Page 1: Transformer Oil Regeneration Technology

Copyright 2017 | STACO

REOIL

Transformer Oil Regeneration

Engr. Rahul [email protected]

+966 551888755 Skype: rahul_staco

Page 2: Transformer Oil Regeneration Technology

About Ekofluid

Copyright 2017 | STACO

• First unit built in 1996

• Based in Austria , Europe

• Production and Services

• We know everything about transformer oil

• 20 years of experience

• > 5 mil. tons of oil regenerated

• > 250 transformers

• > 30 transformers with corrosive sulfur

• Clients using our equipment ABB, Siemens

Page 3: Transformer Oil Regeneration Technology

REOIL Technology

Copyright 2017 | STACO

• Corrosive Sulfur removal

• Complete Oil regeneration like new oil

• Highly effective moisture removal

• Decrease in total sulfur content

• Highly efficient elimination of DBDS

• Mobile unit, Works on site

• Works on a live transformer

Page 4: Transformer Oil Regeneration Technology

Filtration vs Regeneration

Copyright 2017 | STACO

• Filtration removes primary contamination of transformer oil – i.e. moisture and gases.

• Regeneration removes completely corrosive sulfur and aging byproducts – (micro particles of paper , wood and copper reaction)

• Improves :- – Tan delta– Viscosity– Acidity – ( Neutralization)

• Regeneration also improves the color of the contaminated Oil

Page 5: Transformer Oil Regeneration Technology

Risk Factor

Copyright 2017 | STACO

• Corrosive oil

• High working temperatures

• Insufficient maintenance

• Overloading of transformer

• Insufficient cooling

Page 6: Transformer Oil Regeneration Technology

Which transformers are at risk?

Copyright 2017 | STACO

• Primarily transformers built between 1999 – 2007

• Transformers after maintenance

• Transformers after oil exchange

• Transformers after top up of oil

• Transformer already passivated

Page 7: Transformer Oil Regeneration Technology

REOIL Plant

Copyright 2017 | STACO

• Ability to economically regenerate used transformer oil

• Removes acidity , sludge and other ageing byproducts

• Ability to regenerate adsorption media such as fuller earth

• Entire process consists of two phases

Regeneration phase

Oil is heated then pumped through columns where activated media attracts ageing by products. Oil is then filtered and directed into the vacuum chamber for degassing

Reabsorption phase

Starts when activated media is fully saturated by controlling temperature, time, vacuum etc. Activated media is restored into original state. Process can be repeated more than 400 times before replacement

Page 8: Transformer Oil Regeneration Technology

Performance

Copyright 2017 | STACO

• Single column can process +-550 liters of aged oil

• Real life results exceed IEC 60422 values

Property (Unit) IEC 60422 Value REOIL Guaranteed Value

Dielectric Strength (kV/2.5mm) ≥50 ≥75

Dielectric Dissipation factor at 90 <0.01 <0.005

Neutralization number (mg KOH/g) <0.03 <0.01

Water Content (ppm) <10 <10

Interfacial Tension (mN/m) >35 >45

Page 9: Transformer Oil Regeneration Technology

User Interface

Copyright 2017 | STACO

Page 10: Transformer Oil Regeneration Technology

Operations

Copyright 2017 | STACO

• 2 operators required for setup

• No more than 2 hours of labor a day

• Operator is only supervising

• Access to the system controlled by password

• System is fully automatic

Page 11: Transformer Oil Regeneration Technology

Control

Copyright 2017 | STACO

• All units are fully automatic

• Controlled by PLC Siemens SimaticS7

• Visualized by SCADA Promotic8

• All software runs on Windows 7

• SCADA installed on a notebook

• Local Wi-Fi service

• eWon3G remote access service

Page 12: Transformer Oil Regeneration Technology

Compatibility & Reliability

Copyright 2017 | STACO

Reliability:

• All critical components are manufactured in-house

• All components are certified and conform to EU standards

• Components from reputed and worldwide suppliers

• All components are tested in-house before put into production

Compatibility:

• Comes in different modules/combinations

• Regeneration process remains the same

• Reabsorption process remains the same

• Works in conjunction with existing equipment

Page 13: Transformer Oil Regeneration Technology

Safety

Copyright 2017 | STACO

• Automatic operation with alarms

• Automatic shutdown procedures

• Pressure release valves

• Aeration valves

• Protection pots in front of pumps

• Automatic inlet and outlet valve

• Vacuum safety hoses

• Transformer oil level monitoring

Page 14: Transformer Oil Regeneration Technology

Training

Copyright 2017 | STACO

• Comprehensive training program

• Training offered at customer’s workshop

• Training offered in our own workshop

• All training is done hands on with extensive documentation

Page 15: Transformer Oil Regeneration Technology

Support

Copyright 2017 | STACO

• Dedicated support with every unit

• Possibility of remote debugging on site

• Telephone and email support

• All critical components are kept on stock

• 24 months guarantee on all components

• All software back up in the cloud and available for immediate download

• Lifetime guarantee on Reabsorption process

• Remote access for emergency repairs facility directly from the factory and look after the machine performance by specialist who will also provide monthly reports of machine performance

Page 16: Transformer Oil Regeneration Technology

REOIL plant type 5 model no. 51211

Copyright 2017 | STACO

Page 17: Transformer Oil Regeneration Technology

REOIL Plant Type 5

Copyright 2017 | STACO

Page 18: Transformer Oil Regeneration Technology

Q & A

Copyright 2017 | STACO

Engr. Rahul [email protected]

+966 551888755Skype: rahul_staco

Questions