    Mechanism, design and motion control of a linkagechewing device for food evaluation

    W.L. Xu a,*, D. Lewis a, J.E. Bronlund a, M.P. Morgenstern b

    a Institute of Technology and Engineering, College of Sciences, Massey University, New Zealandb New Zealand Institute for Crop and Food Research Ltd., New Zealand

    Received 30 January 2007; received in revised form 12 March 2007; accepted 16 March 2007Available online 27 April 2007

    Abstract

    A linkage-based chewing device is proposed to perform standardised chewing for use in food evaluation. The linkagefor chewing is firstly specified in terms of the trajectory of the first molar and the chewing force, according to the in vivomeasurements of the human chewing ranging from grinding (or lateral chewing) to crunching (or vertical chewing). A four-bar linkage is synthesized to achieve the lateral chewing trajectory of the molar, and by adjusting the ground link length toachieve any trajectory between the lateral and vertical chewing. A six-bar crank-slider linkage is then designed to guide themolar teeth moving in a set orientation while still following the chewing trajectory produced by the four-bar linkage. Thechewing device based on the six-bar linkage is constructed with inclusion of anatomically correct teeth for reducing the

    food particle size, a food retention device for collecting the food particles being chewed and a shock absorber for prevent-ing excessive chewing force. The linkage chewing device is evaluated by simulations of kinematics and dynamics and actualmeasurements of the trajectory and chewing force. For the motion control of the actuator, the chewing velocity along thetrajectory is also profiled for occlusal phase and opening/closing phase of the chewing, and the variations of the chewingfor different foods are set in a GUI (graphical user interface) in Labview. The device is finally validated by chewing on acereal bar and comparing the resulting particle size of the bolus with those by human subjects. 2007 Elsevier Ltd. All rights reserved.

    Keywords: Human chewing; Food evaluation; Chewing device; Adjustable linkage; Motion control

    1. Introduction

    The human masticatory system is a complex system that comprises of an upper and lower jaw that haveteeth located on them. It also includes a tongue, cheek and saliva production capability. When masticationis performed, the lower jaw (mandible) is moved by muscles that are attached between it and the upper jaw[1]. The chewing movement begins with the mandible opening thereby creating a space between the teethlocated on skull and the mandible. The tongue then places food particles that need chewing on to the molars

    0094-114X/$ - see front matter 2007 Elsevier Ltd. All rights reserved.

    doi:10.1016/j.mechmachtheory.2007.03.004

    * Corresponding author. Tel.: +64 9 414 0800; fax: +64 9 443 9774.E-mail address: [email protected] (W.L. Xu).

    Available online at www.sciencedirect.com

    Mechanism and Machine Theory 43 (2008) 376389

    www.elsevier.com/locate/mechmt

    MechanismandMachine Theory

    mailto:[email protected]:[email protected]
  • 7/31/2019 Tricko Original

    2/14

    on one side of the mouth. The mandible then closes and breaks up these food particles and then the particlesfall off the teeth back on to the tongue for repositioning during the next cycle [2]. The opening of the mouth ofthe chewing cycle is approximately vertical [3]. The speed of the mandible in the opening phase initially startsslowly and increases as the mouth opens. When the mouth starts to close, the mandible moves laterally out-ward and initially closes quickly coming back towards the teeth and then slows for occlusion.

    The trajectories of the teeth during chewing vary substantially for different foods in the frontal plane, but,they are very close to a straight line in the sagittal plane [4]. This line may vary from a vertical line where theteeth come together at a 0 angle and a line where the teeth come together at a 30 angle. The trajectories usedto chew different food particles differ depending on both the shape and the texture of the food particles, thusgenerating a different chewing action for different foods. If a vertical chewing motion is used, the teeth usetheir cusps to fracture the food particles. Where as if a more lateral chewing motion is used, the teeth use theirsharp edges to function as blades and cut up the food particles [5].

    As food properties affect the chewing trajectories, a considerable amount of work has been done to deter-mine chewing movements in food sciences [4,6,7]. Measurements were made continuously over the masticatoryprocess and included some of the following: frequency, length of chewing, tracking of jaw movement, forcedistribution, application of compression and shear forces on the food and particle size and structure of thebolus just prior to swallowing. These quantities vary between subjects (e.g. due to differences in jaw geometry,

    teeth shape, sensitivity to pain) and food texture (e.g. elasticity, hardness, adhesion especially to dentures,etc.).

    There are a variety of instruments or devices available for evaluating food properties. However, suchdevices usually use a simple straight motion (mostly food compression) and are not able to simulate the entiresuite of complex functions and movements involved during mastication. Since the early 1990s there have beenattempts in developing masticatory robots for food texture assessment [811]. While robotic chewing devicesthat possess multiple degrees of freedom (DOF) of motion are able to reproduce chewing behaviour in three-dimensional space, a single DOF linkage device for chewing is pursued in this study. A linkage device is muchsimpler in structure and motion control and more reliable in operation. The presence of a straight line trajec-tory in the sagittal plane presents the opportunity to reproduce the chewing motion in 2D using a simplelinkage.

    In this paper, the chewing linkage is specified to meet basic human chewing behaviours in terms of kine-matic requirements and forces. Mechanism design is carried out using an atlas for the generation of trajectory,and the design also takes into account the set teeth orientation. To produce a range of chewing trajectories, thelinkage is made with an adjustable ground link. The motion of the actuator is planned according to differentvelocity requirement in occlusal phase and opening/closing phase of the chewing, and the GUI (graphical userinterface) in Labview facilitates the various chewing operations of the device. The validation of the device isperformed by chewing on a real food.

    2. Design specifications of a linkage chewing device

    Each mandibular tooth has its own trajectory while chewing, and a typical trajectory can be defined by ver-tical and lateral displacements and opening (exit) and closing (entry) angles, as illustrated in Fig. 1, as well asthe time to complete them [2]. The trajectory of the first molar is simply a vertically compressed version of theincisor trajectories, while the entry and exit angles to and from occlusion are not greatly different [12]. Theincisor trajectory can be measured but vary between lateral chewing (grinding) and vertical chewing (crunch-ing), depending on the type of food being chewed. Due to the fact that chewing is performed on the molarteeth, the chewing device must follow the trajectories of the molar teeth. As no actual data is available, thetrajectories of the molar teeth during chewing can be estimated by simulation from the trajectories of the inci-sor [12,13], as given in Table 1.

    To evaluate different foods the chewing device to be developed should be able to achieve any trajectorybetween lateral and vertical trajectories. The device should also meet cycle time and occlusal time. Therefore,the linkage for chewing can be specified by the set of parameters in Table 1. Furthermore, the forces appliedon the teeth vary with the type of food being chewed. The force applied to a single tooth is also different to that

    of total force between all the contacting teeth during chewing. On foods such as biscuits, carrots and cooked

    W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389 377

  • 7/31/2019 Tricko Original

    3/14

    meats forces range between 70 and 150 N on a single tooth [14]. Thus, the chewing force that the linkage canapply on food samples is specified as 150 N at maximum.

    3. Basic linkage mechanism for the chewing device

    A four-bar linkage (Fig. 2) is a relatively simple mechanical mechanism and a point P on the coupler cantrace a 2D trajectory. The kinematic parameters for the linkage include crank link a, coupler link b, followerlink c and ground link d, as well as angle of c and distance BP for the coupler point P. A four-bar

    Fig. 1. A tooth trajectory and its defining parameters.

    Table 1

    Values of the trajectory parameters for lateral and vertical chewing [12,13]Lateral chewing Vertical chewing

    Closing angle () 46.6 72.5Opening angle () 113.1 78Total angle () 66.5 5.5Vertical opening (mm) 14.6 15.1Lateral displacement in opening (mm) 1.1 0.4Lateral displacement in closing (mm) 4.0 3.1Cycle time (s) 0.77 0.7Occlusal time (s) 0.12 0.16Opening/closing time (s) 0.65 0.54

    Fig. 2. Kinematic parameters for a four-bar linkage [15].

    378 W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389

  • 7/31/2019 Tricko Original

    4/14

    linkage in its standard form can only perform one set trajectory, and in the case where a range of trajectoriesare required to be reproduced, the ground link can be made adjustable manually.

    The Cedarville engineering atlas [15] was used to find a number of suitable trajectories that have entry andexit angles that closely match a lateral chewing cycle as specified in the above section. When a trajectory wasfound that matches the desired occlusal angles of a lateral chewing motion it was marked down as a possible

    solution. As vertical chewing motions are also required, this can be achieved by further changing the groundlink length. Fig. 3 shows the final choice of the lateral chewing trajectory where the link parameters are shownat the top with varying BP length.

    After the occlusal angles were examined, the final design chosen was Crank (link a) = 1, Follower (linkc) = 3, Ground (link d) = 3.85 to achieve horizontal and vertical chewing motions, Coupler (linkb) = 3.5, Coupler (distance BP) = 3, Coupler (angle c) = 60. These values are only ratios of the linklengths, relative to the Crank (a), and the actual links can be of any length as long as the ratios are obeyed.To make the actual linkage chewing device to be as compact as possible, a smallest feasible physical crankchosen is 10 mm long when its pivotal and joint bearings are taken into account.

    The chewing trajectories by the linkages were compared with those from real measurements of humanchewing in Table 2. It can be found that in terms of the occlusal angles, the linkage can achieve a close matchwith the lateral chewing trajectory while still having reasonable trajectories for the vertical chewing; however,

    the linkage has larger vertical opening and lateral displacements. This should be acceptable as these aspects of

    Fig. 3. Candidate trajectories of the four-bar linkage.

    Table 2Comparison between the trajectories by linkages and humans

    Lateral chewing Vertical chewing

    Human Linkage Human Linkage

    Closing angle () 46.6 45 72.5 99Opening angle () 113.1 112 78 105Total angle () 66.5 67 5.5 6Vertical opening (mm) 14.6 23 15.1 34Lateral displacement in opening (mm) 1.1 3 0.4 3

    Lateral displacement in closing (mm) 4.0 9 3.1 0

    W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389 379

  • 7/31/2019 Tricko Original

    5/14

    the chewing trajectory do not impact on the food breakdown process as long as they are sufficient to clear thefood between chewing cycles. The motor can be sped up during this part of the cycle to ensure representativemasticatory behaviour is simulated.

    Fig. 4. Three chewing trajectories by adjustable four-bar linkage.

    Fig. 5. Construction of the adjustable four-bar linkage: (a) adjustable ground link; (b) adjustable four-bar linkage; (c) major parts chosen.

    380 W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389

  • 7/31/2019 Tricko Original

    6/14

    Fig. 4 depicts three trajectories by the linkage at the ground length of 38 mm, 44 mm and 50 mm, respec-tively. It can be seen that the occlusal position shifts, the vertical opening displacement increases and the lat-eral displacement decreases as the length of the ground link gets smaller. This confirms that the linkage is ableto reproduce various chewing trajectories. The chewing device to be constructed can adjust the occlusal posi-tion of the teeth by varying the distance between upper and lower teeth.

    Once the link lengths of the four-bar linkage were determined, the design of the mechanical device couldcommence. The basic designs of the crank, coupler and follower are straightforward only with the joint pointsof the links matching the lengths determined. The ground link needs to have a 12 mm adjustment that effec-tively changes the link length between 38 mm and 50 mm. Fig. 5 shows the final four-bar linkage constructedwhere the adjustable ground link was achieved using a threaded rod to move a block when the rod is turned.

    4. Six-bar linkage mechanism for the chewing device

    4.1. The six-bar linkage

    As discussed before, the adjustable four-bar linkage can produce the required trajectories. However, it can-not keep the mandible or teeth in same proper orientation over the entire trajectory. A simple way to resolve

    this is to add another two links (links 5 and 6 in Fig. 6) to the four-bar linkage, thus making it a six-bar link-age. The two links are connected by a sliding joint between them, and link 5 is attached onto the coupler by arevolute joint and link 6 onto the ground by another sliding joint. The set of teeth is mounted atop link 5,which is forced to move in a plane constrained by the two sliding joints. To produce the chewing trajectoriesin the sagittal plane of an angle ranging between 0 and 30 to the horizontal plane, the base of the six-barlinkage can be tilted manually.

    To have balanced dynamics to reduce the forces and impact, the chewing device was constructed symmet-rically by placing two identical four-bar linkages on each side of the device ( Fig. 6). The cranks of the twolinkages were mounted on a single shaft driven by a single motor via a spur-gear train.

    4-bar linkages

    Link 5

    Link 6

    Sliding joint

    Revolute joint

    Frame tilted for a

    saggital plane

    Mandible teeth

    attaching point

    Fig. 6. Design of a six-bar crank-slider linkage.

    W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389 381

  • 7/31/2019 Tricko Original

    7/14

    While being constructed, the six-bar linkage was extended to include anatomical teeth with a quick attach-ment mechanism, a molar teeth repositioning table, a shock absorber that prevents excessive impact force anda simple food retention mechanism that collects chewed food particles. Food repositioning may be performedby the operator between chewing cycles. Fig. 7 shows a photograph of the built chewing device where the link-age is inverted with mandible teeth up and the maxilla teeth down for convenience of collecting chewed food

    particles.

    4.2. Motion planning

    While the linkage can trace a desired chewing trajectory, the velocity along the trajectory still needs to beprofiled. With respect to a chewing trajectory (Fig. 8), the molar teeth moves at constant velocity during theocclusion phase, and then speeds up from occlusal velocity to a maximum velocity and back down to occlusalvelocity in a specified time.

    The occlusion starting and ending positions can be found by a horizontal line of 0.5 mm down from themaximum intercuspal position [13]. The linkage constructed was simulated for a lateral chewing trajectoryin SolidWorks (Fig. 8). Each point on the trajectory corresponds to the crank shaft rotating 4.5 and theocclusal phase of 36 turn of crank shaft is found. As the time to complete this phase is specified as 0.12 s

    (Table 1), the occlusal velocity of the crank is 300/s.The start angle and final angle of crank are found 18 and 342 (Fig. 8a). Considering a 1:42 gear reduction

    between the motor and the crank, the occlusal velocity, start angle and final angle of the motor shaft are

    Food retention

    mechanism

    Mandible molar

    Maxilla molar

    Link 5

    Link 6

    Coupler

    Follower

    Ground link

    Crank

    Motor & control

    unit

    Handle for the

    adjustable groundQuick teeth

    attachment

    mechanism

    Handle for the

    adjustable sagittal

    plane

    Shock absorber

    Handle for the

    adjustable maxilla

    Maxilla molar

    repositioning

    table

    Fig. 7. The constructed chewing device.

    382 W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389

  • 7/31/2019 Tricko Original

    8/14

    12,600/s, 756 and 14,364, respectively. The time taken to open and close the mouth is specified of 0.65 s(Table 1). Based on these values, a cubic trajectory of the motor shaft is found as [16]

    ht 756 12; 600t 38; 471t2 39; 457t3 1

    _ht 12; 600 76; 942t 118; 371t2 2

    ht 76; 942 236; 742t 3

    The above planned trajectory is for the lateral chewing. As the chewing device is intended for performing avariety of trajectories between the lateral and vertical chewing, the trajectory other than the lateral chewingwill be different. An actual planned trajectory is decided by occlusal angle, occlusal time and opening/closingtime (Fig. 8b), which can be set up in the motion control GUI (see Section 6).

    4.3. Motor selection

    After the materials of the parts are specified for the linkage and a constant force of 150 N is applied ver-tically at the coupler point P, the linkage can be simulated in SolidWorks to find the driving torque required

    Fig. 8. Definition of the occlusal phase.

    0.00 0.06 0.12 0.18 0.24 0.30 0.36 0.42 0.48 0.54 0.60

    Time (sec)

    -1498

    -473

    552

    1578

    2603

    Moment-Y

    (newton-mm)

    Fig. 9. The torque required at the crank shaft.

    W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389 383

  • 7/31/2019 Tricko Original

    9/14

    at crank shaft. Fig. 9 shows a crank torque versus time plot when the crank runs at 300 /s which is the occlusalspeed of the crank. The maximum torque the crank requires to run the chewing device is 2.6 N m. Conse-quently, the output of the geared motor must be able to produce a minimum torque of 2.6 N m at 300/s(or 78 rpm) to achieve the desired chewing force of 150 N. In addition, the required acceleration is estimatedat 190/s2 [12].

    A brushless DC motor finally chosen could deliver 6.0 N m of torque continuously and 7.5 N m of torquefor short periods. With the gear ratio of 1.57, the torque, speed and acceleration at the crank can be 3.82 N m,190 rpm and 414/s2, respectively, which meets the required performance of the crank (Table 3).

    5. Analysis of the linkage chewing device

    5.1. Trajectory and force evaluation

    A simple way to compare the trajectories that the device can produce and the desired chewing trajectories isto use a pen to trace the trajectories achieved and overlay them. The pen used to trace the trajectories wasmodified so that the spring was used to push the nib out rather than retracting it. The pen was securelyattached to the slider of the six-bar linkage and the card was setup in a vertical fashion so that the nib was

    Table 3Comparison of required and achievable specifications at the crank

    Parameter Required Estimated capability

    Speed (rpm) 100 190Torque (N m) 2.6 3.82Acceleration (/s2) 190 414

    Fig. 10. The overlay of the achieved and desired trajectories (solid line = actual, dotted line = desired): (a) later chewing; (b) vertical

    chewing.

    384 W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389

  • 7/31/2019 Tricko Original

    10/14

    in contact with the card. It was found from numerous measurements that the trajectories produced by thechewing device are close to the desired ones during the occlusion but slightly different in the opening/closingphases, as illustrated in Fig. 10. This minor difference is due to the play in the joints of the linkage, and insig-nificant to the entire chewing as it occurs only in the opening/closing free motion.

    The force testing was performed by the use of a load cell. This idea involves having the teeth attaching point

    (link 5) pressing down on the load cell to measure the force applied. The chewing device was set to run con-tinuously and the force that the linkage can apply was measured. The results show that the chewing devicecould comfortably apply the desired 150 N chewing force and would stall at approximately 260 N.

    5.2. Stress and deformation analysis

    The six-bar linkage can be simulated in COSMOS/Works to test if the device can withstand the forces thatwill be applied. When a force of 150 N was applied at the teeth attaching point, the stress analysis was per-formed at the occlusal position. Results show that there is no excessively large stress on the device, withthe largest stress being concentrated where the linear bush of the link 5 of the four-bar linkage is ( Fig. 11).This is due to the fact that the linear bush makes a relatively sharp edge in the structure. This stress concen-tration was expected when the structure was designed, and hence needs not to be avoided as the link 5 is strong

    enough to withstand that level of stress.The deformation of the device was also analysed to examine the buckling that occurs when the 150 N load

    was applied at the teeth attaching point. The results show that the deformation is 0.004 mm at the place wherethe linear bush meets the shaft that it slides on (Fig. 12). This can be considered negligible as this amount ofbuckling in the shaft will not cause the linear bush to jam.

    Fig. 11. The stress analysis of the linkage.

    W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389 385

  • 7/31/2019 Tricko Original

    11/14

    6. Control system and software

    Because the chewing cycle time and occlusal time vary between people and foods being chewed, motioncontrol of the motor is required. This control was implemented in National Instruments Labview program-ming language to allow flexibility in subsequent prototypes. As the device was to be controlled from a Labviewprogram it made sense to choose a control card that could easily be interfaced with Labview. The communi-cation between the control card and the computer based software was done via a RS-232 serial interface.

    For the chewing device to function in a way that the human operation would be satisfied with, it is impor-tant to include all the functions that would be necessary for simple operation. These functions are as follows,which can be seen in GUI in Fig. 13:

    Set to lower position this function sets the chewing device to the occlusal position so that the teeth can bealigned when setting up the device.

    Set to top position this function sets the chewing device to the position where the teeth are maximum dis-tance apart so that a food sample can be placed in it. This can be thought of as the mouth being open.

    Start chewing this will be used to make the device chew by making the device follow a velocity profile thatmatches that of a human chewing velocity profile. The number of chews will also be able to be set.

    Single cycle this function will be used as a quick select one chew button and will only perform one chew-ing cycle.

    Low speed manual control the user will be able to use this control to make the chewing device move at aslow speed to check the occlusion once the teeth have first been set up.

    Master stop this will be used as a safety feature that allows the user to stop it at any time during any func-tion. It should be cautious that this stop stops only the execution of those motion programs by setting the

    velocity of the motor to zero. To enhance the safety, an emergency button is still in order.

    Fig. 12. Deformation analysis of the linkage.

    386 W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389

  • 7/31/2019 Tricko Original

    12/14

    The operator may wish the chewing device to chew foods differently. To this end, the device has to allow

    different velocity profiles (Fig. 14). This can be implemented by changing the parameters for the velocity pro-files in the controller. These control parameters are:

    Occlusal time the time the occlusal phase is to take. Opening/closing time the time it takes to return to the start of the occlusal phase. Occlusal angle this specifies the point where the occlusion begins and ends.

    7. A chewing experiment

    The chewing device designed is to reproduce the trajectory of the molar teeth during human chewing cycles.It employs anatomically correct teeth geometries with accurate occlusion. The trajectory of the jaw can beadjusted to give a range of vertical and lateral movements so that different foods can be processed appropri-

    ately. The speed of the jaw can also be adjusted to simulate the motions observed during human chewing.

    Fig. 13. GUI implementing the operational functions.

    Fig. 14. GUI for specifying the occlusion.

    W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389 387

  • 7/31/2019 Tricko Original

    13/14

    Validation of the device was performed by comparing the resulting particle size of the bolus produced bythe chewing device with the particle size of a bolus produced by a human subject. The device was tested on acereal bar by taking 1 g slices and placing them onto the teeth. The machine was made to undergo two cyclesafter which artificial saliva was added in the proportion measured during human chewing trials. The food par-ticles were rearranged on the teeth and the device was made to carry out another 5 cycles. The particles wereagain rearranged on the teeth before chewing for another 5 cycles, repeating this pattern until the total number

    of chewing cycles was that observed in human chewing. The bolus was then collected and washed through1.4 mm and 0.25 mm sieves and dried.

    The fraction of solid particles passing through the 1.4 mm sieve was then compared with the results col-lected from human subjects as a partial validation of the device. The results are seen in Fig. 15, where thosein the shaded box is the particle size using the chewing device developed and the rest is that of human chewingon 2 g and 4 g food sample.

    It can be found that although there is some variability between the fractions passing through the 1.4 mmsieve in the device chewed samples, it is of a similar magnitude to that observed in the human subjects. Whilefurther validation is necessary it is believed that the device has enough flexibility to be developed into a routinelaboratory apparatus for the purposes of pre-processing foods in a systematic and reproducible mannerfor subsequent nutritional analysis and for evaluation of the dynamics of food texture changes duringchewing.

    8. Conclusion

    The linkage chewing device for use in food evaluation was developed and the mechanism design, construc-tion, motion control and simulation and experimental validation were described. The design specificationswere derived from published in vivo measurements of human chewing. While the four-bar linkage was forchewing trajectory, the six-bar linkage was to keep the molar teeth moving in a set orientation. A varietyof chewing trajectories were achieved by varying the ground link length. The motion of the actuator wasplanned to implement various chewing motions required for different foods. The operation of the devicewas made easy via GUIs programmed in Labview. While initial experiments show the promising results bythe device, more validations of chewing are required before it becomes a routine laboratory apparatus for

    the purposes of pre-processing foods.

    0%

    10%

    20%

    30%

    40%

    50%

    60%

    70%

    80%

    90%

    100%

    0 2 4 6 8 10 12 14

    Subject number

    Fractionpassingthrough1.4m

    ms

    eive

    2g sample

    4g sample

    Chewing device

    Chewing

    device

    Fig. 15. Comparison of particle size between human subjects and the chewing device.

    388 W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389

  • 7/31/2019 Tricko Original

    14/14

    Acknowledgements

    The work in this paper was supported by the Baking Industry Research Trust, New Zealand and by the NZFoundation for Research, Science and Technology, through Innovative Foods contract C02X0401 (LifestyleFoods for Energy Balance The Carbohydrate Story). It is acknowledged that the validation data were pro-

    vided by Kylie Forster and Christine Lawrence of Institute of Food, Nutrition and Human Health, MasseyUniversity, New Zealand.

    References

    [1] P.W. Lucas, The structure of the mammalian mouth, in: Dental Functional Morphology: How Teeth Work, Cambridge UniversityPress, United Kingdom, 2004, pp. 1354.

    [2] P.W. Lucas, How the mouth operates, in: Dental Functional Morphology: How Teeth Work, Cambridge University Press, UnitedKingdom, 2004, pp. 5586.

    [3] F. Mongini, G. Tempia-Valenti, G. Benvegnu, Computer-based assessment of habitual mastication, Journal of Prosthetic Dentistry55 (1986) 638649.

    [4] K. Anderson, G.S. Throckmorton, P.H. Buschang, H. Hayasaki, The effects of bolus hardness on the masticatory kinematics, Journalof Oral Rehabilitation 29 (2002) 689696.

    [5] P.W. Lucas, Tooth shape, in: Dental Functional Morphology: How Teeth Work, Cambridge University Press, United Kingdom,2004, pp. 87132.[6] M.A. Peyron, C. Lassauzay, A. Woda, Effects of increased hardness on jaw movement and muscle activity during chewing of visco-

    elastic model foods, Experimental Brain Research 142 (2002) 4151.[7] K. Foster, A. Woda, M.-A. Peyron, Effect of texture of plastic and elastic model foods on the parameters of mastication, Journal of

    Neurophysiology 95 (2006) 34693479.[8] H. Takanobu, T. Yajima, et al., Quantification of masticatory efficiency with a mastication robot, in: Proceedings of the IEEE

    Internal Conference on Robotics and Automation 1998, pp. 16351640.[9] W.L. Xu, J. Bronlund, J. Kieser, A robotic model of human masticatory system for reproducing chewing behaviours, IEEE Robotics

    and Automation Magazine 12 (2) (2005) 9098.[10] J. Torrance, J.-S. Pap, W.L. Xu, J. Bronlund, K.D. Foster, Motion control of a chewing robot of 6 RSS parallel mechanism, in:

    Proceedings of International Conference on Autonomous Robotics and Agents, Palmerston North, New Zealand, 1214 December2006, pp. 593598.

    [11] J.-S. Pap, W.L. Xu, J. Bronlund, Design of a biologically inspired chewing robot, IEEE Transactions on Industrial Electronics, in

    press.[12] D. Lewis, A robotic chewing device for food evaluation, Master of Engineering Thesis, Massey University, New Zealand, 2006.[13] T. Ogawa, M. Ogawa, K. Koyano, Different responses of masticatory movements after alteration of occlusal guidance related to

    individual movement pattern, Journal of Oral Rehabilitation 28 (2001) 830841.[14] D.J. Anderson, Measurement of stress in mastication, Journal of Dental Research 41 (1956) 175189.[15] T. Thompson, How to use and interpret the coupler curve and centrode atlas, 1999. Available from: .[16] J.J. Craig, Introduction to Robotics, Mechanics and Control, third ed., Prentice Hall, 2004.

    W.L. Xu et al. / Mechanism and Machine Theory 43 (2008) 376389 389

    http://www.cedarville.edu/academics/engineering/kinematics/ccapdf/howto.htmhttp://www.cedarville.edu/academics/engineering/kinematics/ccapdf/howto.htmhttp://www.cedarville.edu/academics/engineering/kinematics/ccapdf/howto.htmhttp://www.cedarville.edu/academics/engineering/kinematics/ccapdf/howto.htm