the performance of the cms hadron calorimeter with cosmic muons vasken hagopian
DESCRIPTION
11 th International Conference on Advanced Technology and Particle Physics Villa Olmo (Como - Italy), October 5 - 9, 2009. THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian Florida State University/ Note Dame University - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/1.jpg)
H C A L
11th International Conference on Advanced
Technology and Particle Physics Villa Olmo (Como - Italy), October 5 - 9, 2009
THE PERFORMANCE OF THE CMS HADRON CALORIMETER with
COSMIC MUONS
Vasken HagopianFlorida State University/ Note Dame University
For the CMS Hadron Calorimeter Collaboration
15 October 2009 11th International Conference, COMO, Italy
![Page 2: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/2.jpg)
H C A L
CERN in Geneva, Switzerland
CMS
Test Beam
25 October 2009 11th International Conference, COMO, Italy
![Page 3: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/3.jpg)
H C A L
HCAL DetectorPerformance
• In 2008 about 300 million cosmic muons were recorded with the 3.8 tesla magnet on called CRAFT (Cosmic Run At Four Tesla) and another 3 million cosmic muons at Zero field (CRUZET).
• OUTLINE• Calibration using ’s𝛍 • Time alignment• Electronic noise
35 October 2009 11th International Conference, COMO, Italy
![Page 4: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/4.jpg)
H C A L
The CMS Detector
HF
HOHB
HE
45 October 2009 11th International Conference, COMO, Italy
![Page 5: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/5.jpg)
H C A L
End Cap & HO
55 October 2009 11th International Conference, COMO, Italy
![Page 6: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/6.jpg)
H C A L
STATUS OF HCAL
• HCAL has various sub-systems: Barrel HB. End Cap HE. Outer calorimeter HO. Forward HF, Very forward CASTOR AND ZDC.
• This presentation covers only HB, HE and HO.
• HCAL IS NOW COMPLETELY ASSEMBLED IN CMS.
• Portions of each subsystem was tested and calibrated in the CERH H2 test beam.
65 October 2009 11th International Conference, COMO, Italy
![Page 7: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/7.jpg)
H C A L
HADRON CALORIMETER
FEE are locations of Front End Electronics.Right end of beam line is the intersection point.
ECAL modules are inside HCAL and the combined informationof ECAL and HCAL determines the hadron energy.
IP
75 October 2009 11th International Conference, COMO, Italy
![Page 8: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/8.jpg)
H C A L
COSMIC MUONS
• 300 million cosmic muons were taken with the CMS magnet on in 2008 and a similar number with the magnet off.
• In Sept 2008, for a few days LHC circulated 450 GeV/c beam. We observed beam gas events and later the beam was stopped by collimators 150 m from CMS. These “splash” events were used for timing.
85 October 2009 11th International Conference, COMO, Italy
![Page 9: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/9.jpg)
H C A L
Calorimeter Calibration
• Procedure for calibration:
• Calibration using both ECAL and HCAL.
• Step 1 is in the test beam (2006 for HB, HO, HF and 2007 for HE). Using electrons, pions and muons.
• Radioactive wire sourcing of each tile (HB and HE) before lowering CMS into cavern.
• Cosmic muons for final calibration before LHC beam.
95 October 2009 11th International Conference, COMO, Italy
![Page 10: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/10.jpg)
H C A L
Cosmic muon energy
Cosmic ’s.𝛍 p = 7 to 300 GeV/c. Not energy corrected
105 October 2009 11th International Conference, COMO, Italy
![Page 11: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/11.jpg)
H C A L
Cosmic muon energy
Left: Cosmic momentum distribution𝛍Right: Energy loss (dE/dx) vs. p and comparison to expected value
115 October 2009 11th International Conference, COMO, Italy
![Page 12: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/12.jpg)
H C A L
Calibration constants refined using 2008 data. Barrel only.2009 data: Pµ = 5-100 GeV/c. Signal corrected for path length and momentum to 25 GeV/c.
Mean response for HB+/HB- is in good agreement
125 October 2009 11th International Conference, COMO, Italy
![Page 13: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/13.jpg)
H C A L
First LHC Beam in 2008
“Splash” Event
Wed, 10 Sept. 2008“Splash” events observed when beam (450 GeV, 4109 p) struck collimators 150m upstream of CMS Halo muons observed on (uncaptured and captured) started passing through CMS
Data-taking with LHC beam.
Data-taking with LHC beam.
135 October 2009 11th International Conference, COMO, Italy
![Page 14: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/14.jpg)
H C A L
LHC Beam: Beam GasEnergy Deposit in HE
HCAL Endcap: un-captured and RF-captured circulating beam
145 October 2009 11th International Conference, COMO, Italy
![Page 15: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/15.jpg)
H C A L
HCAL Electronic NoiseData Box (RBX) and HPD
RBX Noise: noise hits in multiple HPDs in a RBX 40GeV < E < 420GeV HPD Noise: noise hits in only one HPD in a RBX ion feedback (nhits < 10 ) below 40 GeV discharge (nhits>=10) above 420 GeV
155 October 2009 11th International Conference, COMO, Italy
![Page 16: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/16.jpg)
H C A L
Fake Missing Transverse Energy in CRAFT Data
5 October 2009 11th International Conference, COMO, Italy
16
Algorithms are off line software that reduce the contribution dueto noise.
![Page 17: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/17.jpg)
H C A L
Timing alignment
• Laser distribution aligns to a few nsec.
• Front end electronics can delay time in 1 nsec steps.
• Time (start) of event depends on event energy.
• Final alignment adjustment using “splash” events.
• Time alignment now is about 1 nsec.
175 October 2009 11th International Conference, COMO, Italy
![Page 18: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/18.jpg)
H C A L
Timing Corrections using “Splash” Events
5 October 2009 11th International Conference, COMO, Italy
18
![Page 19: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/19.jpg)
H C A L
Time Filtering
5 October 2009 11th International Conference, COMO, Italy
19
![Page 20: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/20.jpg)
H C A L
SiPM
5 October 2009 11th International Conference, COMO, Italy
20
![Page 21: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/21.jpg)
H C A L
HO Upgrade
215 October 2009
•HO measures energy leakage from barrel calorimeter.•No direct calibration. Equalization using 𝛍’s.•Most HPD noise is in HO as axes are not aligned well with magnetic field direction.•Investigating SiPM as replacement of HPD’s.
![Page 22: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/22.jpg)
H C A L
Other tests
• HCAL is very stable in time and energy during operation.
• Zero suppression is effective in reducing data to less than 20% occupancy for nominal luminosity.
• Splash events confirmed calibration constant that give uniform energy.
5 October 2009 11th International Conference, COMO, Italy
22
![Page 23: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/23.jpg)
H C A L
Physics of CMS
• Standard model breaks down at E ~ 1 TeV
• New physics is expected at TeV scale.
• Dark matter search is critical; Calorimeter
required to measure missing energy.
• Discoveries should revolutionize particle
physics and cosmology & provide window to
physics at unification scale.235 October 2009 11th International Conference,
COMO, Italy
![Page 24: THE PERFORMANCE OF THE CMS HADRON CALORIMETER with COSMIC MUONS Vasken Hagopian](https://reader036.vdocuments.mx/reader036/viewer/2022062315/568151bb550346895dbfe931/html5/thumbnails/24.jpg)
H C A L
Conclusion
• HCAL assembly and installation completed. Now initial calibration complete. Final calibration with collisions.
• CMS will soon start taking data
• Already working on upgrade for increased luminosity. Scintillators will be damaged and other components will have reduced effectiveness.
245 October 2009 11th International Conference, COMO, Italy