T22X1 X2 X3 X4 S14 S24

T72T71 T41 T42

24VDC24VDC

T1

ERR

G9SX-GS226-T15G9SX-GS226-T15

EI

T6

FB

ED

UA

PWR

OFF-DELAY

UB

0.2 00.3

0.40.5

0.60.7 1 1.5 2 3

457

1015

T2

T7

AND

UA UBY4 A1

S44 S54L1 A2

No.No.

PWR

A2X244342414

A1

33 4313 23

No.

G9SX-EX401-T24VDC

PWR

A2X244342414

A1

33 4313 23

No.

G9SX-EX401-T24VDC

ED ED

ERR ERR

G9SX-NS20224VDC

No.

AND NS

FB

ERREI

PWB

D4L1S24S14A2X2T42T41

A1X1D2D1D3T32 T33T31

Solid wire 0.2 to 2.5 mm2 (AWG24 to AWG12)

Stranded wire 0.2 to 2.5 mm2 (AWG24 to AWG12)

Page 99: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Safety Precautions

G9SXUSER'S GUIDE 99

Precau

tion

s

(12) Power Supply1. The G9SX may malfunction due to electromagnetic

disturbances. Be sure to connect terminal A2 to ground.2. When sharing a power supply with a Safety Light

Curtain, use a power supply that will not fail for a momentary power interruption of 20 ms or less.

(13) Devices connected to G9SX may operate unexpectedly. When replacing G9SX, disconnect it from power supply.

(14) Adhesion of solvent such as alcohol, thinner, trichloroethane or gasoline on the product should be avoided. Such solvents make the marking on G9SX illegible and cause deterioration of parts.

<G9SX-NS/-NSA, D40A>For details, refer to D40A/G9SX-NS catalog (Cat. No. C160).

( 1 ) Connection with Non-contact Door SwitchWire conductors between the G9SX-NS@ and the D40A Non-contact Door Switch correctly and verify operation, before using the system.

( 2 ) The D40A must be used with a designated actuator and G9SX-NS@ Controller.

( 3 ) Use cables with a length of less than 100 m total to connect D40A Switches.

( 4 ) Disconnect the G9SX-NS@ from the power supply when replacing the D40A. Devices connected to the G9SX-NS@ may operate unexpectedly.

( 5 ) Do not use the D40A in a magnetic field of 1.5 mT or higher. The D40A may not function properly.

( 6 ) Do not use the D40A in the water or in an environment continuously exposed to water. Water may penetrate into the D40A. (The IP67 degree of protection for this switch means that it has been checked for penetration of water after having been left in water for a fixed period of time.)

( 7 ) Be sure to mount a guard stopper and guide to prevent the D40A Non-contact Door Switch from being subjected to impact.

( 8 ) Do not use the switch or actuator as a stopper. Protect the switch and the actuator by installing a stopper. Separate the switch and the actuator to a distance of 1 mm or more.

( 9 ) Install the actuator and switch at an appropriate distance so that they do not create a gap that provides access to the hazard.

(10) Where two or more Switches are mounted side-by-side, they must be no closer than 25 mm.

(11) Check that the machine is stopped whenever the interlocked guard door is open.

(12) Do not mount the switch and actuator on magnetic materials, otherwise it may affect the operating distance. Below are reference values of the effect to the operating distance.

(13) Tighten all screws to the specified torque by using non-magnetic M4 screws and washer for the installation of the switch and actuator. After installation and using, the actuator and switch fixing screws must be coated with tamper proof varnish or similar compound. Using anaerobic locking compounds can have a detrimental effect on the plastic switch case if the compounds come into contact with the switch case.

(14) Wiring1. Use the following to wire to the product.

Stranded wire (flexible wire): 0.2 to 2.5 mm2 (AWG24 to AWG12)Solid wire (steel wire): 0.2 to 2.5 mm2 (AWG24 to AWG12)

2. When an auxiliary output is not used, cut off the wiring and cover it with tape so that it does not contact other terminals.

<G9SX-GS>( 1 ) Use a mode selector that has an SPST-NO + SPST-NC

contact form (e.g., OMRON's A22K-@-11).

Total wiring length 100 m max.

D1 D2 D3 D4

G9SX-NS202-@G9SX-NSA222-T03-@

25 mm min.

Distance from surface of magnetic material

Operating distance

0 to 5 mmDecrease to approx. 90% of rated value.

> 5 mm No effect

Switch

Actuator

Page 100: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Precau

tion

s

Safety Precautions

100G9SX USER'S GUIDE

■ Category of EN 954-1In the condition shown in Application Examples, G9SX can be used for the corresponding categories up to category 4.This does NOT mean that G9SX can always be used for required category under all the similar conditions and situations.Conformity to the categories must be assessed as a whole system.When using G9SX for safety categories, be sure to confirm the conformity as a whole system.

To conform with Safety Category 4 (EN954-1)When using Non-contact Door Switch D40A/G9SX-NS@, the system can be used for the corresponding categories up to category 3.1. Input the signals to both of the safety inputs (T11-T12, T21-T22,

T61-T62 and T71-T72).

2. Input a signal to the safety inputs (T11-T12, T21-T22, T61-T62 and T71-T72) through switches with Direct Opening Mechanism.When using Limit Switches, at least one of them must have Direct Opening Mechanism.

3. When connecting Safety sensor with G9SX, use TYPE 4 safety sensor.

4. Input the signal through a NC contact of the contactor to Feedback/Reset input (T31-T32 for manual reset or T31-T33 for auto reset). (Refer to Application Examples)

5. Keep Cross fault detection mode input (Y1 and Y2) open. However, when connecting devices with self-diagnosis function, such as safety sensors, apply 24VDC to Y1 and Y2.

6. Be sure to Connect A2 to ground.7. When using a G9SX-EX-@-@ Expansion Unit, connect fuses

with a current rating of 3.15 A max. to the safety relay outputs to prevent the contacts from welding.

■ Compliance with International Standards

ItemModel G9SX-AD

G9SX-ADAG9SX-NS

G9SX-NSAG9SX-BC G9SX-GS G9SX-EX

Approved by TÜV Product Service

EN50178 ❍ ❍ ❍ ❍ ❍

IEC/EN60204-1 ❍ ❍ ❍ ❍ ❍

EN954-1 Cat.4 ❍ ❍ ❍ ❍

EN954-1 Cat.3 ❍

IEC/EN61508 SIL3 ❍ ❍ ❍ ❍ ❍

IEC/EN62061 SIL3 ❍

IEC/EN61000-6-2 ❍ ❍ ❍ ❍

IEC/EN61000-6-4 ❍ ❍ ❍ ❍

IEC/EN60947-5-2 ❍

IEC/EN60947-5-3 PDF-M ❍

Approved by UL

UL508 ❍ ❍ ❍ ❍ ❍

UL1998 ❍ ❍ ❍ ❍ ❍

NFPA79 ❍ ❍ ❍ ❍ ❍

IEC61508 ❍ ❍ ❍ ❍ ❍

CAN/CSA C22.2 No.142 ❍ ❍ ❍ ❍ ❍

Approved by KOSHA ❍ ❍ ❍ ❍

Page 101: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

MEMO

G9SXUSER'S GUIDE 101

Page 102: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

MEMO

102G9SX USER'S GUIDE

Page 103: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

READ AND UNDERSTAND THIS CATALOGPlease read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.

Warranty and Limitations of LiabilityWARRANTYOMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITYOMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application ConsiderationsSUITABILITY FOR USEOMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product.

At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this

document.

• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

DisclaimersCHANGE IN SPECIFICATIONSProduct specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.

DIMENSIONS AND WEIGHTSDimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONSThe information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.

PERFORMANCE DATAPerformance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.

PROGRAMMABLE PRODUCTSOMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.

Copyright and Copy PermissionCOPYRIGHT AND COPY PERMISSIONThis document shall not be copied for sales or promotions without permission.This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.

Page 104: USER'S GUIDE - Support Omron · A2 S14 S24 S34 S44 S54 L1 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A2 S14 S24 L1 L2 X1 X2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 S2 12 11

Authorized Distributor:

Note: Specifications subject to change without notice.

Regional Headquarters

Cat. No. Z255-E1-01Printed in Japan0807-0.3M (0307) (M)

OMRON CorporationIndustrial Automation Company

Safety Devices DivisionShiokoji Horikawa, Shimogyo-ku,Kyoto, 600-8530 JapanTel: (81) 75-344-7093/Fax: (81) 75-344-8197

OMRON EUROPE B.V.Wegalaan 67-69, NL-2132 JD HoofddorpThe NetherlandsTel: (31)2356-81-300/Fax: (31)2356-81-388

OMRON ASIA PACIFIC PTE. LTD.No. 438A Alexandra Road # 05-05/08 (Lobby 2),Alexandra Technopark, Singapore 119967Tel: (65) 6835-3011/Fax: (65) 6835-2711

OMRON (CHINA) CO., LTD.Room 2211, Bank of China Tower,200 Yin Cheng Zhong Road,Pu Dong New Area, Shanghai, 200120, ChinaTel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

OMRON SCIENTIFIC TECHNOLOGIES INC.6550 Dumbarton Circle, FremontCA 94555-3605 U.S.A.Tel: (1) 510-608-3400/Fax: (1) 510-744-1442