1 The Irish TABULA Project How Typologies assist with the Irish National Retrofit Programme Michael Hanratty, Energy Action International Expert Workshop, Wels 29 th February 2012 "The sole responsibility for the content of this presentation lies with the authors. It does not represent the opinion of the Community. The European Commission is not responsible for any use that may be made of the information contained therein."

Upload: others

Post on 22-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

1

The Irish TABULA Project

How Typologies assist with the Irish National Retrofit Programme

Michael Hanratty, Energy Action International Expert Workshop, Wels 29th February 2012

"The sole responsibility for the content of this presentation lies with the authors. It does not represent the opinion of the Community. The European Commission is not responsible for any use that may be made of the information contained therein."

Page 2: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

2

TABULA Building Matrix of Irish Dwellings

•     1.6  million  residen.al  buildings  in  Ireland        (      1.4m  family  houses,  200,000  apartments)    •   30  residen.al  building  types  in  Irish  typology  

Page 3: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

3

Standard Measures (Stage 1) Based on Sustainable Energy Authority of IreIand (SEAI)

Better Energy Homes Standard* Stage 1 Measures Upgrade Standards

Roof U-Value 0.13 W/m2K Flat roofs 0.22 W/m2K Wall U-Value 0.27 W/m2K Wooden Floor (replace) 0.25 W/m2K Windows U-Value 2 W/m2K Doors (PVC) 2 W/m2K Space heat generator efficiency 90% gas, oil Water heat generator efficiency 90% gas, oil

Heating controls Full zone control Cylinder Insulation 50mm, spray foam

Page 4: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

4

Advanced Measures: (Stage 2) Proposal

Stage 2 is an advancement on SEAI Better Energy Homes Scheme U Values are based on Building Regulations 2011

Stage 2 Measures Upgrade Standards Roof U-Value 0.13 W/m2K Flat roof 0.20 Wm2K Wall U-Value 0.21 W/m2K Windows U-Value 1.3 W/m2K Doors (PVC) 2 W/m2K

Space heat generator efficiency Heat pump: 380% min air, 400% ground

Water heat generator efficiency Heat pump: 380% min air, 400% ground

Plus Solar thermal (4m2 to 6m2) 40% contribution of total energy (10% electric immersion)

Heating controls Full zone control Cylinder Insulation 50mm, spray foam Mechanical Heat Recovery Ventilation 80% minimum efficiency

Page 5: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

5

Page 6: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

6

Page 7: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

7

National Energy Efficiency Action Plan 2009 - 2020

Ø  20% reduction in energy use by 2020

Ø  20% national target = 32,000 GWh

Ø  I million building upgrades across residential, commercial & public sector to achieve 8,000 GWh savings

Ø Residential sector savings to be achieved via higher standards for new building, retrofitting older building stock, efficient boiler standards, green technologies and smart metering etc

Page 8: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

8

Government Grants for Retrofits of Privately Owned Houses in Ireland (2011)

Measure Grant Available (2011)

Roof Insulation Ceiling Level

€200 Rafter Level

Wall Insulation

Cavity Fill €250 Dry-lining Insulation Apartment (any) OR Mid-terrace House

€900

Semi-detached or End of Terrace €1,350 Detached House €1,800 External Insulation Apartment (any) OR Mid-terrace House

€1,800

Semi-detached or End of Terrace €2,700 Detached House €3,600

Heating System

High Efficiency Gas Boiler installation with Heating Controls Upgrade

€560 High Efficiency Oil Boiler installation with Heating Controls Upgrade Heating Controls Upgrade Only €400 Solar Heating €800

Building Energy Rating Cert €50 Windows Replace/upgrade existing windows No Grant available

Page 9: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

9

Government Grants for Retrofits of Social Housing

(owned by Local Authorities)

Energy  Saving  per  Year  (kWh/m2/year)   Grant  (lesser  of)  

Minimum  %  from  Local  Authority  

 >300  kWh     90%  or  €18,000   10%  

200-­‐300  kWh     90%  or  €15,500   10%  

100-­‐200  kWh     75%  or  €11,500   25%  

50-­‐100  kWh     50%  or  €6,000   50%  

Page 10: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

10

Refurbishment Rates for Irish Housing Stock (2000-2011)

•     Low  income  homes  received  1  to  2  measures  •     Private  homes  received  2  to  3  measures    •     35,000  houses  also  had  renewable  technology  installa.ons  •     NB:  EPCs  (BERs)  were  issued  for  the  majority  of  these    buildings  

    Low  Income  Homes   Private  Homes   Social  Housing    

2000-­‐2006                                                        11,000            

2007                                                            4,000            

2008                                                            5,000            

2009                                                        15,000     20,000   1,200  

2010                                                        20,000     40,000   1,800  

2011                                                        25,000     50,000   3,000  

Totals                                                        80,000     110,000   6,000  

Page 11: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

11

Comparing TABULA Results to data in SEAI’s Database of 225,00 BERs

TABULA  Type  

Pre-­‐1978  TABULA  House  types  

TABULA  Typical  Primary  Energy  Value  kWh/m2/a  

NaNonal  EPC  Database  Average  Primary  Energy  Value  kWh/m2/a   Varia.on    

Varia.on  as  %  of  TABULA  typical  Primary  Energy  Value  

SEAI  NAS  Max  kWh/m2/a  

SEAI  Min  kWh/m2/a  

1  SFH.01.Gen   484   366   118   24%   8901   75  

2  TH.01.Gen   489   314   175   36%   8031   101  

3  SFH.01.Stone   618   440   178   29%   11824   95  

4  TH.01.Stone   607   410   197   32%   6724   93  

5  SFH.01.225SB   634   443   191   30%   1736   119  

6  TH.01.225SB   464   390   73   16%   5627   119  

7  SFH.01.325SB   454   383   71   16%   2702   110  

8  TH.01.325SB   632   381   250   40%   6484   98  

9  SFH.01.MassConc   657   507   150   23%   15393   121  

1.  BER database includes many houses that have received grant-supported upgrades

2.  TABULA house type are based on one specific fuel type

Source: SEAI, October 2011 G Rating

Page 12: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

12

EPCs Published for Type 1

    Number   Percentage  A1 0   0%  A2 0   0%  A3 0   0%  B1 5   0%  B2 26   0%  B3 73   1%  C1 145   3%  C2 233   4%  C3 352   7%  D1 437   8%  D2 613   12%  E1 470   9%  E2 495   9%  F 718   14%  G 1751   33%  

    5318   100%  

0%

5%

10%

15%

20%

25%

30%

35%

A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G

1. Detached House, stone walls, pre-1978

A1

A2

A3

B1

B2

B3

C1

C2

C3

D1

D2

E1

E2

35% are D2 or better

Page 13: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

13

EPCs Published for Type 2

    Number   Percentage  A1 0   0%  A2 0   0%  A3 0   0%  B1 1   0%  B2 19   0%  B3 71   1%  C1 201   3%  C2 380   6%  C3 561   8%  D1 920   13%  D2 1025   15%  E1 665   10%  E2 759   11%  F 944   14%  G 1351   20%  

    6897   100%  

0%

5%

10%

15%

20%

25%

A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G

2. End of terrace house, stone walls, pre-1978

A1

A2

A3

B1

B2

B3

C1

C2

C3

D1

D2

E1

E2

44% are D2 or better

Page 14: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

14

External Insulation in 2011 in Tralee, Co Kerry

Area-­‐based  project  led  by  Electric  Ireland    80  houses  refurbished  with  external  wall  insula.on  and  roof  insula.on  2011/2012    All  will  connect  to  new  wood  chip  boiler  district  hea.ng  system  in  2012    

Photos courtesy of Electric Ireland

Page 15: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

15

EPCs Published for Type 10

    Number   Percentage  A1 0   0%  A2 0   0%  A3 6   0%  B1 54   1%  B2 124   2%  B3 291   4%  C1 443   6%  C2 644   9%  C3 828   12%  D1 1168   17%  D2 1160   17%  E1 648   9%  E2 530   8%  F 529   8%  G 414   6%  

    6839   100%  0%

2%

4%

6%

8%

10%

12%

14%

16%

18%

A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G

Semi detached, hollow block walls, pre-1978

A1

A2

A3

B1

B2

B3

C1

C2

C3

D1

D2

E1

69% are D2 or better

Page 16: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

16

EPCs Published for Type 11

0%

2%

4%

6%

8%

10%

12%

14%

16%

A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G

Terraced house, hollow block walls pre-1978

A1

A2

A3

B1

B2

B3

C1

C2

C3

D1

    Number   Percentage  A1 0   0%  A2 0   0%  A3 0   0%  B1 20   1%  B2 40   2%  B3 83   5%  C1 129   7%  C2 151   9%  C3 192   11%  D1 235   14%  D2 249   14%  E1 170   10%  E2 160   9%  F 147   8%  G 163   9%  

    1739   100%  

64% are D2 or better

Page 17: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

17

External Insulation in last 3 years on same street

Individual  home-­‐owners  had  EWI  installed    All  availed  of  energy  efficiency  grant  support      9  homes  on  the  same  street  so  far  

Page 18: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

18

EPCs Published for Type 12

0%

2%

4%

6%

8%

10%

12%

14%

16%

18%

A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G

12. Detached House, cavity walls pre-1978

A1

A2

A3

B1

B2

B3

C1

C2

C3

D1

D2

E1

    Number   Percentage  A1 0   0%  A2 1   0%  A3 37   0%  B1 125   1%  B2 377   2%  B3 1445   8%  C1 2257   12%  C2 2856   15%  C3 3157   16%  D1 3044   16%  D2 2560   13%  E1 1130   6%  E2 776   4%  F 696   4%  G 768   4%  

    19229   100%  

The  most  recent  update  of  the  Irish  EPC  sobware  (December  2011)  includes  data  on  the  purpose  of  the  EPC  cer.ficate  

Page 19: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

19

EPCs Published for Type 13     Number   Percentage  

A1 0   0%  A2 0   0%  A3 29   0%  B1 194   1%  B2 492   2%  B3 1707   6%  C1 3199   11%  C2 4107   14%  C3 4941   17%  D1 5038   17%  D2 4015   14%  E1 2077   7%  E2 1469   5%  F 1297   4%  G 1026   3%  

    29591   100%  

0% 2% 4% 6% 8%

10% 12% 14% 16% 18%

A1 A2 A3 B1 B2 B3 C1 C2 C3 D1 D2 E1 E2 F G

13. End Terrace house, cavity walls, pre-1978

A1

A2

A3

B1

B2

B3

C1

C2

Summary:  1.  EPC  database  is  strongly  influenced  by  refurbished  buildings  so  

be  careful  in  drawing  conclusions  from  EPC  database  2.  The  EPC  scores  of  refurbished    buildings  correspond  to  TABULA  

refurbishment  steps      3.  The  TABULA  brochures  will  contribute  posi.vely  to  na.onal  

retrofit  programmes

Page 20: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

20

So do typology results & studies contribute to Retrofit Programmes?

Ø  The response from Irish homeowners, building energy experts and the retrofit industry to the typology brochures has been enthusiastic

Ø  There is significant demand to expand & refine the Irish typology as the National Retrofit progamme develops out to 2020

Ø Draft of new Code of Practice (COP) for Retrofitting of Dwellings will issue from the Department of Environment in March 2012. Three building types from the Irish TABULA project are included in the COP.

Page 21: The Irish TABULA Project - Österreichische Energieagentur · 2012. 8. 16. · 3. The!TABULA!brochures!will!contribute!posi.vely!to!naonal! retrofit programmes. 20 So do typology

21

Irish Project

"The sole responsibility for the content of this presentation lies with the authors. It does not represent the opinion of the Community. The European Commission is not responsible for any use that may be made of the information contained therein."

Thank you for your attention