ultrasonic flow meters expertise innovation service · 2015-09-19 · expertise innovation service....

15
Ultrasonic Flow Meters Expertise Innovation Service

Upload: others

Post on 03-Aug-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

UltrasonicFlow MetersExpertise InnovationService

Page 2: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing and mar-keting its own extensive range of products. Our complete range includes, portable and fixed flow meters for liquids and gases, open channel me-ters, clamp on heat meters, interface and pig detectors and gas level measurement systems (i.e. level measurement in gas storage caverns).Ultraflux’s focus on ultrasonic transit time flow measurement and ultrasonic instrumentation gives us the technical skill and experience to solve even the most demanding applications.

We supply our systems Worldwide: more than 50% of our products are exported. We have sub-sidiaries in Brazil and Thailand and a network of highly experienced partners.

Our fields of application

01. Flow measurement on old pipe (1868)02. Gas flow measurement with 5 chords 03. Flow measurement on irrigation channel

Get introduced to

Specialist in ultrasonicflow meters

Quality manufacturersince 1974

01

02

03

Page 3: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

As the world’s pioneer in ultrasonic flowmeters, it was Ul-traflux who developed the first instruments to be used in specific measurement applications by the major French groups. Since 1974, Ultraflux has kept on growing, conti-nually consolidating our original expertise and skills.This is what makes us, and our services, unique. One third of our workforce is made up of Engineers or Doctors. We place utmost importance on innovation, and this is backed up by a strict metrological approach and the results from our expe-rimental facilities. We are active across a huge range of in-dustries, from water and the environment to oil, chemistry, nuclear and hydroelectric… By combining a technological focus – ultrasonic flowmeters – and our multi-sector and multi-application skills, we convert our talents into a real growth engine for the company.In an effort to support this growth, Ultraflux moved to a new site in 2012. It gives us more space to build up our produc-tion facilities and install an even more effective research la-boratory.Lastly, we are continuing to strengthen our application engi-neering department in order to provide even more services to our customers, whether in terms of managing complex projects in collaboration with integrators or design offices, or in terms of technical support around our measuring points before, during and after installation.A complete understanding of processes and a metrological approach are now more than ever vehicles for progress in both industry and research.

This is our vision, and our commitment.

Jean-Olivier Schneider

01 & 02. Ultraflux headquarters in Éragny sur Oise — France03. Jean-Olivier Schneider, Ultraflux chairman & managing director

01

02

03

A word from the chairman

RIO BRASIL

ULTRAFLUxSUBSIDIARIES

BAngkOkThAILAnD

ULTRAFLUxhEADqUARTERS

ÉRAgny SUR OISE(30 kM FAR

FROM pARIS)

Page 4: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

Ultraflux ISO 9001 Quality certification Ultraflux ISO 14001 Environment certification

ISO certificatesQuality and environment

Quality and environmental responsibility are of para-mount importance to our company: we are certified to ISO 9001 since 1997 and ISO 14001 since 2009.

Page 5: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

ATEX certifications

Ultraflux ATEX certification – for an approved production quality assurance system

Ultraflux production quality assurance notification (page 2)

Ultraflux production quality assurance notification (page 1)

Our products are certified to ATEX since 2003.

Page 6: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

Leading innovation is of paramount importance to us. That is why one third of our workforce is made up of Engineers or Doctors. Our research laboratory is located in France (Éragny sur Oise), where we build tomorrow’s products.

R&D department

01. Fabrication of insertion probes 02. Use of a coiling machine to make custom cables 03 & 04. Calibration of a spool piece before installation 05. Assembly of a portable flow meter

Teams of experts in charge of all production and special projects matters.

Production and engineering departments

0201

03

04

05

01. Calibration bench (flow loop) 02. Computation of the impact of complex geometry on flow with CFD (Computational fluid dynamics) 03. Ultraflux 3D scanning ultrasonic immersion tank 04. Simulation of the ultrasonic wave propagation 05. Ultrasonic field measurement — All images by Ultraflux

05

03

04

02

01

Page 7: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

A team of specialists dedicated to set-up and reparation of material. We also have a task force in charge of after-sales for Asia (located in Bangkok).

After-sales department

01. Opening of a converter 02. Battery control 03. Flow meter calibration test 04. Electronic board fixing 05. Assembly of the converter after reparation 06. Software implementation

Our products

Flow meters for various application

Clamp-on, insertion & wetted probes

01 02

03

04

05

06

Page 8: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

Portable flow meters for full pipe applications

01. Uf 801 P converter linked to a computer 02. Minisonic P converter with 1586 probes03. Flow measurement in liquids with solids 04. Flow measurement on small diameter pipe 05. Flow measurement in difficult conditions

Product name minisonic P uf 801 P

nature of equiPment pORTABLE FLOW METER pORTABLE FLOW METER

media measured LIqUIDS LIqUIDS AnD gASES

conditions of use pIpE UnDER LOAD pIpE UnDER LOAD

PiPe diameter Up TO 3300mm Up TO 10000mm**

standard mountedinPuts/outPuts

› 2 cURREnT OUTpUTS, 4-20mA (gALvAnIcALLy ISOLATED - IMpEDAncE OF 1000Ω AS A pASSIvE OUTpUT AnD 150Ω AS An AcTIvE OUTpUT)

› 2 STATIc RELAy OUTpUTS (100v - 100mA - 10vA MAx)

oPtional inPuts/outPuts

— in oPtion, uP to 4 modules to choose from:

› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1

› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2

› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3

› 2 0-10v vOLTAgE InpUTS • module 4

› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)

› 2 cOnTAcT InpUTS (pULSE OR STATE) • module 6

ingress Protection Ip 67 Ip 68

accuracy* Up TO 0.5% Up TO 0.5%

troubleshooting helP — › OScILLOScOpE FUncTIOn (EchO DISpLAyED)

› gAIn

› qUALITy InDEx

maximum number of sPeed chords

2 chORDS 2 chORDS

models available STAnDARD / DUAL pIpE / DUAL chORD STAnDARD / DUAL pIpE / DUAL chORDcALORIMETER / DUAL cALORIMETER

0201

03

04

05

* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.

** AppLIcATIOn cOnDITIOnS FOR gAS MEASUREMEnT: pLEASE cOnTAcT US.

Page 9: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

01. Flow measurement on small diameter pipe02. Flow measurement of oil product03. Flow measurement with clamp-on probes04. Flow measurement with insertion probes

01

02 03

04

Fixed flow meters for full pipe applications

Product name minisonic 600 minisonic 2000

nature of equiPment FIxED FLOW METER FIxED FLOW METER

media measured LIqUIDS LIqUIDS

conditions of use pIpE UnDER LOAD pIpE UnDER LOAD

PiPe diameter Up TO 630mm Up TO 3300mm

standard mountedinPuts/outPuts

› 2 cURREnT OUTpUTS, 4-20mA (gALvAnIcALLy ISOLATED - IMpEDAncE OF 1000Ω AS A pASSIvE OUTpUT AnD 150Ω AS An AcTIvE OUTpUT)

› 2 STATIc RELAy OUTpUTS (100v - 100mA - 10vA MAx)

› 2 cURREnT OUTpUTS, 4-20mA (gALvAnIcALLy ISOLATED - IMpEDAncE OF 1000Ω AS A pASSIvE OUTpUT AnD 150Ω AS An AcTIvE OUTpUT)

› 2 STATIc RELAy OUTpUTS (100v - 100mA - 10vA MAx)

oPtional inPuts/outPuts

— —

ingress Protection Ip 67 Ip 67

accuracy* Up TO 0.5% Up TO 0.5%

troubleshooting helP — —

maximum number of sPeed chords

2 chORDS 2 chORDS

models available STAnDARD / DUAL pIpE (IDEnTIcAL pROBES) / DUAL chORD STAnDARD / DUAL pIpE (IDEnTIcAL pROBES) / DUAL chORD

exPlosion-Proof(atex) enclosure

— AvAILABLE

1/2

* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.

Page 10: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

Fixed flow meters for full pipe applications

Product name uf 811 uf 821 uf 831

nature of equiPment FIxED FLOW METER FIxED FLOW METER FIxED FLOW METER

media measured LIqUIDS LIqUIDS LIqUIDS

conditions of use pIpE UnDER LOAD pIpE UnDER LOAD pIpE UnDER LOAD

PiPe diameter Up TO 10000mm Up TO 10000mm Up TO 10000mm

standard mountedinPuts/outPuts

— — › 1 ISOLATED AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA

› 2 STATIc RELAy DIgITAL OUTpUTS (50v - 10mA) USABLE On FREqUEncy OUTpUTS

oPtional inPuts/outPuts

in oPtion, uP to 4 modules to choose from:

› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1

› 2 STATIc RELAy OUTpUTS (50v - 10mA) USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2

› 2 ISOLATED, pASSIvE cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3

› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4

› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)

› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6

in oPtion, uP to 4 modules to choose from:

› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1

› 2 STATIc RELAy OUTpUTS (50v - 10mA) USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2

› 2 ISOLATED, pASSIvE cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3

› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4

› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)

› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6

uP to 8 additional modules to choose from:

› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1

› 2 STATIc RELAy OUTpUTS (50v - 10mA) USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2

› 2 ISOLATED, pASSIvE cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3

› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4

› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)

› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6

ingress Protection Ip 67 Ip 67 Ip 67

accuracy* Up TO 0.5% Up TO 0.5% Up TO 0.5%

troubleshooting helP › OScILLOScOpE FUncTIOn (EchO DISpLAyED) › gAIn › qUALITy InDEx

› OScILLOScOpE FUncTIOn (EchO DISpLAyED) › gAIn › qUALITy InDEx

› OScILLOScOpE FUncTIOn (EchO DISpLAyED) › gAIn › qUALITy InDEx

maximum number of sPeed chords

2 chORDS 4 chORDS 8 chORDS

models available STAnDARD / DUAL pIpE / DUAL chORDcALORIMETER / DUAL cALORIMETER

SIngLE pIpE / MULTI-pIpE SIngLE pIpE / MULTI-pIpE

exPlosion-Proof(atex) enclosure

— AvAILABLE —

2/2

01. Flow measurement on big diameter GRP pipe02 & 03. Overspeed detection and flow measurement04 & 05. Multichords flow measurement for high precision

0201

03

04

05

* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.

Page 11: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

Product name uf 811 co uf 821 co uf 831 co / uf 831 rv

nature of equiPment FIxED FLOW METER FIxED FLOW METER FIxED FLOW METER

media measured LIqUIDS LIqUIDS LIqUIDS

conditions of use FREE SURFAcE FLOW FREE SURFAcE FLOW FREE SURFAcE FLOW

channel / river width Up TO 30m (In cLEAn WATER) Up TO 30m (In cLEAn WATER) › chAnnELS Up TO 30m (WIDTh)

› RIvERS Up TO 500m (DISTAncE BETWEEn BAnkS)

standard mountedinPuts/outPuts

› 2 ISOLATED, pASSIvE cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA

› 2 ISOLATED, pASSIvE cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA**

› 1 ISOLATED AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA

› 2 STATIc RELAy DIgITAL OUTpUTS (50v - 10mA) USABLE On FREqUEncy OUTpUTS

› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA**

oPtional inPuts/outPuts

uP to 3 additional modules to choose from:

› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1

› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2

› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3

› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4

› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)

› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6

uP to 3 additional modules to choose from:

› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1

› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2

› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3

› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4

› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)

› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6

uP to 7 additional modules to choose from:

› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1

› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2

› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3

› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4

› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)

› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6

ingress Protection Ip 67 Ip 67 Ip 67

accuracy* Up TO 0.5% Up TO 0.5% Up TO 0.5%

troubleshooting helP › OScILLOScOpE FUncTIOn (EchO DISpLAyED)

› gAIn

› qUALITy InDEx

› OScILLOScOpE FUncTIOn (EchO DISpLAyED)

› gAIn

› qUALITy InDEx

› OScILLOScOpE FUncTIOn (EchO DISpLAyED)

› gAIn

› qUALITy InDEx

maximum number of sPeed chords

2 chORDS 4 chORDS 8 chORDS

models available STAnDARD / DUAL chAnnELDUAL chORD

SIngLE chAnnELMULTI-chAnnEL / RIvER

SIngLE chAnnELMULTI-chAnnEL / RIvER

exPlosion-Proof(atex) enclosure

AvAILABLE

01. Flow measurement in partially filled pipes 02. Speed measurement on open channel 03 & 04. Flow measurement in natural rivers 05. Uf 831 CO in an electrical cabinet 06. Flow measurement in sewers 07. Flow measurement in river with 3 chords

02

03

06

01

04

07

05

Fixed flow meters for free surface flow applications

* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.

** MULTI-chAnnEL MODELS: 4 channels: 2 ISOLATED cURREnT InpUT MODULES 4-20mA, 0-20mA, 0-24mA (4 InpUTS) / 6 channels: 3 ISOLATED cURREnT InpUT MODULES 4-20mA, 0-20mA, 0-24mA (6 InpUTS) / 8 channels: 4 ISOLATED cURREnT InpUT MODULES 4-20mA, 0-20mA, 0-24mA (8 InpUTS).

Page 12: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

Product name minisonic Psd minisonic isd

nature of equiPment pIg AnD SphERE DETEcTOR InTERFAcE, SphERE AnD pIg DETEcTOR

media measured LIqUIDS AnD gASES LIqUIDS AnD gASES

conditions of use pIpE UnDER LOAD pIpE UnDER LOAD

PiPe diameter FROM 100 TO 1500mm / FROM 4’’ TO 60’’ FROM 100 TO 1500mm / FROM 4’’ TO 60’’

standard mountedinPuts/outPuts

› 2 STATIc RELAy OUTpUTS › 2 AnALOgUE OUTpUTS › 2 STATIc RELAy OUTpUTS

oPtional inPuts/outPuts

— —

ingress Protection Ip 67 Ip 67

accuracy* Up TO 0.5% Up TO 0.5%

models available STAnDARD / pORTABLE STAnDARD / pORTABLE

exPlosion-Proof enclosure

AvAILABLE WITh STAnDARD MODEL AvAILABLE WITh STAnDARD MODEL

dedicated Probes(certification atex ex mb ii t6)

Sxn-M 1524 / Sxn-M 1698 / Sxn-ME 1691 / Sxn-ME 1679

Product name minisonic g uf 811 g uf 821 g

nature of equiPment FIxED FLOW METER FIxED FLOW METER FIxED FLOW METER

media measured gASES gASES gASES

conditions of use pIpE UnDER LOAD pIpE UnDER LOAD pIpE UnDER LOAD

PiPe diameter Up TO 1500mm Up TO 1500mm Up TO 1500mm

standard mountedinPuts/outPuts

› 2 cURREnT OUTpUTS, 4-20mA: gALvAnIcALLy ISOLATED, IMpEDAncE OF 1000Ω AS A pASSIvE OUTpUT AnD 150Ω AS An AcTIvE OUTpUT

› 2 STATIc RELAy OUTpUTS (100v - 100mA - 10vA MAx)

— —

oPtional inPuts/outPuts

— uP to 4 modules to choose from:

› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1

› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2

› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3

› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4

› 2 pT100/pT1000 TEMpERATURE InpUTS • module 5 (dual)

› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6

uP to 4 modules to choose from:

› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1

› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2

› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3

› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4

› 2 pT100/pT1000 TEMpERATURE InpUTS • module 5 (dual)

› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6

ingress Protection Ip 67 Ip 67 Ip 67

accuracy* Up TO 0.5% Up TO 0.5% Up TO 0.5%

troubleshooting helP — › OScILLOScOpE FUncTIOn (EchO DISpLAyED) › gAIn› qUALITy InDEx

› OScILLOScOpE FUncTIOn (EchO DISpLAyED) › gAIn› qUALITy InDEx

maximum number of sPeed chords

2 chORDS 2 chORDS 4 chORDS

models available STAnDARD / DUAL pIpE / (IDEnTIcAL pROBES) / DUAL chORD

STAnDARD / DUAL pIpE / DUAL chORD SIngLE pIpE / MULTI-pIpE

exPlosion-Proof (atex) enclosure

AvAILABLE — AvAILABLE

01. Interface detection for oil products with clamp-on probes 02. Pig detection in gas pipeline with insertion probes 03. Sphere detection in liquid pipeline with insertion probes

* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.

* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.

Fixed flow meter for gas application

Interface and scrapper detectors for full pipe applications

0201

030201

01. Uf 841 G gas flow meter with its stainless steel explosion-proof enclosure02. Spool piece 2 chords for gas flow measurement

Page 13: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

Product name se 1714 se 1586 se 1662

PiPe diameter FROM 6 Up TO 20mm FROM 12 Up TO 115mm FROM 40 Up TO 1000mm

temPerature range -10°c TO +120°c -10°c TO +120°c -20°c TO +80°c

connectic pUSh-pULL pUSh-pULL pUSh-pULL / gLAnD cOnnEcTOR

frequency 4Mhz 2Mhz 500khz / 1Mhz

ingress Protection TypE Ip 67 TypE Ip 67 TypE Ip 67 / TypE Ip 68

dedicated suPPort IncLUDED IncLUDED SU-1707, SU-1517

atex version — — —

Product name se 1515 se 1595 se 1599

PiPe diameter FROM 40 Up TO 1000mm FROM 100 Up TO 2500mm FROM 100 Up TO 10000mm

temPerature range -20°c TO +180°c -20°c TO +80°c -20°c TO +120°c

connectic pUSh-pULL / gLAnD cOnnEcTOR pUSh-pULL / gLAnD cOnnEcTOR pUSh-pULL / gLAnD cOnnEcTOR

frequency 1Mhz 500khz 500khz

ingress Protection TypE Ip 67 / TypE Ip 68 TypE Ip 67 / TypE Ip 68 TypE Ip 67 / TypE Ip 68

dedicated suPPort SU-1707, SU-1517 SU-1735, SU-1629 SU-1735, SU-1629

atex version AvAILABLE (WITh gLAnD cOnnEcTOR OnLy) AvAILABLE (WITh gLAnD cOnnEcTOR OnLy) AvAILABLE (WITh gLAnD cOnnEcTOR OnLy)

Product name si 1614 si 1612 sxg 1708

aPPlication LIqUIDS LIqUIDS gAS

PiPe diameter FROM 80 Up TO 2000mm FROM 120 Up TO 4000mm FROM 80 Up TO 4000mm

temPerature range -10°c TO +60°c -10°c TO +60°c -10°c TO +60°c

connectic hEAD cOnnEcTOR hEAD cOnnEcTOR hEAD cOnnEcTOR

frequency 2Mhz / 3Mhz 1Mhz 250khz

ingress Protection TypE Ip 67 TypE Ip 67 TypE Ip 67

atex version — — yES (UnAvAILABLE In nOn-ATEx vERSIOn)

Product name sm 1690 sm 1689 sm 1684 sm 1681 sm 1666

aPPlication chAnnEL chAnnEL chAnnEL chAnnEL chAnnEL

distance between Probes FROM 3 Up TO 15m FROM 10 Up TO 30m FROM 30 Up TO 45m FROM 40 Up TO 80m FROM 70 Up TO 250m

temPerature range Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM

connectic gLAnD cOnnEcTOR gLAnD cOnnEcTOR gLAnD cOnnEcTOR gLAnD cOnnEcTOR gLAnD cOnnEcTOR

frequency 500khz 200khz 200 / 250khz 200khz 200khz

ingress Protection TypE Ip 68 TypE Ip 68 TypE Ip 68 TypE Ip 68 TypE Ip 68

atex version — — — — —

Product name sm 1654 sm 1686 sm 1527 sm 1613

aPPlication chAnnEL chAnnEL chAnnEL chAnnEL

distance between Probes FROM 1 Up TO 4m FROM 2 Up TO 15m FROM 3 Up TO 15m FROM 3 Up TO 15m

temPerature range Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM

connectic gLAnD cOnnEcTOR gLAnD cOnnEcTOR gLAnD cOnnEcTOR gLAnD cOnnEcTOR

frequency 1Mhz 500khz 500khz 500khz

ingress Protection TypE Ip 68 TypE Ip 68 TypE Ip 68 TypE Ip 68

atex version — — AvAILABLE —

Ultraflux develops its own range of probes in order to perfectly suit with its converters. Our engineers create clamp-on, insertion and wetted probes. You will find below a few examples of them. This list is not exhaustive. For more information about all our available probes, please contact us.

Ultraflux probes

Clamp-on probes

Insertion probes

Wetted probes

Page 14: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

Ultraflux transit-time flow measurement guidelines

Direct mode for intrusive probes

For a measurement with insertion probes, direct mode is used in most cases. However, reflex mode (V) may sometimes be used in specific conditions. Ultraflux determines the best solution depending on your application.

A settings window on Ultraflux PC software

A measurement window on Ultraflux PC software

Probes set-upsVarious possibilities for clamp-on probes

with clamp-on probes with insertion probes

c : sPeed of sound / vus

: velocity on the ultrasonic Path / Kh : hydraulic correction factor / q : flow / v : velocity / s : section

Measuring principle of ultrasonic transit time flow meters

mode reflex (or v) direct (or /) n w

Probes installation pROBES pLAcED On ThE SAME SIDE OF ThE pIpE, On A SAME gEnERATRIx - ThE ULTRASOnIc WAvE BEIng REFLEcTED OncE

pROBES pLAcED On BOTh SIDES OF ThE pIpE AnD ORIEnTED TOWARDS EAch OThER

pROBES pLAcED On BOTh SIDES OF ThE pIpE - ThE ULTRASOnIc WAvE BEIng REFLEcTED TWIcE

pROBES pLAcED On ThE SAME SIDE OF ThE pIpE, On A SAME gEnERATRIx - ThE ULTRASOnIc WAvE BEIng REFLEcTED ThRIcE

condition of use REcOMMAnDED In MOST cASES. AccURATE AnD EASy TO InSTALL

WhEn ThE pIpE cOnDITIOn DOES nOT ALLOW ThE USE OF REFLEx MODE. In cASE OF cORRODED pIpE, ABSORBEnT OR LOADED FLUID, MULTI-pRODUcT AppLIcATIOnS

pIpE DIAMETERS LESS ThAn 50 mm, LOW FLOW, gOOD InTERnAL pIpE cOnDITIOnS

pIpE DIAMETERS LESS ThAn 50 mm, LOW FLOW, gOOD InTERnAL pIpE cOnDITIOnS

Reflex (or V) mode Direct (or /) mode N and W mode

tab

= l / (c + vus

cos θ)

tba

= l / (c - vus

cos θ)

∆t = tba

– tab

v = Kh.vus

q = v.s

vus

=l2

tab

2d

∆t

tba

.

Our products can be configured from your PC or directly via the converter

Ultraflux PC software

Choice of operating mode

Page 15: Ultrasonic Flow Meters Expertise Innovation Service · 2015-09-19 · Expertise Innovation Service. Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing

ultrafluxBâtiment Texas – Éragny Parc9 allée Rosa Luxemburg95610 Éragny sur Oise, FranceP. +33 (0)1 30 27 27 30F. +33 (0)1 30 39 84 34www.ultraflux.fr

ultraflux asia co ltd. 262-268 Worachak Road,Baanbart, Pomprab-sattrupai10100 Bangkok, ThailandP. +66 (0) 2621 1848F. +66 (0) 2621 1849www.ultraflux.com

ultraflux serviços e equipamentosRua do Livramento 125-1° AndarSaúde20221-192 Rio de Janeiro-RJ, BrazilP / F. +55 21 3575 [email protected]