towards leadership through commitment - · pdf filetitle iec is : 325 is : 4722 is : 12824 is...
TRANSCRIPT
through commitmentTowards leadership
Reliable Range of AC Induction Motors
ISO 9001 - 2008
Motors, Encoder Motors and other special motors asper the customer’s specifications.
General Engineering,Material Handling Process Plants & Refineries
Power SectorMachine Tools & Machinery
Paper, Textile, PackagingSteel Plants & Forging
Ranchi
Rourkela
LHP - Motors & Drives. In every corner of India
and in almost every industry.
Lhp
/ MK
TG
/WI7
205/
RE
V-8
/01-
05-1
2National Sales & Marketing Office
Corporate office & manufacturing plant National Sales & Marketing office
B-11, M.I.D.C. Chincholi, Solapur- 413255 INDIATel.: +91-217-2357001 Fax : 2357006,Email : [email protected]
Laxmi Hydraulics Pvt. Ltd. Laxmi Hydraulics Pvt. Ltd.A 502, G.O. Square, Wakad, Jagtap Dairy Road,Pune - 411057 Maharashtra - INDIATel.: +91 9921488299 (Board)www.lhp.co.in
Faridabad
Quick Selection Guide to
Squirrel Cage
AC Induction MotorsRating up toPoleMounting
:::
315 kW (425 HP)2 / 4 / 6 / 8B3 / B5 / B6 / B7 / B8B14 /B 35 /B 34 / V1 / V3 / V5 / V6 / V15 / V18 / V19 / V36
You are about to select
India's one of the most
reliable Induction Motors
which assures you
trouble-free
performance.
Selecting a LHP motor
will keep your equipments
running round the clock,
year after year, ensuring
customer satisfaction.
This selection guide will
help you to find the
right motor for your
application. In case you
don't find one, do get in touch
with us.
We would be glad to
develop a Special Purpose
Motor specifically for you.
Q Wide range
Highly reliableQ
Greetings to all.
With a glowing
heritage of 30 years,
LHP is an established
and recognised brand
of Motors & Drives
in India.
LHP provides a wide
range of products
and undertakes special
developmental
challenges of varied
customer requirements.
Today LHP is an acclaimed
of leading
companies in India.
With this background,
we are making news
into international
markets and receiving
wider acceptance
from companies
across the world.
LHP's right attitude of
the highest quality in all
aspects is the assurance
of its becoming
a successful global brand.
'First Choice'
Sharadkrishna Thakre
Managing Director
Contents
Range of Products
Applicable Standards
Standard Motors : Output Summary
Mechanical Features
Dimensions of Foot Maunted Motors (B-3 Mounting) as per IS : 1231
Dimensions of Face Mounted Motors (B-14 Mounting) as per IS: 2223
Dimensions of Flange Mounted Motors (B-5 Mounting) as per IS: 2223
Permissible radial load for Standard Motors
Electrical Features
Guidelines for Motors Protection fuse rating
Electrical Performance Figures
Brake Motors
Crane Duty Motor
Electrical performance Figures of standard TEFC Foot, flange & Face Mounted &
Single phase motors.
Energy Efficient Motors (IE-2)
Cooling Tower Motors
Flame-proof Motors (Ex 'd' )
Roller Table Motors
Non-Sparking Motors (Ex 'nA')
Tolerance on Performance Values & Dimensions
Shipping Specifications
Information required along with Purchase Order / Enquiry
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
1
2
3
4-5
6
7
8
9
10
11
12-15
16-17
18-19
20-22
23-25
26
27-35
36
37-38
39-40
41
42
2.0 Range of Products
Table No. -1
Sr. No. Motor Frame Size
Standard motors
A. Single Phase
B. Three hase
Brake motors
Crane & Hoist Duty Motors
Flame-Proof Motors ( I, II A, II B
Flame roof motors (Gas group II )
Flame roof Brake Motors
Non-Sparking motors
Energy Efficient motor
Roller Table motors
P
Gas group )
-P C
-P
Flame-Proof Motors with CE ATEX
(IE-2)
63 to 90 (2 Pole)
63 to 100L (2 Pole)
80 to 100L (4 Pole)
71 to 100L (4 Pole)
63 to 355L
63 to 200L
63 to 160L
63 to 315L
63 to 315 L
71 to 180 L
63 to 80
63 to 355L
71 to 355L
112 to 355L
01
02
03
04
05
06
07
08 Special Motors
A. Electrical
01 Dual speed motor02 Dual voltage motor
(1:2 OR 1:1.7321ratio)03 15 to 60 Hz. frequency motor04 Other than standard 415V & 50 Hz
frequency rated motor05 High torque motor06 H class motor07 High slip motors08 Special Performance Requirements.09 Inverter duty motors10 Cooling tower motors
B. Mechanical
01 Non-standard mounting dimensions
02 Special shaft extension
03 Double extension
04 Low vibration and noise motors
05 Non-standard paint shade
06 Special shaft material
07 Motors for cooling towers
08 Geared motor
1
Type
CSR
CSIR
CSCR
3.0 Applicable Standards
The motors manufactured conform to the following National standards and equivalent International standards.
National
StandardsTitle IEC
IS : 325
IS : 4722
IS : 12824
IS : 4889
IS : 4691
IS : 6362
IS : 2253
IS : 4728
IS : 12065
IS : 12075
IS : 1231
IS : 2223
IS : 8223
IS : 1271
IS : 2148
IS/IEC :
IS : 12615
/IS/IEC-60029-1
60079-15
Three phase induction motors
Rotating electrical machines
Types of duty & classes of rating assigned to rotating electrical machines
Methods of determination of efficiency of rotating electrical machines
Degree of protection provided by enclosure for rotating electrical machinery
Designation of methods of cooling of rotating electrical machines
Designation for types of construction & mounting arrangements of
rotating electrical machines.
Terminal marking & direction of rotation for rotating electrical machinery
Permissible limits of noise levels for rotating electrical machines
Mechanical vibration of rotating electrical machines with shaft height 56 mm
& higher measurement, evaluation & limits of vibration severity.
Dimensions of three phase foot mounted induction motors
Dimensions of flange mounted induction motors
Dimensions and output series for rotating electrical machines
Thermal evaluation and classification of electrical insulation
Electrical Apparatus for Explosive Gas Atmospheres-Flame-proof enclosures 'd'
Three phase Induction motors with type of protection
Specification for Energy Efficient Induction Motors
IEC 60034-1
-
IEC 60034-2
IEC 60034-5
IEC 60034-6
IEC 60034-7
IEC 60034-8
IEC 60034-9
IEC 60034-14
IEC 60072-1
IEC 60072-2
IEC 60034
IEC 60079-1
IEC 6007 -15
--------
---------
IEC 60072-1
-11
9
IEC 60034-30
2
(Ex 'nA')
4.0 Standard Motors : Output Summary
Table No. - 2AFrame output summary for LHP Three Phase Induction Motor
Output(kw / HP)
Standard, Brake & Non-sparkingInduction Motor
Crane DutyMotor
Flame Proof Motor
Pole-wise Frame Size
2 Pole 4 Pole 6 Pole 8 Pole 4 Pole 6 Pole 2 Pole 4 Pole 6 Pole 8 Pole
0.12/0.16
0.18/0.25
0.25/0.33
0.37/0.50
0.55/0.75
0.75/1.00
1.10/1.50
1.50/2.00
2.20/3.00
3.70/5.00
5.50/7.50
7.50/10.00
9.30/12.50
11.00/15.00
15.00/20.00
18.50/25.00
22.00/30.00
30.00/40.00
37.00/50.00
45.00/60.00
55.00/75.00
75.00/100.00
90.00/120.00
110.00/150.00
125.00/170.00
132.00/180.00
160.00/215.00
180.00/250.00
200.00/270.00
225.00/300.00
250.00/335.00
315.00/425.00
63
63
63
71
71
80
80
90S
90L
100L
132S (112M)
132S
(132M)
160M
160M
160L
180M
200L
200L
225M
250M
280S
280M
315S
315M
(315M)
(315L)
(315L)
(315L)
(355L)
(355L)
(355L)
63
63
71
71
80
80
90S
90L
100L
112M
132S
132M
(160M)
160M
160L
180M
180L
200L
225S
225M
250M
280S
280M
315S
315M
(315M)
(315L)
(3 5L)
(3 5L)
(355L)
(355L)
1
1
(355L)
71
71
71
80
80
90S
90L
100L
112M
132S
132M
160M
(160L)
160L
180L
200L
200L
225M
250M
280S
280M
315S
315M
315
(355 )
(355L)
(355L)
--
L
315L
(355L)
(355L)
(355L)
L
63
63
63
71
71
80
90S
90S
90L
100L
132S
132S
(132M)
160M
160M
160L
180M
200L
200L
225M
250M
280M
280M
315S
315M
(315M)
(315L)
(315L)
(315L)
--
--
--
63
63
(315L)
71
71
80
80
90S
90L
100L
112M
132S
132M
(160M)
160M
160L
180M
180L
200L
225S
225M
250M
280S
280M
315S
315M
(315M)
(315L)
(315L)
--
--
--
71
71
71
80
80
90S
90L
100L
112M
132S
132M
160M
(160L)
160L
180L
200L
200L
225M
250M
280S
280M
315S
315M
315M
--
(315L)
(315L)
--
--
--
--
--
--
80
80
90S
90L
100L
100L
112M
132S
160M
160M
160L
180L
180L
200L
225S
225M
250M
280S
280M
315S
315S
315M
315M
--
(315L)
(315L)
--
--
--
--
--
--
80
80
90S
90L
100L
100L
112M
132S(112M)
160M (132M)
160M
160L
180L
180L
200L
225S
225M
250M
280S
280M
315S
315S
315
315
355
(355L)
(355L)
(355L)
--
--
--
L
L
L
(355L)
--
--
--
71
71
80
80
90S
90L
100L
112M
132M
(132M)
160M
160M
--
--
--
--
--
--
--
--
--
--
--
--
--
160L
--
--
--
71
80
80
90S
90L
100L
112M
132S
132M
(160M)
160M
160L
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Table No. - 2B
Frame output summary for LHP Single Phase Induction Motor
Note : Frame-wise ratings are as per IS standards except those ratings in bracket. These are as per LHP standard.
For Metric Frame Motors
4-Pole Frame 2-Pole Frame 4-Pole Frame
Sr.No. kW/HP CSCR CSIR CSR CSR
1
2
3
4
5
6
0.18/0.25
0.37/0.5
0.55/0.75
0.75/1.0
1.1/1.5
1.5/2
71
80L
80L
80L
90L
100L
80L
80L
90L
90L
90L
100L
63
71
71
80L
90L
90L
71
80L
80L
80L
90L
100L
3
5.0 Mechanical Features
4
Sr. No. Features Optional
Motor frames from 63 to 112 frame are made of Aluminum
pressure die cast bodies & 132S to 355L frames are made of
cast iron or M.S. fabricated.
63 to 90L frames are made of Aluminum pressure die cast.
All covers are with integral bearing housing bores.
flanges are . All
flanges are with integral bearing housing bores.
Construction :
63 to 112 frame - Aluminum
132 to 180 frame - Pressed sheet metal / Cast Iron
200 to 355 frame-
All T. Boxes can be rotated in a step of 90 through 360 for
desired direction of cable entry.
Please see dimensional table for T.Box position.
Cable Gland holes are B.S. conduit threading.
For sizes & no. of entries please refer to dimensional table.
Motor shafts are made of Carbon Steel as per
IS: All shafts have
threaded center hole as per DIN-332 standard.
Key & keyways on shaft are made as per IS:2048
63 to 225 frame motors have double shielded deep
groove ball bearing (single row).
250 to 355L frames motors have open type deep groove ball
(See Table No. A)
to 225 frame motors are with high temperature pre-greased
bearings. Online greasing arrangement is provided for motors
in 250 to 355L frames.
63 to frame are with V ring seals
to 355L frame are with Oil Seal
63 to 225 frames motors are suitable for both vertical and
horizontal mounting arrangement
Foot mounting motors : B3, B6, B7, B8, V5 & V6
Flange (D Type Flange) Mounting motors : B5, VI, V3, B35,
V15 & V36
Flange (C Type Flange) Mounting motors : B14, V18, V19,
B34, V58 & V69
250 to 355L frame motors are suitable for horizontal
mounting only (B3,B6,B37,B8,B5 & B35)
IP : 55
63 to 90L frames in Aluminum PDC/GDC
100 to 355L
frames flanges are in CI only.
PDC/GDC
Pressed sheet metal / Cast Iron
° °
40C8/45C8
2073 OR as per BS 970 En 8/EN8D.
M
Prelubricated for life
Bearing on both end
63 to 112 frame motors are with medium temp. Pregreased
132
with H. T. grease.
225 .
250 and felt.
std.
Standard
Frames
End Covers
Flanges-
D Type/C Type
Terminal Box
Cable Entry
Position
T.Box Position
Cable Gland
Shaft
Bearings
Lubrication
V Ring Seals
Oil Seals
Mounting
Arrangement
Degree of
Protection
Noise Level
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Motors frames offered in Al.
pressure die cast can be offered
in cast iron also.
63 to 90L frames can be offered in
cast iron also.
Special flanges can be offered.
63 to 90L frames flanges can be
offered in CI
Terminal box with special material &
special design can be offered on
request.
---
---
Cable glands of other conduit
threading like PG type/Metric
type can be offered.
Shaft with other material like
AISI-400, AISI-300, En 24 with heat
treatment can be offered. Speical
keys & keyways can be offered.
Angular Contact ball bearings,
taper roller bearings, spherical roller
bearings, cyl. roller bearings, Insulated
bearings can be offered. In 63 to 160
frame open bearing can be given.
Motors with greasing arrangement
in 63 to 225 frame can be offered.
Motors with oil seals can be offered.
63 to 160 frame motor with oil seal can be given
For vertical mounting motors in
250 to 355L frame contact LHPL.
IP :44, IP : 54, IP : 56, IP57, IP:65,
IP:66, IP67, IP68 can be given
Motors with low noise level canbe offered.
Precision class of vibration can
be offered.Flame-proof , Non-sparking &Cooling Tower motors
(b)
All other motors
Anti Corrosive Epoxy Paintof RAL 7015 Slate Grey Shade.
Anti Corrosive Polyurethine Paintof RAL 7015 Slate Grey Shade.
Vibration levels are maintained as per normal class of
IS : 12075. (See Table No. C)
Noise level of motors conform to IS:12065 specifications.
(See Table No. B)
VibrationLevel/Severity
Paint (a)
Other types of Colors & Shades also
can be given as per standards.
(c)
Cooling Tower motorsAnti Corrosive Epoxy PaintBlue M & P
Table No. - A
Frame wise bearing sizes
Table No. - B
Limiting Mean Sound Power Level Lw in dB (A)
for airborne noise emitted by rotating electrical machines
Frame Size
DE
Bearing No.
NDE
63
71
80
90 S/L
100 L
112 M
132 S/M
160 M/L
180 M
200 L
225 S/M
250 M
280 S/M
315 S/M/L
355 S/M/L
6201 ZZ
6203 ZZ
6204 ZZ
6205 ZZ
6206 ZZ
6306 ZZ
6308 ZZ C3
6309 ZZ C3
6310 ZZ C3
6312 ZZ C3
6313 ZZ C3
6314 C3
6318 C3
6319 C3
6322 C3
6201 ZZ
6203 ZZ
6204 ZZ
6304/6205 ZZ
6206 ZZ
6206 ZZ
6208 ZZ C3
6209 ZZ C3
6210 ZZ C3
6312 ZZ C3
6313 ZZ C3
6214 C3
6316 C3
6219 C3
6322 C3
Protection
Enclosure
Ratings in kV
IP
55
IP
55
IP
55
IP
55
IP
55
IP
55
Rated Speed (rev./min.)
960 & below 961-1320 1321-1900 1901-2360 2361-3150 3150-3750
Above Up to
--
1.1
2.2
5.5
11
22
37
55
110
220
1.1
2.2
5.5
11
22
37
55
110
220
630
76
79
82
85
89
91
92
96
100
102
79
80
84
88
93
95
97
101
104
106
80
83
87
91
96
97
99
104
106
109
83
87
92
96
98
100
103
105
108
111
84
89
93
97
101
103
105
107
110
112
88
91
95
100
103
105
107
109
112
114
Shaft center HT,
H in mm
Range of speed
class of
vibration severity
Normal
Precision A
Precision B
Precision C
Shaft center Ht,
H in mm
Pole
Speed, rpm
Class of vibration
serverity
Normal
Precision A
Precision B
Precision C
63 to 132 160 to 225 Above 225
600 to 1500 Above 1500 &up to 3000
600 to 1500 Above 1500 &up to 3000
600 to 1500 Above 1500 &up to 3000
RMS value of vibration velocity, mm/s
1.8
0.71
0.45
0.28
1.8
0.71
0.45
0.28
1.8
0.71
0.45
0.28
1.8
1.12
0.71
0.45
2.8
--
--
--
4.5
--
--
--
Vibration Severity
63 to 132 160 to 225 Above 225
8
750
6
1000
4
1500
2
3000
8
750
6
1000
4
1500
2
3000
8
750
6
1000
4
1500
2
3000
RMS value of vibration displacement, Microns
64
24
16
10
48
18
12
8
32
12
8
5
16
6
4
2.5
64
24
16
10
48
18
12
8
32
2
8
5
25
10
6
4
100
--
--
--
75
--
--
--
50
--
--
--
42
--
--
--
Table No. - C
Vibration Levels
5
FrameSize
HCONT. C A AB HA OK B BB ADMAX
OAC OD E F G GA TH LMAX
CG XNos.
For BrakeMotor
T.BoxPosition
63
63
71
71
80
80
90
90
90
90
100
100
112
112
132
132
132
160
160
180
180
200
225
225
225
225
250
250
280
280
280
280
315
315
315
315
315
315
355
355
355
355
355
355
CI
AL PDC
CI
AL PDC
CI
AL PDC
CI
AL PDC
CI
AL PDC
CI
AL PDC
CI
AL PDC
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
40
40
45
45
50
50
56
56
56
56
63
63
70
70
89
89
89
108
108
121
121
133
149
149
149
149
168
168
190
190
190
190
216
216
216
216
216
216
254
254
254
254
254
254
100
100
112
112
125
125
140
140
140
140
160
160
190
190
216
216
216
254
254
279
279
318
356
356
356
356
406
406
457
457
457
457
508
508
508
508
508
508
610
610
610
610
610
610
120
118
132
133
151
153
170
170
170
170
200
195
230
172
256
256
256
304
304
340
340
385
348
348
440
440
500
500
540
540
540
540
620
620
620
620
620
620
730
730
730
730
730
730
8
8
9
9
10
12
10
14
10
13
13
15
15
12
16
16
16
26
26
26
26
35
35
35
35
35
43
43
43
43
43
43
50
50
50
50
50
50
51
51
51
51
51
51
7
7
7
7
10
10
10
10
10
10
12
12
12
12
12
12
12
15
15
15
15
19
19
19
19
19
24
24
24
24
24
24
28
28
28
28
28
28
28
28
28
28
28
28
80
80
90
90
100
100
100
100
125
125
140
140
140
140
140
178
178
210
254
241
279
305
286
286
311
311
349
349
368
368
419
419
406
406
457
457
508
508
500
500
560
560
630
630
97
97
112
110
124
124
120
125
145
146
170
172
170
202
167
205
245
260
304
318
318
350
370
370
370
370
425
425
490
490
490
490
600
600
600
600
600
600
780
780
780
780
780
780
121
105
117
117
122
110
158
160
158
137
170
174
185
179
203
203
203
233
233
256
256
313
370
370
370
370
412
412
442
442
442
442
524
524
524
524
524
524
626
626
626
626
626
626
116
116
140
140
158
158
178
178
178
178
208
208
224
214
257
257
257
312
312
357
357
380
446
446
446
446
485
485
540
540
540
540
625
625
625
625
625
625
745
745
745
745
745
745
11j6
14j6
19j6
24j6
28j6
38k6
42
48
55m6
60
65
80
65
80
80
0
11j6
14j6
19j6
24j6
24j6
24j6
28j6
28j6
28j6
38k6
38k6
k6
42k6
k6
48k6
55m6
m6
55m6
60m6
60m6
65m6
65m6
75m6
65m6
75m6
65m6
80m6
m6
m6
m6
m6
80m6
100m6
m6
10 m6
80m6
100m6
23
23
30
30
40
40
50
50
50
50
60
60
60
60
80
80
80
110
110
110
110
110
110
140
110
140
140
140
140
140
140
140
140
170
140
170
140
170
170
210
170
210
170
210
4
4
5
5
6
6
8
8
8
8
8
8
8
8
10
10
10
12
12
14
14
16
16
18
16
18
18
18
18
20
18
20
18
22
18
22
18
22
22
28
22
28
22
28
8.5
11.0
15.5
20.0
20.0
24.0
24.0
33.0
33.0
37.0
37.0
42.5
42.5
49.0
49.0
53.0
49.0
53.0
53.0
58.0
58.0
67.5
58.0
7.5
58.0
71.0
58.0
71.0
58.0
71.0
71.0
90.0
71.0
90.0
71.0
90.0
8.5
11.0
15.5
20.0
20.0
24.0
24.0
33.0
6
12.5
16.0
21.5
27.0
27.0
31.0
31.0
41.0
41.0
45.0
45.0
51.5
51.5
59.0
59.0
64.0
59.0
64.0
.0
79.5
69.0
85.0
69.0
85.0
106.0
85.0
106.0
85.0
106.0
12.5
16.0
21.5
27.0
27.0
31.0
31.0
41.0
64.0
69.0
69
79.5
69.0
69.0
85.0
85.0
M5
5
6
8
8
10
10
12
12
16
16
16
16
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
24
20
24
20
24
M
M5
M5
M
M6
M
M
M8
M8
M
M
M10
M10
M
M
M12
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
218
254
285
341
356
396
448
500
623
667
721
721
800
218
254
285
321
370
389
405
463
525
860
820
900
860
990
938
1075
1033
1075
1037
1090
1065
1243
1218
1243
1218
1524
1491
1524
1491
1524
1491
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-2
3/4"-2
3/4"-2
1"-2
1"-2
1"-2
1"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
21/2"-2
21/2"-2
21/2"-2
21/2"-2
21/2"-2
21/2"-2
--
276
329
329
380
380
432
--
452
427
495
495
511
580
629
655
760
803
842
842
963
--
595
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
RHS
RHS
TOP
RHS
RHS
RHS
RHS
RHS
RHS
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
RHS
TOP
RHS
RHS
RHS
RHS
RHS
RHS
RHS
RHS
TOP
63
63
71
71
80
80
90S
90S
90L
90L
100L
100L
112M
112M
132S
132M
132M(N)
160M
160L
180M
180L
200L
225S(2P)
225S(4,6,8 P)
225M(2P)
225M(4,6,8 P)
250M (2P)
250M (4,6,8 P)
280S (2P)
280S(4,6,8 P)
280M (2 P)
280M (4,6,8 P)
315S (2 P)
315S (4,6,8 P)
315M (2 P)
315M (4,6,8 P)
315L (2 P)
315L (4,6,8 P)
355S (2 P)
355S (4,6,8 P)
355M (2P)
355M (4,6,8 P)
355L (2 P)
355L (4,6,8 P)
Table No. - 03
For 10Motor
6.0 Dimensions of Foot Maunted Motors (B-3 Mounting) as per IS : 1231(Standard, Brake, Non-sparking & Crane, Hoist duty motors)
6
LAD
--
106
129
129
135
151
145
--
145
165
162
162
175
179
202
202
202
233
233
256
256
313
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
302
--
347
--
--
386
--
429
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
LAD
--
--
--
119
--
114
--
--
159
--
152
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
FrameSize
FlangeNo.
F
F
F
F1
75C
F75C
85C
F85C
100C
F100C
15C
F115C
F115C
F115C
F130C
F130C
F130C
F130C
F165C
F165C
F165C
75
75
85
85
100
100
115
115
115
115
130
130
130
130
165
165
165
60
60
70
70
80
80
95
95
95
95
110
110
110
110
130
130
130
90
90
105
107
120
120
140
140
140
140
160
160
160
160
196
196
196
M5
M6
M6
M8
M8
M8
M8
M12
M12
M5
M6
M6
M8
M8
M8
M8
M12
6
6
8
8
8
8
10
10
10
10
10
10
10
10
14
14
14
2.5
2.5
2.5
2.5
3
3
3
3
3
3
3.5
3.5
3.5
3.5
3.5
3.5
3.5
120
105
115
115
125
110
160
160
160
160
158
175
185
180
210
210
210
116
116
140
140
158
158
178
178
178
178
208
208
225
215
260
260
260
11j6
14j6
19j6
24j6
24j6
28j6
28j6
38k6
38k6
11j6
14j6
19j6
24j6
24j6
28j6
28j6
38k6
23
23
30
30
40
40
50
50
50
50
60
60
60
60
80
80
80
4
4
5
5
6
6
8
8
8
8
8
8
8
8
10
10
10
8.5
8.5
11
11
15.5
15.5
20
20
20
20
24
24
24
24
33
33
33
12.5
12.5
16
16
21.5
21.5
27
27
27
27
31
31
31
31
41
41
41
M5
M5
M6
M8
M8
M10
M10
M12
M12
M5
M5
M6
M8
M8
M10
M10
M12
218
218
254
254
285
285
320
340
345
355
405
395
405
430
460
500
525
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-2
3/4"-2
3/4"-2
276
276
325
325
380
380
435
426
454
424
510
495
510
562
586
629
655
121
117
129
125
127
146
152
160
152
164
158
162
171
179
202
202
202
63
63
71
71
80
80
90S
90S
90L
90L
100L
100L
112M
112M
132S
132M
132M(N)
Table No. - 04
j6ON TD T AD
MAXOACOM
0.3OD E F G GA TH L
MAXCE XNos.
For BrakeMotor
L
--
--
--
119
--
--
--
--
152
--
152
--
--
--
--
--
--
OP
--
--
--
302
--
--
--
--
395
--
435
--
--
--
--
--
--
S
AD L
For 10Motor
7.0 Dimensions of Face Mounted Motors (B-14 Mounting) as per IS: 2223
(Standard, Brake, Non-sparking & Crane, Hoist duty motors)
AD
OM
ON
OP
CG
TH
GA
G
G
OD
TD
E
T
L
OA
C
7
AD
Cont.
CI
AL.PDC
CI
AL.PDC
CI
AL.PDC
CI
AL.PDC
CI
AL.PDC
CI
AL.PDC
CI
AL.PDC
CI
CI
CI
CE - Cable entry in BSC
1/2
1/2
Table No. - 05
FrameSize
FlangeNo.
F115B
F115B
F130B
F130B
F165B
F165B
F165B
F165B
F165B
F165B
F215B
F215B
F215B
F215B
F265B
F265B
F265B
F300B
F300B
F300B
F350B
F400B
F400B
F500B
F500B
F500B
F500B
F600B
F600B
F740B
F740B
115
115
130
130
165
165
165
165
165
165
215
215
215
215
265
265
265
300
300
300
350
400
400
500
500
500
500
600
600
740
740
95
95
110
110
130
130
130
130
130
130
180
180
180
180
230
230
230
250
250
250
300
350
350
450
450
450
450
550
550
680
680
140
140
160
160
200
200
200
200
200
200
250
250
250
250
300
300
300
350
350
350
400
450
450
550
550
550
550
660
660
800
800
10 X 4
10 X 4
10 X 4
10 X 4
12 X 4
12 X 4
12 X 4
12 X 4
12 X 4
12 X 4
15 X 4
15 X 4
15 X 4
15 X 4
15 X 4
15 X 4
15 X 4
19 X 4
19 X 4
19 X 4
19 X 8
19 X 8
19 X 8
19 X 8
19 X 8
19 X 8
19 X 8
24 X 8
24 X 8
24 X 8
24 X 8
3
3
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
6
6
6
6
10
10
10
10
11
11
11
11
11
11
12
12
12
12
13
13
13
14
14
14
16
16
16
19
19
22
22
22
22
25
25
10
10
10
20
16
16
22
22
22
22
20
22
23
18
47
47
47
54
54
72
71
71
71
65
65
50
50
50
50
45
45
120
105
115
115
125
110
160
160
160
160
158
175
185
180
210
210
210
230
230
255
340
375
375
410
410
430
430
520
520
625
625
116
116
140
140
158
158
178
178
178
178
208
208
225
215
260
260
260
312
312
360
382
445
445
485
485
540
540
625
625
745
745
11j6
11j6
14j6
14j6
19j6
19j6
24j6
24j6
24j6
24j6
28j6
28j6
28j6
28j6
38k6
38k6
38k6
42k6
42k6
48k6
55m6
55m6
60m6
60m6
65m6
65m6
75m6
65m6
80m6
80m6
100m6
23
23
30
30
40
40
50
50
50
50
60
60
60
60
80
80
80
110
110
110
110
110
140
140
140
140
140
140
170
170
210
4
4
5
5
6
6
8
8
8
8
8
8
8
8
10
10
10
12
12
14
16
16
18
18
18
18
20
18
22
22
28
8.5
8.5
11
11
15.5
15.5
20
20
20
20
24
24
24
24
33
33
33
37
37
42.5
49
49
53
53
58
58
67.5
58
71
71
90
12.5
12.5
16
16
21.5
21.5
27
27
27
27
31
31
31
31
41
41
41
45
45
51.5
59
59
64
64
69
69
79.5
69
85
85
106
M5
M5
M5
M5
M6
M6
M8
M8
M8
M8
M10
M10
M10
M10
M12
M12
M12
M16
M16
M16
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M24
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-1
3/4"-2
3/4"-2
3/4"-2
1"-2
1"-2
1"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2"-2
2 -2
2 -2
---
---
---
119
----
---
---
152
---
152
---
---
---
---
---
114
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
276
276
325
325
380
380
435
426
456
424
497
497
510
553
629
760
803
725
--
595
655
--
--
--
--
--
--
--
--
--
--
63
71
80
90S
90L
100L
112M
132S
132M
132M (N)
63
71
80
90S
90L
100L
112M
160M
160L
180M/L
200L
225S/M (2P)
225S/M (4,6,8P)
250M (2P)
250M (4,6,8P)
280S/M (2P)
280S/M (4,6,8P)
315S/M/L (2P)
315S/M/L (4,6,8P)
355S/M/L (2P)
355S/M/L (4,6,8P)
j6 T LA LD ADMAX
OM OD E F G GA TH CEX
Nos.
For SinglePhaseMotor
ForBrakeMotor
ADL LAD
---
---
---
302
---
348
---
---
395
---
435
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
121
117
129
125
127
146
152
160
152
164
158
162
189
179
202
202
202
233
233
835
--
--
--
--
--
--
--
--
--
--
--
OP
8.0 Dimensions of Flange Mounted Motors(B-5 Mounting) as per IS : 2223
GA
G
F
OP
OM
OS
AD
ON
OD
TLD
LA
L
E
OA
C
8
Cont.
CI
AL.PDC
CI
AL.PDC
CI
AL.PDC
CI
AL.PDC
CI
AL.PDC
CI
AL.PDC
CI
AL.PDC
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
CI
OS X NO. OAC
218
218
254
254
285
285
320
340
370
355
405
395
405
430
460
500
525
620
660
720
780
860
820
988
938
1075
1045
1240
1245
1570
1600
LMAX
0.3 ON
CE - Cable entry size in BSC
Frame Size
63
71
80
90
100
112
132
160
180
200
225
250
280
315
355
Table No. - 06Permissible Radial and Axial load on Motor(At the center of extension (Std.) including weight of the pulley)
The radial load for a given motor depends on the type and size of pulley/pinion chosen and type of driven machine. Radial loadcan be calculated using the following formula.
p =a x 973 x kWRPM x D/2
+ W Where, a = Belt Factor 2 to V belts3for flat belts
kW = Output of the motor in kW.RPM = Speed of the motor in Rev./Min.D = Dia. of pulley in meters.W = Weight of the pulley in kg.
It is recommended that the mounting of pulley/pinion be such that the load acts at the middle of extension of the shaft. For radialloads other than those recommended in Table No. 06, customers are advised to consult LHP for maximum allowable loads.
30
35
50
55
70
95
150
260
325
425
450
600
650
700
600
30
35
60
55
80
110
175
300
350
500
600
800
1600
1800
2000
30
35
60
65
80
110
200
325
400
575
650
900
1800
1900
1500
30
35
60
75
100
110
210
350
400
575
650
900
1800
2000
600
10
12
20
25
35
40
50
70
80
100
100
110
120
130
150
52 x 30
60 x 40
100 x 50
125 x 60
150 x 80
200 x 100
225 x 125
275 x 140
315 x 160
355 x 200
400 x 200
400 x 200
450 x 250
500 x 280
550 x 300
Synchronous RPM & Radial Load in Kg.
3000 1500 1000 750
Permissible AxialLoad in Kg.
Recommended Pulley SizeDia.x Width (D x W) in mm.
9.0 Permissible radial load for Standard Motors
9
Sr. No. Features
10.0 Electrical Features
Standard Optional
1. Supply voltage and frequency 415 _ 10% and 50 Hz _ 5% with combinedvariations of _ 10%
+ +
+Voltage up to 660V AC and frequencyfrom 5Hz to 120 Hz
2. Winding and insulation class Core material is of low loss magneticsilicon steel.Winding wound with polyester enameledcopper wire and with F class insulatingmaterial and vacuum impregnated withclass 155 (F) impregnating resins.
High grade steel and insulation classH can be given on request. And EpoxyGel coat provided on winding.
3. Rotor Aluminum die cast rotor dynamicallybalanced with half key to have low vibration.
Copper brazed Rotorscan be given on request.
4. Starts 5 to 7 seconds for two consequent startsfrom cold condition.
Other requirement can be given on
request. Customer shall specify GDspeed, period of acceleration,
speed torque curve of equipment andmethod of breaking.
2
of load
5. Duty Continuous (S1) Other duties S2 to S8 can be given onrequest
6. Starting method Up to 100 Frame - DOL Starting (3 Pin T. Block)Above 100 Frame - Star Delta starting(6 pin T. Block)* However, motors above 100 Frame can beused for DOL starting by making suitableconnection.
Up to 100 Frame - Start delta(6 pin T. Block)
7. Direction of rotation Bi-directional. ----
8. Earthing Provided on frame and inside the terminal box Can be given as per requirement.
9. Overload Withstood 160% of rated torque for 15 seconds. Other requirement can be given onrequest.
10. Service factor 1.0 Other service factor can be given onrequest
11. Accessories ---- BTD, Thermistor/space heater,Thermotrip /Winding RTD'S can begiven on request
10.1 Permissible temperature rise :Standard LHP motors are manufactured with class Finsulation and temperature rise restricted to class Binsulation.
10.2 Derating factors :The rating of motor is reduced when ambient temperatureexceeds 40 C and/or the altitude of the site is more than1000 meters above sea level.
0
Class ofInsualtion
B
F
H
130
155
180
80
105
125
75
100
120
70
95
115
60
85
105
40 45 50
Max.permissibleTemp. Limit C
0
Max. Permissible Temp. rise forwindings at Amb. Temp. in C
0
60
Ambienttemp. rise
40
45
50
60
100
98
96
90
Up to 1000
2000
3000
4000
Up to
Up to
Up to
% outputof motor
Altitude abovesea level meters
% outputof motor
100
95
85
77
10
10.3 Guidelines for Motors Protection fuse rating
The motors are to be provided with back up fuse protection of suitable ratings in addition to starters (D.O.L. or Star/Delta)being used to protect motors from overload and under voltage. The given below gives general guidelines for selection offuse ratings.
Table No. - 07 Fuse Rating
D.O.L. Starting
O/P Rating
Average Valuein AMPS
Fuse Rating
Bi-MetalRelay Range
KW
HP
0.37
0.5
1
4
0.5-1
0.55
0.75
1.3
6
1-2
0.75
1
1.9
6
1-2
1.1
1.5
2.6
6
1.5-3
2.2
3
4.8
16
3-6
3.7
5
7.8
16
6-12
7.5
10
15
25
10-16
9.3
12.5
18
32/35
18-24
11
15
21
32/35
18-24
15
20
27
50
16-32
18.5
25
33
63
24-45
22
30
39
63
24-45
30
40
53
100
32-63
37
50
65
100
50-90
45
60
78
160
50-90
55
75
96
160
70-110
75
100
131
200
90-135
90
125
156
250
140-170
5.5
7.5
11.2
25
6-12
Star-Delta Starting
O/P Rating
Full Load Current
Line
Phase
Overload Relay
Range Fuse Rating
KW
HP
2.2
3
4.8
2.8
1.5-3
10
3.7
5
7.8
4.5
3-6
16
5.5
7.5
11.2
6.5
4-8
16
7.5
10
15
9
6-12
25
9.3
12.5
18
11
6-12
25
11
15
21
12.7
10-16
25
18.5
25
33
20.2
18.24
50
22
30
39
23.2
12.24
63
30
40
53
30.6
16-32
63
37
50
65
37.5
24-45
80
45
60
78
46.4
32-63
100
55
75
96
54.5
32.63
125
75
100
131
74
50-90
160
90
125
156
88
80-100
200
110
150
185
107
70-110
200
132
180
220
127
90-135
250
15
20
27
16.8
18-24
50
1. The abov eare recommended values for H.R.C. delayed action fuse for direct on line starting
11
1.5
2
3.7
10
2-4
Rated Output Frame
Size
0.25
0.33
0.5
0.75
1
1.5
2
3
5
7.5
7.5
10
12.5
15
15
20
25
30
40
50
60
75
100
120
150
170
180
215
270
335
425
63
71
71
71
80
80
90S
90L
100L
112M
132S
132S
132M
132M
160M
160M
160L
180M
200L
225M
250M
280S
280M
315S
315M
315L
315L
355L
355L
200L
315M
0.60
0.70
1.10
1.45
1.70
2.55
3.30
4.60
7.2
11.00
10.7
13.8
17.00
20.00
20.00
27.50
33.00
38.00
52.00
63.00
75.00
92.00
126
158
183
203
218
260
320
398
502
2730
2820
2800
2800
2800
2860
2860
2860
2880
2900
2900
2900
2900
2900
2900
2920
2910
2940
2940
2955
2950
2965
2965
2970
2970
2970
2970
2980
2980
2982
2982
0.06
0.09
0.13
0.19
0.26
0.38
0.51
0.75
1.25
1.85
1.84
2.52
3.13
3.70
3.70
5.01
6.20
7.30
9.95
12.44
14.87
18.09
24.70
29.65
36.11
41.04
43.33
52.35
65.44
81.7
102.9
400
430
490
520
600
590
580
650
600
650
650
650
650
650
650
650
680
650
620
700
650
700
700
700
700
700
700
700
700
700
700
240
220
250
230
240
240
240
240
220
220
200
200
210
200
200
220
220
230
220
270
200
210
190
190
180
180
180
180
180
160
160
310
320
320
300
320
320
300
300
300
280
250
250
280
300
300
300
300
300
300
300
300
300
270
270
270
270
270
270
270
280
280
64
70
66.1
69.1
72.1
75
77.2
79.7
82.7
84.7
84.7
86
87
87.6
87.6
88.7
89.3
89.9
90.7
91.2
91.7
92.1
92.7
93
93.3
93.4
93.5
93.8
94
94
94
62
68
64.1
64.4
70.1
72
76.2
77.2
80.7
82.7
84.7
86
87
87.6
85.6
85.7
86.8
89.9
89.7
90.7
91.2
91.1
92.7
93
93.3
93.4
93.3
93.8
94
94
94
56
62
58.1
60.1
65.1
69
73.2
75.7
75.7
76.7
82.2
86
83.3
84.2
83.6
83.7
84.8
86.9
87.7
89.7
88.2
90.1
91.2
91.5
91.8
91.9
92
92.3
92.5
91.5
92.5
0.68
0.71
0.71
0.76
0.85
0.80
0.81
0.83
0.86
0.82
0.84
0.88
0.87
0.87
0.87
0.85
0.87
0.89
0.88
0.89
0.91
0.90
0.89
0.85
0.89
0.92
0.90
0.91
0.92
0.93
0.93
0.65
0.65
0.65
0.72
0.79
0.74
0.78
0.79
0.83
0.80
0.83
0.83
0.85
0.84
0.82
0.81
0.85
0.85
0.86
0.88
0.90
0.89
0.85
0.81
0.83
0.88
0.86
0.89
0.87
0.90
0.90
0.54
0.55
0.59
0.67
0.73
0.72
0.72
0.69
0.76
0.75
0.75
0.74
0.79
0.76
0.76
0.77
0.77
0.79
0.80
0.84
0.89
0.85
0.77
0.77
0.75
0.80
0.78
0.87
0.88
0.85
0.85
0.0009
0.0015
0.0015
0.0021
0.0036
0.0036
0.0073
0.0089
0.022
0.028
0.052
0.068
0.080
0.085
0.17
0.22
0.28
0.42
0.64
0.75
0.91
1.8
6.63
8.18
11.55
12.7
13.89
14.3
18.87
23.4
29.7
6/10
8/14
8/14
8/14
12/18
12/18
18/25
18/25
30/40
40/50
55
58
65
67
82
105
125
184
240
---
295
595
725
775
1000
1150
1250
1400
1650
2150
2150
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
5.5
7.5
9.3
11
11
15
18.5
22
30
37
45
55
75
90
110
125
132
160
200
250
315
kW HP
Rated
Current
Amps
Rated
Speed
RPM
Rated
Torque
kgm
Starting
Current
% of
Rated
Current
Starting
Torque
% of
Rated
Torque
Peak
Torque
% of
Rated
Torque
Approx.
Net
Weight
kg
Rotor
GD
kg m sq
2Efficiency %
100% 75% 50% 100% 75% 50%
Power Factor
Table No. - 08
Electrical performance figures of Standard and Brake TEFC Foot, Flange & Face Mounted Three PhaseAt 415 V _ 10%, 50 Hz _ 5% Two Pole Induction Motor+ +
Electrical Performance Figures
12
AL/CI
Note :
1. Motors in 63 to 112M frame with die cast Aluminum & in 132 to 355 frame in cast iron construction.2. Motors in frame 63 to 112M frame can be offered with cast iron construction on request at extra
Rated Output Frame
Size
0.16
0.25
0.33
0.5
0.75
1
1.5
2
3
4
5
7.5
10
12.5
12.5
15
20
25
30
40
50
60
75
100
120
150
170
180
215
250
270
300
335
425
63
71
71
80
80
90S
90L
100L
112M
132S
132M
132M
160M
160M
160L
180M
200L
225M
250M
280S
280M
315S
315M
315L
315L
355L
355L
63
100L
180L
225S
315M
315L
355L
0.40
0.65
0.70
1.00
1.40
1.80
2.50
3.40
4.80
6.40
7.70
11.00
14.50
20.00
18.50
22.00
28.50
34.00
40.00
54.00
66.00
78.00
96
131
156
191
215
227
271
314
339
378
421
531
1325
1340
1360
1390
1420
1410
1400
1410
1430
1410
1440
1440
1450
1450
1450
1440
1460
1460
1460
1465
1470
1470
1475
1480
1480
1485
1485
1485
1485
1485
1485
1488
1488
1488
0.09
0.13
0.18
0.26
0.38
0.52
0.77
1.04
1.50
2.07
2.51
3.72
5.04
6.25
6.25
7.45
10.02
12.35
14.69
19.97
24.54
29.85
36.36
49.41
59.29
72.08
81.91
96.49
105.05
118.34
131.31
147
163.4
205.6
300
310
320
450
480
450
570
560
590
590
580
630
650
650
620
600
600
600
600
600
600
600
650
650
650
650
650
650
650
650
650
650
650
650
200
210
200
200
200
200
200
190
200
200
200
200
200
190
200
200
250
250
250
250
230
230
250
250
250
225
225
225
250
240
250
180
180
180
280
280
260
260
250
240
260
240
250
250
250
260
250
280
250
250
270
270
270
270
280
280
280
280
280
255
255
255
280
270
280
230
230
230
60
63
68
65.1
69.1
72.1
75
77.2
79.7
81.5
82.7
84.7
86
87.3
88.3
87.6
88.7
89.3
89.9
90.7
91.2
91.7
92.1
92.7
93
93.3
93.4
93.5
93.8
94
94
94.1
94
94
50
52
60
59.1
65.1
70.1
69
74.2
77.7
79.5
80.7
83.7
85
86.3
87.3
85.6
87.7
87.3
88.9
89.7
90.2
90.7
91.1
91.2
91.5
90.8
90.9
92.5
92.5
92.7
92.5
92.6
93
92.5
0.74
0.65
0.73
0.79
0.79
0.80
0.81
0.79
0.80
0.80
0.80
0.82
0.84
0.74
0.79
0.79
0.81
0.84
0.85
0.85
0.85
0.87
0.86
0.85
0.85
0.84
0.86
0.87
0.87
0.85
0.87
0.88
0.88
0.88
0.70
0.60
0.65
0.74
0.73
0.76
0.73
0.77
0.79
0.80
0.80
0.80
0.82
0.71
0.78
0.79
0.81
0.77
0.82
0.83
0.84
0.86
0.85
0.83
0.83
0.82
0.84
0.85
0.83
0.81
0.82
0.85
0.85
0.85
0.54
0.50
0.55
0.60
0.57
0.67
0.61
0.59
0.66
0.70
0.65
0.67
0.65
0.64
0.69
0.73
0.74
0.60
0.78
0.78
0.78
0.79
0.78
0.81
0.80
0.80
0.82
0.83
0.75
0.73
0.75
0.80
0.81
0.85
0.0014
0.0014
0.0034
0.0034
0.0077
0.0086
0.014
0.010
0.029
0.038
0.057
0.093
0.12
0.14
0.17
0.20
0.26
0.66
0.84
1.19
1.46
1.71
3.20
7.21
8.25
11.62
12.8
13.98
27.88
29.30
30.74
34.1
38.1
48.3
6/10
4/10
8/14
8/14
11/16
10/16
20/30
25/35
35/47
35/57
40/66
62
75
83
95
110
130
175
210
247
255
310
625
720
775
1000
1100
1225
1400
1650
1800
2000
2100
2150
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.7
5.5
7.5
9.3
9.3
11
15
18.5
22
30
37
45
55
75
90
110
125
132
160
180
200
225
250
315
kW HP
Rated
Current
Amps
Rated
Speed
RPM
Rated
Torque
kgm
Starting
Current
% of
Rated
Current
Starting
Torque
% of
Rated
Torque
Peak
Torque
% of
Rated
Torque
Approx.
Net
Weight
kg
AL/CI
Rotor
GD
kg m sq
2
Efficiency %
100% 75% 50% 100% 75% 50%
Power Factor
Table No. - 09Electrical performance figures of Standard and Brake TEFC Foot, Flange & Face Mounted Three PhaseAt 415 V _ 10%, 50 Hz _ 5% Four Pole Induction Motor+ +
54
56
68
64.1
68.1
72.1
75
77.2
79.7
81.5
82.7
84.7
86
87.3
88.2
86.6
87.7
88.3
89.9
90.7
91.2
90.7
92.1
92.2
92.5
93.3
93.4
93
93.5
94
94
94.1
94
93.5
13
Note :
1. Motors in 63 to 112M frame with die cast Aluminum & in 132 to 355 frame in cast iron construction.2. Motors in 63 to 112M can be offered with cast iron construction on request at extra cost.frame
Rated Output Frame
SizekW HP
Rated
Current
Amps
Rated
Speed
RPM
Rated
Torque
kgm
Starting
Current
% of
Rated
Current
Starting
% of
Rated
Torque
Torque
Peak
Torque
% of
Rated
Torque
Approx.
Net
Weight
kg
Al/CI
Rotor
GD
kg m sq
Efficiency %
100% 75% 50% 100% 75% 50%
Power Factor
Table No. - 10Electrical performance figures of Standard and Brake TEFC Foot, Flange & Face Mounted Three PhaseAt 415 V _ 10%, 50 Hz _ 5% Six Pole Induction Motor+ +
14
Note :
1. Motors in 63 to 112M frame with die cast Aluminum & in 132 to 355 frame in cast iron construction.2. Motors in 63 to 112M can be offered with cast iron construction on request at extra cost.frame
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30
37
45
55
75
90
110
132
160
250
0.25
0.33
0.5
0.75
1
1.5
2
3
5
7.5
10
12.5
15
20
25
30
40
50
60
75
100
120
150
180
270
335
240
240
250
260
280
280
290
250
250
280
250
250
300
300
300
280
250
250
260
230
255
255
255
280
200
200
71
71
80
80
90S
90L
100L
112M
132S
132M
160M
160L
160L
180L
200L
200L
225M
250M
280S
280M
315S
315M
315M
315L
355L
355L
0.70
1.00
1.40
1.80
2.10
3.00
3.70
5.20
8.00
12.00
15.50
19.00
21.00
28.00
34.00
41.00
55.00
67.00
80
97
131
157
191
229
351
434
900
890
900
900
950
940
930
945
960
950
960
960
970
960
980
980
980
980
980
980
985
985
985
985
988
990
0.27
0.36
0.40
0.60
0.77
1.14
1.57
2.27
3.76
5.64
7.62
9.45
11.06
15.23
18.41
21.89
29.85
36.81
44.77
54.72
74.62
89.09
108.88
130.66
196.57
245.2
370
340
320
320
400
400
400
400
450
540
600
650
650
650
600
620
600
600
600
650
650
650
650
650
650
650
190
190
190
190
200
200
190
190
190
230
200
220
220
230
230
230
210
210
230
200
225
225
225
230
160
160
60
60
63
67
70
72.9
75.2
77.7
80.9
83.1
84.7
87
86.4
87.7
88.6
89.2
90.2
90.8
91.4
91.9
92.6
92.9
93.3
93.5
94
94
50
50
62
63
89
66.9
66.2
76.7
79.9
82.1
83.7
86
85.7
86.7
87.6
88.2
89.2
89.3
89.4
90.9
91.1
91.7
92.3
92.5
90.5
92.5
0.65
0.60
0.58
0.63
0.70
0.70
0.75
0.74
0.79
0.76
0.79
0.78
0.84
0.84
0.84
0.82
0.84
0.84
0.85
0.85
0.86
0.85
0.86
0.87
0.84
0.85
0.58
0.58
0.55
0.58
0.64
0.60
0.67
0.68
0.75
0.76
0.73
0.74
0.75
0.81
0.79
0.78
0.80
0.80
0.82
0.81
0.82
0.81
0.82
0.83
0.81
0.82
0.48
0.52
0.51
0.54
0.57
0.52
0.59
0.62
0.69
0.72
0.64
0.62
0.62
0.71
0.73
0.72
0.74
0.74
0.73
0.73
0.74
0.73
0.70
0.75
0.72
0.73
0.0044
0.0044
0.0070
0.0093
0.016
0.020
0.032
0.072
0.13
0.17
0.43
0.58
0.66
1.03
1.43
1.57
2.30
3.60
8.01
9.89
14.12
17.0
18.98
29.94
37.5
46.6
7/10
7/10
10/16
12/18
16/26
25/35
33/45
44/55
62
75
81
135
144
187
233
245
310
625
720
805
1000
1180
1300
1400
2150
2170
56
58
63
66
69
68.9
72.2
77.7
80.9
83.1
84.7
87
86.4
87.7
88.6
89.2
90.2
90.3
91.4
91.4
92.1
92.4
93.3
93.5
93
93.5
Rated Output Frame
SizekW HP
Rated
Current
Amps
Rated
Speed
RPM
Rated
Torque
kgm
Starting
Current
% of
Rated
Current
Starting
Torque
% of
Rated
Torque
Peak
Torque
% of
Rated
Torque
Approx.
Net
Weight
kg
AL/CI
Rotor
GD
kg m sq
Efficiency %
100% 75% 50% 100% 75% 50%
Power Factor
Table No. - 11Electrical performance figures of Standard and Brake TEFC Foot, Flange & Face Mounted Three PhaseAt 415 V _ 10%, 50 Hz _ 5% Eight Pole Induction Motor+ +
15
2
Note : 1. Motors in 63 to 112M frame with die cast Aluminum & in 132 to 355 frame in cast iron construction.2. Motors in 63 to 112M can be offered with cast iron construction on request at extra cost.frame
0.25
0.33
0.50
0.75
1
1.5
2
3
5
5
7.5
10
15
20
25
30
40
50
60
75
100
120
150
180
270
80
80
90S
90L
100L
100L
112M
132S
132M
160M
160M
160L
180M
200L
225S
225M
250M
280S
280M
315S
315M
315L
315L
315L
355L
1.00
1.20
1.40
2.10
2.50
3.30
4.00
5.40
10.00
8.20
12.50
16.00
23.00
32.00
37.00
43.00
57.00
71
91
106
144
171
209
250
403
660
680
680
700
700
710
710
710
720
720
720
720
735
735
735
735
735
735
740
740
740
740
740
740
745
0.27
0.36
0.53
0.77
1.04
1.51
2.06
3.02
5.01
5.01
7.45
10.16
14.59
19.90
24.54
29.18
39.80
49.08
59.29
72.47
98.82
118.58
144.93
173.92
261.48
200
250
300
400
400
400
400
450
500
500
500
500
500
500
500
500
500
500
500
600
600
600
600
600
600
180
180
170
190
190
190
190
200
200
200
200
210
210
210
200
200
200
210
210
200
200
250
250
250
185
240
250
250
250
250
250
250
260
260
260
260
240
280
290
290
260
260
260
240
240
230
230
280
280
200
50
56
62
66
72
74
78
82
82
84
87
88
90
90
90
90
91
91.5
92
92.5
93
94
94
94.5
94.5
44
48
60
62
65
72
72
79
78
82
84
84
87
88
88
88
89
89
90.5
91
91.5
92
92.5
92.5
92.5
0.50
0.52
0.63
0.63
0.68
0.69
0.70
0.66
0.75
0.73
0.74
0.77
0.76
0.76
0.79
0.80
0.80
0.79
0.75
0.78
0.78
0.78
0.78
0.78
0.73
0.47
0.50
0.54
0.55
0.62
0.62
0.62
0.68
0.62
0.70
0.70
0.70
0.72
0.72
0.78
0.78
0.78
0.76
0.71
0.74
0.74
0.74
0.74
0.74
0.66
0.42
0.44
0.50
0.50
0.54
0.54
0.54
0.60
0.56
0.64
0.62
0.63
0.68
0.64
0.74
0.74
0.74
0.67
0.63
0.66
0.66
0.66
0.66
0.66
0.56
0.0089
0.0089
0.0158
0.0196
0.032
0.042
0.067
0.12
0.20
0.37
0.46
0.57
1.29
1.70
2.30
2.60
4.40
8.01
9.89
14.12
18.98
29.94
29.94
33.28
37.5
10/16
12/18
18/26
27/35
32/44
37/50
43/55
66
75
85
100
125
200
258
345
375
465
600
720
900
950
1130
1130
1130
2150
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.7
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
200
48
52
60
64
70
74
76
81
80
83
86
86
89
89
89
89
90
91.5
92
92.5
93
94
94
94.5
94.5
11.1 Salient Features
11.2 Construction
1. Simple construction and installation : The operation of the brake is fail-safe type i.e. Normally 'ON'. The brake is appliedwhen the power to the motor is cut off or power failure occurs. Being of simple and robust construction. these motors needvery little maintenance. In the rare event of failure it can be repaired easily and quickly. Spacial brake liners are used toensure that the braking torque remains constant throughout the use. Compensation for liner wear is very simple. Also thetorque adjustment is very easy. The breaking torque can be adjusted by rotating torque adjustment ring. The brake motorfacilitates easy replacement of armature disc in the event of wear and tear.
2. Manual Release is provided for brakes up to brakes up to 200 Frames. In case of power failure or in case of maintenance,the manual release can be pushed back for releasing the brake.
3. Dust-Protecting seal is provided for protection of brake liners form dust.4. The Switching Time of the brake motor is very fast, almost instantaneous.5. The brake motor is provided with the rectifier unit. Therefore, no separate D.C. Supply is necessary for energizing the brake
coil. Varistor is provided across the D.C. Terminals to protect the brake coil and rectifier against line and induced voltages,due to switching.
6. Normally 'OFF' type brakes can also be offered on request. These type of brakes are very compact in design & have highoperating reliability. The liners are made of special friction material & the brake is almost maintenance free.
7. A.C. Fail Safe brake motors can be offered on request.8. DC side switching only for our geared brake motors.
11.3 Working
In the event of power failure, the braking torque in applied by an axial force of several compression springs. Pressing thearmature plate against the rotor. The rotor is then pushed against the mounting flange or a suitable face.
11.4 Switching
Our Brake motors require D.C. supply voltage, (190VDC) which can be obtained through A.C. Or D.C. rectification. Normallyswitching is carried out on the A.C. side. However, for much faster engagement / disengagement time, switching is carried out onthe D.C. side for which a suitable arc suppressor and capacitor is a must to protect the coil and switching from high inductionvoltage engagements and for switching purpose, please refer to brake coil connection diagram. For hoisting and lift application,only DC side swithching is recommended.
11.5 Output Ratings
As per Table 02
11.6 Braking Torque
Braking-torque depends upon the output rating, speed and application of the motor. Therefore, customers are requested tocontact LHP for proper selection of the brake for intended application.
11.7 Dimensional Specifications
Please refer to table no. 3, 4, 5 for detailed dimensions of brake motors.
11.8 Connection Diagrams for Brake Coil
11.0 Brake Motors
16
R Y BC1
C2
UVW
MONITORTERMINALS
RECTIFIERBRAKECOIL
BRAKE SWITCHING ON A.C. SIDE
R Y BC1
UVW
MONITORTERMINALS
BRAKE SWITCHING ON D.C. SIDE
D. C.
BRAKECOIL
R Y BC1
C2
UVW
MONITORTERMINALS
RECTIFIERBRAKE COIL
BRAKE SWITCHING ON D.C. SIDE
The necessary torque for selecting the Brake size can be calculated by applying the
formula given below,
T=9550 x 0.75 x P
KxRPM
Where T= Torque in N.M.
P= Power of Motor in HP.
RPM = Speed of Motor per minute
K= Safety factor, which is to be considered depending on load & inertia on motor.
For Typical applications K shall be selected as per guidelines given below.
Load Condition Safety Factor (K)
2.0
2.5
3.0
3.0
2.0
Low masses, equal loading & non-intermittent operation
Low masses, light shock loading & intermittent operation
Medium & large masses, light shock loading and intermittent operation
For Lifts & Hoist applications (Vertical & down movement)
Long travel or cross travel in cranes.
Selection of Brake size recommended by LHPL
17
Period of cycle
Load
ElectricLosses
Temp
TIME
O Max.
N : Operation at Constant LoadO : Maximum Temp. attained
during duty cycle in C0
FIG. - 2
FIG. - 1
Load
ElectricLosses
Temp
O Max.
TIME
N
N : Operation at Constant LoadO : Maximum Temp. attained
12.1 Special Features
1. Ideal for frequent starts / stops and reversing reversing operations in material handling, lifts cranes, hoists and rolling mills.2. Positive locking between rotor and shaft is provided with a keyed joint.3. Motors can be supplied with electromagnetic fail-safe D.C. brakes.4. All crane duty motors are with D.O.L. Starting and F class Insulation.
12.2 Selection of Motors
The kilowatt requirement of the motor can be obtained by the following formula.1. For Horizontal Motion :
Where :P = Power required (kW)
P = F = Max. total load in kgV = Hoisting speed in Mtrs./Sec.n = O/A Eff. of the driving unit.
2. For Rotary Motion :Where :
P = M = Torque for movement in kg. m.N = Motor speed in RPM
Ensure the rated output of motor is greater than the power PL.Depending upon the duty classes usually required by the crane manufacturer as explained above, the motors are classified intothree classes of starting : 60 Stars / hr, 150 Starts / hr, 300 Starts / hr.LHP Motors are standardized such that they are suitable for all the three classes of starting.For purpose of thermal rating the equivalent duty is class S2 - 60 minutes.
F V
102
X
X n
M X N
975 X nkW
12.3 Classes of Duty & Duty Cycles
Motors are suitable for :A Continuous Duty (S1)B Short Time Duty (S2)C Intermittent Periodic Duty (S3)D Intermittent Duty with Starting & Electrical
Braking (S5)
1. Continuous DutyOperation of constant load of sufficient duration forthermal equilibrium to be reached.
Note : Crane Duty motors are suitable only forcontinuous duty for 1 hour.
2. Short Time DutyThe motor operated at a constant load for somespecified time which is then followed by periods of rest.The period for load is so short that the motor cannotreach its thermal equilibrium i.e. steady temp, risewhile the period for rest is so long that the motor temp.drops to the ambient temp. The simplified diagram forshort time duty is shown in Flg. 02. Standard short timerating are 10, 30 & 90 minutes.
12.0 Crane Duty Motors
18
N
3. Intermittent Periodic Duty
On intermittent duty the period of constant load & rest withmachine de-energised alternately. The load periods are too shortto allow the motor to reach its final thermal steady state value whileperiods of rest are also too small to allow the motor to cool down tothe ambient temp. The simplified load for this type of duty is shownin Fig. 3.
For evaluation of intensity of heating due to intermittent periodicloads, duty factor is used. The duty factor (also called as cyclicduration factor) is generally defined as the ratio of the heatingperiod to the period of whole cycle.
So, Cycle Duration Factor =N
N + R
4. Intermittent Periodic Duty with Starting
This type of duty consists of a sequence of identical duty cycles,each consisting of starting a period, the operation & rest period aretoo short to attain thermal equilibrium during cycle as shown inFig. 04.
In this duty, the stopping of the motor is obtained either by naturaldeacceleration after disconnection of the electric supply or bymeans of breaking such as mechanical brake which does notcause additional heating of the motor.
5. Intermittent periodic Duty with Starting & Breaking
This type of duty consists of sequence of identical duty cycles eachconsisting of a period of starting, a period of operation at constantload, a period of braking and a period of rest. The operating & restperiods are too short to obtain thermal equilibrium during one dutycycle shown in Fig. no. 4. In this duty the braking is rapid & iscarried out by electrical means.
The duty factor (CDF) =D + N + F
D + N + F + R
12.4 Dimensional Specification Data
12.5 Electrical Performance
Please refer to the table no. 3, 4 for detailed dimensions of crane duty motors.
Please refer to the table no. 12 & 13
19
Load
ElectricLosses
TIME
O Max.Temp
PERIOD OF CYCLE
N R
N : Operation at constant LoadR : Operation at rest &
de-energizedO : Maximum Temp. attained
during duty cycle in 0cX : Period of one cycle
FIG. - 3
FIG. - 4
PERIOD OF CYCLE
Load
ElectricLosses
Temp O Max.
TIME
D N R
D : Starting PeriodN : Operation under rated
conditionR : At rest & de-energizedO : Maximum Temp. attained
during duty cycle in Co
The cycleduration =factor
D + N
D + N + RPERIOD OF CYCLE
N R
Load
ElectricLosses
Temp
TIME
O Max.
D
FIG. - 5
D : Starting PeriodN : Operation under rated
conditionF : Braking periodR : At rest & de-energizedO : Maximum Temp. attained
during duty cycle in Co
Rated Output Frame
Size
0.18
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11.0
15.0
0.25
0.5
0.75
1.0
1.5
2.0
3.0
5.0
7.5
10.0
12.5
15.0
20.0
71
71
80
80
90S
90L
100L
112M
132S
132M
160M
160M
160L
0.82
1.60
2.00
2.60
3.70
4.60
6.00
9.20
12.50
17.00
19.00
22.50
32.00
880
880
880
900
950
920
920
920
940
920
960
910
950
0.28
0.41
0.61
0.81
1.13
1.59
2.33
3.92
5.70
7.95
9.45
11.79
15.39
300
300
300
300
300
350
450
400
500
500
600
600
600
200
200
200
200
200
210
210
200
210
200
220
240
230
300
300
300
300
300
300
300
300
300
300
300
300
300
60
58
65
71
74
74
74
78
82
82
86
85
88
0.51
0.55
0.59
0.57
0.56
0.61
0.69
0.72
0.75
0.75
0.79
0.80
0.74
0.0044
0.0044
0.007
0.011
0.016
0.020
0.042
0.077
0.13
0.19
0.49
0.49
0.66
7
7
12
14
25
27
37
46
62
80
88
100
125
kW HP
Rated
Current
Amps
Rated
Speed
RPM
Rated
Torque
kgm
Starting
Current
% of
Rated
Current
Starting
Torque
% of
Rated
Torque
Peak
Torque
% of
Rated
Torque
Approx.
Net
Weight
kg
Rotor
GD
kg m sq
Efficiency
%
Power
Factor
Rated Output Frame
Size
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.7
5.5
7.5
9.3
11.0
15.0
0.5
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10.0
12.5
15.0
20.0
71
71
80
80
90L
90L
100L
100L
112M
132M
132M
160M
160M
1.40
1.90
2.40
2.70
3.40
5.00
6.50
7.80
12.00
15.20
19.00
22.00
29.00
1320
1300
1320
1250
1380
1350
1410
1420
1390
1390
1420
1450
1450
0.27
0.41
0.55
0.86
1.06
1.59
2.07
2.54
3.86
5.26
6.39
7.40
10.09
300
300
250
400
450
450
600
600
500
500
500
500
500
240
200
200
200
200
220
200
220
200
200
220
230
200
300
300
300
300
300
300
300
300
300
300
300
300
300
62
62
70
71
74
76
80
82
84
84
86
86
88
0.59
0.65
0.62
0.80
0.83
0.81
0.80
0.80
0.76
0.82
0.79
0.81
0.82
0.0036
0.0040
0.0069
0.010
0.011
0.013
0.029
0.041
0.053
0.12
0.15
0.30
0.33
8
8
11
14
25
26
32
38
46
71
80
90
100
kW HP
Rated
Current
Amps
Rated
Speed
RPM
Rated
Torque
kgm
Starting
Current
% of
Rated
Current
Starting
Torque
% of
Rated
Torque
Peak
Torque
% of
Rated
Torque
Approx.
Net
Weight
kg
Rotor
GD
kg m sq
2Efficiency
%
Power
Factor
Table No. - 12Electrical performance figures of Crane duty, TEFC, Foot, Flange and Face Mounted Three PhaseAt 415 V, 50 Hz Four Pole Induction Motor
Table No. - 13Electrical performance figures of Crane duty, TEFC, Foot, Flange and Face Mounted Three PhaseAt 415 V, 50 Hz Six Pole Induction Motor
13.0 Dual Speed MotorsLHPL, developed Dual Speed Motor for polarity ratio - 2/4P, 4/8P, 6/8P,6/12P. The frame size outputs are confirmed subject to knowing :
a) Complete application detailsb) Duty cycle/loading cyclec) Method of brakingd) Load GD referred to motor shaft
Winding of dual speed motors : There are two types of winding techniques which are used in the motors :a) Tapped winding (Also called Dahlandar winding) : where the two speeds are in ratio of 2 to 1b) Separate windings : One for each speed, when the output speed is other than 2 to 1 ratio. The latter results in considerable reductionin output rating.
2
20
21
Sr. No. Parameters
Sr. No. Parameters
1
2
3
4
5
6
7
8
9
10
11
2 Pole - CSR
4 Pole - CSR
KW/HP
Pole
Frame
Full Load RPM
Rated Current
Power Factor
Full Load Torque
% Starting Torque/Full Load Torque
Bearing DE
Bearing NDE
Ref. Std.
0.18/0.25
4
71
1400
1.8A
0.84
0.125KGM
63%
6203
6203
IS:996
0.37/0.5
4
80
1400
2.5A
0.99
0.25KGM
45%
6204
6204
IS:996
0.55/0.75
4
80
1440
3.8A
0.99
0.373KGM
35%
6204
6204
IS:996
0.75/1
4
80
1400
5.2A
0.98
0.51KGM
40%
6205
6205
IS:996
1.1/1.5
4
90
1360
7A
0.99
0.78KGM
40%
6205
6205
IS:996
1.5/2
4
100
1410
11.5A
0.96
1.01KGM
40%
6206
6206
IS:996
KW/HP
Pole
Frame
Full Load RPM
Rated Current
Power Factor
Full Load Torque
% Starting Torque/Full Load Torque
Bearing DE
Bearing NDE
Ref. Std.
0.18/0.25
2
63
2800
1.8A
0.99
0.05KGM
50%
6201
6201
IS:996
0.37/0.5
2
71
2800
3A
0.98
0.127KGM
40%
6203
6203
IS:996
0.55/0.75
2
71
2800
3.8A
0.99
0.19KGM
40%
6203
6203
IS:996
0.75/1
2
80
2800
5.4A
0.99
0.24KGM
40%
6204
6204
IS:996
1.1/1.5
2
90
2900
8A
0.98
0.37KGM
40%
6205
6205
IS:996
1.5/2
2
90
2820
10A
0.92
0.5KGM
40%
6205
6205
IS:996
1
2
3
4
5
6
7
8
9
10
11
Electrical performance Figures of standard TEFC Foot, flange & Face Mounted,
Single phase at 230V, 50HZ, S1 duty, IP : 55, F Class, 40 C Amd.°
Table No. - 14
Table No. - 15
22
4 Pole - CSIR
4 Pole - CSCR
Sr. No. Parameters
1
2
3
4
5
6
7
8
9
10
11
KW/HP
Pole
Frame
Full Load RPM
Rated Current
Power Factor
Full Load Torque
% Starting Torque/Full Load Torque
Bearing DE
Bearing NDE
Ref. Std.
0.18/0.25
4
80
1400
2.4A
0.64
0.25KGM
200%
6204
6205
IS:996
0.37/0.5
4
80
1400
4.2A
0.65
0.25KGM
180%
6204
6205
IS:996
0.55/0.75
4
90L
1400
6A
0.81
0.38KGM
180%
6205
6205
IS:996
0.75/1
4
90L
1430
7A
0.71
0.51KGM
190%
6205
6205
IS:996
1.1/1.5
4
90L
1410
10A
0.77
0.76KGM
180%
6205
6205
IS:996
1.5/2
4
100L
1410
14A
0.76
1.03KGM
190%
6205
6205
IS:996
Sr. No. Parameters
1
2
3
4
5
6
7
8
9
10
11
KW/HP
Pole
Frame
Full Load RPM
Rated Current
Power Factor
Full Load Torque
% Starting Torque/Full Load Torque
Bearing DE
Bearing NDE
Ref. Std.
0.18/0.25
4
71
1420
2.5A
0.75
0.123KGM
200%
6205
6203
IS:996
0.37/0.5
4
80
1410
3.6A
0.76
0.25KGM
180%
6205
6204
IS:996
0.55/0.75
4
80
1410
3.6A
0.94
0.38KGM
190%
6205
6204
IS:996
0.75/1
4
80
1410
6.2A
0.98
0.51KGM
190%
6205
6204
IS:996
1.1/1.5
4
90L
1385
7.5A
0.98
0.77KGM
200%
6205
6205
IS:996
1.5/2
4
100L
1440
11A
0.85
1.02KGM
196%
6206
6205
IS:996
Electrical performance Figures of standard TEFC Foot, flange & Face Mounted,
Single phase at 230V, 50HZ, S1 duty, IP :55 F Class, 40 C Amd.0
Table No. - 16
Table No. - 17
LHP Energy Efficient Motors conform to Energy EfficiencyLevel I (IS : 12615)
Suitable for continuous process industries where high energysaving is essential Short payback period for replacementEnhanced motor life Less maintenance
Applications :
Machine tools, Textile, Air conditioning, Diary equipment, Packingmachinery, Material handling equipment, Geared Motors, Woodseasoning plants, Solvent Extraction plants, Edible oil factories,Cement, paper & steel plants.
Applicable Standards
IS : 4722
IS : 325 (IEC 34 - 1)
IS : 4691 (IEC 34 - 5)
IS : 4889 (IEC 34 - 2)
IS : 12615 (IEC 34-30)
IS : 12824
Range
RPM
Mounting
Frame
Protection
Insulation
Voltage
Frequency
Up to 315 kW
3000, 1500, 1000, 750 (synchronous)
Foot (B-3), Flange (B-5), Face (B-14)
and combinations
71 to 355 L
IP 55
F class
415 V, 380 V or as per requirement
50 HZ / 60 HZ or as per requirement
Specifications for rotating electrical machine
Specifications for 3 phase induction motors
Degrees of protection provided by enclosure for rotating electrical machines
Method of determination of efficiency of rotating electrical machines
Specifications for Energy Efficiency Induction Motors
Type of duty and class of rating assigned to rotating electrical machines
Performance figures of Energy Efficient Sq. Cage 2 Pole Induction Motors Conforming to IS : 12615 (IE-2)
OutputFrame Speed
Efficiency Power FactorCurrent
kW HP FL 3/4 FL 1/2 FL FL 3/4 FL 1/2 FL
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30
37
45
55
75
90
110
125
132
160
0.5
0.75
1
1.5
2
3
5
7.5
10
12.5
15
20
25
30
40
50
60
75
100
120
150
170
180
215
71
71
80
80
90S
90L
100L
132S
132S
160M
160M
160M
160L
180M
200L
200L
225M
250M
280S
280M
315S
315M
315M
315L
2800
2800
2800
2820
2820
2845
2900
2900
2920
2900
2900
2920
2900
2945
2940
2900
2930
2950
2950
2965
2965
2970
2970
2980
72.2
74.8
77.4
79.6
81.3
83.2
85.5
87
88.1
89.3
89.4
90.3
90.9
91.3
92
92.5
92.9
93.2
93.8
94.1
94.3
94.5
94.6
94.8
72.2
74.8
76.4
79.6
81.3
83.2
84.5
87
88.1
89.3
89.4
90.3
90.9
91.3
92
92.5
92.9
93.2
93.8
94.1
94.3
94.5
94.6
94.8
70
72.8
74.4
77.6
78
81.6
83
85
86.1
88.3
87.4
88.3
88.9
89.3
90
90.5
91.7
92.2
92.7
91.3
93.3
93.7
93.8
94
0.75
0.79
0.82
0.83
0.85
0.87
0.87
0.85
0.84
0.87
0.87
0.90
0.88
0.90
0.88
0.87
0.88
0.86
0.85
0.85
0.87
0.88
0.89
0.90
0.73
0.74
0.82
0.80
0.81
0.84
0.85
0.84
0.83
0.85
0.85
0.87
0.83
0.87
0.87
0.86
0.84
0.83
0.83
0.82
0.83
0.84
0.85
0.88
0.64
0.66
0.72
0.73
0.79
0.82
0.82
0.80
0.79
0.79
0.80
0.82
0.80
0.82
0.82
0.80
0.80
0.80
0.79
0.76
0.77
0.78
0.79
0.87
0.95
1.3
1.65
2.3
3
4.2
6.9
10.3
14
16.6
19.5
25.5
32
37
51.5
64
76
95
130
156
186
209
220
260
15.0 Energy Efficient Motors (IE-2)
23
Table No. - 18
Performance figures of Energy Efficient 4 Pole Sq. Cage Induction Motors Conforming to IS : 12615 (IE-2)
OutputFrame Speed
Efficiency Power FactorCurrent
kW HP FL 3/4 FL 1/2 FL FL 3/4 FL 1/2 FL
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30
37
45
55
75
90
110
125
132
160
0.5
0.75
1
1.5
2
3
5
7.5
10
12.5
15
20
25
30
40
50
60
75
100
125
150
170
180
215
71
80
80
90S
90L
100L
112M
132S
132M
160M
160M
160L
180M
180L
200L
225S
225M
250M
280S
280M
315S
315M
315M
315L
1340
1350
1385
1435
1430
1450
1445
1450
1450
1455
1460
1465
1455
1460
1450
1475
1475
1470
1480
1480
1485
1485
1485
1487
70.1
75.1
79.6
81.4
82.8
84.3
86.3
87.7
88.7
89.8
89.8
90.6
91.2
91.6
92.3
92.7
93.1
93.5
94
94.2
94.5
94.6
94.7
94.9
70.1
75.1
79.6
81.4
82.8
84.3
86.3
87.7
88.7
89.8
89.8
90.6
91.2
91.6
92.3
92.7
93.1
93.5
94
94.2
94.5
94.6
94.7
94.8
69.1
73.1
76.1
80.6
80.3
82.3
84
86
87.6
89.3
89.1
90.1
89.6
91
91.1
92.2
92.4
91.3
92.3
92.7
93.2
93.2
93.2
93.6
0.73
0.78
0.72
0.69
0.72
0.80
0.78
0.85
0.84
0.84
0.85
0.82
0.85
0.83
0.87
0.85
0.88
0.87
0.82
0.85
0.85
0.85
0.86
0.87
0.69
0.76
0.70
0.68
0.70
0.78
0.76
0.83
0.80
0.82
0.83
0.80
0.83
0.80
0.85
0.82
0.83
0.85
0.79
0.83
0.83
0.82
0.84
0.84
0.66
0.71
0.60
0.65
0.66
0.74
0.72
0.77
0.73
0.75
0.79
0.75
0.79
0.74
0.76
0.74
0.77
0.76
0.72
0.74
0.74
0.72
0.85
0.75
1
1.3
1.8
2.7
3.5
4.5
7.6
10.2
14.0
17
20
28
33
40
52
65
76
94
135
155
190
215
225
269
24
Table No. - 19
Performance figures of Energy Efficient Sq. Cage 6 Pole Induction Motors Conforming to IS : 12615 (IE-2)
OutputFrame Speed
Efficiency Power FactorCurrent
kW HP FL 3/4 FL 1/2 FL FL 3/4 FL 1/2 FL
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30
37
45
55
75
90
110
132
0.5
0.75
1
1.5
2
3
5
7.5
10
12.5
15
20
25
30
40
50
60
75
100
125
150
170
80
80
90S
90L
100L
112M
132S
132M
160M
160L
160L
180L
200L
200L
225M
250M
280S
280M
315S
315M
315M
315L
900
900
920
920
930
945
960
950
960
960
970
960
980
980
980
980
980
985
985
985
990
990
69
72.9
75.9
78.1
79.8
81.8
84.3
86
87.2
88.5
88.7
89.7
90.4
90.9
91.7
92.2
92.7
93.1
93.7
94
94.3
94.6
69
72.9
75.6
78.1
79.8
81.8
84.3
86
87.2
88.5
88.5
89.7
90.4
90.7
91.7
92.2
92.7
93.1
93.7
94
94.3
94.6
67.6
70.4
72.4
71.1
72.8
77.8
80.3
83.2
83.7
85
86.5
88.2
88.6
88.9
89.3
90.2
90.5
89.6
90.5
91.7
92.5
93.2
0.57
0.62
0.65
0.70
0.72
0.72
0.76
0.74
0.78
0.81
0.82
0.83
0.86
0.84
0.84
0.82
0.82
0.88
0.82
0.78
0.81
0.82
0.54
0.59
0.62
0.67
0.69
0.68
0.72
0.69
0.70
0.75
0.79
0.79
0.81
0.79
0.79
0.78
0.78
0.80
0.81
0.77
0.80
0.80
0.50
0.54
0.55
0.61
0.64
0.62
0.60
0.61
0.62
0.65
0.69
0.79
0.71
0.66
0.71
0.71
0.70
0.70
0.72
0.70
0.72
0.73
1.3
1.7
2.1
2.8
3.6
5.2
8
12
15.2
18
21
28
33
40
54
68
82
98
135
169
200
235
Performance figures of Energy Efficient Sq. Cage 8 Pole Induction Motors
OutputFrame Speed
Efficiency Power FactorCurrent
kW HP FL 3/4 FL 1/2 FL FL 3/4 FL 1/2 FL
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30
37
45
55
75
90
110
0.5
0.75
1
1.5
2
3
5
7.5
10
12.5
15
20
25
30
40
50
60
75
100
125
150
90S
90L
100L
100L
112M
132S
160M
160L
160L
180M
180L
200L
225S
225M
250M
280S
280M
315S
315M
315L
315L
680
700
700
710
710
710
720
720
720
730
735
735
735
730
730
735
735
735
735
730
735
66.80
71.10
73.8
76.20
78.5
80.50
83.00
85.10
86.40
87.30
88.10
89.00
89.80
90.20
91.50
91.90
92.40
92.80
93.50
93.90
94.30
66.80
71.10
73.80
76.20
78.5
80.50
83.00
85.10
86.40
87.30
88.10
89.00
89.80
90.20
91.50
91.90
92.40
92.80
93.50
93.90
94.30
66.40
70.00
72.30
75.40
75.00
77.80
82.00
84.00
85.00
86.00
87.00
87.30
88.20
88.50
88.70
89.00
89.20
89.30
89.30
90.00
90.60
0.55
0.54
0.59
0.65
0.70
0.66
0.80
0.82
0.72
0.73
0.75
0.71
0.82
0.79
0.79
0.78
0.78
0.82
0.80
0.81
0.81
0.53
0.52
0.55
0.62
0.69
0.60
0.72
0.74
0.66
0.66
0.68
0.66
0.76
0.76
0.76
0.75
0.75
0.80
0.78
0.78
0.78
0.48
0.48
0.50
0.58
0.65
0.55
0.60
0.60
0.60
0.60
0.58
0.58
0.66
0.68
0.66
0.68
0.66
0.70
0.68
0.68
0.68
1.4
2.0
2.4
3.1
3.8
5.8
7.8
11
16.7
20.3
23
33
35
43
58
71
87
102
138
165
200
Table No. - 20
Table No. - 21
25
71
80
90S
90L
100L
112M
132S
132M
132M(N)
160M
160L
180M/L
200L
2255/M
250M
280S/M
315L
130
165
165
165
215
215
265
265
265
300
300
300
350
400
500
500
600
110
130
130
130
180
180
230
230
230
250
250
250
300
350
450
450
550
160
200
200
200
250
250
300
300
300
350
350
350
400
450
550
550
660
10X4
12X4
12X4
12X4
15X4
15X4
15X4
15X4
15X4
19X4
19X4
19X4
19X4
19X8
19X8
19X8
24X8
3.5
3.5
3.5
3.5
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
6.0
10
10
12
12
12
12
12
12
12
13
13
13
15
16
22
22
22
180
200
235
255
270
280
310
350
375
420
462
520
570
605
695
785
935
115
120
160
160
155
170
210
210
210
233
233
256
313
370
415
430
520
5
6
8
8
8
8
10
10
10
12
12
14
16
18
18
20
22
11
15.5
24
24
24
24
33
33
33
37
37
42.5
49
53
58
67.5
71
16
21.5
31
31
31
31
41
41
41
45
45
51.5
59
64
69
79.5
85
17
20
30
30
30
30
40
40
40
45
45
50
60
65
70
90
95
55
60
60
60
60
60
90
90
90
90
90
100
100
100
100
120
130
14
19
28
28
28
38
38
42
42
48
55
60
65
75
80
j6
j6
j6
j6
k6
k6
k6
k6
k6
k6
k6
k6
m6
m6
m6
m6
m
28
38
6
25
50
50
50
50
50
75
75
75
75
75
105
105
115
115
120
120
M12
16
24
24
24
24
30
30
30
30
30
30
30
40
40
40
M
M
M
M
M
M
M
M
M
M
M
M
M30
M
M
M
30
30
50
50
50
50
50
50
50
50
50
50
50
50
60
60
60
20
45
45
45
45
45
65
65
65
70
70
90
95
100
100
100
120
---
---
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
26
Cooling Tower Motors
Range
R.P.M.
Pole
Mounting
Frame
Protection
Insulation
Voltage
Frequency
Duty
Paint
Up to 270 HP (200 kw)
1500, 1000, 750
4/6/8
B5 / Shaft downward position V1
71 to 315 L
IP 55
F Class
415 V, 380 V or as per requirment
50 Hz / 60 Hz
S1
With Anti corrosive Epoxy paint
IS - 4722
IS - 325 (IEC 34 - 1)
IS - 4691 (IEC 34 - 5)
IS - 4889 (IEC 34 - 2)
IS - 2223 (IEC 72 - 1)
Applicable Standards
Specifications for rotating electricalmachine
Specifications for 3 phase inductionmachine
Degree of protection provided byenclosure for rotating electrical machines
Method of determination of efficiency ofrotating electrical machines
Dimensions of 3 phase flange mountedinduction motors
Framesize M N P S X NO. T LA LB AD F G GA L1 D2 L2 D3 L3 X OAOD1
---
---
8
8
8
8
8
8
8
8
8
8
10
10
10
10
10
B
Table No. - 22
27
16.0 Flame - Proof Motors
16.1 Salient Features
1. LHP Flame - Proof motors are suitable for GAS GROUP I. IIA, IIB and IIC applications.
2. Suitable for temperature class T6 for motors in up to 90 frame size & T4 for motors in 100 & above frame sizes.
3. Motors are designed for continuous operation in explosive or inflammable atmosphere in coal mines. Chemical,
Petrochemical Industries, fertilizers & pharmaceutical industries.
4. Flame-Proof motors comply with IS/IEC 60079-1 specifications and rating performance as per IS : 325
5. Motors are suitable for horizontal & vertical mounting as per IS : 1231 & IS : 2223 & IEC 60072-2
6. Motor frames & end shields are made of grey cast iron with sturdy design & have high strength to prevent internal
explosion due to the external inflammable gas.
7. All fasteners used are provided with shrouds around their heads to prevent from opening easily i.e. Tamper-proof and
to maintain the graphs as specified. Also they are of a high tensile material (Minimum tensile strength 400 N/min )
8. Motors terminals studs are of brass suitable for D.O.L. Strating up to 3HP (3 terminals) & above 3HP Star / Delta starting
provision is made (6 terminals). The insulating material of Terminal Studs is made up of Dough Moulding compound.
9. Motors with mining application (gas group - I) are provided with cable entries either with compound filling sealing box
or with Flameproof wiping type cable glands or with FLP Plug & Socket as required.
10. Flame-Proof compression glands suitable for armoured or unarmoured Copper or Alluminium cables can be given.
11. All motors are with top terminal box.
2
16.2 Approval / Certification
16.3 Dimensional Details
A. Flame - Proof motors carry the BIS mark (IS : 2148, IS/IEC60079- 0&1) and are tested by ERTL- Kolkata, CIMFR- Danbad
& Karandikar Test Lab., Mumbai.
B. Approval certifications of following are taken based on the test report issued by ERTL
1. Petroleum & Explosives Safety Organisation (PESO), Nagpur.
2. Directorate General of Mines Safety (DGMS), Dhanbad.
Kolkata & CIMFR, Danbad,
KLPL Mumbai.
C. CE ATEX
Please refer to Table No. 22, 23 & 24
16.4 Electrical Performance
Please refer to Table No. 25, 26, 27 & 28
16.5 Frame - wise Outpur
Please refer to Table No. 2A
16.6 Frame wise Bearing sizes
Bearing No.
DE NDE
6201 ZZ
ZZ
6205 ZZ
6206 ZZ
6306 ZZ
6308 ZZ C3
6309 ZZ C3
6310 ZZ C3
6312 ZZ C3
6313 ZZ C3
6314 C3
6318 C3
6319 C3
6203 ZZ
6204
6201 ZZ
ZZ
6205 ZZ
6206 ZZ
6206 ZZ
6208 ZZ C3/6308 ZZ C3
6309 ZZ C3/6209 ZZ C3
6310 ZZ C3
6312 ZZ C3
6313 ZZ C3
6314 C3
6415 C3
6319 C3
6203 ZZ
6204
63
L
M
1 S/M
M/L
M/L
L
S/M
M
S/M
S/M/L
71
80
90S/L
100
112
32
160
180
200
225
250
280
315
Frame
Size
17.0 Dimensions of Foot Mounted Flame-Proof Motors (B-3 Mounting) as per IS : 1231
LF-180 to LF-225 Frame
28
LF-90 to LF-160 Frame LF-71 to LF-160 Frame LF-90 to LF-315 Frame
Dimensions of Foot Mounted Flame - Proof Motor (B3 MOUNTING As per IS : 1231)
63M
M
M
(4,6&8P)
280S (2P)
280S (4,6&8P)
280M (2P)
280M (4,6&8P)
315S (2P)
315S (4,6&8P)
315M (2P)
315M (4,6&8P)
315 (2P)
315L (4,6&8P)
71
80
90S
90L
100L
112M
132S
132M
160M
160L
180M
180L
200L
225S (2P)
225S (4,6&8P)
225M (2P)
225M (4,6&8P)
250M (2P)
250M
63
71
80
90
90
100
112
132
132
160
160
180
180
200
225
225
225
225
250
250
280
280
280
280
315
315
315
315
315
315
40
45
50
56
56
63
70
89
89
108
108
121
121
133
149
149
149
149
168
168
190
190
190
190
216
216
216
216
216
216
100
112
125
140
140
160
190
216
216
254
254
279
279
318
356
356
356
356
406
406
457
457
457
457
508
508
508
508
508
508
125
140
165
180
180
208
240
265
265
314
314
340
340
390
440
440
440
440
500
500
540
540
540
540
620
620
620
620
620
620
10
10
10
12
12
13
15
16
16
18
18
25
25
25
32
32
32
32
35
35
40
40
40
40
50
50
50
50
50
50
7
7
10
10
10
12
12
12
12
15
15
15
15
19
19
19
19
19
24
24
24
24
24
24
28
28
28
28
28
28
80
90
100
100
125
140
140
140
178
210
254
241
279
305
286
286
311
311
349
349
368
368
419
419
406
406
457
457
508
508
100
115
140
170
170
188
190
240
240
314
314
340
340
380
375
375
375
375
425
425
490
490
490
490
600
600
600
600
600
600
130
145
180
192
192
217
240
272
272
316
316
358
358
381
447
447
447
447
484
484
540
540
540
540
625
625
625
625
625
625
11j6
14j6
19j6
24j6
24j6
28j6
28j6
38k6
38k6
42k6
42k6
48k6
48k6
55m6
55m6
60m6
55m6
60m6
60m6
65m6
65m6
75m6
65m6
75m6
65m6
80m6
65m6
80m6
65m6
80m6
23
30
40
50
50
60
60
80
80
110
110
110
110
110
110
140
110
140
140
140
140
140
140
140
140
170
140
170
140
170
4
5
6
8
8
8
8
10
10
12
12
14
14
16
16
18
16
18
18
18
18
20
18
20
18
22
18
22
18
22
8.5
11.0
15.5
20.0
20.0
24.0
24.0
33.0
33.0
37.0
37.0
42.5
42.5
49.0
49.0
53.0
49.0
53.0
53.0
58.0
58.0
67.5
58.0
67.5
58.0
71.0
58.0
71.0
58.0
71.0
12.5
16.0
21.5
27.0
27.0
31.0
31.0
41.0
41.0
45.0
45.0
51.5
51.5
59.0
59.0
64.0
59.0
64.0
64.0
69.0
69.0
79.5
69.0
79.5
69.0
85.0
69.0
85.0
69.0
85.0
M5
M5
M6
M8
M8
M10
M10
M12
M12
M16
M16
M16
M16
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
Frame Size H0.5
C A AB HA B BB ADMAX
E F G GA TH CG ( )NOS.METRIC XOK OAC ODAD*
MAXL
MAXL MAX
For Brake Motor
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
372
415
517
517
551
588
749
749
877
877
924
924
--
* MARKED DIMENSION IS FOR GAS GROUP IIC APPLICATION MOTOR & OTHER DIMENSIONS ARE SAME AS ABOVE.Note : Cable Gland size may be changed according to cable size as per customer requirement.
Table No. - 23
125
135
145
247
247
262
277
294
294
319
319
413
413
413
458
458
458
458
527
527
558
558
558
558
602
602
602
602
602
602
125
135
145
243
243
258
274
291
291
320
320
360
360
415
525
525
250
275
300
377
377
439
462
590
590
708
708
735
735
825
850
882
850
882
987
937
1120
1045
1120
1045
1247
1252
1247
1252
1247
1252
M20 X 1
M20 X 1
M20 X 1
M20 X 1
M20 X 1
M20 X 1
M25 X 1
M25 X 1
M25 X 1
M40 X 2
M40 X 2
M40 X 2
M40 X 2
M40 X 2
M40 X 2
M40 X 2
M40 X 2
M40 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
29
LF-250 to LF-315 Frame
18.0 Dimensions of Flange Mounted Flame-Proof Motors (B-5 Mounting) as per IS:2223
LF-180 to LF-225 Frame
30
LF-90 to LF-160 Frame LF-71 to LF-160 Frame LF-90 to LF-315 Frame
LF-63 to LF-80 Frame (IIA, IIB & IIC)
18.0 DIMENSIONS FOR FLANGE MOUNTED MOTORS (B5 MOUNTING) AS PER IS-2223
Frame Size OM0.3
ONj6
OPMIN
OS XNO.
T LA LD AD*MAX
OAC OD E F GA TH LMAX
CG ( )NOS
METRICX
FlangeNo.
G
31
ADMAX
BRAKE MOTORL MAX
* MARKED DIMENSION IS FOR GAS GROUP IIC APPLICATION MOTOR & OTHER DIMENSIONS ARE SAME AS ABOVE.Note : Cable Gland size may be changed according to cable size as per customer requirement.
Table No. - 24
63M
M
M
/L
/M
/L
/L
/M
/M
250M (2P)
250M (4,6&8P)
280S/M (2P)
280S/M/L (4,6&8P)
315S/M/L (2P)
315S/M/L (4,6&8P)
71
80
90S
100L
112M
132S
160M
180M
200L
225S (2P)
225S (4,6&8P)
F115B
F600B
F130B
F165B
F165B
F215B
F215B
F265B
F300B
F300B
F350B
F400B
F400B
F500B
F500B
F500B
F500B
F600B
115
130
165
165
215
215
265
300
300
350
400
400
500
500
500
500
600
600
95
110
130
130
180
180
230
250
250
300
350
350
450
450
450
450
550
550
140
160
200
200
250
250
300
350
350
400
450
450
550
550
550
550
660
660
10X4
19X8
19X8
19X8
19X8
24X8
24X8
10X4
12X4
12X4
15X4
15X4
15X4
19X4
19X4
19X4
19X8
19X8
3
3.5
3.5
3.5
4
4
4
5
5
5
5
5
5
5
5
5
6
6
10
10
10
10
11
11
12
13
13
16
16
16
22
22
22
22
22
22
--
19
16
21
23
27
34
35
55
52
48
48
55
55
50
50
45
45
130
145
180
192
217
240
272
316
358
381
447
447
484
484
540
625
625
625
11j6
14j6
19j6
24j6
28j6
28j6
38k6
42k6
48k6
55m6
55m6
60m6
60m6
65m6
65m6
75m6
65m6
80m6
23
30
40
50
60
60
80
110
110
110
110
140
140
140
140
140
140
170
4
5
6
8
8
8
10
12
14
16
16
18
18
18
18
20
18
22
8.5
11
15.5
20
24
24
33
37
42.5
49
49
53
53
58
58
67.5
58
71
12.5
16
21.5
27
31
31
41
45
51.5
59
59
64
64
69
69
79.5
69
85
M5
M20
M20
M20
M20
M20
M20
M5
M6
M8
M10
M10
M12
M16
M16
M20
M20
M20
--
---
---
---
---
---
---
---
---
372
415
517
551
588
749
877
924
---
125
135
145
247
262
277
294
319
413
413
458
458
527
527
558
558
602
602
125
135
145
243
258
274
291
320
360
415
525
525
250
280
305
377
439
462
590
708
735
825
850
882
987
937
1120
1045
1247
1252
M20 X 1
M20 X 1
M20 X 1
M20 X 1
M20 X 1
M25 X 1
M25 X 1
M40 X 2
M40 X 2
M40 X 2
M40 X 2
M40 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
M50 X 2
LF-250 to LF-315 Frame
19.0 Dimensions of Face Mounted Flame-Proof Motors (B-14 Mounting) as per IS : 2223
32
* MARKED DIMENSION IS FOR GAS GROUP IIC APPLICATION MOTOR & OTHER DIMENSIONS ARE SAME AS ABOVE.Note : Cable Gland size may be changed according to cable size as per customer requirement.
Table No. - 25
Frame Size ONj6
OPMIN
S T ADMAX
AD*MAX
OAC OD E F G GA LMAX
CG ( )NO.SMETRIC
X
FlangeNo.
THOM0.3
BRAKE MOTORL MAX
63M
M
M
/L
/M
71
80
90S
100L
112M
132S
F75C
F85C
F100C
F115C
F130C
F130C
F165C
75
85
100
115
130
130
165
60
70
80
95
110
110
130
90
105
120
140
160
160
200
M5
M6
M6
M8
M8
M8
M12
2.5
2.5
3
3.5
3.5
3.5
3.5
11j6
14j6
19j6
24j6
28j6
28j6
38k6
23
30
40
50
60
60
80
4
5
6
8
8
8
10
8.5
11
15.5
20
24
24
33
12.5
16
21.5
27
31
31
41
M5
M5
M6
M8
M10
M10
M12
250
280
305
375
435
460
588
--
375
420
527
550
590
745
125
135
145
247
259
274
296
130
145
180
192
217
240
272
125
135
145
243
258
274
291
M20 X 1
M20 X 1
M20 X 1
M20 X 1
M20 X 1
M25 X 1
M25 X 1
LF-90 to LF-132 Frame LF-71 to LF-132 Frame LF-90 to LF-132 Frame
Rated Output Frame
Size
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11.0
15.0
18.5
22.0
30.0
37.0
45.0
55.0
75.0
90.0
110.0
125.0
132.0
160.0
200.0
0.25
0.33
0.50
0.75
1.0
1.5
2.0
3.0
5.0
7.5
10.0
12.5
15.0
20.0
25.0
30.0
40.0
50.0
60.0
75.0
100.0
120.0
150.0
170.0
180.0
215.0
270.0
63
71
71
71
80
90S
90S
90L
100L
132S
132S
160M
160M
160L
180M
200L
200L
225M
250M
280S
280M
315S
315S
315M
315M
315L
315L
0.60
0.70
1.10
1.45
1.70
2.50
3.30
4.60
7.72
11.0
14.0
17.0
20.0
27.5
33.0
38.0
52.0
64.0
78.0
92.0
126
158
183
206
218
260
320
2730
2820
2800
2800
2840
2840
2860
2860
2880
2900
2900
2900
2900
2920
2910
2940
2940
2900
2950
2965
2965
2970
2970
2970
2970
2980
2980
0.06
0.09
0.13
0.19
0.26
0.38
0.51
0.75
1.25
1.85
2.52
3.13
3.70
5.01
6.20
7.30
9.95
12.44
14.87
18.09
24.70
29.65
36.11
41.04
43.33
52.35
65.44
400
430
490
520
600
530
580
660
600
650
650
650
650
650
680
650
620
650
550
700
700
700
700
700
700
700
700
240
220
250
230
240
200
240
240
220
200
200
210
200
220
220
230
220
200
200
210
190
190
180
180
180
180
180
310
320
320
300
320
250
300
300
300
250
250
280
300
300
300
300
300
300
300
300
270
270
270
270
270
270
270
0.0016
0.0016
0.0016
0.0021
0.0127
0.0136
0.0219
0.0246
0.038
0.159
0.185
0.219
0.30
0.35
0.39
0.64
0.87
0.98
1.05
1.8
6.63
8.18
11.55
12.7
13.89
14.3
18.87
11
12
17
18
24
45
46
48
59
103
111
122
159
177
200
250
300
--
--
--
--
--
--
--
--
--
--
kW HP
Rated
Current
Amps
Rated
Speed
RPM
Rated
Torque
kgm
Starting
Current
% of
Rated
Current
Starting
Torque
% of
Rated
Torque
Peak
Torque
% of
Rated
Torque
Approx.
Net
Weight
kg
Rotor
GD
kg m sq
Efficiency % Power Factor
Table No. - 26Electrical performance figures of Flame-Proof, TEFC, Foot, Flange and Face Mounted Three PhaseAt 415 V, 50Hz, Two Pole Induction Motor
100% 75% 50% 100% 75% 50%
33
2
64
70
66.1
69.1
72.1
75
77.2
79.7
82.7
84.7
86
87
87.6
88.7
89.3
89.9
90.7
91.2
91.7
92.1
92.7
93
93.3
93.4
93.5
93.8
94
62
68
64.1
64.4
70.1
72
76.2
77.2
80.7
84.7
86
87
85.6
85.7
86.8
89.9
89.7
90.7
91.2
91.1
92.7
93
93.3
93.4
93.3
93.8
94
56
62
58.1
60.1
65.1
69
73.2
75.7
75.7
82.2
86
83.3
83.6
83.7
84.8
86.9
87.7
89.7
88.2
90.1
91.2
91.5
91.8
91.9
92
92.3
92.5
0.68
0.71
0.71
0.76
0.85
0.80
0.81
0.83
0.86
0.84
0.88
0.87
0.87
0.85
0.87
0.89
0.88
0.89
0.91
0.90
0.89
0.85
0.89
0.92
0.90
0.91
0.92
0.65
0.65
0.65
0.72
0.79
0.74
0.78
0.79
0.83
0.83
0.83
0.85
0.82
0.81
0.85
0.85
0.86
0.88
0.90
0.89
0.85
0.81
0.83
0.88
0.86
0.89
0.87
0.54
0.55
0.59
0.67
0.73
0.72
0.72
0.69
0.76
0.75
0.74
0.79
0.76
0.77
0.77
0.79
0.80
0.84
0.89
0.85
0.77
0.77
0.75
0.80
0.78
0.87
0.88
Rated Output Frame
Size
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.7
5.5
7.5
9.3
9.3
11.0
15.0
18.5
22.0
30.0
37.0
45.0
55
75
90
110
125
132
160
180
200
0.16
0.25
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10.0
12.5
12.5
15.0
20.0
25.0
30.0
40.0
50.0
60.0
75
100
120
150
170
180
215
250
270
63
63
71
71
80
80
90S
90L
100L
100L
112M
132S
132M
132M
160M
160M
160L
180M
180L
200L
225S
225M
250M
280S
280M
315S
315M
315M
315L
315L
315L
0.40
0.65
0.70
1.00
1.40
1.80
2.50
3.40
4.80
6.40
7.70
11.0
14.5
20.0
18.5
22.0
28.5
34.0
40.0
54.0
67.0
79.0
96
131
156
191
215
227
271
314
339
1325
1340
1360
1390
1420
1410
1400
1410
1430
1410
1440
1440
1450
1450
1450
1460
1460
1460
1460
1465
1470
1470
1475
1480
1480
1485
1485
1485
1485
1485
1485
0.09
0.13
0.18
0.26
0.38
0.52
0.77
1.04
1.50
2.07
2.51
3.72
5.04
6.25
6.25
7.45
10.02
12.35
14.69
19.97
24.54
29.85
36.36
49.41
59.29
72.08
81.91
86.49
105.05
118.34
131.31
300
310
400
450
480
450
570
560
590
590
580
630
650
650
620
600
600
600
600
600
600
600
650
650
650
650
650
650
650
650
650
200
210
200
200
200
200
200
190
200
200
200
200
200
190
200
200
250
250
250
250
230
230
250
250
250
225
225
225
250
240
250
280
280
260
260
250
240
260
240
250
250
250
260
250
280
250
250
270
270
270
270
280
280
280
280
280
255
255
255
280
270
280
0.0035
0.0035
0.0035
0.0035
0.0130
0.0140
0.059
0.055
0.045
0.054
0.084
0.170
0.20
0.22
0.38
0.42
0.53
0.87
1.06
1.42
1.60
1.85
3.20
7.21
8.25
11.62
12.8
13.98
27.88
29.30
30.74
11
12
18
20
24
25
44
46
57
62
77
108
115
125
148
155
174
250
260
325
460
480
570
750
800
--
--
--
--
--
--
kW HP
Rated
Current
Amps
Rated
Speed
RPM
Rated
Torque
kgm
Starting
Current
% of
Rated
Current
Starting
% of
Rated
Torque
Torque
Peak
Torque
% of
Rated
Torque
Approx.
Net
Weight
kg
Rotor
GD
kg m sq
Efficiency % Power Factor
Table No. - 27Electrical performance figures of Flame-Proof, TEFC, Foot, Flange and Face Mounted Three PhaseAt 415 V, 50Hz, Four Pole Induction Motor
100% 75% 50% 100% 75% 50%
34
2
60
63
68
65.1
69.1
72.1
75
77.2
79.7
81.5
82.7
84.7
86
87.3
88.3
87.6
88.7
89.3
89.9
90.7
91.2
91.7
92.1
92.7
93
93.3
93.4
93.5
93.8
94
94
50
52
60
59.1
65.1
70.1
69
74.2
77.7
79.5
80.7
83.7
85
86.3
87.3
85.6
87.7
87.3
88.9
89.7
90.2
90.7
91.1
91.2
91.5
90.8
90.9
92.5
92.5
92.7
92.5
0.74
0.65
0.73
0.79
0.79
0.80
0.81
0.79
0.80
0.80
0.80
0.82
0.84
0.74
0.79
0.79
0.81
0.84
0.85
0.85
0.85
0.87
0.86
0.85
0.85
0.84
0.86
0.87
0.87
0.85
0.87
0.70
0.60
0.65
0.74
0.73
0.76
0.73
0.77
0.79
0.80
0.80
0.80
0.82
0.71
0.78
0.79
0.81
0.77
0.82
0.83
0.84
0.86
0.85
0.83
0.83
0.82
0.84
0.85
0.83
0.81
0.82
0.54
0.50
0.55
0.60
0.57
0.67
0.61
0.59
0.66
0.70
0.65
0.67
0.65
0.64
0.69
0.73
0.74
0.60
0.78
0.78
0.78
0.79
0.78
0.81
0.80
0.80
0.82
0.83
0.75
0.73
0.75
54
56
68
64.1
68.1
72.1
75
77.2
79.7
81.5
82.7
84.7
86
87.3
88.2
86.6
87.7
88.3
89.9
90.7
91.2
90.7
92.1
92.2
92.5
93.3
93.4
93
93.5
94
94
Rated Output Frame
Size
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11.0
15.0
18.5
22.0
30.0
37
45
55
75
90
110
132
160
0.25
0.33
0.50
0.75
1.0
1.5
2.0
3.0
5.0
7.5
10.0
12.5
15.0
20.0
25.0
30.0
40.0
50
60
75
100
120
150
180
215
71
71
80
80
90S
90L
100L
112M
132S
132M
160M
160L
160L
180L
200L
200L
225M
250M
280S
280M
315S
315M
315M
315L
315L
0.70
1.00
1.40
1.80
2.10
3.00
3.70
5.20
8.00
12.0
15.5
19.0
21.0
28.0
34.0
41.0
55.0
67
80
97
131
157
191
229
276
900
890
900
900
950
940
930
945
960
950
960
960
970
960
980
980
980
980
980
980
985
985
985
985
985
0.27
0.36
0.40
0.60
0.77
1.14
1.57
2.27
3.76
5.64
7.62
9.45
11.06
15.23
18.41
21.89
29.85
36.81
44.77
54.72
74.62
98.09
108.88
130.66
157.58
370
340
320
320
400
400
400
400
450
540
600
650
650
650
600
620
600
600
600
650
650
650
650
650
650
190
190
190
190
200
200
190
190
190
230
200
220
220
230
230
230
210
210
230
200
225
225
225
230
210
240
240
250
260
280
280
290
250
250
280
250
250
300
300
300
280
250
250
260
230
255
255
255
280
260
0.0044
0.0044
0.0123
0.0146
0.028
0.032
0.048
0.098
0.21
0.25
0.56
0.71
0.78
1.24
1.66
1.79
2.40
3.60
8.01
9.89
14.12
17.0
18.98
29.94
29.94
18
20
24
25
46
48
56
79
107
115
158
173
183
310
--
--
--
--
--
--
--
--
--
--
--
kW HP
Rated
Current
Amps
Rated
Speed
RPM
Rated
Torque
kgm
Starting
Current
% of
Rated
Current
Starting
% of
Rated
Torque
Torque
Peak
Torque
% of
Rated
Torque
Approx.
Net
Weight
kg
Rotor
GD
kg m sq
Efficiency % Power Factor
Table No. - 28Electrical performance figures of Flame-Proof, TEFC, Foot, Flange and Face Mounted Three PhaseAt 415 V, 50Hz, Six Pole Induction Motor
100% 75% 50% 100% 75% 50%
35
2
60
60
63
67
70
72.9
75.2
77.7
80.9
83.1
84.7
87
86.4
87.7
88.6
89.2
90.2
90.8
91.4
91.9
92.6
92.9
93.3
93.5
94.5
50
50
62
63
89
66.9
66.2
76.7
79.9
82.1
83.7
86
85.7
86.7
87.6
88.2
89.2
89.3
89.4
90.9
91.1
91.7
92.3
92.5
93.5
0.65
0.60
0.58
0.63
0.70
0.70
0.75
0.74
0.79
0.76
0.79
0.78
0.84
0.84
0.84
0.82
0.84
0.84
0.85
0.85
0.86
0.85
0.86
0.87
0.85
0.58
0.58
0.55
0.58
0.64
0.60
0.67
0.68
0.75
0.76
0.73
0.74
0.75
0.81
0.79
0.78
0.80
0.80
0.82
0.81
0.82
0.81
0.82
0.83
0.81
0.48
0.52
0.51
0.54
0.57
0.52
0.59
0.62
0.69
0.72
0.64
0.62
0.62
0.71
0.73
0.72
0.79
0.74
0.73
0.73
0.74
0.73
0.70
0.75
0.73
56
58
63
66
69
68.9
72.2
77.7
80.9
83.1
84.7
87
86.4
87.7
88.6
89.2
90.2
90.3
91.4
91.4
92.1
92.4
93.3
93.5
94.5
Rated Output Frame
Size
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.7
3.7
5.5
7.5
11.0
15.0
18.5
22.0
30.0
37.0
45.0
55.0
75.0
90.0
110.0
132.0
0.25
0.33
0.50
0.75
1.0
1.5
2.0
3.0
5.0
5.0
7.5
10.0
15.0
20.0
25.0
30.0
40.0
50.0
60.0
75.0
100.0
120.0
150.0
180.0
80
80
90S
90L
100L
100L
112M
132S
132M
160M
160M
160L
180M
200L
225S
225M
250M
280S
280M
315S
315M
315L
315L
315L
1.00
1.20
1.40
2.10
2.50
3.30
4.00
5.40
10.00
8.20
12.50
16.00
23.00
32.00
37.00
43.00
57.00
75.00
91.00
106.00
144.00
171.00
209.00
250.00
616
680
680
700
700
710
710
710
720
720
720
720
735
735
735
735
735
735
740
740
740
740
740
740
0.27
0.36
0.53
0.77
1.04
1.51
2.06
3.02
5.01
5.01
7.45
10.16
14.59
19.90
24.5
29.18
39.80
49.08
59.29
72.47
98.82
118.58
144.93
173.92
200
250
300
400
400
400
400
450
500
500
500
500
500
500
500
500
500
500
500
600
600
600
600
600
180
180
170
190
190
190
190
200
200
200
200
210
210
210
200
200
200
210
210
200
200
250
250
250
240
250
250
250
250
250
250
260
260
260
240
280
290
290
260
260
260
240
240
230
230
280
280
280
49
55
61
65
71
73
77
81
81
83
86
87
89
89
89
89
91
91.5
92
92.5
93
94
94
94.5
0.50
0.52
0.63
0.63
0.65
0.68
0.69
0.70
0.66
0.75
0.73
0.74
0.77
0.76
0.79
0.80
0.80
0.75
0.75
0.78
0.78
0.78
0.78
0.78
0.47
0.50
0.54
0.55
0.62
0.62
0.62
0.68
0.62
0.70
0.70
0.70
0.72
0.72
0.78
0.78
0.78
0.71
0.71
0.74
0.74
0.74
0.74
0.74
0.42
0.44
0.50
0.50
0.54
0.54
0.54
0.60
0.56
0.64
0.62
0.63
0.68
0.67
0.74
0.74
0.74
0.63
0.63
0.66
0.66
0.66
0.66
0.66
0.0143
0.0143
0.0283
0.0322
0.049
0.058
0.093
0.20
0.28
0.50
0.58
0.70
1.51
1.93
2.30
2.60
4.40
8.01
9.89
14.12
18.98
29.94
29.94
33.28
25
26
45
48
56
60
77
110
120
146
155
165
180
265
300
325
400
600
630
1300
1450
1600
1700
1850
kW HP
Rated
Current
Amps
Rated
Speed
RPM
Rated
Torque
kgm
Starting
Current
% of
Rated
Current
Starting
% of
Rated
Torque
Torque
Peak
Torque
% of
Rated
Torque
Approx.
Net
Weight
kg
Rotor
GD
kg m sq
Efficiency % Power Factor
Table No. - 29Electrical performance figures of Flame-Proof, TEFC, Foot, Flange and Face Mounted Three PhaseAt 415 V, 50Hz, Eight Pole Induction Motor
47
51
59
63
69
73
75
80
79
82
85
85
88
88
88
88
90
91.5
92
92.5
93
94
94
94.5
43
47
59
61
64
71
71
78
77
81
83
83
86
87
87
87
89
89.5
90.5
91
91.5
92
92.5
92.5
100% 75% 50% 100% 75% 50%
36
2
Roller Table Motors
LHP Roller Table Motors are designed taking into consideration theexperience of users in steel plants over the years.
Applications
In steel plants for conveying steel billets forprocessing through roller mills
Suitable for Geared Motors operating with VVVF source
Applicable Standards
Roller Table Motors
IPSS - 1-03-007 Inter plant standard for steel industries
IPSS - 325 (IEC 34-1) Specifications for 3 phase induction motors
IPSS -4691 (IEC 34-5)Degrees of protection provided by enclosure forrotating electrical machinery
Range
Pole
Mounting
Frame
Voltage
Frequency
Stalled rotor
withstand time
Insulation
Duty
Frame with circular fines disign
Torque : 1Kgm - 35.5kgm
4/6/8
Standard / Special as per IPSS
specifications
Upto 355L
415V AC or (upto 660V)
50Hz
Up to 15 minutes max or as per
customer requirement
H Class
S3, S4, S1,S5,S6 & S7
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Construction : Motor Frame, End
Shields, Flanges, Bearing cover
Winding
Rotor
Output Rating / Poles
Eye bolts
Shaft
Shaft extension
Terminal box Assembly
Cable Entry
Std. Entry with
3/4" BSC for 132 fr.
Dimensions
Bearings
Mounting & Mounting
Position
Fan
Fan cover
Supply voltage & frequency
Performance
Duty
Method of Starting
Method of Cooling
Design and constructional features :
Parameters Standard Features Optional Features
The components fabricated from steel
with necessary re-inforcement
H class but temp. rise will be limited to B, F class
with special insulating varnish/ impregnating
resign with tropical & fungicidal treatment
Copper die cast of brazed rotors
-
S.S. / Alloy steel
Shaft with other material like S.S. / Alloy steel etc.
Motors with both side extension / special extension.
Fabricated from steel.
positions like LH. & RH. & Top.
-
T. studs & its accessories in special material
T. blocks in porcelain or special insulating material.
Other entries in metric & PG type threads with other
entry sizes/nos. The clearance & creepage distances
Special dimensions with special flanges/frames.
Motors with other type of bearings (angular contact
ball bearings, cylindrical/taper roller bearing etc.)
Motors with online greasing arrangement.
Motors with special foot/flange for horizontal
& vertical mounting
Made from fabricated steel, S.S.
Other on request upto 660V
Special requirement if any.
Other duties - S1 to S9
Totally Enclosed Naturally Cooled (TENC) / Air Over
Motors (AOM) or forced cooled with auxiliary blower
Non-Sparking Motors (Ex 'nA')
37
The components of these motors are made of cast Iron Aluminumhaving
sufficient strength and dimensional stability.
Motors are designed with F class insulation & temp. rise is limited to the
values specified in IS/IEC 600 79-15 Windings are impregnated with
insulating varnish & baked. Overhang of the winding is treated with epoxy
gel coat to give mechanical, electrical and thermal stability and strength
Rotors are made of die cast Aluminum with squirrel cage construction
Please refer to table - 1
Eye bolts are made of forged steel
Shafts are made of carbon steel (40C8 grade IS 2073 / EN-8 BS : 970)
Motors are supplied with standard extension on drive end as per
IS : 1231 / IS : 2223 (Pls refer table 3,4,5)
Terminal box & cover are made of cast iron Aluminum
T. Box can be rotated through 360 in steps of 90 .
Clearance & creepage distances are maintained as per IS / IEC : 60079-15
& IS : 6381. Terminal studs & its accessories are made from brass / s.s. and
are nicket plated. Terminal blocks are made from DMC / Epoxy or HD
Compressed type-II of IS : 3513 Part-I or P-120 grade Bakelite & are
non-hygroscopic. Cable lugs of terminal connections are anti-loosening
& are non-loosening & anti-vibration type.
Standard entry with 3/4" B.S.C.01 no up to 1 frame
Standard entry with 1" B.S.C. -02 no 160 to 180 frame
Mounting dimensions of motor frame, flangers & shafts are as per
IS : 1231 / IS : 2223
Motors are designed with single row double shielded deep groove ball
bearings and are pre-greased with high temp. grease for life up to 225
frame. For 250 to 315 frame bearing are provided with greasing
arrangement Bearing life is 40,000 Hrs.
Motors are offered with foot mounting, flange mounting with B type flange
& flange mounting with C type flange mounting. Motors are suitable for
horizontal (B3, B5, B6, B7, B8) & vertical (V1, V3, V5, V6, V18, V19) mounting
position as per IS : 2253
Fan is made from
Fan cover is made of .S. sheet metal pressed / welded.
Motors are designed for 415V 10% with 50HZ 5% supply
Performance of motors as per I : 325
S1 (continuous)
Motor up to 5 HP are suitable to DOL starting Motors above
5 HP are suitable for Star Delta connection
Standard motors are Totally Enclosed Fan Cooled (TEFC)
32
Standard entry with 2" B.S.C. -01 no 200 to 355 frame
(Pl. Refer Table 3,4,5)
Cast iron / M. S.
M
S
No.
20
21
22
23
24
25
26
27
Surface Temp.
Noise & Vibration
Protection
Environment Condition
Space heater
Hardware
Drain hole
Paint
Parameters Standard Features Optional Features
The surface temp. is limited to Lan T3 Temp clan (200 C)
(Temp. calss T3) under normal operating condition to prevent
thermal ignition in surrounding explosive atmosphere.
Motors are with noise level maintained as per IS : 12065 & vibration
level of normal class as per IS : 12075.
IP : 55 for Motor enclosure & T. Box
Amb. Temp.: 50 C,
Relative Humidity : 95% max.
On request.
All hardware (fasteners0 are Zinc plated to prevent
from corrosion.
Drain hole with plug screw on end shields to remove condensate
water for motor 180 & above frames.
Motors are painted with one coat of primer followed
by two coasts of anti-corrosive paint.
Other temp. class on request.
Motors with low noise level & precision
class of vibration.
Superior protection as per IS : 4691.
Any special environment condition.
Space heater & Thermistor provided with
separate T Box for connection
Special hardware with special
Material, grade, type & plating.
-
Motors with special paint & shade.
Output Range
Poles
Voltage
Frequency
Phase
Insulation Class
Mounting
Ambient Temp.
Protection
Duty
Method of cooling
Mounting position
Dimensions
Performance
Reference Standards
Certification
Application
Standard Specifications
Specifications
0.12/315 kW (0.16/425 HP)
2,4,6 & 8
415 V 10%
50 Hz 5%
3
F
Foot, Flange & face mounted
40 C
IP-55
S1
TEFC
B3, B5, B14, B34, B35
V1, V3, V5, V6, V18 & V19
As per IS: 1231/IS-2223
As per IS-325, IS/IEC 60079-15
IS/IEC 60079-15
Tested by
Approved by , Nagpur
Suitable for zone-2
classification of
hazardous area
(Ex 'nA')
ERTL Kolkata
PESO
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
1
2
3
Non-sparking (Type-'nA')
Pole-wise frame sizes
Output(kW/HP)
2 Pole 4 Pole 6 Pole 8 Pole 2 Pole 4 Pole 6 Pole 8 Pole
0.12/0.16
0.18/0.25
0.25/0.33
0.37/0.50
0.55/0.75
0.75/1.00
1.10/1.50
1.50/2.00
2.20/3.00
3.70/5.0
5.50/7.50
7.50/10.00
9.30/12.50
11.00/15.00
15.00/20.00
18.50/25.00
22 / 30
30 / 40
37 / 50
45 / 60
55 / 75
75 / 100
90 /120
110 / 150
125 / 170
132 / 180
160 / 215
180 / 250
200 / 270
235/300
250/335
315/425
71
71
71
71
71
80
80
90S
90L
100L
132S
132S
132M
160M
160M
160L
180L
200L
225S
250M
250M
280S
280M
315S
315M
315M
315L
315L
315L
71
71
71
71
80
80
90S
90L
100L
112M
132S
132M
160M
160M
160L
180M
180L
200L
225S
225M
250M
280S
280M
315S
315M
315M
315L
315L
315L
71
71
71
80
80
90S
90L
100L
112M
132S
132M
160M
160L
160L
200L
200L
225M
225M
250M
280S
280M
315S
315M
315M
-
315L
315L
-
-
-
80
80
90S
90L
100L
100L
112M
132S
160M
160M
160L
180M
180L
200L
225S
225M
250M
280S
280M
315S
315S
315M
315M
-
315L
315L
-
-
63
63
63
132S
160M
50
355L
355L
355L
71
71
80
80
90S
90L
100L
132S
132M
160M
160L
180L
200L
200L
225M
2 M
280S
280M
315S
315M
315M
315L
315L
315L
63
63
132S
160M
355L
355L
355L
71
71
80
80
90S
90L
100L
112M
132M
160M
160L
180M
180L
200L
225S
225M
250M
280S
280M
315S
315M
315M
315L
315L
315L
71
71
71
80
80
90S
90L
100L
112M
132M
160M
L
160L
200L
225M
225M
250M
280S
280M
315S
315M
315M
-
315L
315L
-
132S
160
200L
355L
355L
355L
-
71
132S
355L
355L
-
-
80
80
90S
90L
100L
100L
112M
160M
160M
160L
180M
180L
200L
225S
225M
250M
280S
280M
315S
315S
315M
315M
-
315L
315L
-
38
20.00 Tolerance on Performance Values & Dimensions
The electrical performance data (for Standard, Crane & Flame-Pfoof motors) namely current, power factor, efficiency, full load speedand torque at full load, starting torque & pull out torque are given in the table, These values are subjected to the following tolerancesBeside these, values are given for information & guidance.
Efficiency (n) :
a) By summation of losses :
Motors up to 50 kW
Motors above 50 kW
b) By input-Output test
Total losses applicable to motors above 50 kW*
Power factor (Cos O)
Slip at full load and at working temperature
Breakaway starting current of squirrel cage
Induction motors with short-circuit rotor and
with any specified starting apparatus.
Breakaway torque
Pull out toque
Flame size H > 250
< 355
Diameter O of shaft exiension :
(i) 11 to 28 mm
(ii) 32 to 48 mm
(iii) 55 mm and over
Diameter N of Flange spigot :
Key with
Width of drive shaft keyway (normal keying)
Key depth :
(i) Square section
(ii) Rectangular section
i.
ii.
iii.
iv.
v.
vi.
vii.
Electrical Parameters
Mechanical Parameters
-15 percent of (1-n)
-10 percent of (1-n)
-15 percent of (1-n)
+ 10 percent of the total losses
-1/6 of (1 Cos O) Min. 0.02 and Max. 0.07
+ 20 percent of the guaranteed slip
+ 20 percent of the guaranteed starting current (no negative tolerance)
- 15 percent to + 25 percent of the guaranteed torque (+ 25 percent
may be exceeded by agreement)
-10 percent of the guaranteed torque except that after allowing for this
tolerance, the torque shall be not less than 1.6 or 1.5 times the rated torque
0, -0.5 mm
0, -1 mm
j6
k6
m6
j6 up to F 740 B
h9
N9
h9
h1 1
Dimensions Talerance
39
0
10
18
30
50
80
F65
F75
F85
F100
0115
F130
F165
F215
F265
F300
F350
F400
F500
F600
10
18
30
50
80
120
50
60
70
80
95
110
130
180
230
250
300
350
450
550
0.030
0.035
0.040
0.050
0.060
0.070
0.080
0.080
0.080
0.080
0.080
0.100
0.100
0.100
0.100
0.125
0.125
0.125
0.125
0.160
0.015
0.018
0.021
0.025
0.030
0.035
0.040
0.040
0.040
0.040
0.040
0.050
0.050
0.050
0.050
0.063
0.063
0.063
0.063
0.080
Diameter of shaft extension run out of motoers
Over Up to Normal Precision Class
Flange No. Spigot Dia. Normal Class Precision Class
Concentricity of spigot diameter and perpendicularily of mounting surface of flange with respect to shaft
40
Table No. - 30
63
71
80
90
100
112
132
160
180
200225
250
280
315
355
63
71
80
90
100
112
132
160
180
80
90
100
112
132
160
180
200
225
250
280
315
Thermocole (EPS)
Thermocole (EPS)
Thermocole (EPS)
Thermocole (EPS)
Thermocole (EPS)
Thermocole (EPS)
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Corrugated
Corrugated
Corrugated
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
Wooden Box
8.5
8.5
18
28
40
50
80
133
174
280
325
770
1500
2050
13
17
25
42
50
60
100
150
200
35
45
60
80
100
150
225
250
290
350
950
1600
10
12.5
20
30
58
68
106
173
214
330
385
1150
1950
2500
15
19
40
60
70
90
125
200
250
45
60
80
100
125
200
275
300
350
400
1200
2000
245 x 180 x 195
280 x 195 x 220
230 x 250 x 250
425 x 250 x 305
480 x 320 x 295
650 x 395 x 480
700 x 495 x 495
875 x 650 x 610
875 x 650 x 610
940 x 790 x 790
1170 x 920 x 920
1320 x 970 x 970
1475 x 965 x 1095
2020 x 1225 x 1310
425 x 250 x 305
425 x 250 x 305
425 x 250 x 305
570 x 355 x 420
650 x 395 x 480
700 x 495 x 585
800 x 520 x 535
875 x 650 x 610
940 x 790 x 790
580 x 355 x 420
650 x 395 x 480
650 x 395 x 480
700 x 495 x 585
700 x 495 x 585
940 x 790 x 790
940 x 790 x 790
940 x 790 x 790
1070 x 940 x 790
1475 x 965 x 1095
1475 x 965 x 1095
1475 x 965 x 1095
For Three Phase Standard Induction Motors
Fame Size Type of Packing Net Weight in kg (Max.) Gross Weight in kg (Max.) L x B x HT. in mm (Max.)
Brake Motors
Flame - Proof Motors
41
Shipping Specifications
Table No. - 31
Certain information is necessary to offer the right type of motor for desired application. The necessary information to be funishedalong with Enquiry / Purchase Order is as follows.
Information required along with Purchase Order / Enquiry
Standard / Crane and Hoist Duty Motors
Name of Customer :
Address :
Output / kW :
Speed :
Frame Size :
Construction :
Application :
Type of duty & Frequency :
Method of Cooling :
Supply Voltage & Frequency :
Amb. Temp. & Type of protection required :
No. of starts / stops per hour with duty & CDF :
Load Torque :
Duty cycle if other than those given in diagram :
Any specified requirement - related to
Amb. Temp., Starting Current & Torque :
Additional information for Brake Motors
Brake Type :
Brake Size :
Coil Operating Voltage :
Hub Bore :
Whether rectifier is required :
(All other information similar to standard motors):
Gas group I, IIA or IIB :
Application for which motors are used :
Classification of Hazardous area :
Load GD2 :
Cable Arrangements :
Compression Gland Size / Type :
No. of cable entries :
Whether sealing box is required :
(All other relevant information similar to standard motors) :
Additional information for Flame-Proof Motors / Increased Safety / Non-Sparking motors
01.
02.
03.
04.
05.
06.
07.
08.
09
10.
11.
12.
13.
14.
15.
01.
02.
03.
04.
05.
01.
02.
03.
04.
05.
Note : You are requested to fill in a photo-copy of the enquiry form and send it to us.