ts controls signal & lighting controls controls signal & lighting controls email:...
TRANSCRIPT
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 1 of 27 Release Date - 160131
Thank you for purchasing a RS / TS series traffic light control. By design, all controls are built for ease of use and years of trouble free operation and enjoyment. Manufactured in the USA, all controls are inspected and tested prior to shipment for reliability. Please refer to the following information on your RS / TS series control. What’s included: (Control Only) 1x - RS / TS Series Control 4x - Adhesive Mounting Posts Components included as a “Kit”: (Optional) 1x - Power Cord^ - (May vary slightly by color and/or length) 1x - Hook-up Wire w/ Fork Ends* * RS12 / TS12 Series Include 2x - Hook-up Wire w/ Fork Ends. ^ Power Cord Included with TS14 Series.
TABLE OF CONTENTS Page
1. General Specifications………………………………...............................................................2 2. Installation & Safety Tips…………………….…………........................................................3-6 3. RS10 Control Switch Settings…........…………………........................................................7-9 4. RS10 - Single Signal Applications……………………………..………...............................10-14 5. RS12 Control Switch Settings………....…………………..………………………...............15-18 6. RS12 - Multi-Signal Applications……….………..……….........................…....…..............19-26 7. Warranty Information & Return Form….…………………………….......................................27
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 2 of 27 Release Date - 160131
GENERAL SPECIFICATIONS (**)
Dimensions: Circuit Board Size RS10 Series - 2.75" x 3.25" (2.25" x 2.75" screw mounting) RS12 Series - 2.75" x 4.75" (2.25" x 4.25" screw mounting) AC Power: 120VAC - Fused (220VAC Optional - available by request) Fuse: RS10/12 Series - 5x20mm 250V/3A Nominal (5A Maximum) Wire Size: 16 - 22 AWG - Recommended. Output Power: RS10/RS12 - 120VAC / 150W Nominal - Each Channel (^) Time Delay: See control switch settings. Time Adjustment:* Counter-Clockwise = Slow Clockwise = Fast *Note: Time adjustment is single turn, similar to radio volume knob. Do not force beyond stopping points, as this will cause permanent damage. ^Note: Output power is compatible with both L.E.D. and incandescent lighting. **Note: General specifications are subject to change without notice.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 3 of 27 Release Date - 160131
INSTALLATION & SAFETY TIPS 1. Warning! - Never handle control unit while powered on. 2. Not intended for damp, or wet environments. 3. Only replace fuse with equivalent size and rating. 4. Remove power for bulb replacement and/or servicing of any type. 5. Do not overload outputs beyond maximum rated specification. 6. When connecting more than one incandescent bulb to a single output, divide the desired bulb wattage by 150 Watts. The result will be the number of bulbs of the desired wattage that can be used on a single output. Example: How many 40 Watt bulbs can I connect to a single output rated at 150 Watts? 150 Watts / 40 Watts = 3.75 ~ 3x - 40 Watt bulbs The number of 40 Watt bulbs that can be connected to a single output without overload is 3. 7. For AC power connection, follow the wiring diagram below.
Caution!: If you need assistance, please consult a qualified electrician.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 4 of 27 Release Date - 160131
8. If your signal is equipped with a screw-terminal block, you may reference the following diagram.
Caution!: If you need assistance, please consult a qualified electrician.
9. If your signal is not equipped with a screw-terminal block, you may reference the following diagram(s).
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 5 of 27 Release Date - 160131
Caution!: If you need assistance, please consult a qualified electrician.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 6 of 27 Release Date - 160131
CONTROL MOUNTING
1. Before mounting, be sure mounting surface area is smooth, clean, dry, & oil free. 2. Be sure mounting location allows enough clearance area around the control unit, where metal components will not come into contact with the bottom, or components on the top side of the control unit. 3. Do not route wiring underneath control unit.
RIGHT / CORRECT !!!
Caution!: If you need assistance, please consult a qualified electrician.
WRONG / INCORRECT !!!
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 7 of 27 Release Date - 160131
RS10 CONTROL SWITCH SETTINGS
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TIME DELAY
R/C Y/B G/A
(RED) (YEL) (GRN)
Time delay range: (approximate) RED - 10 seconds - 5 minutes YEL - 3 seconds - 30 seconds GRN - 10 seconds - 5 minutes
Pushbutton Input Connection:
S3 / -C and/or S4 / -C
WARNING! DO NOT USE, OR CONNECT (+AX) TERMINAL UNLESS SPECIFIED. IMPROPER CONNECTIONS MAY DAMAGE CONTROL UNIT.
Mode 1: Standard Traffic Light Sequence
(Default)
Mode 2: Vintage Light
Sequence Old Timey
Mode 3: British Traffic Light
Sequence Plessey Tin Lantern
Mode 4: Green-Yellow-Red
W.S. Darley C-811
OR
Mode 5: Green-Yellow-Red
W.S. Darley D-480
Note: Reduced bulb wattage may be required when using “Overlap” functions / settings.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 8 of 27 Release Date - 160131
RS10 CONTROL SWITCH SETTINGS (Continued)
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
Mode 6 - 8: Optional Crosswalk Push button Input
Normally Open (N.O.) - Dry contact pushbutton input (S4) cycle to "Walk" during Red / Don't Walk cycle.
Mode 6 - 8: Adjustments &
Settings
TIME DELAY Adjustment for flash count (fixed value):
Minimum - 10X Flash Count Mid Point - 20X Flash Count
R/C G/C Maximum - 30X Flash Count (DWK) (WLK)
Mode 6: Pedestrian / Crosswalk
Don't Walk-Flash
Mode 7: Pedestrian / Crosswalk Walk-Flash
Mode 8: Pedestrian / Crosswalk w/o Flash
OR
Mode 9: Flashing Red
(1/2 second - Fixed)
Mode 10: Flashing Yellow
(1/2 second - Fixed)
Note: Reduced bulb wattage may be required when using “Overlap” functions / settings.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 9 of 27 Release Date - 160131
RS10 CONTROL SWITCH SETTINGS (Continued)
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
Mode 11: Wig-Wag
Red / Yellow (1/2 second - Fixed)
Mode 12: Chasing
Sequence
Time delay range: (approximate) RED - .25 seconds - 10 seconds YEL - .25 seconds - 10 seconds GRN - .25 seconds - 10 seconds
Mode 13: Chasing
Sequence
Time delay range: (approximate) RED - 2.5 seconds - 1 minute : 30 seconds YEL - 2.5 seconds - 1 minute : 30 seconds GRN - 2.5 seconds - 1 minute : 30 seconds
Mode 14: Chasing
Sequence
Time delay range: (approximate) RED - 5 seconds - 8 minutes YEL - 5 seconds - 8 minutes GRN - 5 seconds - 8 minutes
Mode 15: Chasing
Sequence
Time delay range: (approximate) RED - 10 seconds - 16 minutes YEL - 10 seconds - 16 minutes GRN - 10 seconds - 16 minutes
Mode 16: Red / Yellow
Flashing RxR / Caution /
School Zone
For signal applications shown.
Mode 16: Adjustments &
Settings
TIME DELAY Toggle / wig-wag speed (0.25s - 1.5s) G/A (GRN) R/C (RED) / Y/B (YEL) On / Off
R/C Y/B G/A
Note: Reduced bulb wattage may be required when using “Overlap” functions / settings.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 10 of 27 Release Date - 160131
Application: RS10 - G,Y,R Signal / Chasing sequence
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 11 of 27 Release Date - 160131
Application: RS10 - PED / Crosswalk Signal
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 12 of 27 Release Date - 160131
Application: RS10 - School Zone / Caution Signaling
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 13 of 27 Release Date - 160131
Application: RS10 - RxR Signal *RxR Signal must be compatible or converted with 120VAC lighting
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 14 of 27 Release Date - 160131
Application: RS10 Simple Racing Tree
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 15 of 27 Release Date - 160131
RS12 CONTROL SWITCH SETTINGS
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
Signal #1
Time Delay
Signal #2
Time Delay
Time delay range: 10 seconds - 5 minutes (approximate) Signal #1 - adjusts signal #1 green (signal #2 - red) Signal #2 - adjusts signal #2 green (signal #1 - red)
Pushbutton Input Connection:
S3 / -C and/or S4 / -C
WARNING! DO NOT USE, OR CONNECT (+AX) TERMINAL UNLESS SPECIFIED. IMPROPER CONNECTIONS MAY DAMAGE CONTROL UNIT.
Mode 1: Standard Traffic Light Sequence
(Default)
Mode 2: Vintage Light
Sequence Old Timey
Mode 3: British Traffic Light
Sequence Plessey Tin Lantern
Mode 4: Green-Yellow-Red
W.S. Darley C-811
Mode 5: Green-Yellow-Red
W.S. Darley D-480
Note: Reduced bulb wattage may be required when using “Overlap” functions / settings.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 16 of 27 Release Date - 160131
RS12 CONTROL SWITCH SETTINGS (Continued)
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
Mode 6: Green-Yellow-Red
w/ Arrows Doghouse
Mode 7: Red / Yellow Flashing
RxR / Caution / School Zone
For signal applications shown.
Mode 7: Adjustments &
Settings
Adjust Adjust toggle / on/off A1 wig-wag speed output. (0.25s - 1.5s).
Mode 8: Chasing
Sequence
Time delay range: 0.25 - 5.0 seconds
Mode 9 - 10: Adjustments &
Settings
Green/Red
(Walk / Don't Walk) Time Delay
Adjustment for flash count (fixed value): Minimum - 10X Flash Count Mid Point - 20X Flash Count Maximum - 30X Flash Count
Mode 9 - 14: Crosswalk
Push button Input Adjustments &
Settings
Normally Open (N.O.) - Dry contact pushbutton input (S4) cycle toward "Walk" during Red / Don't Walk cycle.
Note: Reduced bulb wattage may be required when using “Overlap” functions / settings.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 17 of 27 Release Date - 160131
RS12 CONTROL SWITCH SETTINGS (Continued)
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
Pushbutton Input Connection:
S3 / -C and/or S4 / -C
WARNING! DO NOT USE, OR CONNECT (+AX) TERMINAL UNLESS SPECIFIED. IMPROPER CONNECTIONS MAY DAMAGE CONTROL UNIT.
Mode 9: Green-Yellow-Red
+ Crosswalk Walk on Green
Don't Walk-Flash
Mode 10: Green-Yellow-Red
+ Crosswalk Walk on Green
Walk-Flash
Mode 11: Green-Yellow-Red
+ Crosswalk Walk on Red
15x Don't Walk-Flash
Mode 12: Green-Yellow-Red
+ Crosswalk Walk on Red
30x Don't Walk-Flash
Mode 13: 2x Crosswalk
15x Don't Walk-Flash
Note: Reduced bulb wattage may be required when using “Overlap” functions / settings.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 18 of 27 Release Date - 160131
RS12 CONTROL SWITCH SETTINGS (Continued)
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
Mode 14: 2x Crosswalk
30x Don't Walk-Flash
Pushbutton Input Connection:
S3 / -C and/or S4 / -C
WARNING! DO NOT USE, OR CONNECT (+AX) TERMINAL UNLESS SPECIFIED. IMPROPER CONNECTIONS MAY DAMAGE CONTROL UNIT.
Mode 15: Racing Tree
Sport Sequence (S3 Input)
Sport sequence via S3 input. Normally Open (.N.O.) - Dry contact.
Mode 15: Racing Tree
Pro Sequence (S4 Input)
Pro sequence via S4 input. Normally Open (.N.O.) - Dry contact.
Mode 16: Racing Tree
Demo
Automatic sequencing of sport, and pro racing tree sequences including a quick light scan, with a pre-stage sequence between each of the three sequences.
Note: Reduced bulb wattage may be required when using “Overlap” functions / settings.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 19 of 27 Release Date - 160131
Application: RS12 - Dual G,Y,R Signals / 2-Way Signaling, or G,Y,R & Arrow(s)
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 20 of 27 Release Date - 160131
Application: RS12 - Quad G,Y,R Signals / 4-Way Signaling.
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 21 of 27 Release Date - 160131
Application: RS12 - School Zone / Caution Signaling
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 22 of 27 Release Date - 160131
Application: RS12 - RxR Signal *RxR Signal must be compatible or converted with 120VAC lighting
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 23 of 27 Release Date - 160131
Application: RS12 Single G,Y,R Signal w/ Crosswalk - Walk on Green
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 24 of 27 Release Date - 160131
Application: RS12 Single G,Y,R Signal w/ Crosswalk - Walk on Red
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 25 of 27 Release Date - 160131
Application: RS12 Dual PED / Crosswalk Signals, 2/4 Way Signaling.
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 26 of 27 Release Date - 160131
Application: RS12 Racing Tree
Caution!: If you need assistance, please consult a qualified electrician.
Warning!: SHOCK HAZARD! DO NOT HANDLE CONTROL WHILE POWERED ON.
TS CONTROLS Signal & Lighting Controls www.tscontrolsonline.com Email: [email protected]
RS10/RS12 Page 27 of 27 Release Date - 160131
WARRANTY / RETURN FORM
MODEL: ____ RS/TS 10 ____ RS/TS 12 TS14 OTHER PURCHASE DATE: ___________ (Please Specify Model)
1 YEAR - LIMITED WARRANTY
All TS series are warranted against manufacturing/workmanship defects for a period of 1 year from
date of purchase. Any TS series control that is used for other than the purpose intended, resulting in
damage, personal or property, is the rightful owners responsibility. This warranty does not cover, improper
installation /application, modification, misuse, abuse, power surge, brown outs, lightning strikes, and any
other “act of god” resulting in damage, whether personal or property. TS series controls are designed for
indoor and private use only. And, are not intended for industrial / commercial, or municipality use.
Return Policy:
TS Series controls returned for refund, or repair, without proof of purchase will not be honored under
warranty. TS series controls under warranty will be repaired/replaced, at the discretion of the
manufacturer, as necessary. Any TS series control returned for repair after warranty period, “out of
warranty” will be repaired at a flat rate cost of $20, and will be warranted for a period of 30 days.
Mail / Remit to: Brent Anderson
2725 Castleton Ave.
Toledo, OH 43613
Email: [email protected]
Directions: Complete the requested information below.
Name: __________________________________________________________
Address: ________________________________________________________
City-State-Zip: ___________________________________________________
Phone#: (_______)________________________________________________
E-mail (optional): ________________________________________________
(Please Check)
Reason for return / description of failure / problem. Repair / Exchange Refund (See Return Pol icy)
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________