I MPLANTSMEDICAL DEVICES & DEVELOPMENT
1
Nova Implants Medical Devices & Development Ltd. is a young, innovative,
expanding high-tech production and research company. Specializing in the
development of dental solutions and advanced production techniques. Nova
Implants has over a decades experience in the field, and is recognized by
the industry for its high quality products and constant clinical successes.
Nova Implants continuously strives to design, develop and manufacture
implants and prosthetics of the highest quality by implementing the latest
advancement in implant science. Nova Implants market a comprehensive
range of dental implants and superstructures.
Nova Implants surface treatment is carried out by one of the worlds
leading laboratories who have over ten years experience and have
produced thousands of implants with a high level of success. Nova Implants maintains a meticulous quality control system and complies
with major quality control standards.
The implants, prosthetics and accompanying aids manufactured by Nova
Implants, naturally integrate into the body, reduce healing time, minimize
rejections, prevent complications and provide durability for years. The
surface of all Nova’s implants undergo a complex procedure which
significantly increases the success of the osseointegration process.
The Nova Implants consulting team offers all-round professional and
technical support. Nova Implants continuously strives to improve its
products and simplify your procedures, providing the patients with reliable
long-lasting successful results.
All specifications in this catalog are subject to change without prior notice. All models shown are for simulation purposes.
2
About Us 1
Contents 2
RBM Dental Impants by CST Process 3-8
NOVA Implants System PSI 9-11
NOVA Implants System PCI 12-14
NOVA One Stage System DV 15-16
ORTHODONTIC ANCHOR SCREW 17-18
HEALING CAPS 19-20
Standard 19
Narrow 19
Wide 19
Premium Healing Caps 20
PROSTHETIC ABUTMENTS 21-26
Standard Straight 21
Standard Straight Long 21
Standard Straight Narrow 21
Standard with Shoulder 22
Anatomic Straight 22
NEW Anatomic Straight 22
Angulated 15˚ 23
Angulated 15 ˚ Narrow 23
Anatomic Angulated 15˚ 23
Angulated 25˚ 24
Angulated 25 ˚ Narrow 24
Anatomic Angulated 25˚ 24
NEW Anatomic Angulated 15˚ 25
NEW Anatomic Angulated 25˚ 25
Angulated 35˚ 26
Angulated 45˚ 26
BALL ATTACHMENTS 27
Standard 27
Covers 27
IMPRESSION COPINGS 28-29
Closed Tray 28
Open Tray 29
Abutment Screws 29
ESTHETIC ABUTMENTS 30
Components 30
Plastic Sleeve 30
Screws 30
ABUTMENT SLEEVES 31
Delrin Hex & Non Hex 31
Delrin Wide Hex & Non Hex 31
Custom Titanium Castable 31
PLASTIC ANATOMIC ABUTMENTS 32
Anatomic Angulated 15˚ 32
Anatomic Angulated 25˚ 32
ZIRCONIUM ABUTMENTS 33
Standard 33
Angulated 15˚ 33
Angulated 25˚ 33
IMPLANT ANALOGS 34
DRILLS & COUNTERSINKS 35
IMPLANT TOOLS 36
IMPLANT TOOLS 37
TOOL KIT 37
Packaging 38
Symbols 38
Opening Instructions 39
Procedures 40
User Instructions 41
NOVA Implants has completed technological validation of RBM (Resorbable Blasting Media) Process, based on its CST (Comprehensive Surface Treatment) Process. From now, our customers may benefit from well known advantages of RBM implants.
RBM surface is featured by extensively developed roughness and no biocompatibility obstructions, thanks to using of biocompatible Calcium Phosphate blasting media. Calcium Phosphates are easily dissolved, leaving well textured surface completely free of conta- minants. Additionally, RBM does not need strong acids for removing of blasting media remains, which contributes to implants biocompatibility as well. NOVA Implants’ RBM surface undergoes completing surface treatment by citric acid, also compatible to live textures.
NOVA Implants RBM CST Process uses an apatite born Calcium Phosphate having approximate chemical composition of Ca3(PO4) (Tri-Calcium Phosphate), blasted at automatic blasting machine allowing uniform and repeatable surface of implants. The clean- ing, washing-out and washing stages include using of Ultrasonic Baths with De-ionized Water of high purity , air drying is carried out in clean room class 10,000, while quality control at all stages of the treatment is performed including on-line SEM-EDS control and periodical XPS and optical profilometry tests.
NOVA RBM implants demonstrate high surface performances, and when checked by advanced physical instruments (SEM, EDS, XPS, Optical Profilometer) are revealed to be fully identical to the surface performances of implants manufactured by the leaders in the field:
1. The surface structure (morphology) of the NOVA Implants RBM dental implants, as exposed by SEM microphotographs, is featured by highly developed surface porosity.
2. The surface roughness of the NOVA Implants RBM dental implants is well-defined and uniform. The main roughness parameter Ra has good acceptable value of 1.9microns.
3. The surface purity of the NOVA Implants RBM dental implants, as exposed by SEM microphotographs and checked by EDS-SEM instrument, is nearly absolute: no inclusions or contaminations are detected, any point of the surface is revealed to be pure Titanium alloy.
4. The surface chemical composition of the NOVA Implants RBM dental implants, as analyzed by XPS instrument, represents well acceptable values of the main elements usually found on the dental implants surface underwent blasting and blasting media cleaning.
RBM dental implants byCST Process
Su
mm
ary
3
Following years of experience in developing, engineering and industrial running of its alumina- blasting-double-etching CST Process, successfully operated during several years for manufacturing hundred of thousands dental implants, NOVA Implants has entered the RBM processing as well, to contribute to the world spreading of this novel process and to allow its customers to benefit from it.
The RBM CST Process as presently validated is detailed in the appropriate NOVA Implants documents and consists of the following main stages of the implants’ treatment:
Quality control at all stages of the treatment, including on-lineSEM-EDS control and periodical XPS and optical profilometry tests.
The blasting media used in the Process is an apatite born Calcium Phosphate having approximate chemical composition of Ca3(PO4) (Tri-Calcium Phosphate) with hardness estimated as 5 by the Mohs’ scale of hardness, as compared to 9 for Alumina.
Washing from machining remains, including Ultrasonic Bathes and steam cleaning.
Calcium Phosphates Blasting for formation of surface morphology, using automatic blasting machine allowing uniform and repeatable blasted surface of implants.
After blasting washing.
Dissolution of the blasting media in diluted inorganic acid solutions not attacking Titanium.
Surface conditioning through replacement of inorganic acids by citric acid.
Ultimate washing, finally in Ultrasonic Bathe with DIW of high purity.
Air drying in clean room class 10,000.
RBM CST Process
Th
e P
roce
ss
The <300 μm particles of the apatite abrasive.
2 mm
4
RBM implants comparative tests - SEM general view
SEM (Scanning Electron Microscope) - General view, Magnification X 10
Lifecore BiomedicalRBM Implant
NOVA RBM Implantsample APA-S040912
NOVA RBM Implantsample 0812-1a-gamma
2 mm 2 mm
CONCLUSION: All three implants have gained identically clean microporous homogeneous surface.
SEM (Scanning Electron Microscope) - surface structure (morphology)
Lifecore BiomedicalRBM Implant
(X 500 magnification)
NOVA RBM Implantsamples APA-S040912 and
0812-1a-gamma (X 2000 mag.)
Osstem(**)RBM Implant
2 mm
MAGNIFICATION X
X 4000
X 2000
X 1000
CONCLUSION: All implants have an identical surface, and features intensive developed morphology with sharp boundaries, without special geometry.
Test Results of NOVA RBM implants, which show their full identity to other RBM implant leaders in the field.
* www. trycare.co.uk/techdata_pdfs/106.pdf
** www.chirurgiaorale.altervista.org/Ostem/ostem/RBM_Research.pdf
5
Roughness by optical profilometer
Test’s results of roughness measurement by optical profilometer, for NOVA Implants RBM implant, sample APA-P2-040912
TECHNION IIT Title:Note:
RqRaRvRpRt
Surface statistics
2.39 um1.94 um
-20.12 um16.10 um36.22 um
DateTimeMeasurement ModeFovObjectivePixel size
05/09/201211:15:43
VSR1.0 X50 X
193.12 mm
XYHtDistAngle
60.8331.874.42
---
-----
umumumum˚
6
Comparative Results
Comparative results of the main roughness parameter Ra value, for dental implant surface:
NOVA ImplantsOsstemLifecoreCompany
RBM implantRBM implantRBM implantImplant
Above test results(**)(*)Source
1.91.3-1.81.3Ra, microns
Veeco OpticalProfilometer
The Ra value as definedat the Osstem web pagefrom the above profileimage
Ra is calculated following the Lifecore web page definition: “Lifecore’s RBM surface offers approximately 250% greater surface roughness (Ra) than a traditional machined surface”, the last is roughly estimated as of 0.5 microns
Test instrumentor way ofderivation
Surface chemistry & purity of NOVA Implants RBM implants as tested by SEM-EDS (Scanning Electron Microscope and Energy Distribution Spectrum)
0812-3a-beta0812-1a-gammaAPA-S-040912NOVAImplants RBM sampleidentification:
SEM micro-photograph,magnification X500:
EDS (*):
* www. trycare.co.uk/techdata_pdfs/106.pdf
** www.chirurgiaorale.altervista.org/ostem/ostem/RBM_Research.pdf
Conclusion: The surface of NOVA Implants RBM implants has homogeneous roughness with Ra statistical value of 1.9 microns, within a range declared as optimal by leaders in the field.
Conclusion: SEM microphotographs show absolutely clean porous surface of the implants, while EDS chemical analysis at any point of the surface show regular chemical composition of Ti-Al-V alloy with no contaminations.
(*)The spectra were obtained from the random points on the surface as seen by the microphoto-graph, while absolutely identical spectra were revealed on any point of the tested surface. The high pick on the spectrum is responsible for Ti, the left small is responsible for Al, and the right small one for V.
7
Implant customers will benefit from RBM implants
The surface structure (morphology) of the NOVA Implants RBM dental implants, as exposed by SEM mi crophotographs, is identical to that of the leading companies in the field and is featured by highly developed surface porosity.
The surface roughness of the NOVA Implants RBM dental implants is well-defined and uniform. The main roughness parameter Ra has good acceptable value of 1.9 microns, which falls in the range of this parameter as declared by the leaders in the field.
The surface purity of the NOVA Implants RBM dental implants, as exposed by SEM micropho-tographs and checked by EDS-SEM instrument, is nearly absolute: no inclusions or contaminations are detected, any point of the surface is revealed to be pure Titanium alloy.
The surface chemical composition of the NOVA Implants RBM dental implants, as analyzed by XPS instrument, represents well acceptable values of the main elements usually found on the dental implants surface that underwent blasting and blasting media cleaning, and is comparable to that of the leaders in the field.
Conclusions:1.Main chemical components detected on the surface (Ti, O, C) are of identical level for both NOVA Implants and Osstem implants (Al and V at the NOVA Implants are on the usual level for Ti6Al4V alloy, while their absence in the Osstem case may point out on using of pure Titanium for implants’ manufacturing).2. Traces of Ca and P are remains of biocompatible blasting media (Calcium Phosphate) used in both cases.3. Other negligible traces are common for both cases and constitute remains of materials used at various stages of the surface treatment process.
Ben
efit
sChemical composition of dental implants surface as tested by X-ray Photoelectron Spectroscopy (XPS)
Element concentration, atomic %, as defined at the measure point by XPSsourceImplantCompany
PSiZnCaNVAICOTi
0.910.850.670.560.940.343.2522.0554.4715.97XPS testfor thisresearch
RBM implant,sample APAX-040912, topsection
NOVAImplants
000.650.530.610.603.0821.3755.7617.41XPS testfor thisresearch
RBM implant,sample APAX-040912, screw section
NOVAImplants
2.01.000.41.40020.854.619.8(*)RBM implantOsstem
www.chirurgiaorale.altervista.org/Ostem/ostem/RBM_Research.pdf
8
Implant System - PSI
Product IdentificationNAME DIAMETER LENGTH
PSI - 3.75 - L8
Nova Implants are taperd internal hex implants, designed to enable easy insertion while supporting excellent initial stability. The variable thread design enables self tapping, thus providing superb solutions for a variety of bone conditions.
All our implants are made of the titanium alloy Ti-6Al-4V ELI, in accordance with ASTM-F136-02. Titanium has the outstanding capability to integrate almost completely with the bone. This unique charactaristic coupled with its meatalorgic advantages of strength & endurance makes titanium the ideal implant material . In addition it can be precisely machined to ensure a range of implants that meets the requirements of modern state of the art Prosthetics. All our implants can be ordered with the regular SLA surface treatment or the new RBM more advanced surface treatment.
Nova Implants multi-design features offers an excellent solution for immediate placement and immediate loading. One platform fits all implant diameters. Packaging has been designed for quick identification and easy opening.
Nova Implants adhere to the highest international standards of manufacturing and have the ISO standards Institute and CE approval.Clinical Benefits: • Better control during placement.• Greater initial placement stability.• Self drilling, super self-tapping feature.• Self-condensing.• Self-directing in line of insertion.
Color Identification - implants
RED3.30mm
BLUE3.75mm
GREEN4.20mm
BLACK5.00mm
BROWN6.00mm
9
Implant System - PSI
PSI-3.3-L16PSI-3.3-L13PSI-3.3-L11.5PSI-3.3-L10PSI-3.3-L8Cat. No.
16 mm13 mm11.5 mm10 mm8 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
ø 3.3 mm
Length
ø 3.3 mm
ø 3.75 mm
Length
ø 3.75 mm
ø 4.2 mm
Length
ø 4.2 mm
PSI-3.75-L16PSI-3.75-L13PSI-3.75-L11.5PSI-3.75-L10PSI-3.75-L8Cat. No.
16 mm13 mm11.5 mm10 mm8 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
PSI-4.2-L16PSI-4.2-L13PSI-4.2-L11.5PSI-4.2-L10PSI-4.2-L8Cat. No.
16 mm13 mm11.5 mm10 mm8 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
10
Implant System - PSI
PSI-5.0-L16PSI-5-L13PSI-5-L11.5PSI-5.-L10PSI-5-L8Cat. No.
16 mm13 mm11.5 mm10 mm8 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
ø 5.0 mm
Length
ø 5.0 mm
ø 6.0 mm
Length
ø 6.0 mm
PSI-6-L13PSI-6-L11.5PSI-6-L10PSI-6-L8Cat. No.
13 mm11.5 mm10 mm8 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
Implant Procedures
Color Identification - drills
RED2.80mm
BLUE3.20mm
GREEN3.65mm
BLACK4.20mm
BROWN5.20mm
11
ø3.75mm ø4.2mm ø5mm ø6mm
DR 5028drill -2.80
DR 5028drill -2.80
DR 5028drill -2.80
DR 5028drill -2.80
DR 5032drill -3.20
DR 5032drill -3.20
DR 5032drill -3.20
DR 5032drill -3.20
DR 50365drill-3.65
DR 50365drill-3.65
DR 50365drill-3.65
DR 5042drill-4.2
DR 5042drill-4.2
DR 5048drill-5.2
drill pointMD 100
drill-1.20DR 0020
To be usedat thebeginingof eachprocedure
PSI -BONE TYPE ,PCI -BONE TYPE
Product IdentificationNAME DIAMETER LENGTH
PCI - 3.75 - L8
Color Identification - implants
RED3.30mm
BLUE3.75mm
GREEN4.20mm
BLACK5.00mm
BROWN6.00mm
Implant System - PCI
The Nova PCI implant is a straight wall 2.5 mm internal hex implant (standard) for both two-stage and single stage procedures. This design has a larger surface area that increases the bone to implant contact, resulting in more surface area for bone-cell attachment and interaction with the osteoblasts .
The Nova PCI implant is self drilling, with a unique wide threads design, with tapered threads on the apical part for self tapping. It can be used with all bone types, but is specially recommended for bone type 1.
All our implants can be ordered with the regular SLA surface treatment or the new RBM more advanced surface treatment.
12
Implant System - PCI
PCI-3.3-L16PCI-3.3-L13PCI-3.3-L11.5PCI-3.3-L10PCI-3.3-L8Cat. No.
16 mm13 mm11.5 mm10 mm8 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
ø 3.3 mmø 3.3 mm
ø 3.75 mmø 3.75 mm
ø 4.2 mmø 4.2 mm
PCI-3.75-L16PCI-3.75-L13PCI-3.75-L11.5PCI-3.75-L10PCI-3.75-L8Cat. No.
16 mm13 mm11.5 mm10 mm8 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
PCI-4.2-L16PCI-4.2-L13PCI-4.2-L11.5PCI-4.2-L10PCI-4.2-L8Cat. No.
16 mm13 mm11.5 mm10 mm8 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
Length
Length
Length
13
Implant System - PCI
PCI-5-L16PCI-5-L13PCI-5-L11.5PCI-5-L10PCI-5-L8Cat. No.
16 mm13 mm11.5 mm10 mm8 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
ø 5.0 mmø 5.0 mm
ø 6.0 mmø 6.0 mm
PCI-6-L13PCI-6-L11.5PCI-6-L10PCI-6-L8Cat. No.
13 mm11.5 mm10 mm8 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
Implant Procedures
Color Identification - drills
RED2.80mm
BLUE3.20mm
GREEN3.65mm
BLACK4.20mm
BROWN5.20mm
Length
Length
14
ø3.3 mm ø3.75 mm ø4.2 mm ø5 mm ø6 mm
DR 5028drill -2.80
DR 5028drill -2.80
DR 5028drill -2.80
DR 5028drill -2.80
DR 5032drill -3.20
DR 5032drill -3.20
DR 5032drill -3.20
DR 50365drill-3.65
DR 50365drill-3.65
DR 5042drill-4.2
DR 5048drill-5.2
drill pointMD 100
drill-1.20DR 0020
To be usedat thebeginingof eachprocedure
DR 5028drill -2.80
DR 5032drill -3.20
DR 50365drill-3.65
DR 5042drill-4.2
PSI -BONE TYPE ,PCI -BONE TYPE
DV2.8-L15DV2.8-L13DV-2.8-L11.5DV-2.8-L10Cat. No.
15 mm13 mm11.5 mm10 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
DV-3.3-L15DV-3.3-L13DV-3.3-L11.5DV-3.3-L10Cat. No.
15 mm13 mm11.5 mm10 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
One Stage System - DVA one piece implant and abutment (one stage) is available in 2.8 mm, 3.3mm, 3.6mm and 4.2mm diameters. The Nova one stage system is suitable for cases of narrow ridges or closed spaces between the teeth. It can also be used for immediate loading in all types of bone. All our implants can be ordered with the regular SLA surface treatment or the new RBM more advanced surface treatment. Both are conductive to bone. The transgingival neck with titanium oxide coating is placed at bone level.
Placement: Make a pilot drilling (2mm) and using the plastic mount and Nova driver (2.1 mm) to place the implant. The abutment, if required, can support the provisional prosthesis.
Impression: Use the plastic impression copying and the Nova analog.
Length
ø 2.8 mmø 2.8 mm
ø 3.30 mmø 3.3 mm
Length
RED3.30mm
Product IdentificationNAME DIAMETER LENGTH
DV - 2.8 - L13Color Identification - implants
YELLOW2.80mm
BLUE3.60mm
GREEN4.20mm
15
RED2.80mm
BLUE3.20mm
GREEN3.65mm
ø 3.6 mm
ø 4.2 mm
DV-3.6-L15DV3.6-L13DV-3.6-L11.5DV-3.6-L10Cat. No.
15 mm13 mm11.5 mm10 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
DV-4.2-L15DV-4.2-L13DV-4.2-L11.5DV-4.2-L10Cat. No.
15 mm13 mm11.5 mm10 mmLength
SLA / RBMSLA / RBMSLA / RBMSLA / RBMSurface Treatment
Implant Procedures Color Identification - drills
WHITE1.20mm
YELLOW2.50mm
Length
ø 3.6 mm
ø 4.2 mm
Length
One Stage System - DV
16
ø2.8 mm ø3.3 mm ø3.65 mm
drillNDI 2.5O
drill pointMD 100
drill-1.20DR 0020
To be usedat thebeginingof eachprocedure
drillNDI 2.5O
drillNDI 2.8O
drillNDI 2.5O
drillNDI 2.8O
ø4.2 mm
drillNDI 2.5O
drillNDI 2.8O
drillNDI 3.2O
drillNDI 3.2O
MOI-1.2-L11.5MOI-1.2-L10MOI-1.2-L8MOI-1.2-L6Cat. No.
11.5 mm10 mm8 mm6 mmLength
MOI-1.5-L11.5MOI-1.5-L10MOI-1.5-L8MOI-1.5-L6Cat. No.
11.5 mm10 mm8 mm6 mmLength
Orthodontic Anchor Screw
The Nova MOI Orthodontic anchor screws are used as an anchor system for improving anchorage efficiency during the orthodontic treatment. The Nova MOI is self Tapping for quick and easy use. Due to its temporary function the surface of the titanium is not treated by sand blasting/acid-etch.
Length
ø 1.20 mmø 1.2 mm
ø 1.50 mmø 1.5 mm
Length
17
Orthodontic Anchor Screw
MOI-2-L11.5MOI-2-L10MOI-2-L8MOI-2-L6Cat. No.
11.5 mm10 mm8 mm6 mmLength
Length
ø 2.0 mmø 2.0 mm
MOI-2.5-L11.5MOI-2.5-L10MOI-2.5-L8MOI-2.5-L6Cat. No.
11.5 mm10 mm8 mm6 mmLength
Length
ø 2.5 mmø 2.5 mm
18
HC-4070HC-4060HC-4050HC-4040HC-4030HC-4020Cat. No.
7 mm6 mm5 mm4 mm3 mm2 mmCollar
13 mm12 mm11 mm10 mm9 mm8 mmLength
3.75 mm3.75 mm3.75 mm3.75 mm3.75 mm3.75 mmPlatform
Healing CapsThe healing cap is used as a covering for the implant to prevent bone and tissue growth over the implant during osseointegration. The healing caps are taller than cover caps, and usually remain in place for about 3-6 months to allow the gum tissue to form around the shape of the cap. Healing caps also help to keep the gum tissue pushed back so that a crown or abutment can be easily fitted.
ø 4.70 mmø 4.7 mm
Length
Standard
Collar
HC-3070HC-3060HC-3050HC-4040HC-3030HC-3020Cat. No.
7 mm6 mm5 mm4 mm3 mm2 mmCollar
13 mm12 mm11 mm10 mm9 mm8 mmLength
3.75 mm3.75 mm3.75 mm3.75 mm3.75 mm3.75 mmPlatform
ø 3.75 mmø 3.75 mm
Length
Narrow
Collar
ø 4.76 mmø 4.76 mm
HCW-6060HCW-6050HCW-6040HCW-6030Cat. No.
6 mm5 mm4 mm3 mmCollar
12 mm11 mm10 mm9 mmLength
3.75 mm3.75 mm3.75 mm3.75 mmPlatform
ø 6.0 mmø 6.0 mm
Length
Wide
Collar
19
ø 4.7 mm
Premium Healing Caps
PMI 5107PMI 5106PMI 5105PMI 5104PMI 5103PMI 5102Cat. No.
7 mm6 mm5 mm4 mm3 mm2 mmCollar
13 mm12 mm11 mm10 mm9 mm8 mmLength
TI4V6AL-ELITI4V6AL-ELITI4V6AL-ELITI4V6AL-ELITI4V6AL-ELITI4V6AL-ELIMaterial
PMI 5007PMI 5006PMI 5005PMI 5004PMI 5003PMI 5002Cat. No.
7 mm6 mm5 mm4 mm3 mm2 mmCollar
13 mm12 mm11 mm10 mm9 mm8 mmLength
TI4V6AL-ELITI4V6AL-ELITI4V6AL-ELITI4V6AL-ELITI4V6AL-ELITI4V6AL-ELIMaterial
ø 3.75 mm
ø 4.70 mm
Length
PREMIUM
PREMIUM
Collar
Standard
Narrowø 3.75 mm
Length
Collar
PMI 5206PMI 5205PMI 5204PMI 5203Cat. No.
6 mm5 mm4 mm3 mmCollar
12 mm11 mm10 mm9 mmLength
TI4V6AL-ELITI4V6AL-ELITI4V6AL-ELITI4V6AL-ELIMaterial
ø 6.0 mm
PREMIUM Wideø 6.0 mm
Length
Collar
20
ST-1109Cat. No.
9 mmLength
3.75 mmPlatform
Prosthetic Standard Abutments
ø 4.76 mmø 4.76 mm
Length
Straight
Long
Nova manufactures top quality prosthetic abutments.Use with the SRR 9.4 mm standard screw and the standard a 1.25mm hex driver.
ST-1113Cat. No.
13 mmLength
3.75 mmPlatform
ø 4.76 mmø 4.76 mm
Length
STN-3811Cat. No.
11 mmLength
3.80 mmPlatform
ø 3.80 mmø 3.80 mm
Length
Narrow
Where standard crown and bridge techniques are desired, use the Nova Narrow Abutment with single-unit restorations. Nova Narrow Abutments should be used when the interdental space is limited and is compatible with the internal conical connection.
21
STA-4714STA-4713STA-4712STA-4710Cat. No.
12 mm11 mm10 mm9 mmLength
4 mm3 mm2 mm1 mmShoulder
3.75 mm3.75 mm3.75 mm3.75 mmPlatform
ø 4.76 mmø 4.76 mm
Length
Shoulder
with Shoulder
Prosthetic Standard Abutments
SLM-3813SLM-3812SLM-3810Cat. No.
3 mm2 mm1 mmPlatformHeight
11 mm10 mm9 mmLength
3.75 mm3.75 mm3.75 mmPlatform
ø 4.76 mmø 4.76 mm
Length
Anatomic Straight
Nova manufactures top quality prosthetic abutments.Use with the SRR 9.4 mm standard screw and the standard a 1.25mm hex driver.
PlatformHeight
SCM-3030SCM-3020SCM-3010Cat. No.
3 mm2 mm1 mmPlatformHeight
11 mm10 mm9 mmLength
3.75 mm3.75 mm3.75 mmPlatform
ø 4.76 mmø 4.76 mm
Length
Anatomic
Esthetic Abutments are pre-milled from titanium and are designed with scalloped margins that profile natural soft tissue contours. They are used where standard crown and bridge techniques are desired, with single and multiple-unit restorations. Esthetic Abutments are available with various collar heights based on implant platform and system.
NEW
22
PlatformHeight
Prosthetic Angulated 15˚ Abutments
ANG-1315-30ANG-1215-20ANG-1115-10Cat. No.
15˚15˚15˚Angle
3.00 mm2.00 mm1.00 mmPlatformHeight
11 mm10 mm9 mmLength
3.75 mm3.75 mm3.75 mmPlatform
ø 4.76 mmø 4.76 mm
Length
Anatomic 15˚
ASM-1315ASM-1115Cat. No.
15˚15˚Angle
13 mm9 mmLength
3.75 mm3.75 mmPlatform
ANS-1115Cat. No.
15˚Angle
9 mmLength
3.75 mmPlatform
ø 4.76 mmø 4.76 mm
Length
Narrow 15˚ø 3.80 mmø 3.80 mm
Length
Standard 15˚
Nova manufactures top quality prosthetic abutments.Use with the SRR 8.3 mm standard screw and the standard a 1.25mm hex driver.
Nova manufactures top quality prosthetic abutments.Use with the SRR 7.8 mm standard screw and the standard a 1.25mm hex driver.
23
PlatformHeight
Prosthetic Angulated 25˚ Abutments
ø 3.8 mm
ASM-1325ASM-1125Cat. No.
25˚25˚Angle
13 mm9 mmLength
3.75 mm3.75 mmPlatform
ø 4.76 mmø 4.76 mm
Length
Standard 25˚
ANS-1215Cat. No.
25˚Angle
9 mmLength
3.75 mmPlatform
ø 3.80 mm
Length
Narrow 25˚
ANG-1325-30ANG-1225-20ANG-1125-10Cat. No.
25˚25˚25˚Angle
3.00 mm2.00 mm1.00 mmPlatformHeight
11 mm10 mm9 mmLength
3.75 mm3.75 mm3.75 mmPlatform
ø 4.76 mmø 4.76 mm
Length
Anatomic 25˚
Nova manufactures top quality prosthetic abutments.Use with the SRR 7.8 mm standard screw and the standard a 1.25mm hex driver.
Nova manufactures top quality prosthetic abutments.Use with the SRR 8.3 mm standard screw and the standard a 1.25mm hex driver. 24
PlatformHeight
Esthetic Abutments are pre-milled from titanium and are designed with scalloped margins that profile natural soft tissue contours. They are used where standard crown and bridge techniques are required, with single and multiple-unit restorations.Esthetic Abutments are available with various collar heights based on implant platform and system.
ANT-1315-30ANT-1215-20ANT-1115-10Cat. No.
15˚15˚15˚Angle
3 mm2 mm1 mmPlatformHeight
11 mm10 mm9 mmLength
3.75 mm3.75 mm3.75 mmPlatform
ø 4.76 mmø 4.76 mm
Length
Anatomic 15˚
Nova manufactures top quality prosthetic abutments.Use with the SRR 8.3 mm standard screw and the standard a 1.25mm hex driver.
Prosthetic Angulated 15˚ and 25˚ Abutments
NEW
ANT-1325-30ANT-1225-20ANT-1125-10Cat. No.
25˚25˚25˚Angle
3 mm2 mm1 mmPlatformHeight
13 mm12 mm11 mmLength
3.75 mm3.75 mm3.75 mmPlatform
ø 4.76 mmø 4.76 mm
Length
Anatomic 25˚
25
NEW
PlatformHeight
PlatformHeight
Prosthetic Angulated 35˚ and 45˚ Abutments
ø 4.76 mm
ø 4.76 mm
ASM-1135Cat. No.
35˚Angle
11 mmLength
3.75 mmPlatform
ø 4.76 mm
Length
35˚
ASM-1145Cat. No.
45˚Angle
11 mmLength
3.75 mmPlatform
45˚ø 4.76 mm
Length
Nova manufactures top quality prosthetic abutments.Use with the SRR 8.3 mm standard screw and the standard a 1.25mm hex driver. 26
Ball Attachments
BAT-0060BAT-0050BAT-0040BAT-0030BAT-0020BAT-0010Cat. No.
6.00 mm5.00 mm4.00 mm3.00 mm2.00 mm1.00 mmPlatformHeight
13 mm12 mm11 mm10 mm9 mm8 mmLength
3.75 mm3.75 mm3.75 mm3.75 mm3.75 mm3.75 mmPlatform
SIH 0003SIS 0002SIL 0001HUS - 0000Cat. No.
CapCapCapBall CoverPlacement
SiliconeSiliconeSiliconeMetalMaterial
HardSoftStandardFinish
ø 4.00 mmø 4.00 mm
Length
Standard
Covers and Caps
The titanium Nova Ball Attachment provides firm retention and stabilization of the overdenture when it is used with tissue-supported implant-retained overdentures.The titanium Nova Ball Attachment is compatible with internal hex.
27
ø 4.70 mm
ø 4.76 mm
ø 4.76 mm
TRS-0010Cat. No.
10 mmLength
STAINLESS STEELMaterial
TPC-0000Cat. No.
8 mmLength
PLASTICMaterial
TMC-0930TMC-0910Cat. No.
3 mm1 mmHeight
9 mm9 mmLength
TI4V6AL - ELITI4V6AL - ELIMaterial
Impression Copings
ø 4.70 mm
ø 4.76 mm
ø 4.76 mm
Length
Length
Length
Hight
Closed TrayTRANSFER PICK-UP
Closed TrayTRANSFER PLASTIC CUP
Closed TrayTRANSFER
28
ø 4.70 mm
Impression Copings
SCR-8000Cat. No.
STAINLESS STEELMaterial
TRO-1310TRO-1309Cat. No.
13 mm9 mmLength
STAINLESS STEELSTAINLESS STEELMaterial
ø 4.70 mm
Length
Open TrayIMPRESSION COPING
TRANSFER SCREW
• FitsallNovaAbutments
• Universal1.25mmHexDriver
ABUTMENT SCREWS
SRR -9.4SRR -8.3SRR -7.8Cat. No.
9.4 mm8.3 mm7.8 mmHeight
30 Ncm30 Ncm30 NcmFinal Torque
TI4V6AL - ELITI4V6AL - ELITI4V6AL - ELIMaterial
Straight&UCLA
Abutments
AngulatedAbutments
AngulatedAbutments
Packagedwith
Length
29
ø 4.50 mm
ø 4.50 mm
SPW-1025SPW-1015SPW-1005Cat. No.
2.50 mm1.50 mm0.50 mmAbutment
8 mm7 mm6 mmLength
PTS-4512Cat. No.
12 mmLength
SRS-5020Cat. No.
6.5 mmLength
Esthetic Abutments
ø 4.50 mm
ø 4.50 mm
LengthHight
Length
Length
ComponentsCONNECTIONS
PLASTIC SLEEVE
CONNECTION SCREW
30
ø 4.50 mm
ø 6.00 mm
Abutment Sleeves
PIS-0013PIS-0012Cat. No.
√-Hex
12 mm12 mmLength
PLASTIC - REDPLASTIC - WHITEMaterial
PIW-6013PIW-6012Cat. No.
√-Hex
12 mm12 mmLength
PLASTIC - WHITEPLASTIC - WHITEMaterial
ø 4.50 mm
ø 6.00 mm
Length
Length
Delrin Hex And Non-HexPlastic Sleeve
Delrin WIDE Hex and Non-HexPlastic Sleeve
ø 6.00 mm
PTA-1312Cat. No.
√Hex
12 mmLength
PLASTIC & TITANIUMMaterial
ø 6.00 mm
Length
Custom Titanium Castable Abutments(UCLA)
31
Custom Titanium Castable Abutments(UCLA)
ø 4.76 mm
ø 4.76 mm
PAN-1315-30PAN-1215-20PAN-1115-10Cat. No.
15˚15˚15˚Angle
3.00 mm2.00 mm1.00 mmPlatformHeight
11 mm10 mm9 mmLength
3.75 mm3.75 mm3.75 mmPlatform
PAN-1225-20PAN-1125-10Cat. No.
25˚25˚Angle
2.00 mm1.00 mmPlatformHeight
10 mm9 mmLength
3.75 mm3.75 mmPlatform
Plastic Anatomic Abutments
ø 4.76 mm
ø 4.76 mm
Length
Length
Angulated 15˚
Angulated 25˚
Nova manufactures top quality prosthetic abutments.Use with the SRR 8.3 mm standard screw and the standard a 1.25mm hex driver. 32
Zirconium Abutments
ø 4.76 mm
ZRX-1111ZRX-1110ZRX-0910Cat. No.
3 mm2 mm1 mmHeight
11 mm10 mm9 mmLength
3.75 mm3.75 mm3.75 mmPlatform
ZRX-ZRX-1315-30ZRX-1215-20ZRX-1115-10Cat. No.
15˚15˚15˚Angle
3 mm2 mm1 mmHeight
11 mm10 mm9 mmLength
3.75 mm3.75 mm3.75 mmPlatform
ZRX-1125-20ZRX-1125-10Cat. No.
25˚25˚Angle
2 mm1 mmHeight
10 mm9 mmLength
3.75 mm3.75 mmPlatform
ø 4.76 mmø 4.76 mm
Length
Height
Height
Standard
ø 4.76 mm
Length
Angulated 15˚
ø 4.76 mmø 4.76 mm
Length
Angulated 25˚
Hight
Nova manufactures top quality prosthetic abutments.Use with the SRR 9.4 mm standard screw and the standard a 1.25mm hex driver.
Nova manufactures top quality prosthetic abutments.Use with the SRR 9.4 mm standard screw and the standard a 1.25mm hex driver.
33
ø 3.30 mm
ø 4.00 mm
ADV-3017Cat. No.
17 mmLength
STAINLESS STEELMaterial
ANL-0002ANL-0001Cat. No.
12 mm12 mmLength
TI4V6AL - ELISTAINLESS STEELMaterial
Implant Analogs
ø 3.30 mm
ø 4.00 mm
Length
Length
Suitable for use with the One Stage Implants and Abutments System
Suitable for use with the PSI Implants
34
Drills and Countersinks
ø 1.9 mmRound Bur
Pilot Drill
Drills
ø 2.0 mm
ø 2.8 mm
ø 3.2 mm
ø 3.8 mm
ø 4.2 mm
ø 4.8 mm
ø 3.8 - 4.2 mmCountersink
Trephine Burr
Long
Conical
ø 5 - 6 mm
ø 5.2 mm
Short
without irrigation
35
DR 5019
DR 5020
DR 5028
DR 5032
DR 5038
DR 5042
DR 5048
DR 3842
DR 5060DR 5052
TDC 25X37 L 16
TDC 27X45 L 16
TDC 18X24 L 16
TDC 31X55 L 16
TB 4.0X5.0 L 16
TDS 420 L10
TDS 280 L10
TDS 320 L20
TDL 250 L20
TB 2.0X3.0 L 16
TB 3.0X4.0 L 16
Hand Ratchet
AR 2060
DP 3040
Hand Driver Hex
Hand Driver for DVNova One StageImplants
Measure for Drill Depth
Cover Screw
Motor Mount Hex1.25 L22 mm / 1.25 L28 mm
Motor Mount Hex2.42 L20 mm / 2.42 L28 mm
HR 2050
KT 2510 / KT 2515
CS 4040
HD 2507 1.25 L7 mmHD 2510 1.25 L10 mmHD 2515 1.25 L15 mm
HD 4507 2.42 L7 mmHD 4510 2.42 L10 mmHD 4515 2.42 L15 mm
MG 2522 / MG 2528
MG 4220 / MG 4228
Hex Drive
1.25 L10 mm & 1.25 L15 mm
36
Implant Tools
Implant Tools
Surgical Screw Driver Hex 6.35 mm
Laboratory Screw Driver Hex 1.25 mm
AR 2040
LABK 1010
RC 2030
Ratchet
KITCAT No. PRODUCTDR-5019 Round Bur Ø 1.9 without irrigationDR-5020 Pilot Drill Ø =2.0mmDR-5028 Drill Ø =2.8mmDR-5032 Drill Ø =3.2mmDR-5038 Drill Ø =3.8mmDR-5042 Drill Ø =4.2mmDR-5048 Drill Ø =4.8mm
GP-1020 Guide Pin 10mm x 2GP-1320 Guide Pin 13mm x 2HD-2507 Hex Driver 1.25 L 7mmHD-2510 Hex Driver 1.25 L10mmHD-4507 Hex Driver 2.42 L 7mmHD-4515 Hex Driver 2.42 L15mmMG-2422 Motor Mount 2.42 Hex L28mmMG-2522 Motor Mount 1.25 Hex L22mmMG-2528 Motor Mount 2.42 Hex L20mmRC-2030 RatchetDrill ExtensionMC-0001 Metal Container
37
Packaging
All Nova implants come in a sterile double pack. The transparent outer blister contains a vial that holds the pre-mounted implant and cover screw.
The implant type, diameter and length is displayed on a sticker that is also placed within the blister pack.
Medical SymbolsSTERILE R
2!
LOT
Sterlized using irradation.Sterility guaranteed if pack unopened or undamaged.
For single use only.
Reference to the hazards in the operating instructions.
Use by YYYY-MM
Lot number
Catalogue number
CE certification marking
CAT
Expiry date
38
Step by Step
Before beginning the procedure make sure surgical gloves are worn.Peel back the blister cover to reveal the vial. Remove vial from pack as shown below.
1. Removing the implant from the vial using the hand ratchet (RC 2030)- Gently loosen the seal by rotating it with the use of the hand ratchet.-Slowly pull out the implant from the vial.
2. Removing the implant from the vial using a wrench (AR 2040)- Connect the wrench to the seal.- Gently loosen the seal by rotating it with the use of the wrench.- Slowly pull the implant out of the vial.
3. Removing the implant from the vial using a surgical screwdriver (KT 2510 / 2515)- Connect the surgical screwdriver to the seal.- Gently loosen the seal by rotating it with the use of the surgical screwdriver.- Slowly pull the implant out of the vial.
Blister Pack
3 ways to remove the implant from the vial
39
Procedures
Implant & Healing Cap Abutment Impression Transfer Model Casting Transfer & Abutment
GIPS
Abutment Preparation Final Restoration
Ball System ElementsImplants & Healing Cap Abutment OR Direct Impression Transfer
Final RestorationImplant Level Impression
GIPS
GIPS
GIPS
40
Description: Nova Implants are manufactured from bio compatible titanium and titanium alloy and abutments from titanium or titanium alloy. Nova Implants and Abutments include various surface treatments and coatings. Other restorative components are manufactured with titanium or titanium alloy, stainless steel and a variety of polymers.For specific product description refer to individual product labels.Indications for Use: Nova Implants are intended for surgical placement in the upper or lower jaw to provide a means for prosthetic attachment in single tooth restorations and in partially or fully edentulous spans with multiple single teeth utilizing delayed or immediate loading, or as a terminal or intermediary abutment for fixed or removable bridgework, and to retain over dentures.Nova Implants are intended for immediate function on single tooth and/or multiple tooth applications when good primary stability is achieved, with appropriate occlusal loading, in order to restore chewing function.Additional Indications: Nova Dental Abutments and Over denture Bars are intended for use as an accessory to end osseous dental implants to support a prosthetic device in a partially or edentulous patient. These are intended for use to support single and multiple tooth prostheses, in the mandible or maxilla. The prostheses can be screw or cement retained to the abutment.PEEK Abutment Posts and Temporary Cylinders are intended for use as an accessory to end osseous dental implants to support a prosthetic device in a partially or fully edentulous patient. These are intended for use to support single and multiple unit prostheses in the mandible or maxilla for up to 180 days during end osseous and gingival healing, and are for non occlusal loading of single and multiple unit provision al restorations. The prostheses can be screw and/or cement retained to the abutment. These Temporary Posts and Cylinders require a minimum inter arch space of 6mm and a maximum angulation of 15°. These also allow for occlusal loading of single and multiple unit restorations of integrated implants for guided soft tissue healing. The Quick Bridge Provisional Components are intended to be mated with Nova Conical Abutments for use as an accessory to end osseous dental implants to support a prosthetic device in a partially or fully edentulous patient.
Contraindications: Placement of dental implants may be precluded by patient conditions that are contraindications for surgery. Nova Implants should not be placed in patients where the remaining jaw bone is too diminished to provide adequate implant stability. Cardiac conditions involving the risk of endocarditis, coronary insufficiency blood dyscrasias, cardiovascular disorders, patients on anticoagulant Rx A.I.D.S., cancers and chemotherapeutic treatments, corticosteroids treatment radiotherapy of the cervico-facial region osteoporosis, uncontrolled or insulin-dependant diabetes pregnancy, endocrine disorders.Possible contraindicationsPoor oral hygiene, bruxism alcoholism, smoking, drug abuse psychological problems aggressive behavior. Temporary contraindications Systemic infection, local oral or respiratory infection.Local contraindicationsInsufficient alveolar bone width and height to ensure the encompassing of the implant with at least one millimeter of bone Infections, cysts, tumors, periodontal disease, prostodontic problemsStorage and Handling: Devices should be stored at room temperature. Refer to individual product labels and the Surgical Manual for special storage or handling conditions.
Warnings: Excessive bone loss or breakage of a dental implant or restorative device may occur when an implant or abutment is loaded beyond its functional capability. Physiological and anatomic conditions may negatively affect the performance of dental implants. The following should be taken into consideration when placing dental implants:- Poor bone quality-- Poor oral hygiene - Medical conditions such as blood disorders or uncontrolled hormonal conditionsIt is recommended that small diameter implants not be restored with angled abutments in the molar region.Mishandling of small components inside the patients mouth carries a risk of aspiration and/or swallowing.Forcing the implant into the osteotomy deeper than the depth established by the drills can result in: stripping the driver hex interface inside the implant, stripping the driver, cold welding of the mount-driver interface to the implant, or stripping the walls of the osteotomy that may prevent an effective initial implant fixation.
Clinical data have demonstrated enhanced performance of OSSEOTITE Implants as compared to other Nova Implants in patients with poor quality bone.
Precautions: For safe and effective use of Nova Implants, abutments and other surgical and restorative dental accessories, these products or devices should only be used by trained professionals. The surgical and restorative techniques required to properly utilize these devices are highly specialized and complex procedures. Improper technique can lead to implant failure, loss of supporting bone, restoration fracture, screw loosening and aspiration.Sterility: All dental implants and some abutments are supplied sterile and are sterilized by an appropriate validated method. Refer to individual product labels for sterilization information; all sterile products are labeled “STERILE”. All products sold sterile are for single use before the expiration date printed on the product label. Do not use sterile products if the packaging has been damaged or previously opened. Do not re-sterilize or autoclave except where instructions to do so are provided on the product label, in the Surgical Manual, in the Restorative Manual or in any additional marketing literature for that product. Products provided non-sterile must be cleaned and sterilized according to the directions found in Surgical Manuals prior to use.
Procedural Precautions, Surgery:For a detailed explanation of the procedural precautions refer to the Surgical Manual. During the planning phase, it is important to determine the vertical dimension, the actual space available between the alveolar crest and the opposing dentition, in order to confirm that the available space will accommodate the proposed abutment and the final crown restoration. This information varies with each patient and abutment; therefore it should be carefully evaluated before placing any dental implant. The final prosthesis should be designed prior to the placement of the dental implant. Utilize continuous irrigation with a cool, sterile irrigating solution to avoid excessive damage to the surrounding tissue and to prevent compromising osseo integration. This is mandatory during gall procedures. Avoid excessive pressure during preparation of the bone site. As the drilling speed varies based on the instrument and the surgical procedure, recommendations for speed can be found in the Surgical Manual. Only sharp instruments of the highest quality should be used for any surgical procedure involving bone. Minimizing trauma to the bone and surrounding tissue enhances the potential for successful osseo integration. In order to eliminate contaminants and other sources of infection, all non-sterile devices should be cleaned and/or sterilized prior to use, per the instructions on the individual product labels.
Procedural Precautions, Restoration: The healing period varies depending on the quality of the bone at the implantation site, the tissue response to the implanted device and the surgeon’s evaluation of the patient’s bone density at the time of the surgical procedure. Excessive force applied to the dental implant should be avoided during the healing period. Proper occlusion should be evaluated on the implant restoration to avoid excessive force.
Potential Adverse Events:Potential adverse events associated with the use of dental implants may include:- Failure to integrate- Loss of integration- Dehiscence requiring bone grafting- Perforation of the maxillary sinus, inferior border, lingual plate, labial plate, inferior alveolar canal, gingiva- Infection as reported by: abscess, fistula, suppuration, inflammation, radio lucency- Persistent pain, numbness, paresthesia- Hyperplasia- Excessive bone loss requiring intervention- Implant breakage or fracture- Systemic infection - Nerve injury.
Techniques:- Determine local anatomy with the use of local X-rays and CT. etc.- Planning the site, the technique and the dimensions of the implant to be used.- Careful management and high precision is recommended.
Caution: U.S. Federal Law restricts this device to sale by or on the order of a licensed dentist or physician.
User Instructions
41
P.O.B. 2318, Kiryat Ono, 55122, IsraelTel: +972 (0)54 752 8166. Telefax: +972 (0) 77 352 8166
Website: nova-implants.com ISO 9001:2008ISO 13485:2003