the quality assurance and reliability testing (qart) lab at cern
DESCRIPTION
The Quality Assurance and Reliability Testing (QART) Lab at CERN. Outline. Purpose of Lab Lab site Personnel and Equipment Activities The DSF and Bonding Lab Conclusions. A. Honma , CERN PH/DT. Purpose of Lab. CERN DSF QART and Bonding Lab. - PowerPoint PPT PresentationTRANSCRIPT
CMS Upgrade Meeting, A. Honma 1
The Quality Assurance and Reliability Testing (QART) Lab at
CERNA. Honma, CERN PH/DT
26 April 2010
Purpose of Lab Lab site Personnel and EquipmentActivities The DSF and Bonding Lab Conclusions
Outline
CMS Upgrade Meeting, A. Honma 2
Purpose of Lab• Was created from the White Paper initiative of the DG in 2007, R&D for
LHC upgrades
• Part of WP6: Interconnect Technology and QA (for LHC silicon detector upgrades)
• Located in the PH Departmental Silicon Facility (DSF) in Bldg 186
• Common QA lessons learned from LHC silicon detector construction should be documented. Avoid mistakes in the LHC detector upgrades and provide infrastructure and expertise to apply QA and reliability testing for the upgrade R&D and construction phases.
• QA ⇒ Planning and procedures common to ANY project. Broader scope for lab: any LHC detector, non-LHC detectors, other CERN projects
• Reliability Testing has become essential owing to lack of accessibility and long expected life times of detectors and electronics
26 April 2010
CERN DSF QART and
Bonding Lab
CMS Upgrade Meeting, A. Honma 326 April 2010
CERN DSF QART and
Bonding Lab Lab SiteCERN DSF QART and
Bonding Lab
Location of QART lab is inside B186-R (ground floor) in the Departmental Silicon Facility
B186
CMS Tracker Integration Facility
Departmental Silicon Facility
Bldg 186
High Bay Hall
QART Lab
CMS Preshower Final Assembly
CMS Upgrade Meeting, A. Honma 4
QART Website: http://bondlab-qa.web.cern.ch/bondlab-qa/QA.html
Personnel (2.5 FTE):• 1 proj. assoc. (F. Manolescu) – 100%• 1 fellow (A. Drozd) – 100%
Equipment:
• Climatic chamber (large volume, fast temp. cycling with humidity control)• Thermal cycling chamber (small volume, med. speed, no humidity control) • Vibration tester (mono-axial shaker can deliver 10G’s to 10Kg payload)• Infra-red thermal imaging video camera• High magnification stereo-microscope on probe station with video camera• Small aperture permanent magnet with B=0.7T for high mag field studies• Die shear tester / bond wire pull tester
26 April 2010
CERN DSF QART and
Bonding LabPersonnel and EquipmentCERN DSF
QART and Bonding Lab
• 1 physicist (A. Honma) – 30%• 1 technician (I. McGill) – 20%
CMS Upgrade Meeting, A. Honma 5
+60°C
-30°C
+20°C
65 min
TOTEM hybrid thermal cycle
26 April 2010
CERN DSF QART and
Bonding LabEquipment: Climatic Chambers
CERN DSF QART and
Bonding Lab
Climatic ChamberTemp range: -70°C to +180°CHum range: 10% to 95%RHHeating speed: 15°C/minCooling speed: 11°C/min
Thermal Cycling ChamberTemp range: -40°C to +180°CHeating speed: 5°C/minCooling speed: 6°C/min
Tests:•Thermal cycling•Accelerated lifetime•Humidity tolerance•Cold tolerance•Stress screening•Environment simulation
CMS Upgrade Meeting, A. Honma 626 April 2010
CERN DSF QART and
Bonding LabEquipment: Vibration TesterCERN DSF
QART and Bonding Lab
Mono-axial shaker with control system and analysis tools for Random, Sine, Shock, and Recorded vibration inputs. Can perform:• Destructive testing• Stress screening• Modal analysis• Playback of transport and handling vibrations
and shocks• 30cm x 30cm head expander allows testing of
large objects (ex.: CMS silicon tracker module)
Accelerometer on silicon sensor
Acceleration frequency spectrum
CMS Upgrade Meeting, A. Honma 726 April 2010
CERN DSF QART and
Bonding LabEquipment: IR Video CameraCERN DSF
QART and Bonding Lab
High sensitivity (0.1°K) thermal imaging IR video camera. Expected uses:• Identifying hot spots on silicon sensors, thermal run-away conditions(?), …• Heat flow study on front-end PCBs and detector modules• Many other possible uses …
Example #2: Malfunctioning heating loop was easily located on one of CMS Tracker Endcap panels.
Example #1: Motherboard of a PC. Frame capture from the video output.
4: Hottest point in frame
1: and 2: User selectable measurement points (3 max)
Temperaturemeasuremen
ts
CMS Upgrade Meeting, A. Honma 826 April 2010
CERN DSF QART and
Bonding Lab
Equipment: High Magnification Zoom Stereo-microscope
CERN DSF QART and
Bonding Lab
• High magnification (up to 320x) needed for silicon sensors (pixel or strips) and for (bare) read-out chips.• Stereo needed for 3-D structure identification.• Video camera useful if object’s visual aspect has time dependence and for documentation.• Possibility to probe the observed object.
Example: Poor wire bonding quality can often be spotted from surface details and form of welded bond “foot”. Below: right-most bond foot is heavily over-deformed (flattened).
50μm
acceptable marginal rejected
Leica MZ16
CMS Upgrade Meeting, A. Honma 926 April 2010
CERN DSF QART and
Bonding LabEquipment: High Field MagnetCERN DSF
QART and Bonding Lab
Motivation: CDF silicon strip detector had broken bond wires from vibration owing to AC current at resonant frequency of wires (10-30KHz) in high B field (1.4T).
0.7 T dipole field using neodymium magnets.Plan to get a small electromagnet with up to 2T
Resonant oscillation on bond wire of 3.5mm length found at 6.8KHz.
Both ATLAS and CMS have determined the risk of existing bonds to be minimal but have taken precautions to avoid fixed frequency triggers.
ATLAS has published an analysis for at-risk bonds in ATLAS silicon detectors. But no known systematic study of effects of wire loop properties and bonding quality on breakage risk. Try to quantify more generally these risks.
In agreement with FEA calculations
CMS Upgrade Meeting, A. Honma 10
Activities, Past/PlannedAll equipment is ready for use by the user community. Although priority is given to the LHC experiments silicon detector upgrade projects, other upgrade projects, other experiments, and other CERN projects can use the lab. Examples of tests done or planned:• Thermal cycling done on front-end electronics (CMS, TOTEM, ALICE),
sensors/chips (Medipix), standard PCBs (LHC quench protection system, CMS Preshower), small mechanical structures. Tests can be passive or active (users provide control and powering electronics).
• Accelerated aging (timed heat soak) performed for corrosion (with humidity), metal migration (bond wire pads), oxidation.
• The IR video camera used for hot spot detection on silicon sensors.• We plan to do transport and handling vibration damage studies for
silicon detector modules and components. This will include real recordings of transport examples (plane, truck, train) for playback.
• Continue wire vibration damage studies in magnetic field.
26 April 2010
CERN DSF QART and
Bonding Lab
The Departmental Silicon Facility (DSF)
The QART lab shares clean room space and personnel with the bond lab. The QART lab also uses space in the non-clean DSF areas.
26 April 2010 CMS Upgrade Meeting, A. Honma 11
CERN DSF QART and
Bonding Lab
Bond and QART LabATLAS RD50
Technical Rooms and Airlocks
Non-Clean Areas
Departmental Silicon Facility (2010)
RD50
ALICE
LHCb and Medipix
DSF Clean Room (~270m2 usable)
LHCb CMS
~30m
~85m
~65m
Access Way
PEG
PE
PG
PEG
PE
PEG
PEGPEG
P
PPE
P
P=power, E=Ethernet, G=gas lines (N2)
Clean room boundary
CMS Upgrade Meeting, A. Honma 12
The Bonding LabThe Bonding Lab is a CERN shared facility which is dedicated to:•Ultrasonic wedge wire bonding with aluminium wire.•Pull testing of wires (destructive and non-destructive).•Die attach (chip and small detector gluing).•Encapsulation of wire bonds (new).
26 April 2010
CERN DSF QART and
Bonding Lab
2 Delvotec 6400 ultrasonic wedge wire bonding machines
IJ Fisnar 7300-LF Glue (Encapsulation) dispenser
Cammax DB600 die bonder with heated chuck
Dage 4000 bond wire pull tester and die shear tester
CERN Bond lab did about 20% of CMS Tracker bonding +
100% of Preshower. Now doing sensor, chip and radmon
R&D for CMS.
CMS Upgrade Meeting, A. Honma 13
Conclusions• Quality Assurance and Reliability Testing (QART) Lab is now equipped
with all foreseen major test apparatus.• Lab personnel are trained or in training for test equipment. We are able
to provide test services (for smaller jobs) or advice and assistance (for larger jobs) to the LHC experiments upgrade projects.
• We have a resource library and experience concerning quality assurance for detector projects. We are always interested in learning from others experience as concerns quality issues.
• Reliability testing is a critical step in assuring that the components and the systems that cannot be easily repaired or replaced will be able to function over the required lifetime.
• Please feel free to contact us for questions, discussions, planning and requests for QA, reliability testing, equipment usage, wire bonding and chip gluing.
26 April 2010
CERN DSF QART and
Bonding Lab
http://bondlab-qa.web.cern.ch/bondlab-qa/QA.html