Titanium bases, Scan abutments and Scanbodies for CAD/CAM TITANIUM BASE The Titanium bases for CAD/CAM are used as an adhesive base for the manufacture of zirconium oxide mesostructures on gmi implants. They allow performing cement and screw retained single restorations and cemented bridges. The Scanbodies are used to capture the position and the inclination as well as the orientation of the indexing system of the replicas in the working model. Using the dental scanner, the Scanbody is optically recorded and the acquired digital information is used for the manufacture of the customized abutments on the Titanium base. Features Features · Compatible with Exocad CAD/CAM system. · Customized emergency profile for optimal anatomical shape. · Allow supragingival abutment-crown transitions for aesthetic results. · Available for gmi frontier and avantgard systems. · Clinic screw included. · Single use. · Same scanbody for all systems. · Allows scanning without the use of spray or powders. · Single use. · Exclusive use in laboratory. · Optimized scan geometry for better accuracy. · Allow increasing the height of the scanbody to facilitate scanning process. · Reusable up to 50 uses. · Exclusive use in laboratory. Greater surface area for better adhesion of the mesostructure Non-rotary system for mesostructure Connection avantgard frontier SCAN ABUTMENT SCANBODY Technical data Scan geometry Orientation mark Titanium base - frontier (mm) Reference L h h1 Ø Shoulder Connection Platform KDM0F3615 7,10 0,65 4,70 4,30 Non-rotary RP KDM0F3616 6,60 0,65 4,70 4,30 Rotary KDM0F3617 7,10 0,65 4,70 5,30 Non-rotary WP KDM0F3618 6,50 0,65 4,70 5,30 Rotary Titanium base - avantgard (mm) KDM0F4021 9,80 1,50 4,70 4,30 Non-rotary RP KDM0F4022 9,80 1,50 4,70 5,30 Non-rotary WP RP/WP Ø Shoulder h1 L h 2,45 mm Scan abutment - frontier (mm) Reference L h Ø Shoulder Platform KDI0F3601 11,70 5,30 4,30 RP KDI0F3602 11,70 5,30 5,30 WP Scan abutment - avantgard (mm) KDI0F4001 14,40 6,30 4,30 RP KDI0F4002 14,40 6,30 4,30 WP 2,45 mm RP/WP Ø Shoulder h L Ø Shoulder h1 L h RP/WP frontier avantgard Ø Shoulder h1 h L RP/WP 2,45 mm Ø Shoulder L h RP/WP RP/WP RP/WP Imp. level Imp. level Imp. level Imp. level Imp. level avantgard frontier

Upload: vuongtram

Post on 29-Oct-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

Titanium bases, Scan abutments and Scanbodies for CAD/CAM

TITANIUM BASEThe Titanium bases for CAD/CAM are used as an adhesive base for the manufacture of zirconium oxide mesostructures on gmi implants. They allow performing cement and screw retained single restorations and cemented bridges.

The Scanbodies are used to capture the position and the inclination as well as the orientation of the indexing system of the replicas in the working model. Using the dental scanner, the Scanbody is optically recorded and the acquired digital information is used for the manufacture of the customized abutments on the Titanium base.

Features

Features

· Compatible with Exocad CAD/CAM system.· Customized emergency profile for optimal anatomical shape.· Allow supragingival abutment-crown transitions for aesthetic results.· Available for gmi frontier and avantgard systems.· Clinic screw included.· Single use.

· Same scanbody for all systems.· Allows scanning without the use of spray or powders.· Single use.· Exclusive use in laboratory.· Optimized scan geometry for better accuracy.

· Allow increasing the height of the scanbody to facilitate scanning process.· Reusable up to 50 uses. · Exclusive use in laboratory.

Greater surface area for better adhesion of the mesostructure

Non-rotary system for mesostructure

Connection

avantgard

frontier

SCAN ABUTMENT

SCANBODY

Technical data

Scan geometry

Orientation mark

Titanium base - frontier (mm)Reference L h h1 Ø Shoulder Connection Platform

KDM0F3615 7,10 0,65 4,70 4,30 Non-rotaryRP

KDM0F3616 6,60 0,65 4,70 4,30 Rotary KDM0F3617 7,10 0,65 4,70 5,30 Non-rotary

WPKDM0F3618 6,50 0,65 4,70 5,30 Rotary

Titanium base - avantgard (mm)KDM0F4021 9,80 1,50 4,70 4,30 Non-rotary RPKDM0F4022 9,80 1,50 4,70 5,30 Non-rotary WP

RP/WP

Ø Shoulder

h1

L

h

2,45mm

Scan abutment - frontier (mm)Reference L h Ø Shoulder PlatformKDI0F3601 11,70 5,30 4,30 RPKDI0F3602 11,70 5,30 5,30 WP

Scan abutment - avantgard (mm)KDI0F4001 14,40 6,30 4,30 RPKDI0F4002 14,40 6,30 4,30 WP

2,45mmRP/WP

Ø Shoulder

hL

Ø Shoulder

h1

Lh

RP/WP

frontier avantgard

Ø Shoulder

h1

h

L

RP/WP2,45mm

Ø Shoulder

Lh

RP/WP

RP/WP

RP/WP

Imp. level Imp. levelImp. level

Imp. level Imp. level

avantgard

frontier

1 2 3

4 5 6

7 8 9

Create the model using conventional laboratory procedures.

Verify the scanbody is properly seated on the titanium base.

Insert the scanbody on the titanium base ensu-ring the external reference mark of scanbody is properly aligned with titanium base indexing system.

Scan the model, design and manufacture the mesostructure following the instructions of the CAD/CAM system provider.

Cement the customized abutment to titanium base. gmi recommends using PANAVIA F2.0 ma-nufactured by Kurakay. The cement must be pre-pared and mixed according to the manufacturer’s instructions. Remove any excess of cement.

Finish the process according to cement or screw retained restoration.

Placement of final crown.

Attach the titanium base to replica ensuring the indexing system is oriented to vestibular.

Firmly tighten the screw with HEX-1,20 mm wrench (REF. KYL0F0128/0129). Verify the base and replica assembly is properly seated.

✓✓