the gold standard in stereotactic biopsybrownsmedicalimaging.com/wp-content/uploads/hologic... ·...
TRANSCRIPT
The MultiCare® Platinum prone stereotactic breast biopsy system offers exceptional image
quality and precise, effi cient operation using leading-edge targeting and guidance technology.
The MultiCare system features our exclusive contoured surface with centered aperture to
optimize effi ciency. Our C-arm can be positioned at any angle, providing true 360 degree
access to ensure easy access with the shortest skin-to-lesion distance, allowing direct access
to inferior lesions.
The MultiCare system is designed to provide enhanced patient comfort, effi cient space
utilization, and ease of operator use. The space-effi cient design allows installation within 15
inches from the wall, optimizing use of existing space. In addition to providing you effi cient and
precise breast biopsy technology, we also understand that patient care and comfort is a major
concern. Hologic has developed the MultiCare Maximum Comfort Package, offering a collection
of ergonomically engineered cushions that provide targeted pressure point support for all body
types and lesions.
B R E A S T I M A G I N G S O L U T I O N S
The Gold Standard in Stereotactic Biopsy
BREAST IMAGING SOLUTIONS | INTERVENTIONAL BREAST SOLUTIONS | BONE HEALTH
PRENATAL HEALTH | GYNECOLOGIC HEALTH | MOLECULAR DIAGNOSTICS
DS-00192_MultiCareIntl_3265.1r1.indd 3 6/21/12 11:02 AM
Elevating Table Assembly
Table Type .................................................Bi-directionalMotorized Height Range .............................40 to 57 in (102 to 145 cm)Table Surface Dimensions ..........................72 x 28 in (221 x 71 cm) ClosedMaximum Length .......................................106 in (269 cm) (17 in [43 cm] Leg Extensions Each End)Patient Weight Limit ................................... 300 lbs motorized weight limit
350 lbs standing weight limit
Undertable C-arm Assembly
Total Access ..............................................360° C-arm Rotation Angle 0° to 180° Continuously VariableC-arm Motion ............................................ Longitudinal: ±4 in (10.2 cm)
Transverse: ±4 in (10.2 cm)C-arm Motion ............................................7.75 in vertical travelWork Area Light ......................................... 2 Adjustable LED Lamps on C-arm
Under-table Aperture Lighting
Compression
Pre-compression .......................................MotorizedCompression .............................................Manual, Handwheel DrivenRelease .....................................................MotorizedControls ....................................................Keypad or by Function Footswitch
Stereotactic Guidance System
Type ........................................................ Cartesian Coordinate System with SmartWindowsAccuracy ...................................................±1.0 mmStereotactic Angle ......................................±15°Stage Movements ......................................X & Y Axis: Motorized; Z Axis: ManualDisplay Mode Options ................................ Needle Core Biopsy (NCB)
Fine Needle Aspiration (FNA) Wire Localization (WL)
X-ray Generator
Type.......................................................... Constant Potential, High Frequency, Inverter Type
Output Rating ............................................2.38kW (70mA at 34kV) MaximumInput Power ...............................................200/208/220/230/240 VAC, ±10%, 50/60 HzkV Range...................................................22 – 34kVmAs Range ................................................3-400mAsIdle Current ...............................................4 Amps MaximumMaximum Line Current ...............................35 Amps, 5 SecondsWeight ......................................................190 lbs (86 kg)Generator Control Unit ................................Handheld Controller
Handheld Controller
Components ..............................................LCD Screen, Function KeypadX-ray Exposure Switch Alerts ......................Exposure Technique, System Status
X-ray Tube
Anode Type ...............................................Molybdenum, RotatingAnode Speed .............................................3600 RPMTube Potential ........................................... 22kV – 34kV in 1kV Increments,
Constant PotentialTube Current ............................................. 80mA at 22kV – 28kV
70mA at 29kV – 34kVHeat Capacity ............................................300,000 HU (222 kJoules)Target-Tube Angle .....................................10°Focal Spot Size ..........................................0.25 mm Square – NominalPermanent Filtration ...................................30 μm MolybdenumPort ...........................................................Beryllium
System Weights
Table.........................................................940 lbs (426 kg)Generator....... ...........................................190 lbs (86 kg)DSM Cart (complete system) ......................258 lbs (117 kg)Accessory Cart (loaded)....... .......................165 lbs (74.8 kg)*
MultiCare® Platinum Table Specifications
109 cm(42.9 in.)
94 cm(37 in.)
65 cm(25.5 in.)
193 cm.(76 in.)
290 cm(114 in.)
132 cm(52 in.)
64 cm(25 in.)
38 cm(15 in.)
51 cm(20 in.)
91.4 cm(36 in.)
96.5 cm(38 in.)
157.5 cm(62 in.)
71.1 cm(28 in.)
GeneratorMultiCare Platinum Table DSM Cart Accessory Cart*
DS-00192_MultiCareIntl_3265.1r1.indd 4 6/21/12 11:02 AM
DSM® Specifications Digital Imaging Detector
System Features
Tissue Image Area .....................................5.5 x 5.5 cm at the Breast Platform (4.5 cm offset platform)Image Display Resolution............................512 or 1024 Pixel ResolutionImage Dynamic Range ...............................14 Bit Gray Scale (16,384 Gray Levels)Magnification Factor................................... 1.327 Measured from Center of
Compressed BreastEffective Pixel Size .....................................49.91 μm (H) x 49.91 μm (V)Pixel Resolution .........................................20.04 pixels/mm (1024 Mode)Spatial Resolution ......................................9 - 10 lp/mm (1024 Mode)Detective Quantum Efficiency .....................High
DSM Camera
Type.......................................................... CCD Sensor Coupled to High Efficiency LensIntensifying Screen.....................................High Efficiency Front PhosphorDigitzing Resolution. ...................................14 Bit DataDark Field Read Noise ................................25 Electrons (RMS)Saturation Signal ........................................ 113,000 Electrons (1024 Mode) 56,500 Electrons (512 Mode)Quantum Efficiency ....................................˜60% at 550nmOutput Sensitivity .......................................86.45 uV/electron (1024 Mode) 172.9 uV/electron (512 Mode)
CCD Sensor
Architecture ...............................................Full-frame CCDPixel Count ................................................1024 (H) x 1024 (V)Pixel Size ...................................................24 μm (H) x 24 μm (V)Optical Fill Factor .......................................100%Full Well Capacity ....................................... 1,400,000 Electrons (High Dynamic Range Output)Output Sensitivity .......................................1.53 uV/electron (High Dynamic Range Output)
Processing Station
Computer
Microprocessor ..........................................Intel Based Pentium CPU WorkstationOperating System ......................................Windows® XPArchive Media ............................................DVD+R/RW, CD-R/RW
Monitor
Type..........................................................LCD Flat PanelDisplay Area ..............................................18.1 in Diagonal (46 cm) MinimumViewing Angle ............................................170º (Typical)Resolution .................................................1280 x 1024Brightness .................................................700 cd/m2Pixel Pitch .................................................0.2850 x 0.2850 mmContrast Ratio ............................................550 to 1(Typical)Calibration .................................................DICOM
System Requirements
Input Power ...............................................100-120 VAC, 50-60 Hz, 5 Amps 220-240 VAC, 50-60 Hz, 2.5 AmpsAmbient OperatingTemperature Range .................................... 50º - 95º F (10º - 35º C)
Accessories
Standard Accessories
Compression Paddles
17 cm Stainless Steel Biopsy Paddle10 cm Stainless Steel Axillary Biopsy Paddle
Accessories
Standard 9 inch Table top ApertureStandard Access Table top Pad Arm-through Support Dual Function FootswitchRefuse TrayStool with BackrestQuality Assurance NeedleFNA Needle GuideNeedle Localization Guides14 G Needle GuidesNeedle Guide HolderAir PhantomDICOM PrintDSM Computer CartOperator’s Manual & Service Manual
Optional Accessories*
Expanded Kit for Maximum Comfort Table Includes:
PillowsAbdominal PillowWedge PillowHead Pillows (2)
Large Tabletop Aperture (10.5 in Diameter) Arm-through ApertureMaximum Access PadMaximum Comfort Pad Arm-through PadStorage Cart
Compression Paddles
Scout Biopsy PaddleT-shaped Ultrasound Biopsy PaddlePerforated Biopsy Paddle
Additional Table Accessories
Additional Stool with BackrestDICOM Store, Storage Commit, Query/Retrieve, Modality Worklist (PACS Dependant)Scout Film Aperture
**Additional charge applies
DS-00192_MultiCareIntl_3265.1r1.indd 5 6/21/12 11:02 AM
Hologic is defi ning the standard of care in women’s
health. Our technologies help doctors see better, know
sooner, reach further and touch more lives. At Hologic,
we turn passion into action, and action into change.
BREAST IMAGING SOLUTIONS | INTERVENTIONAL BREAST SOLUTIONS | BONE HEALTH
PRENATAL HEALTH | GYNECOLOGIC HEALTH | MOLECULAR DIAGNOSTICS
DS-00192 03/12 INTL ©2012 Hologic, Inc. All Rights Reserved. Printed in the United States. Specifi cations are subject to change without prior notice. Hologic, DSM and MultiCare are trademarks and/or registered trademarks of Hologic, Inc. and/or its subsidiaries in the United States and other countries.
North America/Latin America35 Crosby Drive Bedford, MA 01730-1401USA
Hologic BelgiumEverest (Cross Point)Leuvensesteenweg 250A1800 Vilvoorde Belgium
Hologic UK LimitedUnit 2, Link 10, Napier Way, Crawley, West Sussex, RH10 9RAUnited Kingdom
Hologic Asia Paci� c7th Floor, Biotech Centre 2No. 11 Science Park West Avenue Hong Kong Science Park Shatin, New Territories Hong Kong
Hologic AustraliaHologic (Australia) Pty LtdSuite 402, Level 42 Lyon Park RoadMacquarie Park NSW 2113Australia
www.hologic.com | [email protected]
Hologic ChinaHologic HealthcomeRoom 1606, Building A,Feng Lan Guo Ji Center32 Xi Zhi Men Bei Da JieHaidian District, Beijing, (100082)China