the most powerful air conditioner · 2018-01-17 · 10m 18m 20m 25m* powerful mode is more...

14
A9488 / India Catalogue January 2018 THE MOST POWERFUL AIR CONDITIONER 2017 ETA General Private Limited CORPORATE OFFICE: ETA Star House, No.71 / 63, 3rd Floor, Sterling Road, Nungambakkam, Chennai 600 034 | Ph: 044 43402345 | Fax: 044 43402343 Web: www.generalindia.com | e-mail: [email protected] REGISTERED OFFICE: R.S. Nos. 79 to 81, Kalitheerthalkuppam, Mannadipet, Puducherry 605 107, Ph. 044 43402345. CIN:U29308PY1999PTC001499. REGIONAL OFFICE: Delhi: 011 43127777 | Mumbai: 022 42455300 / 02 | Kolkata: 033 40060794. SERVICE: SOUTH: Bengaluru: 080 4092 6531 / 4092 6538, 97413 37111 | Bhubaneswar: 94372 53566 | Cochin: 0484 4011623, 90482 20228 Chennai/Puducherry: 90038 90377 | Coimbatore & Madurai: 98422 60111 | Hyderabad: 040 66103530 / 3531, 99633 44277 | Vijayawada: 0866 6460278 / 3074029, 99493 68627 | NORTH: Chandigarh: 0172 5087288, 98151 92456 | Delhi: 011 43127777, 99716 66755 | Ghaziabad: 0120 4291121, 88008 98435 Jaipur: 0141 4012684, 99280 55955 | Jamshedpur: 88722 19700 / 94315 67563 | Lucknow (U.P.): 0522 4006879, 77060 04008 | Ludhiana: 96464 85500 Mumbai: 022 42455300 / 5302, 89760 38396 | WEST: Ahmedabad/Surat/Gandhinagar: 40058991, 80000 79746 | Nagpur: 98817 46855 | Pune/Goa: 98231 90967 | Indore: 99260 01437 | MP: Bhopal: 99934 43691 | EAST: Patna: 93049 15264 | Raipur: 75818 10189 | Kolkata: 033 40060794, 83350 41629. BRANCH OFFICE: SOUTH: Bengaluru: 080 40926531 / 6538 | Kochi: 0484 4011623, 98478 16888 | North Kerala: 99950 08876 South Kerala: 93873 15113 Central Kerala: 86060 07879, 83010 84302 | Coimbatore: 0422 2220221, 97909 18207 | Madurai: 99655 84673 | Trichy: 98424 42308 Puducherry: 96558 81357 | Hyderabad: 040 66103530 / 3531, 40340011 | Vijayawada: 0866 6460278, 3074029 | NORTH: Greater Punjab (Himachal Pradesh, J&K, Haryana, Chandigarh & Punjab): 0172 5087288 / 7289 / 7290 | J&K: 98889 96580 | Chandigarh: 76969 10681 | Haryana (Karnal): 89505 69826 Lucknow: 0522 4006879 | Ghaziabad: 0120 4291121 | Jaipur: 0141 4012684 | Ludhiana: 82838 86960 | Jalandhar: 95305 11442 WEST: Ahmedabad: 079 27467991 / 2891, 40058991 | Goa: 98221 26401 | Indore: 99777 00830 | Nagpur: 98238 67510 Pune: 93257 16812, 93257 16807, 98903 90427 | Raipur: 81090 19220 | Bhopal: 99771 21274 | Surat: 0261 3924770, 98258 76503 | EAST: Patna: 88774 77555 | Ranchi: 97090 79555 Orissa: 0674 2572038, 78730 78714. We have not authorised any E-commerce site to sell our products. To buy General air conditioners online, please visit our e-Shop at www.generalindia.com Scan this QR code on your device to visit our website ALL INDIA CUSTOMER CARE 1860 2081 007 [email protected] AUTHORISED DEALERS ONLY 1860 258 3133 [email protected] A9488 ETA General Cat 2018 Pg 28 01 /A4 / 10 01 18 / raj

Upload: others

Post on 22-Feb-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:

A948

8 / I

ndia

Cat

alog

ue J

anua

ry 2

018

THE MOST POWERFUL AIR CONDITIONER

2017

ETA General Private Limited

CORPORATE OFFICE:

ETA Star House, No.71 / 63, 3rd Floor, Sterling Road, Nungambakkam, Chennai 600 034 | Ph: 044 43402345 | Fax: 044 43402343

Web: www.generalindia.com | e-mail: [email protected]

REGISTERED OFFICE: R.S. Nos. 79 to 81, Kalitheerthalkuppam, Mannadipet, Puducherry 605 107, Ph. 044 43402345. CIN:U29308PY1999PTC001499.

REGIONAL OFFICE: Delhi: 011 43127777 | Mumbai: 022 42455300 / 02 | Kolkata: 033 40060794.

SERVICE: SOUTH: Bengaluru: 080 4092 6531 / 4092 6538, 97413 37111 | Bhubaneswar: 94372 53566 | Cochin: 0484 4011623, 90482 20228

Chennai/Puducherry: 90038 90377 | Coimbatore & Madurai: 98422 60111 | Hyderabad: 040 66103530 / 3531, 99633 44277 | Vijayawada: 0866 6460278 /

3074029, 99493 68627 | NORTH: Chandigarh: 0172 5087288, 98151 92456 | Delhi: 011 43127777, 99716 66755 | Ghaziabad: 0120 4291121, 88008 98435

Jaipur: 0141 4012684, 99280 55955 | Jamshedpur: 88722 19700 / 94315 67563 | Lucknow (U.P.): 0522 4006879, 77060 04008 | Ludhiana: 96464 85500

Mumbai: 022 42455300 / 5302, 89760 38396 | WEST: Ahmedabad/Surat/Gandhinagar: 40058991, 80000 79746 | Nagpur: 98817 46855 | Pune/Goa:

98231 90967 | Indore: 99260 01437 | MP: Bhopal: 99934 43691 | EAST: Patna: 93049 15264 | Raipur: 75818 10189 | Kolkata: 033 40060794, 83350 41629.

BRANCH OFFICE: SOUTH: Bengaluru: 080 40926531 / 6538 | Kochi: 0484 4011623, 98478 16888 | North Kerala: 99950 08876 South Kerala: 93873 15113

Central Kerala: 86060 07879, 83010 84302 | Coimbatore: 0422 2220221, 97909 18207 | Madurai: 99655 84673 | Trichy: 98424 42308

Puducherry: 96558 81357 | Hyderabad: 040 66103530 / 3531, 40340011 | Vijayawada: 0866 6460278, 3074029 | NORTH: Greater Punjab (Himachal Pradesh,

J&K, Haryana, Chandigarh & Punjab): 0172 5087288 / 7289 / 7290 | J&K: 98889 96580 | Chandigarh: 76969 10681 | Haryana (Karnal): 89505 69826

Lucknow: 0522 4006879 | Ghaziabad: 0120 4291121 | Jaipur: 0141 4012684 | Ludhiana: 82838 86960 | Jalandhar: 95305 11442

WEST: Ahmedabad: 079 27467991 / 2891, 40058991 | Goa: 98221 26401 | Indore: 99777 00830 | Nagpur: 98238 67510 Pune: 93257 16812, 93257 16807,

98903 90427 | Raipur: 81090 19220 | Bhopal: 99771 21274 | Surat: 0261 3924770, 98258 76503 | EAST: Patna: 88774 77555 | Ranchi: 97090 79555

Orissa: 0674 2572038, 78730 78714.

We have not authorised any E-commerce site to sell our products. To buy General air conditioners online, please visit our e-Shop at www.generalindia.com

Scan this QR code on your deviceto visit our website

ALL INDIA CUSTOMER CARE

1860 2081 007 [email protected]

AUTHORISED DEALERS ONLY

1860 258 3133 [email protected]

A9488 ETA General Cat 2018 Pg 28 01 /A4 / 10 01 18 / raj

Page 2: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:
Page 3: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:
Page 4: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:

25m*20m10m 18m

Powerful mode is more power-up!

2

3

4

1

Super High

High

Med

Low

Quiet

Powerful*

*One touch powerful cooling mode: Continuous operation for 30 minutes at maximum air volume

5 speed + Powerful cooling mode

6 Speed Fan Control

1 Large display

2 Easy to operate new square design

3 One touch Powerful cooling mode

4 Easy to use large cursor key

Powerful and beautiful! New large wall mounted Split AC!

TROPICAL INNOVATION Series

ASGA18FUTC / ASGA24FUTA / ASGA30FUTC

Luxurious & Elegant Design

Golden Ornament Dual Suction Intake Design Trimmed Edge Design

New Design

New Technology

Possible to cool every corner of a big room immediately.

1

1

2

3

Large airflow volumefrom dual suction1

Current model

NEW model (+60mm)

New long cross-flow fan2 High output DC fan motor3

• Dual Suction• Optimized Airflow Design

ASGA30FUTC 25m*ASGA24FUTA 20mASGG12JLCA 10m ASGA18FUTC 18m ASGA30FUTC ASGA30FUTC 25m25m25m25m*ASGA24FUTA 20m20m20m20mASGG12JLCAASGG12JLCA 10m10m10m10m ASGA18FUTC 18m18m18m18m

06 07

15mASGG18LFCDASGG24LFCDASGG30LFCE

ASGA18JCCASGA24JCCASGA30JCCASGA18FTTCASGA22FTTC

Page 5: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:
Page 6: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:

10 11

Performance

For Tropical Innovation Series

Handy typeremote controller

Signal Transmitter Timer ButtonRemote Control Unit Display(LCD)

Horizontal Swing Button

Horizontal

Set Button

Fan Control Button

Temp/Time Set Button

Start/Stop Button

Sleep Button

Master Control Button/

Mode Change Button

Vertical Set Button

Vertical Swing Button

Remote Control Unit Display(LCD)

Signal Transmitter

Fan Control Button

Vertical Set Button

Vertical Swing Button

All Clear Button

Set Temp. Button

Master Control Button

Coil Dry Button*

Test Run Button

For Window AC

For Split AC

Timer Button

Sleep Button

Start/Stop Button

Feature Packed Remote

*Specifications & features may vary model-wise and are subject to change without notice.

Powerful and Compact DesignThough the indoor unit is compact, it features a large, high pressure cross fan (90mm diameter) in a center mounted configuration and a Lambda Type Heat Exchanger to provide plenty of power. The extra long diffuser provides a wide outflow opening for air. This ensures a large air outflow volume over a wide area to cool or heat all areas of the room.

High Air QualityPerfect comfort is ensured by the removal of dust, odor and bacteria in the air. Intake of fresh air, and other clean air conditioning technologies always takes health into consideration. Mildew resistant filter prevents mold formation in the indoor unit.

width:20.6cm

26.2cm

82.0cmSimple and compact design fits any interior decor

High efficiency BLDC MotorDC fan motor produces high power, wide operation range, and high efficiency.

• 20% increase in motor efficiency

• 20% lesser vibration

• Lower noise

Least Derration EffectGeneral Air Conditioners are designed to perform at ambient conditions as high as 60oC. Housed in larger outdoor units, the machines carry high BTU hyper-tropical compressors with large copper heat exchangers to ensure better heat transfer.

Blue Fin Condenserfor long lifeAdoption of strong blue fin hydrophillic c o a t e d he a t excha nge r p r ov i de s protection against rust and salt damage.

Hydrophillic Film

Corrosion-resistant

Acrylic Resin

Aluminium

Anti-Corrosion Treated Fin

Enhanced protection

Large Outdoor FanLarge fan (Ф 450x130) with power ful motor at high CFM for better heat transfer.

Performance

Temperature rise prevention device (thermal protector) installed

High-output torque motor. Torque improved by increasing the thickness of the laminatedcore and improving the coil winding

High durability crankshaft with hardness improved by adding a coating

Gas leak protection and low voltage protection OLP (Over Load Protection) device installed

High durability rolling piston with hardness improved by changing the material

High durability vane.Surface hardness increased

1.Improvement of compressor drive materials for greater durability (hardness increased).2.Use of high efficiency, high torque motor.3.Complete protection functions against abnormal temperature rise and abnormal pressure rise.

Hyper Tropical Spec

Super eco-friendlyCompressor based onEco-friendly R410A refrigerant designed forhigher ambient temperature of 52°C.

Super powerful10% more capacity than old modelsunder overload condition (60°C).

Super low voltage operationOur Hyper Tropical Compressor can be operated even at a low voltage.

Super Hi-EER5-10% higher than our old model.

Super quietReduces the noise level byabout 3dB at 220V operation.

Designed & developed by Fujitsu General

High Density Multi-Path Heat ExchangerHeat exchange performance is substantially improved by the thin high-density heat exchanger and multi-path efficiency technology. High performance grooved piping with expanded heat exchanger area is used for better heat transfer.

Ø5 mm

20 mm

Refrigerant

Multi-path

Distributor

Low NoiseSqueaking sound is eliminatedby simplifying the constructionof resin parts and using softresin at parts where stressis concentrated.

Adopting soft type resin

Base and casing integrated molding

One-piece panel (Unification of parts)

Tem

pera

ture

Time

Powerful

Setting temp.

Normal mode

Cooling time in normal mode is about 20% shorter than in high mode.

Pushbutton

Powerful OperationTwenty minutes of continuous operation by maximising airflow and at maximum compressor speed allows the temperature to reach optimum levels. Rapid cooling and heating makes the room comfortable quickly.

Powerful HeatingH i g h h e a t i n g c a p a c i t y i s realized even at low outdoor temperature by mounting a large heat exchanger and large DC rotary compressor along w i t h a h i g h p e r f o r ma n c e inverter PCB.

New Hyper Tropical Rotary Compressor

Realizing high-density heat transfer tube arrangement by making the tube thin

Volume reduction of heat

exchanger: 30%

Making the tube thin:

7mm 5mm

Even temperature

Improved the heatexchanger effectiveness

mm

Hyper TropicalRotary Compressor

Hyper Tropical

~52°C

A9488 ETA General Cat 2018 Pg 10 11 - A4 / 09 01 18 / Ajay

Start / stop button

Mode Button

TEMP. (temperature) buttons

Fan buttonsPowerful cooling button

Swing buttonVertical set button

Horizontal set button

Timer buttonSleep button

Reset button

Clock adjust buttonTest run button

Remote controller display

Signal transmitter

formation in the indoor unit.

26.2cm

Page 7: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:

12 13

OFF-ON timer

From sleep to wake-up

12

6

ON 9hours

OFF2hours

9 3PM9:00 set

ON-OFF timer

From wake-up to

go to work

OFF10hours

ON 7hours

12

6

9 3

PM11:00 set

Tem

p.

Economy operation

Shift setting temp

Normal operationTime

Set temperature

Power consumption10%down

ALL DC Saves Energy Throughout the YearBy making all the motors DC, electricity loss is decreased and power consumption is substantially reduced. In addition, high-speed fan motor rotation is possible, heat exchange efficiency is increased and annual power consumption amount is saved by increasing the airflow.

More Convenient TimerYou can set a program timer ON-OFF or OFF-ON timer that’s suitable for your lifestyle (Setting time: 0.5, 1, 1.5, 2, --- 9.5, 10, 11, 12 hours)

Economy OperationEconomy operation is for energy saving. As the set temperature of the indoor unit is shifted by 1°C, the load on the outdoor unit is minimised thus saving power by 10%.

Faster Cooling and Comfort ControlInverter ACs take half the time to reach the set temperature and precise control of room temperature is also attained.

Part Load EfficiencyMore power saving can be achieved by using Inverters as they operate under part-load condition most of the time.

DC Rotary CompressorThe high efficiency DC inverter type "rotary compressor" is used for our product ranges. It has achieved higher energy efficiency compared to similar compressors by optimizing the structure inside the compressor.

Sine-wave DC Inverter ControlHigh efficiency operation is realized by using a sine wave DC inverter control.

DC Fan Motor

Inverter Control Base

DC Compressor

Wide high efficiency rangeDC rotary compressor

Starting point: Set temperature: 240C, Operation Time: 3 hours, Room Inside: 350C, Outdoor: 350C (For 12000BTU/Hr model)

Set temperature

Compressor Speed

Set temperature

Compressor Speed

TECHNOLOGYINVERTER

What is an INVERTER air conditioner ?INVERTER is an equipment that controls the electrical voltage, current and frequency of the compressor motor in an air conditioner.

An INVERTER air conditioner changes the speed of the compressor by varying the frequency of the power supply to give superior cooling, ranging from high to low.

When an INVERTER air conditioner is started, the compressor runs at high speed for quick cooling. But once the set temperature is reached, the INVERTER air conditioner enters an ‘energy saving mode’ by reducing the compressor speed. Thus, effectively reducing its power in order to save energy.

In over 90% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity. We focused on high seasonal efficiency with and all DC inverter control and high efficiency technology.

I-PAM Control Panel

I-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform. This promotes the effective use of the input power supply to attain high performance.

I-PAM Control (PAM+IPM)Inverter Control

Time

SettingTemp.

Temp.

ConventionalInverter Control

I-PAMInverter Control

Conventional Inverter

I-PAM Inverter

“I-PAM (Intelligent power module – Pulse Amplitude Modulation)”

Energy saving and quick heating only possible by I-PAM

Illustrations and graphs may differfrom actual state

Our conventional typeInverter Model

Attain your desired temperature in just1/3 of the time compared to our conventional inverter models.

I-PAM Control Model

Voltage and speed of the compressor motorTemperature of 10 cm above floor

“V-PAM (Vector – Pulse Amplitude Modulation)”

V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and ef ficiency of the compressor by vector control technology. With this technology, further miniaturization, higher efficiency and better performance is attained.

It becomes more powerful with the newly developed high efficiency compressor motor control.

High

Electricity Charge

LowSaving electricity cost

Conventional Model

New model

Electricity costremains low

PowerHigh

LowOutput increased to greater thanthat of conventional models

Higher output thanour conventionalmodels

conventional models

New model

V-PAM (Vector + I-PAM)Inverter Control

Pursuit of Seasonal EfficiencyHighHigh

COP

COP

(%)(%)Heating part loadHeating part load

2525 5050 7575 100100

Frequent operation range

Faster Cooling

InverterCircuit

CompressorSpeed

CompressorSpeed

Power

Power

MAX

WideRange

50Hz

50Hz

MIN

NarrowRange

Accumulated power consumption

Inverter Model

Conventional Model

NON-INVERTER

Set

Temp.

SetTemp.

Temp.

Tem

p.

Tem

p.

Time

Energysaving

Power Supply

Power Supply

Temp.

Tem

p.

Time

More compact thanconventional models V-PAM

A9488 ETA General Cat 2018 Pg 12 13 - A4 / 11-01-18 / raj

Page 8: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:

15

*Speci�cations, design and features are subject to change without prior notice for further development. The above models conform to energy labelling as per BEE regulation. Piping can be extended to above length for full ef�ciency with additional charge of gas and above 10mts/15 mts/20mts as per installation manual. The noise level is the value when measured in an anechoic room.

*Speci�cations, design and features are subject to change without prior notice for further development. The above models conform to Energy labelling as per BEE regulation. Piping can be extended to above length for full ef�ciency with additional charge of gas and above 10mts/15 mts/20mts as per installation manual. The noise level is the value when measured in an anechoic room.

14

Premium Wall Mounted Split Air Conditioners

TROPICAL INNOVATION SeriesHot & Cold Wall Mounted Split Air Conditioners

INVERTER

15

Hot & Cold ASGG18LFCD / ASGG24LFCD / ASGG30LFCE

15m Long-reach Air�ow Ambient Operating Range

50

40

30

20

10

0

-10

-15

Cooling46°C

-10°C-15°C

24°CHeating

TECH

NICA

L SP

ECIF

ICAT

IONS

PARAMETERS CATEGORY UNITS ASGG18LFCD ASGG24LFCD ASGG30LFCEBEE Star Rating 5 4 4Tonnage - TR 1.5 2.0 2.5

Capacity (Range)Cooling kW 5.2(0.9~6.0) 7.1(0.9~8.0) 8.0(2.9~9.0)

BTU/hr 17,700(3,100~20,500) 24,200(3,100~27,300) 27,300(9,900~30,700)

Heating kW 6.3(0.9~9.1) 8.0(0.9~10.6) 8.8(2.2~11.0)BTU/hr 21,500(3,100~31,000) 27,300(3,100~36,200) 30,000(7,500~37,600)

Moisture Removal - l/hr 2.6 2.7 3.2Indoor Airflow Volume-High Indoor m3/hr 900 1,120 1,100Indoor Airflow Distance - m 15 15 15Power Supply - V/Ph/Hz 220~240/1/50

Running Current Cooling A 6.8 9.7 10.9Heating A 7.6 9.7 10.7

Power Consumption Cooling W 1,520 2,200 2,490Heating W 1,710 2,210 2,440

ISEER Cooling W/WEER Heating W/W 3.68 3.61 3.61Indoor Unit Dimensions HxWxD

Indoor mm 320x998x238 320x998x238 320x998x238Indoor Unit Net Weight kg 14 14 14Outdoor Unit Dimensions HxWxD Outdoor mm 620x790x290 620x790x290 830x900x330

Outdoor Unit Net Weight kg 41 41 61Indoor Noise Level (Quiet) - dB(A) 26 32 33

Outdoor Noise Level Cooling dB(A) 54 54 54Heating dB(A) 54 54 54

Connection Pipe (Gas, Liquid) - inch 1/2, 1/4 5/8, 1/4 5/8, 3/8- mm 12.70, 6.35 15.88, 6.35 15.88, 9.53

Pipe Length Min~Max (Precharged)

- m 3~25(15) 3~30 3~50

Max Height Difference - m 20 20 30

Operating Temperature Cooling oC -10oC~46oC -10oC~46oC -10oC~46oCHeating oC -15oC~24oC -15oC~24oC -15oC~24oC

Refrigerant - - R410A R410A R410ACompressor - - Twin Rotary Twin Rotary Twin Rotary

Cooling ASGA18FUTC / ASGA24FUTA / ASGA30FUTC

Ambient Operating Range

50

55

60

40

30

20

10

0

Cooling52°C

21°C

Super High

High

Med

Low

Quiet

Powerful

6 Speed Fan Control25m Long-reach Air�ow25m Long-reach Air�ow

25m

15m Long-reach Air�ow

UNITS ASGG18LFCD

15m15m

Blue Fin Condenser Catechin Filter

Hyper TropicalCompressor

Hyper Tropical

~52°C

DOUBLE SWINGAUTOMATIC - 3D

COANDA AIRFLOWTECHNOLOGY25m

DUAL SUCTIONINTAKE DESIGN

QUIET OPERATIONSELFDIAGNOSIS

DOUBLE SWINGAUTOMATIC - 3D 15m COANDA AIRFLOW

TECHNOLOGYi-PAMCONTROL

QUIET OPERATIONSELFDIAGNOSIS

TECH

NICA

L SP

ECIF

ICAT

IONS

TECH

NICA

L SP

ECIF

ICAT

IONS

PARAMETERS UNITS ASGA18FUTC ASGA24FUTA ASGA30FUTC

BEE Star Rating - 3 2 3

Tonnage TR 1.5 2.0 2.5

Cooling CapacityW 5,470 7,110 8,180

BTU/hr 18,660 24,260 27,910

Moisture Removal l/hr 1.0 2.0 2.5

Indoor Airflow Volume-Powerful/Super High/High/Med/Low/Quiet

m3/hr 1400/1250/1130/1000/870/740 1500/1350/1200/1050/900/740 1630/1520/1380/1260/1130/1000

Indoor Airflow Distance m 18 20 25

Power Supply V/Ph/Hz 220~240/1/50

Running Current A 6.9 9.4 10.5

Power Consumption W 1,560 2,100 2,340

ISEER W/W

Indoor Unit Dimensions HxWxD mm 340x1150x280 340x1150x280 340x1150x280

Indoor Unit Net Weight kg 16 16 17

Outdoor Unit Dimensions HxWxD mm 650x830x320 650x830x320 914x970x370

Outdoor Unit Net Weight kg 47 52 77

Indoor Noise Level (Quiet) dB(A) 34 35 41

Outdoor Noise Level dB(A) 53 55 54

Connection Pipe (Gas, Liquid)inch 5/8, 1/4 5/8, 1/4 5/8, 3/8

mm 15.88, 6.35 15.88, 6.35 15.88, 9.53

Pipe Length Min~Max (Precharged) m 3~20(7.5) 3~20(7.5) 3~30(7.5)

Max Height Difference m 8 8 15

Max Operating Temperature oC 52oC 52oC 52oC

Refrigerant - R410A R410A R410A

Compressor - Hyper Tropical Rotary Hyper Tropical Rotary Hyper Tropical Scroll

Deodorizing Filter

- - - - - - -

A9488 ETA General Cat 2018 Pg 14 15_A4 | 09 01 18 / Ajay

Page 9: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:

16 17

Cooling ASGA18FTTC / 22FTTC

Cooling ASGG12JLCA

Cooling ASGA18JCC / 24JCC / 30JCC

Ambient Operating Range

50

55

60

40

30

20

10

0

Cooling52°C

21°C

High

Med

Low

Auto

4 Speed Fan Control15m Long-reach Air�ow 4 Speed Fan Control15m Long-reach Air�ow

Hyper TropicalRotary Compressor

*Speci�cations, design and features are subject to change without prior notice for further development. The above models conform to energy labelling as per BEE regulation. Piping can be extended to above length for full ef�ciency with additional charge of gas and above 10mts/15 mts/20mts as per installation manual. The noise level is the value when measured in an anechoic room.

Cooling

46°C

18°C

50

40

30

10

20

18

Ambient Operating Range15m Long-reach Air�ow15m Long-reach Air�ow

INVERTERWall Mounted Split Air Conditioners

HYPER TROPICAL Wall Mounted Split Air Conditioners

PARAMETERS UNITS ASGG12JLCA ASGA18JCC ASGA24JCC ASGA30JCC

BEE Star Rating 4 5 4 4

Tonnage TR 1.0 1.5 2.0 2.5

Capacity (Range)kW 3.5(0.9~3.75) 5.2(0.9~6.0) 7.1(0.9~8.0) 8.0(2.9~9.0)

BTU/hr 11,940(3,100~13,600) 17,740(3,100~20,500) 24,220(3,100~27,300) 27,300(9,900~30,700)

Moisture Removal l/hr 1.8 2.8 3.0 3.0

Indoor Air� ow Volume-High m3/hr 720 900 1,100 1,100

Indoor Air� ow Distance m 10 15 15 15

Power Supply V/Ph/Hz 220~240/1/50

Running Current A 5.1 6.6 10.8 11.7

Power Consumption W 1,095 1,480 2,450 2,660

ISEER

Indoor Unit Dimensions HxWxD mm 262x820x206 320x998x228 320x998x228 320x998x228

Indoor Unit Net Weight kg 7 14 14 14

Outdoor Unit Dimensions HxWxD mm 535x663x293 620x790x298 620x790x298 830x900x330

Outdoor Unit Net Weight kg 26 40 40 58

Indoor Noise Level (Quiet) dB(A) 22 26 33 33

Outdoor Noise Level dB(A) 52 50 56 53

Connection Pipe (Gas, Liquid)inch 3/8, 1/4 1/2, 1/4 5/8, 1/4 5/8, 3/8

mm 9.53/6.35 12.70/6.35 15.88/6.35 15.88/9.53

Pipe Length Min~Max (Precharged) m 3~15(10) 3~30(15) 3~30(15) 3~30(20)

Max Height Difference m 10 20 20 20

Operating Temperature oC 46oC 46oC 46oC 46oC

Refrigerant - R410A R410A R410A R410A

Compressor - Rotary Twin Rotary Twin Rotary Twin Rotary

TECH

NICA

L SP

ECIF

ICAT

IONS

*Speci�cations, design and features are subject to change without prior notice for further development. The above models conform to Energy labelling as per BEE regulation. Piping can be extended to above length for full ef�ciency with additional charge of gas and above 10mts/15 mts/20mts as per installation manual. The noise level is the value when measured in an anechoic room.

Hyper Tropical

~52°C

MILDEW RESISTANT FILTER

i-PAMCONTROL

DOUBLE SWINGAUTOMATIC - 3D 15m COANDA AIRFLOW

TECHNOLOGYQUIET OPERATION

SELFDIAGNOSIS

DOUBLE SWINGAUTOMATIC - 3D 15m COANDA AIRFLOW

TECHNOLOGYQUIET OPERATION

SELFDIAGNOSIS

TECH

NICA

L SP

ECIF

ICAT

IONS

PARAMETERS UNITS ASGA18FTTC ASGA22FTTC

BEE Star Rating - 3 3

Tonnage TR 1.5 1.8

Cooling CapacityW 5,300 6,500

BTU/hr 18,080 22,170

Moisture Removal l/hr 1.7 2.2

Indoor Airflow Volume-High m3/hr 985 1,120

Indoor Airflow Distance m 15 15

Power Supply V/Ph/Hz 220~240/1/50

Running Current A 6.8 8.3

Power Consumption W 1,510 1,850

ISEER W/W

Indoor Unit Dimensions HxWxD mm 320x998x238 320x998x238

Indoor Unit Net Weight kg 14 14

Outdoor Unit Dimensions HxWxD mm 650x830x320 830x900x330

Outdoor Unit Net Weight kg 51 63

Indoor Noise Level (Quiet) dB(A) 33 35

Outdoor Noise Level dB(A) 54 54

Connnection Pipe (Gas, Liquid)inch 5/8, 1/4 5/8, 1/4

mm 15.88/6.35 15.88/6.35

Pipe Length Min~Max (Precharged) m 3~20(7.5) 3~20(7.5)

Max Height Difference m 8 8

Max Operating Temperature oC 52oC 52oC

Refrigerant - R410A R410A

Compressor - Hyper Tropical Rotary Hyper Tropical Rotary

A9488 ETA General Cat 2018 Pg 16 17_A4 / 10 01 18 / RAJ

Catechin Filter

Deodorizing Filter

- - - - - - -

15m15m 15m15m

High Capacity Compressor

ASGA18FTTC

19,107

18,080

ASGA22FTTC

24,328

22,170

Compressor capacity higher than machine capacityensures powerful operation at high ambient temperature.

Model

CompressorCapacity

MachineCapacity

Units

BTU/hr

BTU/hr

Page 10: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:

Cooling AUG36FUAS/54FUAS

*Speci�cations, design and features are subject to change without prior notice for further development. Piping can be extended to above length for full ef�ciency with additional charge of gas and above 10mts/15 mts/20mts as per installation manual. The noise level is the value when measured in an anechoic room. Standard length of wired remote is 10m, which can be extended upto 500m. Wire spec is 22 AWG (0.33mm2).

ECO FRIENDLY

TECH

NICA

L SP

ECIF

ICAT

IONS

PARAMETERS UNITS AUG36FUAS AUG54FUAS

Tonnage TR 3.0 4.0

Cooling CapacityW 10,500 14,500

BTU/hr 35,800 49,500

Moisture Removal l/hr 4.0 6.0

Indoor Airflow Volume-High m3/hr 1,500 1,700

Power Supply V/Ph/Hz 400/3/50

Running Current A 6.2 9.5

Power Consumption W 3,740 5,160

EER W/W 2.81 2.81

Indoor Unit Dimensions HxWxD mm 296x830x830 296x830x830

Indoor Unit Net Weight kg 37 40

Grille Dimensions HxWxD mm 35x940x940 35x940x940

Outdoor Unit Dimensions HxWxD mm 1165x900x330 1290x900x330

Outdoor Unit Net Weight kg 80 114

Connection Pipe (Gas, Liquid)inch 5/8, 3/8 3/4, 3/8

mm 15.88/9.53 19.05/9.53

Pipe Length Min~Max (Precharged) m 3~50 (20) 3~50 (20)

Max Height Difference m 30 30

Max Operating Temperature oC 43oC 43oC

Refrigerant - R410A R410A

Compressor - Rotary Scroll

High Lift Drain Pump

296mm800mm

830mm

Ambient Operating Range

50

55

40

30

20

10

0

-10

Cooling

43°C

0°C

Cassette Air Conditioners

PROGRAM TIMERWEEKLY + SETBACK TIMER

QUIET OPERATIONConnectable distributing duct

SELFDIAGNOSIS

Fresh Air Intake &Distribution Duct

Distribution duct

Distributionduct

Fresh air

18 19

Eco-Friendly Cassette Air Conditioners

2-Stage Turbo FanHigh efficiency design by 2 stage structure

Previous turbo fan

Fast

Slow

Windvelocity In the case of a conventional

fan, the air outlet range was narrow as the airflow movedto the motor side which meant the velocity of air passing through the heat exchanger was uneven.

2-stage turbo fan

1-stage

+2-stage2 stage

Heat exchangeefficiency:

20%UP

An evenly spread air distribution acrossthe heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams.

Long-life filter

By placing the electrical component box inside the unit easy maintenance is assured.

(Service staff)

Easy MaintenanceDetachable, washable filter and intake grille.The control box is easily accessible for maintenance work.Wide opening for easy access.

4-way

3-way

2-way

Select 2-way, 3-way or 4-way airflow to suit your needs.

2-4 Way Airflow System

StepsAuto swing

43

2

1

1

2

3

4

Comfortable Airflow 4 Step SwingAuto airflow direction and auto swing ensures that supplied air does not blow over the ceiling.

Suitable for High Ceiling

Fresh air can be introduced through this opening.

Distribution duct

Distributionduct

Fresh air

2-way

1-way

Distributionduct

Distribution duct

Fresh air

2-way

Conditioned air can be distributed by meansof a distribution duct.

Duct Connection Hole Opening

Adoption of laminar wing

Spin direction Airflow direction

Quiet

Airflow runs through smoothly along the laminar wing

No airflow separation

Laminar wingQuiet

Extremely Quiet

Large airflow at reduced noise output is achieved by incorporating a large diameter variable pitch turbo fan.

Improvement of the Airflow Distribution

Reduced temperature irregularity by spreading airflow widelyBottom view

Front part Ceiling

Rear part

Round louver

The new louver design enables an airflow that has no air contact with the ceiling. Airflow is moved through the space between the chassis and the ceiling, allowing far and wide airflow distribution.

Optimization of wing form (laminar wing type) and wing number (7 blades each) designed by CFD-analysis(fluid) simulations

Ceiling Level

Floor Level

IndustryBest12ft

A9488 ETA General Cat 2018 Pg 18 19_A4_10_01_18_raj

Page 11: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:

20

THE MOST POWERFUL OUTDOOR LINE-UP

21

Designed to perform at high ambient temperatures General outdoor

units house tropical compressors along with a large condenser coil and

a large propeller fan which enable powerful cooling. These units can

withstand 1,000 hours of salt spray test, as per procedure ASTM B117.

These outdoor units are built heavier with corrosion-resistant materials

to make it long-lasting, sturdier and also quieter at the same time.

12JLCA 18JCC / 24JCC 30JCC / 22FTTC 30FUTC 36FUAS / 54FUAS18FUTC / 24FUTA / 18FTTC

Large Outdoor Fan

Hyper Tropical Compressor

TECH

NICA

L SP

ECIF

ICAT

IONS

OUTDOOR UNIT LINEUP PREMIUM SPLIT-COOLING INVERTER SPLIT-COOLING SPLIT-COOLING CASSETTE-COOLING

PARAMETERS UNITS ASGA18FUTC ASGA24FUTA ASGA30FUTC ASGA12JLCA ASGA18JCC ASGA24JCC ASGA30JCC ASGA18FTTC ASGA22FTTC AUG36FUAS AUG54FUAS

Tonnage TR 1.5 2.0 2.5 1.0 1.5 2.0 2.5 1.5 1.8 3.0 4.0

Cooling Capacity BTU/hr 18,660 24,260 27,910 11,940 17,740 24,220 27,300 18,080 22,170 35,800 49,500

Condenser Type - Copper Copper Copper Copper Copper Copper Copper Copper Copper Copper Copper

No. of Condenser Coil Rows - 1 2 3 2 2 2 2 2 2 2 2

Compressor Insulation Jacket - Yes Yes Yes vYes Yes Yes Yes Yes Yes Yes Yes

Outdoor Unit Fan Diameter mm 440 440 560 400 440 440 440 440 440 2 x 440 2 x 440

Condenser Protection Grill - Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes

Corrosion Resistant Body - Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Outdoor Unit Dimensions (HxWxD) mm 650x830x320 650x830x320 914x970x370 535x663x293 620x790x298 620x790x298 830x900x330 650x830x320 830x900x330 1165x900x330 1290x900x330

Outdoor Unit Net Weight kg 47 52 77 26 40 40 58 51 63 80 114

Outdoor Unit Air Circulation m3/h 3320 3070 4400 1850 2070 2640 3600 3200 3300 7000 6300

Outdoor Unit Noise Level dB(A) 53 55 54 52 50 56 53 54 54 54 54

Pipe Length Min~Max (Precharged) m 3~20(7.5) 3~20(7.5) 3~30(7.5) 3~15(10) 3~30(15) 3~30(15) 3~30(20) 3~20(7.5) 3~20(7.5) 3~50 (20) 3~50 (20)

Max Height Difference m 8 8 15 10 20 20 20 8 8 30 30

Max Operating Temp oC 52oC 52oC 52oC 46oC 46oC 46oC 46oC 52oC 52oC 43oC 43oC

Refrigerant Type - R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A

Precharged Refrigerant g 1,200 1,600 2,450 750 1,200 1,300 2,000 1,400 1,800 2,000 3,300

Additional Refrigerant per Metre g/m 20 20 20 20 20 20 40 20 20 30 40

Compressor Type - Hyper Tropical Rotary Hyper Tropical Rotary Hyper Tropical Scroll Rotary Twin Rotary Twin Rotary Twin Rotary Hyper Tropical Rotary Hyper Tropical Rotary Rotary Scroll

Temperature rise prevention device (thermal protector) installed

High-output torque motor. Torque improved by increasing the thickness of the laminatedcore and improving the coil winding

High durability crankshaft with hardness improved by adding a coating

Gas leak protection and low voltage protection OLP (Over Load Protection) device installed

High durability rolling piston with hardness improved by changing the material

High durability vane.Surface hardness increased

A9488 ETA General Cat 2018 Pg 20 21_A4_10 01 18_raj

Optimized refrigerantflow design

High efficiency compressor motor

DC Twin Rotary Compressor

Highly accurate parts

R410ARefrigerant

R410ARefrigerant

R410ARefrigerant

R410ARefrigerant

R410ARefrigerant

Page 12: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:

WINDOW AIR CONDITIONERS

22 23

AXGT18FHTB / 24FHTB

Ef ficient, state-of-the-ar t Fujitsu-Japan fan motor with BSS sealing,CRS ball bearing and aluminum fin.

Fujitsu Fan Motor

Super Power / Super Wave

Long louver provides wide airflow

New, long louver

Wide airflow

Backside Louver

The only AC with a backside cover for additional protection to heat exchanger from sun and sand.

Advanced Technology

Large heat exchangerwith 6 row coil

Φ395mmDiameter 35mm largeragainst current model

Large and effectivepropeller fan

High Reliability

Adapting super protection against

dust and corrosion.Corrosion resistantheat exchanger

Aluminiumbracket motor

High Efficiency Condenser

(AXGT18FHTA)

*Speci�cations, design and features are subject to change without prior notice for further development. The above models conform to energy labelling as per BEE regulation. The noise level is the value when measured in an anechoic room.

Advanced

Feature Explanation

The outdoor unit's heat exchanger �ns are processedwith special coating to avoid salt and acid corrosion.

Corrosion resistant ODU

Wireless remote controllerFor ease of operation.

BLDC motor indoor unitSpecially designed BLDC motor for smooth & energy ef�cient operation.

Powder coated body ensures extra protection from corrosion.Powder coated outdoor unit

Inner groove copper tubeIGT copper tube heat exchanger ensures better performance.

Power air�ow dual �apsCan �atten out during cooling operation to deliver cool air to the corners of the room.

Wide angle louversThe smoothly curved wide angle louvers provide wide air�ow coverage for effective cooling independent of indoor unit placement in room.

High ef�ciency fan construction and large independently driven diffuser ensures quiet operation.

Quiet operation

Dry functionAutomatically reduces the level of humidity and maintains the preset temperature.

Energy saving modeThis mode raises the set temperature slightly in the cooling mode and lowers the set temperature in the heating mode to economically control the operation of the unit.

i-PAM control For improved voltage at the time of start.

ConnectableFresh Air Duct

For Cassette type air conditioners - 3.5 / 4.0TR

3 Year warranty on compressors

5 Year warranty on compressorsFor Inverter split and split type air conditioners upto 2.5TR

Cold air is discharged along the ceiling and is delivered far away for long reach and comfortable cooling and to avoid direct air blast on body.

Coanda Air�ow technology

Auto Moisture PreventDuring Cooling and Dry modes if the vertical air direction louvers are operated outside their proper operating range of (1) - (3) for more than 20 minutes, they will automatically return to the (3) level in order to prevant moisture condensation and water dropping from the air outlet. This can be disabled by following simple steps as mentioned in the operation manual.

Dual suction intake designWarm air is sucked in through dual intakes enabling larger volumeof air to be cooled for fast and effective cooling

Tropical design for high ambient operation upto 55oC.

Advanced Hyper tropical specAdvanced

S P E C

Tropical design for high ambient operation upto 52oC.

Hyper tropical specS P E C

Tropical design for high ambient operation upto 46oC.

Tropical specS P E C

6 Row CoilEnables faster and ef�cient cooling.

Wired remote controllerProgrammable wired remote, for ease of operation in busy commercial spaces.

Easy and extended location of indoor unit to outdoor unit with full ef�ciency.

Long pipe

Economy modeLimits the maximum operation current, and performs operations with the power consumption suppressed.

Powerful modeOperates at maximum air�ow and compressor speed to quickly make the room comfortable.POWERFULPOWERFUL

Up / down swing �apsThe up/down �aps automatically swing up and down.

Double swing automatic - 3DComplex swing action of �aps enables automatic swing in both horizontal and vertical directions, which enables 30 unique con�gurations

Auto restartIn the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored.

Automatic air�ow adjustmentThe micro-computer automatically adjusts the air�ow effectively to follow the changes in room temperature.

V-PAM control For improved compression speed.

Connectable distributing ductCan make extension of supply air.

Compressor insulation blanketSound insulation blanket and rubber mounting on compressor, reduces the noise.

Fresh air intakeFresh air can be taken in by a fan which can be connected using an external control unit.

Auto-ChangeoverThe operation mode (cooling, dry) is switched automatically to maintain the set temperature, and the temperature is kept constant at all times.

Sleep timerThe micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep.

10°C HEAT operationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

Auto-shut �apsWhen the AC is switched off, the louvers close automatically.

Removable and washable panelEasy removal and cleaning of the �at front panel of the IDU.

To protect the coil from damages due to sun and sand.Rear cabinet protection

Prevents mold formation. Mildew resistant �lter

Provides air�ow control in 5 steps from powerful to quiet operation.5 Speed Control5

Provides air�ow control in 6 steps from powerful to quiet operation.6 Speed Control6

Program timerThis digital timer allows selection of one of four options: ON, OFF, ON OFF or OFF ON.

Weekly + Setback timerWeekly + Setback timer can set temperature for two time spans and for each day of the week.

Advanced Hyper TropicalRotary Compressor

Advanced Hyper Tropical

~55°C

Self- DiagnosisEnables automatic detection of errorsin the unit for easy trouble shooting.

AUTO RESTARTREAR CABINET PROTECTION

6 ROW COIL(24FHTB)

SUPER WAVETECHNOLOGY

Super Wave TechnologyThe unique design of the vertical louvers in front will enablethe air sweep at wider angle for better distribution.

Mildew resistant �lter

Prevents mold formation

12

3

2

TECH

NICA

L SP

ECIF

ICAT

IONS

PARAMETERS UNITS AXGT18FHTB AXGT24FHTBBEE Star Rating - 3 3Tonnage TR 1.5 2.0

Cooling CapacityW 5,300 6,300

BTU/hr 18,085 21,100Moisture Removal l/hr 2.0 2.0Indoor Airflow Volume-High m3/hr 940 950Power Supply V/Ph/Hz 220~240/1/50Running Current A 8.1 9.6Power Consumption W 1,780 2,140ISEER W/WUnit Dimensions HxWxD mm 455x670x710 455x670x710Unit Net Weight kg 56 64Indoor Noise Level (Low) dB(A) 50 53Max Operating Temperature oC 55oC 55oCRefrigerant - R410A R410ACompressor - Advanced Hyper Tropical Rotary Advanced Hyper Tropical Rotary

A9488 ETA General Cat 2018 Pg 22 23_A4_10_01_18_raj

Page 13: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:

25

Feature SummaryL

ON

G L

IFE

Years of warranty on compressors

Anti -Corrosiontreatment for ODU and heat exchanger �ns

Powder coatedoudoor unit

CO

NV

EN

IEN

CE

Economy mode

Washable panel

Programtimer

Sleep timer

Wirelessremote controller

Wiredremote controller

Long pipe

Weekly + setback timer

PE

RF

OR

MA

NC

E

Powerful modePOWERFULPOWERFUL

BLDC motorindoor unit

Inner groovecopper tube

Features

INVERTERHOT AND COLDSPLIT INVERTER SPLIT CASSETTE

CO

MF

OR

T

Auto-changeover

Dry Function

Quietoperation

Compressorinsulation blanket

Up / downswing �aps

Automatic air�owadjustment

10°C Heatoperation

Connectable distributing duct

Double swingautomatic - 3D

Energy saving mode

V-PAM control models

i-PAM control models

Connectable fresh air duct

Auto Shut Flaps

Coanda Air�ow

Auto-MoisturePrevention

Mildew Resistant Filter

Fan Speed Control

Auto restart

ASGA30FUTC

ASGA18FUTCASGA24FUTA

5

20m/22m/25m

6

52◦c

ASGA18FTTCASGA24FTTC

5

3

52◦c

Single

ASGG12JLCA

5

4

(12)

10m

46◦c

ASGG18LFCDASGG24LFCDASGG30LFCE

5

4

15m

46◦c

ASGA18JCCASGA24JCC

5

4

(24)

(18)

15m

46◦c

ASGA30JCC

5

4

15m

46◦c

AUG36FUASAUG54FUAS

3

4

opt.

43◦cTropicalSpecS P E C

Dual suction intake design

Self- Diagnosis

24

Power air�owdual �aps

Wide anglelouvers

Feature Summary

WIN

DO

W

Features AXGT24FHTB AXGT18FHTB

Automatic air�ow adjustment

Powerful modePOWERFULPOWERFUL

Wireless remote controller

Compressor insulation blanket

Auto restart

Quiet operation

Rear cabinet protection

Mildew Resistant Filter

Advanced Hyper tropical rotary compressorSCROLL COMPRESSOR

Advanced

Auto-changeover

5 Year warranty on compressors

Number of Rows of Condenser Coil 5 6

55°c 55°cTropical SpecS P E C

Split Air Conditioner - Installation Check Points

Super Wave Technology

Use Torque wrench fortightening flare nuts.

Unit detail

Unit Capacity 1.5-Ton 1.8-Ton 1.5-Ton 2.0-Ton 2.5-Ton

Indoor model ASGA18FTTC ASGA22FTTC ASGA18FUTC ASGA24FUTA ASGA30FUTC

Outdoor model AOGA18FTTAH AOGA22FTTAH AOGA18FUTC AOGA24FUTA AOGA30FUTC

Check for Main power supply

Main wiring size 4 Sq. mm

Main Power Supply at OUTDOOR UNIT

Main power Source P & N 230 Volts / 1 Phase

Proper earthing Mandatory

Main power N & E ± 3 Volts

ODU to IDU Wiring

Maximum Current-Amps 12.5 Amps 15.9 Amps 10.0 Amps 14.0 Amps 17.0 Amps

Connection cord (mm2) 1.5 Sq. mm 2.5 Sq. mm 1.5 Sq. mm 2.5 Sq. mm 2.5 Sq. mm

No of core ODU to IDU 4 Core wire

Piping size & Thickness

Type of Gas R410A

Copper Pipe Thickness 0.8 mm & 1 mm 0.8 mm 0.8 mm/1 mm 0.8 mm/1 mm

Pipe size-Liquid (Inch)/mm 1/4” (6.35 mm) 1/4” (6.35mm) 1/4” (6.35mm) 3/8” (9.52 mm)

Pipe size-Suction (Inch)/mm 5/8” (15.88 mm) 5/8” (15.88 mm) 5/8” (15.88 mm) 5/8” (15.88 mm)

NEVER USE THE OLD INSTALLATION PIPE FOR NEW SYSTEM.

Pipe limitation & Additional

Refrigerant charge

Minimum Pipe Length

Max Pipe Length (A+B) 20m 30m

Maximum Height (B) 8m 15m

Pre-Charged Refrigerant 1400 gms 1800 gms 1200 gms 1600 gms 2450 gms

Standard Refrigerant Pre-Charged for 7.5 m

Additional Charge 20 gms/m

For long pipe length, use single pipe or connector and � aring connection, do not braze the copper tube (Braz-ing oxidation can clog unit expansion valve).

WARNING: This symbol shows that this equipment uses a � ammable refrigerant. If the refrigerant is leaked, together with an external ignition source, there is a possibility of ignition.

A9488 ETA General Cat 2018 Pg 24 25 / 10 01 18 / raj

Page 14: THE MOST POWERFUL AIR CONDITIONER · 2018-01-17 · 10m 18m 20m 25m* Powerful mode is more power-up! 2 3 4 1 Super High High Med Low Quiet Powerful* *One touch powerful cooling mode:

2726

Coolworld IndustryAwards"Most Efficient AirConditioner"

China State ConstructionEngineering Luban Prize

productdesign award

2012

Gold Award (Category: HVAC & PLUMBING) in Reader’s Choice Awards

“Dealer DesignAwards”of “the NEWS”

ISO 9001Certified number : 01 100 89394

ISO 14001Certified number : 01 104 9245101

Fujitsu General (Shanghai) Co., Ltd.

ISO 9001Certified number : 01 100 79269

ISO 14001Certified number : 272043

Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.

ISO 9001Certified number : 00608Q11061R2M

ISO 14001Certified number : 00609E20454R2M

ISO

Certifications

RoHS Compliant

ASTM Our outdoor units shall withstand 1,000 hours of salt spray tested as per procedureASTM B117.

ISO14001 is the standard defined by the International Organization for Standardization

(ISO) related to environmental management systems. Fujitsu General America, Inc. has

been acknowledged by an internationally accredited compliance organization as having an

appropriate program of environmental protection procedures and activities to meet the

requirements of ISO14001. The air conditioners manufactured by Fujitsu have received

ISO9001 series certification for quality assurance. Fujitsu participates in the RoHS Directive, which is the Restriction

of Hazardous Substances in electrical and electronic equipment. It

is an EU directive intended to protect the environment by forcing

manufacturers to eliminate or severely curtail the use of cadmium,

hexavalent chromium, and lead in all products from automobiles to

consumer electronics. • ISO9001• ISO14001

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan

Inverter Split Air Conditioner - Installation Check Points

Must chargeby weight

Unit Capacity 1.0-Ton 1.5-Ton 2.0-Ton 2.5-Ton 1.5-Ton 2.0-Ton 2.5-Ton

Model No. ASGG12JLCA ASGA18JCC ASGA24JCC ASGA30JCC ASGG18LFCD ASGG24LFCD ASGG30LFCE

Check for Main power supply

Main wiring size 2.5 Sq. mm 4 Sq. mm

Main Power Supply at OUT DOOR UNIT

Main power Source P & N 230 Volts / 1 Phase

Proper earthing Mandatory

Main power N & E ± 3 Volts

ODU to IDU Wiring

Maximum Current-Amps (Cooling/Hea� ng) 7.0 Amps 9.0 Amps 11.5 Amps 16.5 Amps 9/12.5Amps 13.5/18.5Amps 13.5/18.5Amps

Connec� on cord (mm2) 1.5 Sq. mm 2.5 Sq. mm 1.5 Sq. mm 2.5 Sq. mm

No of core ODU to IDU 4 Core wire

Piping size & Thickness

Type of Gas R410a

Copper Pipe Thickness 0.8 mm 0.8 mm & 1 mm 0.8 mm 1 mm

Pipe size-Liquid (Inch)/mm 1/4” (6.35 mm) 3/8” (9.52 mm) 1/4” (6.35 mm) 3/8” (9.52 mm)

Pipe size-Suc� on (Inch)/mm 3/8”(9.52 mm) 1/2” (12.7 mm) 5/8” (15.88 mm) 1/2” (12.7 mm) 5/8” (15.88 mm)

NEVER USE THE OLD INSTALLATION PIPE FOR NEW SYSTEM.

Pipe limita� on & Addi� onal Ref charge

Minimum Pipe Length 3 Meter

MAX Pipe Length (A+B) 15 Meter 30 Meter

Maximum Height (B) 10 Meter 20 Meter

Pre-Charged Refrigerant (R410a) 750 grams 1200 grams 1300 grams 2000 grams 1200 grams 1800 grams 2000 grams

Standard Refrigerant Pre-Charged 10 Meter 15 Meter 20 Meter 15 Meter 20 Meter

Addi� onal Charge 20 Grams/Meter 40 Grams/Meter 20 Grams/Meter 40 Grams/Meter

For long pipe length, use single pipe or connecter and fl aringconnec� on, don’t braze the copper tube

(Brazing oxida� on can clog unit expansion valve.).

Use Torque wrench for � ghtening fl are-nuts.

In R410a gas purging is not allowed and must perform vacuum

Vacuumising is must for the Indoor & connec� ng Pipes, prior to allow the R410a Refrigerant into the Indoor unit. Perform Vacuumising upto -30Hg / 500 Microns. in the compound gauge.

R410a refrigerant must charge in liquid state

R410a charging should be done with the help of Charging scale, and the Charging should be in Liquid form only.

DO’s and DONT’s

1 Working pressure is 1.6 Times higher than R-22. Hence follow the safety norms while working with R410a Gas.

2 Always read the Installa� on sheet before star� ng the installa� on work (that come with the unit).

3 Use exclusive Refrigera� on tools for R410a Gas charging. No mix up of R22 Refrigerant tools.

4 Avoid direct sun radia� on on ODU and locate it in a shaded area always for be� er performance.

5 Never use the Old Copper pipes for the new system. Always use single length copper pipes between ODU

6 Use only the prescribed Flare nuts suitable for R410a.

7 Don’t use Teffl on Tape in fl are threads.

*Informa� on above are subject to change without prior no� ce

A9488 ETA General Cat 2018 Pg 26 27- A4_ 10 01 18 / raj