the most powerful air conditioner · 2018-01-17 · 10m 18m 20m 25m* powerful mode is more...
TRANSCRIPT
A948
8 / I
ndia
Cat
alog
ue J
anua
ry 2
018
THE MOST POWERFUL AIR CONDITIONER
2017
ETA General Private Limited
CORPORATE OFFICE:
ETA Star House, No.71 / 63, 3rd Floor, Sterling Road, Nungambakkam, Chennai 600 034 | Ph: 044 43402345 | Fax: 044 43402343
Web: www.generalindia.com | e-mail: [email protected]
REGISTERED OFFICE: R.S. Nos. 79 to 81, Kalitheerthalkuppam, Mannadipet, Puducherry 605 107, Ph. 044 43402345. CIN:U29308PY1999PTC001499.
REGIONAL OFFICE: Delhi: 011 43127777 | Mumbai: 022 42455300 / 02 | Kolkata: 033 40060794.
SERVICE: SOUTH: Bengaluru: 080 4092 6531 / 4092 6538, 97413 37111 | Bhubaneswar: 94372 53566 | Cochin: 0484 4011623, 90482 20228
Chennai/Puducherry: 90038 90377 | Coimbatore & Madurai: 98422 60111 | Hyderabad: 040 66103530 / 3531, 99633 44277 | Vijayawada: 0866 6460278 /
3074029, 99493 68627 | NORTH: Chandigarh: 0172 5087288, 98151 92456 | Delhi: 011 43127777, 99716 66755 | Ghaziabad: 0120 4291121, 88008 98435
Jaipur: 0141 4012684, 99280 55955 | Jamshedpur: 88722 19700 / 94315 67563 | Lucknow (U.P.): 0522 4006879, 77060 04008 | Ludhiana: 96464 85500
Mumbai: 022 42455300 / 5302, 89760 38396 | WEST: Ahmedabad/Surat/Gandhinagar: 40058991, 80000 79746 | Nagpur: 98817 46855 | Pune/Goa:
98231 90967 | Indore: 99260 01437 | MP: Bhopal: 99934 43691 | EAST: Patna: 93049 15264 | Raipur: 75818 10189 | Kolkata: 033 40060794, 83350 41629.
BRANCH OFFICE: SOUTH: Bengaluru: 080 40926531 / 6538 | Kochi: 0484 4011623, 98478 16888 | North Kerala: 99950 08876 South Kerala: 93873 15113
Central Kerala: 86060 07879, 83010 84302 | Coimbatore: 0422 2220221, 97909 18207 | Madurai: 99655 84673 | Trichy: 98424 42308
Puducherry: 96558 81357 | Hyderabad: 040 66103530 / 3531, 40340011 | Vijayawada: 0866 6460278, 3074029 | NORTH: Greater Punjab (Himachal Pradesh,
J&K, Haryana, Chandigarh & Punjab): 0172 5087288 / 7289 / 7290 | J&K: 98889 96580 | Chandigarh: 76969 10681 | Haryana (Karnal): 89505 69826
Lucknow: 0522 4006879 | Ghaziabad: 0120 4291121 | Jaipur: 0141 4012684 | Ludhiana: 82838 86960 | Jalandhar: 95305 11442
WEST: Ahmedabad: 079 27467991 / 2891, 40058991 | Goa: 98221 26401 | Indore: 99777 00830 | Nagpur: 98238 67510 Pune: 93257 16812, 93257 16807,
98903 90427 | Raipur: 81090 19220 | Bhopal: 99771 21274 | Surat: 0261 3924770, 98258 76503 | EAST: Patna: 88774 77555 | Ranchi: 97090 79555
Orissa: 0674 2572038, 78730 78714.
We have not authorised any E-commerce site to sell our products. To buy General air conditioners online, please visit our e-Shop at www.generalindia.com
Scan this QR code on your deviceto visit our website
ALL INDIA CUSTOMER CARE
1860 2081 007 [email protected]
AUTHORISED DEALERS ONLY
1860 258 3133 [email protected]
A9488 ETA General Cat 2018 Pg 28 01 /A4 / 10 01 18 / raj
25m*20m10m 18m
Powerful mode is more power-up!
2
3
4
1
Super High
High
Med
Low
Quiet
Powerful*
*One touch powerful cooling mode: Continuous operation for 30 minutes at maximum air volume
5 speed + Powerful cooling mode
6 Speed Fan Control
1 Large display
2 Easy to operate new square design
3 One touch Powerful cooling mode
4 Easy to use large cursor key
Powerful and beautiful! New large wall mounted Split AC!
TROPICAL INNOVATION Series
ASGA18FUTC / ASGA24FUTA / ASGA30FUTC
Luxurious & Elegant Design
Golden Ornament Dual Suction Intake Design Trimmed Edge Design
New Design
New Technology
Possible to cool every corner of a big room immediately.
1
1
2
3
Large airflow volumefrom dual suction1
Current model
NEW model (+60mm)
New long cross-flow fan2 High output DC fan motor3
• Dual Suction• Optimized Airflow Design
ASGA30FUTC 25m*ASGA24FUTA 20mASGG12JLCA 10m ASGA18FUTC 18m ASGA30FUTC ASGA30FUTC 25m25m25m25m*ASGA24FUTA 20m20m20m20mASGG12JLCAASGG12JLCA 10m10m10m10m ASGA18FUTC 18m18m18m18m
06 07
15mASGG18LFCDASGG24LFCDASGG30LFCE
ASGA18JCCASGA24JCCASGA30JCCASGA18FTTCASGA22FTTC
10 11
Performance
For Tropical Innovation Series
Handy typeremote controller
Signal Transmitter Timer ButtonRemote Control Unit Display(LCD)
Horizontal Swing Button
Horizontal
Set Button
Fan Control Button
Temp/Time Set Button
Start/Stop Button
Sleep Button
Master Control Button/
Mode Change Button
Vertical Set Button
Vertical Swing Button
Remote Control Unit Display(LCD)
Signal Transmitter
Fan Control Button
Vertical Set Button
Vertical Swing Button
All Clear Button
Set Temp. Button
Master Control Button
Coil Dry Button*
Test Run Button
For Window AC
For Split AC
Timer Button
Sleep Button
Start/Stop Button
Feature Packed Remote
*Specifications & features may vary model-wise and are subject to change without notice.
Powerful and Compact DesignThough the indoor unit is compact, it features a large, high pressure cross fan (90mm diameter) in a center mounted configuration and a Lambda Type Heat Exchanger to provide plenty of power. The extra long diffuser provides a wide outflow opening for air. This ensures a large air outflow volume over a wide area to cool or heat all areas of the room.
High Air QualityPerfect comfort is ensured by the removal of dust, odor and bacteria in the air. Intake of fresh air, and other clean air conditioning technologies always takes health into consideration. Mildew resistant filter prevents mold formation in the indoor unit.
width:20.6cm
26.2cm
82.0cmSimple and compact design fits any interior decor
High efficiency BLDC MotorDC fan motor produces high power, wide operation range, and high efficiency.
• 20% increase in motor efficiency
• 20% lesser vibration
• Lower noise
Least Derration EffectGeneral Air Conditioners are designed to perform at ambient conditions as high as 60oC. Housed in larger outdoor units, the machines carry high BTU hyper-tropical compressors with large copper heat exchangers to ensure better heat transfer.
Blue Fin Condenserfor long lifeAdoption of strong blue fin hydrophillic c o a t e d he a t excha nge r p r ov i de s protection against rust and salt damage.
Hydrophillic Film
Corrosion-resistant
Acrylic Resin
Aluminium
Anti-Corrosion Treated Fin
Enhanced protection
Large Outdoor FanLarge fan (Ф 450x130) with power ful motor at high CFM for better heat transfer.
Performance
Temperature rise prevention device (thermal protector) installed
High-output torque motor. Torque improved by increasing the thickness of the laminatedcore and improving the coil winding
High durability crankshaft with hardness improved by adding a coating
Gas leak protection and low voltage protection OLP (Over Load Protection) device installed
High durability rolling piston with hardness improved by changing the material
High durability vane.Surface hardness increased
1.Improvement of compressor drive materials for greater durability (hardness increased).2.Use of high efficiency, high torque motor.3.Complete protection functions against abnormal temperature rise and abnormal pressure rise.
Hyper Tropical Spec
Super eco-friendlyCompressor based onEco-friendly R410A refrigerant designed forhigher ambient temperature of 52°C.
Super powerful10% more capacity than old modelsunder overload condition (60°C).
Super low voltage operationOur Hyper Tropical Compressor can be operated even at a low voltage.
Super Hi-EER5-10% higher than our old model.
Super quietReduces the noise level byabout 3dB at 220V operation.
Designed & developed by Fujitsu General
High Density Multi-Path Heat ExchangerHeat exchange performance is substantially improved by the thin high-density heat exchanger and multi-path efficiency technology. High performance grooved piping with expanded heat exchanger area is used for better heat transfer.
Ø5 mm
20 mm
Refrigerant
Multi-path
Distributor
Low NoiseSqueaking sound is eliminatedby simplifying the constructionof resin parts and using softresin at parts where stressis concentrated.
Adopting soft type resin
Base and casing integrated molding
One-piece panel (Unification of parts)
Tem
pera
ture
Time
Powerful
Setting temp.
Normal mode
Cooling time in normal mode is about 20% shorter than in high mode.
Pushbutton
Powerful OperationTwenty minutes of continuous operation by maximising airflow and at maximum compressor speed allows the temperature to reach optimum levels. Rapid cooling and heating makes the room comfortable quickly.
Powerful HeatingH i g h h e a t i n g c a p a c i t y i s realized even at low outdoor temperature by mounting a large heat exchanger and large DC rotary compressor along w i t h a h i g h p e r f o r ma n c e inverter PCB.
New Hyper Tropical Rotary Compressor
Realizing high-density heat transfer tube arrangement by making the tube thin
Volume reduction of heat
exchanger: 30%
Making the tube thin:
7mm 5mm
Even temperature
Improved the heatexchanger effectiveness
mm
Hyper TropicalRotary Compressor
Hyper Tropical
~52°C
A9488 ETA General Cat 2018 Pg 10 11 - A4 / 09 01 18 / Ajay
Start / stop button
Mode Button
TEMP. (temperature) buttons
Fan buttonsPowerful cooling button
Swing buttonVertical set button
Horizontal set button
Timer buttonSleep button
Reset button
Clock adjust buttonTest run button
Remote controller display
Signal transmitter
formation in the indoor unit.
26.2cm
12 13
OFF-ON timer
From sleep to wake-up
12
6
ON 9hours
OFF2hours
9 3PM9:00 set
ON-OFF timer
From wake-up to
go to work
OFF10hours
ON 7hours
12
6
9 3
PM11:00 set
Tem
p.
Economy operation
Shift setting temp
Normal operationTime
Set temperature
Power consumption10%down
ALL DC Saves Energy Throughout the YearBy making all the motors DC, electricity loss is decreased and power consumption is substantially reduced. In addition, high-speed fan motor rotation is possible, heat exchange efficiency is increased and annual power consumption amount is saved by increasing the airflow.
More Convenient TimerYou can set a program timer ON-OFF or OFF-ON timer that’s suitable for your lifestyle (Setting time: 0.5, 1, 1.5, 2, --- 9.5, 10, 11, 12 hours)
Economy OperationEconomy operation is for energy saving. As the set temperature of the indoor unit is shifted by 1°C, the load on the outdoor unit is minimised thus saving power by 10%.
Faster Cooling and Comfort ControlInverter ACs take half the time to reach the set temperature and precise control of room temperature is also attained.
Part Load EfficiencyMore power saving can be achieved by using Inverters as they operate under part-load condition most of the time.
DC Rotary CompressorThe high efficiency DC inverter type "rotary compressor" is used for our product ranges. It has achieved higher energy efficiency compared to similar compressors by optimizing the structure inside the compressor.
Sine-wave DC Inverter ControlHigh efficiency operation is realized by using a sine wave DC inverter control.
DC Fan Motor
Inverter Control Base
DC Compressor
Wide high efficiency rangeDC rotary compressor
Starting point: Set temperature: 240C, Operation Time: 3 hours, Room Inside: 350C, Outdoor: 350C (For 12000BTU/Hr model)
Set temperature
Compressor Speed
Set temperature
Compressor Speed
TECHNOLOGYINVERTER
What is an INVERTER air conditioner ?INVERTER is an equipment that controls the electrical voltage, current and frequency of the compressor motor in an air conditioner.
An INVERTER air conditioner changes the speed of the compressor by varying the frequency of the power supply to give superior cooling, ranging from high to low.
When an INVERTER air conditioner is started, the compressor runs at high speed for quick cooling. But once the set temperature is reached, the INVERTER air conditioner enters an ‘energy saving mode’ by reducing the compressor speed. Thus, effectively reducing its power in order to save energy.
In over 90% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity. We focused on high seasonal efficiency with and all DC inverter control and high efficiency technology.
I-PAM Control Panel
I-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform. This promotes the effective use of the input power supply to attain high performance.
I-PAM Control (PAM+IPM)Inverter Control
Time
SettingTemp.
Temp.
ConventionalInverter Control
I-PAMInverter Control
Conventional Inverter
I-PAM Inverter
“I-PAM (Intelligent power module – Pulse Amplitude Modulation)”
Energy saving and quick heating only possible by I-PAM
Illustrations and graphs may differfrom actual state
Our conventional typeInverter Model
Attain your desired temperature in just1/3 of the time compared to our conventional inverter models.
I-PAM Control Model
Voltage and speed of the compressor motorTemperature of 10 cm above floor
“V-PAM (Vector – Pulse Amplitude Modulation)”
V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and ef ficiency of the compressor by vector control technology. With this technology, further miniaturization, higher efficiency and better performance is attained.
It becomes more powerful with the newly developed high efficiency compressor motor control.
High
Electricity Charge
LowSaving electricity cost
Conventional Model
New model
Electricity costremains low
PowerHigh
LowOutput increased to greater thanthat of conventional models
Higher output thanour conventionalmodels
conventional models
New model
V-PAM (Vector + I-PAM)Inverter Control
Pursuit of Seasonal EfficiencyHighHigh
COP
COP
(%)(%)Heating part loadHeating part load
2525 5050 7575 100100
Frequent operation range
Faster Cooling
InverterCircuit
CompressorSpeed
CompressorSpeed
Power
Power
MAX
WideRange
50Hz
50Hz
MIN
NarrowRange
Accumulated power consumption
Inverter Model
Conventional Model
NON-INVERTER
Set
Temp.
SetTemp.
Temp.
Tem
p.
Tem
p.
Time
Energysaving
Power Supply
Power Supply
Temp.
Tem
p.
Time
More compact thanconventional models V-PAM
A9488 ETA General Cat 2018 Pg 12 13 - A4 / 11-01-18 / raj
15
*Speci�cations, design and features are subject to change without prior notice for further development. The above models conform to energy labelling as per BEE regulation. Piping can be extended to above length for full ef�ciency with additional charge of gas and above 10mts/15 mts/20mts as per installation manual. The noise level is the value when measured in an anechoic room.
*Speci�cations, design and features are subject to change without prior notice for further development. The above models conform to Energy labelling as per BEE regulation. Piping can be extended to above length for full ef�ciency with additional charge of gas and above 10mts/15 mts/20mts as per installation manual. The noise level is the value when measured in an anechoic room.
14
Premium Wall Mounted Split Air Conditioners
TROPICAL INNOVATION SeriesHot & Cold Wall Mounted Split Air Conditioners
INVERTER
15
Hot & Cold ASGG18LFCD / ASGG24LFCD / ASGG30LFCE
15m Long-reach Air�ow Ambient Operating Range
50
40
30
20
10
0
-10
-15
Cooling46°C
-10°C-15°C
24°CHeating
TECH
NICA
L SP
ECIF
ICAT
IONS
PARAMETERS CATEGORY UNITS ASGG18LFCD ASGG24LFCD ASGG30LFCEBEE Star Rating 5 4 4Tonnage - TR 1.5 2.0 2.5
Capacity (Range)Cooling kW 5.2(0.9~6.0) 7.1(0.9~8.0) 8.0(2.9~9.0)
BTU/hr 17,700(3,100~20,500) 24,200(3,100~27,300) 27,300(9,900~30,700)
Heating kW 6.3(0.9~9.1) 8.0(0.9~10.6) 8.8(2.2~11.0)BTU/hr 21,500(3,100~31,000) 27,300(3,100~36,200) 30,000(7,500~37,600)
Moisture Removal - l/hr 2.6 2.7 3.2Indoor Airflow Volume-High Indoor m3/hr 900 1,120 1,100Indoor Airflow Distance - m 15 15 15Power Supply - V/Ph/Hz 220~240/1/50
Running Current Cooling A 6.8 9.7 10.9Heating A 7.6 9.7 10.7
Power Consumption Cooling W 1,520 2,200 2,490Heating W 1,710 2,210 2,440
ISEER Cooling W/WEER Heating W/W 3.68 3.61 3.61Indoor Unit Dimensions HxWxD
Indoor mm 320x998x238 320x998x238 320x998x238Indoor Unit Net Weight kg 14 14 14Outdoor Unit Dimensions HxWxD Outdoor mm 620x790x290 620x790x290 830x900x330
Outdoor Unit Net Weight kg 41 41 61Indoor Noise Level (Quiet) - dB(A) 26 32 33
Outdoor Noise Level Cooling dB(A) 54 54 54Heating dB(A) 54 54 54
Connection Pipe (Gas, Liquid) - inch 1/2, 1/4 5/8, 1/4 5/8, 3/8- mm 12.70, 6.35 15.88, 6.35 15.88, 9.53
Pipe Length Min~Max (Precharged)
- m 3~25(15) 3~30 3~50
Max Height Difference - m 20 20 30
Operating Temperature Cooling oC -10oC~46oC -10oC~46oC -10oC~46oCHeating oC -15oC~24oC -15oC~24oC -15oC~24oC
Refrigerant - - R410A R410A R410ACompressor - - Twin Rotary Twin Rotary Twin Rotary
Cooling ASGA18FUTC / ASGA24FUTA / ASGA30FUTC
Ambient Operating Range
50
55
60
40
30
20
10
0
Cooling52°C
21°C
Super High
High
Med
Low
Quiet
Powerful
6 Speed Fan Control25m Long-reach Air�ow25m Long-reach Air�ow
25m
15m Long-reach Air�ow
UNITS ASGG18LFCD
15m15m
Blue Fin Condenser Catechin Filter
Hyper TropicalCompressor
Hyper Tropical
~52°C
DOUBLE SWINGAUTOMATIC - 3D
COANDA AIRFLOWTECHNOLOGY25m
DUAL SUCTIONINTAKE DESIGN
QUIET OPERATIONSELFDIAGNOSIS
DOUBLE SWINGAUTOMATIC - 3D 15m COANDA AIRFLOW
TECHNOLOGYi-PAMCONTROL
QUIET OPERATIONSELFDIAGNOSIS
TECH
NICA
L SP
ECIF
ICAT
IONS
TECH
NICA
L SP
ECIF
ICAT
IONS
PARAMETERS UNITS ASGA18FUTC ASGA24FUTA ASGA30FUTC
BEE Star Rating - 3 2 3
Tonnage TR 1.5 2.0 2.5
Cooling CapacityW 5,470 7,110 8,180
BTU/hr 18,660 24,260 27,910
Moisture Removal l/hr 1.0 2.0 2.5
Indoor Airflow Volume-Powerful/Super High/High/Med/Low/Quiet
m3/hr 1400/1250/1130/1000/870/740 1500/1350/1200/1050/900/740 1630/1520/1380/1260/1130/1000
Indoor Airflow Distance m 18 20 25
Power Supply V/Ph/Hz 220~240/1/50
Running Current A 6.9 9.4 10.5
Power Consumption W 1,560 2,100 2,340
ISEER W/W
Indoor Unit Dimensions HxWxD mm 340x1150x280 340x1150x280 340x1150x280
Indoor Unit Net Weight kg 16 16 17
Outdoor Unit Dimensions HxWxD mm 650x830x320 650x830x320 914x970x370
Outdoor Unit Net Weight kg 47 52 77
Indoor Noise Level (Quiet) dB(A) 34 35 41
Outdoor Noise Level dB(A) 53 55 54
Connection Pipe (Gas, Liquid)inch 5/8, 1/4 5/8, 1/4 5/8, 3/8
mm 15.88, 6.35 15.88, 6.35 15.88, 9.53
Pipe Length Min~Max (Precharged) m 3~20(7.5) 3~20(7.5) 3~30(7.5)
Max Height Difference m 8 8 15
Max Operating Temperature oC 52oC 52oC 52oC
Refrigerant - R410A R410A R410A
Compressor - Hyper Tropical Rotary Hyper Tropical Rotary Hyper Tropical Scroll
Deodorizing Filter
- - - - - - -
A9488 ETA General Cat 2018 Pg 14 15_A4 | 09 01 18 / Ajay
16 17
Cooling ASGA18FTTC / 22FTTC
Cooling ASGG12JLCA
Cooling ASGA18JCC / 24JCC / 30JCC
Ambient Operating Range
50
55
60
40
30
20
10
0
Cooling52°C
21°C
High
Med
Low
Auto
4 Speed Fan Control15m Long-reach Air�ow 4 Speed Fan Control15m Long-reach Air�ow
Hyper TropicalRotary Compressor
*Speci�cations, design and features are subject to change without prior notice for further development. The above models conform to energy labelling as per BEE regulation. Piping can be extended to above length for full ef�ciency with additional charge of gas and above 10mts/15 mts/20mts as per installation manual. The noise level is the value when measured in an anechoic room.
Cooling
46°C
18°C
50
40
30
10
20
18
Ambient Operating Range15m Long-reach Air�ow15m Long-reach Air�ow
INVERTERWall Mounted Split Air Conditioners
HYPER TROPICAL Wall Mounted Split Air Conditioners
PARAMETERS UNITS ASGG12JLCA ASGA18JCC ASGA24JCC ASGA30JCC
BEE Star Rating 4 5 4 4
Tonnage TR 1.0 1.5 2.0 2.5
Capacity (Range)kW 3.5(0.9~3.75) 5.2(0.9~6.0) 7.1(0.9~8.0) 8.0(2.9~9.0)
BTU/hr 11,940(3,100~13,600) 17,740(3,100~20,500) 24,220(3,100~27,300) 27,300(9,900~30,700)
Moisture Removal l/hr 1.8 2.8 3.0 3.0
Indoor Air� ow Volume-High m3/hr 720 900 1,100 1,100
Indoor Air� ow Distance m 10 15 15 15
Power Supply V/Ph/Hz 220~240/1/50
Running Current A 5.1 6.6 10.8 11.7
Power Consumption W 1,095 1,480 2,450 2,660
ISEER
Indoor Unit Dimensions HxWxD mm 262x820x206 320x998x228 320x998x228 320x998x228
Indoor Unit Net Weight kg 7 14 14 14
Outdoor Unit Dimensions HxWxD mm 535x663x293 620x790x298 620x790x298 830x900x330
Outdoor Unit Net Weight kg 26 40 40 58
Indoor Noise Level (Quiet) dB(A) 22 26 33 33
Outdoor Noise Level dB(A) 52 50 56 53
Connection Pipe (Gas, Liquid)inch 3/8, 1/4 1/2, 1/4 5/8, 1/4 5/8, 3/8
mm 9.53/6.35 12.70/6.35 15.88/6.35 15.88/9.53
Pipe Length Min~Max (Precharged) m 3~15(10) 3~30(15) 3~30(15) 3~30(20)
Max Height Difference m 10 20 20 20
Operating Temperature oC 46oC 46oC 46oC 46oC
Refrigerant - R410A R410A R410A R410A
Compressor - Rotary Twin Rotary Twin Rotary Twin Rotary
TECH
NICA
L SP
ECIF
ICAT
IONS
*Speci�cations, design and features are subject to change without prior notice for further development. The above models conform to Energy labelling as per BEE regulation. Piping can be extended to above length for full ef�ciency with additional charge of gas and above 10mts/15 mts/20mts as per installation manual. The noise level is the value when measured in an anechoic room.
Hyper Tropical
~52°C
MILDEW RESISTANT FILTER
i-PAMCONTROL
DOUBLE SWINGAUTOMATIC - 3D 15m COANDA AIRFLOW
TECHNOLOGYQUIET OPERATION
SELFDIAGNOSIS
DOUBLE SWINGAUTOMATIC - 3D 15m COANDA AIRFLOW
TECHNOLOGYQUIET OPERATION
SELFDIAGNOSIS
TECH
NICA
L SP
ECIF
ICAT
IONS
PARAMETERS UNITS ASGA18FTTC ASGA22FTTC
BEE Star Rating - 3 3
Tonnage TR 1.5 1.8
Cooling CapacityW 5,300 6,500
BTU/hr 18,080 22,170
Moisture Removal l/hr 1.7 2.2
Indoor Airflow Volume-High m3/hr 985 1,120
Indoor Airflow Distance m 15 15
Power Supply V/Ph/Hz 220~240/1/50
Running Current A 6.8 8.3
Power Consumption W 1,510 1,850
ISEER W/W
Indoor Unit Dimensions HxWxD mm 320x998x238 320x998x238
Indoor Unit Net Weight kg 14 14
Outdoor Unit Dimensions HxWxD mm 650x830x320 830x900x330
Outdoor Unit Net Weight kg 51 63
Indoor Noise Level (Quiet) dB(A) 33 35
Outdoor Noise Level dB(A) 54 54
Connnection Pipe (Gas, Liquid)inch 5/8, 1/4 5/8, 1/4
mm 15.88/6.35 15.88/6.35
Pipe Length Min~Max (Precharged) m 3~20(7.5) 3~20(7.5)
Max Height Difference m 8 8
Max Operating Temperature oC 52oC 52oC
Refrigerant - R410A R410A
Compressor - Hyper Tropical Rotary Hyper Tropical Rotary
A9488 ETA General Cat 2018 Pg 16 17_A4 / 10 01 18 / RAJ
Catechin Filter
Deodorizing Filter
- - - - - - -
15m15m 15m15m
High Capacity Compressor
ASGA18FTTC
19,107
18,080
ASGA22FTTC
24,328
22,170
Compressor capacity higher than machine capacityensures powerful operation at high ambient temperature.
Model
CompressorCapacity
MachineCapacity
Units
BTU/hr
BTU/hr
Cooling AUG36FUAS/54FUAS
*Speci�cations, design and features are subject to change without prior notice for further development. Piping can be extended to above length for full ef�ciency with additional charge of gas and above 10mts/15 mts/20mts as per installation manual. The noise level is the value when measured in an anechoic room. Standard length of wired remote is 10m, which can be extended upto 500m. Wire spec is 22 AWG (0.33mm2).
ECO FRIENDLY
TECH
NICA
L SP
ECIF
ICAT
IONS
PARAMETERS UNITS AUG36FUAS AUG54FUAS
Tonnage TR 3.0 4.0
Cooling CapacityW 10,500 14,500
BTU/hr 35,800 49,500
Moisture Removal l/hr 4.0 6.0
Indoor Airflow Volume-High m3/hr 1,500 1,700
Power Supply V/Ph/Hz 400/3/50
Running Current A 6.2 9.5
Power Consumption W 3,740 5,160
EER W/W 2.81 2.81
Indoor Unit Dimensions HxWxD mm 296x830x830 296x830x830
Indoor Unit Net Weight kg 37 40
Grille Dimensions HxWxD mm 35x940x940 35x940x940
Outdoor Unit Dimensions HxWxD mm 1165x900x330 1290x900x330
Outdoor Unit Net Weight kg 80 114
Connection Pipe (Gas, Liquid)inch 5/8, 3/8 3/4, 3/8
mm 15.88/9.53 19.05/9.53
Pipe Length Min~Max (Precharged) m 3~50 (20) 3~50 (20)
Max Height Difference m 30 30
Max Operating Temperature oC 43oC 43oC
Refrigerant - R410A R410A
Compressor - Rotary Scroll
High Lift Drain Pump
296mm800mm
830mm
Ambient Operating Range
50
55
40
30
20
10
0
-10
Cooling
43°C
0°C
Cassette Air Conditioners
PROGRAM TIMERWEEKLY + SETBACK TIMER
QUIET OPERATIONConnectable distributing duct
SELFDIAGNOSIS
Fresh Air Intake &Distribution Duct
Distribution duct
Distributionduct
Fresh air
18 19
Eco-Friendly Cassette Air Conditioners
2-Stage Turbo FanHigh efficiency design by 2 stage structure
Previous turbo fan
Fast
Slow
Windvelocity In the case of a conventional
fan, the air outlet range was narrow as the airflow movedto the motor side which meant the velocity of air passing through the heat exchanger was uneven.
2-stage turbo fan
1-stage
+2-stage2 stage
Heat exchangeefficiency:
20%UP
An evenly spread air distribution acrossthe heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams.
Long-life filter
By placing the electrical component box inside the unit easy maintenance is assured.
(Service staff)
Easy MaintenanceDetachable, washable filter and intake grille.The control box is easily accessible for maintenance work.Wide opening for easy access.
4-way
3-way
2-way
Select 2-way, 3-way or 4-way airflow to suit your needs.
2-4 Way Airflow System
StepsAuto swing
43
2
1
1
2
3
4
Comfortable Airflow 4 Step SwingAuto airflow direction and auto swing ensures that supplied air does not blow over the ceiling.
Suitable for High Ceiling
Fresh air can be introduced through this opening.
Distribution duct
Distributionduct
Fresh air
2-way
1-way
Distributionduct
Distribution duct
Fresh air
2-way
Conditioned air can be distributed by meansof a distribution duct.
Duct Connection Hole Opening
Adoption of laminar wing
Spin direction Airflow direction
Quiet
Airflow runs through smoothly along the laminar wing
No airflow separation
Laminar wingQuiet
Extremely Quiet
Large airflow at reduced noise output is achieved by incorporating a large diameter variable pitch turbo fan.
Improvement of the Airflow Distribution
Reduced temperature irregularity by spreading airflow widelyBottom view
Front part Ceiling
Rear part
Round louver
The new louver design enables an airflow that has no air contact with the ceiling. Airflow is moved through the space between the chassis and the ceiling, allowing far and wide airflow distribution.
Optimization of wing form (laminar wing type) and wing number (7 blades each) designed by CFD-analysis(fluid) simulations
Ceiling Level
Floor Level
IndustryBest12ft
A9488 ETA General Cat 2018 Pg 18 19_A4_10_01_18_raj
20
THE MOST POWERFUL OUTDOOR LINE-UP
21
Designed to perform at high ambient temperatures General outdoor
units house tropical compressors along with a large condenser coil and
a large propeller fan which enable powerful cooling. These units can
withstand 1,000 hours of salt spray test, as per procedure ASTM B117.
These outdoor units are built heavier with corrosion-resistant materials
to make it long-lasting, sturdier and also quieter at the same time.
12JLCA 18JCC / 24JCC 30JCC / 22FTTC 30FUTC 36FUAS / 54FUAS18FUTC / 24FUTA / 18FTTC
Large Outdoor Fan
Hyper Tropical Compressor
TECH
NICA
L SP
ECIF
ICAT
IONS
OUTDOOR UNIT LINEUP PREMIUM SPLIT-COOLING INVERTER SPLIT-COOLING SPLIT-COOLING CASSETTE-COOLING
PARAMETERS UNITS ASGA18FUTC ASGA24FUTA ASGA30FUTC ASGA12JLCA ASGA18JCC ASGA24JCC ASGA30JCC ASGA18FTTC ASGA22FTTC AUG36FUAS AUG54FUAS
Tonnage TR 1.5 2.0 2.5 1.0 1.5 2.0 2.5 1.5 1.8 3.0 4.0
Cooling Capacity BTU/hr 18,660 24,260 27,910 11,940 17,740 24,220 27,300 18,080 22,170 35,800 49,500
Condenser Type - Copper Copper Copper Copper Copper Copper Copper Copper Copper Copper Copper
No. of Condenser Coil Rows - 1 2 3 2 2 2 2 2 2 2 2
Compressor Insulation Jacket - Yes Yes Yes vYes Yes Yes Yes Yes Yes Yes Yes
Outdoor Unit Fan Diameter mm 440 440 560 400 440 440 440 440 440 2 x 440 2 x 440
Condenser Protection Grill - Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes
Corrosion Resistant Body - Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Outdoor Unit Dimensions (HxWxD) mm 650x830x320 650x830x320 914x970x370 535x663x293 620x790x298 620x790x298 830x900x330 650x830x320 830x900x330 1165x900x330 1290x900x330
Outdoor Unit Net Weight kg 47 52 77 26 40 40 58 51 63 80 114
Outdoor Unit Air Circulation m3/h 3320 3070 4400 1850 2070 2640 3600 3200 3300 7000 6300
Outdoor Unit Noise Level dB(A) 53 55 54 52 50 56 53 54 54 54 54
Pipe Length Min~Max (Precharged) m 3~20(7.5) 3~20(7.5) 3~30(7.5) 3~15(10) 3~30(15) 3~30(15) 3~30(20) 3~20(7.5) 3~20(7.5) 3~50 (20) 3~50 (20)
Max Height Difference m 8 8 15 10 20 20 20 8 8 30 30
Max Operating Temp oC 52oC 52oC 52oC 46oC 46oC 46oC 46oC 52oC 52oC 43oC 43oC
Refrigerant Type - R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
Precharged Refrigerant g 1,200 1,600 2,450 750 1,200 1,300 2,000 1,400 1,800 2,000 3,300
Additional Refrigerant per Metre g/m 20 20 20 20 20 20 40 20 20 30 40
Compressor Type - Hyper Tropical Rotary Hyper Tropical Rotary Hyper Tropical Scroll Rotary Twin Rotary Twin Rotary Twin Rotary Hyper Tropical Rotary Hyper Tropical Rotary Rotary Scroll
Temperature rise prevention device (thermal protector) installed
High-output torque motor. Torque improved by increasing the thickness of the laminatedcore and improving the coil winding
High durability crankshaft with hardness improved by adding a coating
Gas leak protection and low voltage protection OLP (Over Load Protection) device installed
High durability rolling piston with hardness improved by changing the material
High durability vane.Surface hardness increased
A9488 ETA General Cat 2018 Pg 20 21_A4_10 01 18_raj
Optimized refrigerantflow design
High efficiency compressor motor
DC Twin Rotary Compressor
Highly accurate parts
R410ARefrigerant
R410ARefrigerant
R410ARefrigerant
R410ARefrigerant
R410ARefrigerant
WINDOW AIR CONDITIONERS
22 23
AXGT18FHTB / 24FHTB
Ef ficient, state-of-the-ar t Fujitsu-Japan fan motor with BSS sealing,CRS ball bearing and aluminum fin.
Fujitsu Fan Motor
Super Power / Super Wave
Long louver provides wide airflow
New, long louver
Wide airflow
Backside Louver
The only AC with a backside cover for additional protection to heat exchanger from sun and sand.
Advanced Technology
Large heat exchangerwith 6 row coil
Φ395mmDiameter 35mm largeragainst current model
Large and effectivepropeller fan
High Reliability
Adapting super protection against
dust and corrosion.Corrosion resistantheat exchanger
Aluminiumbracket motor
High Efficiency Condenser
(AXGT18FHTA)
*Speci�cations, design and features are subject to change without prior notice for further development. The above models conform to energy labelling as per BEE regulation. The noise level is the value when measured in an anechoic room.
Advanced
Feature Explanation
The outdoor unit's heat exchanger �ns are processedwith special coating to avoid salt and acid corrosion.
Corrosion resistant ODU
Wireless remote controllerFor ease of operation.
BLDC motor indoor unitSpecially designed BLDC motor for smooth & energy ef�cient operation.
Powder coated body ensures extra protection from corrosion.Powder coated outdoor unit
Inner groove copper tubeIGT copper tube heat exchanger ensures better performance.
Power air�ow dual �apsCan �atten out during cooling operation to deliver cool air to the corners of the room.
Wide angle louversThe smoothly curved wide angle louvers provide wide air�ow coverage for effective cooling independent of indoor unit placement in room.
High ef�ciency fan construction and large independently driven diffuser ensures quiet operation.
Quiet operation
Dry functionAutomatically reduces the level of humidity and maintains the preset temperature.
Energy saving modeThis mode raises the set temperature slightly in the cooling mode and lowers the set temperature in the heating mode to economically control the operation of the unit.
i-PAM control For improved voltage at the time of start.
ConnectableFresh Air Duct
For Cassette type air conditioners - 3.5 / 4.0TR
3 Year warranty on compressors
5 Year warranty on compressorsFor Inverter split and split type air conditioners upto 2.5TR
Cold air is discharged along the ceiling and is delivered far away for long reach and comfortable cooling and to avoid direct air blast on body.
Coanda Air�ow technology
Auto Moisture PreventDuring Cooling and Dry modes if the vertical air direction louvers are operated outside their proper operating range of (1) - (3) for more than 20 minutes, they will automatically return to the (3) level in order to prevant moisture condensation and water dropping from the air outlet. This can be disabled by following simple steps as mentioned in the operation manual.
Dual suction intake designWarm air is sucked in through dual intakes enabling larger volumeof air to be cooled for fast and effective cooling
Tropical design for high ambient operation upto 55oC.
Advanced Hyper tropical specAdvanced
S P E C
Tropical design for high ambient operation upto 52oC.
Hyper tropical specS P E C
Tropical design for high ambient operation upto 46oC.
Tropical specS P E C
6 Row CoilEnables faster and ef�cient cooling.
Wired remote controllerProgrammable wired remote, for ease of operation in busy commercial spaces.
Easy and extended location of indoor unit to outdoor unit with full ef�ciency.
Long pipe
Economy modeLimits the maximum operation current, and performs operations with the power consumption suppressed.
Powerful modeOperates at maximum air�ow and compressor speed to quickly make the room comfortable.POWERFULPOWERFUL
Up / down swing �apsThe up/down �aps automatically swing up and down.
Double swing automatic - 3DComplex swing action of �aps enables automatic swing in both horizontal and vertical directions, which enables 30 unique con�gurations
Auto restartIn the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored.
Automatic air�ow adjustmentThe micro-computer automatically adjusts the air�ow effectively to follow the changes in room temperature.
V-PAM control For improved compression speed.
Connectable distributing ductCan make extension of supply air.
Compressor insulation blanketSound insulation blanket and rubber mounting on compressor, reduces the noise.
Fresh air intakeFresh air can be taken in by a fan which can be connected using an external control unit.
Auto-ChangeoverThe operation mode (cooling, dry) is switched automatically to maintain the set temperature, and the temperature is kept constant at all times.
Sleep timerThe micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep.
10°C HEAT operationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
Auto-shut �apsWhen the AC is switched off, the louvers close automatically.
Removable and washable panelEasy removal and cleaning of the �at front panel of the IDU.
To protect the coil from damages due to sun and sand.Rear cabinet protection
Prevents mold formation. Mildew resistant �lter
Provides air�ow control in 5 steps from powerful to quiet operation.5 Speed Control5
Provides air�ow control in 6 steps from powerful to quiet operation.6 Speed Control6
Program timerThis digital timer allows selection of one of four options: ON, OFF, ON OFF or OFF ON.
Weekly + Setback timerWeekly + Setback timer can set temperature for two time spans and for each day of the week.
Advanced Hyper TropicalRotary Compressor
Advanced Hyper Tropical
~55°C
Self- DiagnosisEnables automatic detection of errorsin the unit for easy trouble shooting.
AUTO RESTARTREAR CABINET PROTECTION
6 ROW COIL(24FHTB)
SUPER WAVETECHNOLOGY
Super Wave TechnologyThe unique design of the vertical louvers in front will enablethe air sweep at wider angle for better distribution.
Mildew resistant �lter
Prevents mold formation
12
3
2
TECH
NICA
L SP
ECIF
ICAT
IONS
PARAMETERS UNITS AXGT18FHTB AXGT24FHTBBEE Star Rating - 3 3Tonnage TR 1.5 2.0
Cooling CapacityW 5,300 6,300
BTU/hr 18,085 21,100Moisture Removal l/hr 2.0 2.0Indoor Airflow Volume-High m3/hr 940 950Power Supply V/Ph/Hz 220~240/1/50Running Current A 8.1 9.6Power Consumption W 1,780 2,140ISEER W/WUnit Dimensions HxWxD mm 455x670x710 455x670x710Unit Net Weight kg 56 64Indoor Noise Level (Low) dB(A) 50 53Max Operating Temperature oC 55oC 55oCRefrigerant - R410A R410ACompressor - Advanced Hyper Tropical Rotary Advanced Hyper Tropical Rotary
A9488 ETA General Cat 2018 Pg 22 23_A4_10_01_18_raj
25
Feature SummaryL
ON
G L
IFE
Years of warranty on compressors
Anti -Corrosiontreatment for ODU and heat exchanger �ns
Powder coatedoudoor unit
CO
NV
EN
IEN
CE
Economy mode
Washable panel
Programtimer
Sleep timer
Wirelessremote controller
Wiredremote controller
Long pipe
Weekly + setback timer
PE
RF
OR
MA
NC
E
Powerful modePOWERFULPOWERFUL
BLDC motorindoor unit
Inner groovecopper tube
Features
INVERTERHOT AND COLDSPLIT INVERTER SPLIT CASSETTE
CO
MF
OR
T
Auto-changeover
Dry Function
Quietoperation
Compressorinsulation blanket
Up / downswing �aps
Automatic air�owadjustment
10°C Heatoperation
Connectable distributing duct
Double swingautomatic - 3D
Energy saving mode
V-PAM control models
i-PAM control models
Connectable fresh air duct
Auto Shut Flaps
Coanda Air�ow
Auto-MoisturePrevention
Mildew Resistant Filter
Fan Speed Control
Auto restart
ASGA30FUTC
ASGA18FUTCASGA24FUTA
5
20m/22m/25m
6
52◦c
ASGA18FTTCASGA24FTTC
5
3
52◦c
Single
ASGG12JLCA
5
4
(12)
10m
46◦c
ASGG18LFCDASGG24LFCDASGG30LFCE
5
4
15m
46◦c
ASGA18JCCASGA24JCC
5
4
(24)
(18)
15m
46◦c
ASGA30JCC
5
4
15m
46◦c
AUG36FUASAUG54FUAS
3
4
opt.
43◦cTropicalSpecS P E C
Dual suction intake design
Self- Diagnosis
24
Power air�owdual �aps
Wide anglelouvers
Feature Summary
WIN
DO
W
Features AXGT24FHTB AXGT18FHTB
Automatic air�ow adjustment
Powerful modePOWERFULPOWERFUL
Wireless remote controller
Compressor insulation blanket
Auto restart
Quiet operation
Rear cabinet protection
Mildew Resistant Filter
Advanced Hyper tropical rotary compressorSCROLL COMPRESSOR
Advanced
Auto-changeover
5 Year warranty on compressors
Number of Rows of Condenser Coil 5 6
55°c 55°cTropical SpecS P E C
Split Air Conditioner - Installation Check Points
Super Wave Technology
Use Torque wrench fortightening flare nuts.
Unit detail
Unit Capacity 1.5-Ton 1.8-Ton 1.5-Ton 2.0-Ton 2.5-Ton
Indoor model ASGA18FTTC ASGA22FTTC ASGA18FUTC ASGA24FUTA ASGA30FUTC
Outdoor model AOGA18FTTAH AOGA22FTTAH AOGA18FUTC AOGA24FUTA AOGA30FUTC
Check for Main power supply
Main wiring size 4 Sq. mm
Main Power Supply at OUTDOOR UNIT
Main power Source P & N 230 Volts / 1 Phase
Proper earthing Mandatory
Main power N & E ± 3 Volts
ODU to IDU Wiring
Maximum Current-Amps 12.5 Amps 15.9 Amps 10.0 Amps 14.0 Amps 17.0 Amps
Connection cord (mm2) 1.5 Sq. mm 2.5 Sq. mm 1.5 Sq. mm 2.5 Sq. mm 2.5 Sq. mm
No of core ODU to IDU 4 Core wire
Piping size & Thickness
Type of Gas R410A
Copper Pipe Thickness 0.8 mm & 1 mm 0.8 mm 0.8 mm/1 mm 0.8 mm/1 mm
Pipe size-Liquid (Inch)/mm 1/4” (6.35 mm) 1/4” (6.35mm) 1/4” (6.35mm) 3/8” (9.52 mm)
Pipe size-Suction (Inch)/mm 5/8” (15.88 mm) 5/8” (15.88 mm) 5/8” (15.88 mm) 5/8” (15.88 mm)
NEVER USE THE OLD INSTALLATION PIPE FOR NEW SYSTEM.
Pipe limitation & Additional
Refrigerant charge
Minimum Pipe Length
Max Pipe Length (A+B) 20m 30m
Maximum Height (B) 8m 15m
Pre-Charged Refrigerant 1400 gms 1800 gms 1200 gms 1600 gms 2450 gms
Standard Refrigerant Pre-Charged for 7.5 m
Additional Charge 20 gms/m
For long pipe length, use single pipe or connector and � aring connection, do not braze the copper tube (Braz-ing oxidation can clog unit expansion valve).
WARNING: This symbol shows that this equipment uses a � ammable refrigerant. If the refrigerant is leaked, together with an external ignition source, there is a possibility of ignition.
A9488 ETA General Cat 2018 Pg 24 25 / 10 01 18 / raj
2726
Coolworld IndustryAwards"Most Efficient AirConditioner"
China State ConstructionEngineering Luban Prize
productdesign award
2012
Gold Award (Category: HVAC & PLUMBING) in Reader’s Choice Awards
“Dealer DesignAwards”of “the NEWS”
ISO 9001Certified number : 01 100 89394
ISO 14001Certified number : 01 104 9245101
Fujitsu General (Shanghai) Co., Ltd.
ISO 9001Certified number : 01 100 79269
ISO 14001Certified number : 272043
Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.
ISO 9001Certified number : 00608Q11061R2M
ISO 14001Certified number : 00609E20454R2M
ISO
Certifications
RoHS Compliant
ASTM Our outdoor units shall withstand 1,000 hours of salt spray tested as per procedureASTM B117.
ISO14001 is the standard defined by the International Organization for Standardization
(ISO) related to environmental management systems. Fujitsu General America, Inc. has
been acknowledged by an internationally accredited compliance organization as having an
appropriate program of environmental protection procedures and activities to meet the
requirements of ISO14001. The air conditioners manufactured by Fujitsu have received
ISO9001 series certification for quality assurance. Fujitsu participates in the RoHS Directive, which is the Restriction
of Hazardous Substances in electrical and electronic equipment. It
is an EU directive intended to protect the environment by forcing
manufacturers to eliminate or severely curtail the use of cadmium,
hexavalent chromium, and lead in all products from automobiles to
consumer electronics. • ISO9001• ISO14001
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan
Inverter Split Air Conditioner - Installation Check Points
Must chargeby weight
Unit Capacity 1.0-Ton 1.5-Ton 2.0-Ton 2.5-Ton 1.5-Ton 2.0-Ton 2.5-Ton
Model No. ASGG12JLCA ASGA18JCC ASGA24JCC ASGA30JCC ASGG18LFCD ASGG24LFCD ASGG30LFCE
Check for Main power supply
Main wiring size 2.5 Sq. mm 4 Sq. mm
Main Power Supply at OUT DOOR UNIT
Main power Source P & N 230 Volts / 1 Phase
Proper earthing Mandatory
Main power N & E ± 3 Volts
ODU to IDU Wiring
Maximum Current-Amps (Cooling/Hea� ng) 7.0 Amps 9.0 Amps 11.5 Amps 16.5 Amps 9/12.5Amps 13.5/18.5Amps 13.5/18.5Amps
Connec� on cord (mm2) 1.5 Sq. mm 2.5 Sq. mm 1.5 Sq. mm 2.5 Sq. mm
No of core ODU to IDU 4 Core wire
Piping size & Thickness
Type of Gas R410a
Copper Pipe Thickness 0.8 mm 0.8 mm & 1 mm 0.8 mm 1 mm
Pipe size-Liquid (Inch)/mm 1/4” (6.35 mm) 3/8” (9.52 mm) 1/4” (6.35 mm) 3/8” (9.52 mm)
Pipe size-Suc� on (Inch)/mm 3/8”(9.52 mm) 1/2” (12.7 mm) 5/8” (15.88 mm) 1/2” (12.7 mm) 5/8” (15.88 mm)
NEVER USE THE OLD INSTALLATION PIPE FOR NEW SYSTEM.
Pipe limita� on & Addi� onal Ref charge
Minimum Pipe Length 3 Meter
MAX Pipe Length (A+B) 15 Meter 30 Meter
Maximum Height (B) 10 Meter 20 Meter
Pre-Charged Refrigerant (R410a) 750 grams 1200 grams 1300 grams 2000 grams 1200 grams 1800 grams 2000 grams
Standard Refrigerant Pre-Charged 10 Meter 15 Meter 20 Meter 15 Meter 20 Meter
Addi� onal Charge 20 Grams/Meter 40 Grams/Meter 20 Grams/Meter 40 Grams/Meter
For long pipe length, use single pipe or connecter and fl aringconnec� on, don’t braze the copper tube
(Brazing oxida� on can clog unit expansion valve.).
Use Torque wrench for � ghtening fl are-nuts.
In R410a gas purging is not allowed and must perform vacuum
Vacuumising is must for the Indoor & connec� ng Pipes, prior to allow the R410a Refrigerant into the Indoor unit. Perform Vacuumising upto -30Hg / 500 Microns. in the compound gauge.
R410a refrigerant must charge in liquid state
R410a charging should be done with the help of Charging scale, and the Charging should be in Liquid form only.
DO’s and DONT’s
1 Working pressure is 1.6 Times higher than R-22. Hence follow the safety norms while working with R410a Gas.
2 Always read the Installa� on sheet before star� ng the installa� on work (that come with the unit).
3 Use exclusive Refrigera� on tools for R410a Gas charging. No mix up of R22 Refrigerant tools.
4 Avoid direct sun radia� on on ODU and locate it in a shaded area always for be� er performance.
5 Never use the Old Copper pipes for the new system. Always use single length copper pipes between ODU
6 Use only the prescribed Flare nuts suitable for R410a.
7 Don’t use Teffl on Tape in fl are threads.
*Informa� on above are subject to change without prior no� ce
A9488 ETA General Cat 2018 Pg 26 27- A4_ 10 01 18 / raj