the ventilation of the future.. what is ec? ac – asynchronous motor

25
The ventilation of the future.

Upload: vivian-heath

Post on 25-Dec-2015

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The ventilation of the future.. What is EC? AC – Asynchronous motor

The ventilation of the future.

Page 2: The ventilation of the future.. What is EC? AC – Asynchronous motor

What is EC?

AC – Asynchronous motor

Page 3: The ventilation of the future.. What is EC? AC – Asynchronous motor

EC – Electronically commutated motor

Page 4: The ventilation of the future.. What is EC? AC – Asynchronous motor

EC motor-driven fans

The use of energy efficient, EC-motor driven, fans results in higher efficiencies.

Easy control: CO2

Humidity

Temperature

Pressure

Constant air volume

Stepless speed control

EC on average uses 30% less power than AC

In some applications in excess of 50%

Page 5: The ventilation of the future.. What is EC? AC – Asynchronous motor

Energy consumption

Page 6: The ventilation of the future.. What is EC? AC – Asynchronous motor

Speed control

Page 7: The ventilation of the future.. What is EC? AC – Asynchronous motor

Efficiency

Page 8: The ventilation of the future.. What is EC? AC – Asynchronous motor

Legislation

EU adopts The Kyoto Protocol

Aim:

• Reduce emissions by 20% by 2020

Directive:

• Mandatory for all 27 EU countries

• All fans sold or imported in Europe

Page 9: The ventilation of the future.. What is EC? AC – Asynchronous motor

EuP/ErP

Lot 6 Lot 10 Lot 11

Roof and box fans

Fans < 125 W

Fans125 W to 500 kW

EuP / ErP

Motors0.75 kW to 500 kW

2010 2011 2012 2013 2014 2015 2016 2017

Page 10: The ventilation of the future.. What is EC? AC – Asynchronous motor

EuP/ErP – Lot 11

Lot 6 Lot 10 Lot 11

Roof and box fans Ventilatoren< 125 W

Fans125 W to 500 kW

EuP / ErP

2010 2011 2012 2013 2014 2015 2016 2017

IE2

Motors0.75 kW to 500 kW

IE3IE3

Page 11: The ventilation of the future.. What is EC? AC – Asynchronous motor

Lot 11 - Motors

How does Lot 11 impact motors?

2010 2011 2012 2013 2014 2015 2016 2017

IE3 > 7.5 KW

IE2 IE3 > 0.75 KW

Page 12: The ventilation of the future.. What is EC? AC – Asynchronous motor

Legislation – Motors

• Implemented 16th June 2011- IE2

• IEC - International Electrotechnical Commission

• IEC 60034-2-1: 2007

• IEC 60034-2: 1996 (EFF) EXP Nov 1st 2010

Page 13: The ventilation of the future.. What is EC? AC – Asynchronous motor

Motor efficiencies

High Efficiency

Low Efficiency

EFF 1

EFF 2

IE4 Super Premium (Proposed)

IE3 Premium Efficiency

IE2 High Efficiency

IE1 Standard Efficiency

Page 14: The ventilation of the future.. What is EC? AC – Asynchronous motor

Exceptions

Page 15: The ventilation of the future.. What is EC? AC – Asynchronous motor

Exceptions

Page 16: The ventilation of the future.. What is EC? AC – Asynchronous motor

Lot 11 - Fans

Lot 6 Lot 10 Lot 11

Roof and box fans Fans< 125 W

Fans125 W to 500 kW

EuP / ErP

2010 2011 2012 2013 2014 2015 2016 2017

? ?

Efficiency requriement 1

Efficiency requirement 2

Page 17: The ventilation of the future.. What is EC? AC – Asynchronous motor

EuP directive – Lot 11

Between 0.125KW and 500KW input

Applies to:

• Fans integrated in a unit

• Stand alone units

Page 18: The ventilation of the future.. What is EC? AC – Asynchronous motor

What fans are affected?

All fan typesAll fan types

• Axial fans

• Forward curved centrifugal/radial bladed

• Backward curved centrifugal without housing

• Backward curved centrifugal with housing

• Cross flow

• Mixed flow

Page 19: The ventilation of the future.. What is EC? AC – Asynchronous motor

Exceptions

• Atex fans

• Emergency smoke extract

• Railways (Transportation)

• Kitchen hoods - Less than 280W

• Laundry dryers - Less than 3KW

• Box fans

Page 20: The ventilation of the future.. What is EC? AC – Asynchronous motor

ExceptionsBrussels, XXX

C(2010) YYY finalArticle 1Subject matter and scope1. This Regulation establishes ecodesign requirements for the placing on the market or putting into service of fans, including those integrated in other energy-related products as covered by Directive 2009/125/EC.2. The Regulation shall not apply to fans integrated in:(i) products with a sole electric motor of 3 kW or less where the fan is fixed on the same shaft used for driving the main functionality;(ii) laundry and washer dryers ≤ 3 kW maximum electrical input power;(iii) kitchen hoods < 280 W total maximum electrical input power attributable to the fan(s).3. This Regulation shall not apply to fans which are:(a) designed specifically to operate in potentially explosive atmospheres as defined in Directive 94/9/EC(b) designed for emergency use only, at short-time duty, with regard to fire safety requirements set out in Directive 89/106/EC(c) designed specifically to operate:(i) a. where operating temperatures of the gas being moved exceed 100ºC;

b. where operating ambient temperature for the motor, if located outside the gas stream, driving the fan exceeds 65°C;(ii) where the annual average temperature of the gas being moved and/or the operating ambient temperature for the motor, if located outside the gas stream, are lower than -40ºC;(iii) with a supply voltage >1 000 V AC or >1 500 V DC;(iv) in toxic, highly corrosive or flammable environments or in environments with abrasive substances.

Page 21: The ventilation of the future.. What is EC? AC – Asynchronous motor

Existing systems

• Do not have to replace or modify before the ErP start date.

• ErP non-compliant fans can be retrofitted up to 31st Dec 2014.

• After 1st Jan 2015 these fans will also have to comply with the then current ErP directive.

Page 22: The ventilation of the future.. What is EC? AC – Asynchronous motor

What now?

• Fans will have to adhere to the minimum efficiency levels.

• Defined at the best operating point based on electrical power input.

• Efficiency of the complete fan is assessed.

Page 23: The ventilation of the future.. What is EC? AC – Asynchronous motor

Fan types Measurement category

Efficiency category

Power range P in kW

Target energy efficiency Efficiency grade

(N) ab 01.01.2013

Efficiency grade

(N) ab 01.01.2015

Axial fan A, C static 0.125 ≤ P ≤ 10 ηtarget = 2.74 ∙ ln(P) – 6.33 + N 36 40

10 < P ≤ 500 ηtarget = 0.78 ∙ ln(P) – 1.88 + N

B, D total 0.125 ≤ P ≤ 10 ηtarget = 2.74 ∙ ln(P) – 6.33 + N 50 58

10 < P ≤ 500 ηtarget = 0.78 ∙ ln(P) – 1.88 + N

Centrifugal forward curved fan and centrifugal radial bladed fan

A, C static 0.125 ≤ P ≤ 10 ηtarget = 2.74 ∙ ln(P) – 6.33 + N 37 44

10 < P ≤ 500 ηtarget = 0.78 ∙ ln(P) – 1.88 + N

B, D total 0.125 ≤ P ≤ 10 ηtarget = 2.74 ∙ ln(P) – 6.33 + N 42 49

10 < P ≤ 500 ηtarget = 0.78 ∙ ln(P) – 1.88 + N

Centrifugal backward curved fan without housing

A, C static 0.125 ≤ P ≤ 10 ηtarget = 4.56 ∙ ln(P) – 10.5 + N 58 62

10 < P ≤ 500 ηtarget = 1.1 ∙ ln(P) – 2.6 + N

Centrifugal backward curved fan with housing

A, C static 0.125 ≤ P ≤ 10 ηtarget = 4.56 ∙ ln(P) – 10.5 + N 58 61

10 < P ≤ 500 ηtarget = 1.1 ∙ ln(P) – 2.6 + N

B, D total 0.125 ≤ P ≤ 10 ηtarget = 4.56 ∙ ln(P) – 10.5 + N 61 64

10 < P ≤ 500 ηtarget = 1.1 ∙ ln(P) – 2.6 + N

Mixed flow fan A, C static 0.125 ≤ P ≤ 10 ηtarget = 4.56 ∙ ln(P) – 10.5 + N 47 50

10 < P ≤ 500 ηtarget = 1.1 ∙ ln(P) – 2.6 + N

B, D total 0.125 ≤ P ≤ 10 ηtarget = 4.56 ∙ ln(P) – 10.5 + N 58 62

10 < P ≤ 500 ηtarget = 1.1 ∙ ln(P) – 2.6 + N

Cross flow fan B, D total 0.125 ≤ P ≤ 10 ηtarget = 1.14 ∙ ln(P) – 2.6 + N 13 21

10 < P ≤ 500 ηtarget = N

Page 24: The ventilation of the future.. What is EC? AC – Asynchronous motor

Regulation enforcement

• UK Market Surveillance Authority (MSA)

• Eco-design directive

• National Measurement Office

For more information: www.rohs.gov.uk/EUP/

Page 25: The ventilation of the future.. What is EC? AC – Asynchronous motor

End of presentationEnd of presentation

Thank you for listening.Thank you for listening.