thermal control of thermal control of insects …...pal 8, tier 1, ctr pal 8, tier 3, ctr pal 8,...

39
THERMAL CONTROL OF INSECTS Brian C. Zeichner U. S. Army Center for Health Promotion and Peventive Medicine Thermal Control of Cockroaches, Snails, and Commodity/Lumber Pests Brian C. Zeichner Alfred Lynn Hoch, Zia Mehr, Daniel Topp, Donald Wood, Christina Hutchinson

Upload: others

Post on 04-Oct-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

THERMAL CONTROL OF INSECTS

Brian C. Zeichner

Alfred L. Hoch

U. S. Army Center for Health Promotion andPeventive Medicine

Thermal Control ofCockroaches, Snails, and Commodity/Lumber Pests

Brian C. Zeichner

Alfred Lynn Hoch, Zia Mehr,Daniel Topp, Donald Wood,

Christina Hutchinson

Page 2: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 3: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Facility Preparation

• Shut off all equipment• Remove

– Perishables, Spices, Bread, Fruit– Compressed gas cylinders– Flamables– Computers, TVs

• Applied Gentrol, insect growth regulator

Page 4: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Clear the floor

Page 5: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Prevent

Escapes

Page 6: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

PreventDamage

Page 7: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

SPRINKLER HEAD: TEMPERATURES INSIDE AND OUTSIDE OF INSULATOR

0 60 120 180 240 300 360

TIME (MINUTES)

70

80

90

100

110

120

130

140

TEM

PE

RA

T UR

E (

F)

OUTSIDE

INSIDE

0

Page 8: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Corral

Heat

Page 9: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

SetupHeaters

Page 10: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

VARIATION OF CEILINGTEMPERATURES

T+120 T+180 T+240115

120

125

130

135

140

145

150

155

160

165

170

TIME (MINUTES)

0TE

MP

ER

ATU

RE

( F

)

52

68

77

TEM

PE

RA

TUR

E (

C)

0

57

62

Page 11: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 12: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 13: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Prevent 4 –6 HoursDead Cockroaches

Page 14: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Vacuum the Living

Page 15: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 16: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 17: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 18: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 19: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

SHOULD METHOD BE OFFERED TO OTHER FACILITIES

YES NO NOT SURE0

5

10

15

20

N

UM

BE

R

RE

SP

ON

DIN

G

Page 20: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Process Detailedhttp://chppm-www.apgea.army.mil/ento/TG208/TOC.HTM

Why So Effective• Heat penetrates all equipment harborage• Gentrol® is an excellent complement• Perhaps?

– Population reduced below growth threshold – Interferes with chemical comunication

Page 21: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Exotic Turkish land snailExotic Turkish land snail((Monaca Monaca syriacasyriaca))

Native land snailNative land snail((SuccineaSuccinea camestriscamestris))

Page 22: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 23: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Treatment Trial No. 1: Temperature Profile for Snail Control Project, 20 Ft. Metal Military Shipping Container, Sunny Pt., NC, 11 May 2000.

40

60

80

100

120

140

160

180

T T+10 T+20 T+30 T+40 T+50 T+60 T+70 T+80 T+90 T+100 T+110 T+120 T+130 T+140

Time (Minutes)

Tem

pera

ture

(°F)

Ch01 ""

Ch02 ""Ch03 ""Ch04 ""Ch05 ""Ch06 ""Ch07 ""Ch08 ""Ch09 ""Ch10 ""

Ch11 ""Ch12 ""Ch13 ""Ch14 ""Ch15 ""Ch16 ""Ch17 ""Ch18 ""

Ch19 ""Ch20 ""Ch21 ""Ch22 ""Ch23 ""Ch24 ""Ch25 ""Ch26 ""Ch27 ""

Ch28 ""Ch29 ""Ch30 ""Ch31 "

Ambient Air Temp

1 hr 2 hr

Wood flooring, Interior

Heater Output #1 Heater Output #2

Target Temp.

Figure 5.

Page 24: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Mortality of Snails exposed to average air temperature of 129 deg. F

0

10

20

30

40

50

60

70

80

90

100

Control 20 Minutes 40 Minutes 60 Minutes 80 Minutes

Turkish Snails

Native Snails

Page 25: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Snail Trial Conclusions

• Laboratory studies of thermal death point needed

• We can heat the exterior of containers in a windproof enclosure– Quickly 2 – 3 hours– Without damaging contents inside– Inexpensively, $25 energy cost

• Future trials with USDA planned

Page 26: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Thermal Chamber

• Collaborative effort with ToppPortable Air and Defense Logistics Agency

• Goal: Find an alternative to fumigation for commodity pest

Page 27: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 28: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Eight Pallets of 20-lb Poly Pack Boxes of Macaroni – 4 Tons

Page 29: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Patent Pending

Page 30: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 31: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 32: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Figure 8. Temperature Profile within 4 Tons of Palletized Macaroni,Chamber Air Temperature 140ºF (60ºC)

0

20

40

60

80

100

120

140

0 3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48

Time (Hours)

Tem

pera

ture

(ºF)

Pal 1, Tier 1, CtrPal 1, Tier 3, CtrPal 1, Tier 5, CtrPal 2, Tier 1, CtrPal 2, Tier 3, CtrPal 2, Tier 5, CtrPal 2, Tier 5, Rt FtPal 3, Tier 1, CtrPal 3, Tier 3, CtrPal 3, Tier 5, Lt BkPal 4, Tier 1, CtrPal 4, Tier 3, CtrPal 4, Tier 5, Rt BkPal 5, Tier 1, CtrPal 5, Tier 3, CtrPal 5, Tier 5, CtrPal 5, Tier 5, Lt BkPal 6, Tier 1, CtrPal 6, Tier 3, CtrPal 6, Tier 5, CtrPal 6, Tier 5, Rt BkPal 7, Tier 1, CtrPal 7, Tier 3, CtrPal 7, Tier 5, CtrPal 7, Tier 5, Lt BkPal 8, Tier 1, CtrPal 8, Tier 3, CtrPal 8, Tier 5, CtrPal 8, Tier 5, Rt Bk

60ºC

48.9ºC

15.6ºC

Heater Turned Off

Target Temperature Reachedin All Pasta Products within 40 hrs: Total Energy Cost of $16 or 40 cents/hr.

Page 33: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 34: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature
Page 35: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

2nd Generation Thermal Chamber Results

• All product meet target temperature without exceeding the upper limit

• All insects dead• No degradation of taste, color, or

cooking characteristics• Simple inexpensive operation

Page 36: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Pine Wilt DiseasePine Wood Nematode (Bursaphelenchusxylophilus (pine chips, unseasoned lumber, packing-case wood)

Insect Vectors: Bark Beetles and Sawyer Beetles(pallets, crates, dunnage)

USA Distribution: 36 States

International Distribution: Canada, Mexico, Japan, China, S. Korea

Effective October 2001, wood packing entering European Union must be heat treated to 56° C for 30 minutes

Whitespotted sawyer

Page 37: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

Patent Pending

PEST-HEAT® Thermal Pest Management Chamber

PEST-HEAT® Thermal Pest Management Chamber

Page 38: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

3rd Generation Thermal Chamber • All seasoned wood pallets meet target

temperature within 4 hours– 3 run per day capacity

• Approved by USDA-APHIS for the “56/30” treatment process

• Does not affect pallet service life• Energy cost 5 cents per pallet• Additional information: http://pestheat.com

Page 39: Thermal Control of THERMAL CONTROL OF INSECTS …...Pal 8, Tier 1, Ctr Pal 8, Tier 3, Ctr Pal 8, Tier 5, Ctr Pal 8, Tier 5, Rt Bk 60ºC 48.9ºC 15.6ºC Heater Turned Off Target Temperature

THERMAL PEST CONTROL

• Clearly it has a place• Move a lot of controlled hot air quickly• Recognize it’s limitations