uk acc catalog issue 2 - trylon accessory catalogue web 2016.pdf · anixter is a proud distributor...

66
ACCESSORY CATALOGUE UK and Ireland Issue 2 www.trylon.com

Upload: others

Post on 15-Sep-2019

6 views

Category:

Documents


1 download

TRANSCRIPT

ACCESSORY CATALOGUE UK and IrelandIssue 2

www.trylon.com

ABOUT US

Anixter is a leading global supplier of communications and security products and electrical and electronic wire and cable. We help our customers specify solutions and make informed purchasing decisions around technology, applications and relevant standards. Throughout the world, we provide innovative supply chain management solutions to reduce our customers’ total cost of production and implementation.

“ Anixter’s value to customers can be summed up in the depth and breadth of our inventory, application-specific technical and product knowledge, and a wide array of inventive Supply Chain Solutions mapped to our customers’ specific requirements.”

Bob Eck, President & CEO

ANIXTER IS A PROUD DISTRIBUTOR OF TRYLON PRODUCTS.

UNITED KINGDOM AND IRELAND

INDUSTRIALAberdeen Oil and Gas Tel: +44 (0)1224 275680

Birmingham Construction Tel: +44 (0)121 322 7140

Dublin Construction Tel: +353 1 257 2000

Glasgow Construction Tel: +44 (0)1698 503810

Uxbridge Construction Tel: +44 (0)845 604 1301

Warrington Construction Tel: +44 (0)1925 810121

Warrington Rail Tel: +44 (0)870 242 2822

anixter.co.uk

anixter.ie

OEMBarrow-in-Furness Tel: +44 (0)1229 825871

Chesterfield Tel: +44 (0)1246 451600

Coventry Tel: +44 (0)24 7646 5829

Diss Tel: +44 (0)1379 643506

Glasgow Tel: +44 (0)141 445 2193

Leeds Tel: +44 (0)113 244 0321

Liverpool Tel: +44 (0)151 355 2211

Luton Tel: +44 (0)1582 498900

Newcastle Tel: +44 (0)191 482 7660

Plymouth Tel: +44 (0)1752 341100

Portsmouth Tel: +44 (0)23 9286 5469

Sheffield Tel: +44 (0)1142 709300

Warrington Marine and Defence Tel: +44 (0)1925 816166

anixter.co.uk

FOR FURTHER INFORMATION CONTACT YOUR LOCAL ANIXTER REPRESENTATIVE.

PHONE, FAX, EMAIL WITH SALES REP

B2B INTEGRATION (E.G., EDI, JIT, ERP SYSTEMS)

EPROCUREMENTPUNCHOUT CATALOG(E.G., ARIBA, SCIQUEST)

CUSTOM CATALOG(E.G., INTELLIBID, ACCUBID)

ANIXTER.COM(RETAIL PRICING)

EANIXTER.COM(CONTRACT PRICING)

CUSTOMER BRANDED E-COMMERCE WEBSITE(CONTRACT PRICING)

PHYSICAL STORES ELECTRONIC INVOICES AND PAYMENTSCONSOLIDATED INVOICESTATEMENTS Major enhancements coming soon.

AUTOMATED ORDER CONFIRMATION AND SHIPMENT NOTIFICATION

eAnixter.com

DIFFERENT WAYS TO BUY FROM ANIXTER

GLOBAL REACH. LOCAL ADVANTAGE.With Anixter, you get a true local partner around the world. No other distributor of our kind can claim an in-country presence in more than 50 countries and 300 cities.

We do business in more than 35 currencies and 30 languages, which means we are uniquely positioned to help facilitate your project in the local environment, reduce risks and keep costs down.

CORPORATE SNAPSHOT

500,000PRODUCTS

OVER

50COUNTRIES

APPROXIMATELY

$$1.1 BILLIONINVENTORY

IN

300CITIES

STOCK SYMBOL

AXEFORTUNE

500 LIST

NUMBER OFEMPLOYEES

APPROXIMATELY 9,100

YEAR FOUNDED

1957APPROXIMATELY

100,000CUSTOMERS

270WAREHOUSES/

BRANCHES

Anixter Inc. World Headquarters2301 Patriot BoulevardGlenview, Illinois 60026224.521.8000

Wire & Cable EMEA HeadquartersUnit A, The BeaconsBirchwood ParkBirchwood, WarringtonCheshire, WA3 6GP+44 (0) 1925 838658

[email protected] www.trylon.com 4

CE Product Cer fi ca on Example ....................6

Mount Calcula on Example ............................7

Antenna/MW Standoff Mounts ......................8

Yoke Bracket Mount .......................................9

Light Duty Wall Mount Assembly ..................10

Wall Mount Assembly ..................................11

Corner Mount Assembly ...............................12

Pipe Extension Assembly ..............................13

3-Pipe 3-Sector Spine Mount ........................14

6-Pipe 3-Sector Spine Mount ........................15

Pole Ring Standoff ........................................16

2-Level Pole Ring Standoff ............................17

2L 6P Pole Ring Standoff ...............................18

Bulk Pipe ......................................................19

Light Duty Roo op Ballast Mount .................20

Single Pipe Roof Ballast Mount .....................21

Double Pipe Roof Ballast Mount ...................22

Step Bolt Assembly .......................................24

4-Hole Feeder Bracket ..................................25

6-Hole Feeder Bracket ..................................26

Gantry Poles .................................................27

Fixed Crossover Assembly .............................28

Universal Fixed Crossover Assembly .............29

2-Way RRU Mount ........................................30

3-Way RRU Mount ........................................31

4-Way RRU Mount ........................................32

Installa on Drawings ....................................33Antenna/MW Standoff Mount Installa on ..............................33Yoke Bracket Mount Installa on ...............................................36Yoke Bracket Mount Without Pipe Installa on .........................37Light Wall Mount Installa on ...................................................38Wall Mount Installa on ............................................................39Corner Mount Installa on ........................................................40Pipe Extension Assembly Installa on .......................................413-Pipe 3-Sector Spine Mount Installa on .................................423-Pipe 3-Sector Spine Mount Without Pipe Installa on ...........436-Pipe 3-Sector Spine Mount Installa on .................................446-Pipe 3-Sector Spine Mount Without Pipe Installa on ...........45Pole Ring Standoff Installa on ..................................................46Pole Ring Standoff Without Pipe Installa on ...........................472-Level Pole Ring Standoff Installa on .....................................482L 6P Pole Ring Standoff Installa on ........................................49Light Duty Roof Ballast Mount Installa on ...............................50Single Pipe Roof Ballast Mount Installa on ..............................51Double Pipe Roof Ballast Mount Installa on ............................524-Hole Feeder Bracket Installa on ...........................................546-Hole Feeder Bracket Installa on ...........................................55Gantry poles Installa on ..........................................................56Fixed Cross Over Assemblies Installa on..................................57Universal Fixed Cross Over Assemblies Installa on ..................592-Way RRU Mount Installa on .................................................603-Way RRU Mount Installa on .................................................614-Way RRU Mount Installa on .................................................62

Trylon Also Off ers .........................................64

TABLE OF CONTENTS

Table of Contents

[email protected] www.trylon.com 5

CE PRODUCT CERTIFICATION

EXAMPLE

Identification No. 1381 of Notified Body Trylon TSF

21 South Field Drive Elmira, Ontario

Canada N2B 0A6

14 Kit Part #4.927.0103.001

Essential Characteristics Declared Performance Harmonized Technical Specification

Tolerances on dimensions and shape

In accordance with EN 1090-2 EN 1090-1:2009

Weldability Based in S355JR Material, Max CEV % is 0.543

Fracture toughness / brittle strength

As per EN 10025:2004 requirements for S275JR & S355JR steel - 27 J at 20° C

Impact resistance See Above.

Load bearing capacity As per EN-1993-3-1 (2007), Minimum capacity is 4.2kN

Deformation at serviceability limit state

As per EN-1993-3-1 (2007), Maximum deflection is 0.6mm

Fatigue strength NPD

Resistance to fire As per EN-13501-1, REI 180

Reaction to fire As per EN-13501-2, A1

Release of Cadmium and its compounds

NPD

Emission of Radioactivity NPD

Durability All products Galvanized to European EN ISO 1461

[email protected] www.trylon.com 6

CE PRODUCT CERTIFICATION

EXAMPLE

Declaration of Performance (according to REGULATION (EU) No 305/2011)

Kit Description: MW Standoff Mount (1m Pipe) Kit Part Number: 4.927.0103.001 DoP Number: 4.927.0103.001 Applicable Harmonized Standard: EN 1090-1:2009 Intended Usage: Antenna Support Mount Manufacturer Information: Trylon TSF 21 South Field Drive Elmira, Ontario Canada N2B 0A6 Tel: (519) 669 – 5421 Website: www.Trylon.com CE Marking Notified Body: SGS Italia S.p.A. Via G. Gozzi 1/a Milan, 20129 Italy Tel: +39 02 73 931 Website: www.sgsgroup.it/

System of assessment and verification of constancy of performance of the product: EXC2 Notified factory production control certification body No. 1381 performed the initial inspection of the manufacturing plant and of factory production control and the continuous surveillance, assessment, and evaluation of factory production control and issued the certificate of conformity of the factory production control Stephanie Berry Date: June 29, 2015 Director of Product Operations Trylon

[email protected] www.trylon.com 7

MOUNT CALCULATION

EXAMPLE

Antenna/MW Standoff Mount (0.5m Pipe)

With Medium Backings Kit # 4.927.0108.001

21 South Field Drive, PO Box 186 Design Code: BS8100

Elmira, Ontario, Canada N3B 2Z6

519-669-5421 (ph), 519-669-8912 (fx)

INPUT VALUES

1) SITE AND TOWER PARAMETERS

Wind Speed* 24.0 m/s

Tower Height 60.0 m

Antenna Elevation* 60.0 m

Site Altitude 100 m

2) ANTENNA

Antenna Type* r (Flat,Round)

Height of Antenna* 1.50 m

Width of Antenna* 0.50 m

Weight of Antenna* 50.0 kg

3) MOUNT OPTIONS

Number of Mounting Angles* 1 (1 or 2)

OK!

Length of Horizontal Pipe* 0.5 m (0.5, 1, 2 or 3)

Backing* Medium (Medium, Small)

4) MAX ALLOWABLE ANTENNA DEFLECTION

Relative to tower/wall* 5.00 mm

SUMMARY of RESULTSDESIGNED TO: 24M/S WIND SPEED

(1) 1.5M x0.5M ANTENNAResults Capacity

Vertical Pipe Bend Check 500mm LONG x 76mm OD x 6mm THK [345MPa] 21.71 MPa 310.28 MPaPASS [1.7%]

Horizontal Angle Bend Check 64mm x 64mm x 6mm, 613mm LONG [300MPa] 228.79 MPa 273.04 MPaPASS [83.8%]

Backing Channel Bend Check 260mm LONG x 44mm WIDE x 57mm DEEP x 5mm THK [300MPa] 111.15 MPa 273.04 MPaPASS [40.7%]

Backing Rod Combined Shear & Tension CheckPASS [8.2%]

Tower Leg Reactions Per Backing Horizontal 1.35 kNVertical 0.63 kN

Torsional Moment 0.52 kN.mTotal mount Deflection 0.55 mm PASS

APPROX. MOUNT WEIGHT: 0.60 kN (Antenna and tower connection included)

Assumptions: - Areas calculated usings BS8100 guidelines - Quality Class: A - Design based on 50 year return basic wind speed - Terrain Category: III (Typ UK farmland) - Environment Conditions: Adjacent to Main Road - Checked Design for Member Stresses - Usage: Broadcasting - S values are calculated using std tables/formulas - Antenna centrally located on vertical Pipe - Atmospheric environment assumed to by Type (a) as per BS8100, cl. 3.1.1

ELEVATION VIEW

PLAN VIEW

[email protected] www.trylon.com 8

ANTENNA/MW STANDOFF

MOUNTS

NOTES: 1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Mount assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See pages 33, 34, and 35 for Installation Drawings

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL

Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s

Length of Pipe (0.5m) - Round / Flat

Allowable Antenna Loading

1.41 m2 1.23 m2 1.08 m2 1.26 m2 1.10 m2 0.96 m2

0.61 m2 0.52 m2 0.44 m2 0.54 m2 0.45 m2 0.39 m2

Length of Pipe (1m) - Round / Flat

3.95 m2 2.45 m2 2.15 m2 2.52 m2 2.19 m2 1.92 m2

1.24 m2 1.05 m2 0.89 m2 1.08 m2 0.91 m2 0.78 m2

Length of Pipe (2m) - Round / Flat

2.74 m2 2.39 m2 2.10 m2 2.46 m2 2.14 m2 1.87 m2

1.20 m2 1.02 m2 0.87 m2 1.05 m2 0.89 m2 0.76 m2

Length of Pipe (3m) - Round / Flat

2.67 m2 2.33 m2 2.05 m2 2.40 m2 2.08 m2 1.82 m2

1.17 m2 0.99 m2 0.85 m2 1.02 m2 0.86 m2 0.74 m2

Kit # Description Qty Weight (kg) 4.927.0108.001 MW Standoff Mount (76mm OD x 0.5m Pipe) Each 13.2 kg

4.927.0103.001 MW Standoff Mount (76mm OD x 1m Pipe) Each 24.5 kg

4.927.0103.002 MW Standoff Mount (76mm OD x 2m Pipe) Each 36.0 kg

4.927.0103.003 MW Standoff Mount (76mm OD x 3m Pipe) Each 47.7 kg

4.927.0103.101 MW Standoff Mount (Without Pipe) Each 14.7 kg

[email protected] www.trylon.com 9

YOKE BRACKET MOUNT

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL

Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading per Pipe

3.93 m2 3.25 m2 2.73 m2 3.38 m2 2.79 m2 2.34 m2

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See pages 36 and 37 for Installation Drawings

Kit # Description Qty Weight (kg)

4.927.0102.001 2-Pipe Yoke Bracket Mount (60mm OD x 3m Pipe) Each 77.0 kg

4.927.0102.101 2-Pipe Yoke Bracket Mount (Without Pipe) Each 44.9 kg

[email protected] www.trylon.com 10

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL

Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading per Pipe

2.93 m2 2.93 m2 2.93 m2 2.93 m2 2.93 m2 2.93 m2

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top wall.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 38 for Installation Drawing

LIGHT DUTY WALL MOUNT

ASSEMBLY

Kit # Description Qty Weight (kg)

4.954.0012.001 Solid Light Wall Mount Assembly (60mm OD x 1m Pipe) Each 13.7 kg

4.954.0012.002 Brick Light Wall Mount Assembly (60mm OD x 1m Pipe) Each 11.7 kg

[email protected] www.trylon.com 11

WALL MOUNT ASSEMBLY

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL

Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading

16.75 m2 13.88 m2 11.69 m2 14.47 m2 11.96 m2 10.05 m2

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top wall.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 39 for Installation Drawing

Kit # Description Qty Weight (kg)

4.954.0010.001 Solid Wall Mount Assembly (76mm OD x 2m Pipe) Each 60.0 kg

4.954.0010.002 Brick Wall Mount Assembly (76mm OD x 2m Pipe) Each 54.0 kg

[email protected] www.trylon.com 12

CORNER MOUNT ASSEMBLY

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL

Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading

4.87 m2 4.27 m2 3.75 m2 4.38 m2 3.81 m2 3.34 m2

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top wall.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 40 for Installation Drawing

Kit # Description Qty Weight (kg)

4.954.0011.001 Solid Wall Corner Mount Assembly (76mm OD x 2m Pipe) Each 37.0 kg

4.954.0011.002 Brick Wall Corner Mount Assembly (76mm OD x 2m Pipe) Each 35.0 kg

[email protected] www.trylon.com 13

PIPE EXTENSION ASSEMBLY

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Mount assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) Assumed 0.2m Clamp Distance and 2m Extension Pipe.6) See page 41 for Installation Drawing

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL

Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading

4.71 m2 3.90 m2 3.27 m2 4.04 m2 3.34 m2 2.81 m2

Kit # Description Qty Weight (kg)

4.927.0100.001 Pipe Extension Assembly Each 6.0 kg

[email protected] www.trylon.com 14

3-PIPE 3-SECTOR SPINE

MOUNT

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL

Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading per Pipe

2.29 m2 2.29 m2 2.29 m2 2.29 m2 2.29 m2 2.29 m2

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See pages 42 and 43 for Installation Drawings

Kit # Description Qty Weight (kg)

4.927.0104.001 3-Pipe, 3-Sector Spine Mount (76mm OD x 2m Pipe) Each 156.0 kg

4.927.0104.101 3-Pipe, 3-Sector Spine Mount (Without Pipe) Each 88.4 kg

[email protected] www.trylon.com 15

6-PIPE 3-SECTOR SPINE

MOUNT

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL

Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading

1.11 m2 1.11 m2 1.11 m2 1.11 m2 1.11 m2 1.11 m2

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 25.0 kg antenna weight per square meter of antenna area.5) See pages 44 and 45 for Installation Drawings

Kit # Description Qty Weight (kg)

4.927.0105.001 6-Pipe, 3-Sector Spine Mount (60mm OD x 1.5m Pipe) Each 223.0 kg

4.927.0105.101 6-Pipe, 3-Sector Spine Mount (Without Pipe) Each 179.0 kg

[email protected] www.trylon.com 16

POLE RING STANDOFF

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL

Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading per Pipe

5.80 m2 5.28 m2 4.84 m2 5.38 m2 4.89 m2 4.48 m2

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See pages 46 and 47 for Installation Drawings

Kit # Description Qty Weight (kg)

4.927.0101.001 Pole Ring Standoff (76mm OD x 2m Pipe) Each 158.0 kg

4.927.0101.101 Pole Ring Standoff (Without Pipe) Each 88.4 kg

[email protected] www.trylon.com 17

2-LEVEL POLE RING

STANDOFF

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL

Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading per Pipe

8.43 m2 6.97 m2 5.85 m2 7.23 m2 5.98 m2 5.02 m2

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 48 for Installation Drawing

Kit # Description Qty Weight (kg)

4.927.0106.001 2-Level Pole Ring Standoff (76mm OD x 4m Pipe) Each 316.0 kg

[email protected] www.trylon.com 18

2L 6P POLE RING STANDOFF

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL

Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading per Pipe

9.22 m2 7.62 m2 6.40 m2 7.91 m2 6.54 m2 5.49 m2

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 49 for Installation Drawing

Kit # Description Qty Weight (kg)

4.927.0107.001 2L 6P Pole Ring Standoff (60mm OD x 3.5m Pipe) Each 397.0 kg

[email protected] www.trylon.com 19

BULK PIPE

Kit # Description Qty Weight (kg) 5.960.0191.001 60m OD HSS Pipe x 0.5m long Each 2.8 kg

5.960.0191.002 60m OD HSS Pipe x 1m long Each 5.7 kg

5.960.0191.003 60m OD HSS Pipe x 2m long Each 11.4 kg

5.960.0191.004 60m OD HSS Pipe x 3m long Each 17.1 kg

5.960.0191.005 60m OD HSS Pipe x 2.5m long Each 8.6 kg

5.960.0191.006 60m OD HSS Pipe x 3.5m long Each 20.0 kg

5.960.0191.007 60m OD HSS Pipe x 2.5m long Each 14.3 kg

5.960.0190.001 76m OD HSS Pipe x 1m long Each 11.4 kg

5.960.0190.002 76m OD HSS Pipe x 2m long Each 23.0 kg

5.960.0190.003 76m OD HSS Pipe x 3m long Each 34.4 kg

5.960.0190.004 76m OD HSS Pipe x 4m long Each 34.4 kg

5.960.0190.005 76m OD HSS Pipe x 0.5m long Each 46.0 kg

5.960.0190.006 76m OD HSS Pipe x 2.5m long Each 5.8 kg

5.960.0193.001 88.9m OD HSS Pipe x 0.5m long Each 5.9 kg

5.960.0193.002 88.9m OD HSS Pipe x 1m long Each 11.9 kg

5.960.0193.003 88.9m OD HSS Pipe x 1.5m long Each 17.7 kg

5.960.0193.004 88.9m OD HSS Pipe x 2m long Each 23.6 kg

5.960.0193.005 88.9m OD HSS Pipe x 2.5m long Each 29.6 kg

5.960.0193.006 88.9m OD HSS Pipe x 3m long Each 35.5 kg

5.960.0193.007 88.9m OD HSS Pipe x 3.5m long Each 41.5 kg

5.960.0193.008 88.9m OD HSS Pipe x 4m long Each 47.2 kg

[email protected] www.trylon.com 20

LIGHT DUTY ROOFTOP BALLAST

MOUNT

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810020m Roof Height AGL

Wind Speed 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading 0.48 m2 0.35 m2 0.26 m2

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at 3.0m ARL.3) Terrain Category V; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 50 for Installation Drawing

Kit # Description Qty Weight (kg)

4.951.0012.001 Light Duty Roof Ballast Mount Each 45.5 kg

[email protected] www.trylon.com 21

SINGLE PIPE ROOF BALLAST

MOUNT

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810020 m Roof Height AGL

Wind Speed 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading 2.61 m2 2.13 m2 1.76 m2

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at 3.0m ARL.3) Terrain Category V; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 51 for Installation Drawing

Kit # Description Qty Weight (kg)

4.951.0010.001 Single Pipe Roof Ballast Mount Each 205.0 kg

[email protected] www.trylon.com 22

DOUBLE PIPE ROOF BALLAST

MOUNT

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antennas assumed at 3.0m ARL.3) Terrain Category V; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 52 for Installation Drawing

MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810020m Roof Height AGL

Wind Speed 20 m/s 22 m/s 24 m/s

Allowable Antenna Loading 4.12 m2 3.39 m2 2.82 m2

Kit # Description Qty Weight (kg)

4.951.0011.001 Double Pipe Roof Ballast Mount Each 297.0 kg

[email protected] www.trylon.com 23

• Rhino Tile is fi xed together using interlocking mechanism, no need for taping together

• Can be used inside or outside for temporary or semi-permanent applications

• Edging strip can be purchased separately and provide non-trip access where needed. Edging strip come in male or female formats

• Easy to cut to size with jigsaw or stanley knife

Guidelines for Use

Rhino Tile InformationMaterial PVC Tile

Size 500mm x 500mm 14 mmWeight 1.7kg per tileColor Black (Recycled) from stock

Fire & Heat Resistance UL 94 V-2Slip Resistance BS EN 7188

Recyclability 100% recycled and recyclableAnixter Electrical and Electronic Solutions Part Numbers

SMMATM5000M5000000 Black Rhino Tile PVC-FRSMTILEM5000003 Yellow Rhino edging strip (male) SMTILEM5000004 Yellow Rhino edging strip (female)

Why Choose Rhino Tile• Interlocking mechanism, no need for tape• Extremely durable, absorbing impact and

shock• Perfect for heavy foot traffi c• Easy to cut if required• 100% Recycled• Easy to clean & can be used over and over

again

OPTIONAL ROOFMOUNT

ACCESSORY

[email protected] www.trylon.com 24

STEP BOLT ASSEMBLY

Kit # Description Qty Weight (kg)

4.918.0080.001 Step Bolt Assembly Each 3.0 kg

NOTES:1) See page 53 for Installation Drawing

[email protected] www.trylon.com 25

4-HOLE FEEDER BRACKET

NOTES:1) See page 54 for Installation Drawing

Kit # Description Qty Weight (kg)

4.939.0090.001 4-Hole Feeder Bracket Each 3.0 kg

[email protected] www.trylon.com 26

6-HOLE FEEDER BRACKET

NOTES:1) See page 55 for Installation Drawing

Kit # Description Qty Weight (kg)

4.939.0091.001 6-Hole Feeder Bracket Each 3.4 kg

[email protected] www.trylon.com 27

GANTRY POLES

NOTES:.1) See page 56 for Installation Drawing

Kit # Description Qty Weight (kg)

5.939.1500.003 114 OD x 6 length 1.5m Each 69.1 kg

5.939.1500.004 114 OD x 6 length 3.0m Each 132.9 kg

[email protected] www.trylon.com 28

FIXED CROSSOVER ASSEMBLY

NOTES:1) See pages 57 and 58 for Installation Drawing

Kit # Description Qty Weight (kg)

4.960.0001.001 Fixed Crossover Assembly (60mm to 60mm) Each 4.7 kg

4.960.0002.001 Fixed Crossover Assembly (89mm to 89mm) Each 6.0 kg

4.960.0003.001 Fixed Crossover Assembly (89mm to 76mm) Each 6.0 kg

4.960.0004.001 Fixed Crossover Assembly (60mm to 89mm) Each 6.0 kg

4.960.0005.001 Fixed Crossover Assembly (76mm to 76mm) Each 6.0 kg

4.960.0006.001 Fixed Crossover Assembly (60mm to 76mm) Each 6.0 kg

[email protected] www.trylon.com 29

UNIVERSAL FIXED CROSSOVER

ASSEMBLY

NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 59 for Installation Drawing

Kit # Description Qty Weight (kg)

4.960.0007.001 Universal Fixed Crossover Assembly Each 10.9 kg

[email protected] www.trylon.com 30

2-WAY RRU MOUNT

Kit # Description Qty Wt

4.927.0110.001 2-way RRU Mount Kit (6.0 cm OD to 11.5 cm OD, 7.6 cm to 10.1 cm angle) Each 13.5 kg

NOTES:1) Can be used on Ericsson RRU Models, RRU S11, RRU S01, RRUL, RRUA2. Please inquire for all other RRU Models 2) See page 60 for Installation Drawing

[email protected] www.trylon.com 31

3-WAY RRU MOUNT

Kit # Description Qty Wt

4.927.0111.001 3-way RRU Mount Kit (6.0 cm OD to 11.5 cm OD, 7.6 cm to 10.1 cm angle) Ea 18.6 kg

NOTES: 1) Can be used on Ericsson RRU Models, RRU S11, RRU S01, RRUL, RRUA2. Please inquire for all other RRU Models2) See page 61 for Installation Drawing

[email protected] www.trylon.com 32

4-WAY RRU MOUNT

Kit # Description Qty Wt

4.927.0109.001 4-way RRU Mount Kit (6.0 cm OD to 11.5 cm OD, 7.6 cm to 10.1 cm angle) Ea 23.5 kg

NOTES:1) Can be used on Ericsson RRU Models, RRU S11, RRU S01, RRUL, RRUA2. Please inquire for all other RRU Models 2) See page 62 for Installation Drawing

[email protected] www.trylon.com 33

ANTENNA/MW STANDOFF MOUNT

INSTALLATION

[email protected] www.trylon.com 34

ANTENNA/MW STANDOFF MOUNT

INSTALLATION

[email protected] www.trylon.com 35

ANTENNA/MW STANDOFF MOUNT WITHOUT PIPE

INSTALLATION

[email protected] www.trylon.com 36

YOKE BRACKET MOUNT

INSTALLATION

[email protected] www.trylon.com 37

YOKE BRACKET MOUNT WITHOUT PIPE

INSTALLATION

[email protected] www.trylon.com 38

LIGHT WALL MOUNT

INSTALLATION

[email protected] www.trylon.com 39

WALL MOUNT INSTALLATION

[email protected] www.trylon.com 40

CORNER MOUNT INSTALLATION

[email protected] www.trylon.com 41

PIPE EXTENSION ASSEMBLY

INSTALLATION

[email protected] www.trylon.com 42

3-PIPE 3-SECTOR SPINE MOUNT

INSTALLATION

[email protected] www.trylon.com 43

3-PIPE 3-SECTOR SPINE MOUNT WITHOUT PIPE

INSTALLATION

[email protected] www.trylon.com 44

6-PIPE 3-SECTOR SPINE MOUNT

INSTALLATION

[email protected] www.trylon.com 45

6-PIPE 3-SECTOR SPINE MOUNT WITHOUT PIPE

INSTALLATION

[email protected] www.trylon.com 46

\Sales\UK Product\Trylon UK Accessory CAD Installation Drawings\4.927.0101.001 POLE RING STANDOFF.dwg, 8/10/2015 9:47:05 AM, cameronc

POLE RING STANDOFF

INSTALLATION

[email protected] www.trylon.com 47

POLE RING STANDOFF WITHOUT PIPE

INSTALLATION

[email protected] www.trylon.com 48

\Sales\UK Product\Trylon UK Accessory CAD Installation Drawings\4.927.0106.001 2-LEVEL, 3-PIPE POLE RING STANDOFF.dwg, 8/10/2015 9:58:42 AM, cameronc

2-LEVEL POLE RING STANDOFF

INSTALLATION

[email protected] www.trylon.com 49

\Sales\UK Product\Trylon UK Accessory CAD Installation Drawings\4.927.0107.001 2-LEVEL, 6-PIPE POLE RING STANDOFF.dwg, 8/10/2015 10:02:34 AM, cameronc

2L 6P POLE RING STANDOFF

INSTALLATION

[email protected] www.trylon.com 50

LIGHT DUTY ROOF BALLAST MOUNT

INSTALLATION

[email protected] www.trylon.com 51

SINGLE PIPE ROOF BALLAST MOUNT

INSTALLATION

[email protected] www.trylon.com 52

DOUBLE PIPE ROOF BALLAST MOUNT

INSTALLATION

[email protected] www.trylon.com 53

STEP BOLT ASSEMBLY

INSTALLATION

[email protected] www.trylon.com 54

4-HOLE FEEDER BRACKET INSTALLATION

[email protected] www.trylon.com 55

6-HOLE FEEDER BRACKET INSTALLATION

[email protected] www.trylon.com 56

GANTRY POLES INSTALLATION

[email protected] www.trylon.com 57

FIXED CROSS OVER ASSEMBLIES INSTALLATION

[email protected] www.trylon.com 58

FIXED CROSS OVER ASSEMBLIES INSTALLATION

[email protected] www.trylon.com 59

UNIVERSAL FIXED CROSS OVER ASSEMBLIES

INSTALLATION

[email protected] www.trylon.com 60

2-WAY RRU MOUNT

INSTALLATION

[email protected] www.trylon.com 61

3-WAY RRU MOUNT

INSTALLATION

[email protected] www.trylon.com 62

4-WAY RRU MOUNT

INSTALLATION

[email protected] www.trylon.com 63

NOTES

[email protected] www.trylon.com 64

TRYLON ALSO OFFERS

SuperTitan KD Specifi ca ons• Brand New Packaging Process

• Minimize freight costs (weight & dimensions)• Minimizes storage space• Improved economic footprint

• All members are hot-dip galvanized throughout• Designed to conform with CE standard• Maximum height: 57.9 meters• Sec on height: 3.0 meters

The SuperTitan KD is a modular tower that can be built up to 57.9 meters high. Consis ng of 21 standard sec ons, each 3.0 meters high, this modular system can be confi gured to create towers of varying heights and loading capaci es.

SuperTitan MAX Specifi ca ons

• Tallest stock product tower off ered• Ships from Trylon• Designed to conform with CE Standards• Maximum height: 76.5 meters• Sec on height: 5.8 meters

Designed using the same basic modular confi gura on as the SuperTitanKD model, the SuperTitan MAX features a wide range of heights and op ons for increasing strength and capacity. The SuperTitan MAX is shipped in 5.8 meters sec ons which can be assembled to a maximum height of 76.5 meters, making it Trylon’s tallest self-suppor ng stocked tower.

www.trylon.com

TM, ®, ©, LOGOS, STYLIZED NAMES ARE TRADEMARKS OF TRYLON MANUFACTURING COMPANY LTD. © 2016 PRINTED IN CANADA

For further informa on please call your local Anixter Electrical and

Electronic Solu ons representa ve. Contact informa on can be found

on page 2 of this brochure.