ul test report and procedure - .net framework

73
Issue Date: 2016-08-12 Page 1 of 9 Report Reference # E476677-A3-UL 2017-11-09 Copyright © 2017 UL TEST REPORT AND PROCEDURE Standard: UL 60950-1, 2nd Edition, 2014-10-14 (Information Technology Equipment - Safety - Part 1: General Requirements) CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment - Safety - Part 1: General Requirements) Certification Type: Listing CCN: QQGQ, QQGQ7 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment) Product: AC ADAPTER Model: XRN-069, XRN-068, XRN-067, XRN-066, XRN-065, AHR-067, AHR- 065, AHR-068, AHR-069, MIC-WCN01, MIC-WCN02 Rating: Input: 100-240 Vac, 50/60 Hz, 0.3A; Output: 5.0Vdc, 2.1A. Applicant Name and Address: SHENZHEN ANHAORUIHE ELECTRONICS CO LTD #2 BUILDING ANHAORUI INDUSTRIAL PARK JIANAN ROAD TANGWEI FUYONG TOWN BAOAN DISTRICT SHENZHEN GUANGDONG 518103 CHINA This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow- Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Cynthia Xiao(T) / Ken Zhang Reviewed by: Alex Luo Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Upload: others

Post on 30-Oct-2021

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 1 of 9 Report Reference # E476677-A3-UL2017-11-09

Copyright © 2017

UL TEST REPORT AND PROCEDURE

Standard: UL 60950-1, 2nd Edition, 2014-10-14 (Information Technology Equipment - Safety - Part 1: General Requirements)CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment - Safety - Part 1: General Requirements)

Certification Type: ListingCCN: QQGQ, QQGQ7 (Power Supplies for Information Technology

Equipment Including Electrical Business Equipment)

Product: AC ADAPTERModel: XRN-069, XRN-068, XRN-067, XRN-066, XRN-065, AHR-067, AHR-

065, AHR-068, AHR-069, MIC-WCN01, MIC-WCN02Rating: Input: 100-240 Vac, 50/60 Hz, 0.3A;

Output: 5.0Vdc, 2.1A.

Applicant Name and Address: SHENZHEN ANHAORUIHE ELECTRONICS CO LTD#2 BUILDING ANHAORUI INDUSTRIAL PARKJIANAN ROAD TANGWEIFUYONG TOWN BAOAN DISTRICTSHENZHENGUANGDONG 518103 CHINA

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure.

The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.

Prepared by: Cynthia Xiao(T) / Ken Zhang Reviewed by: Alex Luo

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

ACampbell
Typewritten Text
ACampbell
Typewritten Text
ACampbell
Typewritten Text
ACampbell
Typewritten Text
32196 - Night Light USB Wall Adapter
ACampbell
Highlight
Page 2: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 2 of 9 Report Reference # E476677-A3-UL2017-11-09

Supporting DocumentationThe following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions -

i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report.

ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report.

iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Product DescriptionDirect-plug-in Adapter for ITE. All electrical components are mounted on a PWB and housed in a plastic enclosure. The enclosure is secured by ultrasonic weld.

Model Differences- Models XRN-069, XRN-068, XRN-067, XRN-066, XRN-065, AHR-067, AHR-065 have same circuit diagram, input and output specifications and the same enclosure materials, only difference for the PWB layout and enclosure shape.- Models AHR-068 and MIC-WCN01 are identical to model AHR-065 except for model designation, models AHR-069 and MIC-WCN02 are identical to model AHR-067 except for model designation.

Technical Considerations Equipment mobility : direct plug-in Connection to the mains : pluggable A Operating condition : continuous Access location : operator accessible Over voltage category (OVC) : OVC II Mains supply tolerance (%) or absolute mains supply values : +10%, -10% (Declared by

manufacturer) Tested for IT power systems : No IT testing, phase-phase voltage (V) : N/A Class of equipment : Class II (double insulated) Considered current rating of protective device as part of the building installation (A) : 20 Pollution degree (PD) : PD 2 IP protection class : IP X0 Altitude of operation (m) : 2000 Altitude of test laboratory (m) : less than 2000 meters Mass of equipment (kg) : Aprox. 0.067 The product was submitted and evaluated for use at the maximum ambient temperature (Tma)

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 3: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 3 of 9 Report Reference # E476677-A3-UL2017-11-09

permitted by the manufacturer’s specification of: 40 degree C The means of connection to the mains supply is: Pluggable A (DPIU) The product is intended for use on the following power systems: TN The equipment disconnect device is considered to be: Plug The product was investigated to the following additional standards: The blade dimension was

evaluated to be complied with NEMA configurations in accordance with Wiring Devices -Dimensional Specifications, ANSI/NEMA WD6., Direct Plug-in Equipment complies with UL1310 mechanical assembly requirements.

The following accessible locations (with circuit/schematic designation) are within a limited current circuit: CY1 Secondary Pin

The following circuit locations (with circuit/schematic designation) were investigated as a limited power source (LPS): USB Output Terminal

Additional InformationN/AAdditional StandardsThe product fulfills the requirements of: N/AMarkings and instructionsClause Title Marking or Instruction Details Power rating - Ratings

Ratings (voltage, frequency/dc, current)

Power rating -Company identification

Listee's or Recognized company's name, Trade Name, Trademark or File Number

Power rating -Model

Model Number

Power rating -Class II symbol

Symbol for Class II construction

(60417-2-IEC-5172)

LPS marking (Optional) "L.P.S", "LPS" or "Limited Power Source"

Marking for Fusing Resistor

Rated 2R/0.5W and located on or adjacent to Fusing Resistor (FR1).

Special Instructions to UL RepresentativeInspect the transformer(s) listed in Production-Line Testing Requirements (Electric Strength Test Special

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 4: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 4 of 9 Report Reference # E476677-A3-UL2017-11-09

Constructions) per AA1.1- (C). When the tests are conducted at other location, Inspect test record and specification sheet provided by the component manufacturer. Verify the specification sheet indicates 100% routine test specified in Production-Line Testing Requirements (Electric Strength Test Special Constructions) be conducted at the component manufacturer.

Production-Line Testing RequirementsElectric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for further information.

Model ComponentRemovable

Parts Test probe locationV

rms V dcTest Time,

sAll models Transformer -- Primary pins to

secondary pins3000

4242 Minimum 1

Earthing Continuity Test Exemptions - This test is not required for the following models:All models in this report.

Electric Strength Test Exemptions - This test is not required for the following models:--

Electric Strength Test Component Exemptions - The following solid-state components may be disconnected from the remainder of the circuitry during the performance of this test:--

Sample and Test Specifics for Follow-Up Tests at UL

Model Component Material Test Sample(s) Test

Specifics -- -- -- -- -- --

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 5: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 5 of 9 Report Reference # E476677-A3-UL2017-11-09

1.5.1 TABLE: list of critical components PassObject/part or Description

Manufacturer/ trademark

type/model technical data Product Category CCN(s)

Required Marks of Conformity

Supplement ID

01. Label Interchangeable Interchangeable Minimum 80 degree C, suitable for enclosure

PGDQ2 or PGJI2 UL

01a. Label (Alternate) -- -- Laser engraved -- --02. Plastic Enclosure and plug holder

SABIC JAPAN L L C 945 (GG) Rated V-0, HWI=3, Minimum 1.5mm thickness, 120 degree C. Plastic enclosure secured together by ultra-sonic welding.

QMFZ2 UL (E161759)

03. Input blade -- -- Copper or Copper alloy, non-polarized (NEMA 1-15P configuration). Integrally melded onto plug holder, the perimeter of the face section from which the blade projection is minimum 5.1 mm from any point on either blade.

-- --

04. PWB Interchangeable Interchangeable V-1 or better, Minimum 130 degree C.

ZPMV2 UL

05. Fusible resistor (FR1)

KAIHUA INDUSTRIAL HONG KONG LTD

FKN-1/2W 2ohm, Min 0.5W FPEW2 UL (E341249)

06. Bridge Diode (BD1) -- -- Minimum 600 V, minimum 0.5A -- --07. Electrolytic Capacitor (C1, C2)

-- -- Rated C1:10uF, C2: 15uF. 400 V, minimum 105 degree C

-- --

08. Current Sensor Resistors (R5, R6)

-- -- Each Minimum 1.3 Ohm, minimum 1W.

-- --

09. Choke (L1) -- -- Color-ring type. Rated 330uH, tolerance 10%.

-- --

10. Choke (L2) -- -- Color-ring type. Rated 4.7uH, tolerance 10%.

-- --

11. Transformer (T1) SHENZHEN CITY FLAME ELECTRONICS TECH CO LTD

EE13-052101 Class B, see enclosure ID 4-01 for details.

-- -- 4-01

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 6: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 6 of 9 Report Reference # E476677-A3-UL2017-11-09

11-1. Transformer (T1)-insulation system

SHENZHEN CITY FLAME ELECTRONICS TECH CO LTD

TaYa 130-1 Class 130(B). OBJY2 UL (E477536)

11-2. Transformer (T1) -coil (primary)

Interchangeable Interchangeable Copper magnet wire wound concentrically on bobbin. Minimum 130 degree C.

OBMW2 UL

11-3. Transformer (T1) -Bobbin

CHANG CHUN PLASTICS CO LTD

T375J Phenolic, rated V-0, minimum. 150 degree C, minimum 0.75mm thickness.

QMFZ2 UL (E59481)

11-4. Transformer (T1) -Insulation Tape

JINGJIANG YAHUA PRESSURE SENSITIVE GLUE CO LTD

CT (b)(g), CT* (c)(g)

Minimum 130 degree C OANZ2 UL (E165111)

11-5. Transformer (T1) -Triple Insulation wire

TA YA ELECTRIC WIRE & CABLE CO LTD

TILW-B Minimum 130 degree C OBJT2 UL (E225803)

11-6. Transformer (T1) -Varnish

ELANTAS ELECTRICAL INSULATION ELANTAS PDG INC

468-2 (d) Minimum 130 degree C OBOR2 UL (E75225)

11-7. Transformer (T1) -Tubing

GREAT HOLDING INDUSTRIAL CO LTD

TFL Minimum 200 degree C. VW-1. YDPU2 UL

11-8. Transformer (T1) -Core

-- -- Ferrite. EE13.. -- --

12. PWM Control IC (U1) WUXI CHIP HOPE MICRO-ELECTRONICS LTD

LP3783 -- -- --

13. Secondary IC (U2) WUXI CHIP HOPE MICRO-ELECTRONICS LTD

LP3515 -- -- --

14. Y Cap (CY1) (Optional)

SHANTOU HIGH-NEW TECHNOLOGY DEVELOPMNT ZONE SONGTIAN ENTERPRISE CO

CD, CE Each Max.1000pF, Min.250 Vac, Min.125 degree C, Y1 type.

FOWX2 UL (E208107)

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 7: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 7 of 9 Report Reference # E476677-A3-UL2017-11-09

LTD15. Primary lead wire Interchangeable Interchangeable Minimum 24 AWG, minimum

300 V, minimum 105 degree C.AVLV2 UL

16. USB port Interchangeable Interchangeable Copper alloys housed by metal case and additionally supported by plastic rated minimum V-2.

QMFZ2 UL

17. Plastic insulation sheet (Between Pri. and Sec.) (For Models XRN-068, XRN-066, AHR-065, AHR-068, MIC-WCN01)

KUNSHAN DOBESTY OPTOELECTRONIC MATERIALS CO LTD (E339070)

PC9842B Rated V-2 min, 80 degree C. Minimum 0.45 mm thickness. See enclosure ID 7-07, 7-08, 7-11.

QMFZ2 UL

18. Heat-shrinkable tube (on FR1 and internal wire)

Interchangeable Interchangeable Rated VW-1, minimum 300V, minimum 125 degree C.

YDPU2 UL

19. Heat-shrinkable tube (on Pri. Cap EC2) (Only for Model XRN-067)

Interchangeable Interchangeable Rated VW-1, minimum 300V, minimum 125 degree C.

YDPU2 UL

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 8: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 8 of 9 Report Reference # E476677-A3-UL2017-11-09

Enclosures

Type Supplement Id DescriptionPhotographs 3-01 Top Overview for XRN-069Photographs 3-02 Blade Overview for XRN-069Photographs 3-03 Output Overview for XRN-069Photographs 3-04 Internal Overview for XRN-069Photographs 3-05 PWB Bottom Side view for XRN-069Photographs 3-06 Blade Overview for XRN-068Photographs 3-07 Output Overview for XRN-068Photographs 3-08 Internal Overview for XRN-068Photographs 3-09 Component Side View for XRN-068Photographs 3-10 PWB Bottom Side View for XRN-068Photographs 3-11 Blade Overview for XRN-067Photographs 3-12 Output Overview for XRN-067Photographs 3-13 Internal Overview for XRN-067Photographs 3-14 Component Side View for XRN-067Photographs 3-15 PWB Bottom Side View for XRN-067Photographs 3-16 Blade Overview for XRN-066Photographs 3-17 Output Overview for XRN-066Photographs 3-18 Internal Overview for XRN-066Photographs 3-19 Component Side View for XRN-066Photographs 3-20 PWB Bottom Side View for XRN-066Photographs 3-21 Blade Overview for XRN-065Photographs 3-22 Output Overview for XRN-065Photographs 3-23 Component Side View for XRN-065Photographs 3-24 PWB Bottom Side View for XRN-065Photographs 3-25 Transformer Internal ViewPhotographs 3-26 Top Overview for AHR-067Photographs 3-27 Blade Overview for AHR-067Photographs 3-28 Output Overview for AHR-067Photographs 3-29 Internal Overview for AHR-067Photographs 3-30 PWB Bottom Side view for AHR-067Photographs 3-31 Top Overview for AHR-065Photographs 3-32 Blade Overview for AHR-065Photographs 3-33 Output Overview for AHR-065Photographs 3-34 Internal Overview for AHR-065

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 9: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 9 of 9 Report Reference # E476677-A3-UL2017-11-09

Photographs 3-35 PWB Bottom Side view for AHR-065Diagrams 4-01 T1 Spec

Schematics + PWB 5-01 PWB Layout for XRN-069Schematics + PWB 5-02 PWB Layout for XRN-068Schematics + PWB 5-03 PWB Layout for XRN-067Schematics + PWB 5-04 PWB Layout for XRN-066Schematics + PWB 5-05 PWB Layout for XRN-065Schematics + PWB 5-06 PWB Layout for AHR-067, AHR-069, MIC-WCN02Schematics + PWB 5-07 PWB Layout for AHR-065, AHR-068, MIC-WCN01

Miscellaneous 7-01 Blade DimensionMiscellaneous 7-02 Enclosure Drawing (XRN-069)Miscellaneous 7-03 Enclosure Drawing (XRN-068)Miscellaneous 7-04 Enclosure Drawing (XRN-067)Miscellaneous 7-05 Enclosure Drawing (XRN-066)Miscellaneous 7-06 Enclosure Drawing (XRN-065)Miscellaneous 7-07 Insulation Sheet Drawing Between Pri. and Sec.(XRN-066)Miscellaneous 7-08 Insulation Sheet Drawing Between Pri. and Sec.(XRN-068)Miscellaneous 7-09 Enclosure Drawing(AHR-067, AHR-069, MIC-WCN02)Miscellaneous 7-10 Enclosure Drawing(AHR-065, AHR-068, MIC-WCN01)Miscellaneous 7-11 Insulation Sheet Drawing between Pri. and Enclosure(AHR-065,

AHR-068, MIC-WCN01)

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 10: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-01

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 11: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-02

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 12: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-03

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 13: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-04

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 14: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-05

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 15: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-06

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 16: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-07

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 17: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-08

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 18: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-09

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 19: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-10

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 20: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-11

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 21: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-12

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 22: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-13

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 23: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-14

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 24: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-15

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 25: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-16

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 26: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-17

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 27: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-18

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 28: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-19

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 29: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-20

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 30: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-21

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 31: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-22

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 32: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-23

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 33: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-24

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 34: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-25

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 35: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-26

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 36: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-27

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 37: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-28

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 38: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-29

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 39: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-30

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 40: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-31

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 41: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-32

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 42: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-33

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 43: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-34

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 44: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 PHO-35

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 45: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 DIA-01

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 46: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 DIA-01

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 47: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 SCH-01

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 48: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 SCH-02

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 49: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 SCH-03

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 50: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 SCH-04

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 51: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 SCH-05

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 52: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 SCH-06

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 53: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 SCH-07

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 54: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 MIS-01

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 55: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 MIS-02

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 56: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 MIS-03

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 57: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 MIS-04

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 58: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 MIS-05

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 59: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 MIS-06

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 60: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 MIS-07

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 61: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 MIS-08

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 62: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 MIS-09

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 63: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 MIS-10

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 64: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 MIS-11

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 65: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 1 of 6 Report Reference # E476677-A3-ULRevision Date: 2017-11-09 Test Record

Test Record No. 1-- The manufacturer submitted representative production samples of AC ADAPTER, Models XRN-069, XRN-068, XRN-067, XRN-066 and XRN-065 for investigation.

-- Unless otherwise indicated in each test item of the datasheet, all tests were conducted on Models XRN-069, XRN-068, XRN-067, XRN-066 and XRN-065.

-- For the test WEIGHT AND MOMENT DETERMINATION: (DIRECT PLUG-IN UNIT) in the datasheet, conducted in accordance with UL1310 according UL 60950 PAG and indicated that the tests and evaluation are acceptable by UL1310 according UL 60950 PAG.

-- Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL.

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 66: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 2 of 6 Report Reference # E476677-A3-ULRevision Date: 2017-11-09 Test Record

The following tests were conducted:Test Testing Location/CommentsEnd Product Reference PageGeneral GuidelinesPower Supply Reference PageInput: Single-Phase (1.6.2)Energy Hazard Measurements (2.1.1.5, 2.1.2, 1.2.8.10)SELV Reliability Test Including Hazardous Voltage Measurements (2.2.2, 2.2.3, 2.2.4, Part 22 6.1)Limited Current Circuit Measurement (2.4.1, 2.4.2)Limited Power Source Measurements (2.5)Humidity (2.9.1, 2.9.2, 5.2.2)Determination of Working Voltage; Working Voltage Measurement (2.10.2)Thin Sheet Material (2.10.5.9, 2.10.5.10, 2.10.5.6)Transformer and Wire /Insulation Electric Strength (2.10.5.13)Steady Force (4.2.1 - 4.2.4)Drop (4.2.6, 4.2.1)Stress Relief (4.2.7, 4.2.1)Direct Plug-In Equipment-Moment (4.3.6)Direct Plug-In Blade Securement (4.3.6)Direct Plug-In Security of Input Contacts (4.3.6)Direct Plug-In Resistance to Crushing (4.3.6)Direct Plug-In Rod Pressure (4.3.6)Direct Plug-In Input Blade Endurance (4.3.6)Heating (4.5.1, 1.4.12, 1.4.13)Ball Pressure (4.5.5, 4.5)Touch Current (Single-Phase; TN/TT System) (5.1, Annex D)Electric Strength (5.2.2)Component Failure (5.3.1, 5.3.4, 5.3.7)Power Supply Output Short-Circuit/Overload (5.3.7)

Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report.

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 67: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 3 of 6 Report Reference # E476677-A3-ULRevision Date: 2017-11-09 Test Record

The following tests were waived:Test Rationale for WaivingTransformer Abnormal Operation (5.3.3, 5.3.7b, Annex C.1) Covered by 5.3.7 Power Supply

Output Overload

The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id DescriptionAttachment 2-01 CRDDatasheet 2-02 Test Datasheet

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 68: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 4 of 6 Report Reference # E476677-A3-ULRevision Date: 2017-11-09 Test Record

Test Record No. 2-- Revision of 4788142895: The manufacturer submitted representative production sample of AC Adapter models AHR-065, AHR-067, AHR-068, AHR-069, MIC-WCN01, MIC-WCN02 employing alternate enclosure shape and PWB layout with tests.-- Unless otherwise indicated, all tests were conducted in UL-CCIC Company Limited, Guangzhou Branch under In-House Program.-- Unless otherwise indicated, all tests were conducted on Model AHR-065 and AHR-067.-- Tests performed on Model AHR-065 and AHR-067 were considered to be representative of model AHR-068, AHR-069, MIC-WCN01, MIC-WCN02.-- For the tests DIRECT PLUG-IN EQUIPMENT-MOMENT TEST, DIRECT PLUG-IN BLADE SECUREMENT TEST, DIRECT PLUG-IN SECURITY OF INPUT CONTACTS, DIRECT PLUG-IN RESISTANCE TO CRUSHING, DIRECT PLUG-IN ROD PRESSURE TEST, DIRECT PLUG-IN - INPUT BLADE ENDURANCE in the datasheet, conducted per the standard for Class 2 Power Units, UL 1310, Sixth Edition, Last Revise date Aug. 26, 2011. -- For the test WEIGHT AND MOMENT DETERMINATION: (DIRECT PLUG-IN UNIT) in the datasheet, conducted in accordance with UL1310 according UL 60950 PAG and indicated that the tests and evaluation are acceptable by UL1310 according UL 60950 PAG. -- Test results relate only to the items tested.-- Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 69: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 5 of 6 Report Reference # E476677-A3-ULRevision Date: 2017-11-09 Test Record

The following tests were conducted:Test Testing Location/CommentsEnd Product Reference PagePower Supply Reference PageInput: Single-Phase (1.6.2)Energy Hazard Measurements (2.1.1.5, 2.1.2, 1.2.8.10)SELV Reliability Test Including Hazardous Voltage Measurements (2.2.2, 2.2.3, 2.2.4, Part 22 6.1)Limited Current Circuit Measurement (2.4.1, 2.4.2)Limited Power Source Measurements (2.5)Humidity (2.9.1, 2.9.2, 5.2.2)Determination of Working Voltage; Working Voltage Measurement (2.10.2)Transformer and Wire /Insulation Electric Strength (2.10.5.13)Steady Force (4.2.1 - 4.2.4)Drop (4.2.6, 4.2.1)Stress Relief (4.2.7, 4.2.1)Direct Plug-In Equipment-Moment (4.3.6)Direct Plug-In Blade Securement (4.3.6)Direct Plug-In Security of Input Contacts (4.3.6)Direct Plug-In Resistance to Crushing (4.3.6)Direct Plug-In Rod Pressure (4.3.6)Direct Plug-In Input Blade Endurance (4.3.6)Heating (4.5.1, 1.4.12, 1.4.13)Ball Pressure (4.5.5, 4.5)Touch Current (Single-Phase; TN/TT System) (5.1, Annex D)Electric Strength (5.2.2)Component Failure (5.3.1, 5.3.4, 5.3.7)Power Supply Output Short-Circuit/Overload (5.3.7)

Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report.

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 70: UL TEST REPORT AND PROCEDURE - .NET Framework

Issue Date: 2016-08-12 Page 6 of 6 Report Reference # E476677-A3-ULRevision Date: 2017-11-09 Test Record

The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id DescriptionAttachment 2-03 CRDDatasheet 2-04 Test Record

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 71: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 01-ATT-01

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 72: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 01-ATT-01

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00

Page 73: UL TEST REPORT AND PROCEDURE - .NET Framework

File E476677 03-ATT-03

Created by UL Document Assembler 2017-11-14 20:46:51 -06:00