the i dea m akes i deal yl6500 gc. 680a m600d yl6100 the history of gc development 1991 1995 acme...

26
THE iDEA MAKES iDEAL YL6500 GC YL6500 GC

Upload: courtney-ferriss

Post on 31-Mar-2015

218 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

THE iDEA MAKES iDEAL

YL6500 GCYL6500 GC

Page 2: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

680A

M600D

YL6100

The History of GC DevelopmentThe History of GC Development

1991

1995Acme 6000

2001

2006

2011INNOVATIVE YL6500GC

Page 3: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC FeaturesYL6500 GC Features

YL6500GC comes with Enhanced 4 Vs

• View

• Verification

• Variety

• Value

Page 4: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC FeaturesYL6500 GC Features

Enjoy the View• Enlarged Haptic color LCD(5.7”)

showing all factors at a glance.

•Classic and lab-suitable Design

•Intuitive and user-friendly view by

YL chromatography data system

Page 5: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC FeaturesYL6500 GC Features

Reliable Verification• Strongly Enhanced APCs for almost all detectors

- Increased precision in pressure and flow rate

- Automatic compensation for temperature & pressure in installation condition

- Pressure setpoint increment : 0.01 psi /Pressure stability : ±0.001 psi

- Shockproof APCs with short flow length

- 4 column flow control modes: constant pressure, constant flow,

programmed pressure (5 steps), programmed flow (5 steps).

- Stable APCs against oven temperature changes

- Up to six APCs can be installed and up to 18 channels of APC.

Page 6: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC FeaturesYL6500 GC Features

Reliable Verification: (1) Reproducibility Test

Page 7: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC FeaturesYL6500 GC Features

Reliable Verification: (2) Complex Analysis

Accurate & Precise Valve Switching Time Increment

: 0.01 min

* Accurate control of valve switching time in settable point up to 0.01 min allows analyzing complex samples containing various components that can not be separated by one column or detected by one detector reversing column flow precisely(Backflush) with no loss of peak area values.

<Analysis of oxygenates in diesel>

Page 8: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC FeaturesYL6500 GC Features

Reliable Verification• High speed data process by network (LAN) communication

• Ten heated Zones to enhance a precision

: 1 heated oven zone/ 3 heated injector zone

3 heated detector zone/ 2 heated valve zone

1 heated methanizer zone

• Powerful and easy control by YL chromatography software

Page 9: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC FeaturesYL6500 GC Features

Wide Variety• Maximum no. of inlet / detector to be installed : 3

• Various inlets available

- Capillary Inlet

- Packed Inlet

- On-Column Inlet (Temperature programming up to 5 steps)

Page 10: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC FeaturesYL6500 GC Features

Wide Variety• Various detectors with high sensitivity available

- Flame Ionization Detector (FID) : MDL < 2.0 pg C/sec

- Thermal Conductivity Detector (TCD) : MDL < 2.5 ng /ml

- Micro- Thermal Conductivity Detector (μTCD) : MDL < 400 pg/ml

- Nitrogen Phosphorus Detector(NPD)

- Flame Photometric Detector (FPD)

- Electron Capture Detector(ECD) : MDL < 10 fg/sec

- Pulsed discharge Detector (PDD)

- Pursed Frame Photometric Detector (PFPD)

Page 11: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC FeaturesYL6500 GC Features

Upgrade the Value• Reasonable price saving user’s valuable time

• Improved column conditioning function

: Automatic set of split flow up to 5ml/min on column conditioning

• Sensitive leak detection (H2)

• Prevention of oven malfunction (Over heating)

• Automatic stop when an oven door gets opened during

operation.

• Time control: Automatic turn-on/off

Page 12: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Superior Performance in Column Oven• Usable volume : 14L

• Temperature operating range : (ambient to 450 or more) ℃ : - 80 ~ 450 (with LN℃ ℃ 2 cryogenic cooling)

: - 55 ~ 450 (with CO℃ ℃ 2 cryogenic cooling)

• Temperature set-point : 1℃• Programming: 25 ramps, 26 steps temperature program

• Maximum set-point heating rate: 100 /min℃•Temperature program method: Maximum up to 20

•Temperature stability : ±0.01 (Isothermal)℃

Page 13: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Enhanced Performance in Inlets• Packed inlet

- Maximum Temperature : 450 ℃

- Pressure setting range : 0.01 ~ 100 psi

- Total flow setting range : 0.1~100 ml/min

- Flow stability < ±0.05ml/min

- Pressure stability < ± 0.05psi

- Temperature setpoint : 1 ℃

- Temperature stability < ±0.1 ℃

Page 14: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Enhanced Performance in Inlets• Capillary inlet (Split/Splitless) - Maximum temperature : 400℃

- Pressure setting range : 0.01 ~ 100 psi

- Total flow setting range : 0.1 ~ 400 ml/min N2

0 ~ 1000ml/min He

- Splitless time setpoint : 0.01min

- Total flow stability < ±0.05ml/min

- Pressure stability < ± 0.05psi

- Temperature setpoint : 1 ℃

- Temperature stability < ±0.1 ℃

Page 15: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Enhanced Performance in Inlets• On-column Inlet - Maximum Temperature : 450 ℃

- Pressure setting range : 0.01 ~ 100 psi

- Total flow setting range : 0.1 ~ 100 ml/min

- Flow stability < ±0.05ml/min

- Pressure stability < ± 0.05psi

- Temperature setpoint : 1 ℃

- Temperature stability < ±0.1 ℃

- Temperature programming up to 5 steps

Page 16: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Exceptional Sensitivity in Detectors• Flame Ionization Detector- Maximum operating temperature : 450 ℃

- Automatic flame ignition

- Temperature set-point : 1 ℃

- Ignition message: Alarm message as ‘Flame out’

- MDL : 2.0 pg carbon/sec

- Linear dynamic range : 107

-Temperature stability : ± 0.1℃

- Data acquisition rate : 200 Hz

Page 17: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Analysis condition-Column: Innowax, 30m x 0.32mm x 0.5um -Oven: 100℃(5min) 4℃/min 240℃ (10min) -Injector : 250℃-Detector : 280 ℃

* Fatty Acid Methyl Esters Analysis by FID

Page 18: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Exceptional Sensitivity in Detectors• Thermal Conductivity Detector- Maximum operating temperature : 400 ℃

- Flow through cell : 4 Rhenium-Tungsten filaments

- Temperature set-point : 1 ℃

- Filament protection

- MDL : 2.5 ng/ml

- Micro-cell (Option) : μTCD (MDL < 400 pg/ml)

- Data acquisition rate : 200 Hz

Page 19: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Analysis ConditionOven : 35 ℃(5min) →10 ℃/min →225 ℃(5min)Column : Carboxen1000, 1/8", 15ft, 60/80 mesh Carrier gas : He, 25 ml/min Injector : 120°CDetector : TCD(120℃), Sens 6Injection Volume : 1ml

* Carboxen 1000 Analysis by TCD

Page 20: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Exceptional Sensitivity in Detectors• Electron Capture Detector

- Maximum operating temperature : 400 ℃

- MDL : 10 fg/sec

- Dynamic Range : > 104

- Radionuclide(Estimated Content Activity) : Ni-63 (555 MBq)

Page 21: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

* Residual pesticides Analysis by ECDAnalysis ConditionColumn: HP-5 30m x 0.32mm x 0.25um Oven: 80 (2min) - 10 /min - 280 (8min) ℃ ℃ ℃Injector: 280℃Detector: 300 , ℃Make up gas: 40ml/min

Page 22: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Exceptional Sensitivity in Detectors• Nitrogen Phosphorous Detector

- Maximum operating temperature : 400 ℃

- MDL : <0.4 pg N/sec (Azobenzene)

<0.2 pg P/sec (Malathion)

- Dynamic Range for N : > 104

- Dynamic Range for P : > 104

Page 23: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Exceptional Sensitivity in Detectors• Flame Photometric Detector - Maximum operating temperature : 300 ℃

- Minimum detection limit for S : < 20 pg S/sec

- Minimum detection limit for P : < 0.5 pg P/sec

- Dynamic Range for S : > 103

- Dynamic Range for P : > 104

- S/C Selectivity : 105

- P/C Selectivity : 106

Page 24: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

YL6500 GC ModulesYL6500 GC Modules

Exceptional Sensitivity in Detectors• Pulsed Discharge Detector - Maximum operating temperature : 400 ℃

- PDHID, PDECD mode is selectable

- Helium ionization mode(PDHID) : Linearity – 105

MDL (organic compound : low ppb)

(permanent gas : low ppm)

- Electron capture mode(PDECD) : Linearity – 105

MDL – 10-15

Dopant gas : 3% Xe in Helium

Page 25: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

• Specifications of YL6500GC VS “A” company

YL6500GC “A” 7890A

Max. Number of Heated Zones 10 7

Max. Number of Inlet 3 2Max. Number of Detectors 3 3 (3rd detector as TCD)Max. GC Methods Storage 20 5

Max. Programming Ramp/Plateaus 25/26 20/21

Max. Channels of APC 18 16

FID MDL 2.0 pg carbon/sec as dodecane using N2 carrier

1.8 pg C/s (for tridecane)

TCD MDL 2.5 ng/ml as dodecaneμTCD : 0.4 ng/ml

0.4 ng tridecane/mLwith He carrier

ECD MDL <10 fg/sec as Lindane <6 fg/mL Lindane

YL6500 GC CompetitionYL6500 GC Competition

Page 26: THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC

• Specifications of YL6500GC VS “P” company

YL6500GC “P” Clarus 680

Max. Number of Heated Zones 10

Max. Number of Inlet 3 2

Max. Number of Detectors 3 2

Max. GC Methods Storage 20 5

Max. Programming Ramp/Plateaus 25/26 9/10

Max. Channels of APC 18 12

FID MDL 2.0 pg carbon/sec as dodecane using N2 carrier

3 pg C/s (for tridecane)

TCD MDL 2.5 ng/ml as dodecaneμTCD : 0.4 ng/ml

1000 ng/mL nonane

ECD MDL <10 fg/sec as Lindane < 0.05 pg nitrogen

YL6500 GC CompetitionYL6500 GC Competition