the irish tabula project - Österreichische energieagentur · 2012. 8. 16. · 3....
TRANSCRIPT
![Page 1: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/1.jpg)
1
The Irish TABULA Project
How Typologies assist with the Irish National Retrofit Programme
Michael Hanratty, Energy Action International Expert Workshop, Wels 29th February 2012
"The sole responsibility for the content of this presentation lies with the authors. It does not represent the opinion of the Community. The European Commission is not responsible for any use that may be made of the information contained therein."
![Page 2: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/2.jpg)
2
TABULA Building Matrix of Irish Dwellings
• 1.6 million residen.al buildings in Ireland ( 1.4m family houses, 200,000 apartments) • 30 residen.al building types in Irish typology
![Page 3: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/3.jpg)
3
Standard Measures (Stage 1) Based on Sustainable Energy Authority of IreIand (SEAI)
Better Energy Homes Standard* Stage 1 Measures Upgrade Standards
Roof U-Value 0.13 W/m2K Flat roofs 0.22 W/m2K Wall U-Value 0.27 W/m2K Wooden Floor (replace) 0.25 W/m2K Windows U-Value 2 W/m2K Doors (PVC) 2 W/m2K Space heat generator efficiency 90% gas, oil Water heat generator efficiency 90% gas, oil
Heating controls Full zone control Cylinder Insulation 50mm, spray foam
![Page 4: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/4.jpg)
4
Advanced Measures: (Stage 2) Proposal
Stage 2 is an advancement on SEAI Better Energy Homes Scheme U Values are based on Building Regulations 2011
Stage 2 Measures Upgrade Standards Roof U-Value 0.13 W/m2K Flat roof 0.20 Wm2K Wall U-Value 0.21 W/m2K Windows U-Value 1.3 W/m2K Doors (PVC) 2 W/m2K
Space heat generator efficiency Heat pump: 380% min air, 400% ground
Water heat generator efficiency Heat pump: 380% min air, 400% ground
Plus Solar thermal (4m2 to 6m2) 40% contribution of total energy (10% electric immersion)
Heating controls Full zone control Cylinder Insulation 50mm, spray foam Mechanical Heat Recovery Ventilation 80% minimum efficiency
![Page 5: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/5.jpg)
5
![Page 6: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/6.jpg)
6
![Page 7: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/7.jpg)
7
National Energy Efficiency Action Plan 2009 - 2020
Ø 20% reduction in energy use by 2020
Ø 20% national target = 32,000 GWh
Ø I million building upgrades across residential, commercial & public sector to achieve 8,000 GWh savings
Ø Residential sector savings to be achieved via higher standards for new building, retrofitting older building stock, efficient boiler standards, green technologies and smart metering etc
![Page 8: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/8.jpg)
8
Government Grants for Retrofits of Privately Owned Houses in Ireland (2011)
Measure Grant Available (2011)
Roof Insulation Ceiling Level
€200 Rafter Level
Wall Insulation
Cavity Fill €250 Dry-lining Insulation Apartment (any) OR Mid-terrace House
€900
Semi-detached or End of Terrace €1,350 Detached House €1,800 External Insulation Apartment (any) OR Mid-terrace House
€1,800
Semi-detached or End of Terrace €2,700 Detached House €3,600
Heating System
High Efficiency Gas Boiler installation with Heating Controls Upgrade
€560 High Efficiency Oil Boiler installation with Heating Controls Upgrade Heating Controls Upgrade Only €400 Solar Heating €800
Building Energy Rating Cert €50 Windows Replace/upgrade existing windows No Grant available
![Page 9: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/9.jpg)
9
Government Grants for Retrofits of Social Housing
(owned by Local Authorities)
Energy Saving per Year (kWh/m2/year) Grant (lesser of)
Minimum % from Local Authority
>300 kWh 90% or €18,000 10%
200-‐300 kWh 90% or €15,500 10%
100-‐200 kWh 75% or €11,500 25%
50-‐100 kWh 50% or €6,000 50%
![Page 10: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/10.jpg)
10
Refurbishment Rates for Irish Housing Stock (2000-2011)
• Low income homes received 1 to 2 measures • Private homes received 2 to 3 measures • 35,000 houses also had renewable technology installa.ons • NB: EPCs (BERs) were issued for the majority of these buildings
Low Income Homes Private Homes Social Housing
2000-‐2006 11,000
2007 4,000
2008 5,000
2009 15,000 20,000 1,200
2010 20,000 40,000 1,800
2011 25,000 50,000 3,000
Totals 80,000 110,000 6,000
![Page 11: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/11.jpg)
11
Comparing TABULA Results to data in SEAI’s Database of 225,00 BERs
TABULA Type
Pre-‐1978 TABULA House types
TABULA Typical Primary Energy Value kWh/m2/a
NaNonal EPC Database Average Primary Energy Value kWh/m2/a Varia.on
Varia.on as % of TABULA typical Primary Energy Value
SEAI NAS Max kWh/m2/a
SEAI Min kWh/m2/a
1 SFH.01.Gen 484 366 118 24% 8901 75
2 TH.01.Gen 489 314 175 36% 8031 101
3 SFH.01.Stone 618 440 178 29% 11824 95
4 TH.01.Stone 607 410 197 32% 6724 93
5 SFH.01.225SB 634 443 191 30% 1736 119
6 TH.01.225SB 464 390 73 16% 5627 119
7 SFH.01.325SB 454 383 71 16% 2702 110
8 TH.01.325SB 632 381 250 40% 6484 98
9 SFH.01.MassConc 657 507 150 23% 15393 121
1. BER database includes many houses that have received grant-supported upgrades
2. TABULA house type are based on one specific fuel type
Source: SEAI, October 2011 G Rating
![Page 12: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/12.jpg)
12
EPCs Published for Type 1
Number Percentage A1 0 0% A2 0 0% A3 0 0% B1 5 0% B2 26 0% B3 73 1% C1 145 3% C2 233 4% C3 352 7% D1 437 8% D2 613 12% E1 470 9% E2 495 9% F 718 14% G 1751 33%
5318 100%
0%
5%
10%
15%
20%
25%
30%
35%
A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G
1. Detached House, stone walls, pre-1978
A1
A2
A3
B1
B2
B3
C1
C2
C3
D1
D2
E1
E2
35% are D2 or better
![Page 13: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/13.jpg)
13
EPCs Published for Type 2
Number Percentage A1 0 0% A2 0 0% A3 0 0% B1 1 0% B2 19 0% B3 71 1% C1 201 3% C2 380 6% C3 561 8% D1 920 13% D2 1025 15% E1 665 10% E2 759 11% F 944 14% G 1351 20%
6897 100%
0%
5%
10%
15%
20%
25%
A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G
2. End of terrace house, stone walls, pre-1978
A1
A2
A3
B1
B2
B3
C1
C2
C3
D1
D2
E1
E2
44% are D2 or better
![Page 14: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/14.jpg)
14
External Insulation in 2011 in Tralee, Co Kerry
Area-‐based project led by Electric Ireland 80 houses refurbished with external wall insula.on and roof insula.on 2011/2012 All will connect to new wood chip boiler district hea.ng system in 2012
Photos courtesy of Electric Ireland
![Page 15: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/15.jpg)
15
EPCs Published for Type 10
Number Percentage A1 0 0% A2 0 0% A3 6 0% B1 54 1% B2 124 2% B3 291 4% C1 443 6% C2 644 9% C3 828 12% D1 1168 17% D2 1160 17% E1 648 9% E2 530 8% F 529 8% G 414 6%
6839 100% 0%
2%
4%
6%
8%
10%
12%
14%
16%
18%
A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G
Semi detached, hollow block walls, pre-1978
A1
A2
A3
B1
B2
B3
C1
C2
C3
D1
D2
E1
69% are D2 or better
![Page 16: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/16.jpg)
16
EPCs Published for Type 11
0%
2%
4%
6%
8%
10%
12%
14%
16%
A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G
Terraced house, hollow block walls pre-1978
A1
A2
A3
B1
B2
B3
C1
C2
C3
D1
Number Percentage A1 0 0% A2 0 0% A3 0 0% B1 20 1% B2 40 2% B3 83 5% C1 129 7% C2 151 9% C3 192 11% D1 235 14% D2 249 14% E1 170 10% E2 160 9% F 147 8% G 163 9%
1739 100%
64% are D2 or better
![Page 17: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/17.jpg)
17
External Insulation in last 3 years on same street
Individual home-‐owners had EWI installed All availed of energy efficiency grant support 9 homes on the same street so far
![Page 18: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/18.jpg)
18
EPCs Published for Type 12
0%
2%
4%
6%
8%
10%
12%
14%
16%
18%
A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G
12. Detached House, cavity walls pre-1978
A1
A2
A3
B1
B2
B3
C1
C2
C3
D1
D2
E1
Number Percentage A1 0 0% A2 1 0% A3 37 0% B1 125 1% B2 377 2% B3 1445 8% C1 2257 12% C2 2856 15% C3 3157 16% D1 3044 16% D2 2560 13% E1 1130 6% E2 776 4% F 696 4% G 768 4%
19229 100%
The most recent update of the Irish EPC sobware (December 2011) includes data on the purpose of the EPC cer.ficate
![Page 19: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/19.jpg)
19
EPCs Published for Type 13 Number Percentage
A1 0 0% A2 0 0% A3 29 0% B1 194 1% B2 492 2% B3 1707 6% C1 3199 11% C2 4107 14% C3 4941 17% D1 5038 17% D2 4015 14% E1 2077 7% E2 1469 5% F 1297 4% G 1026 3%
29591 100%
0% 2% 4% 6% 8%
10% 12% 14% 16% 18%
A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G
13. End Terrace house, cavity walls, pre-1978
A1
A2
A3
B1
B2
B3
C1
C2
Summary: 1. EPC database is strongly influenced by refurbished buildings so
be careful in drawing conclusions from EPC database 2. The EPC scores of refurbished buildings correspond to TABULA
refurbishment steps 3. The TABULA brochures will contribute posi.vely to na.onal
retrofit programmes
![Page 20: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/20.jpg)
20
So do typology results & studies contribute to Retrofit Programmes?
Ø The response from Irish homeowners, building energy experts and the retrofit industry to the typology brochures has been enthusiastic
Ø There is significant demand to expand & refine the Irish typology as the National Retrofit progamme develops out to 2020
Ø Draft of new Code of Practice (COP) for Retrofitting of Dwellings will issue from the Department of Environment in March 2012. Three building types from the Irish TABULA project are included in the COP.
![Page 21: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology](https://reader035.vdocuments.mx/reader035/viewer/2022071302/60ad465f8592ba1540498f6b/html5/thumbnails/21.jpg)
21
Irish Project
"The sole responsibility for the content of this presentation lies with the authors. It does not represent the opinion of the Community. The European Commission is not responsible for any use that may be made of the information contained therein."
Thank you for your attention