the hermes recoil detector - gsi...
TRANSCRIPT
![Page 1: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/1.jpg)
The HERMES Recoil Detector
Inti Lehmann
University of Glasgow
for the HERMES Collaboration
EuNPC Bochum, 17 March 2009
![Page 2: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/2.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 2
Nucleon Structure
• Proton spin
• : quark spin
about 1/3 (HERMES,...)
• Lq : quark angularmomentum
unknown
• Jg : gluon total angularmomentum
unknown
• How is the spin distributed?
![Page 3: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/3.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 3
Access Nucleon Structure
• Ji Sum Rule
• Functions of 3 variables
parton momentum
fraction x
skewedness
p momentum transfer t
Generalised Parton
Distributions (GPDs)
Deeply Virtual Compton
Scattering (DVCS)
Final state: e, , p
![Page 4: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/4.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 4
HERMES at HERA, DESY
• Long. polarized
electron/positron
beams 27.6 GeV
![Page 5: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/5.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 5
HERMES at HERA, DESY
Magnetic spectrometer with transv. and long. polarized targets
![Page 6: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/6.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 6
Measurement of Recoiling Proton
• Remove background from associated BH/DVCS withintermediate -production and from semi-inclusive
processes
Reduction from 17% to about 1%
• Improve t-resolution at small t (with Si-detector)
• High luminosity with unpolarised targets
e p e X e p e p
![Page 7: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/7.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 7
HERMES with Recoil
![Page 8: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/8.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 8
HERMES Recoil Detector
• 2 magnetic
spectrometer
surrounding
target
• Unpolarised
gas targets
H, D
• Challenging
conditions
Inside magnet
Close to e+/e-
beamsolenoid
target cell
silicon-strip
detectors
fibre trackers
photon detector
e beam
![Page 9: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/9.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 9
Silicon Strip Detector
• Purposedetect 125-500 MeV/cprotons
Momentum and trackreconstruction
Particle Identification
• 16 silicon sensors:10 x 10 cm2 area
300um thickness
double-sided strips
• Arranged in 2 layers
• ChallengeDetector + electronicsclose to e beam
Inside vacuum
![Page 10: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/10.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 10
Scintillating Fibre Detector
• Purpose
Momentum and track
reconstruction
Particle Identification
Range: pp = 250-1200 MeV/c
• 2 barrels with each:
2 layers parallel with
respect to the beam
2 layers 10° stereo angle
6910 fibres
• Readout:
64 channels PMT
(Hamamatsu)
totally 5120 channels
![Page 11: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/11.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 11
Photon Detector
• Purposes
Photon detection from° decays ( + p °
p )
Particle Identification
Background reduction
• 3 layers of tungsten
and scintillator
1st layer parallel to
beam
2nd layer +45° resp. to
beam
3rd layer -45° resp. to
beam
![Page 12: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/12.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 12
Performance
Energy deposit in silicon detectors
on a deuterium target
• Examples
Residuals show precise alignment
Efficiency for protons (e.g. 1 side, sensor)
![Page 13: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/13.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 13
Performance
• Particle
identification
momentum =
curvature
E in each
layer
(independent)
![Page 14: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/14.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 14
Event Selection
• First comparison
Traditional criteria adding Recoil information
DVCS analysis exclusive analysis
exclusive 0 analysis
![Page 15: The HERMES Recoil Detector - GSI Wikiweb-docs.gsi.de/~ilehmann/pub/talks/09/HermesRecoil0903_Bochum.ppt.pdfThe HERMES Recoil Detector Inti Lehmann University of Glasgow for the HERMES](https://reader030.vdocuments.mx/reader030/viewer/2022041209/5d672f4b88c99389108b6069/html5/thumbnails/15.jpg)
17/03/2009 EuNPC I. Lehmann, HERMES Recoil Detector 15
Summary
• About 40M DIS events on hydrogen collected in
2006/2007
More than in 10 years before (without Recoil)
• Detector status
Alignment and calibration finished
Detailed response studies ongoing
First physics analysis starting
• Preliminary results promising
• See HERMES talks on Thursday: HK 70
• Results expected soon