Page 1: User manual Easy Parameter setting and Programming …files.danfoss.com/technicalinfo/dila/01/DKRCE.PS.RL0.A3.02.pdf · Easy Parameter setting and Programming of your ... The following

User manual

Easy Parameter setting and Programming of your product KoolProg®

http://koolprog.danfoss.com

Page 2: User manual Easy Parameter setting and Programming …files.danfoss.com/technicalinfo/dila/01/DKRCE.PS.RL0.A3.02.pdf · Easy Parameter setting and Programming of your ... The following

2 User manual DKRCE.PS.RL0.A3.02 © Danfoss 5/2017 KoolProg® Software tool

1.0 Downloading .exe file

The following instructions will guide you through the installation and first time usage of KoolProg®, which supports setting parameters and programming of ETC 1H, ERC 11X, ERC 21X, EKE 1X.

Download KoolProgSetup.exe file from the location: http://koolprog.danfoss.com

3.0 Software installations

2.0 System requirements This software is intended for a single user.

OS Win 7 Enterprise service pack 1, Win 8, Win 10. 32 bit and 64 bit (Recommended)

RAM 8 GB RAM minimum

HD Space 200 GB and 250 GB (Recommended)

Required software MS Office 2010 and above

Interface USB 3.0 (Recommended)

Macintosh and Windows server versions and installation on a network file server are not supported.

• Double click on the KoolProg® setup icon Run the installation wizard and follow the onscreen instructions to complete the KoolProg® installation.

• During installation If you encounter a "Security warning", please click on "Install this driver software anyway".

• After successful Installation Double Click on the KoolProg® icon on the desktop to launch the KoolProg® application.

• Set Preferences (all these settings can be changed later. See page 5.) Set Language, units, files saving location, CAN Baudrate and password.

• On completion of above steps KoolProg® home page opens.

0.0 Introduction

®

KoolProg® Registration and DownloadPlease fill out the form below. Once you click "Download" the link to the software will be displayed. (.ZIP file size approx. 260 MB)

Page 3: User manual Easy Parameter setting and Programming …files.danfoss.com/technicalinfo/dila/01/DKRCE.PS.RL0.A3.02.pdf · Easy Parameter setting and Programming of your ... The following

KoolProg® Software tool User manual DKRCE.PS.RL0.A3.02 © Danfoss 5/2017 3

Dan

foss

80G16

3.01

Dan

foss

80G16

4.01

Dan

foss

80G16

5.01

Dan

foss

80G16

2.01

12 Vdc 24 VacCAN RS485

D+ D-R H L GND GND+-

105

72 31

Dan

foss

80G80

77.01

1. Connect USB cable to the USB port of PC2. Connect the controller. See below.

CAUTION:Please ensure that only one controller is connected at any time.

4.0 Connections

Interface cable for ERC 10X and 11X

Interface cable for ERC 21X.

Interface cable for ETC

Gateway box

USB A -USB B cable

PC connection:USB mini -USB A

To PC

fig. afig. b

ETC 1H can be connected in two ways.• If controller is not powered, connect both cable

connectors corresponding to inputs 1.1 and 3.1 accordingly, (refer fig. a).

• If controller is powered only one connection is required to be connected to input 1.1 (refer fig. b).

Connect corresponding cable from gateway to ERC 21x PV 7 and later.

Connect the corresponding cable from gateway to “di” port of ERC 11X

4.3 ETC 1H connection

4.2 ERC 21X connection

4.1 ERC 11X connection

Connection for EKE = Interface type MMIMYK (Code No. 080G0073)

Connection for ERC and ETC = Gateway box (Code No. 080G9711)

EKE connection:RJ11-RJ11

1. Connect USB cable to the USB port of PC2. Connect the controller. See next page.

Page 4: User manual Easy Parameter setting and Programming …files.danfoss.com/technicalinfo/dila/01/DKRCE.PS.RL0.A3.02.pdf · Easy Parameter setting and Programming of your ... The following

4 User manual DKRCE.PS.RL0.A3.02 © Danfoss 5/2017 KoolProg® Software tool

EKE 1x must be connected to the PC by a type MMIMYK interface programmable controller unit.

4.4 EKE 1X connection

Power24 V

Power12 V D.C.

Page 5: User manual Easy Parameter setting and Programming …files.danfoss.com/technicalinfo/dila/01/DKRCE.PS.RL0.A3.02.pdf · Easy Parameter setting and Programming of your ... The following

KoolProg® Software tool User manual DKRCE.PS.RL0.A3.02 © Danfoss 5/2017 5

This is where you can choose the settings that will later be transmitted to a controller. Refer to Page 6 for more information.

Select the units you prefer to work with:°C and bar (Metric) or°F and PSIG (Imperial).

Clicking here lets you open this user manual and view it on the screen.

This is where you can select a file to be transmitted to a controller. Refer to Page 8 for more information.

This is where you can connect to a controller that is in use.You can modify the settings or run the Trend feature to see a line chart of selected measurements.Refer to Page 9 for more information.

The program’s features

5.0 Starting the Program

If the program is to be operated by several individuals, it is possible to specify two different access levels: one with a password and one without a password.Users with a password have access to all features.Users without a password have limited access and may only be able to use the Copy to controller feature.

Click here for the 'Preferences' window.

Page 6: User manual Easy Parameter setting and Programming …files.danfoss.com/technicalinfo/dila/01/DKRCE.PS.RL0.A3.02.pdf · Easy Parameter setting and Programming of your ... The following

6 User manual DKRCE.PS.RL0.A3.02 © Danfoss 5/2017 KoolProg® Software tool

This feature allows you to configure parameter settings for your application. Click one of the icons in the right column to create or open a project.You can see projects you have already created under "Recent Projects."

"Open" command lets you to open an existing project. Once the command is clicked a window will appear above.

All projects are stored here in the folder: “KoolProg/Configurations” by default. You can change the default file saving location in "Preferences."You can also put a project that you have received from another source in this folder. Once you have copied it into the folder, you can open it with the “Open” command.

6.0 Set parameters

New

Upload from controller

Open

This is where you can create new project by selecting:- Controller type- Part number- PV number- SW versionOnce you have selected a file, you need to name the project.Click 'Next' to proceed and set parameters.

'Upload from controller' lets you to view and modify parameter settings of the connected controller. Once the connection is established, the controller picture is displayed in the window and the parameters are listed on the page. Now, you are ready to work live with the parameters of the connected controller (as explained in the next section of this manual).

Page 7: User manual Easy Parameter setting and Programming …files.danfoss.com/technicalinfo/dila/01/DKRCE.PS.RL0.A3.02.pdf · Easy Parameter setting and Programming of your ... The following

KoolProg® Software tool User manual DKRCE.PS.RL0.A3.02 © Danfoss 5/2017 7

FavouritesYou can select a number of parameters by ticking the ones you want in the “stars” column.

Afterwards they will be visible in the “Favourites” folder (first column at the top).

View moreThis command gives the complete technical description of the controller.

Dot SymbolA dot symbol will appear in front of a value if it has been modified and is no longer identical to its factory setting.

Hint - Search Function You can search for and display a specific parameter with the search function.Type in the first few letters of the name of the parameter and click “Search”.

Factory resetThis command will reset the controller values to default factory settings.

Arrow Left/RightBy clicking the arrow, you can hide the description of the selected parameters.Clicking it again causes the description to reappear.

Arrow Up/DownBy clicking the arrow, you can hide the two photos and display more parameters in the window.Clicking it again causes the photos to reappear.

Headline Home: The "Home" Command will take you back to the Start Menu. Open: The "Open" command lets you open an existing project. Save: The "Save" command lets you save all the changes in the active project. Save as: The "Save as" Command allows you to save your controller settings as a new project. Arrow down: This command copies the project settings to the connected controller. Arrow up: This command retrieves all the settings of the connected controller and displays them in the current project.

Informational PhotosThe project’s data is shown on the left.The controller the program is connected to is shown on the right.

If the data are identical, these can then be transmitted to the controller.If they are not identical, then these cannot be transmitted. A warning message pops up.

Set parameters - continued

Info

I =Controllerinformation.

Read value field= Unsaved setting

Page 8: User manual Easy Parameter setting and Programming …files.danfoss.com/technicalinfo/dila/01/DKRCE.PS.RL0.A3.02.pdf · Easy Parameter setting and Programming of your ... The following

8 User manual DKRCE.PS.RL0.A3.02 © Danfoss 5/2017 KoolProg® Software tool

Select the project you want to program with the “BROWSE” command.

You can save a project in “Favorite Files” by clicking on "SET AS FAVOURITE" button. The project will be added to the list and can be easily assessed later.(Click on the trash icon to remove a project from the list).

7.0 Copy to controller

Once you have selected a project, the key details of selected file are displayed.

Multiple Controller ProgrammingIf you want to program multiple controllers with the same settings, use "Multiple Controller Programming."Set the number of controllers to be programmed, connect the controller and click “START” to program the file - wait for the data to be transferred.

Connect the next controller and click “START” again.

The key details of the project file are shown here.

The key details of the connected controller are shown here.

Counter reset to start position ("0" or "Set counter" value).

If the project file and the connected controller match, data from the project file will be transmitted to the controller when you click the “START” button.

The program checks whether data can be transmitted. If not, a warning message pops up.

Please ensure the connected controller’s details match with the selected project file.

Page 9: User manual Easy Parameter setting and Programming …files.danfoss.com/technicalinfo/dila/01/DKRCE.PS.RL0.A3.02.pdf · Easy Parameter setting and Programming of your ... The following

KoolProg® Software tool User manual DKRCE.PS.RL0.A3.02 © Danfoss 5/2017 9

8.0 Service This lets you monitor the real time operation of the controller while it is running.• You can monitor inputs and outputs.• You can display a line chart based on parameters you have selected.• You can configure settings directly in the controller.• You can store line charts and settings and then analyze them.

Arrow Up/DownClicking the arrow lets you hide the photo and the top block of information so you can display more parameters in the window.Clicking the arrow again makes them reappear.

OpenThis lets you view prior line charts you have made from collected data.

Save asThis lets you save a project file containing all of the controller’s settings.

Active AlarmsThis shows the active alarms at the current time.Description of the alarm appears on the right of the table when an alarm is selected.

The Trend FeatureIf you want to chart the trend for a measurement, you can select what you want to view from this table. Tick the box of any parameter you would like to include in the chart. You can select a maximum of 10 parameters.

Line ChartClick the “Line Chart” button to switch over to the trend view. You can begin charting any measurements you want in the trend view.

Page 10: User manual Easy Parameter setting and Programming …files.danfoss.com/technicalinfo/dila/01/DKRCE.PS.RL0.A3.02.pdf · Easy Parameter setting and Programming of your ... The following

10 User manual DKRCE.PS.RL0.A3.02 © Danfoss 5/2017 KoolProg® Software tool

You can start or stop data logging by clicking the corresponding buttons.

You can set the time interval for the time labels on the x-axis by modifying ‘Label.’

You can define the time period shown on the screen before the view refreshes by changing the Zoom Level.

You can change how often you want to record a value by changing the log interval.

The program only saves data if the “Save chart” box is checked. If you want to save the collected data in another file format, use the “Save As” command. This enables you to save data in either a .CSV or .PNG file format.After saving an image, the chart can be viewed later in selected file format.

You can change the duration for which the data has to be collected by changing the log period.

Trend Charts

You can stop a parameter from trending by unchecking the box in front of that parameter.

AD

AP-