ILN, ILNC ILN, ILNC Series DN discharge nozzle [mm] DN Impeller [mm] Impeller Hydraulics Auxiliary priming system ---: without auxiliary system S: with priming pump E: with ejector Coupling spacer for sizes ≥ 300/330 ---: without D: with In Line vertical pumps ILN single suction ILN double suction ILNC sizes 65/… to 250/... sizes 300/… all sizes 1. Fields of Application Suitable for a wide variety of offshore services to pump clean or slightly loaded liquid (water, sea water...): Cooling of main and auxiliary engines Bilge Ballast Fire fighting Cargo tanks cleaning Brine circulation Deck washing Cooling and air conditioning ILN-ILNC Pumps can be used as well for onshore applications, specially suited where there are space constraints For pumping hydrocarbons please contact KSB ITUR since special material variant may be required. 2. Operating Data ILN ILNC 50Hz 60Hz 50Hz 60Hz Capacity, max m 3 /h 3100 3700 370 447 Head, max m 112 162 112 161 Operating temp, max. ºC 70 70 70 70 Operating temp, min. ºC -20 -20 -20 -20 Operating pressure, max. bar 16 16 16 16 Operating speed, max rpm 3000 3600 3000 3600 For any specific application beyond these limits, please consult KSB ITUR. All data given in this document are for fully standard construction. 3. Design Vertical, volute pump casing with in line suction and discharge flanges. Single stage, closed impeller with single or double suction depending on pump size (check table below). Equipped with renewable wear rings in pump casing and cover. Pump is for vertical installation. ILN pump size Impeller type 65/--- up to 250/--- single suction ≥ 300/--- double suction ILNC pump size Impeller type all single suction When an S letter is added to the ILN and ILNC series, it means that the pump has an automatic priming system via an auxiliary liquid ring priming pump (see point 15.1). When an E letter is added to the ILN and ILNC series, it means that the pump has an automatic priming system via an auxiliary Ejector (see point 15.2) 4. Designation ILN (D) (S) 100 / 250 B Type series booklet CTI-2600/04 [04-2017]

Upload: others

Post on 15-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

ILN, ILNC Series

Serie: INVCP, INVCN

DN discharge nozzle [mm]

DN Impeller [mm]

Impeller Hydraulics

Auxiliary priming system ---: without auxiliary system

S: with priming pump E: with ejector

Serie: INVCP, INVCN

Coupling spacer for sizes ≥ 300/330 ---: without

D: with

Serie: INVCP, INVCN

In Line vertical pumps

ILN single suction ILN double suction ILNC

sizes 65/… to 250/... sizes ≥ 300/… all sizes

1. Fields of Application

Suitable for a wide variety of offshore services to pump clean or slightly loaded liquid (water, sea water...):

Cooling of main and auxiliary engines

Bilge

Ballast

Fire fighting

Cargo tanks cleaning

Brine circulation

Deck washing

Cooling and air conditioning

ILN-ILNC Pumps can be used as well for onshore applications, specially suited where there are space constraints

For pumping hydrocarbons please contact KSB ITUR since special material variant may be required.

2. Operating Data

ILN ILNC

50Hz 60Hz 50Hz 60Hz

Capacity, max m3/h 3100 3700 370 447

Head, max m 112 162 112 161

Operating temp, max. ºC 70 70 70 70

Operating temp, min. ºC -20 -20 -20 -20

Operating pressure, max. bar 16 16 16 16

Operating speed, max rpm 3000 3600 3000 3600

For any specific application beyond these limits, please consult KSB ITUR. All data given in this document are for fully standard construction.

3. Design

Vertical, volute pump casing with in line suction and discharge flanges. Single stage, closed impeller with single or double suction depending on pump size (check table below). Equipped with renewable wear rings in pump casing and cover. Pump is for vertical installation.

ILN pump size Impeller type

65/--- up to 250/--- single suction

≥ 300/--- double suction

ILNC pump size Impeller type

all single suction

When an S letter is added to the ILN and ILNC series, it means that the pump has an automatic priming system via an auxiliary liquid ring –priming pump (see point 15.1).

When an E letter is added to the ILN and ILNC series, it means that the pump has an automatic priming system via an auxiliary Ejector (see point 15.2)

4. Designation ILN (D) (S) 100 / 250 B

Type series booklet CTI-2600/04 [04-2017]

Page 2: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

- 2 -2 ILN, ILNC

2

5. Materials

Material variant

Denomination Ref. 01 03 26 (1)

Volute casing 102 JL1040 RG-5 AL-60

Pump cover 161

Shaft 210 AISI-316L (2) AISI-316L (2) AISI-316L (3)(4)

Impeller 230 SN10 AL-60 AL-60

Pump pedestal 181 JL1040 (5)

Wear rings 502 RG-7

Mechanical Seal 433 BQ1EGG-WA / Q1Q1VGG (6)(7)

(1) Material variant not available in following sizes: ILN 65/315, 80/315, 100/315, 80/400, 100/400, 125/400 and 100/250 ILNC 65/315, 80/315, 100/315 and 100/250

(2) AISI-329 for ILN 80/160 (3) AISI-329 for ILN 80/160 and 80/250

(4) AISI-329 for ILNC 40/250, 50/200, 65/160 and 80/160 sizes with motor frames ≥ 200L

(5) F-111 for ILN 200/330 and 250/330 (6) For ILN 200/330 and 250/330 sizes Q1Q1EGG / Q1Q1VGG

(7) Materials codes according to DIN 24960

Material key

Code Denomination Other equivalents

JL1040 Grey cast iron EN 1561: GJL-250 (Former GG-25)

F-111 Carbon steel C-15

AISI-316L Hot rolled chrome nickel molybdenum steel

1.4435

AISI-329 Stainless steel A276-S31803

AISI-431B Chrome nickel steel 1.4057

AL-60 Nickel aluminium bronze EN 1982: CC333G / Cu Al10 Fe5 Ni5-C

RG-7 Bronze CuSn5ZnPb5-C

SN-10 Bronze CuSn10-C-GS

6. Components

6.1 Shaft Seal

Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard.

6.2 Drive

As standard, surface cooled IP-55 IEC frame electric motor with standard construction IM 3011 (IM V1).

6.3 Bearings / Lubrication

The ILN series with single suction (see point 3) impeller incorporates a bearing bracket with two bearings greased for life.

The ILN series with double suction (see point 3) impeller incorporates one bearing greased for life and a friction bearing bush lubricated by pumped media.

The ILNC series (compact) has a bearing bracket with one ball bearing greased for life.

6.4 Coupling

The ILN series with single suction impeller (see point 3) incorporates a flexible coupling with a spacer.

The ILN series with double suction impeller (see point 3) incorporates a flexible coupling without spacer. For this case the option of coupling with spacer is available (option marked with D letter).

The ILNC series (compact design) includes a rigid coupling.

Coupling Guard: Metallic protections are supplied as standard.

7. Product information according to Regulation

547/2012 (for waterpumps with a maximum shaft

power of 150 kW) based on Directive 2009/125/EC

“Ecodesign Directive”

Minimum efficiency index (MEI) see the name plate

The benchmark for most efficient water pumps is MEI ≥ 0,70

Construction year: see name plate

Manufacturer name or plant mark, commercial registry number and manufacturing place: see datasheet and order documentation

Type and product size indications: see name plate

Hydraulic efficiency (%) with a trimmed impeller: see datasheet

Pump performance curves, efficiency curves included: see the performance curve from the documentation

The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum

Page 3: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

- 3 -3 ILN, ILNC

3

efficiency index (MEI) is based on the full impeller diameter.

The operation of this water pump with variable duty points may be more efficient and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system

Information on dismantling, recycling and disposal, see chapter 3.3

Information on benchmark efficiency and benchmark efficiency graph for MEI = 0,7 (0,4) for

the pump based on the model shown in the figure is available on:

http://www.europump.org/efficiencycharts

8. Certification

Certified quality management according to ISO-9001

Page 4: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

- 4 -4 ILN, ILNC

4

9. Selection charts

ILN 50 Hz

8

16

24

32

40

48

56

64

72

80

88

96

104

112

120

5010 100 500 1000 2000 [m3/h]

[m]

4000

ILN 60 Hz

16

32

48

64

80

96

112

128

[m]

144

160

176

5010 100 500 1000 2000 [m3/h]4000 5000

Page 5: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

- 5 -5 ILN, ILNC

5

ILNC 50 Hz

8

16

24

32

40

48

56

64

72

80

88

96

104

112

120

[m]

50 10 50 100 400 [m3/h]

ILNC 60 Hz

16

32

48

64

80

96

112

128

[m]

144

160

176

50 10 50 100 500 [m3/h]

Page 6: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

- 6 -6 ILN, ILNC

6

10. Benefits at a glance

ILN Series

Watertight bearings greased for life, do not need regreasing either maintenance

Long term seal: self vented wide mechanical seal box

Service friendly casing

wear ring: no wear on the casing / cover

Liquid suction and discharge IN-LINE for minimum distance and space optimization

Innovative base plate High pump stability; allows rotating the pump with the base each 90º (up to size ILN-150/400 included)

Confined O-ring gasket for total tightness

Little floor space required thanks to

vertical design

Easy motor mounting and hydraulic rotor change

thanks to flexible coupling

with spacer

Page 7: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

- 7 -7 ILN, ILNC

7

ILNC Series

Over dimensioned bearings

in pump side allows use of standard motor and reliable long service

Liquid suction and discharge IN-LINE for minimum distance and space optimization

Confined O-ring

gasket for total tightness

Little floor space required thanks to

vertical and compact

design

Innovative base plate High pump stability; allows rotating the pump with the base each 90º

Long term seal: self vented wide mechanical seal box

Service friendly casing

wear ring: no wear on the casing / cover

Page 8: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

- 8 -8 ILN, ILNC

8

11. Technical data

ILN Series

ILN PUMP SIZE U

nits

65/1

60B

80/1

60B

65/2

50B

80/2

00B

80/2

50B

100/2

50B

125/2

50A

125/2

50B

65/3

15B

80/3

15B

100/3

15B

80/4

00N

100/4

00B

125/3

15B

125/4

00B

150/4

00B

150/2

50R

150/3

15R

200/3

30R

250/3

30R

300/3

30B

400/4

30B

General

Impeller outlet width mm 21 33 14 25 20 28 38 37 12 17,5 23,5 9 17 30,5 24 33,5 49 40 54 72 45 68

Max. & min. Impeller Ø

mm See individual curve

Shaft Ø

Under ball bearings mm 30 40 55 40 50 55 60

At coupling mm 24 32 42 28 38 45 50 60

Bearings (1)

Ball bearings (pump side)

6306 3308 6211 3308 3312 (2) (2)

Ball bearings (motor side)

6306 6308 6211 6308 6310 6211 3212

Motor frame See point 12

P/n drive rating (3) kW/rpm 0,0137 0,0434 0,1067 0,0297 0,0754 0,1317 0,1841

Shaft seal

Type Single Mechanical seal acc. to EN 12756 (DIN 24960)

Size Ø mm 28 38 48 38 48 53 58 65

(1) All bearings type 2RS C3

(2) Friction bearing bush instead of ball bearing

(3) For AISI-316. Consult KSB ITUR for other shaft materials

ILNC Series

ILNC PUMP SIZE

Units

32/1

60A

32/1

60B

32/2

00A

32/2

00B

32/2

50B

40/1

60A

40/1

60B

40/2

50A

40/2

50B

50/2

00A

50/2

00B

65/1

60B

80/1

60B

65/2

50B

80/2

00B

80/2

50B

100/2

50B

125/2

50A

125/2

50B

65/3

15B

80/3

15B

100/3

15B

General

Impeller outlet width mm 5 6 4 6 5 7 12 4,5 8 7 12 21 33 15 25 20 28 38 37 12 17,5 23,5

Max. & min. Impeller Ø mm See individual curve

Shaft Ø

Under ball bearing mm 45 50 55

Bearings (1)

Ball bearing 6309 6310 or 3310 (2) 6310 6211

Motor frame See point 12

P/n drive rating (2) kW/rpm 0,005 0,0137 0,0434

Shaft seal

Type Single Mechanical Seal acc. to EN 12756 (DIN 24960)

Size Ø mm 28 38

(1) All bearings type 2RS C3

(2) 6310 for motor frames ≤ 132. Otherwise 3310

(3) For AISI-316. Consult KSB ITUR for other shaft materials

Page 9: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

9

12. Cross drawings

ILN PUMP

SIZE

DRAWING

Cross

drawing 1

Cross

drawing 2

Cross

drawing 3

Cross

drawing 4

Cross

drawing 5

65-160 X

65-250 X

65-315 X

80-160 X

80-200 X

80-250 X

80-315 X

80-400 X

100-250 X

100-315 X

100-400 X

125-250 X

125-315 X

125-400 X

150-250 X

150-315 X

150-400 X

200-330 X

250-330 X

300-330 X

400-430 X

ILNC PUMP

SIZE

Cross

drawing 1

Cross

drawing 2

Cross

drawing 3

Cross

drawing 4

Cross

drawing 5

32-160 X

32-200 X

32-250 X

40-160 X

40-250 X

50-200 X

65-160 X

65-250 X

65-315 X

80-160 X

80-200 X

80-250 X

80-315 X

100-250 X

100-315 X

125-250 X

Page 10: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

10

CROSS DRAWING 1 FOR ILN PUMP SIZES

65-160 65-250

80-160 80-200 80-250

100-250

125-250 125-315

150-250

Cross drawing 1

Part No. Denomination

Part No. Denomination

102 Volute casing 412 O-ring

161 Pump cover 433 Mechanical seal

181 Pump pedestal 502 Wear ring

210 Shaft 507 Deflector protection

230 Impeller 840 Coupling

320 Bearing 922 Impeller nut

330 Support 932 Circlip

360 Bearing cover 940 Key

Page 11: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

11

CROSS DRAWING 2 FOR ILN PUMP SIZES

65-315

80-315 80-400

100-315 100-400

125-400

150-315 150-400

200-330

250-330

Cross drawing 2

Part No. Denomination

Part No. Denomination

102 Volute casing 412 O-ring

161 Pump cover 433 Mechanical seal

181 Pump pedestal 502 Wear ring

210 Shaft 507 Deflector protection

230 Impeller 840 Coupling

320 Bearing 922 Impeller nut

330 Support 932 Circlip

360 Bearing cover 940 Key

Page 12: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

12

CROSS DRAWING 3 FOR ILN PUMP SIZES

300-330

400-430

Cross drawing 3

Part No. Denomination

Part No. Denomination

102 Volute casing 412 O-ring

160 Cover 433 Mechanical seal

161 Pump cover 502 Wear ring

181 Pedestal 507 Deflector protector

210 Shaft 524 Shaft protecting sleeve

230 Impeller 545 Friction bearing bush

320 Bearing 922 Impeller nut

330 Support 932 Circlip

360 Bearing cover 940 Key

Page 13: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

13

CROSS DRAWING 4 FOR ILNC PUMP SIZES

32-160 32-200 32-250

40-160 40-250

50-200

65-160 65-250

80-160 80-200 80-250

100-250

125-250

Cross drawing 4

Part No. Denomination

Part No. Denomination

102 Volute casing 412 O-ring

161 Pump cover 433 Mechanical seal

181 Pump pedestal 502 Wear ring

210 Shaft 507 Deflector protection

230 Impeller 922 Impeller nut

320 Bearing 932 Circlip

330 Support 940 Key

360 Bearing cover

Page 14: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

14

CROSS DRAWING 5 FOR ILNC PUMP SIZES

65.315

80-315

100-315

Cross drawing 5

Part No. Denomination

Part No. Denomination

102 Volute casing 412 O-ring

161 Pump cover 433 Mechanical seal

181 Pump pedestal 502 Wear ring

210 Shaft 507 Deflector protection

230 Impeller 922 Impeller nut

320 Bearing 932 Circlip

330 Support 940 Key

360 Bearing cover

Page 15: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

15

13. Dimensions

ILN ELECTRIC DRIVEN PUMP

Z

≈20

0≈

H2

H1

DN s DN d

G

A

C

VIEW FROM Z

≈F

B1

B2

B3

B3

L1

L2L3 L3

≈E

S

L4

ILN

Pump DNd (1) DNs (1) C G A

PUMP PEDESTAL Motor

Frame (2) E (3) F H1 H2

B1 B2 B3 L1 L2 L3 L4 S 65/160 65 80 184 260 460 452 410 21 452 410 21 195 18 100 220 175 756,5 312

112 333

132 373

160 478

180 602

200 195 771,5 660

65/250 65 80 189 300 550 452 410 21 452 410 21 195 18 100 220 225 813 312

112 333

132 373

160 478

180 602

200 660

225 666

250 275 833 747

280 820

315 332,5 858 932

65/315 65 80 202 325 605 452 410 21 452 410 21 195 18 160 320 255 786,5 478

180 602

200 660

80/160 80 100 209 300 525 452 410 21 452 410 21 195 18 100 230 170 781,5 312

112 333

132 373

160 478

180 602

200 195 796,5 660

225 225 866,5 666

(1) EN 1092 PN 10/16 for DN < 150. Otherwise PN 10 All dimensions in mm

(2) For other motor frames consult KSB ITUR

(3) Dimension without auxiliary priming system. If priming auxiliary pump fitted (ILNS) E=F+270 / If ejector fitted (ILNE) E= F+155

Page 16: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

16

ILN

Pump

DNd

(1) DNs (1) C G A

PUMP PEDESTAL Motor

Frame (2) E (3) F H1 H2

B1 B2 B3 L1 L2 L3 L4 S

80/200 80 100 214 325 575 452 410 21 452 410 21 195 18 100 230 195 819 312

112 333

132 373

160 478

180 602

200 660

225 275 849 666

250 747

280 820

80/250 80 100 199 330 610 452 410 21 452 410 21 195 18 112 230 225 823 333

132 373

160 868 478

180 602

200 823 660

225 865 666

250 275 843 747

280 820

315 332,5 868 932

80/315 80 100 209 330 645 452 410 21 452 410 21 195 18 180 330 260 793,5 602

200 660

225 823,5 666

80/400 80 100 214 410 765 452 410 21 452 410 21 195 18 180 330 325 824,5 602

200 660

225 854,5 666

250 747

100/250 100 150 239 400 680 452 410 21 452 410 21 195 18 160 360 225 881 478

180 602

200 660

100/315 100 150 239 400 715 452 410 21 452 410 21 195 18 180 360 260 823,5 602

200 660

225 853,5 666

250 272,5 747

100/400 100 150 234 420 775 452 410 21 452 410 21 195 18 225 360 325 895 666

250 747

280 915 820

125/250 125 150 202 400 755 452 410 21 452 410 21 195 18 132 295 225 896,,5 373

160 478

180 602

200 660

225 936,5 666

125/315 125 150 217 400 755 452 410 21 452 410 21 195 18 160 255 265 975 478

180 602

200 660

225 275 1035 666

250 747

280 820

125/400 125 150 244 450 850 452 410 21 452 410 21 195 18 250 360 325 904,5 747

280 924,5 820

315 954,5 932

150/250R 150 200 284 (4)(4) (3)

450 (4) 850 (5) (5)

452 410 21 452 410 21 195 18 180 315 227,5 1031 602

200 660

225 1061 666

250 225 747

150/315 150 200 276 450 (4) 850 (5) 452 410 21 452 410 21 195 18 200 320 315 1101,5 660

225 1131,5 666

250 747

280 820

150/400 150 200 239 450 (6) 900 (7) 452 410 21 452 410 21 195 18 280 315 320 973,75 820

315 1003,8 932

(1) EN 1092 PN 10/16 for DN < 150. Otherwise PN 10 All dimensions in mm

(2) For other motor frames consult KSB ITUR

(3) Dimension without auxiliary priming system. If priming auxiliary pump fitted (ILNS) E=F+270 / If ejector fitted (ILNE) E= F+155

(4) 457 mm for material variant 00 and 01 / 455 for material variant 03

(5) 863 mm for material variant 00 and 01 / 859 mm for material variant 03

(6) 457 mm for material variant 00 and 01 / 455 mm for material variant 03

(7) 914 mm for material variant 00 and 01 / 910 mm for material variant 03

Page 17: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

17

ILN 200/330, 250/330 ELECTRIC DRIVEN PUMP

G

A

DN s DN d

C

H1

≈3

00≈

H2

Z

S

B1

B2

B3

B3

≈E

≈F

L2 L3L3

L1

L4

B4

VIEW FROM Z

ILN

Pump DNd (1) DNs (1) C G A

PUMP PEDESTAL Motor

Frame (2) E (3) F H1 H2

B1 B2 B3 B4 L1 L2 L3 L4 S 200/330 200 250 380 555 (4) 955 (5)

(6) 620 520 50 315 580 520 30 260 28 225 630 340 1310 666

250 747

280 820

315 1435 932

250/330 250 300 460 578 (6) 978 (7) (7)

600 500 50 345 590 530 30 265 28 280 680 385 1450 820

315 1515 932

(1) EN 1092 PN 10 All dimensions in mm

(2) For other motor frames consult KSB ITUR

(3) Dimension without auxiliary priming system. If priming auxiliary pump fitted (ILNS) E=F+270 / If ejector fitted (ILNE) E= F+155

(4) 563 for material variant 00 and 01 / 561 mm for material variant 03

(5) 969 mm for material variant 00 and 01 / 965 mm for material variant 03

(6) 587 mm for material variant 00 and 01 / 584 mm for material variant 03

(7) 993 mm for material variant 00 and 01 / 988 mm for material variant 03

Page 18: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

18

ELECTRIC DRIVEN DOUBLE SUCTION ILN PUMP

WITHOUT SPACER

ELECTRIC DRIVEN DOUBLE SUCTION ILN PUMP

WITH SPACER (D)

G

C

A

S

DN DN

H1

≈30

0

L1

L4

L3 L2 L3

B7

B4

B3

B6

B5

B3

B3

B2

B3

B1

s d

≈H

2

DN

G

A

C

≈H

2H

1

s DN d

≈ 3

00

B1

B5

L1

L2L3 L4

L5

B3

B3

B4

B1

B2

B3

B3

B2

S

ILN Pump DNd

(1)

DNs

(1) C G A

PUMP PEDESTAL Motor

Frame

(2)

H1 H2 B1 B2 B3 B4 B5 B6 B7 L1 L2 L3 L4 L5 S

300/330B 300 350 392 (3) 559 (4) 1113 (5) 800 700 50 289 357 700 800 845 760 45 355 --- 28 280 1100 820

315 1130 932

D 300/330B 300 350 392 (3) 559(4) 1113 (5) 800 700 50 296 350 --- --- 845 760 45 40 760 28 280 1503 820

315 1533 932

400/430B 400 500 580 (6) 703 (6) 1409 (6) 860 760 50 380 480 960 1060 730 610 60 385 --- 28 355 (7) 1534 1230

(1) EN 1092 PN 10 All dimensions in mm

(2) For other motor frames consult KSB ITUR

(3) 397 mm for material variant 00 and 01 / 395 for variant 03

(4) 568 mm for material variant 00 and 01 / 565 for variant 03

(5) 1131 mm for material variant 00 and 01 / 1125 for variant 03

(6) Dimensions stated for material variant 03. These values may be slightly different in other material variants. Consult KSB ITUR.

(7) 6 poles motor

Page 19: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

19

ILNC ELECTRIC DRIVEN PUMP

C

A

G

DN dDN s H1

≈H

2≈

20

0

Z

S

≈F

B1

B2

B3

B3

L1

L2L3 L3

L4

≈E

VIEW FROM Z

ILNC

Pump DNd (1)

DNs

(1) C G A

PUMP PEDESTAL Motor

frame (2)

E

(3) F H1 H2

B1 B2 B3 L1 L2 L3 L4 S

32/160 32 50 141 210 370 377 335 21 377 335 21 168 18 80 200 150 361,5 234

90 281

100 312

112 333

132 373

32/200 32 50 136 230 410 377 335 21 377 335 21 168 18 80 200 150 354 234

90 281

100 312

112 333

132 373

160 200 409 478

32/250 32 50 136 260 485 377 335 21 377 335 21 168 18 80 200 175 364 234

90 281

100 312

112 333

132 373

160 200 419 478

180 602

200 660

40/160 40 65 151 240 400 377 335 21 377 335 21 168 18 80 205 150 373 234

90 281

100 312

112 333

132 373

160 200 408 478

40/250 40 65 161 290 515 377 335 21 377 335 21 168 18 80 205 175 389 234

90 281

100 312

112 333

132 373

160 200 444 478

180 602

200 660

(1) EN 1092 PN 10/16 for DN < 150. Otherwise PN 10 All dimensions in mm

(2) For other motor frames consult KSB ITUR

(3) Dimension without auxiliary priming system. If priming auxiliary pump fitted (ILNCS) E=F+270 / If ejector fitted (ILNCE) E= F+155

Page 20: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

20

ILNC

Pump DNd (1) DNs (1) C G A

PUMP PEDESTAL Motor

Frame (2) E (3) F H1 H2

B1 B2 B3 L1 L2 L3 L4 S

50/200 50 65 156 260 460 377 335 21 377 335 21 168 18 80 210 150 374 234

90 281

100 312

112 333

132 373

160 200 429 478

180 602

200 660

225 225 454 666

65/160 65 80 181 260 460 377 335 21 377 335 21 168 18 80 220 150 402,5 234

90 281

100 312

112 333

132 373

160 200 437,5 478

180 602

200 660

65/250 65 80 186 300 550 377 335 21 377 335 21 168 18 90 220 175 419 281

100 312

112 333

132 373

160 200 474 478

180 602

200 660

225 225 499 666

65/315 65 80 199 325 605 377 335 21 377 335 21 168 18 132 220 200 463,5 373

160 478

180 602

200 458,5 660

80/160 80 100 206 300 525 377 335 21 377 335 21 168 18 80 230 150 427,5 234

90 281

100 312

112 333

132 373

160 200 462,5 478

180 602

200 660

225 225 507,5 666

80/200 80 100 211 325 575 377 335 21 377 335 21 168 18 90 230 150 440 281

100 312

112 333

132 373

160 200 495 478

180 602

200 660

225 225 520 666

80/250 80 100 196 330 610 377 335 21 377 335 21 168 18 90 230 175 429 281

100 312

112 333

132 373

160 200 484 478

180 602

200 660

225 225 509 666

80/315 80 100 209 330 645 377 335 21 377 335 21 168 18 160 230

200 474,25 478

180 602

200 469,25 660

225 225 524,25 666

100/250 100 150 239 400 680 377 335 21 377 335 21 168 18 132 255 175 480,5 373

160 200 525,5 478

180 602

200 660

100/315 100 150 239 400 715 377 335 21 377 335 21 168 18 160 260 200 503,75 478

180 602

200 498,75 660

225 225 553,75 666

125/250 125 150 199 40 755 377 335 21 377 335 21 168 18 132 260 175 488,5 373

160 200 533,5 478

180 602

200 660

225 225 558,5 666

(1) EN 1092 PN 10/16 for DN < 150. Otherwise PN 10 All dimensions in mm

(2) For other motor frames consult KSB ITUR

(3) Dimension without auxiliary priming system. If priming auxiliary pump fitted (ILNCS) E=F+270 / If ejector fitted (ILNCE) E= F+155

Page 21: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

21

AUXILIARY CONNECTIONS OF ILN AND ILNC PUMPS

Connection Size Function ILN ILNS/E ILNC ILNCS/E

1 ¼” G Discharge connection Connected

to pressure gauge

Connected to pressure gauge /

switch Plugged (1)

Connected to pressure switch (1)

2 ¼” G Drainage of pump casing Plugged

3 ¼” G Venting of mechanical seal chamber

Connected to suction

4 ¼” G Suction connection

Connected to vacuum gauge

and 3

Connected to vacuum gauge

Connected to 3 (2)

Plugged (2)

5 ¾” G Priming Plugged Connected to aux.

priming pump / ejector Plugged

Connected to aux. priming pump / ejector

(1) Connected to pressure gauge as well in case of ILNC/S/E purchased with pressure gauge option (2) Connected to vacuum gauge as well in case of ILNC/S/E purchased with vacuum gauge option

Page 22: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

22

14. Pump surface

As standard epoxy primer of 125 microns thickness and polyurethane finish coat of 60 microns. Final coat colour blue RAL 5010. Painted surface maximum temperature 120 ºC. Other coatings upon request.

15. Recommended stock of spare parts for two years continuous operation

Ref. Denomination

Number of pumps (including standby pumps)

1-2 3 4 5 6-7 8-9 10 and

more

--- Joints (set) 2 3 4 5 6 7 90%

433 Mechanical seal 2 3 4 5 6 7 90%

320 Bearing (set) 1 1 2 2 2 3 30%

502 Wear ring (set) 1 1 2 2 2 3 30%

507 Deflector protection 1 1 2 2 2 3 30%

524+545 Shaft protecting sleeve + friction bearing bush (1)

1 1 2 2 3 4 50%

--- Coupling flexible (set) (2) 1 1 2 2 2 3 30%

922 Impeller nut 1 1 2 2 2 3 30%

932 Circlip (set) 1 1 2 2 2 3 30%

940 Key (set) 1 1 2 2 2 3 30%

210 Pump shaft 1 1 2 2 2 3 30%

230 Impeller 1 1 2 2 2 3 30%

840 Coupling (2) 1 1 2 2 2 3 30%

(1) Only for ILN pump with double suction. (see point 3)

(2) Only for ILN pumps

Additional spare parts for priming auxiliary pump VAC (only for ILNS and ILNCS)

--- Joints (set) 2 3 4 5 6 7 90%

433 Mechanical seal 2 3 4 5 6 7 90%

940 Key 1 1 2 2 2 3 30%

20 Valve plate 1 1 2 2 2 3 30%

21 Valve 1 1 2 2 2 3 30%

230 Impeller 1 1 2 2 2 3 30%

Page 23: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

23

16. Priming systems

16.1 Priming system by auxiliary pump VAC

rear view

Mark Denomination Size To be connected by customer

1 Check valve --- ---

2 Filter --- ---

3 Electrovalve --- 220 V II + earth 50/60 Hz

4 Auxiliary priming pump --- ---

5 Discharge air/water 3/4” G (F) Leave connection free or connect to a safe drainage

6 Pressure switch (on discharge of main pump)

---

Start-up: 0,4 bar Shutdown: 70% of the operating pressure of main pump or min. of the pressure switch

The electrical control devices of the auxiliary priming pumps are not within the

scope of supply of KSB ITUR, except for the case of being expressly requested (see recommended electrical layout)

Operation

When starting up the unit, the auxiliary priming pump starts up and electrovalve

opens, beginning to extract the air existing in the suction pipe. After a period of time T1 the main pump starts up, with both operating simultaneously.

When the water reaches the main pump, the pressure increase is detected by the pressure switch, switching on a second timer, which switches off the auxiliary priming pump and the electrovalve after a period of time T2

In case a depriming happens in the facility, the pressure switch detects the pressure drop and starts up the auxiliary priming pump (the main pump remains in operation).

The start-up time (T1) of main pump depends on the volume of air to be discharged. During priming tests it must be adjusted experimentally to the minimum.

T2 shutdown time depends on any instability which may come about during start-up

The VAC auxiliary pump is not designed for continuous pumping of water without air. That is

why if T2 time is excessive, the motor of the auxiliary pump may be overheated. Thus adjust T2 to a few seconds (≈ 5 sec.) or to star-delta start-up time. In any case, the total time that the auxiliary pump works only with water shall not exceed 15 sec.

Installation

The discharge of the auxiliary pump (mark 5) should not be closed or impeded.

When the pumping liquid is water, the maximum installation height on the lowest level of the liquid must not exceed 6 m, minus the dynamic losses of the suction system.

Start-up

Bear in mind the following points when starting up:

- Check all the connections and the pipes to ensure seal tightness.

- Prime the auxiliary pump, if it is first start-up

- Check all the electrical connections.

Note Note

Note

Note

1

2

3

4

5

6

Page 24: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

24

Electrical layout recommended for the control of the auxiliary priming pump system

Mark Denomination

P1 Auxiliary priming pump

P2 Main pump

FS Buoy insufficient water

PS Pressure switch

EV Electrovalve

M Line input

T1 Timing relay with T1 delay in sec. for the main pump start-up

T2 Timing relay with T2 delay in sec. for the shutdown of auxiliary priming pump

Page 25: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

25

16.2 Priming system by KEJEC ejector

rear view

Mark Denomination Size To be connected by customer

1 Check valve --- ---

2 Suction electrovalve --- 220 V II + earth 50/60 Hz

3 Compressed air input ½ “G (F) 125 l/min of air at 5-7 bar

4 Air compressed electrovalve --- 220 V II + earth 50/60 Hz

5 KEJEC ejector --- ---

6 Ejector discharge Male 1 “ G Leave connection free or connect to a safe drainage

7 Pressure switch (on discharge of main pump)

---

Start-up: 0,4 bar Shutdown: 70% of the operating pressure of main pump or minimum of pressure switch

The electrical control devices of the auxiliary priming pumps are not within the scope of

supply of KSB ITUR, except for the case of being expressly requested (see diagram point. 0of this manual)

Operation

When starting up the unit, electrovalves open, beginning to extract the air existing in

the suction pipe. After a period of time T1 the main pump starts up, with both operating simultaneously.

When the water reaches the main pump, the pressure increase is detected by the pressure switch, switching on a second timer, which switches off electrovalves after a period of time T2

In case a depriming happens in the facility, the internal pressure switch of suction electrovalve detects the pressure drop and starts up the electrovalves (the main pump remains in operation).

The start-up time (T1) of main pump depends on the volume of air to be discharged, although for installations with short suction pipes following orientative values can be used:

Ø Suction pipe Time T1

< 50 mm 60 seconds

≤ 125 mm 120 seconds

> 125 mm 180 seconds

T2 ejector shutdown time depends on any instability which may come about during start-up and can be taken a value between 10 and 30 seconds.

Installation

The discharge of ejector (mark 6) should not be closed or impeded.

When the pumping liquid is water, the maximum installation height on the lowest level of the liquid must not exceed 6 m, minus the dynamic losses of the suction system.

Start-up

Bear in mind the following points when starting up:

- Check all the connections and the pipes to ensure seal tightness.

- Check all the electrical connections.

Note

Note

1

4

5

3

2

6

6

7

Page 26: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

26

Electrical layout recommended for the control of KEJEC ejector system

Mark Denomination

P1 Main pump

P2 Main pump

FS Buoy insufficient water

PS Pressure switch

EV 1 / 2 Electrovalves

M Line input

T1 Timing relay with T1 delay in sec. for the main pump start-up

T2 Timing relay with T2 delay in sec. for shutdown of electrovalves

Page 27: Type Series Booklet ILN, ILNC · Single mechanical seal acc. to EN 12756 (DIN 24960) is supplied as standard. 6.2 Drive As standard, surface cooled IP-55 IEC frame electric motor

ILN, ILNC

27

This page has deliberately been left blank