CATALOGChapter1Introduction............................................................................................................................ 3
1.1BriefIntroductionofPerformanceFeatures............................................................................. 3
1.2SystemStructure....................................................................................................................... 3
1.3OperatingMode ........................................................................................................................ 4
1.4FunctionsandCharacteristics ................................................................................................... 6
Chapter2InstallationInstruction ........................................................................................................... 8
2.1UnloadingandUnpacking ......................................................................................................... 8
2.2SiteSelection........................................................................................................................... 12
2.3InstallationofUPS ................................................................................................................... 12
2.4CableSelectionandConnection ............................................................................................. 13
2.5BatteryConnection ................................................................................................................. 15
Chapter3Operation ............................................................................................................................. 18
3.1IntroductionofOperationInterface ....................................................................................... 18
3.2
Operation
for
Power
on
of
Single
Machine............................................................................. 193.3OperationforPoweroff.......................................................................................................... 27
3.4OperationforEmergencyPoweroff....................................................................................... 28
3.5OperationforMaintenanceBypass ........................................................................................ 28
3.6EnquiryOperation ................................................................................................................... 29
3.7OperationsforUserConfiguration.......................................................................................... 37
Chapter4InstallationandOperationofParalleledMachine ............................................................... 49
4.1InstallationofParalleledSystem............................................................................................. 49
4.2On/OffofParalleledMachines................................................................................................ 50
4.3EnquireOperationofParalleledSystem ................................................................................. 51
Chapter5:UPSRepairingandMaintenance......................................................................................... 53
5.1UPSRepairingandMaintenance............................................................................................. 53
5.2Troubleshooting ...................................................................................................................... 545.3MaintenanceAssurance.......................................................................................................... 58
5.4TechnicalSpecifications .......................................................................................................... 58
Appendix1:LampSignalReferenceList ............................................................................................... 61
Appendix2:PortofCommunicationInterface ..................................................................................... 63
Appendix3:DialSwitchSetofModuleandCharger ............................................................................ 65
-
8/13/2019 Usermanual-11295075930
2/66
2
PREFACE
Thankyouforusingourproducts.
Our company is engaged in developing andmanufacturingproductsof uninterruptedpower
system which is a kind of power product with high quality and can meet various performance
requirements.
Note:Thismanualcontains instructionofmounting,application,andoperationofUPS. Itshall read
thismanualcarefullybeforemounting thesystemand it isnotallowed to takeanyoperationson
UPSbefore finishing readingall safety instructionandoperation instruction.Thismanualcontains
significant information,pleaseobey allwarningsandoperation instructions statedby themanual
andmachine,andthemanualshallbekeptwell.
SafetyTheuninterruptedpowersystemmustbegroundedbeforeoperation.
Battery shall be replaced by qualified maintenance personal. The battery is toxic waste
according to laws, so wasted battery shall be recovered by its classification in accordance with
requirementofenvironmentalprotection.
WarningSellingof thisproduct isonly forpartnerwhohasgeneral informationonUPSproducts. It is
necessarytoknowsomeothermountingrequirementsormeasurestopreventaccident.
Anycontentof themanualshallnotbemodifiedwithoutallowanceofmanufacturerandanyoffendersmustbeinvestigated.Ourcompanyreservestherightoffinalinterpretation.
-
8/13/2019 Usermanual-11295075930
3/66
3
Chapter1Introduction
1.1Brief
Introduction
of
Performance
Features
900II1060KVA(3/3)seriesisakindofhighfrequencyUPSwiththreeinletandthreeoutlet
designedbyfulldigitalcontroltechnology.Thedesignofunitbreaksconventionaldesignthoughtof
towertypemachine,replacedbyadvancedmodulardesignideawhichcanensurecompactnessof
layoutandimprovereliabilityoftheunit.Electricalperformanceof900II1060KVA(3/3)seriesis
advantageousandprotectionofsoftwareandhardwareofitisperfect.Itisapplicablefordifferent
powergridandcansupplysafeandreliablepowerfordifferentloads.
1.2SystemStructure
Componentsofthesystemmainlyinclude:LCDdisplayscreen,communicationport,power
module,charger,battery(optional),inputbreaker,outputbreaker,maintenancebypassbreaker,
groundrow,Nrow,andsoon.Itssystemstructurechartisshowninfigure1.1andfigure1.2.
Figure1.1Structureof900II1030KVAseries
-
8/13/2019 Usermanual-11295075930
4/66
4
Figure1.2Structureof900II4060KVAseries
1.3OperatingMode
900II1060KVAisakindofonlinedoubleconversionUPS,itsoperatingmodesareasfollows:
Mainpowersupplymode Batterymode Bypassmode Maintenancemode(manualbypass) Frequencyconvertermode1.3.1Mainpowermode
TheworkingmodethatalternatingcurrentpowerofrectifiercircuitforUPSissuppliedbymain
power, direct current power for inverter is supplied after corrected by PFC power factor, and
continuousanduninterruptedalternating currentpower for load isprovidedby inverter circuit is
calledmainpowermode.Thechargerwillstartautomaticallyafterpoweronof invertertosupply
powerforbattery.
-
8/13/2019 Usermanual-11295075930
5/66
5
AC/DCrectification
Charger
DC/DCboost
BATTERY
+ -
DC/ACinverter OutputMain powerinput
Maintenancebypass
Bypass
Figure1.3WorkingProcessChartunderMainPowerMode
1.3.2Batterymode
Theworkingmode that battery power is boosted through battery booster circuit, and then
suppliedtoloadthroughinvertercircuitiscalledbatterymode.Whenmainpowerfaultoccurs,the
systemwillswitchtobatterymodeautomaticallyandpowersupplyforloadisnotinterrupted.When
main power recoveries, the system will switch to main power mode automatically without any
manualoperationandpowersupplyforloadisnotinterrupted.Switchingtimeofmainpowermode
andbatterymodeis0ms.
AC/DCrectification
Charger
DC/DCboost
BATTERY
+ -
DC/ACinverter Output
bypass
Maintenancebypass
Mainpoweinput
Figure1.4WorkingProcessChartunderBatteryMode
1.3.3Bypassmode
Iffaultsuchasinvertercircuitfaultandinvertercircuitoverload,orswitchingtobypassmode
byhandoccurs,theUPSwillswitchtheloadfromsideofinvertertosideofbypassandpowersupply
fortheloadisnotinterrupted.
-
8/13/2019 Usermanual-11295075930
6/66
6
AC/DCrectification
Charger
DC/DCboost
BATTERY
+ -
DC/ACinverter OutputMainpowerinput
Maintenancebypass
Bypass
Figure1.5WorkingProcessChartunderBypassMode
1.3.4Maintenancemode(manualbypass)
IfitneedstomaintainorrepairtheUPS,itcanclosethemanualbypassswitchtoswitchtheUPS
tothesideofmaintenancebypassandthepowersupplyforloadisnotinterrupted.Inthatcase,the
mainpowerwillnotpasstheinternalcomponentsofmachinebutconnecttheinputterminaland
outputterminaldirectlysothatwecanmaintainorrepairtheUPS.
Figure1.6WorkingProcessChartunderMaintenanceBypassMode
1.3.5Frequencyconvertermode
UPScanbesettofrequencyconvertermodewhichcanprovidestableoutputfrequencyof50Hz
or60Hz.Inputfrequencyrangeofmainpoweris40Hz 70Hz.UPSwilloutputthesetoutput
frequencyandthebypassmodeisineffectiveunderfrequencytransformermode.Whenmainpower
isabnormal,thesystemwillswitchtobatterymodeautomaticallyandstilloutputwiththeset
outputfrequency.
1.4FunctionsandCharacteristics
DSPfulldigitalcontroltechnology; Pureonlinedoubleconversionframework,strongloadcapability; Input power factor is as high as more than 0.99, low harmonic current, environmental
protection,highefficient,andenergysaving;
Wide inputvoltagerange,50/60Hzpowersystemselfadoptionsuitableforallgridunderanycircumstance;
Supportfrequencymodesof50Hzinput/60Hzoutputand60Hzinput/50Hzoutputwhich
-
8/13/2019 Usermanual-11295075930
7/66
7
canmeetspecialrequirementsofuser;
AdvancedN+Xwirelessparallelconnectionredundanttechnique,highparallelreliabilityandsmallcirculation;
Parallelmachinessharethebatterygroupwhichcansavecellinvestmentfromuser; Digitalchargerwithflexiblechargingparametersetandbatterypiecesselection; Advancedbatteryintelligentmanagementtechnologywhichcanprolongworkinglifeofbattery
effectively;
Supportcoldstartofbatteryandautomaticstartofnormalpowerwhichcanmeetusersapplicationrequirements;
Easilydamagedcomponentsarecompletelyisolatedwithairfluewhichcanimprovereliabilityofthesystemeffectively;
Easilydamagedcomponentscanbechangedinmodulelevel,fieldreplacementisfastandconvenientandmodulecostislow;
Perfecthardwareandsoftwareprotectionfunction(breaker,Fuse,hardwareprotection,andsoftwareprotection),superselfdiagnosis,andrichhistoricrecordenquiry;
5.7inchLCDtouchwidescreendisplay,friendlyhumanmachineinterface; Manycommunicationports,includingRS232,RS485,USB,drycontactcardandSNMPsmart
cardtrough.
-
8/13/2019 Usermanual-11295075930
8/66
8
Chapter2Installation
Instruction
2.1UnloadingandUnpacking
Usershallcheckthepackagetoconfirmitisundamagedafterreceivingtheproduct;thenopen
thepackagetocheckwhethertheequipmentisundamaged,andpleasecontactthecarrieratonceif
itisdamaged.
2.1.1Openofcabinetpackage
1)Putthepackingboxvertically;
Figure2.1PackingBoxPlacement
2)Openthetopplateofpackingboxandthentakeoutthefoam;
-
8/13/2019 Usermanual-11295075930
9/66
9
Figure2.2UnsealthePackingBox
3)Unsealsideplatesofpackingboxandthentakeoutthefoams.
-
8/13/2019 Usermanual-11295075930
10/66
10
Figure2.3UnsealedCabinet
Tips:Itshallbecarefulwhenunsealingtopreventscratchforthemachinebody.
Checkwhetherthequalifiedcertificate,instructionbook,CDdisk,andkeysforfrontandback
doorsarecompleteornotafteropeningthepackingbox.
3.1.2Openofmodulepacking
1)Placethepackingboxinstable;
-
8/13/2019 Usermanual-11295075930
11/66
11
Figure2.4OuterPackingofModule
2)Cutofftheplasticbelts,removethescotchtape,andthenopenthepaperbox;
paperbox Foampacking
Figure2.5ModuleUnpacking
3)Removecoveroffoampacking,theequipmentwithplasticpackingwillappear;
Coveroffoampacking
Paperbox
Equipment
Foampacking
Figure2.6TakingoutofModule
-
8/13/2019 Usermanual-11295075930
12/66
12
4)Finally,takeouttheequipmentwithplasticpacking,andthenremovetheplasticpacking.
Tips:appendixesalongwithcabinetandmodulesshallbekeptwell,especialthatthemanual
andCD
disk
contain
much
important
safety
instruction,
please
do
not
operate
the
equipment
beforereadingthewholesafeoperationinstruction.Allwarningsandoperationsshownby
machineandmanualshallbeobeyedstrictly.
2.2SiteSelection
Placedlocationmustbestable; EnoughventilationspacemustbeleftbetweenallsurfacesofUPSandwalls; Befarawayfromhotsourceandcorrosivematerials,avoidthesunshine; Keep normal working temperature and elevation height (working temperature: 0
40,itneedstobeappliedbyderatingifelevationheightexceeds1500m); Keep clean working environment, avoid environment with moisture, flammable gas,
flammableliquid,orcorrosivematerial;
Weightcapabilityoffloortomachineandbatterygroupshallbeconsideredbeforemounting.
2.3InstallationofUPS
1.PutUPSmachineinspecificlocation.
LocationofplacingtheUPSshallbeproperinordertoensuresafetyapplicationofUPS.Itshall
beplacedinplacewithcleanenvironmentwithoutmoisture,flammablegas,flammableliquidor
corrosivematerialandsunshine.Usercanputitonassignedlocationwithassistantofhumanforce
orequipmentandshallpayattentiontospacesbetweenUPSandsurroundingthingswhenmounting
sothatitishelpfulforventilationandheatdissipation.Minimumspaceisshowninfigure2.7(unit:
mm):
Figure2.7CabinetPlacementChart
-
8/13/2019 Usermanual-11295075930
13/66
13
2.InsertthepowermoduleintoUPSinlocationshowninFigure1.1andthenfixthemodule
withHuangguanscrew.
Tips:
1.Moduleissoheavythatitneedsmorethan2personstoputitintothecabinet.
2.Itshallbeslowwheninsertingthemoduleuntilitisinsertedfully.
2.4CableSelectionandConnection
2.4.1Selectionofcable
Whenselectingconnectingcableforthesystem,itissuggestedtoselectthewirediameterof
cableaccordingtomaximumpowerconfigurationof900II1060KVAsystemandcomplyinglocal
connectionrulesandenvironmentalcondition(temperatureandphysicalsupportmedia).Thecable
shallbeselected
according
tomaximum
steady
state
alternating
and
direct
currents
of900II
10
60KVA,anditsselectionconditionsarelistedintable2.1:
Table2.1CableConfigurationTable
Rated380Vinput
UPSratedpower
Inputcurrentwhenitis
fullloadandcharger
outputsmaximumpower
Output
currentwhen
itisfullload
Discharging
currentof32
pieces
batteries
10KVA 24A 15A 28A
15KVA 31A 23A 41A
20KVA 39A 30A 55A
30KVA 53A 46A 83A40KVA 78A 61A 110A
60KVA 107A 91A 165A
2.4.2Connectionofcable
Batteryinput(longtermmachine),mainpowerinput,bypassandoutputcableshallbe
connectedwithUPSaccordingtothepathsshowninFigure2.8.
Chart for System Base
BatteryinletwiringchannelMainpowerinputinletwiringchannelBypasswiringinletchannelOutput
inlet
wiring
channel
Figure2.8InletandOutletWiringChannelof900II1060K
-
8/13/2019 Usermanual-11295075930
14/66
14
Connectionofcableis:
1.Openthedistributionboardtoexposethecopperrows.
Figure2.9FrontViewofCabinet
2.Phasesshowninfollowingfigurearelinebanksofmainpowerinput,bypassinput,battery
inputandoutputcableafterpassingtheinletandoutletwiringchannels.
Figure2.10DistributionWiringDiagramof900II1030KVAseries
-
8/13/2019 Usermanual-11295075930
15/66
15
Figure2.11DistributionWiringDiagramof900II4060KVAseries
Tip:pleasetightentheinputandoutputcablesandwiringrow.
3.Recoverthedistributionpanel
2.5Battery
Connection
2.5.1Batteryconnectionoflongtermmachine
Batterygroupforthismachineispositiveandnegativebatterygroupframework,totalnumber
ofbatterycanbeselectedfrom32to40(evennumber),andquantitiesofpositiveandnegative
batteriesshallbethesame.
Batteryconnectionchartisshowninfigure2.12:
Figure2.12BatteryConnectionChart
-
8/13/2019 Usermanual-11295075930
16/66
16
Asshowninfigure2.12,connectallbatteriesinseries,andleadaNlinefrommiddleconnection
pointofbatterygroups,soitshallbethreelinestogetherwithpositiveandnegativeendsofbattery
grouptoconnectwithbatteryconnectingterminalsofUPS.Batteriesbetweenpositiveendof
batterygroupandNlinearecalledpositivebatteries,andbatteriesbetweennegativeendofbatterygroupandNlinearecallednegativebatteries.Usercanselectthecapabilityandnumberofbattery
accordingtoitsdemand.ItmustaddanalternatingcurrentbreakerbetweenbatterygroupandUPS
toplayaroleofcurrentlimitingprotectionandopenandclosethebatterygroupwhenmaintaining.
2.5.2Installationandmaintenanceofbatteryforstandardmachine
1.Installationofbatterypack:
1)Openthebatterypackpanelinfrontofcabinettoexposethebatterypack.
Figure2.13BatteryPack
Note:itneedstoturnonthechargersolelybeforeinstallingthebatteryforthefirsttimetoinspect
whethertheoutputvoltageofchargerisnormal.
2)Removethesetscrewsofbatterypackandextractthebatterypack.
3)PutbatteriesintobatterypackasshowninFigure2.14(batterypositiveandnegative
terminalsmustbelocatedontherightsideofthebatterypackwheninstallingthebatteries).
+-+-+-+-+-+-+-+-
Figure2.14RightViewofBatteryPack
4)Putthebatterypackwithbatteriestocorrespondinglocationandlockthesetscrews.
-
8/13/2019 Usermanual-11295075930
17/66
17
5)Measurewhetherthevoltageofeverybatterypackisnormal,thenmeasurewhetherthe
sideleadterminalisshortcircuit,ifallofthemisnormal,connectthebatterypackwithUPS
accordingtotheconnectingmethodshowninfollowingfigure2.15
Figure2.15ConnectingDiagramofBatteryPack
6)Recoverthebatterypackpanel.
Maintenanceofbatterypack:
1) SwitchtheUPStomaintenancebypassmode.
2) Removethebatterypackpaneltoexposethebatterypack.
3) Cutofftheconnectinglineofbatterypack(asshowninFigure2.15).
4) Takeawaythesetscrewofbatterypackandthentakeawaythebatterypack.
5) Replacethebatteryaccordingtothedemand.
6) Recoverthebatterypack.
Thefollowingsafetynotesshallbenotedallthetimewhenmountingandmaintainingthe
batteries:
1).Electricshockmayoccurwhenmountingthebatteries,highshortcircuitcurrentmaycause
fire;
2).Voltage of battery groups can be 480Vdcwhichmay cause death, so please obey safety
attentionsforvoltageoperation;
3).Only
qualified
personal
can
mount
and
maintain
the
batteries;
4).Wearprotectiveeyeweartopreventaccidentcausedbyelectricarc;
5).Takeoffring,watch,necklace,bracelet,andotheraglets;
6).Usetoolswithinsulatedhands;
7).ItshallbreakdownthebreakerofbatterywhenconnectinglinesbetweenUPSandbattery.
It must ensure that the sequence and polarity of connection are correct after finished
connection;
8).Pleasecontactcustomerservicedepartmentofourcompanyiftheuserneedstochangethe
numberofusedbatteriesduringnormalapplication.Pleasedonotoperateitsolely.
-
8/13/2019 Usermanual-11295075930
18/66
18
Chapter3Operation
ThischapterdescribesallenquiriesandsettingoperationsofUPStakenbyoperator,including
startingofUPS,poweroffofUPS,allenquiryoperations,andparametersetting,etc.
Tips:instructionmanualmustbereadcarefullybeforeimplementingthefollowingoperations
toavoidpersonalinjuryorequipmentdamagecausedbymisoperation.
3.1IntroductionofOperationInterface
AsshowninFigure3.1,operationinterfacemainlycontains:LEDindicatorlight,5.7inch
multifunctionalLCDtouchwidescreenandoperationbutton.
FAULT
BYPSS
BATTERY
NOMAL
EPO
TAB
UP
DOWN
ENTER
CANCEL
COLD START
IndicatorlightOperationbutton
ColdstartLCDwidescreen
Figure3.1MonitoringInterface
DefinitionsoficonsonpanelsilkscreenandLCDscreenarelistedintable3.1:
Table3.1Silkscreen/IconIllustration
Monitoringpanel Icon/Silkscreen Meaning
FAULT Warn
BYPASS Powersuppliedbybypass
BATTERY Powersupplierbybattery
LEDindicatorlight
NOMAL Powersuppliedbymainpower
Setting
Charger
Battery
On/Off
Inputparameter
Outputparameter
Returntomaininterface
Returntopreviousmenu
-
8/13/2019 Usermanual-11295075930
19/66
19
Pagedown
Pageup
History
Selftestandmuteoff
IconsonLCD
touchscreen
Recordenquiry
TAB Switchoftouch/buttoncontrol
UP Cursorup
DOWN Cursordown
ENTER Confirm
CANCEL Return to touchcontrol from button
control
COLDSTART Coldstart
Operationbuttons
EPO Emergencypoweroff
LCDscreensupportstwokindsofcontrolmodes,buttoncontrolandtouchcontrol.
1.Buttoncontrol
PressbuttonofTABunderanyinterfacetoswitchtobuttoncontrolmode,theselectedicon
isdisplayedinreverse,movethecursorbypressingbuttonofUPorDOWN,pressENTERto
selecttheiconwherecursorlocatesat,andpressCANCELtoreturntotouchscreencontrolmode.
2.Touchcontrol
TakeoperationsbyclickingcorrespondingiconsonLCDscreen.
3.2OperationforPoweronofSingleMachine
Note:
Itshallcheckwhetherallscrewsarefastenedandallconnectionsarecorrectornotbefore
startingthemachine.Input,output,andbatterybreakersshallbeinoffstate.
Forlongtermmachine,itshallsetthechargerparameterss(inChapter3.7.9)beforestarting,
andbatterypiecesandgroupsshallbematchwiththebatterygroup.(Setbyprofessionalpersonal
ofourcompany)
3.2.1Startundermainpowermode
1.Startmainpowermodedirectly
1)Connectthemainpower
ClosetheinputandbypassbreakerandUPSconnecttothemainpowerandbypass.TheUPS
screenstartstoworkandthenLOGOinterfaceoccurs.
-
8/13/2019 Usermanual-11295075930
20/66
20
Figure3.2LogoInterface
Itwillberefreshedtomaininterfaceafter1s.
Figure3.3MainInterface
Clicktheiconofbatterytocheckwhetherthebatterysetismatchwithactualbattery
configuration(detailoperationcanbeseenin3.6.5).
2)StartUPS
ClickiconofOn/OffinmaininterfacetopoptheinterfaceofOn/Off.
IfitisthefirsttimetostarttheUPS,userneedtoentertheUPSonpassword,thenumberis
19841219.Afterthistime,nopasswordisneededtostarttheUPS.
-
8/13/2019 Usermanual-11295075930
21/66
21
Figure3.4UPSONpassword
ClickiconofINVONandthenUPSstartstopoweronundermainpower.
Figure3.5On/OffInterface
ProcessofstartingUPSundermainpowermodewillbefinishedafteratime,andthenthe
indicatorlightinfrontpanelofpowermoduleison.
Thechargerstartstopoweronautomaticallyafterthepowermoduleisstarted,andthe
startingofchargermoduleisfinishedafteratime.
3)Closebatteryandoutputbreakers
Closethebatterybreak(longtermmachine)andoutputbreakerafterstartingofUPSunder
mainpowerisfinished,andthentheUPSstartnormaloperation.
EnergyflowafteritisstartedundermainpowermodeisshowninFigure3.6:
-
8/13/2019 Usermanual-11295075930
22/66
22
Figure3.6OperationsunderMainPower
2.SwitchfrombypassmodetomainpowermodeIftheUPSisworkingunderbypassmode,clicktheOn/Officoninmaininterfacetopopthe
On/Offinterface.
Figure3.7On/OffInterface
ClickiconofTOINV,theUPSwillbegintostartthemainpowermode,andstartingunder
mainpowermodewillbefinishedafteratime.
3.2.2Starting
under
battery
mode
Ifmainpowerisfault,UPScanbeturnedonbybatterymodedirectly.
1.Closebatterybreaker,inputbreakerandbypassbreakerandconnectthebattery.
2.PressbuttonofCOLDSTARTincontrolpaneltoturnontheLCDscreen.LCDscreendisplays
maininterface.
3.PressENTERfor2stobuildworkingpowerforpowermodule,andthenthefanofmodule
startstorotate.Clickthebatteryicontocheckwhetherthebatterysetisthesamewithactual
batteryconfiguration(Detailedoperationisshownin3.6.4and3.6.5).
-
8/13/2019 Usermanual-11295075930
23/66
23
Figure3.8MainInterface
4.ClickOn/OfficoninmaininterfacetopoptheOn/Offinterface.ClickiconofINVON,andthestartingunderbatterymodewillbefinishedafteratime.
Figure3.9On/OffInterface
5.Closeoutputbreaker,andthentheUPSoutputisnormalandstartingbybatteryisfinished.
Itsenergyflowisshowninfigure3.10:
-
8/13/2019 Usermanual-11295075930
24/66
24
Figure3.10BatteryMode
3.2.3Startingunderbypassmode
Itcanswitchtobypassmodedirectlyundermainpowermodeorunderthecasethatmain
powerisavailablebuttheUPShasnotbeenstartedyet.
1.Startthebypassmodefromstandbymode(mainpowerisavailablebuttheUPShasnotbeen
startedyet).
TheUPShasnotbeenstartedcurrently,anddisplayofitsmaininterfaceisshowninFigure3.11:
Clickthebatteryicontocheckwhetherthebatterysetisthesamewithactualbattery
configuration.
Figure3.11MainInterface
1)ClickOn/OfficoninmaininterfacetopoptheOn/Offinterface.
-
8/13/2019 Usermanual-11295075930
25/66
25
Figure3.12On/OffInterface
2)ClickiconofBYPON,UPSwillenterthebypassmode,andthebypassmodeisstarted.The
chargerwillstartautomaticallyafteratime.
3)Closebatterybreaker(longtermmachine)andoutputbreaker,andthebypassstartstooutput
normally.
Itsenergyflowchartisshowninfigure3.13:
Figure3.13BypassMode
2.Switchtobypassfrommainpowermode
TheUPSisworkingundermainpowermodecurrently,clickiconofOn/Offinmaininterfaceto
poptheOn/Offinterface.
-
8/13/2019 Usermanual-11295075930
26/66
26
Figure3.14On/OffInterface
ClickiconofTOBYP,andthenthesystemwillenterintobypassmode.
3.2.4Startcharger
1.ChargerwillstartautomaticallytochargethebatterywhenUPSisstartedundermainpower
modeorbypassmode.
2. If the charger isoff andneeds tobe restarted,when theUPS is inmain powermodeor
bypassmode,itcanclicktheOn/OfficoninmaininterfacetopoptheOn/Offinterface,clickiconof
CHGONbelowtheCHG_ON/OFF,andthenthechargerwillbestarted.
3.Clicktheiconofchargerinmaininterfacetochecktheworkingstateofcharger.
Figure3.15On/OffInterfaceofCharger
3.2.5Startingbymanualselftest
InordertoensurethebatterystateofUPSandprolongworkinglifeofbattery,itneedsto
chargeandreleaseelectricityofthebatteryperiodicallytoensurethatthebatterycansupplypower
forUPSnormallywhenmainpowerfailssuddenly.
Clickiconofselftestandmuteoffinmainscreen,thepoppedinterfacesincludeTEST10S,
TEST10M,TESTLOW,CLRTEST,andMUTE.Clickoneofthefirstthreeoptionstoselectthe
selftesttime.Selectdifferentselftesttimesaccordingtothetimeofactualtestperiod.
-
8/13/2019 Usermanual-11295075930
27/66
27
Figure3.16SelftestandMuteoffInterface
3.3OperationforPoweroff
3.3.1Poweroffunderlinemode
TheUPSisworkingundermainpowermodecurrently.
ClickiconofOn/OffinmaininterfacetopoptheOn/Offinterface.ClickiconofSHUTtoshut
downtheUPS,andthechargerwillbeoffautomaticallyatthesametime.
Figure3.17InterfaceofPoweroffunderMainPower
3.3.2Poweroffunderbatterymode
TheUPSisworkingunderbatterymodecurrently.
ClickiconofOn/OffinmaininterfacetopoptheOn/Offinterface.ClickiconofSHUTtoshut
downtheUPS.
3.3.3Poweroffunderbypassmode
TheUPSisworkingunderbypassmodecurrently.
-
8/13/2019 Usermanual-11295075930
28/66
28
Click iconofOn/Off inmain interfacetopoptheOn/Off interface.Click iconofBYPOFFto
shutdowntheUPS,andthechargerwillbeoffautomaticallyatthesametime.
3.3.4Power
off
the
charger
1.Thechargerwillbeoffautomaticallyifthemachineispoweredoffundermainpowermode
orbypassmode.
2.Poweroffthechargerwhenthemachineisworkingundermainpowermodeorbypassmode:
1)ClickiconofOn/OffinmaininterfacetopoptheOn/Offinterface.
Figure3.18PowerOffInterface
2)ClickiconofCHGOFFbelowCHGON/OFFtopoweroffthecharger.
3.4OperationforEmergencyPoweroff
Emergencypoweroff(EPO)switchisusedtopowerofftheUPSunderemergencysituation
(suchasfire,flood,etc.).PressbuttonofEPOinmonitoringpanel,theUPSwillcutoffoutputatonce
andcutoffthepowerinseveralseconds.
Ifitneedstopoweronthemachineagain,itshalltakethepoweronoperationaftercuttingoff
themainpowerinputbreakerandbypassbreakerfor30s.
3.5OperationforMaintenanceBypass
3.5.1Startofmaintenancebypass
1.SelectoptionofOn/OffinLCDmaininterface,selecticonofTOBYPinOn/Offinterface,and
confirmtheUPSisworkingunderbypassmodeinLCDscreen.
-
8/13/2019 Usermanual-11295075930
29/66
29
Figure3.19BypassMode
2.Openthecoverofmaintenancebypassbreaker,closethemaintenancebypassbreaker,cut
offtheinput,output,andbatterybreakers,andthentheUPSentersintomaintenancebypassmode.
Itsenergyflowisshowninfigure3.20,andthencutofftheinputandbypassbreakers.
Figure3.20MaintenanceBypassMode
3.5.2Exitofmaintenancebypassmode
1.Closetheinputbreakerandbypassbreaker,thepowermodulebuildsworkingpowerand
switchestobypassmodebyhand,chargerstartsautomatically.
2.Closetheoutputbreakerandbatterybreaker,cutoffmaintenancebypassbreaker,putback
thebaffleofmaintenancebypassbreakerback,andthenthewarningmaintenancecover isopen
inLCDscreendisappears.
3.SelectoptionofOn/OffinLCDmaininterface,selectTOINVinOn/Offinterface,thepower
modulewillstarttheinverterafter20s,andthenUPSwillbeworkingundermainpowermode.
3.6EnquiryOperation
EnquiryoperationisaparametertoinquirytheworkingconditionandsettingofUPS.
-
8/13/2019 Usermanual-11295075930
30/66
30
3.6.1Enquiryofinputinformation
ClickI\Pinmaininterfacetopoptheinputparameterinterface.Theinputparameter
interfacewilldisplayinformationincludinginputvoltage,inputfrequency,bypassvoltage,bypass
frequency,UPStemperature,etc.
Figure3.21InputParameterInterface
3.6.2Enquiryofoutputinformation
ClickO/Pinmaininterfacetopoptheoutputparameterinterface,andtheninformation
includingoutputvoltage,outputcurrent,outputfrequency,activepower,apparentpower,andload
factorofthreephaseswillbedisplayed.
Figure3.22OutputParameterDisplay
3.6.3Enquiryofinformationofcharger
Clickiconofchargerinmaininterfacetoinquiryinformationofcharger.
Informationofchargerincludes:stateofchargerandparameterofcharger(canbeswitchedby
buttonofpageuporpagedown).
Theinterfaceofchargerstatewilldisplay:operatingmodeofcharger,chargertemperature,
positive/negativechargervoltage,andpositive/negativechargercurrent.
-
8/13/2019 Usermanual-11295075930
31/66
31
Figure3.23InterfaceofChargerState
Itcanswitchtointerfaceofchargerparameterbypressingbuttonofpageupordown,andthefollowinginformationwillbedisplayed:floatchargevoltage,evenchargevoltage,temperature
compensationsetting,positive/negativechargingspeed,andmaximumpositive/negativecharging
current.
Figure3.24InterfaceofChargerParameter
3.6.4Enquiryofbatteryinformation
Clickiconofbatteryinmaininterfacetoenterintointerfaceofbatteryparameter.Itwilldisplay:
piecesandgroupsofbattery,connectionstate,batteryvoltage,batterytemperature,batteryremain
time,batteryremaincapability,batterytemperature,timeofnextselftest.
-
8/13/2019 Usermanual-11295075930
32/66
32
Figure3.25DisplayofInterfaceofBatteryparameter
3.6.5Enquiryofcurrentwarn
ClickiconofWARNinmaininterfacetopopcurrentwarninginformation.Itcanswitchthe
warninterfacebetweenpowermoduleandchargerbybuttonofpageupandpagedown.
Figure3.26WarnInterface
3.6.6Enquiryofhistory
ClickiconofHISTORYinmaininterfacetopoptheinterfaceofUPShistory.Itcontains:FAULT,
WARNING,ATATUS,andOPERATE.
-
8/13/2019 Usermanual-11295075930
33/66
33
Figure3.27InterfaceofHistory
1.FAULT:
FAULTrecordsallfaultsoccurredduringoperationofUPS.
Figure3.28InterfaceofFault
2.WARNING
WARNINGrecordsreasonsforallwarnswhenwarnsoccurredforUPS.
-
8/13/2019 Usermanual-11295075930
34/66
34
Figure3.29InterfaceofWarning
FAULTandWARNINGcanrecord2100piecesatmostandtheearliestrecordswillbereplaced
bynewrecordifnumberofallrecordsexceeds2100.Allrecordsarelistedbyinvertedorderoftime.
3.OPERATE
OPERATErecordsalloperationsofUPStakenbyuser.
Figure3.30DisplayChartofInterfaceofOperate
4.STATUS
STATUSrecordsallworkingmodeofUPSunderdifferentperiods.
-
8/13/2019 Usermanual-11295075930
35/66
35
Figure3.31DisplayChartofInterfaceofStatus
OPERATEandSTATUScansave768piecesatmostandtheearliestrecordswillbereplacedby
newrecordifnumberofallrecordsexceeds768.Allrecordsarelistedbyinvertedorderoftime.
5.Enquiryrecord
Clickiconofenquiryrecordinfourinterfacesabovetopoptheinterfacesofrecordenquiry.
Entertherecordtime,itcaninquiryrecordsbeforeandaftertheenteredtime.
3.6.7Enquiryofcurrentinformation
Clickiconofsettinginmaininterfacetopopthesettinginterface.
Figure3.32SettingInterface
ClickiconofSETINFOtopopthecurrentsettinginterfaceofUPS.Informationcontainedin
theinterfaceincludes:cabinetNo.,statusofconvertermode,statusofcharger,statusofautostart,
testmode,andcontacttelephone.
-
8/13/2019 Usermanual-11295075930
36/66
36
Figure3.33DisplayofCurrentSettingInterface
Clickthepageuporpagedowntopopthewarrantyinterfacewhichcaninquirethewarrantyperiodofcomponentssuchasbatterytoremindtheusertoreplace.
Figure3.34DisplayofWarrantyInterface
3.6.8Enquiryofsysteminformation
Clickiconofsettinginmaininterfacetopopthesettinginterface.ClickiconofSYSINFOto
popthesysteminformationofthemachine,including:sequencenumber,model,softwareversion,
producer,telephone,andwebsite.
-
8/13/2019 Usermanual-11295075930
37/66
37
Figure3.35InterfaceofSystemInformation
3.7OperationsforUserConfiguration
Warn:operationforuserconfigurationisusedforsettingUPSparameters,and
nonprofessionalpersonalshallnottakeanysettingoperations.
ClickiconofUSERCONFinsettinginterfacetopopthepasswordinputinterfaceofuserset.
Figure3.36PasswordInputInterface
Entercorrectpassword(initialpasswordis666666)topoptheuserconfigurationinterface,
including:LANGUAGE,TIME,SELFTEST,PROTOCOL,PASSWORD,CALIB,andPHONE.
-
8/13/2019 Usermanual-11295075930
38/66
38
Figure3.37UserConfigurationInterface
3.7.1Languageset
LCDdisplayscreencanprovidethelanguageofEnglish.
Figure3.38LanguageSetInterface
3.7.2Timeset
ClickiconofTIMESETinusersetinterfacetoenterintotimesetinterface.Itcanchangethe
displayedtimeofUPSbyenteringcurrenttime.
-
8/13/2019 Usermanual-11295075930
39/66
39
Figure3.39TimeSetInterface
3.7.3Autoselftestset
ClickiconofSELFTESTinusersetinterfacetopoptheselftestsetinterface.
Itsdisplayisshowninfigure3.40,autoselftestinterfaceincludes:onandoffofselftest,run
cycleofselftest,anddurationofselftestforeverytime.
Figure3.40SelftestSet
Selectproperselftestdurationandtimebydemand.
3.7.4ProtocolSet
ClickiconofPROTOCOLinusersetinterfacetopoptheprotocolsetinterface.
-
8/13/2019 Usermanual-11295075930
40/66
40
Figure3.41ProtocolSetInterface
Therearetwooptionalcommunicationports,RS232andRS485.
ClickiconofRS232,andthencommunicationportsetinterfacewillbepopped.
Figure3.42CommunicationPortSetInterface
Portpropertyshallbesetbydemand.
3.7.5Password
set
ClickiconofPASSWORDinusersetinterfacetopopthepasswordsetinterface.
-
8/13/2019 Usermanual-11295075930
41/66
41
Figure3.43PasswordSetInterface
Thepasswordisrequiredwhenenteringuserconfigurationinterface.Enteroldpasswordandnewpasswordaccordingtorequirementtochangethepasswordof
enteringUserConfigurationInterface(initialpasswordis666666).
3.7.6Calibrate
Ifthetouchclickisnotsosensible,itcanrecoverthesensitivityoftouchscreenthrough
CALIBRATE.
ClickiconofCALIBRATEinsetinterfacetopopthecalibrateinterfaceoftouchscreen.Click
specifiedsiteaccordingtoorder,andthenthesensitivityoftouchscreenwillberecovered.
Figure3.44CalibrateInterfaceofTouchScreen
Note:objectusedtoclickthetouchscreenshallnotbetoosharpwhencalibrating,otherwise
itwilldamagethescreen.
3.7.7Telephoneset
ItcanchangethecontacttelephoneofagencybyTELSET.
-
8/13/2019 Usermanual-11295075930
42/66
42
Figure3.45Telephonesetinterface
3.7.8Muteoff
Clickiconofbatteryselftestandmuteoffinmaininterfacetopopinterfaceofbatteryselftest
andmuteoff.ClickMUTOFFinselftestinterfacetomutethewarningsound.
Figure3.46InterfaceofSelftestandMuteoff
3.7.9 Advanced setting
Note:
It
is
forbidden
to
enter
the
advanced
setting
interface
without
the
allowance
of
the
Customerservice,otherwisegreatdamagemayoccur.
ClicktheiconofADVANCEDinsettinginterfacetopopthepasswordinputinterface.
-
8/13/2019 Usermanual-11295075930
43/66
43
Figure3.47Passwordinputinterface
Entercorrectpassword(initialpasswordis19841219)topoptheadvancedsettinginterface.
Figure3.48Advancedsettinginterface
AdvancedsettingincludeMODELCHGCONFSYSCONFWARRANTYOPENSET
OTHERSET COMDATAandOUTCOEF.
1)MODELClicktheiconofMODELtopopthemodelsettinginterface.
-
8/13/2019 Usermanual-11295075930
44/66
44
Figure3.49Advancedsettinginterface
RUNMODE:tochoosetheworkingmodeuserneeded,singleorparallel. INTYPE:tochoosetheinputtypebytheconditionuseroffered,ifthemainpowerand
bypassarethesameACsource,choosesingle,ifnotchoosedouble.
CABNUM:iftheuserwanttobuildaparallelsystem,thecabinetsshouldbesetthenumberfrom1to6,iftheuserjustwantasingleUPS,thenumbershouldbesetas1.
OUTTYPE:wecansettheoutputtypeas3/3(3phaseinputand3phaseoutput)or3/1(3phaseinputand1phaseoutput).
UPSS/N:thisnumberistheserial number and forbiddenbeingchanged.2. CHGCONFClicktheiconofMODELtopopthemodelsettinginterface.
Wecanconfigurethechargerparameterandthebatteryparameterinthisinterface.
Figure3.50Chargerconfigureinterface
CHGSTATE: ifthisoptionissetasopen,thechargerisallowedtostart,otherwisethechargercannotstart.
TEMPCMP:thisfunctionhasnotopenyet. BATNUM:forstandardmachine,thenumbershouldbesetas16,forlongbackupmachine,
thenumberiscounttothemountofbatteriesuseroffered.
BATGROUP:thisparameterrefertothenumberofbatterygroups. BATCAPACITY:itshouldmatchthebatterycapacityuseroffered. CHGRATE:chargercurrent=chargerrate*batterygroups*batterycapacity.
-
8/13/2019 Usermanual-11295075930
45/66
45
SYSCONFClicktheiconofSYSCONF topopthesystemconfigureinterface.
Figure3.51Systemconfigure
1)CONVERT:tostartthefrequencyconvertermodeornot.
2)AUTOSTART:whenitisopen,theUPSwillstartautomaticallywhenthemainpowerresupply
aftertheUPSshutdowninbatterymode.
3) OUTFREQ:tosettheoutputfrequency,itcanbesetas50Hzor60Hz.
4) OUTVOLT:tosettheoutputvoltage.
5) BYPVOLT:tosettherangeofbypassvoltage, ifthebypasspowervoltage isbeyondit,UPS
willbeforbiddentostartbypassmode.
6) BYPFREQ:tosettherangeofbypassfrequency,ifthebypasspowerfrequencyisamongit,
theoutputfrequencywilljustfollowthebypassfrequency,ifnot,theoutputfrequencywillbe50Hz
or60Hz.
4 WARRANTY
ClicktheiconofWARRANTY topopthewarrantyinterface.
Figure3.52Warrantyinterface
ClicktheBAT orCAP tothewarrantysettinginterface.
-
8/13/2019 Usermanual-11295075930
46/66
46
Figure3.53BATwarrantyinterface
Theninputthetimewhenthebattery(capacitance)isreplacedandthelifeofthebattery(capacitance),theUPSwillwarnyouifthebattery(capacitance)isuptothewarrantydate.
WhenstartingtheUPSfirsttime,updatetheinstalltimeofthebatteryandcapacitance.
5 OPENSET
ClicktheiconofOPENSETtopoptheopensetinterface.
Figure3.54Opensetinterface
1)OPENPWD:ifitisopen,theuserneedinputthepasswordwhenstartingtheUPSnexttime,
aftertheUPSisstarted,thissetwillturntocloseautomatically.
2)LOCKPWD:ifitisopen,nopasswordsisneededtointerviewanyinterface.
3)BYPENA:ifitisopen,bypassmodecannotbestarted.
6 OTHERSET
ClicktheiconofOTHERSETtopoptheothersetinterface.
-
8/13/2019 Usermanual-11295075930
47/66
47
Figure3.55Othersetinterface
2. DEFAULT:restorethefactorysetting.3. FIRMWARE:toupdatetheSoftware.4. CLRLOG:clearhistory.7 COMDATA
ClicktheiconofCOMDATAtopopthecomdatainterface.
Figure3.56Comdatainterface
ThesecondrowistheworkingmodeoftheUPS,1meansstandbymode,2meansbypass
mode,3meansmainpowermode,4meansbatterymode.
TheforthrowistheBUSvoltageoftheBUSline,whentheUPSworksnormally,theBUSline
shouldbe360V.
ThefifthrowistheinvertervoltageoftheUPS.
Thesixthrowistheversionofthepowermodule
8 OUTCONF
ClicktheiconofOUTCONFtopoptheoutputparameterinterface.
-
8/13/2019 Usermanual-11295075930
48/66
48
Figure57Parametersetinterface
Clickthemoduleneededtobeadjustedtopoptheparameterinterface
1)INVVOLTSET:toadjusttheoutputvoltage.2)OUTVOLTSET:toadjustthedigitalwhichisdisplayedintheoutputinterface(chapter3.6.2)
oftheLCDscreen.
-
8/13/2019 Usermanual-11295075930
49/66
49
Chapter4InstallationandOperationofParalleledMachine
Themachinesupportsparalleledmachineextendedoperationwithmaximumextendednumber
ofmachinesis6andmaximumextendedpoweris360KVA.
4.1InstallationofParalleledSystem
1.Connectthemainpowerinput,bypassinput,outputandbatteryofUPSwhichisreadyfor
parallelaccordingtofigure4.1,andthenconnecttothemainpower,bypass,battery(onlyconnect
thebatteryinparallelforstandardmachine)andload.
Figure4.1ConnectionChartofParalleledMachines
2.Asshowninfigure4.2,connecttheparalleledportsofcommunicationportsforUPSreadyfor
parallelwithparallelwire,anditcanparallel6machinesatmost.
Figure4.2CommunicationConnectionChartofParalleledMachines
Note:
-
8/13/2019 Usermanual-11295075930
50/66
50
1.AlltheparalleledUPSshouldsharethesamebatteries,bypassandmainpower.Thesamephaseoftheoutputshouldbeconnectedinparallel.Otherwisegreatdamagemayoccur.
2.Itneedstodetectwhetherthewiringiscorrectornotafterparallelofoutput,bypass,battery
and
load
is
finished.
3.Lengthdifferenceofallthesinglemachineoutputlinesmustbelessthan10m.
4.2On/OffofParalleledMachines
4.2.1Parallelon/offofparalleledmachines
Setthecabinetsnumberfrom1 n(n6)inmodelsettinginterface(asshowninchapter3.7.9).
Closeallinputbreakers,bypassbreakers,batterybreakersandoutputbreakersofparalleled
machines,anditsmaininterfaceisshownasfigure4.3:
Figure4.3MainInterfaceofParalleledMachines
ClickiconofOn/OfftopoptheOn/Offinterface.
Figure4.4On/OffInterfaceofParalleledMachines
ClickSYSTEMinOn/Offinterfacetotakeon/offoperationofparalleledmachines(samewith
on/offoperationofsinglemachineinchapter3).
-
8/13/2019 Usermanual-11295075930
51/66
51
Figure4.5On/OffInterface
Note:all
breakers
shall
be
closed
when
power
on
or
power
off
the
paralleled
machines.
4.2.2Singleon/offofparalleledmachines
ClickiconofOn/OfftopoptheOn/Offinterface,asshownbelow:
Figure4.6On/OffInterfaceofParalleledMachines
SelectUPSn(n6)foron/offoperationtoenterintotheOn/OffinterfaceofUPS.
Takeon/offoperation(samewithon/offoperationofsinglemachineinchapter3).
4.3EnquireOperationofParalleledSystem
4.3.1Informationenquireofsinglemachineforparalleledsystem
ClickUPS n(n6)inmaininterfacetoenterintothesubordinateinterfaceofparalleled
system.
-
8/13/2019 Usermanual-11295075930
52/66
52
Figure4.7InformationInterfaceofSingleMachine
Thisinterfacecanenquiretheinformationoninputandoutputbatteryandchargerofthissinglemachine.
4.3.2Informationenquireofwholeunitforparalleledsystem
Clickrelatediconinmaininterfacetotaketheenquireoperation(samewiththatinchapter3).
-
8/13/2019 Usermanual-11295075930
53/66
53
Chapter5:
UPS
Repairing
and
Maintenance
5.1UPSRepairingandMaintenance
5.1.1PowerandfeaturesofloadshallbeconsideredwhenusingUPS
RatedoutputpowerofUPSisthekeyparametertoexpresshowmuchpowerloadtheproduct
candrive, it changes alongwith alteration of load power factor, for example, 1 KVAUPSmaybe
cannotdrive1KVAload.UPSshallnotbeunderfullloadconditioninordertoprolongworkinglifeof
UPS.Loadcapabilityof standbyUPS shallbe6070 of ratedpower,and thatofonlineUPS
shallbe7080 ofratedpower.Atthesametime,theUPSshallnotworkunderoverunder
loadingconditionforalongtime.
5.1.2EnsureinductionstrokeprotectionofUPS
Lightening stroke is the natural enemy of all electrical equipments, so it must ensure the
effective shielding and groundprotectionofUPS against lightening stroke. Lightening strokemay
causeinductivehighpotentialpulseduetoelectromagneticinduction.Thehighpotentialpulsemay
enter into the UPS along with power line or communication line, while there are so many
microelectronicdevices suchasCMOS integratedcircuitmodulesandCPUused forcontrol in the
UPSwhichareverysensitivetoelectromagneticpulseoflightening,therefore,thedevicesarevery
easytobedamaged.AlthoughourUPShaseffectiveshieldingandgoodprotectiongroundmeasure,
user still needs to adopt lightening protection and overvoltage protection for power line and
communicationline(suchasremotemonitoringsingleline).
5.1.3Notesforusing,repairingandmaintenance
ItmustobeytheproductintroductionwhenusingUPS.Relatedstipulationsinusingmanualcanensureallfiringlines,zerolines,andearthlinesmeetrequirements,sousershallnotchangeits
orderwithoutallowance.
Anyoperation shall strictly complywith correctorderofpoweron andoff. It shall avoidexcessive fluctuationofvoltageoutputofUPScausedbysudden increasingorreducingof loadso
thattheUPScannotworkinnormal.
It isstrictlyforbiddentopoweronandofftheUPSfrequently.Itrequiresfor30saftertheUPSispoweredoffandbeforestartingitagain,otherwise,faultmayoccurredforUPS. Itisforbiddentooperateunderoverload.MaximumstartingloadofUPSshallbecontrolledwithin80%,andtheinvertertubemaybedamagedunder invertercondition ifit isoperatedunder
overloadcondition.Experienceproves that thebestoperationmode is tocontrol the loadwithin
30~60%ofratedoutputpowerformostUPSpowers.
Discharging requirement of battery: in general, the UPS is equipped with protectionmeasures for discharging of battery, but the battery will recover to certain voltage after it is
discharged so that the protection is powered off, and it is not allowed to restart the machine,
otherwise, itmaycauseoverdischargingofbattery.Thebattery shallbeusednormallyafter it is
recharged.
FornewboughtUPS (or forUPSstored fora longtime), itonlycanbeoperatedafterthebatteryischarged.Otherwise,thestandbytimewillnotbeensured.
-
8/13/2019 Usermanual-11295075930
54/66
54
ForUPSwithoutpoweroff for a long time, itsbattery shallbedischarged forevery3~6monthsandthenrechargedagain.Itcanprolongtheworkinglifeofbatterybythisway.
For UPS stored for a long time, it shall be started and charged for every 3~6 months,otherwise,itmaydamagethehostandbatteryofUPS. ItshallmaintaintheUPSperiodically.Cleandustinsidethemachine,measurethevoltageofbatterygroup,checkrunningoffans,andinspectandadjustsystemparametersofUPS.
5.1.4Batterymanagement
This system allows the charging system to bewith high liability andwithouthigh frequency
clutterwhichcanavoideffectofhighfrequencywavetobatterylife;avoidoverheatofbatterywhen
charging,andprolongworkinglifeofbattery.
User can set the battery parameter by monitoring display screen (battery management
parametermustbesetbyprofessionalpersonal,pleasenotifythecustomerservicepersonalifuser
needs to change theseparameters),and the system can take intelligentmanagement forbattery
accordingtousersetandactualstatusofbatterygroup.
Chargemodeofthisseriesofproductssystemisthreestagecharge:
Stage1:recharge90%capabilityofbattery
Chargewithequalizingchargingvoltageandmaximumchargingcurrent;
Stage2:rechargethebalance10%capabilityofbattery
Turntostage2toequalizingchargefor1minuteandfloatingchargefor1minutewhenvoltage
reachesto13.85Vofeverybattery.
Stage3:Maintainbatterycapability
Itwillswitchtostage3afteritcontinuesfor360cycleinstage2andchargethebatterywith
floatingchargesotatthebatteryquantitycanbemaintainedmorethan99%.
Batterygroupof900II1060KseriesproductissharedbyallmodulesinUPS(includingcharging
and discharging). It can use one group of battery or several groups of batteries to increase the
standbytimeofsystemaccordingtousersrequirement.
Tips: itmust takeoffmetalobjects suchas ringandwatchbefore replacing thebattery,use
screwdriverwith insulatedhandle,donotputany toolorothermetalobjecton thebattery. It is
normalphenomenontoappearsmallsparkatjointwhenconnectingthebattery,butitwillnotcause
anyharmtopersonalsafetyandUPS.Donotcauseshortcircuitorreverseconnectiononpositive
andnegativeofbattery.
5.2Troubleshooting
FaultsofUPScanbeknownbyinquiringhistoryrecordsofUPS,andcommonproblemsduring
operationofUPScanbesolvedbycontrastingtable4.1.
Table5.1Fault/WarnRemoval
ProblemType Fault/Warning Solution
Battery Overcharged Power off the charger and contact
customerservicepersonal.
Charger FailPower off the charger and contact
customerservicepersonal
Warningof
charger
Battery DisconnectedCheckwhetherchargerisstartedor
not
-
8/13/2019 Usermanual-11295075930
55/66
55
Bat Num setting errorContactcustomerservicepersonal
toresetthebatterypiece
Over Temperature Unnecessarytosolveit
ChargeVolt setting error
ChargeCurr setting error
Contactcustomerservicepersonal
tochangetheset.
Charger Fanlock
Pleasecontactcustomerservice
personalifthechargerfanis
damaged
Buck Soft Start FailPoweroffthechargerandcontact
customerservicepersonal.
Input Fuse Fail
Output Fuse Fail
Contactcustomerservicepersonal
toreplacethefuse
Charger ShortCircuit Poweroffthechargerandcontactcustomerservicepersonal
Faultofcharger
Battery ReverseCheck whether the battery
connectioniscorrectandcorrectit
Bus Volt High
Bus Volt Low
Bus Imbalance
1. Check whether threephase
normalpowerisinbalance.
2.Checkwhetherthefluctuationof
threephasenormalpowerisin
normal.
Bus Short circuit Contactcustomerservicepersonal
Bus Softstart Fail
Inv Softstart Fail
Cutoff
the
input
breaker,
and
start
themachineafter30s.Please
contactthecustomerservice
personalifproblemstillexists.
Inverter Volt High
Inverter Volt Low Contact the customer service
personal
R phase Out Short
S phase Out Short
T phase Out Short
RS phase Out Short
ST phase Out Short
TR phase Out Short
1. Check whether the output
connectionisshortcircuitornot.
2.Checkwhethertheloadisshort
circuitornot.
R Reactive Abnormal
S Reactive Abnormal
UPSfault
T Reactive Abnormal
Contactthecustomerservice
personal
-
8/13/2019 Usermanual-11295075930
56/66
56
Overload Fail
1.Poweroffsecondaryload
2. Reallocate the load so that
outputs of three phases are
balance.
3.CutoffUPSinputbreakerfor30s,
thenstartagain.
Overtemp Fault
Ensure environmental temperature
iswithinworkingrangeofUPS.Cut
off theUPS for30s, and then start
again.
Power Set Fault
Inverter Fault
Relay Stick Death
Line SCR Fault
Contactthecustomerservice
personal
Can Bus FaultCheckwhetherthecommunication
lineisconnectedcorrectly
Bypass wiring error
Checkwhetherthebypassphase
sequenceconnectionofcabinetis
normalornot
Power Set Fault
Total Reactive Fault
Contactthecustomerservice
personal
Id Error
1.Checkwhethersetofdialswitch
inbackofmoduleis1~2.
2.Checkwhethersetofdialcodesinbackofmoduleisconflict.
BypassPhaseError
Line Phase Error
Bypass Loss
1.Checkwhethertheinputpoweris
normal.
2.Checkwhetherthethreephase
inputlinesareconnectedcorrectly.
Bypass Freq AbnormalCheck whether the input power is
normal.
N Line Loss
1.Checkwhetherthebackterminal
ofmoduleisnormal.
2. Check whether the terminalconnected cabinet and module is
normal.
Input CB OpenCheckwhetherthe inputbreaker is
closedornot.
Output CB OpenCheckwhether the output breaker
isclosedornot.
Output OvervoltPleasecontactthecustomerservice
personal.
Maint CB Cover OpenUnnecessary for treatment under
maintenancebypassmode
-
8/13/2019 Usermanual-11295075930
57/66
57
Maint CB Cover Open
1.Unnecessaryfortreatmentunder
maintenancebypassmode.
2.Checkwhetherthescrewof
maintenancecoverisfastenedornotunderotheroperationmode.
Battery Volt Low
1. Check whether the battery and
chargerarenormalornot.
2.Checkwhetherthebatteryset
matcheswithactualconfiguration.
3.Pleasedismantlethesecondary
loadassoonaspossibleifitisunder
batterymode.
Battery Open
1.Checkexternalbatterybreaker is
closedornot
2.Checkwhetherthebatteryis
connectedwell
Ovload Fail
UPS Over Current
UPS Over Load
1.Closethesecondaryload
2.Reallocatetheloadsothat
outputsofthreephasesare
balance.
Eeprom FailForbiddentopoweron,andcontact
thecustomerservicepersonal.
UPS Fan LockContactthecustomerservice
personalifitismodulefault.
Epo Active
ConfirmwhetherthebuttonofEPO
ispressedornot.Pleasecheckthe
screwinleft
side
ofmodule
is
fastenedornotifitisnotpressed.
Charger OfflineCheckwhetherthechargeris
mounted.
Can Fail
Comm Syn Sig Fail
Comm Syn Pulse Fail
Checkwhetherthecommunication
lineisconnectedwellornot
Id Error
IDerrorofpowermodule
Checkwhetherthesetofdialswitch
inconnectingpanelin
correspondingmodulelocationof
cabinetiscorrectornot.
R phase PFC Fail
S phase PFC Fail
T phase PFC Fail
Bypass STS Open
Bypass STS Short
Contacttheconsumerservice
personal
-
8/13/2019 Usermanual-11295075930
58/66
58
5.3MaintenanceAssurance
Underconditionofcomplyingrulesofstorage,mounting,using,andoperation,wehaveliability
todebug,repairorchangeelementsandcomponentstimelyfreeofchargeiftheproductis
damagedduetopoorqualityorimproperoptionorcannotoperatenormallywithinthreeyearssince
itisdelivered;wehaveresponsibilitytoprovidepaidlifemaintenancefortheproductifitisoutof
thewarrantyperiod.
Servicecommitmentofourcompanyis:warrantedforthreeyearsandmaintainedforalllife.
Thefollowingcasesarenotincludedinwarrantyrange:
1.Artificialfault;
2.Outofwarrantyperiod;
3.Productwhoseproductionserialnumberischangedorlost;
4.Damageorlosscausedbyforcemajeureandexternalcauses;
5.DismantleorchangetheUPSwithoutauthority;
6.Breachoperation/applicationstipulationsofUPS;
7.Thebatteryisdischargeddeeplyordamagedbymanual.
5.4TechnicalSpecifications
Table5.2TechnicalSpecifications
Model 9010II 9015II 9020II 9030II 9040II 9060II
Nominalcapacity 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA
Input
Ratedinputvoltage 380Vac
Load50% 204~520Vac
50% load70% 242~520Vac
70% load100% 304~520Vac
Inputmode Threephasefivewiresystem
Inputpowerfactor 0.99
Totalharmonic
distortion(THDi)
3%
Ratedfrequency 50Hz/60Hzselfadoption
ACmainpowerinput 40~70Hz
Bypassvoltagerange 380Vac*(120%)Settable
Output
Outputpowerfactor 0.9
Ratedvoltage 380VacStabilizedvoltage
precision
1%
Dynamicvoltage
transientrange
5%(0100%loadfluctuation)
Totalharmonic
distortion(THDV)
1%(resistiveload);
3%(nonlinearload)
Outputvoltagedirect
currentcomponent
100mv
Outputcurrentpeak
factor
3:1
-
8/13/2019 Usermanual-11295075930
59/66
59
Model 9010II 9015II 9020II 9030II 9040II 9060II
Outputfrequency Mainpowermode:synchronouswithmainpower;batterymode:
50Hz/60Hz
Batterymode 50Hz/60Hz
Frequencytracking
rate
1Hz/s
Phaselockaccuracy 1
Inverteroverload
capability
100%150%,continuefor10s
Mainpowermode
Batterymode
0ms
Batterymode
Mainpowermode
0ms
System
Workingefficiencyof
unit
93%(50%load)
Batteryconfiguration 192V~240V(positive/negativebatterygroupwith16,17,18,19and20
piecesforeachgroupforoption,32pieces12V/7AHor12V/9AHare
equippedforstandardmachine,thebatteryspacecanallow64pieces
batteriesatmost)
Maximumcharging
current
12A 24A
Maximumparalleled
machines
6
Workingtemperature
range
0~40
Workingelevation
height
25A)classA
UPScabinetsize 600mm*800mm*1280mm
Weight(kg) 158 164 164 174 190 210
Color Black
Controlpanel 5.7inchmultifunctionalLCDtouchwidescreen
-
8/13/2019 Usermanual-11295075930
60/66
60
Model 9010II 9015II 9020II 9030II 9040II 9060II
Audiblealarm Alarmofbatterymode;warnwhenvoltageofbatteryistoolow;alarmof
fanfault,etc.
Port USB,RS232,RS485anddrycontact(standardequipped)
Optionalelement SNMPcard,Paralleledmachinecard
-
8/13/2019 Usermanual-11295075930
61/66
61
Appendix
1:
Lamp
Signal
Reference
List
Mode Fault/Warning StatusofLED Statusofbuzzer
Phase sequence is error,
and mainpowerbypass is
abnormal
Thefaultlight
twinklesonce2sand
lastsfor1/4s
Buzzonce2sand
lastfor1/4s
Disconnectionofbattery Thefaultlight
twinklesonce4sand
lastsfor1/4s
Buzzonce2sand
lastfor1/4s
Standbymode
Nofault Allisoff Nosound
Somemodule isunderfault
mode
Thebypasslightison,
faultlighttwinkles
once1sandlastsfor1/4s
Buzzonce1sand
lastfor1/4s
Chargerisnotstarted Thebypasslightison,
faultlighttwinkles
once8sandlastsfor
1/4s
Buzzonce8sand
lastfor1/4s
Overload Thebypasslightison,
faultlighttwinkles
once2sandlastsfor
1/4s
Buzzonce2sand
lastfor1/4s
Phasesequenceiserror Thefaultlight
twinklesonce2sand
lastsfor1/4s
Buzzonce2sand
lastfor1/4s
Disconnectionofbattery Thebypasslightison,
faultlighttwinkles
once4sandlastsfor
1/4s
Buzzonce4sand
lastfor1/4s
Bypassisnormal Thebypasslightison,
faultlighttwinkles
once4sandlastsfor
1/4s
Buzzonce4sand
lastfor1/4s
Bypassmode
Nootherfault Thebypasslightison,
faultlighttwinkles
once2mandlastsfor
1/4s
Buzzonce2sand
lastfor1/4s
Somemodule isunderfault
mode
Thenormallightison,
faultlighttwinkles
once1sandlastsfor
1/4s
Buzzonce1sand
lastfor1/4s
Chargerisnotstarted Thenormallightison,
faultlighttwinkles
once8sandlastsfor
1/4s
Buzzonce8sand
lastfor1/4sMainpower
mode
Overload Thenormallightison,
faultlighttwinkles
Buzzonce2sand
lastfor1/4s
-
8/13/2019 Usermanual-11295075930
62/66
62
once2sandlastsfor
1/4s
Disconnectionofbattery Thenormallightison,
faultlighttwinklesonce4sandlastsfor
1/4s
Buzzonce4sand
lastfor1/4s
Nootherfault Normallightison Nosound
Somemodule isunderfault
mode
Faultlightisonallthe
time
Buzzallthetime
Lowvoltageofbattery Battery light twinkles
once1s
Buzzonce1sand
lastfor1/4s
Overload Allisoff Buzzonce2sand
lastfor1/4s
Battery self
test
Othersarenormal Twinkle in turn for
every2s
Nosound
Bypass and output are
normal
Bypass light is on,
fault light isonallthe
time
BuzzallthetimeFaultmode
Bypassandoutputare
abnormal
Faultlightisonallthe
time
Buzzallthetime
Somemodule isunderfault
mode
Thenormallightison,
faultlighttwinkles
once1mandlastsfor
1/4s
Buzzonce1sand
lastfor1/4sFrequency
conversion
mode
Nofault Thenormallightison Nosound
Poweroff Allisoff Nosound
Communication is
abnormal
Allisoff Nosound
-
8/13/2019 Usermanual-11295075930
63/66
63
Appendix2:
Port
of
Communication
Interface
Thereareseveralcommunicationportsfor900II1060KVAsystem,asshowninFigure1:
Figure1Chartof900II1060KCommunicationPort
1.SNMPNetworkCardPort(optionalfitting)
TheLANportcommunicationneedstobesetas:
Connectthecomputerandsystemwithnetworkcable.Itcanusetwistedpairnetworkcableto
connectthecomputerdirectlyorusedirectnetworkcabletoconnectthecomputerthrough
switchboard.
2.RS232Port
Itsmaximumtransmissionrangeis50mwhenthebaudrateis9600.
RS232interfacedefinition(othersarenotconnected):
Stitch 2 3 5
Definition RXD TXD GND
3.RS485Port
Itsmaximumtransmissionrangeis500mwhenthebaudrateis9600.
RS485providesdifferentportsfortwokindsofconnectingmodes,oneisRJ45networkcable
port,andtheotherisdoublepinport.
RJ45networkport(othersarenotconnected):
-
8/13/2019 Usermanual-11295075930
64/66
64
Stitch 3 5
Definition A B
Doublepinport:
Stitch 1 2
Definition A B
4.USBPort
TheUSBportisspecialportforUPSmart2000Imonitoringsoftware.
5.InspectionPortofBatteryTemperature
Thechargermodulecancollectbatterytemperatureatanytimetoprovidetemperature
compensationthroughinspectionportofbatterytemperature.
6.PassiveOutputDryContact
900II1060KUPS isequippedwithadrycontactcardwhichcontains7groupsof independent
passiveoutputdrycontactswiththreeconnectingterminalsforeverydrycontact,andfrom leftto
right which are: normally closed terminal, common terminal, and normally open terminal. The
passivedrycontactiscontrolledbyrelay,andthecommonterminalandnormallyclosedterminalof
relaywillbeconnectedwhendefinedstatusofdrycontact isfalse;therelaywillstartoperationat
oncewhendefinedstatusofdrycontactistrue,andthecommonterminalwillbedisconnectedwith
normallyclosedterminalofrelay,andbeconnectedwithnormallyopenterminal.Usercanselectto
connectthenormallyopenterminalornormallyclosedterminalaccordingtoactualdemand.
Identifier Meaning
INV Inverteroutput
LINELOSS Mainpowerisabnormal
OVERLOAD Overloadofoutput
BYPASS Bypassoutput
FAULT Systemfault
BAT.LOW Warningofbatterylowvoltage
ALARM Systemalarm
-
8/13/2019 Usermanual-11295075930
65/66
65
Appendix3:
Dial
Switch
Set
of
Module
and
Charger
1.DialSetofAddressforModuleInputPowerConnectorDependingonthepowersegment,theDIPswitchintheinputpowerconnectorcanbesetas
follows:
Dialswitch(0meansOFFand1meansON)
1 2 3 4
10KVA 1 0 0 0
15KVA 1 0 0 0
20KVA 1 0 0 0
30KVA 1 0 0 0
40KVAupper
partmodule
1 0 0 0
40KVAlower
partmodule
0 1 0 0
60KVAupper
partmodule
1 0 0 0
60KVAlower
partmodule
0 1 0 0
Figure2DialSetofAddress
2.DialSetofHardwareProtectionforChargerSetthesetdialswitchofbatterypiecesofcommunicationportinterfacesothatitcanbethe
samewithactualbatterypiecestoprotectthebattery.
Dialswitchisprotectedbyacover,soitshalltakeawaythecoverbeforeadjustthebattery
pieceofdialswitch.
Dialswitchsetsforallbatterypiecesare:
Dialswitch(0meansOFFand1meansON)
1 2 3 4
20piecesof
batteries
0 0 0 0
19piecesof
batteries
1 0 0 0
18piecesof
batteries
1 1 0 0
17piecesof
batteries
1 1 1 0
-
8/13/2019 Usermanual-11295075930
66/66
16piecesof
batteries
1 1 1 1
Forexample,figure3refertothesetof16piecesofbatteries.
Figure3Thesetof16piecesofbatteries