the good shepherd foundation unit - st anne's building ... · design bending moment; m = max(abs(m...

18
The Good Shepherd Foundation Unit - St Anne's Building Structural Report

Upload: others

Post on 23-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

  • The Good Shepherd Foundation Unit - St Anne's Building

    Structural Report

  • Tunstall Smith King Limited

    29 Stoney Street

    Nottingham, NG1 1LP

    T: 0115 922 9863

    E: [email protected]

    W: tskconsulting.co.uk

    Registered in England and Wales

    Registered Number: 9640811

    Registered Office: 129a Middleton Boulevard,

    Wollaton Park, Nottingham, NG8 1FW

    Company Directors:

    Garry Tunstall BEng (Hons) CEng MIStructE

    Peter Smith BEng (Hons) CEng MIStructE

    Stephen King BEng (Hons) CEng MIStructE

    The Good Shepherd Catholic Academy

    Structural Calculations

    Job number. 220062 Status: C1

    Revision: C1 Date: May 20

  • Project: 220086

    Structural Calculations i Tunstall Smith King Limited

    Document Control

    Revision C1 Date 21/05/20 Prepared By JS Checked By GT

    Remarks: Building Control Submission

  • Project: 220086

    Structural Calculations ii Tunstall Smith King Limited

    Contents

    1.0 Introduction Page 1

    2.0 Proposed Works Page 1

    3.0 Design Codes and Software Page 1

    4.0 Calculations Page 2

  • Project: 220086

    Structural Calculations 1 Tunstall Smith King Limited

    1.0 Introduction Tunstall Smith King have been appointed to carry out the structural design requirements to enable the removal of a load bearing wall at the Good Shepherd Catholic Academy School in Woodthorpe, Nottingham. The site address is: The existing school is a traditional single storey masonry building with the pitched roof comprising timber trusses battens and tiles.

    2.0 Proposed Works

    It is proposed that the school is altered internally to provide a layout that better fulfils the schools needs. This includes the removal of both non-loadbearing and loadbearing walls with the addition of new partitions to create the desired layout.

    3.0 Design Codes and Software Design Codes BS 5950: Part 1: 2000 Structural use of steelwork. Part 1: Code of practice for rolled sections and

    welded sections BS 6399: Part 1: 1996 BS 6399: Part 3: 1988

    Loading for buildings. Part 1: Code of practice for dead & imposed loads. Loadings for buildings. Part 3: Code of practice for imposed roof loads.

    BS 8110: Part 1: 1997 Structural use of concrete. Part 1: Code of practice for design and construction.

  • Project: 220086

    Structural Calculations 2 Tunstall Smith King Limited

    4.0 Calculations

  • 2No. 203x133x25 UB'S BOLTEDTOGETEHR WITH TUBULAR SPACERSAND M12 BOLTS @ 450 CENTRES

    TO REDUCE THE NUMBEROF PROPS REQUIRED,PROP ONE SIDE OF THEROOF FIRST AND INSTALLTHE CORRESPONDINGBEAM, REMOVE PROPSONCE BEAM IN PLACE ANDREPEAT TO THE OTHERSIDE OF THE ROOF.

    PROVIDE NEW JOISTHANGER TO FIX TRUSS TOADJACENT GIRDER PRIORTO REMOVING MASONRYWALL

    ROOF TRUSS APPEARS TOBE PACKED TIGHTLY TOWALL PROPOSED TO BEREMOVED.

    EXIS

    TING

    GIR

    DER

    TRUS

    S

    SPAN OFEXISTING ROOFTRUSSES

    SECTION THROUGH RETAINING WALL

    revision

    drawndatescale (s)

    projectsketch title

    P1

    JSMay / 20201:50 @ A3

    Ground floor plan showing structure over The Good Shepherd Catholic Academy

    rev date by chk descriptionP1 20/05/20 JS GT Preliminary

    drawing status

    Preliminaryproject no.

    220062

    This drawing is to be read in conjunction with all relevant architects,engineers and specialist drawings and specifications.

    Do not scale from this drawing.

    drawing no.

    S/1000

    PROVIDE MASONRYPADSTONE - 225 LONG X225 DEEP (3No. COURSES)WITH 150mm BEARINGFROM BEAM

    PROVIDE MASONRYPADSTONE - 225 LONG X225 DEEP (3No. COURSES)WITH 150mm BEARINGFROM BEAM

  • 220062

  • TSK Consulting

    37 Wollaton Road

    Beeston

    NG9 2NG

    Project

    The Good Shepherd Catholic Academy

    Job no.

    220062

    Calcs for

    Beam Design

    Start page no./Revision

    1

    Calcs by

    JS

    Calcs date

    20/05/2020

    Checked by Checked date Approved by Approved date

    STEEL BEAM ANALYSIS & DESIGN (BS5950)

    In accordance with BS5950-1:2000 incorporating Corrigendum No.1

    TEDDS calculation version 3.0.07

    Load Envelope - Combination 1

    0.0

    12.645

    mm 3800

    1A B

    Bending Moment Envelope

    0.0

    22.823

    kNm

    mm 3800

    1A B

    22.8

    Shear Force Envelope

    0.0

    24.025

    -24.025

    kN

    mm 3800

    1A B

    24.0

    -24.0

    Support conditions

    Support A Vertically restrained

    Rotationally free

    Support B Vertically restrained

    Rotationally free

    Applied loading

    Beam loads Dead self weight of beam × 1 Dead full UDL 4.5 kN/m

    Imposed full UDL 3.75 kN/m

    Load combinations

    Load combination 1 Support A Dead × 1.40

    Imposed × 1.60

    Dead × 1.40

    Imposed × 1.60

    Support B Dead × 1.40

    Imposed × 1.60

  • TSK Consulting

    37 Wollaton Road

    Beeston

    NG9 2NG

    Project

    The Good Shepherd Catholic Academy

    Job no.

    220062

    Calcs for

    Beam Design

    Start page no./Revision

    2

    Calcs by

    JS

    Calcs date

    20/05/2020

    Checked by Checked date Approved by Approved date

    Analysis results

    Maximum moment; Mmax = 22.8 kNm; Mmin = 0 kNm

    Maximum shear; Vmax = 24 kN; Vmin = -24 kN

    Deflection; δmax = 4.8 mm; δmin = 0 mmMaximum reaction at support A; RA_max = 24 kN; RA_min = 24 kN

    Unfactored dead load reaction at support A; RA_Dead = 9 kN

    Unfactored imposed load reaction at support A; RA_Imposed = 7.1 kN

    Maximum reaction at support B; RB_max = 24 kN; RB_min = 24 kN

    Unfactored dead load reaction at support B; RB_Dead = 9 kN

    Unfactored imposed load reaction at support B; RB_Imposed = 7.1 kN

    Section details

    Section type; UKB 203x133x25 (Tata Steel Advance)

    Steel grade; S275

    From table 9: Design strength py

    Thickness of element; max(T, t) = 7.8 mm

    Design strength; py = 275 N/mm2

    Modulus of elasticity; E = 205000 N/mm2

    133.2

    5.7

    20

    3.2

    7.8

    7.8

    Lateral restraint

    Span 1 has lateral restraint at supports only

    Effective length factors

    Effective length factor in major axis; Kx = 1.00

    Effective length factor in minor axis; Ky = 1.00

    Effective length factor for lateral-torsional buckling; KLT.A = 1.20; + 2 × D

    KLT.B = 1.20; + 2 × D

    Classification of cross sections - Section 3.5

    ε = √[275 N/mm2 / py] = 1.00

    Internal compression parts - Table 11

    Depth of section; d = 172.4 mm

    d / t = 30.2 × ε

  • TSK Consulting

    37 Wollaton Road

    Beeston

    NG9 2NG

    Project

    The Good Shepherd Catholic Academy

    Job no.

    220062

    Calcs for

    Beam Design

    Start page no./Revision

    3

    Calcs by

    JS

    Calcs date

    20/05/2020

    Checked by Checked date Approved by Approved date

    Outstand flanges - Table 11

    Width of section; b = B / 2 = 66.6 mm

    b / T = 8.5 × ε λL0 - Allowance should be made for lateral-torsional buckling

    Bending strength - Section 4.3.6.5

    Robertson constant; αLT = 7.0

    Perry factor; ηLT = max(αLT × (λLT - λL0) / 1000, 0) = 0.509

    Euler stress; pE = π2 × E / λLT2 = 176.4 N/mm2

    φLT = (py + (ηLT + 1) × pE) / 2 = 270.7 N/mm2

    Bending strength - Annex B.2.1; pb = pE × py / (φLT + (φLT2 - pE × py)0.5) = 113.4 N/mm2

    Equivalent uniform moment factor - Section 4.3.6.6

    Moment at quarter point of segment; M2 = 17.1 kNm

    Moment at centre-line of segment; M3 = 22.8 kNm

    Moment at three quarter point of segment; M4 = 17.1 kNm

    Maximum moment in segment; Mabs = 22.8 kNm

    Maximum moment governing buckling resistance; MLT = Mabs = 22.8 kNm

    Equivalent uniform moment factor for lateral-torsional buckling;

    mLT = max(0.2 + (0.15 × M2 + 0.5 × M3 + 0.15 × M4) / Mabs, 0.44) = 0.925

    Buckling resistance moment - Section 4.3.6.4

    Buckling resistance moment; Mb = pb × Sxx = 29.2 kNmMb / mLT = 31.6 kNm

    PASS - Buckling resistance moment exceeds design bending moment

  • TSK Consulting

    37 Wollaton Road

    Beeston

    NG9 2NG

    Project

    The Good Shepherd Catholic Academy

    Job no.

    220062

    Calcs for

    Beam Design

    Start page no./Revision

    4

    Calcs by

    JS

    Calcs date

    20/05/2020

    Checked by Checked date Approved by Approved date

    Check vertical deflection - Section 2.5.2

    Consider deflection due to dead and imposed loads

    Limiting deflection;; δlim = min(15 mm, Ls1 / 360) = 10.556 mm

    Maximum deflection span 1; δ = max(abs(δmax), abs(δmin)) = 4.808 mmPASS - Maximum deflection does not exceed deflection limit

  • TSK Consulting

    37 Wollaton Road

    Beeston

    NG9 2NG

    Project

    The Good Shepherd Catholic Academy

    Job no.

    220062

    Calcs for

    Masonry Bearing Design

    Start page no./Revision

    1

    Calcs by

    JS

    Calcs date

    20/05/2020

    Checked by Checked date Approved by Approved date

    MASONRY BEARING DESIGN TO BS5628-1:2005

    TEDDS calculation version 1.0.06

    Masonry details

    Masonry type; Aggregate concrete blocks (25% or less formed voids)

    Compressive strength of unit; punit = 3.6 N/mm2

    Mortar designation; iii

    Least horizontal dimension of masonry units; lunit = 100 mm

    Height of masonry units; hunit = 215 mm

    Category of masonry units; Category II

    Category of construction control ; Normal

    Partial safety factor for material strength; γm = 3.5Thickness of load bearing leaf; t = 100 mm

    Effective thickness of masonry wall; tef = 133 mm

    Height of masonry wall; h = 2500 mm

    Effective height of masonry wall; hef = 2500 mm

    B

    Beam to span in plane of wall

    Spreader

    hs

    t

    lb

    ls

    Bearing details

    Beam spanning in plane of wall

    Width of bearing; B = 100 mm

    Length of bearing; lb = 150 mm

    Compressive strength from Table 2 BS5628:Part 1 - aggregate concrete blocks (25% or less formed voids)

    Mortar designation; Mortar = "iii"

    Block compressive strength; punit = 3.6 N/mm2

    Characteristic compressive strength (Table 2c); fkc = 1.70 N/mm2

    Characteristic compressive strength (Table 2d); fkd = 3.50 N/mm2

    Height of solid block; hunit = 215.0 mm ;

    Least horizontal dimension; lunit = 100.0 mm

    Block ratio; ratio = hunit / lunit = 2.2

  • TSK Consulting

    37 Wollaton Road

    Beeston

    NG9 2NG

    Project

    The Good Shepherd Catholic Academy

    Job no.

    220062

    Calcs for

    Masonry Bearing Design

    Start page no./Revision

    2

    Calcs by

    JS

    Calcs date

    20/05/2020

    Checked by Checked date Approved by Approved date

    Ratio between 0.6 and 4.5 - OK

    Characteristic compressive strength; fk = 3.50 N/mm2

    Loading details

    Characteristic concentrated dead load; Gk = 9 kN

    Characteristic concentrated imposed load; Qk = 7 kN

    Design concentrated load; F = (Gk × 1.4) + (Qk × 1.6) = 23.8 kNCharacteristic distributed dead load; gk = 4.5 kN/m

    Characteristic distributed imposed load; qk = 3.8 kN/m

    Design distributed load; f = (gk × 1.4) + (qk × 1.6) = 12.3 kN/m

    Masonry bearing type

    Bearing type; Type 2

    Bearing safety factor; γbear = 1.50

    Check design bearing without a spreader

    Design bearing stress; fca = F / (B × lb) + f / t = 1.710 N/mm2

    Allowable bearing stress; fcp = γbear × fk / γm = 1.500 N/mm2

    FAIL - Design bearing stress exceeds allowable bearing stress, use a spreader

    Spreader details

    Length of spreader; ls = 225 mm

    Depth of spreader; hs = 215 mm

    Edge distance; sedge = max(0 mm, xedge – (ls - B) / 2) = 0 mm

    Spreader bearing type

    Bearing type; Type 3

    Bearing safety factor; γbear = 2.00

    Check design bearing with a spreader

    Loading acts eccentrically - stress distribution similar to semi-infinite beam on elastic foundation

    Modulus of elasticity of masonry wall; Ew = 700 × fk = 2.5 kN/mm2

    Modulus of elasticity of spreader beam; Eb = 30 kN/mm2

    Modulus of wall; k = Ew / h = 1.0 N/mm3

    Moment of inertia of spreader beam; Ib = t × hs3 / 12 = 82.8×106 mm4

    Constant; γ = (t × k / (4 × Eb × Ib))1/4 = 1.77×10-3 mm-1

    Classification of spreader; γ × ls = 0.40Short

    WARNING! - γ × ls

  • WET AREA

    VERANDAH

    RECEPTION CLASS

    TOILETS

    STAFF / Baby Change

    STORE

    KITCHEN / UTIL

    COAL STORE

    CLASSROOM

    BOILERS

    CUP'D

    QUIET ROOM

    RESOURCE

    STORE

    MEETING

    ROOM /

    SEN

    LIBRARY

    FE- CUP'D

    MALE

    CLOAKS

    PRACTICAL AREA

    CLASSROOMCLASSROOM

    MALE

    CLASSROOM

    QUIET AREA

    QUIET AREA

    ST ANNE'S BLOCK

    CLASSROOM

    Decorations & Flooring

    Key

    Walls to be removed

    New partitions

    Decorations

    Flooring

    Doors (2nr in total)

    WET AREA

    VERANDAH

    RECEPTION CLASS

    TOILETS

    STAFF / Baby Change

    STORE

    KITCHEN / UTIL

    COAL STORE

    CLASSROOM

    BOILERS

    CUP'D

    QUIET ROOM

    RESOURCE

    STORE

    MEETING

    ROOM /

    SEN

    LIBRARY

    FE- CUP'D

    MALE

    CLOAKS

    PRACTICAL AREA

    CLASSROOMCLASSROOM

    MALE

    CLASSROOM

    QUIET AREA

    QUIET AREA

    ST ANNE'S BLOCK

    CLASSROOM

    Door and partition to be removed.

    Walls and ceiling are to repaired.

    Floor is to be jointed / thershold strip installed.

    Existing wash station to be removed and disposed

    External door set to be removed and back filled

    in accordance to specification.

    Existing partition to be removed, including fixtures and

    fixings, door is to be removed and back filled in accordance

    with the specification, ceiling to be repaired

    (pattress and painted)

    Existing walls to be removed, allow for works identified

    within structural engineers reports.

    All existing fixtures and fixings are to be removed carefully

    and disposed.

    Proposals & General Notes

    New privacy screen, including cubicles, WC, WHB,

    all in accordance with specification

    Mechanical & Electrical alterations will be required,

    this to be contractor design for this element.

    Requirements have been stipulated within the

    Schedule of Work.

    Storeroom

    P r e l i m i n a r yF o r A p p r o v a l

    T e n d e r I s s u eC o n s t r u c t i o n I s s u e

    P l a n n i n g I s s u e B u i l d i n g R e g . I s s u e

    A s B u i l t

    © copyright

    D r a w i n g I s s u e N o t e s :

    R e v I s s u e D a t e R e v i s i o n N o t e s :

    R e v i s i o n

    P r o p e r t y R e f

    D r a w i n g N o .

    D r a w i n g T i t l e

    D a t e

    S c a l e

    D r a w n

    P r o j e c t

    C h e c k e d

    G e n e r a l N o t e s

    F u r n i t u r e L a y o u t I s s u e

    The Good Shepherd, St Anne's Building Alterations

    The Good Shepherd, St Anne's

    Proposed Works,

    2213-502-1201

    29/04/2020

    A3 @ 1:200

    JE

    HR

    A **/**/**** XXXXXXXXXXXXXXXXXXXX

    Copyright of this drawing belongs to Make Consulting and its

    subsidiary and associated companies and no part thereof may be

    reproduced or utilised in any way whatsoever without the prior written

    consent of Make Consulting.

    DO NOT SCALE

    Figured dimensions shall be taken in preference to scaled

    dimensions and any discrepancies or errors are to be referred to the

    Designer. Contractors, sub-contractors and suppliers must verify all

    dimensions on site before commencing work or making any

    fabrication drawings.

  • 2No. 203x133x25 UB'S BOLTEDTOGETEHR WITH TUBULAR SPACERSAND M12 BOLTS @ 450 CENTRES

    TO REDUCE THE NUMBEROF PROPS REQUIRED,PROP ONE SIDE OF THEROOF FIRST AND INSTALLTHE CORRESPONDINGBEAM, REMOVE PROPSONCE BEAM IN PLACE ANDREPEAT TO THE OTHERSIDE OF THE ROOF.

    PROVIDE NEW JOISTHANGER TO FIX TRUSS TOADJACENT GIRDER PRIORTO REMOVING MASONRYWALL

    ROOF TRUSS APPEARS TOBE PACKED TIGHTLY TOWALL PROPOSED TO BEREMOVED.

    EXIS

    TING

    GIR

    DER

    TRUS

    S

    SPAN OFEXISTING ROOFTRUSSES

    SECTION THROUGH RETAINING WALL

    revision

    drawndatescale (s)

    projectsketch title

    P1

    JSMay / 20201:50 @ A3

    Ground floor plan showing structure over The Good Shepherd Catholic Academy

    rev date by chk descriptionP1 20/05/20 JS GT Preliminary

    drawing status

    Preliminaryproject no.

    220062

    This drawing is to be read in conjunction with all relevant architects,engineers and specialist drawings and specifications.

    Do not scale from this drawing.

    drawing no.

    S/1000

    PROVIDE MASONRYPADSTONE - 225 LONG X225 DEEP (3No. COURSES)WITH 150mm BEARINGFROM BEAM

    PROVIDE MASONRYPADSTONE - 225 LONG X225 DEEP (3No. COURSES)WITH 150mm BEARINGFROM BEAM