the environmental assessment and management (team) …the environmental assessment and management...

392
The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help determine compliance with current environmental regulations. The U.S. Air Force, U.S. Army, Defense Logistics Agency (DLA), and Corps of Engi- neers (Civil Works) have adopted environmental compliance programs that identify compliance problems before they are cited as violations by the U.S. Environmental Protection Agency. Since 1984, the U.S. Army Construction Engineering Re- search Laboratory, in cooperation with numerous Department of Defense (DOD) components, has developed environmental compliance assessment checklist manuals. The Environ- mental Assessment and Management (TEAM) Guide was developed for use by all DOD components. Currently there are five participating DOD components: the Air Force, Air National Guard, Army, Civil Works, and DLA. These agencies have agreed to share the development and maintenance of this Guide. The Guide combines Code of Federal Regulations and management practices into a series of checklists that show legal requirements and the specific operations or items to review. TEAM Guide is supplemented by DOD component- specific manuals detailing DOD component regulations and policies. The Illinois Supplement was developed to be used in conjunction with the TEAM Guide, using existing Illinois state environmental legislation and regulations as well as suggested management practices. CERL Special Report 97/114 June 1997 Revised June 2000 Approved for public release; distribution is unlimited.

Upload: others

Post on 19-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

The Environmental Assessment and Management (TEAM) Guide

Illinois Supplement Revised June 2000 Environmental assessments help determine compliance with current environmental regulations. The U.S. Air Force, U.S. Army, Defense Logistics Agency (DLA), and Corps of Engi-neers (Civil Works) have adopted environmental compliance programs that identify compliance problems before they are cited as violations by the U.S. Environmental Protection Agency.

Since 1984, the U.S. Army Construction Engineering Re-search Laboratory, in cooperation with numerous Department of Defense (DOD) components, has developed environmental compliance assessment checklist manuals. The Environ-mental Assessment and Management (TEAM) Guide was developed for use by all DOD components. Currently there are five participating DOD components: the Air Force, Air National Guard, Army, Civil Works, and DLA. These agencies have agreed to share the development and maintenance of this Guide.

The Guide combines Code of Federal Regulations and management practices into a series of checklists that show legal requirements and the specific operations or items to review. TEAM Guide is supplemented by DOD component- specific manuals detailing DOD component regulations and policies. The Illinois Supplement was developed to be used in conjunction with the TEAM Guide, using existing Illinois state environmental legislation and regulations as well as suggested management practices.

CERL Special Report 97/114 June 1997

Revised June 2000

Approved for public release; distribution is unlimited.

Page 2: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help
Page 3: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help
Page 4: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Introduction

i

FOREWORD This is USACERL Special Report 97/114. The report is based on the information available on Enflex Federal and State Regulations of May 2000. The research was performed for the Air National Guard under Military Interdepartmental Purchase Request (MIPR) number OMAF57/3400/357/A/9830147/PO, technical monitor Chuck Smith; the Army Environmental Center under MIPR 0C48R0006, technical monitor Matthew Andrews; the National Guard Bureau under MIPR 0CCER6EL11, technical monitor Phil Dao; the Air Force Center for Environmental Excellence under MIPR FQ7624-00-08010, technical monitor Scott Newquist; the U.S. Army Corps of Engineers under FAD3123-X-2402-JAN-980803369, technical monitor James Wolcott; the U.S. Army Reserve Center under MIPR 00CCWEL009, technical monitor Dave Jennings; and the U.S. Postal Service under MIPR number 102590-99-Z-093, technical monitor Paul Fennewald. The research was performed by the Environmental Processes Branch (CN-E), Installations Division (CN), of the U.S. Army Construction Engineering Research Laboratory (CERL). The CERL Principal Investigator was Carolyn O’Rourke. Dr. Ilker Adiguzel is Chief, CN-E, and Dr. John T. Bandy is Chief, CN. Dr. Alan Moore is Acting Director of CERL.

Page 5: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Introduction

ii

Page 6: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Introduction

iii

NOTICE This manual is intended as general guidance for personnel at Department of Defense (DOD) installations/CW facilities. It is not, nor is it intended to be, a complete treatise on environmental laws and regulations. Neither the U.S. Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information contained herein. For any specific questions about, or interpretations of, the legal references herein, consult appropriate legal counsel.

Page 7: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Introduction

iv

Page 8: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Introduction

v

ILLINOIS SUPPLEMENT The Illinois Supplement to the U.S. TEAM Guide contains the protocols necessary for determining compliance with Illinois environmental regulations. This manual is a supplement to the U.S. TEAM Guide; the manual does not replace it. The following Illinois agencies issue regulations and have responsibility in the areas indicated.

• Illinois Environmental Protection Agency - The Agency collects and disseminates information, acquires tech-nical data, and conducts experiments, ascertains the quantity and nature of discharges from any contaminant source and data on those sources, and operates and arranges for the operation of devices for the monitoring of environmental quality.

• Pollution Control Board - The Board determines, defines and implements the environmental control standards of

the State of Illinois and may adopt rules and regulations consistent with those standards. The Board has authority to act for the State in regard to the adoption of standards for submission to the United States under any federal law respecting environmental protection; to conduct hearings upon complaints charging violations of environmental regulations, upon petitions for variances, upon petitions for review of the Agency's denial of a permit, upon other petitions for review of final determinations which involve a subject which the Board is authorized to regulate, and such other hearings. In connection with any such hearing the Board may subpoena and compel the attendance of witnesses and the production of evidence reasonably necessary to resolution of the matter under consideration. The Board may prescribe reasonable fees for required permits, though such fees in the aggregate may not exceed the total cost to the Agency for its inspection and permit systems.

• Hazardous Waste Advisory Council - The Council reviews implementation of the procedures for the siting of

new pollution control facilities; reviews the state of the art of alternative treatment methods of hazardous wastes including recycling, incineration, physical, chemical and biological treatment, methods to reduce the amount of wastes produced and any other alternative waste management technologies and studies ways to promote the use of these techniques; and reviews all existing State and federal laws pertaining to the treatment, storage, transportation and disposal of hazardous wastes and their enforcement. The Council annually reports its findings in these areas to the Governor and the General Assembly, and suggests administrative and legislative changes which it believes are necessary to protect the public health, safety and welfare from hazardous wastes.

• Department of Agriculture Issues - the Department licenses and certifies individuals in the use of classified and

restricted use pesticides, and receives notification of pesticide incidents and misuse complaints.

• Emergency Management Agency (217/782-4694; 800/782-7860 all spills, 24 hours) - must be contacted immediately in the event of any unanticipated spill, whether under Title III or other state environmental laws.

• Department of Natural Resources (217/782-6302) - The Department is organized into the following divisions:

- Resource Conservation which oversees fisheries, wildlife, forestry, and natural heritage - Water Resources which issues permits for construction on lakes, streams, and waterways - Scientific Research and Analysis which conducts the water survey, natural history survey, and geological

survey - Energy and Environmental Assessment which issues permits for construction on state managed lands.

Page 9: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Introduction

vi

Page 10: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Introduction

vii

ACRONYMS ACGIH American Conference of Governmental Industrial Hygienists AQMA air quality management area ASTM American Society for Testing and Materials AWWA American Water Works Association BACT best available control technology BOD biochemical oxygen demand BTEX benzene, toluene, elthylbenzene, xylene CAR control area responsible party CAS Chemical Abstract Service CEM continuous emission monitoring CERCLA Comprehensive Environmental Response, Compensation, and Liability Act CFC chlorofluorocarbons CWA Clean Water Act dB decibel dBA decibels using A-weighting network dBC decibels using C-weighting network DEQ Department of Environmental Quality ESA Endangered Species Act FIFRA Federal Insecticide, Fungicide, and Rodenticide Act GVWR gross vehicle weight rating HEPA Filter high efficiency particulate air filter HWM hazardous waste management IARC International Agency for Research on Cancer ICRU International Commission on Radiological Units and Measure ments IUPAC International Union of Pure and Applied Chemistry LAER lowest achievable emission rate Ldn day-night airport noise level Leq equivalent noise level LPG Liquefied Petroleum Gas MC medium curing MCL maximum contaminant level MFL million fibers per liter MSDS material safety data sheet MSW municipal-type solid waste MSWLF municipal solid waste landfill MWC municipal waste combustor NBS National Bureau of Standards NEPA National Environmental Policy Act NFPA National Fire Protection Association NHPA National Historic Preservation Act NPDES National Pollutant Discharge Elimination System NTNCWS nontransient noncommunity water system OSHA Occupational Safety and Health Administration PAH polycyclic aromatic hydrocarbons PCB polychlorinated biphenyl PEL permissible exposure limit POTW publicly owned treatment works PUC Public Utility Commission of Oregon RACT reasonably available control technology

Page 11: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Introduction

viii

ACRONYMS

RC rapid curing RCRA Resource Conservation and Recovery Act RDF refuse-derived fuel REL recommended exposure level RGF recirculating gravel fFilter RVP Reid vapor pressure SAE Society of Automotive Engineers SARA Superfund Amendments and Reauthorization Act SC slow curing SDWA Safe Drinking Water Act SIC Standard Industrial Classification SMCL secondary maximum contaminant level SPCC spill prevention countermeasure and control SPL sound pressure level SWDA Solid Waste Disposal Act TLV threshold limit value TNTC too numerous to count TPH total petroleum hydrocarbons TRI toxic release inventory TSCA Toxic Substance Control Act TSD treatment, storage, and disposal TSDF treatment, storage, and disposal facility TSP total suspended particulate TSS total suspended solids TTHM total trihalomethane UL Underwriters Laboratory UFC Uniform Fire Code USEPA United States Environmental Protection Agency UST underground storage tank VOC volatile organic compound VOL volatile organic liquid WPCF Water Pollution Control Facilities

Page 12: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Introduction

ix

COMMONLY USED ABBREVIATIONS

bbl barrel mg milligram Btu British thermal unit mi mile C Celsius min minute cfs cubic feet per second MJ megajoule cm centimeter mL milliliter cm2 square centimeter mm millimeter dscf dry standard cubic foot mo month dscm dry standard cubic meter mrem millirem F Fahrenheit MW megawatt ft foot ng nanogram ft2 square feet NTU nephelometric turbidity unit ft3 cubic feet oz ounce g gram pCi picoCurie gal gallon ppm part per million gJ gigajoule ppmv part per million by volume gr grain ppmw part per million by weight h hour psi pound per square inch ha hectare psia pounds per square inch absolute hp horsepower psig pounds per square inch gauge in. inch qt quart J Joule s second kg kilogram scf standard cubic foot km kilometer scm standard cubic meter kPa kilopascals sdcf standard dry cubic foot L liter sdcm standard dry cubic meter lb pound TU turbidity unit m meter V volt m3 cubic meter yd yard MBtu million British thermal units yd2 square yard meq milligram equivalent yr year CO carbon monoxide NO2 nitrogen dioxide CO2 carbon dioxide NOx nitrogen oxides Hg mercury SO2 sulfur dioxide

Page 13: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Introduction

x

Page 14: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Introduction

xi

METRIC CONVERSION TABLE The following conversion table may be used throughout this manual to make approximate conversions between U.S. units and metric units.

1 in. = 2.54 cm or 25.4 mm 1 ft = 0.3048 m 1 ft2 = 0.093 m2

1 ft3 = 0.028 m3

1 psi = 6.895 kPa 1 lb = 0.454 kg 1 mi = 1.61 km 1 gal = 3.78 L °F = (°C + 17.78) x 1.8 °C = 0.55 (°F - 32) 1 yd = 0.9144 m 1 Btu = 4.184 kJ 1 acre = 4046.9 m2 1 acre = 0.405 hectare

Page 15: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Comment Form

Comments and questions regarding the Illinois Supplement can be addressed to:

Carolyn O’Rourke

e-mail [email protected] phone 217-398-5553 or 1-800-USACERL

fax 217-373-3430

Please include the following information with your comment: User Name: Affiliation (installation, command, etc.): email: Phone: FAX:

Page #

Checklist item #

Line #

Comments

Page 16: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

REPORT DOCUMENTATION PAGE Form Approved

OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding the burden estimate to any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations, 1215 Jefferson Davis Highway, Suite 12-4, Arlington, VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project (0704-0188), Washington, DC 20503. 1. AGENCY USE ONLY (Leave blank)

2. REPORT DATE

June 2000

3. REPORT TYPE AND DATES COVERED

Final

4. TITLE AND SUBTITLE

The Environmental Assessment and Management (TEAM) Guide Illinois Supplement, Revised

5. FUNDING NUMBERS

MIPR OMAF57/3400/357/A/9830147/PO (ANG) 0C48R0006 (AEC) 0CCER6EL11 (NGB) FQ7624-00-08010 (AFCEE) FAD3123-X-2402-JAN-980803369 (USACE)

6. AUTHOR(S)

Carolyn O’Rourke

00CCWEL009 (USARC) 102590-00-Z-093 (USPS)

7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES)

U.S. Army Construction Engineering Research Laboratory (CERL) P.O. Box 9005 Champaign, IL 61826-9005

8. PERFORMING ORGANIZATION REPORT NUMBER

SR 97/114, June 1997

9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES)

See report Foreword for a complete list of sponsors. 10. SPONSORING/MONITORING AGENCY REPORT NUMBER

11. SUPPLEMENTARY NOTES

Original document prepared by U.S. Army Construction Engineering Research Laboratory (CERL). Copies of this revised document are available from the National Technical Information Service, 5285 Port Royal Road, Springfield, VA, or can be downloaded from the HQ AFCEE or USACERL (Denix) Bulletin Boards. This guide updates and supercedes ADA330076. 12a. DISTRIBUTION/AVAILABILITY STATEMENT

Approved for public release; distribution is unlimited. 12b. DISTRIBUTION CODE

13. ABSTRACT (Maximum 200 words)

Environmental assessments help determine compliance with current environmental regulations. The U.S. Air Force, U.S. Army, Defense Logistics Agency (DLA), and Corps of Engineers (Civil Works) have adopted environmental compliance programs that identify compliance problems before they are cited as violations by the U.S. Environmental Protection Agency. Since 1984, the U.S. Army Construction Engineering Research Laboratory, in cooperation with numerous Department of Defense (DOD) components, has developed environmental compliance assessment checklist manuals. The Environmental Assessment and Management (TEAM) Guide was developed for use by all DOD components. Currently there are five participating DOD components: the Air Force, Air National Guard, Army, Civil Works, and DLA. These agencies have agreed to share the development and maintenance of this Guide. The Guide combines Code of Federal Regulations and management practices into a series of checklists that show legal requirements and the specific operations or items to review. TEAM Guide is supplemented by DOD component-specific manuals detailing DOD component regulations and policies. The Illinois Supplement was developed to be used in conjunction with the TEAM Guide, using existing Illinois state environmental legislation and regulations as well as suggested management practices. 14. SUBJECT TERMS

Environmental Compliance Assessment and Management Program The Environmental Assessment and Management (TEAM) Guide Environmental Compliance Laws and Regulations Environmental Compliance Checklists

15. NUMBER OF PAGES

16. PRICE CODE

17. SECURITY CLASSIFICATION OF REPORT

Unclassified

18. SECURITY CLASSIFICATION OF THIS PAGE

Unclassified

19. SECURITY CLASSIFICATION OF ABSTRACT

Unclassified

20. LIMITATION OF ABSTRACT

SAR

NSN 7540-01-280-5500 Standard Form 298 (Rev. 2-89)

Page 17: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-1 Air Emissions Management

SECTION 1

AIR EMISSIONS MANAGEMENT

Illinois Supplement, June 2000 This section covers the state requirements for Air Emissions Management and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Definitions

• Actual Heat Input - the quantity of heat produced by the combustion of fuel using the gross heating value of the

fuel (Title 35, Illinois Administrative Code, Section 211 (35 IAC 211)). • Afterburner - a device in which materials in gaseous effluents are combusted (35 IAC 211). • Agency - the Illinois Environmental Protection Agency (35 IAC 211). • Air Contaminant - any solid, liquid, or gaseous matter, any odor or any form of energy, that is capable of being

released into the atmosphere from an emission source (35 IAC 201). • Air Pollution - the presence in the atmosphere of one or more air contaminants in sufficient quantities and of

such characteristics and duration as to be injurious to human, plant, or animal life, to health, or to property, or to unreasonably interfere with the enjoyment of life or property (35 IAC 201).

• Air Pollution Control Equipment - any equipment or facility of a type intended to eliminate, prevent, reduce, or

control the emission of specified air contaminants to the atmosphere (35 IAC 201). • Ambient Air - that portion of the atmosphere external to buildings comprising emission sources (35 IAC 201). • Asphalt - the dark-brown to black cementitious material (solid, semisolid or liquid in consistency) of which the

main constituents are bitumens which occur naturally or as a residue of petroleum refining (35 IAC 211). • Asphalt Prime Coat - a low-viscosity liquid asphalt applied to an absorbent surface as the first of more than one

asphalt coat (35 IAC 211). • Batch HMIWI - an HMIWI that is designed in such a way that neither waste charging nor ash removal can occur

during combustion (35 IAC 229.102) [Added June 2000]. • Batch Loading - the process of loading a number of individual parts at the same time for degreasing (35 IAC

211). • Biologicals - preparations made from living organisms and their products, including vaccines, cultures etc.,

intended for use in diagnosing, immunizing, or treating humans or animals or in research pertaining thereto (35 IAC 229.102) [Added June 2000].

• Blood Products - any product derived from human blood, including but not limited to, blood plasma, platelets,

red or white blood corpuscles, and other derived licensed products, such as interferon, etc. (35 IAC 229.102)[Added June 2000].

Page 18: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-2 Air Emissions Management

• Body Fluids - liquid emanating or derived from humans and limited to: blood; dialysate; amniotic, cerebrospinal, synovial, pleural, peritoneal and pericardial fluids; semen and vaginal secretions (35 IAC 229.102) [Added June 2000].

• British Thermal Unit (Btu) - The quantity of heat required to raise one pound of water from 60 °F to 61 °F (35

IAC 211). • Bypass Stack - an alternative stack used for discharging combustion gases to the atmosphere primarily to avoid

severe damage to an air pollution control device or other equipment (35 IAC 229.102) [Added June 2000]. • Capture - the containment or recovery of emissions from a process for direction into a duct which may be

exhausted through a stack or vent to a control device. The overall abatement of emissions from a process with an add-on control device is a function both of the capture efficiency and of the control device (35 IAC 211).

• Capture Device - a hood, enclosed room floor sweep, or other means of collecting solvent or other pollutants

into a duct. The pollutant can then be directed to a pollution control device such as an afterburner or carbon adsorber. Sometimes the term is used loosely to include the control device (35 IAC 211).

• Capture Efficiency - the fraction of all volatile organic material (VOM) generated by a process that is directed to

an abatement or recovery device (35 IAC 211). • Capture System - all equipment (including, but not limited to, hoods, ducts, fans, ovens, dryers, etc.) used to

contain, collect, and transport an air pollutant to a control device (35 IAC 211). • Charge - the act of placing waste into an HMIWI for incineration (35 IAC 229.102) [Added June 2000]. • Chemotherapeutic Waste - waste material resulting from the production or use of antineoplastic agents used for

the purpose of stopping or reversing the growth of malignant cells (35 IAC 229.102) [Added June 2000]. • Chicago Area - the area comprised of Cook, DuPage, Kane, Lake, McHenry and Will Counties and Aux Sable

Township and Goose Lake Township in Grundy County and Oswego Township in Kendall County (35 IAC 218.100) [Added May 1999].

• Continuous Emission Monitoring System or CEMS - a monitoring system for continuously measuring and

recording the emissions of a pollutant from an affected facility (35 IAC 229.102) [Added June 2000]. • Co-fired Combustor - a unit combusting hospital waste or medical/infectious waste with other fuels or wastes

(e.g., coal, municipal solid waste) and subject to an enforceable requirement limiting the unit to combusting a fuel feed stream, of which 10 percent or less of the weight is comprised, in aggregate, of hospital waste and medical/infectious waste as measured on a calendar quarter basis. For purposes of this definition, pathological waste, chemotherapeutic waste, and low-level radioactive waste are considered other wastes when calculating the percentage of hospital waste and medical/infectious waste combusted (35 IAC 229.102) [Added June 2000].

• Co-fired Combustor - a unit combusting hospital waste and/or medical/infectious waste with other fuels or

wastes (e.g., coal, municipal solid waste) and subject to an enforceable requirement limiting the unit to combusting a fuel feed stream, 10 percent or less of the weight of which is comprised, in aggregate, of hospital waste and medical/infectious waste as measured on a calendar quarter basis. For purposes of this definition, pathological waste, chemotherapeutic waste, and low-level radioactive waste are considered other wastes when calculating the percentage of hospital waste and medical/infectious waste combusted (40 CFR 60.51c).

• Cold Cleaning - the process of cleaning and removing soils from surfaces by spraying, brushing, flushing, or

immersion while maintaining the organic solvent below its boiling point. Wipe cleaning is not included in this definition (35 IAC 211).

Page 19: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-3 Air Emissions Management

• Commence - the act of entering into a binding agreement or contractual obligation to undertake and complete, within a reasonable time, a continuous program of construction or modifications (35 IAC 201).

• Condensate - hydrocarbon liquid separated from its associated gasses which condenses due to changes in the

temperature or pressure and remains liquid at standard conditions (35 IAC 211). • Construction - commencement of on-site fabrication, erection, or installation of an emission source or of air

pollution control equipment (35 IAC 201). • Continuous HMIWI - an HMIWI that designed to allow waste charging and ash removal during combustion (35

IAC 229.102) [Added June 2000]. • Control Device - equipment (such as an afterburner or adsorber) used to remove or prevent the emission of air

pollutants form a contaminated exhaust stream (35 IAC 211). • Control Device Efficiency - the ratio of the pollution prevented by a control device and the pollution introduced

to the control device, expressed as a percentage (35 IAC 211). • Conventional Air Spray - a spray coating method in which the coating is atomized by mixing it with compressed

air at an air pressure greater than 10 pounds per square inch (gauge) at the point of atomization. Airless, air assisted airless and electrostatic spray technologies are not conventional air spray (35 IAC 211) [Added May 1998].

• Conveyorized Degreasing - the continuous process of cleaning and removing soils from surfaces utilizing either

cold or vaporized solvents (35 IAC 211). • Cutback Asphalt - any asphalt which has been liquefied by blending with petroleum solvents other than residual

fuel oil and has not been emulsified with water (35 IAC 211). • Degreaser - any equipment or system used in solvent cleaning (35 IAC 211). • Dioxins/Furans - the total emissions of any tetra- through octa-chlorinated dibenzo-para-dioxins and

dibenzofurans, as measured by EPA Reference Method 23, incorporated by reference in Section 229.104(d) of this Subpart (35 IAC 229.102) [Added June 2000].

• Domicile Waste - any refuse generated on single-family domiciliary property as a result of domiciliary activities. The term excludes landscape waste, garbage, and trade waste (35 IAC 211).

• Dry Cleaning Facility - a facility engaged in the cleaning of fabrics using an essentially nonaqueous solvent by

means of one or more solvent washes, extraction of excess solvent by spinning and drying by tumbling in an airstream. The facility includes, but is not limited to, washers, dryers, filter and purification systems, waste disposal systems, holding tanks, pumps and attendant piping and valves (35 IAC 211).

• Dry Scrubber - an add-on air pollution control system that injects dry alkaline sorbent (dry injection) or sprays

an alkaline sorbent (spray dryer) to react with and neutralize acid gases in an HMIWI exhaust stream, forming a dry powder material (35 IAC 229.102) [Added June 2000].

• Effluent Water Separator - any tank, box, sump, or other apparatus in which any organic material floating on or

entrained or contained in water entering such tank, box, sump, or other apparatus is physically separated and removed from such water prior to outfall, drainage, or recovery of such water (35 IAC 211).

• Electronic Component - for the purposes of 35 Ill. Adm. Code 218.182(f) and 219.182(f), all portions of an

electronic assembly, including, but not limited to, circuit board assemblies, printed wire assemblies, printed

Page 20: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-4 Air Emissions Management

circuit boards, soldered joints, ground wires, bus bars, and associated electronic component manufacturing equipment such as screens and filters (35 IAC 211) [Added May 1998].

• Emission Rate - total quantity of any air contaminant discharge into the atmosphere in any one hour period (35

IAC 211). • Emission Source - any equipment or facility of a type capable of emitting specified air contaminants to the

atmosphere (35 IAC 201). • Existing Air Pollution Control Equipment - any air pollution control equipment, the construction or modification

of which has commenced prior to 14 April 1972 (35 IAC 201). • Existing Emission Source - any emission source, the construction or modification of which has commenced prior

to 14 April 1972 (35 IAC 201). • Fabric Filter - an add-on air pollution control system that removes PM and nonvaporous metals emissions by

passing flue gas through filter bags (35 IAC 229.102) [Added June 2000]. • Facilities Manager - the individual in charge of purchasing, maintaining, and Operating an HMIWI, or the

owner's or operator's representative responsible for the management of an HMIWI. Alternative titles may include director of facilities or vice president of support services (35 IAC 229.102) [Added June 2000].

• Flexographic Printing - the application of words, designs, and pictures to a substrate by means of a roll printing

technique in which the pattern to be applied is raised above the printing roll and the image carrier is made of elastomeric materials (35 IAC 211).

• Freeboard Height - for open top vapor degreasers, the distance from the top of the vapor zone to the top of the

degreaser tank. For cold cleaning degreasers, the distance from the solvent to the top of the degreaser tank (35 IAC 211).

• Fuel Combustion Emission Source - any furnace, boiler, or similar equipment used for the primary purpose of

producing heat or power by indirect heat transfer (35 IAC 211). • Fugitive Emissions - those emissions which could not reasonably pass through a stack, chimney, vent, or other

functionally equivalent opening (35 IAC 211). • Garbage - refuse resulting from the handling, processing, preparation, cooking, and consumption of food or

food products (35 IAC 237). • Heavy Duty Vehicle - a vehicle with 8000 lb or greater manufacturer’s maximum gross vehicle weight rating

(GVWR) (35 IAC 240). • High Air Phase - the stage of the batch Operating cycle when the primary chamber reaches and maintains

maximum operating temperatures (35 IAC 229.102) [Added June 2000].

• Hood - a partial enclosure or canopy for capturing and exhausting, by means of a draft, the organic vapors or other fumes rising from a coating process or other source (35 IAC 211).

• Hospital - any facility that has an organized medical staff, maintaining at least 6 inpatient beds and where the primary function of the facility is to provide diagnostic and therapeutic patient services and continuous nursing care primarily to human inpatients who are not related and who stay on average in excess of 24 hours per admission. This definition does not include facilities maintained for the sole purpose of providing nursing or convalescent care to human patients who generally are not acutely ill but who require continuing medical supervision (35 IAC 229.102) [Added June 2000].

Page 21: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-5 Air Emissions Management

• Hospital/Medical/Infectious Waste Incinerator or HMIWI or HMIWI Unit - any device that combusts any

amount of hospital waste and/or medical/infectious waste (35 IAC 229.102)[Added June 2000].

• Hospital/Medical/Infectious Waste Incinerator or HMIWI - any device that combusts any amount of hospital waste or medical/infectious waste (35 IAC 229.102) [Added June 2000].

• Hospital Waste - discards generated at a hospital, except unused items returned to the manufacturer. The definition of hospital waste does not include human corpses, remains, or anatomical parts that are intended for interment or cremation (35 IAC 229.102) [Added June 2000].

• HMIWI Operator - any person who operates, controls, or supervises the day-to-day operation of an HMIWI (35 IAC 229.102) [Added June 2000].

• Incinerator - combustion apparatus in which refuse is burned (35 IAC 211). • Indirect Heat Transfer - transfer of heat in such a way that the source of heat does not come into direct contact

with process materials (35 IAC 211). • Infectious Agent - any organism that is capable of being communicated by invasion and multiplication in body

tissues and is also capable of causing disease or adverse health impacts in humans (35 IAC 229.102) [Added June 2000].

• Ink - a coating used in printing, impressing, or transferring an image onto a substrate (35 IAC 211). • Intermittent HMIWI - an HMIWI that is designed to allow waste charging, but not ash removal, during

combustion (35 IAC 229.102) [Added June 2000]. • Landscape Waste - any vegetable or plant refuse, except garbage and agricultural waste. The term includes trees,

tree trimmings, branches, stumps, brush, weeds, leaves, grass, shrubbery, and yard trimmings (35 IAC 237). • Large HMIWI -I (35 IAC 229.102) [Added June 2000]:

1. An HMIWI whose maximum design waste burning capacity is more than 500 lbs per hour; or 2. A continuous or intermittent HMIWI whose maximum charge rate is more than 500 lbs per hour; or 3. A batch HMIWI whose maximum charge rate is more than 4,000 lbs per day.

• Light Duty Truck - a motor vehicle rated at 8000 lb gross vehicle weight or less, which is designed for carrying

more than 10 persons or designed for the transportation of property, freight or cargo, or is a derivative of such a vehicle (35 IAC 240).

• Light Duty Vehicle - a passenger car designed to carry not more than 10 persons (35 IAC 240). • Low-Level Radioactive Waste - waste that contains radioactive nuclides emitting primarily beta or gamma

radiation, or both, in concentrations or quantities that exceed applicable Federal or State standards for unrestricted release. Low-level radioactive waste is not high-level radioactive waste, spent nuclear fuel, or by-product material as defined by the Atomic Energy Act of 1954 (42 USC 2014(e)(2)) (35 IAC 229.102) [Added June 2000].

• Major Metropolitan Area (MMA) - any county or group of counties which is defined by the following (35 IAC

211):

MMA COUNTIES INCLUDED IN MMA

Champaign-Urbana Chicago

Champaign Cook, Lake, Will, DuPage, McHenry, Kane,

Page 22: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-6 Air Emissions Management

Decatur Peoria Rockford Rock Island - Moline Springfield St. Louis (Illinois) Bloomington - Normal

Grundy, Kendall, Kankakee Macon Peoria, Tazewell Winnebago Rock Island Sangamon St. Claire, Madison McLean

• Malfunction - any sudden, infrequent, and not reasonably preventable failure of air pollution control equipment,

process equipment, or of a process to operate in a normal or usual manner. Failures that are caused, in part, by poor maintenance or careless operation are not malfunctions (35 IAC 229.102) [Added June 2000].

• Maximum Charge Rate - (35 IAC 229.102) [Added June 2000]: 1. For continuous and intermittent HMIWI, 110 percent of the lowest 3-hour average charge rate measured

during the most recent performance test demonstrating compliance with all applicable emission limits specified in Subpart E of this Part.

2. For batch HMIWI, 110 percent of the lowest daily charge rate measured during the most recent performance test demonstrating compliance with all applicable emission limits specified in Subpart E of this Part.

• Maximum Design Waste Burning Capacity - (35 IAC 229.102) [Added June 2000]:

1. For intermittent and continuous HMIWI: C =P(V) x 15,000 / 8,500

2. Where: C = HMIWI capacity, lb/hr P(V) = primary chamber volume, ft3 15,000 = primary chamber heat release rate factor, Btu/ft3/hr 8,500 = standard waste heating value, Btu/lb;

3. For batch HMIWI: C = P(V) x 4.5 / 8

4. where: C = HMIWI capacity, lb/hr P(V) = primary chamber volume, ft3 4.5 = waste density factor, lb/ft3 8 = typical hours of operation of a batch HMIWI, hours.

• Maximum Fabric Filter Inlet Temperature - 110 percent of the lowest 3-hour average temperature at the inlet to

the fabric filter (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the applicable dioxin/furan emission limit specified in Subpart E of this Part (35 IAC 229.102) [Added June 2000].

• Maximum Flue Gas Temperature - 110 percent of the lowest 3-hour average temperature at the Outlet from the wet scrubber (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the applicable Hg emission limit specified in Subpart E of this Part (35 IAC 229.102) [Added June 2000].

• Medical/Infectious - any waste generated in the diagnosis, treatment, or immunization of human beings or animals, in research pertaining thereto, or in the production or testing of biologicals. The definition of medical/infectious waste does not include hazardous waste identified or listed under the regulations in 40 CFR 261; household waste, as defined in 40 CFR 261.4(b)(1); and domestic sewage materials identified in 40 CFR 261.4(a)(1). For the purposes of this Part, medical/infectious waste includes Waste (35 IAC 229.102) [Added June 2000]:

Page 23: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-7 Air Emissions Management

1. Cultures and stocks of infectious agents and associated biologicals, including: vaccines and cultures intended for use in diagnosing, immunizing, or treating humans or animals; cultures from medical and pathological laboratories; cultures and stocks of infectious agents from research and industrial laboratories; wastes from the production of biologicals; and discarded live and attenuated vaccines;

2. Human pathological waste, including tissues, organs, and body parts and body fluids that are removed during surgery or autopsy, or other medical procedures, and specimens of body fluids and their containers;

3. Human blood, any products derived from human blood, or anything that has been in contact with human blood in any form;

4. Intravenous bags and associated tubing; 5. Sharps that have been used in animal or human patient care or treatment or in medical, research, or

industrial laboratories, including hypodermic needles, syringes (with or without the attached needle), pasteur pipettes, scalpel blades, blood vials, and needles with attached tubing;

6. Culture dishes, regardless of the presence of infectious agents, and culture dishes and devices used to transfer, inoculate, and mix cultures;

7. Any type of broken or unbroken glassware that has been in contact with infectious agents; 8. Animal waste, including contaminated animal carcasses, body parts, bedding of animals that were known

to have been exposed to infectious agents during research (including research in veterinary hospitals), production of biologicals or testing of pharmaceuticals;

9. Isolation wastes, including biological waste and discarded materials contaminated with blood, excretions, exudates, or secretions from humans who are isolated to protect others from highly communicable diseases, or isolated animals known to be infected with highly communicable diseases; and

10. Unused sharps, including the following unused, discarded sharps: hypodermic needles, suture needles, syringes, and scalpel blades.

• Medium HMIWI - (35 IAC 229.102) [Added June 2000]:

1. An HMIWI whose maximum design waste burning capacity is more than 200 lbs per hour but less than or equal to 500 lbs per hour; or

2. A continuous or intermittent HMIWI whose maximum charge rate, as set by permit, is more than 200 lbs per hour but less than or equal to 500 lbs per hour; or

3. A batch HMIWI whose maximum charge rate, as set by permit, is more than 1,600 lbs per day but less than or equal to 4,000 lbs per day.

• Metro East Area - the area comprised of Madison, Monroe, and St. Clair Counties (35 IAC 219.100) [Added

May 1999].

• Minimum Dioxin/furan Sorbent Flow - 90 percent of the highest 3-hour average dioxin/furan sorbent flow rate (taken, at a minimum, once every hour) measured during the most recent performance test demonstrating compliance with the applicable dioxin/furan emission limit specified in Subpart E of this Part Rate (35 IAC 229.102) [Added June 2000].

• Minimum Hg Sorbent Flow Rate - 90 percent of the highest 3-hour average Hg sorbent flow rate (taken, at a minimum, once every hour) measured during the most recent performance test demonstrating compliance with the applicable Hg emission limit specified in Subpart E of this Part (35 IAC 229.102) [Added June 2000].

• Minimum HCl Sorbent Flow Rate (35 IAC 229.102) [Added June 2000] - 90 percent of the highest 3-hour

average HCl sorbent flow rate (taken, at a minimum, once every hour) measured during the most recent performance test demonstrating compliance with the applicable HCl emission limit specified in Subpart E of this Part.

• Minimum Horsepower or Minimum Amperage - 90 percent of the highest 3-hour average horsepower or amperage to the wet scrubber (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the applicable emission limits specified in Subpart E of this Part (35 IAC 229.102) [Added June 2000].

Page 24: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-8 Air Emissions Management

• Minimum Pressure Drop Across the Wet Scrubber - 90 percent of the highest 3-hour average pressure drop across the wet scrubber PM control device (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the applicable PM emission limit specified in this Subpart E of this Part (35 IAC 229.102) [Added June 2000].

• Minimum Scrubber Liquor Flow Rate - 90 percent of the highest 3-hour average liquor flow rate at the inlet to the wet scrubber (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the applicable emission limits specified in Subpart E of this Part (35 IAC 229.102) [Added June 2000].

• Minimum Scrubber Liquor pH - 90 percent of the highest 3-hour average liquor pH at the inlet to the wet scrubber (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the applicable HCl emission limit specified in Subpart E of this Part (35 IAC 229.102) [Added June 2000].

• Minimum Secondary Chamber Temperature - 90 percent of the highest 3-hour average secondary chamber temperature (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the applicable PM, CO, and dioxin/furan emission limits specified in Subpart E of this Part (35 IAC 229.102) [Added June 2000].

• Model Year - the year of manufacture of a motor vehicle based upon the annual production period as designated by the manufacturer and indicated on the title and registration of the vehicle. If the manufacturer does not designate a production period for the vehicle, then model year means the calendar year of manufacture (35 IAC 240).

• Modification or Modified HMIWI - any change to an HMIWI unit after the effective date of these standards such that (40 CFR 60.51c):

1. The cumulative costs of the modifications, over the life of the unit, exceed 50 per centum of the original cost of the construction and installation of the unit (not including the cost of any land purchased in connection with such construction or installation) updated to current costs, or

2. The change involves a physical change in or change in the method of operation of the unit which increases the amount of any air pollutant emitted by the unit for which standards have been established under section 129 or section 111.

• Modification - any physical change in, or change in the method of operations, of an emission source or of air

pollution control equipment which increases the amount of any specified air contaminant emitted by such source or equipment or which results in the emission of any specified air contaminant not previously emitted (35 IAC 201).

• New Air Pollution Control Equipment - any air pollution control equipment, the construction or modification of

which is commenced on or after 14 April 1972 (35 IAC 201). • New Emission Source - any emission source, the construction or modification of which is commenced on or after

14 April 1972 (35 IAC 201). • Opacity - a condition which renders material partially or wholly impervious to transmission of light and causes

obstruction of an observer’s view. For the purposes of these regulations, the following equivalence between opacity and Ringelmann shall be employed:

Opacity Percent Ringelmann 10 0.5 20 1.0 30 1.5 40 2.0

Page 25: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-9 Air Emissions Management

60 3.0 80 4.0 100 5.0 • Open Burning - the combustion of any matter in such a way that the products of the combustion are emitted to

the open air without originating in or passing through equipment (35 IAC 237). • Open Top Vapor Degreasing - the batch process of cleaning and removing soils from surfaces by condensing

hot solvent vapor on colder metal parts (35 IAC 211). • Operating Day (35 IAC 229.102) [Added June 2000]- a 24-hour period between 12:00 midnight and the

following midnight during which any amount of hospital waste or medical/infectious waste is combusted at any time in an HMIWI.

• Operation - any period during which waste is combusted in an HMIWI, excluding periods of startup or shutdown (35 IAC 229.102) [Added June 2000].

• Organic Compound - any compound of carbon, excluding carbon monoxide, carbon dioxide, carbonic acid,

metal carbides or carbonates, and ammonium carbonate (35 IAC 211). • Organic Material - any chemical compound of carbon including diluents and thinners which are liquids at

standard conditions and which are used as dissolvers, viscosity reducers, or cleaning agents, but excluding methane, carbon monoxide, carbon dioxide, carbonic acid, metallic carbonic acid, metallic carbide, metallic carbonates, and ammonium carbonate (35 IAC 211).

• Organic Vapor - the gaseous phase of an organic material or a mixture of organic materials present in the

atmosphere (35 IAC 211). • Packaging Rotogravure Printing - rotogravure printing upon paper, paper board, metal foil, plastic film and

other substrates, which are, in subsequent operations, formed into packaging products or labels for articles to be sold (35 IAC 211).

• Particulate Matter - any solid or liquid material, other than water, which exists in finely divided form (35 IAC

211). • Parts Per Million (Volume) (ppmv) - a volume/volume ratio which expresses the volumetric concentration of

gaseous air contaminant in a million unit volume of gas (35 IAC 211). • Pathological Waste - waste material consisting of only human or animal remains, anatomical parts, tissue, and

the bags or containers used to collect and transport the waste material and associated animal bedding, if applicable (35 IAC 229.102) [Added June 2000].

• Primary Chamber - the chamber in an HMIWI that receives waste material, in which the waste is ignited, and from which ash is removed (35 IAC 229.102) [Added June 2000].

• Printing - the application of words, designs, and pictures to a substrate using ink (35 IAC 211). • Printing Line - an operation consisting of a series of one or more roll printers and any associated roll coaters,

drying areas, and ovens wherein one or more coatings are applied, dried, and/or cured (35 IAC 211). • Publication Rotogravure Printing - rotogravure printing upon paper which is subsequently formed into books,

magazines, catalogues, brochures, directories, newspaper supplements, or other types of non-packaging printed material (35 IAC 211).

Page 26: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-10 Air Emissions Management

• Pyrolysis - the endothermic gasification of hospital waste and/or medical/infectious waste using external energy (35 IAC 229.102)[Added June 2000].

• Refuse - any discarded matter, or any matter which is to be reduced in volume, or otherwise changed in chemical

or physical properties, in order to facilitate its discard, removal, or disposal (35 IAC 237). • Ringelmann Chart - the chart published and described in the Bureau of Mines, U.S. Department of Interior

Information Circular 8333 (Revision of IC7718) May 1, 1967, or any adaptation thereof which has been approved by the Agency (35 IAC 211).

• Roll Printing - the application of words, designs and pictures to a substrate usually by means of a series of hard

rubber or metal rolls each with only partial coverage (35 IAC 211). • Rotogravure Printing - the application of words, designs and pictures to a substrate by means of a roll printing

technique in which the pattern to be applied is recessed relative to the non-image area (35 IAC 211). • Rural HMIWI (35 IAC 229.102) - any HMIWI identified in Section 229.110(a) of this Part, that is located more

than 50 miles from the boundary of the nearest Standard Metropolitan Statistical Area, as defined in OMB Bulletin No. 93-17, incorporated by reference at Section 229.104(b) of this Part, meets the criteria specified in the definition of small HMIWI and burns less than 2,000 lbs per week of hospital waste and medical/infectious waste (except the 2,000 lbs per week limitation does not apply during performance testing) [Added June 2000].

• Safety Relief Valve - a valve which is normally closed and which is designed to open in order to relieve

excessive pressures within a vessel or pipe (35 IAC 211). • Secondary Chamber - that component of an HMIWI that receives combustion gases from the primary chamber

and in which the combustion process is completed (35 IAC 229.102) [Added June 2000].

• Secondary Emissions - the emissions which would occur as a result of the construction or operation of a major stationary source or major modification, but do not come from the major stationary source or major modification itself (35 IAC 211).

• Shutdown - the period of time after all waste has been combusted in the primary chamber (35 IAC 229.102)

[Added June 2000]. • Small HMIWI (35 IAC 229.102) [Added June 2000] :

1. An HMIWI whose maximum design waste burning capacity is less than or equal to 200 lbs per hour; or 2. A continuous or intermittent HMIWI whose maximum charge rate, as set by permit, is less than or equal to

200 lbs per hour; or 3. A batch HMIWI whose maximum charge rate, as set by permit, is less than or equal to 1,600 lbs. per day.

• Smoke - small gas-borne particles resulting from incomplete combustion, consisting predominantly but not

exclusively of carbon, ash, and other combustible material, that form a visible plume in the air (35 IAC 211). • Solvent - a liquid substance that is used to dissolve or dilute another substance (35 IAC 211). • Solvent Cleaning - the process of cleaning soils from surfaces by cold cleaning, open top vapor degreasing or

conveyorized degreasing (35 IAC 211). • Splash Loading - a method of loading a tank, railroad tank car, tank truck or trailer by use of other than a

submerged loading pipe (35 IAC 211). • Standard Conditions - a temperature of 20 οC and a pressure of 101.3 kPa (35 IAC 229.102)[Added June 2000].

Page 27: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-11 Air Emissions Management

• Standard Cubic Foot (scf) - the volume of one cubic foot of gas at standard conditions (35 IAC 211). • Startup - the setting in operation of an emission source for any purpose (35 IAC 211). • Startup the period of time between the activation of an HMIWI and the first charge of waste to the unit. For

batch HMIWI, startup - the period of time between activation of an HMIWI and ignition of the waste (35 IAC 229.102) [Added June 2000].

• Standard Conditions - a temperature of 70 °F and a pressure of 14.7 psia (35 IAC 211). • Stationary Emission Source - an emission source which is not self-propelled (35 IAC 211). • Stationary Source - any building, structure, or facility which emits or may emit any air pollutant subject to

regulation under the Act or this Chapter or by USEPA under the Clean Air Act (42 U.S.C. 7401 et seq.) (35 IAC 211).

• Strippable Spray Booth Coating - a coating that is applied to a spray booth wall to provide a protective film to

receive overspray during finishing operations and that is subsequently peeled off and disposed of (35 IAC 211) [Added May 1998].

• Substrate - the surface onto which a coating is applied or unto which a coating is impregnated (35 IAC 211). • Volatile Organic Compound (VOC) - see Volatile Organic Material. • Volatile Organic Material (VOM) or Volatile Organic Compound (VOC) - any compound of carbon, excluding

carbon monoxide, carbon monoxide, carbon dioxide, carbonic acid, metallic carbides or carbonates, and ammonium carbonate, which participates in atmospheric photochemical reactions. This includes any such organic compound other than the following, which have been determined to have negligible photochemical reactivity (35 IAC 211) [Revised May 1999]:

1. methane 2. ethane 3. methylene chloride (dichloromethane) 4. 1,1,1-trichloroethane (methyl chloroform) 5. 1,1,2-trichloro-1,2,2-trifluoroethane (CFC-113) 6. trichlorofluoromethane (CFC-11) 7. dichlorodifluoromethane (CFC-12) 8. chlorodifluoromethane (CFC-22) 9. trifluoromethane (HFC-23) 10. difluoromethane (HFC-32) 11. ethylfluoride (HFC-161) 12. 1,2-dichloro-1,1,2,2-tetrafluoroethane (CFC-114) 13. chloropentafluoroethane (CFC-115) 14. 1,1,1-trifluoro-2,2-dichloroethane (HCFC-123) 15. 1,1,1,2-tetrafluoroethane (HFC-134a) 16. 1,1,1,2,3,3-hexafluoropropane (HFC-236ea) 17. 1,1,1,3,3,3-hexafluoropropane (HFC-236fa) 18. 1,1,2,2,3-pentafluoropropane (HFC-245ca) 19. 1,1,2,3,3-pentafluoropropane (HFC-245ea) 20. 1,1,1,2,3-pentafluoropropane (HFC-245eb) 21. 1,1,1,3,3-pentafluoropropane (HFC-245fa) 22. 1,1,1,3,3-pentafluorobutane (HFC-365mfc) 23. chlorofluoromethane (HCFC-31) 24. 1,2-dichloro-1,1,2-trifluoroethane (HCFC-123a) 25. 1,1-dichloro-1-fluoroethane (HCFC-141b)

Page 28: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-12 Air Emissions Management

26. 1,1-dichloro-1-fluoroethane (HCFC-141b) 27. 1-chloro-1,1-difluoroethane (HCFC-142b) 28. 2-chloro-1,1,1,2-tetrafluoroethane (HCFC-124) 29. pentafluoroethane (HFC-125) 30. 1-chloro-1-fluoroethane (HCFC-151a) 31. 3,3-dichloro-1,1,1,2,2-pentafluoropropane (HCFC-225ca) 32. 1,3-dichloro-1,1,2,2,3-pentafluoropropane (HCFC-225cb) 33. 1,1,1,2,3,4,4,5,5,5-decafluoropentane (HFC-43-10mee) 34. 1,1,2,2-tetrafluoroethane (HFC-134) 35. 1,1,1-trifluoroethane (HFC-143a) 36. 1,1-difluoroethane (HFC-152a) 37. perfluorocarbon parachlorobenzotrifluoride (PCBTF) 38. 1,1,1,2,2,3,3,4,4-nonafluoro-4-methoxybutane (C(4)F(9)OCH(3)) 39. 1-ethoxy-1,1,2,2,3,3,4,4,4-nonafluorobutane (C(4)F(9)OC(2)H(5)) 40. 2-(difluoromethoxymethyl)-1,1,1,2,3,3,3-heptafluoropropane 41. ((CF(3))(2)CFCF(2)OCH(3)) 42. 2-(ethoxydifluoromethyl)-1,1,1,2,3,3,3-heptafluoropropane 43. ((CF(3))(2)CFCF(2)OC(2)H(5)) 44. perchloroethylene (tetrachloroethylene) 45. cyclic, branched, or linear completely-methylated siloxanes 46. acetone (2-propanone or dimethylketone) 47. methyl acetate 48. perfluorocarbon compounds which fall into these classes:

a. cyclic, branched, or linear, completely fluorinated alkanes b. cyclic, branched, or linear, completely fluorinated ethers with no unsaturations c. cyclic, branched, or linear, completely fluorinated tertiary amines with no unsaturations and d. sulfur containing perfluorocarbons with no unsaturations and with sulfur bonds only to carbon and

fluorine. • Volatile Organic Liquid (VOL) - any substance which is liquid at storage conditions and which contains volatile

organic compounds (35 IAC 211). • Volatile Petroleum Liquid - any petroleum liquid with a true vapor pressure greater than 1.5 psia (78 mm Hg) at

standard conditions (35 IAC 211). • Washoff Operations - those operations in which organic solvent is used to remove coating from a substrate (35

IAC 211) [Added May 1998]. • Wastewater (Oil/Water) Separator - any device or piece of equipment which utilizes the difference in density

between oil and water to remove oil and associated chemicals of water, or any device, such as a flocculation tank or a clarifier, which removes petroleum derived compounds from waste water (35 IAC 211).

• Wet Scrubber - an add-on air pollution control device that utilizes either an alkaline or some other type of

scrubbing liquor to collect pollutants and/or neutralize acid gases (Source: Adopted at 23 Ill. Reg. 6477, effective May 15, 1999) (35 IAC 229.102) [Added June 2000].

Page 29: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-13 Air Emissions Management

AIR EMISSIONS MANAGEMENT GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: Missing Checklist Items AE.2.1.IL. Permits/Notifications/Exemptions AE.6.1.IL. Management/Administrative AE.7.1.IL. through AE.7.3.IL. Operations AE.8.1.IL. and AE.8.2.IL. Emissions Limits AE.9.1.IL. through AE.9.6.IL. Fuel-Burning Equipment AE.15.1.IL. through AE.15.12.IL. Miscellaneous Incinerators AE.25.1.IL. and AE.25.2.IL. Medical Waste Incinerators

General Existing HMIWIs AE.30.1.IL through AE.30.9.IL.

Monitoring Existing HMIWIs AE.32.1.IL through AE.32.6.IL.

Reporting/Recordkeeping Requirements Existing HMIWIs AE.34.1.IL through AE.34.9.IL.

Gasoline and Fuels AE.55.1.IL. and AE.55.2.IL. Printing Presses and Graphic Arts AE.60.1.IL. Fugitive Emissions AE.65.1.IL. and AE.65.2.IL. Dry Cleaning Operations

Petroleum Solvent AE.70.1.IL. through AE.70.4.IL. Perchloroethylene AE.75.1.IL. and AE.75.2.IL.

Acid Production Units AE.80.1.IL. and AE.80.2.IL. Coating Operations AE.100.1.IL.

Motor Vehicle Refinishing AE.100.2.IL. through AE.100.8.IL. Degreasing Operations

Cold Cleaning AE.116.1.IL. and AE.116.2.IL. Cold Cleaners in the Chicago Area AE.116.3.IL. Cold Cleaners in the Metro East Area AE.116.4.IL. Vapor Cleaning AE.117.1.IL. and AE.117.2.IL. Conveyorized Degreasers AE.117.3.IL. and AE.117.4.IL.

Open Burning AE.130.1.IL. Vehicle Emissions AE.135.1.IL. Asphalt Paving Materials/Operations AE.145.1.IL. County/City-Specific Requirements

Sources Located in Chicago, St. Louis (Illinois), or Peoria MMAs

AE.160.1.IL.

Small Sources Located Outside Metropolitan Areas AE.160.2.IL. Large Sources Located In Large Metropolitan Areas AE.160.3.IL.

Page 30: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-14 Air Emissions Management

GUIDANCE FOR APPENDIX USERS

REFER TO APPENDIX NUMBERS: REFER TO APPENDIX TITLES:

1-1 Exempt Sources 1-2 Limits for New Process Emission Sources 1-3 Limits for Existing Process Emission Sources 1-4 Limits for Existing Sources Using Solid Fuel Exclusively

Located Outside the Chicago Area 1-5 Emission Limits Motor Vehicle Refinishing 1-6 Emission Limits for Small, Medium, and Large HMIWIs 1-7 Operating Parameters for HMIWIs To Be Monitored and

Minimum Measurement and Recording Frequencies

1-8 Emission Limits for Rural HMIWIs

Page 31: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-15 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.2. MISSING CHECKLIST ITEMS

AE.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 32: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-16 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

AE.6. PERMITS/ NOTIFICATIONS/ EXEMPTIONS

AE.6.1.IL. Facilities must obtain construction and operating permits prior to the construction, modification, or operation of emission sources or air pollution control equipment (35 IAC 201.142, 201.143, 201.144, 201.146, and 201.148) [Moved in structural reorganization of AE.5 October 1999].

Verify that the facility does not cause or allow the construction or modification of any emission source or any new air pollution control equipment without first obtaining a construction permit from the Agency.

Verify that the facility does not cause or allow the operation of any emission source or new air pollution control equipment of a type for which a construction permit is required without first obtaining an operating permit from the Agency.

(NOTE: See Appendix 1-1 for the sources exempt from these permit requirements.)

Page 33: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-17 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

AE.7. MANAGEMENT/ ADMINISTRATIVE

AE.7.1.IL. Facilities with specific sources are required to develop an emission reduction plan (35 IAC 244.141, 244.142, and 244.143(a)) [Moved in structural reorganization of AE.5 October 1999].

Verify that the following sources develop an emission reduction plan to be implemented during an air episode:

- electric power generating stations burning fossil fuels - facilities having fuel combustion emission sources with a total rated heat

input in excess of 2.9 MW (10 MBtu/h) burning coal or fuel oil, other than those sources exempted from permit requirements

- facilities emitting more than 91 Mg/yr or 249 kg per operating day (100 tons per year or 550 lb per operating day) of sulfur dioxide, carbon monoxide, nitrogen oxides, particulate matter, organic material or of any other air contaminant designated by the Agency as harmful to human health

- governmental or commercial installations established primarily for the burning of refuse

- parking lots in major metropolitan areas having spaces for more than 200 vehicles--except for those lots predominantly serving residences, medical facilities, rail, bus and air transportation terminals, grocery stores and pharmacies, lots provided by employers primarily for their employees, and comparable lots as designated by the Agency

- fleet vehicle operations of 50 or more vehicles in a major metropolitan area except those used for delivery of grocery, pharmaceutical, and medical products

- local, state, and Federal government agencies employing more than 100 employees in a major metropolitan area

- state, county, and municipal offices which have responsibility for road repair in a major metropolitan area

- other governmental, industrial, or commercial establishments or activities classified by the Agency as significant direct or indirect sources of air contaminant emissions.

Verify that the emission reduction plan contains detailed steps that will be taken by

the facility to reduce the emission of air pollutants into the outdoor atmosphere during each stage of an air pollution episode.

(NOTE: The three stages of air pollution episodes are: yellow alert, red alert, and emergency.)

Verify that plans are submitted to:

- the Agency for Federal facilities in Illinois located outside of Cook County - the Cook County Department of Environmental Control for Federal facilities

located in Cook County and outside of the City of Chicago - the Chicago Department of Environmental Control for Federal facilities

Page 34: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-18 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

located within the City of Chicago.

AE.7.2.IL. Emission sources and air pollution control equipment must meet specific record keeping requirements (35 IAC 201.301) [Moved in structural reorganization of AE.5 October 1999].

Verify that the owner or operator of any emission source or air pollution control equipment maintains, at a minimum:

- records detailing all activities pursuant to any compliance program and project completion schedule

- records detailing all malfunctions, breakdowns, or startups - records of all monitoring and testing.

(NOTE: All records shall be made available to the Agency at any reasonable time.)

AE.7.3.IL. Emission sources and air pollution control equipment must meet specific reporting requirements (35 IAC 201.302) [Moved in structural reorganization of AE.5 October 1999].

Verify that the owner or operator of any emission unit or air pollution control equipment, unless specifically exempted, submits to the Agency as a minimum, annual reports detailing the nature, specific emission units and total annual quantities of all specified air contaminant emissions.

(NOTE: The Agency may require more frequent reports where necessary to accomplish the purposes of the Act and this Chapter.)

Page 35: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-19 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

AE.8. OPERATIONS

AE.8.1.IL. Facilities are prohibited from violating air pollution standards or limitations during the malfunction, breakdown, or startup of an emission source (35 IAC 201.149 and 201.263) [Moved in structural reorganization of AE.5 October 1999].

Verify that the facility does not operate an emission source during malfunction or breakdown of the emission source or related air pollution control equipment if the operation violates air pollution standards or limitations, unless specifically allowed to in the current operating permit.

Verify that the facility does not violate air pollution standards or limitations during startup unless a violation is allowed by the Agency in the current operating permit.

Verify that any facility that causes or allows the continued operation of an emission source during a malfunction or breakdown of the emission source or related air pollution control equipment, when the continued operation would cause a violation of standards or limitations, immediately reports the incident to the Agency by telephone, telegraph or such other method as constitutes the fastest available alternative (except if otherwise provided in the operating permit).

(NOTE: Thereafter, the facility must comply with all reasonable directives of the Agency with respect to the incident.)

AE.8.2.IL. Emission sources and air pollution control equipment must meet specific design standards (35 IAC 201.151) [Moved in structural reorganization of AE.5 October 1999].

Verify that the facility does not operate an emission source or air pollution control equipment without providing one or more stacks or vents that are designed to prevent the concentration of any air contaminants from:

- exceeding any applicable ambient air quality standard, either alone or in combination with air contaminants from other sources

- causing air pollution either alone or in combination with air contaminants from other sources

- exceeding emission standards and limitations.

(NOTE: This rule does not apply to emission sources, such as stock piles of particulate matter which, because of the disperse nature of such emission sources, cannot reasonably be expected to be emitted through a stack.)

Page 36: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-20 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

AE.9. EMISSIONS LIMITS

AE.9.1.IL. Facilities must not contribute to an exceed-ance of state ambient air quality regulations (35 IAC 201.141 and 210.142(b))) [Moved in structural reorganization of AE.5 October 1999].

Verify that the facility does not contribute to an exceedance of the secondary ambient air quality standards for sulfur oxides (as SO2) of a maximum 3 h concentration of 1300 m/m (0.5 ppm) (not to be exceeded more than once per year).

AE.9.2.IL. Emissions of particulate matter from all emission sources must be restricted (35 IAC 212.123 and 212.124(a) and (b)) [Moved in structural reorganization of AE.5 October 1999].

(NOTE: New fuel combustion emission sources are subject to more stringent stan-dards; see AE.15.1.IL.)

Verify that the facility does not cause or allow the emission of smoke or other particulate matter, with an opacity greater than 30 percent, into the atmosphere from any emission source other than those sources subject to the regulation for new fuel combustion emission sources.

(NOTE: The emission of smoke or other particulate matter from any emission source may have an opacity greater than 30 percent but not greater than 60 percent for a period or periods aggregating 8 min in any 60 min period, provided that the following conditions are met:

- the more opaque emission allowed during any 60 min period occurs from only one emission source located within a 305 m (1000 ft) radius from the center point of any other emission source

- the more opaque emissions allowed from each fuel combustion emission source are limited to three times in any 24 h period.)

(NOTE: This does not apply to the emissions of water or water vapor from an

emission source.)

(NOTE: This applies during times of startup, malfunction, and breakdown, except as provided in the operating permit.)

AE.9.3.IL. Facilities are required to restrict the emission of particulate matter from any new process emission source (35 IAC 212.321(a)) [Moved in

Verify that the facility does not cause or allow the emission of particulate matter into the atmosphere in any one hour period from any new process emission source which, either alone or in combination with the emission of particulate matter from all other similar new process emission sources on the premises, exceeds the allowable emission rates specified in Appendix 1-2.

Page 37: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-21 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

structural reorganization of AE.5 October 1999].

AE.9.4.IL. Facilities are required to restrict the emission of particulate matter from any existing process emission source (35 IAC 212.322(a)) [Moved in structural reorganization of AE.5 October 1999].

Verify that the facility does not cause or allow the emission of particulate matter into the atmosphere in any one hour period from any existing process emission source which, either alone or in combination with the emission of particulate matter from all other similar new or existing process emission sources on the premises, exceeds the allowable emission rates specified in Appendix 1-3.

AE.9.5.IL. Emissions of sulfur dioxide from any process emission source must meet specific restrictions (35 IAC 214.301 and 214.302) [Moved in structural reorganization of AE.5 October 1999].

Verify that the facility does not cause or allow the emission of sulfur dioxide into the atmosphere from any process emission source to exceed 2000 ppm.

(NOTE: This does not apply to processes designed to remove sulfur compounds from the flue gases of fuel combustion emission sources.)

AE.9.6.IL. Facilities are required to restrict the emission of NOx from any new industrial processes (35 IAC 217.301) [Moved in structural reorganization of AE.5 October 1999].

Verify that the facility does not cause or allow the emission of NOx into the atmosphere from any new process producing products of organic nitrations and/or oxidations using nitric acid, to exceed the following standards and limitations:

- 2.5 kg of NOx (expressed as nitrogen dioxide) per metric tonne of nitric acid (100 percent acid basis) used in new process (5.0 lb/tonne)

- visible emissions in excess of 5 percent opacity.

Verify that the facility does not cause or allow the emission of NOx into the atmosphere from any existing process, producing products of organic nitrations and/ or oxidations using nitric acid, o exceed 5.0 kg of NOx (expressed as nitrogen dioxide) per metric tonne of nitric acid (100 percent acid basis) used in new process (10.0 lb/ton).

(NOTE: This does not apply to any industrial process using less than 90.7 metric tons (100 tons) of nitric acid (100 percent acid basis) annually or which produces less than 907 kg (1 ton) of NOx (expressed as NO2) annually.)

Page 38: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-22 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.15. FUEL-BURNING EQUIPMENT

AE.15.1.IL. Facilities are required to restrict the emission of particulate matter from new fuel combustion emission sources (35 IAC 212.122 and 212.124(a) and (b)).

Verify that the facility does not cause or allow the emission of smoke or other particulate matter into the atmosphere from any new fuel combustion emission source with actual heat input greater than 73.2 MW (250 MBtu/h), having an opacity greater than 20 percent.

(NOTE: The emission of smoke or other particulate matter from any new fuel emission source may have an opacity greater than 20 percent but not greater than 40 percent for a period or periods aggregating 3 min in any 60-min period, provided that the following conditions are met:

- the more opaque emission allowed during any 60-min period occurs from only one emission source located within a 305-m (1000-ft) radius from the center point of any other emission source

- the more opaque emissions allowed from each fuel combustion emission source are limited to three times in any 24-h period.)

(NOTE: This does not apply to the emissions of water or water vapor from an

emission source.)

(NOTE: This applies during times of startup, malfunction, and breakdown, except as provided in the operating permit.)

AE.15.2.IL. Emissions of sulfur dioxide from large new fuel combustion emission source must be restricted (35 IAC 214.121).

Verify that the facility does not cause or allow the emission of sulfur dioxide into the atmosphere in any one hour period from any new fuel combustion emission source with actual heat input greater than 73.2 MW (250 MBtu/h), burning solid fuel exclusively, to exceed 1.86 kg of sulfur dioxide per MW-h (1.2 lb/MBtu) of actual heat input.

Verify that the facility does not cause or allow the emission of sulfur dioxide into the atmosphere in any one hour period from any new fuel combustion emission source with actual heat input greater than 73.2 MW (250 MBtu/h), burning liquid fuel exclusively, to exceed the following:

- 1.2 kg of sulfur dioxide per MW-h (0.8 lb/MBtu) of actual heat input when residual fuel oil is burned

- 0.46 kg of sulfur dioxide per MW-h (0.3 lb/MBtu) of actual heat input when distillate fuel oil is burned.

AE.15.3.IL. Emissions of Verify that the facility does not cause or allow the emission of SO2 into the

Page 39: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-23 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

sulfur dioxide from small new fuel combustion emission source must be restricted (35 IAC 214.122).

atmosphere in any one hour period from any new fuel combustion emission source with actual heat input smaller than, or equal to, 73.2 MW (250 MBtu/h), burning solid fuel exclusively, to exceed 2.79 kg of SO2 per MW-h (1.8 lb/MBtu) of actual heat input.

Verify that the facility does not cause or allow the emission of SO2 into the atmosphere in any 1 h period from any new fuel combustion emission source with actual heat input smaller than, or equal to, 73.2 MW (250 MBtu/h), burning liquid fuel exclusively, to exceed the following:

- 1.55 kg of SO2 per MW-h (1.0 lb/MBtu) of actual heat input when residual fuel oil is burned

- 0.46 kg of SO2 per MW-h (0.3 lb/MBtu) of actual heat input when distillate fuel oil is burned.

AE.15.4.IL. Facilities are required to restrict the emission of nitrogen oxides (NOx) from any new fuel combustion emission source (35 IAC 217.121).

Verify that the facility does not cause or allow the emission of NOx into the atmosphere in any one hour period from any new fuel combustion emission source with an actual heat input equal to or greater than 73.2 MW (250 MBtu/h) to exceed the following:

- 0.310 kg/MW-h (0.20 lb/MBtu) of actual heat input, for gaseous fossil fuel - 0.464 kg/MW-h (0.30 lb/MBtu) of actual heat input, for liquid fossil fuel - 0.464 kg/MW-h (0.30 lb/MBtu) of actual heat input, for dual gaseous and

liquid fossil fuel - 1.08 kg/MW-h (0.7 lb/MBtu) of actual heat input, for solid fossil fuel.

(NOTE: For fuel combustion emission sources burning simultaneously any combination of solid, liquid, and gaseous fossil fuels, an allowable emission rate is determined by he following equation:

E = (AG + BL + CS) Q Where:

E = Allowable nitrogen oxides emissions rate Q = Actual heat input derived from all fossil fuels G = Percent of actual heat input derived from gaseous fossil fuel L = Percent of actual heat input derived from liquid fossil fuel S = Percent of actual heat input derived from solid fossil fuel G + L + S = 100.0.)

AE.15.5.IL. Emissions of sulfur dioxide from any existing fuel combustion emission source that burns liquid fuel exclusively must

Verify that the facility does not cause or allow the emission of sulfur dioxide into the atmosphere in any one hour period from any existing fuel combustion source, burning liquid fuel exclusively, to exceed the following:

- 1.55 kg of sulfur dioxide per MW-h (1.0 lb/MBtu) of actual heat input when

Page 40: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-24 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

meet specific restrictions (35 IAC 214.161).

residual fuel oil is burned - 0.46 kg of sulfur dioxide per MW-h (0.3 lb/MBtu) of actual heat input when

distillate fuel oil is burned.

AE.15.6.IL. Emissions of sulfur dioxide from any fuel combustion emission source that burns simultaneously any combination of fuels must meet specific restrictions (35 IAC 214.162).

Verify that the facility does not cause or allow the emission of sulfur dioxide into the atmosphere in any one hour period from any fuel combustion emission source, burning simultaneously any combination of solid, liquid, and gaseous fuels, to exceed the allowable emission rate determined by the following equation:

E = AX + BY + CZ where:

E = allowable sulfur dioxide emission rate A = solid fuel sulfur dioxide emission standard which is applicable B = distillate oil sulfur dioxide emission standard C = residual fuel oil sulfur dioxide emission standard X = actual heat input from solid fuel Y = actual heat input from distillate fuel oil Z = actual heat input from residual fuel oil.

AE.15.7.IL. Emissions of carbon monoxide (CO) from any fuel combustion emission source must meet specific restrictions (35 IAC 216.121).

Verify that the facility does not cause or allow the emission of carbon monoxide (CO) into the atmosphere from any fuel combustion emission source with actual heat input greater than 2.9 MW (10 MBtu/h) to exceed 200 ppm, corrected to 50 percent excess air.

AE.15.8.IL. Emissions of particulate matter from any new fuel combustion source using solid fuel exclusively must meet specific restrictions (35 IAC 212.204) [Moved in structural reorganization of AE.5 October 1999].

Verify that the facility does not cause or allow the emission of particulate matter into the atmosphere from any new fuel combustion source using solid fuel exclu-sively to exceed 0.15 kg of particulate matter per MW-h (0.1 lb/MBtu) of actual heat input in any one hour period.

AE.15.9.IL. Emissions of particulate matter from existing coal-fired industrial boilers equipped with flue gas desulfurization systems must meet specific restrictions (35

Verify that the facility does not cause or allow the emission of particulate matter into the atmosphere from existing coal-fired industrial boilers equipped with flue gas desulfurization systems to exceed 0.39 kg of particulate matter per MW-h (0.25 lb/MBtu) of actual heat input in any one hour period.

Page 41: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-25 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

IAC 212.205) [Moved in structural reorganization of AE.5 October 1999].

AE.15.10.IL. Emissions of particulate matter from any fuel combustion source using liquid fuel exclusively must meet specific restrictions (35 IAC 212.206) [Moved in structural reorganization of AE.5 October 1999].

Verify that the facility does not cause or allow the emission of particulate matter into the atmosphere in any one hour period to exceed 0.15 kg of particulate matter per MW-h (0.10 lb/MBtu) of actual heat input from any fuel combustion emission source using liquid fuel exclusively.

AE.15.11.IL. Emissions of particulate matter from sources using more than one type of fuel must meet specific restrictions (35 IAC 212.207(a) and 212.208) [Moved in structural reorganization of AE.5 October 1999].

Verify that the facility, while simultaneously burning more than one type of fuel in a fuel combustion emission source, does not cause or allow the emission of par-ticulate matter into the atmosphere in any one hour period to exceed the amount determined the following equation:

E = AS + BL where:

E = Allowable emission rate; A = Solid fuel particulate emission standard which is applicable B = Constant determined from the table below S = Actual heat input from solid fuel L = Actual heat input from liquid fuel.

(NOTE: This standard may be applied to the aggregate of all fuel combustion emission sources vented to a common stack provided that after 26 January 1972: ductwork has not been modified so as to interconnect the existing fuel combustion emission sources; the actual heat input to any the existing fuel combustion emission source is not increased; and no new fuel combustion emission source is added to reduce the degree of control of emissions of particulate matter required by this regulation.)

AE.5.12.IL. Facilities are required to restrict the emission of particulate matter from any existing fuel combustion source using solid fuel exclusively (35 IAC 212.201, 212.202, and 212.203) [Moved in structural

Verify that facilities located in the Chicago MMA do not cause or allow the emission of particulate matter into the atmosphere from any existing fuel combustion source using solid fuel exclusively to exceed 0.15 kg of particulate matter per MW-h (0.10 lb/MBtu/h) of actual heat input in any one hour period.

Verify that facilities located outside the Chicago MMA do not cause or allow the emission of particulate matter into the atmosphere from any existing fuel combus-tion source using solid fuel exclusively to exceed the limitations specified in

Page 42: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-26 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

reorganization of AE.5 October 1999].

Appendix 1-4 in any one hour period.

(NOTE: Existing fuel combustion source using solid fuel exclusively may be exempt from this regulation if it meets the following requirements:

- emits in any one hour period up to, but not exceeding, 0.31 kg/MW-h (0.2 lb/MBtu), if, as of 14 April 1972, any of the following conditions are met:

- the emission source had an hourly emission rate based on original design or equipment performance test conditions, whichever is stricter, which was less than 0.31 kg/MW-h (0.20 lb/MBtu) of actual heat input, and the emission control of the source is not cause or allowed to degrade more than 0.077 kg/ MW-h (0.05 lb/MBtu) from the original design or acceptance performance test conditions

- the source was in full compliance with the terms and conditions of a variance granted by the Pollution Control Board (Board) sufficient to achieve an hourly emission rate less than 0.31 kg/MW-h (0.20 lb/MBtu), and construction has commenced on equipment or modifications prescribed under that program; and emission control of the source is not cause or allowed to degrade more than 0.077 kg/MW-h (0.05 lb/MBtu) from original design or equipment performance test conditions, whichever is stricter

- the emission source had an hourly emission rate based on original design or equipment performance test conditions, whichever is stricter, which was less than 0.31 kg/MW-h (0.20 lb/MBtu) of actual heat input, and the emission control of the source is not cause or allowed to degrade more than 0.077 kg/ MW-h (0.05 lb/MBtu) from that rate demonstrated by the most recent stack test, submitted to and accepted by the Agency prior to 1 April 1985.)

Page 43: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-27 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.25. MISCELLANEOUS INCINERATORS

AE.25.1.IL. Emissions of particulate matter from incinerators must meet specific limits (35 IAC 212.181 through 212.184).

Verify that the facility does not cause or allow the emission of particulate matter into the atmosphere from any incinerator burning more than 27.2 Mg (60,000 lb) of refuse per hour to exceed 115 mg (0.05 gr/scf) of effluent gases corrected to 12 percent carbon dioxide.

Verify that the facility does not cause or allow the emission of particulate matter into the atmosphere from any incinerator burning more than 0.907 Mg (2000 lb) but less than 27.2 Mg (60,000 lb) of refuse per hour to exceed 183 mg (0.08 gr/scf) of effluent gases corrected to 12 percent carbon dioxide.

Verify that the facility does not cause or allow the emission of particulate matter into the atmosphere from all other existing incinerators to exceed 458 mg (0.2 gr/ scf) of effluent gases corrected to 12 percent carbon dioxide.

Verify that the facility does not cause or allow the emission of particulate matter into the atmosphere from all other new incinerators to exceed 229 mg (0.1 gr/scf) of effluent gases corrected to 12 percent carbon dioxide.

(NOTE: Aqueous waste incinerators which, when corrected to 50 percent excess air for combined fuel and charge incineration, produce stack gas containing carbon dioxide dry-basis volume concentrations of less than 1.2 percent from the charge alone, are exempt from this regulation if all the following conditions are met:

- the emission of particulate matter into the atmosphere from any new or existing incinerator does not exceed 229 mg (0.1 grains per standard cubic foot (gr/scf)) dry basis, when corrected to 50 percent excess air for combined fuel and charge incineration

- the waste charge to the incinerator does not exceed 907 kg (2000 lb) per hour.)

(NOTE: Wood waste incinerators are exempt from this regulation if all the

following conditions are met: - the emission of particulate matter from the incinerator does not exceed 458

mg (0.2 gr/scf) of effluent gases corrected to 12 percent carbon dioxide - the location of the incinerator is not in a restricted area, and is more than 305

m (1000 ft) from residential or other populated areas - when it can be affirmatively demonstrated that no economically reasonable

alternative method of disposal is available.)

(NOTE: Explosive waste incinerators are exempt from this regulation if all the fol-lowing conditions are met:

- the incinerator burns explosives or explosive-contaminated waste exclusively - the incinerator burns 227 kg (500 lb) of waste per hour or less

Page 44: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-28 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- all incinerators on the same site operate a total of 6 h or less in any day - the incinerator was in existence prior to 6 December 1976, and is located in

Williamson County in Section 3, Township 9 South, Range 2 East of the Third Principal Meridian

- the facility does not cause or allow the emission of particulate matter into the atmosphere from any existing small explosive waste incinerator to exceed 7140 mg/kg (50 gr/lb) of combined waste and auxiliary fuel burned.)

AE.25.2.IL. Emissions of carbon monoxide (CO) from incinerators must meet specific restrictions (35 IAC 216.141 and 216.142).

Verify that the facility does not cause or allow the emission of carbon monoxide into the atmosphere from any incinerator to exceed 500 ppm, corrected to 50 percent excess air.

(NOTE: This does not apply to: - existing incinerators burning less than 907 kg (2000 lb) of refuse per hour

which are in compliance with 35 Ill. Adm. Code 212.181(c) (see above) - existing small explosive waste incinerators which meet the conditions of 35

Ill. Adm. Code 212.184(a) (see above)).

Page 45: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-29 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

MEDICAL WASTE INCINERATORS AE.30. General

Existing HMIWIs

(NOTE: The requirements of Part 229 apply to each individual hospital/medical/infectious waste incinerator (HMIWI) for which construction was commenced on or before 20 June 1996. These requirements do not apply to the following (35 IAC 229.110 and 229.112):

- an HMIWI during periods when only pathological waste, low-level radioactive waste, and/or chemotherapeutic waste is burned, provided the owner or operator of the combustor:

- notifies the Agency of its intention to operate pursuant to this operating scenario in its CAPP application

- keeps records on a calendar quarter basis of the periods of time when only pathological waste, low-level radioactive waste and/or chemotherapeutic waste is burned

- any co-fired combustor if the owner or operator: - provides the Agency and the EPA by 15 December 1999 with

certification of its status - provides an estimate of the relative amounts of hospital waste, medical/

infectious waste, and other fuels and wastes to be combusted; and - keeps records on a calendar quarter basis of the weight of hospital waste

and medical/infectious waste combusted, and the weight of all other fuels and wastes combusted at the co-fired combustor

- any hospital that does not operate an HMIWI but sends any of its hospital waste or medical/infectious waste to an offsite is subject only to the waste management plan requirement

- any combustor required to have a permit under section 3005 of the Solid Waste Disposal Act (SWDA)

- any municipal combustor which meets the applicability requirements under subpart Cb, Ea, or Eb of 40 CFR 60 (standards or guidelines for certain municipal waste combustors)

- any pyrolysis unit - cement kilns firing hospital waste and/or medical/infectious waste - any HMIWI subject to the Standards of Performance for

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After 20 June 1996, contained in Subpart Ec of 40 CFR 60.50c.)

AE.30.1.IL. Hospital/ medical/infectious waste incinerators (HMIWIs) which intend to permanently shut

(NOTE: These requirements apply to all owners or operators of HMIWIs that intend to permanently shut down their HMIWI as a means of complying with Part 299.)

Page 46: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-30 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

down must meet specific requirements (35 IAC 229.116) [Added June 2000].

Verify that the Agency was provided with written notice of the intention to permanently shut down the HMIWI on or before 15 November 1999.

Verify that one of the following affirmative steps are taken to demonstrate that the HMIWI has been rendered permanently inoperable by 15 by September 2000:

- weld the primary chamber door shut - dismantle the HMIWI - other means that reasonably demonstrate that the HMIWI is no longer

functional.

AE.30.2.IL. HMIWIs which started construction on or before 20 June 1996 must meet compliance requirements (35 IAC 229.115 and 229.120) [Added June 2000].

Verify that all HMIWIs not exempt (see NOTE at beginning of section) are in compliance with Part 229 (the requirements expressed in AE.30, AE.32, and AE.34) and operate pursuant to a CAAPP permit by 15 September 2000.

(NOTE: An owner or operator if HMIWI may have up to 15 September 2002 to be in compliance if they meet specific requirements including submission of a CAAPP application on or before 15 November 1999 requesting an extended compliance schedule.)

Verify that an HMIWI requesting an extension is in compliance with the compliance schedule outlined in its CAAPP application.

Verify that all owners or operators of HMIWIs (including those operating under a permit extension) are in full compliance with all of the HMIWI operator by 15 September 2000.

(NOTE: Any owner or operator of an HMIWI that fails to demonstrate compliance with Part 229 by 15 September 2002 must cease operation of the HMIWI until compliance is achieved.)

AE.30.3.IL. HMIWIs must comply with specific operating parameters (35 IAC 229.150)) [Added June 2000].

(NOTE: These requirements apply following the date on which the initial performance test is completed. They do not apply during performance tests.)

Verify that an HMIWI operating with any of the following meet the emission limits in Appendix 1-6:

- a dry scrubber followed by a fabric filter - a wet scrubber - dry scrubber followed by a fabric filter and a wet scrubber.

Verify that the HMIWI does not operate above any of the applicable maximum or below any of the applicable minimum operating parameter values specified in Appendix 1-7.

Page 47: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-31 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that all operating parameters are measured at all times, except during periods of startup, shutdown, and malfunction (calculated each hour as a 3-hour rolling average of the previous 3 operating hours).

(NOTE: For batch HMIWIs, the charge rate must be measured on a per batch basis.)

Verify that HMIWIs using air pollution control equipment other than a dry scrubber followed by a fabric filter, a wet scrubber, or dry scrubber followed by a fabric filter and a wet scrubber comply with the emission limits in Appendix 1-6.

Verify that an HMIWI does not operate above any applicable maximum or below any applicable minimum operating parameter values established in its CAAPP permit.

(NOTE: Rural HMIWIs must meet the emission limits in Appendix 1-8.)

AE.30.4.IL. HMIWIs using continuous emission system monitoring systems (CEMS) must meet specific operational requirements (35 IAC 229.152)) [Added June 2000].

(NOTE: A HMIWI may use a CEMS to demonstrate compliance with any of the emission limits in Appendix 1-6 if provided for in its permit.)

Verify that compliance with the applicable emission limits is determined by using a 12 hour rolling average, calculated each hour as the average of the previous 12 operating hours, not including startup, shutdown, or malfunction.

Verify that all CEMS are operated in accordance with the applicable procedures under Appendices B and F of 40 CFR 60, incorporated by reference.

AE.30.5.IL. HMIWIs equipped with a dry scrubber followed by a fabric filter are required to meet additional operating parameters (35 IAC 299.154) [Added June 2000].

Verify that the HMIWI is not operated above the maximum charge rate and below the minimum secondary chamber temperature (each measured on a 3-hr rolling average) simultaneously.

Verify that the HMIWI is not operated above the maximum fabric filter inlet temperature and below the minimum dioxin/furan sorbent flow rate (each measured on a 3-hr rolling average) simultaneously.

Verify that the HMIWI is not operated above the maximum charge rate and below the minimum HCl sorbent flow rate (each measured on a 3-hr rolling average) simultaneously.

Verify that the HMIWI is not operated above the maximum charge rate and below the minimum Hg sorbent rate (each measured on a 3-hr rolling average) simultaneously.

Verify that the facility does not use the bypass stack except during startup,

Page 48: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-32 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

shutdown, or malfunction.

(NOTE: A HMIWI may conduct a repeat performance test within 30 days of violation of applicable operating parameters to demonstrate that the facility is not in violation of the applicable emission limit.)

AE.30.6.IL. HMIWIs equipped with a wet scrubber are required to meet additional operating parameters (35 IAC 229.156) [Added June 2000].

Verify that the HMIWI is not operated above the maximum charge rate and below the minimum pressure drop across the wet scrubber or below the minimum horsepower or amperage to the system (each measured on a 3-hr rolling average) simultaneously.

Verify that the HMIWI is not operated above the maximum charge rate and below the minimum secondary chamber temperature (each measured on a 3-hr rolling average) simultaneously.

Verify that the HMIWI is not operated above the maximum charge rate, below the minimum secondary chamber temperature, and below the minimum scrubber liquor flow rate (each measured on a 3-hr rolling average) simultaneously.

Verify that the HMIWI is not operated above the maximum charge rate and below the minimum scrubber liquor pH (each measured on a 3-hr rolling average) simultaneously.

Verify that the HMIWI is not operated above the maximum flue gas temperature and above the maximum charge rate (each measured on a 3-hr rolling average) simultaneously.

Verify that the facility does not use the bypass stack except during startup, shutdown, or malfunction.

(NOTE: A facility may conduct a repeat performance test within 30 days of violation of applicable operating parameters to demonstrate that the facility is not in violation of the applicable emission limit.)

AE.30.7.IL. HMIWIs equipped with a dry scrubber followed by a fabric filter and a wet scrubber are required to meet additional operating parameters (35 IAC 229.158) [Added June 2000].

Verify that the HMIWI does not operate above the maximum charge rate and below the minimum secondary chamber temperature (each measured on a 3-hr rolling average) simultaneously.

Verify that the HMIWI does not operate above the maximum fabric filter inlet temperature, above the maximum charge rate and below the minimum dioxin/furan sorbent flow rate (each measured on a 3-hr rolling average) simultaneously.

Verify that the HMIWI does not operate above the maximum charge rate and below the maximum scrubber liquor pH (each measured on a 3-hr rolling average)

Page 49: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-33 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

simultaneously.

Verify that the HMIWI does not operate above the maximum charge rate and below the minimum Hg sorbent flow rate (each measured on a 3-hr rolling average) simultaneously.

Verify that the facility does not use the bypass stack except during startup, shutdown, or malfunction.

(NOTE: A facility may conduct a repeat performance test within 30 days of violation of applicable operating parameters to demonstrate that the facility is not in violation of the applicable emission limit.)

AE.30.8.IL. Rural HMIWIs must meet specific operating requirements (35 IAC 229.126 and 229.160) [Added June 2000].

(NOTE: These requirements apply following the date on which the initial performance test is completed or 15 September 2000 whichever date came first.)

Verify that the owners or operators of rural HMIWI do not operate their HMIWI either above the maximum charge rate or below the minimum secondary chamber temperature at all times, except during periods of startup or shutdown (calculated each hour as a 3-hour rolling average of the previous 3 operating hours).

Verify that the rural HMIWI is not operated above the maximum charge rate and below the minimum secondary chamber temperature (calculated as a 3-hour rolling average) simultaneously.

(NOTE: The simultaneous operation of a rural HMIWI above the maximum charge rate and below the minimum secondary chamber temperature (calculated as a 3-hour rolling average) constitute a violation of the PM, CO and dioxin/furan emission limits.)

Verify that the rural HMIWI meets the emission limits in Appendix 1-8 except as specified in a CAAPP.

AE.30.9.IL. HMIWIs must have a trained qualified operator onsite (35 IAC 229.170)[Added June 2000].

Verify that no HMIWI is operated unless a trained and qualified HMIWI operator is available on-site to operate or supervise the operation of the HMIWI.

Verify that HMIWI operators have obtained qualification by:

- completion of a training course described above, and - either 6-mo experience as an HMIWI operator, 6-mo experience as a direct

supervisor of an HMIWI operator, or completion of at least two burn cycles under the observation of two qualified HMIWI operators.

Verify that the training program includes an examination designed by the

instructor, provides references covering all the course topics, and consists of at

Page 50: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-34 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

least 24 hours of training covering the following subjects:

- work safety procedures - pre-startup procedures - environmental concerns, including pathogen destruction and types of

emissions - basic combustion principles, including combustion byproducts - instruction in the proper operation of the same type of incinerator that will be

used by the operator, including proper startup, waste charging, and shutdown procedures

- combustion controls and monitoring - operation of air pollution control equipment and factors affecting

performance - methods for monitoring pollutants, both by CEMS and by monitoring of

HMIWI and air pollution control device operating parameters, and monitoring instrument calibration procedures

- inspection and maintenance of an HMIWI, air pollution control equipment, and CEMS

- corrective measures to remedy malfunctions and conditions that may lead to malfunction

- characteristics of and proper handling procedures for bottom and fly ash - recordkeeping procedures - applicable Federal, State, and local regulations.

(NOTE: Qualification is valid from the date on which the examination is passed or the completion of the required experience, whichever is later.)

Verify that HMIWI operators have maintained qualification by completing and passing an annual review or refresher course of at least 4 h covering, at a minimum, the following:

- update of applicable regulations - proper incinerator operation, including startup and shutdown procedures - proper incinerator inspection and maintenance - responses to malfunctions or conditions that may lead to malfunction - discussion of operating problems encountered by attendees.

(NOTE: A lapsed qualification must be renewed by one of the following methods:

- for a lapse of less than 3 yr, the HMIWI operator must complete and pass a standard annual refresher course as described above

- for a lapse of 3 yr or more, the HMIWI operator must complete and pass a training course as described above. )

Page 51: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-35 Air Emissions Management

Page 52: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-36 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

MEDICAL WASTE INCINERATORS AE.32. Monitoring

Existing HMIWIs

(NOTE: The requirements of Part 229 apply to each individual hospital/medical/infectious waste incinerator (HMIWI) for which construction was commenced on or before 20 June 1996. These requirements do not apply to the following (35 IAC 229.110 and 229.112):

- an HMIWI during periods when only pathological waste, low-level radioactive waste, and/or chemotherapeutic waste is burned, provided the owner or operator of the combustor:

- notifies the Agency of its intention to operate pursuant to this operating scenario in its CAPP application

- keeps records on a calendar quarter basis of the periods of time when only pathological waste, low-level radioactive waste and/or chemotherapeutic waste is burned

- any co-fired combustor if the owner or operator: - provides the Agency and the EPA by 15 December 1999 with

certification of its status - provides an estimate of the relative amounts of hospital waste, medical/

infectious waste, and other fuels and wastes to be combusted; and - keeps records on a calendar quarter basis of the weight of hospital waste

and medical/infectious waste combusted, and the weight of all other fuels and wastes combusted at the co-fired combustor

- any hospital that does not operate an HMIWI but sends any of its hospital waste or medical/infectious waste to an offsite is subject only to the waste management plan requirement

- any combustor required to have a permit under section 3005 of the Solid Waste Disposal Act (SWDA)

- any municipal combustor which meets the applicability requirements under subpart Cb, Ea, or Eb of 40 CFR 60 (standards or guidelines for certain municipal waste combustors)

- any pyrolysis unit - cement kilns firing hospital waste and/or medical/infectious waste - any HMIWI subject to the Standards of Performance for

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After 20 June 1996, contained in Subpart Ec of 40 CFR 60.50c.)

AE.32.1.IL. HMIWIs must use specific methods and procedures for performance testing (35 IAC 229.142,

(NOTE: These requirements apply during all performance tests.

Verify that the owner or operator of an HMIWI provides the facilities for emission testing specified in 40 CFR 60.8(e), incorporated by reference.

Page 53: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-37 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

229.144, and 229.164) [Added June 2000].

testing specified in 40 CFR 60.8(e), incorporated by reference.

Verify that, when conducting a performance test for an HMIWI, the owner or operator meets the following requirements:

- test an HMIWI at the waste charging rate specified in its permit or, if no permit has been issued, in its permit application

- burn representative waste streams that are typically combusted in that HMIWI

- conduct testing during periods that are inclusive of maximum emissions of the HMIWI and not during periods of startup, malfunction, or shutdown; and

- weigh the amount of waste combusted for each run of the performance test before charging the waste to an HMIWI to within 1.0 percent accuracy.

Verify that the owner or operator of an HMIWI submits a test plan to the Agency at least 45 days before conducting a performance test.

Verify that the owner or operator of an HMIWI gives the Agency 5 days written notice prior to actually conducting any required performance testing.

Verify that the test plan is followed when conducting a performance test.

Verify that a bypass stack is not utilized during a performance test.

(NOTE: Any use of a bypass stack during a performance test will invalidate the results of that run.)

(NOTE: The owner or operator of an HMIWI may conduct another performance test within 30 days after exceeding an applicable operating parameter value in order to demonstrate that an HMIHI is not in violation of the applicable emission limits.)

Verify that the owner or operator of an HMIWI notifies the Agency in writing at least 21 days before the date of any optional performance test.

Verify that the owner or operator of an HMIWI notifies the Agency in writing of its intent to proceed with the optional performance test 5 days prior to conducting the test.

Verify that any optional performance test uses the same approved performance test plan that was used for the performance test in which the violated operating parameter values were established.

AE.32.2.IL. HMIWIs must meet performance testing requirements (35 IAC 229.142 and 229.144))

Verify that an initial performance test was conducted by 15 September 2000.

Verify that the initial performance tests for all pollutants limited in Appendix 1-6 and Appendix 1-8.

Page 54: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-38 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

[Added June 2000]. and Appendix 1-8.

(NOTE; During the initial performance test, rural HMIWIs are not required to test for HCl, Pb or Cd.)

Verify that, if an HMIWI is equipped with a dry scrubber followed by a fabric filter, a wet scrubber, or a dry scrubber followed by a fabric filter and wet scrubber, the appropriate maximum and minimum operating parameter values indicated in Appendix 1-7 are used for the initial performance test.

Verify that, if air pollution control equipment other than a dry scrubber followed by a fabric filter, a wet scrubber, or dry scrubber followed by a fabric filter and a wet scrubber is used to comply with the emission limits, the initial performance test is conducted using site-specific operating parameters (established by the Agency in a construction permit and approved by USEPA) to demonstrate compliance.

(NOTE: Rural HMIWI, must establish the maximum charge rate and minimum secondary chamber temperature as site-specific parameters during the initial performance test, provided that the performance test demonstrates that the HMIWI is in compliance with the emission limits.)

(NOTE: The owner or operator of an HMIWI may conduct a repeat performance test at any time to establish new site specific operating values for the HMIWI.)

Verify that new site specific operating parameter values used to repeat a performance test are not relied upon until approved by the Agency as a permit condition.

(NOTE: The Agency or the USEPA may request that the owner or operator of an HMIWI conduct a new performance test at any time.)

AE.32.3.IL. HMIWIs must conduct annual performance tests (35 IAC 229.146 and 229.148) [Added June 2000].

(NOTE: These requirements go into effect following the date on which the initial performance test is completed.) (NOTE: See Appendix for 1-6 and 1-8 for emission limits.) Verify that the an annual opacity test is conducted by 15 September of each year. Verify that all owners or operators of small, medium, or large HMIWIs conduct an annual performance test, by 15 September of each year, to determine compliance with the PM, CO and HCl emission limits . (NOTE: If all 3 annual performance tests over a 3-year period indicate compliance with the emission limits for PM, CO, or HCl, the owner or operator of an HMIWI

Page 55: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-39 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

may forego a performance test for that pollutant during the next 2 years. If the next performance test conducted every third year indicates compliance with the emission limits for PM, CO, or HCl, the owner or operator of an HMIWI may forego a performance test for that pollutant for an additional 2 ears from the date of the previous performance test. If any performance test indicates noncompliance with the respective emission limit, the owner or operator of an HMIWI must conduct a performance test for that pollutant annually until all annual performance tests over a 3-year period indicate compliance with the respective emission limits.)

AE.32.4.IL. Samm, Medium, and Large HMIWIs meet monitoring requirements (35 IAC 229.166) [Added June 2000].

Verify that, once the initial performance test has been performed, and the site-specific minimum and maximum operating parameter values have been established, the owner or operator of a small, medium or large HMIWI continuously monitor those parameters.

Verify that HMIWIs install, calibrate according to manufacturer's specifications, maintain, and operate devices or establish methods for monitoring the applicable maximum and minimum operating parameters.

Verify that the monitoring devices or methods measure and record values for these operating parameters at the frequencies indicated in Appendix 1-7 at all times, except during periods of startup and shutdown.

Verify that HMIWIs install, calibrate according to manufacturer's specifications, maintain, and operate a device or establish a method for identifying the use of the bypass stack, including date, time, and duration of use.

Verify that, if control equipment other than a dry scrubber followed by a fabric filter, a wet scrubber, or a dry scrubber followed by a fabric filter and a wet scrubber is used to comply with the emission limits, the HMIWI installs, calibrates according to manufacturer's specifications, maintains, and operates the equipment necessary to monitor the approved site-specific operating parameters.

Verify that monitoring data is recorded at all times during HMIWI operation, except during the periods of monitoring equipment malfunction, calibration, or repair.

Verify that, at a minimum, valid monitoring data is recorded for 75 percent of the operating hours per day and for 90 percent of the operating days per calendar quarter that an HMIWI is combusting hospital waste or medical/infectious waste.

AE.32.5.IL. Rural HMIWIs must install, calibrate, maintain, and operate monitoring devices to monitor operating parameters at

Verify that rural HMIWIs install, calibrate (to manufacturers' specifications), maintain, and operate a device for measuring and recording the temperature of the secondary chamber on a continuous basis, the output of which is recorded, at a minimum, once every minute throughout operation.

Page 56: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-40 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

operating parameters at applicable frequencies (35 IAC 229.168)) [Added June 2000].

Verify that rural HMIWIs install, calibrate (to manufacturers' specifications), maintain, and operate a device which automatically measures and records the date, time, and weight of each charge fed into the HMIWI.

Verify that rural HMIWIs obtain monitoring data at all times during HMIWI operation except during periods of monitoring equipment malfunction, calibration, or repair.

Verify that, at a minimum, valid monitoring data is obtained for 75 percent of the operating hour per day and for 90 percent of the operating hour per calendar quarter that the designated facility is combusting hospital waste and/or medical/infectious waste.

AE.32.6.IL. Rural HMIWIs must comply with specific inspection requirements (35 IAC 229.162) [Added June 2000].

Verify that, no later than 15 September 2000 and annually thereafter (no more than 12 mo following the previous annual equipment inspection) an equipment inspection is performed where the rural HMIWI:

- inspects all burners, pilot assemblies, and pilot sensing , cleaning the pilot flame sensor, as necessary

- inspects primary and secondary chamber combustion air flow, adjusting as necessary

- inspects hinges and door latches, lubricating as necessary - inspects dampers, fans, and blowers - inspects HMIWI door and door gaskets for proper sealing - inspects all HMIWI motors - inspects primary chamber refractory lining, cleaning, repairing, or replacing

the lining, as necessary - inspects incinerator shell for corrosion or hot spots - inspects secondary/tertiary chamber and stack, cleaning as necessary - inspects mechanical loader, including limit switches, where applicable - visually inspects waste bed (grates), repairing or sealing, as necessary - inspects air pollution control devices(s) for proper operation, where

applicable - inspects waste heat boiler systems, where applicable - inspects all bypass stack components - inspects calibration of thermocouples, sorbent feed systems, and monitoring

equipment - general inspection of all equipment to ensure that it is maintained in good

operating condition. Verify that all maintenance, adjustments, or repairs identified during the required inspection are completed within 10 days after the inspection, unless the Agency approves, in writing, a longer period of time for any repairs.

Page 57: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-41 Air Emissions Management

Page 58: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-42 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

MEDICAL WASTE INCINERATORS AE.34 Reporting/Record keeping Requirements

Existing HMIWIs

(NOTE: The requirements of Part 229 apply to each individual hospital/medical/infectious waste incinerator (HMIWI) for which construction was commenced on or before 20 June 1996. These requirements do not apply to the following (35 IAC 229.110 and 229.112):

- an HMIWI during periods when only pathological waste, low-level radioactive waste, and/or chemotherapeutic waste is burned, provided the owner or operator of the combustor:

- notifies the Agency of its intention to operate pursuant to this operating scenario in its CAPP application

- keeps records on a calendar quarter basis of the periods of time when only pathological waste, low-level radioactive waste and/or chemotherapeutic waste is burned

- any co-fired combustor if the owner or operator: - provides the Agency and the EPA by 15 December 1999 with

certification of its status - provides an estimate of the relative amounts of hospital waste, medical/

infectious waste, and other fuels and wastes to be combusted; and - keeps records on a calendar quarter basis of the weight of hospital waste

and medical/infectious waste combusted, and the weight of all other fuels and wastes combusted at the co-fired combustor

- any hospital that does not operate an HMIWI but sends any of its hospital waste or medical/infectious waste to an offsite is subject only to the waste management plan requirement

- any combustor required to have a permit under section 3005 of the Solid Waste Disposal Act (SWDA)

- any municipal combustor which meets the applicability requirements under subpart Cb, Ea, or Eb of 40 CFR 60 (standards or guidelines for certain municipal waste combustors)

- any pyrolysis unit - cement kilns firing hospital waste and/or medical/infectious waste - any HMIWI subject to the Standards of Performance for

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After 20 June 1996, contained in Subpart Ec of 40 CFR 60.50c.)

AE.34.1.IL. HMIWIs must meet reporting requirements

Verify that the facility manager and the responsible official for the HMIWI certifies each required report.

Page 59: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-43 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

(IL 35 229.184 (a) through (f)) [Added June 2000].

certifies each required report.

Verify that the owner or operator of an HMIWI submits to the Agency the results of any performance test conducted on the HMIWI within 60 days after conducting the performance test.

Verify that the information submitted with the initial performance test required by Section 229.142 includes:

- the test data and values for the site-specific operating parameters established for an HMIWI

- copy of the waste management plan (see 229.176 for details). Verify that all owners or operators of HMIWIs submit the following information to the Agency by 15 September 2001 and by 15 September of each year thereafter:

- the values for site-specific operating parameters - the highest maximum operating parameter and the lowest minimum operating

parameter, as applicable, for each operating parameter, recorded for the Calendar year being reported and for the calendar year preceding the year being reported

- any information recorded about missing data, identification of malfunctions, or exceedences of emission rates or operating parameters (pursuant to Section 229.182(a)(3) through (5)) for the calendar year being reported and for the calendar year preceding the year being reported;

- if no exceedences or malfunctions were recorded for the calendar year being reported, a statement that no exceedences occurred during the reporting period; and

- any use of the bypass stack, the duration of use, the reason for malfunction, and the corrective actions taken.

Verify that, once a HMIWI is issued a CAAPP permit, the owner or operator submits these reports semi-annually.

(NOTE: The first semiannual reporting period ends on 15 March of each year and the second semiannual reporting period ends on 15 September of each year.)

AE.34.2.IL. HMIWIs must maintain specific documentation at the facility (35 IL 229.172) [Added June 2000].

Verify that the following information is maintained on-site for the use and reference of HMIWI operators:

- summary of the applicable requirements - a description of basic combustion theory applicable to HMIWIs - procedures for receiving, handling, and charging waste - procedures for startup and shutdown of the HMIWI - procedures for maintaining proper combustion air supply levels - procedures for operating the HMIWI and associated air pollution control

Page 60: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-44 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

systems within the established standards - procedures for responding to periodic malfunction or conditions that may

lead to malfunction - procedures for monitoring HMIWI emissions - recordkeeping and reporting procedures - procedures for handling ash

Verify that a program has been established that requires all HMIWI operators to review annually the information in required documentation.

(NOTE: The initial review of the information in all required documentation shall be conducted by 16 September 2000 or prior to assumption of responsibilities affecting HMIWI operation, whichever date is later.)

Verify that subsequent reviews of the information in all required documentation are conducted annually.

Verify that all required documentation is kept in a readily accessible location to all HMIWI operators.

AE.34.3.IL. HMIWIs must meet recordkeeping requirements (35 IAC 229.182 (a), (f) and (g)) [Added June 2000].

(NOTE: Required records must be maintained onsite in either a paper copy or an electronic format, unless an alternative format has been approved by the Agency in a permit. All records must be made available to the Agency upon request.)

Verify that all required records are maintained for 5 yr .

Verify that the following data (if applicable) is maintained with the calendar date for each record:

- concentrations of all applicable pollutants listed in Section 229.125(b) or 229.126(b) (as determined by the CEMS, if applicable) and any measurements of opacity

- HMIWI charge dates, times and weights, and hourly charge rates - if a fabric filter is used, the fabric filter inlet temperatures during each minute

of operation - the amount and type of dioxin/furan sorbent used during each hour of

operation - the amount and type of Hg sorbent used during each hour of operation - the amount and type of HCl sorbent used during each hour of operation - the secondary chamber temperatures recorded during each minute of

operation - the liquor flow rate to the wet scrubber inlet during each minute of operation - the horsepower or amperage to the wet scrubber during each minute of

operation - any pressure drop across the wet scrubber system during each minute of

operation

Page 61: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-45 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- the temperature at the outlet from the wet scrubber during each minute of operation

- the pH at the inlet to the wet scrubber during each minute of operation - identification of any use of the bypass stack, including dates, times, and the

duration of such use - all operating parameter data monitored for control equipment other than a dry

scrubber followed by a fabric filter, a wet scrubber, or a dry scrubber followed by a fabric and a wet scrubber.

- identification of any calendar days for which data on emission rates or operating parameters have not been obtained, with an identification of the emission rates or operating parameters not measured, reasons for not obtaining data, and a description of the corrective actions taken

- identification of any malfunctions, including the calendar date, the time and duration, and a description of the malfunction and of the corrective action taken to remedy it

- identification of calendar days for which data on emission rates or operating parameters exceeded the applicable limits, with a description of the exceedences, reasons for such exceedences, and a description of the corrective actions taken;

- the results of the initial, annual, and any other performance tests - records of calibration of any required monitoring devices - identification of the names of all HMIWI operators who have met the criteria

for qualification under Section 229.170 of this Part, including documentation of training with dates of training and all required reviews.

AE.34.4.IL. HMIWIs or co-fired combustors claiming an exemption must meet recordkeeping requirements (35 IAC 229.182 (b) through (d), and (f) and (g)) [Added June 2000].

(NOTE: Required records must be maintained onsite in either a paper copy or an electronic format, unless an alternative format has been approved by the Agency in a permit. All records must be made available to the Agency upon request.)

Verify that the owner or operator of an HMIWI claiming an exemption from the emission limits when it combusts only pathological waste, low-level radioactive waste, or chemotherapeutic waste keeps contemporaneous records identifying each period of time when only pathological waste, low-level radioactive waste, or chemotherapeutic waste is burned, including the calendar date and duration of such periods.

Verify that the owner or operator of an HMIWI claiming an exemption because it combusts only low-level radioactive waste, or chemotherapeutic waste keeps records on a calendar quarter basis demonstrating that only pathological waste, low-level radioactive waste, or chemotherapeutic waste is burned.

Verify that the owner or operator of a co-fired combustor claiming an exemption from the emission limits maintains records on a calendar quarter basis of the relative weight of hospital waste and/or medical/infectious waste, and of all other

Page 62: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-46 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

fuels or waste combusted.

Verify that all required records are maintained onsite for a period of 5 years.

AE.34.5.IL. Rural HMIWIs must meet specific record keeping requirements (35 IAC 229.182 (e) through (g) [Added June 2000].

Verify that the owner or operator of each rural HMIWI maintains records of the required annual equipment inspections, any required maintenance, and any repairs not completed within 10 days after an inspection or the time frame established by the Agency.

Verify that all required records are maintained onsite for a period of 5 years.

(NOTE: Required records must be maintained onsite in either a paper copy or an electronic format, unless an alternative format has been approved by the Agency in a permit. All must be made available to the Agency upon request.).

AE.34.6.IL. Rural HMIWIs must meet specific reporting requirements (35 IAC 229.184 (a) and (e)) [Added June 2000].

Verify that the facilities manager and the responsible official for the HMIWI certifies each required report.

Verify that the owner or operator of an HMIWI submits to the Agency the results of any performance test conducted on the HMIWI within 60 days after conducting the performance test.

Verify that the information submitted with the initial performance test required by Section 229.142 includes:

- the test data and values for the site-specific operating parameters established for an HMIWI

- copy of the waste management plan. Verify that all owners or operators of HMIWIs submits the following information to the Agency by 15 September 2001 and by 15 September of each year thereafter:

- the values for site-specific operating parameters - the highest maximum operating parameter and the lowest minimum operating

parameter, as applicable, for each operating parameter, recorded for the Calendar year being reported and for the calendar year preceding the year being reported

- any information recorded about missing data, identification of malfunctions, or exceedences of emission rates or operating parameters (pursuant to Section 229.182(a)(3) through (5)) for the calendar year being reported and for the calendar year preceding the year being reported;

- if no exceedences or malfunctions were recorded for the calendar year being reported, a statement that no exceedences occurred during the reporting period; and

- any use of the bypass stack, the duration of use, the reason for malfunction,

Page 63: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-47 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

and the corrective actions taken.

AE.34.7.IL. HMIWIs accepting waste generated off-site must meet specific information requirements (35 IAC 229.180) [Added June 2000].

Verify that the owner or operator of any HMIWI that accepts hospital waste or medical/infectious waste generated off-site provides the hospital, medical or infectious waste customers with written information at least once a year concerning the availability of waste management practices for reducing the volume and toxicity of waste to be incinerated.

Verify that the owner or operator of any HMIWI that accepts hospital waste or medical/infectious waste generated off-site submits to the Agency a waste management plan (see 229.176 for details) that outlines the efforts that will be undertaken to distribute the above required information and identifies the information that will be distributed.

Verify that paper or electronic copies of the materials disseminated are made available to the Agency upon written request.

AE.34.8.IL. Hospitals using onsite incinerators must submit waste management plans (35 IL 229.176) [Added June 2000].

(NOTE: Hospitals transporting waste offsite to an HMIWI must meet the requirements found in SO.105.4.IL.)

Verify that the hospitals using onsite incinerators have prepared a waste management plan.

Verify that the plan outlines technically and economically feasible policies and practices for reducing the amount and toxicity of hospital and medical/infectious waste incinerated at the hospital.

Verify that the waste management plan includes the following components:

- the name and location of the facility - a written policy statement setting forth management support for waste

management and implementation of the plan - a statement of goals for reducing the volume and toxicity of waste, expressed

numerically where feasible - identification of the staff responsible for development and implementation of

the plan, as well as a description of their roles and responsibilities - a description of communication and education programs to make employees

aware of the waste management program and their responsibilities - a summary of existing waste management policies and practices - identification of technically and economically feasible waste management

policies and practices to be implemented and, where practical, a schedule for the implementation of the selected measures

- procedures for tracking implementation of the plan and progress toward achieving the goals.

Page 64: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-48 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that the waste management plan is updated every 5 yr to coincide with either the issuance or renewal of the facility's CAAPP permit.

Verify that a waste management progress report is submitted annually to the Agency along with the annual emission report.

Verify that the progress report includes the following elements:

- a description of progress made during the previous calendar year toward meeting the goals established in the plan;\

- a summary of the waste management practices that were implemented - any amendments to the plan along with a brief explanation of the need for the

amendments. (NOTE: Upon written request, the affected hospital must make the waste management plan and annual progress reports available for public review during normal business hours.)

AE.34.9.IL. HMIWIs must submit waste management plans (35 IL 229.181)[Added June 2000].

(NOTE: These requirements apply to HMIWIs other than hospitals using onsite incinerators or transporting their waste offsite to an HMIWWI.)

Verify that owner or operator of an HMIWI conducts an assessment of its current waste management program and submits a waste management plan to the Agency, with the initial performance test.

Verify that the waste management plan identifies additional technically and economically feasible measures for reducing the volume and toxicity of the waste to be incinerated, and, where practical, outlines a schedule for the implementation of the selected measures.

Verify that in identifying additional technically and economically feasible waste management practices, the following are considered:

- segregating waste streams - phasing out the use of products containing toxic materials - reusing products and equipment - reducing the use of packaging and disposable items - collecting recyclable materials - improving inventory control, training, and housekeeping practices.

Verify that in assessing its current waste management practices, the facility considers technical information on alternative waste management practices, such as the American Hospital Association publication entitled An Ounce of Prevention; Waste Management Strategies for Health Care Facilities.

Page 65: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-49 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that the waste management plan is updated every 5 years to coincide with either the issuance or renewal of the facility's CAAPP permit.

Page 66: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-50 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.55. GASOLINE AND FUELS

AE.55.1.IL. Gasoline in the Chicago Area must meet volatility standards (35 IAC 218.585) [Added May 1999].

Verify that the facility does not sell, dispense, supply, or transport for use in Illinois gasoline whose Reid vapor pressure exceeds the limitations set forth in this checklist item during the regulatory control periods, (1 May to 15 September for retail outlets, wholesale purchaser-consumer, operations, and all other operations).

Verify that the Reid vapor pressure of gasoline, a measure of its volatility, does not exceed 9.0 psi (62.07 kPa) during the regulatory control period in 1995 and each year thereafter.

Verify that the Reid vapor pressure of ethanol blend gasolines does not exceed 9.0 psi (62.07 kPa) by more than 1.0 psi (6.9 kPa).

(NOTE: Notwithstanding this limitation, blenders of ethanol blend gasolines whose Reid vapor pressure is less than 1.0 psi above the base stock gasoline immediately after blending with ethanol are prohibited from adding butane or any product that will increase the Reid vapor pressure of the blended gasoline.)

AE.55.2.IL. Gasoline in the Metro East Area must meet volatility standards (35 IAC 219.585) [Added May 1999].

Verify that the facility does not sell, dispense, supply, or transport for use in Illinois gasoline whose Reid vapor pressure exceeds the limitations set forth in this checklist item during the regulatory control periods, (1 June to 15 September for retail outlets, wholesale purchaser-consumer, operations, and all other operations).

Verify that the Reid vapor pressure of gasoline, a measure of its volatility, does not exceed 7.2 psi (49.68 kPa) during the regulatory control period in 1990 and each year thereafter.

Verify that the Reid vapor pressure of ethanol blend gasolines having at least 9 percent but not more than 10 percent ethyl alcohol by volume of the blended mixture, does not exceed 7.2 psi (49.68 kPa) by more than 1.0 psi (6.9 kPa).

(NOTE: Notwithstanding this limitation, blenders of ethanol blend gasolines whose Reid vapor pressure is less than 1.0 psi above the base stock gasoline immediately after blending with ethanol are prohibited from adding butane or any product that will increase the Reid vapor pressure of the blended gasoline.)

Page 67: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-51 Air Emissions Management

Page 68: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-52 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.60. PRINTING PRESSES AND GRAPHIC ARTS

AE.60.1.IL. Emissions of volatile organics from flexographic and rotogravure printing presses must be controlled (35 IAC 215.401).

Verify that no owner or operator of a packaging rotogravure, publication rotogravure or flexographic printing press employing solvent-containing ink causes or allows the operation of such press unless:

- the volatile fraction of ink as it is applied to the substrate contains 25 percent or less by volume of organic solvent and 75 percent or more by volume of water; or

- the volatile fraction of an ink as it is applied to the substrate, less water, is 40 percent or less by volume; or

- the owner or operator installs and operates: - a carbon adsorption system which reduces the volatile organic

emissions from the capture system by at least 90 percent by weight; or - an afterburning system which oxidizes at least 90 percent of the

captured nonmethane volatile organic materials (measured as total combustible carbon) to carbon dioxide and water; or

- an alternative volatile organic material emission reduction system demonstrated to have at least a 90 percent overall reduction efficiency and approved by the Agency; and a capture system.

(NOTE: These limitations do not apply to any facility whose aggregate

uncontrolled rotogravure and/or flexographic printing press emissions of volatile organic material are limited by operating permit conditions to 907 Mg (1000 tons) per year or less in the absence of air pollution control equipment or whose actual emissions in the absence of air pollution control equipment would be less than or equal to 907 Mg (1000 tons) per year when averaged over the preceding three calendar years.)

Page 69: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-53 Air Emissions Management

Page 70: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-54 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.65. FUGITIVE EMISSIONS

AE.65.1.IL. Emissions of fugitive particulate matter from any process must meet specific restrictions (35 IAC 212.301) [Moved in structural reorganization of AE.5 October 1999].

Verify that the facility does not cause or allow the emission of fugitive particulate matter from any process, including any material handling or storage activity, that is visible by an observer looking generally toward the zenith at a point beyond the property line of the emission source.

AE.65.2.IL. Emissions of organic materials must meet specific restrictions (35 IAC 215.301 through 215.304, and 215.562) [Added May 1999; Moved in structural reorganization of AE.5 October 1999].

Verify that there are no discharges of more than 3.6 kg/h (8 lb/h) of organic material into the atmosphere from any emission unit.

(NOTE: If no odor nuisance exists, this limitation applies only to photochemically reactive material.)

(NOTE: Emissions of organic material in excess of 3.6 kg/h (8 lb/h) are allowable if such emissions are controlled by one of the following methods:

- flame, thermal or catalytic incineration so as either to reduce such emissions to 10 ppm equivalent methane (molecular weight 16) or less, or to convert 85 percent of the hydrocarbons to carbon dioxide and water, or

- a vapor recovery system which adsorbs and/or condenses at least 85 percent of the total uncontrolled organic material that would otherwise be emitted to the atmosphere, or

- any other air pollution control equipment approved by the Agency and approved by the USEPA as a SIP revision capable of reducing by 85 percent or more the uncontrolled organic material that would be otherwise emitted to the atmosphere.)

(NOTE: The preceding provisions do not apply to fuel combustion emission units, the application of paving asphalt and pavement marking paint from sunrise to sunset, or to any owner, operator, user or manufacturer of paint, varnish, lacquer, coatings or printing ink whose compliance program and project completion schedule, as required by 35 Ill. Adm. Code 201, provide for the reduction of organic material used in such process to 20 percent or less of total volume by 30 May 1977.)

Page 71: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-55 Air Emissions Management

Page 72: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-56 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

DRY CLEANING OPERATIONS AE.70. Petroleum Solvent

(NOTE: These provisions do not apply to petroleum solvent dry cleaning facilities whose emissions of volatile organic material do not exceed 91 megagrams (100 tons) per year in the absence of pollution control equipment or whose emissions of volatile organic material, as limited by the operating permit, will not exceed 91 megagrams (100 tons) per year in the absence of pollution control equipment.)

AE.70.1.IL. Emissions of volatile organic materials from petroleum solvent dry cleaners must be controlled (35 IAC 215.607).

Verify that the owner or operator of a petroleum solvent dry cleaning dryer either:

- of 3.5 kg of volatile organic material per 100 kilograms dry weight of articles dry cleaned, or

- installs and operates a solvent recovery dryer in a manner such that the dryer remains closed and the recovery phase continues until a final solvent flow rate of 50 mL per minute is attained.

Verify that the owner or operator of a petroleum solvent filtration system either:

- reduces the volatile organic material content in all filtration wastes to 1.0 kg or less per 100 kilograms dry weight of articles dry cleaned, before disposal, and exposure to the atmosphere, or

- installs and operates a cartridge filtration system, and drain the filter cartridges in their sealed housings for 8 h or more before their removal.

AE.70.2.IL. Petroleum sol-vent dry cleaners meet operational requirements (35 IAC 215.608).

Verify that, in order to minimize fugitive solvent emissions, the owner or operator of a petroleum solvent dry cleaning facility employs good housekeeping practices including the following:

- equipment containing solvent (washers, dryers, extractors and filters) remains closed at all times except during load transfer and maintenance

- lint filter and button trap covers remains closed except when solvent-laden material is being removed

- cans, buckets, barrels, and other containers of solvent or of solvent-laden material are covered except when in use

- solvent-laden material is exposed to the atmosphere only for the minimum time necessary for load transfer

- all cartridge filters are enclosed and operated in accordance with the procedures and specifications recommended by the manufacturer for the cartridge filter

- after installation, the cartridges are inspected, monitored and maintained in accordance with the manufacturer's recommendations

- vents on containers for new solvent and for solvent-containing waste are con-structed and maintained so as to minimize solvent vapor emissions.

Page 73: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-57 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.70.3.IL. Owners/opera-tors of petroleum solvent dry cleaning facilities meet inspect for and repair leaks (35 IAC 215.609).

Verify that the owner or operator of a petroleum solvent dry cleaning facility conducts the following visual inspections on a weekly basis:

- washers, dryers, solvent filters, settling tanks, vacuum stills, and containers and conveyors of petroleum solvent are inspected for visible leaks of solvent liquid

- pipes, hoses and fittings are inspected for active dripping or dampness - pumps and filters are inspected for leaks around seals and access covers - gaskets and seals are inspected for wear and defects - leaks of petroleum solvent liquid and vapors are repaired within 3 working

days of detection, unless necessary replacement parts are not on site.

Verify that, when necessary, repair parts are ordered within 3 working days of detection of the leak, and that the leak is repaired within 3 days of delivery of necessary parts.

AE.70.4.IL. Dry-cleaning facilities must be licensed (35 IAC 1500.20(a) and (b)(7)) [Added June 2000].

Verify that every active dry-cleaning facility obtains a license from the Council.

Verify that no person operates a dry-cleaning facility in this State without a license issued by the Council for that facility.

Verify that any dry-cleaning facility, which begins operation on or after 1 January 2000, obtains a license prior to operating the facility.

Page 74: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-58 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

DRY CLEANING OPERATIONS

AE.75. Perchloroethylene

AE.75.1.IL. The emission of volatile organic materials from perchloroethylene dry cleaners must be controlled (35 IAC 218.601 and 218.602, and 219.601 and 219.602) [Revised May 1999].

(NOTE: This checklist item applies only in the Chicago Area and Metro East Area (see definitions). The regulation that applied to the rest of the state of Illinois was repealed.)

Verify that the owner/operator of a dry cleaning facility which uses perchloroethylene:

- vents the entire dryer exhaust through a properly designed and functioning carbon adsorption system or equally effective control device

- emits no more than 100 ppmv of volatile organic material from the dryer control device before dilution, or achieve a 90 percent average reduction before dilution

- immediately repairs all components found to be leaking liquid volatile organic material

- cooks or treats all diatomaceous earth filters so that the residue contains 25 kg (55 lb) or less of volatile organic material per 100 kg (220 lb) of wet waste material

- reduces the volatile organic material from all solvent stills to 60 kg (132 lb) or less per 100 kg (220 lb) of wet waste material

- drains all filtration cartridges in the filter housing or other sealed container for at least 24 h before discarding the cartridges

- dries all drained filtration cartridges in equipment connected to an emission reduction system or in a manner that will eliminate emission of volatile organic material to the atmosphere.

AE.75.2.IL. Dry-cleaning facilities must be licensed (35 IAC 1500.20(a) and (b)(7)) [Added June 2000].

Verify that every active dry-cleaning facility obtains a license from the Council.

Verify that no person operates a dry-cleaning facility in this State without a license issued by the Council for that facility.

Verify that any dry-cleaning facility, which begins operation on or after 1 January 2000, obtains a license prior to operating the facility.

Page 75: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-59 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.80. ACID PRODUCTION UNITS

AE.80.1.IL. Emissions of sulfur dioxide (SO2) from sulfuric acid manufacturing plants must not exceed specific limits (35 IAC 214.381).

Verify that no person causes or allows the emission of sulfur dioxide into the atmosphere from any new sulfuric acid manufacturing plant to exceed 4.0 lb of sulfur dioxide per ton of acid produced (2.0 kg/Mg).

Verify that no person causes or allows the emission of sulfuric acid mist into the atmosphere from any process emission source to exceed 0.15 lb of acid mist per ton of acid manufactured (75 g/Mg).

Verify that no person causes or allows the emission of sulfur dioxide into the atmosphere from any sulfuric acid manufacturing process in the City of Chicago to exceed 500 ppm.

AE.80.2.IL. Emissions of nitrogen oxides (NOx) from nitric acid manufacturing plants must not exceed specific limits (35 IAC 217.381).

Verify that no person causes or allows the emission of NOx into the atmosphere from any new weak nitric acid manufacturing process to exceed the following standards and limitations:

- 1.5 kg of NOx (expressed as nitrogen dioxide) per metrictone of acid produced (100 percent acid basis) (3.0 lb/T)

- visible emissions in excess of 5 percent opacity - 0.05 kg of NOx (expressed as nitrogen dioxide) per metric tonne of acid pro-

duced (100 percent acid basis) from any acid storage tank vents (0.1 lb/T).

Verify that no person causes or allows the emission of NOx into the atmosphere from any existing weak nitric acid manufacturing process to exceed the following standards and limitations:

- 2.75 kg of NOx (expressed as nitrogen dioxide) per metric tonne of acid pro-duced (100 percent acid basis) (5.5 lb/T)

- visible emissions in excess of 5 percent opacity - 0.1 kg of NOx (expressed as nitrogen dioxide) per metric tonne of acid

produced (100 percent acid basis) from any acid storage tank vents (0.2 lb/T).

Verify that no person causes or allows the emission of NOx into the atmosphere

from any concentrated nitric acid manufacturing process to exceed the following standards and limitations:

- 1.5 kg of NOx (expressed as nitrogen dioxide) per metric tonne of acid produced (100 percent acid basis) (3.0 lb/T)

Page 76: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-60 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- 225 ppm of NOx (expressed as nitrogen dioxide) in any effluent gas stream emitted into the atmosphere

- visible emissions in excess of 5 percent opacity.

Verify that no person causes or allows the emission of NOx into the atmosphere from any nitric acid concentrating process to exceed the following limitations:

- 1.5 kg of NOx (expressed as nitrogen dioxide) per metric tonne of acid produced (100 percent acid basis) (3.0 lb/T)

- visible emissions in excess of 5 percent opacity.

Page 77: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-61 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.100. COATING OPERATIONS

AE.100.1.IL. Architectural coatings must meet content restrictions in the Chicago and St. Louis MMAs (35 IAC 215.561).

Verify that no person causes or allows the sale or use, in the Chicago or St. Louis major metropolitan areas, of any architectural coating containing more than 20 percent by volume of photochemically reactive material in containers having a capacity of more than 1 gal.

Motor Vehicle Refinishing (NOTE: The requirements of this subsection apply only in the Chicago and Metro East Areas (see definitions).)

AE.100.2.IL. Motor vehicle refinishing operations must meet volatile organic material (VOM) content limits (35 IAC 218.780, 218.782, 219.780, and 219.782) [Added May 1999].

Verify that motor vehicle refinishing operation do not coat motor vehicles, mobile equipment, or their parts and components, unless all coatings, except touch-up coatings, do not exceed the VOM content limitations as listed in Appendix 1-5.

Verify that all coating are used according to manufacturer's specifications.

(NOTE: If a coating requires the addition of a reducer, hardener, or other additive, in some combination, this addition must not cause the coating, as applied, to exceed the applicable VOM content limitation.)

Verify that specialty coatings represent no more than 5 percent, by volume, of all coatings applied at a source on a monthly basis.

(NOTE: As an alternative to complying with the VOM content limitations, the owner or operator of a motor vehicle refinishing operation may operate control equipment that reduces VOM emissions at the source by at least 90 percent.)

AE.100.3.IL. Motor vehicle refinishing operations must meet equipment and operating requirements (35 IAC 218.784 and 219.784) [Added May 1999].

(NOTE: These requirements do not apply to a source that uses less than 20 gal of coating per calendar year from all motor vehicle refinishing operations combined.)

Verify that motor vehicle refinishing operations coat motor vehicles, mobile equipment, or their parts and components using one of the following coating applicators:

- electrostatic spray equipment calibrated, operated and maintained in accordance with the manufacturer's specifications, or

- High Volume Low Pressure (HVLP) spray equipment calibrated, operated and maintained in accordance with the manufacturer's specifications.

Page 78: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-62 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that motor vehicle refinishing operations clean all coating applicators with a device that:

- recirculates solvent during the cleaning process - collects spent solvent so it is available for disposal or recycling - minimizes evaporation of solvents during cleaning, rinsing, draining, and

storage.

AE.100.4.IL. Surface preparation materials must meet VOM content limitations (35 IAC 218.786 and 219.786) [Added May 1999].

Verify that surface preparation materials never exceed the following VOM content limitations for the specified substrate:

Substrate Kg/l (lb/gal)

Plastic parts 0.79 (6.5)

Other substrates 0.17 (1.4)

AE.100.5.IL. Motor vehicle refinishing operations must comply with work practice requirements (35 IAC 218.787 and 219.787) [Added May 1999].

Verify that fresh and spent solvent, cloth or paper used to apply solvents for surface preparation or cleanup, waste paint, and sludge are stored in closed containers.

Verify that motor vehicle refinishing operations exempt from the equipment specifications in Section 218.784 (see AE.100.3.IL.) because it uses less than 20 gal of coating per year directs solvent used to clean coating applicator equipment and paint lines into a container for proper disposal or recycling.

AE.100.6.IL. Motor vehicle refinishing operations that use control devices must meet monitoring and record keeping requirements (35 IAC 218.789 and 219.789) [Added May 1999].

Verify that motor vehicle refinishing operations that comply with VOM emission limits by using control devices:

- install and operate equipment to continuously monitor each control - keep records of parameters for control devices as monitored - keep logs of operating time of the control device and monitoring equipment - keep logs of maintenance of the control device and monitoring equipment - maintain all records required for the most recent consecutive 3 yr period and

make all such records available to the Agency immediately upon request.

(NOTE: An owner or operator may monitor with an alternative method or monitor other parameters, if approved by the Agency and USEPA through federally

Page 79: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-63 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

enforceable permit conditions.)

AE.100.7.IL. Motor vehicle refinishing operations must meet reporting and record keeping requirements (35 IAC 218.790 and 219.790) [Added May 1999].

Verify that a motor vehicle refinishing operation maintains the following records for the most recent consecutive 3 yr, and makes them available to the Agency immediately upon request:

- the name and manufacturer of each coating and surface preparation product used at the source each month

- the volume of each category of coating purchased by the source each month - the coating mixing instructions, as stated on the container, in literature

supplied with the coating, or otherwise specified by the manufacturer, for each coating purchased by the source each month

- the VOM content, expressed as weight of VOM per volume of coating, minus water and any compounds that are specifically exempted from the definition of VOM, recorded on a monthly basis for:

- each coating as purchased, if the coating is not mixed with any additives prior to application on the substrate, or

- each coating after mixing according to manufacturer's instructions - the weighted average VOM content of the coating, for each

basecoat/clearcoat, and three or four stage coating system purchased by the source, recorded on a monthly basis

- the total monthly volume of all specialty coatings purchased and the percentage specialty coatings comprise in the aggregate of all coatings purchased by the source each month

- the volume of each category of surface preparation material, purchased by the source each month

- the VOM content, expressed as weight of VOM per volume of material, including water, of each surface preparation material purchased by the source, recorded on a monthly basis.

AE.100.8.IL. Motor vehicle refinishing operations must meet registration requirements (35 IAC 218.792 and 219.792) [Added May 1999].

Verify that motor vehicle refinishing operation register with the Agency and re-register no later than 45 days following the end of each calendar year.

Verify that the following information is included in this registration:

- the name and address of the source, and the name and telephone number of the person responsible for submitting the registration information

- a description of all coating operations of motor vehicles, mobile equipment, or their parts or components, and all associated surface preparation operations at the source

- a description of all coating applicators used at the source, if applicable - a description of all cleanup operations at the source - a description of all work practices at the source - if a source claims to be exempt from the equipment requirements because it

uses less than 20 gall of coating per year, the owner's or operator's

Page 80: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-64 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

certification that the annual usage is below this level - a written declaration stating whether the source is complying with this

Subpart by using coatings that comply or by control equipment - a description of any control devices used and the date(s) the device was

installed and became operational.

Verify that, at least 30 calendar days before changing the method of compliance, the owner or operator of a motor vehicle refinishing operation notifies the Agency and certifies that the source is in compliance with the applicable requirements for the new method of compliance.

Page 81: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-65 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

DEGREASING OPERATIONS AE.116. Cold Cleaning

(NOTE: These requirements apply to all cold cleaning degreasers, regardless of solvent used, whereas the Federal requirements only apply to degreasers that use one of six HAP solvents. These requirements do not apply to sources whose emissions of VOM do not exceed 6.8 kg (15 lb) in any one day, nor 1.4 kg (3 lb) in any one hour (35 IAC 215.181(a)).)

AE.116.1.IL. Cold cleaning degreasers must meet specific operating requirements (35 IAC 215.182(a)).

Verify that waste solvent is stored in covered containers only and not disposed of in a manner that more than 20 percent of the waste solvent (by weight) is allowed to evaporate into the atmosphere.

Verify that the cover of the degreaser is closed when parts are not being handled.

Verify that parts are drained until dripping ceases.

AE.116.2.IL. Cold cleaning degreasers must meet specific equipment requirements (35 IAC 215.182(b)).

Verify that the degreaser is equipped with a cover which is closed whenever parts are not being handled in the cleaner.

Verify that the cover is designed to be easily operated with one hand or with the mechanical assistance of springs, counter-weights, or a powered system, if one of the following conditions exists:

- the solvent vapor pressure is greater than 2 kPa (15 mm Hg or 0.3 psi) measured at 38 °C (100 °F)

- the solvent is agitated - the solvent is heated above ambient room temperature.

Verify that the degreaser is equipped with a facility for draining cleaned parts.

Verify that the drainage facility is constructed so that parts are enclosed under the cover while draining unless one of the following conditions exists:

- the solvent vapor pressure is less than 4.3 kPa (32 mm Hg or 0.6 psi) measured at 38 °C (100 °F)

- an internal drainage facility cannot be fitted into the cleaning system, in which case the drainage facility may be external.

Verify that the degreaser is equipped with one of the following control devices if

the vapor pressure of the solvent is greater than 4.3 kPa (32 mm Hg or 0.6 psi) measured at 38 °C (100 °F), or if the solvent is heated above 50 °C (120 °F) or its boiling point:

- a freeboard height of 7/10 of the inside width of the tank or 91 cm (36 in.), whichever is less

- water cover

Page 82: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-66 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- refrigerated chiller - carbon absorber - any other equipment or system of equivalent emission control as approved by

the Agency.

Verify that a permanent, conspicuous label summarizing the operating procedure is affixed to the degreaser.

Verify that, if a solvent spray is used, the degreaser is equipped with a solid fluid stream spray, rather than a fine, atomized or shower spray.

Cold Cleaners in the Chicago Area

(NOTE: The requirements in this subsection apply to cold cleaning degreasers in the Chicago area, which is comprised of Cook, DuPage, Kane, Lake, McHenry and Will Counties and Aux Sable Township and Goose Lake Township in Grundy County and Oswego Township in Kendall County.)

AE.116.3.IL. Cold cleaning degreasers in the Chicago area must meet additional requirements (35 IAC 218.182(c)(1)(B), (c)(2)(B), (d)(2), (e), (f), and (g)) [Added May 1998].

Verify that on and after 15 March 1999, no person operates a cold cleaning degreaser with a solvent vapor pressure which exceeds 2.0 mmHg (0.038 psi) measured at 20°C (68°F)

Verify that on and after 15 March 2001, no person operates a cold cleaning degreaser with a solvent vapor pressure which exceeds 1.0 mmHg (0.019 psi) measured at 20°C (68°F).

Verify that on and after 15 March 1999, all persons who operate a cold cleaning degreaser maintain records which include for each purchase:

- the name and address of the solvent supplier - the date of purchase - the type of solvent - the vapor pressure of the solvent measured in mmHg at 20°C (68°F).

Verify that these records are retained for three years and made available to the Agency upon request.

(NOTE: The cleaning of electronic components is exempt from these requirements.)

(NOTE: Any cold cleaning taking place in a Detrex cold batch degreaser Model #2D-CC-SPL Size 24-4-10, or substantial equivalent, including automated loading of parts, totally enclosed operation (excluding loading or unloading) and permitted by the Agency, is exempt from these requirements.)

Page 83: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-67 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Cold Cleaners in the Metro East Area

(NOTE: The requirements in this subsection apply to cold cleaning degreasers in the Metro East area, which is comprised of Madison, Monroe, and St. Clair Counties.)

AE.116.4.IL. Cold cleaning degreasers in the Chicago area must meet additional requirements (35 IAC 219.182(c)(1)(B), (c)(2)(B), (d)(2), (e), (f), and (g)) [Added May 1998].

Verify that on and after 15 March 1999, no person operates a cold cleaning degreaser with a solvent vapor pressure which exceeds 2.0 mmHg (0.038 psi) measured at 20°C (68°F)

Verify that on and after 15 March 2001, no person operates a cold cleaning degreaser with a solvent vapor pressure which exceeds 1.0 mmHg (0.019 psi) measured at 20°C (68°F).

Verify that on and after 15 March 1999, all persons who operate a cold cleaning degreaser maintain records which include for each purchase:

- the name and address of the solvent supplier - the date of purchase - the type of solvent - the vapor pressure of the solvent measured in mmHg at 20°C (68°F).

Verify that these records are retained for three years and made available to the Agency upon request.

(NOTE: The cleaning of electronic components is exempt from these requirements.)

(NOTE: Any cold cleaning taking place in a Detrex cold batch degreaser Model #2D-CC-SPL Size 24-4-10, or substantial equivalent, including automated loading of parts, totally enclosed operation (excluding loading or unloading) and permitted by the Agency, is exempt from these requirements.)

Page 84: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-68 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

DEGREASING OPERATIONS AE.117. Vapor Cleaning

(NOTE: These requirements apply to all cold cleaning degreasers, regardless of solvent used, whereas the Federal requirements only apply to degreasers that use one of six HAP solvents. These requirements do not apply to sources whose emissions of VOM do not exceed 6.8 kg (15 lb) in any one day, nor 1.4 kg (3 lb) in any one hour (35 IAC 215.181(a)).)

AE.117.1.IL. Open top vapor degreaser operators must meet specific requirements (35 IAC 215.183(a)).

Verify that the cover of the degreaser is closed when workloads are not being pro-cessed through the degreaser.

Verify that solvent carryout emissions are minimized by:

- racking parts to allow complete drainage - moving parts in and out of the degreaser at less than 3.3 m/min (11 ft/min) - holding the parts in the vapor zone until condensation ceases - tipping out any pools of solvent on the cleaned parts before removal from the

vapor zone - allowing parts to dry within the degreaser until visually dry.

Verify that porous or absorbent materials, such as cloth, leather, wood, or rope are not degreased.

Verify that less than half of the degreaser’s open top area is occupied with a workload.

Verify that the degreaser is not loaded to the point where the vapor level would drop more than 10 cm (4 in.) when the workload is removed from the vapor zone.

Verify that spraying is done below the vapor level only.

Verify that solvent leaks are repaired immediately.

Verify that waste solvent is stored in covered containers only and not disposed of in a manner that more than 20 percent of the waste solvent (by weight) is allowed to evaporate into the atmosphere.

Verify that water is not visually detectable in solvent exiting from the water separator.

Verify that exhaust ventilation exceeding 20 m3/min/m2 (65 ft3/min/ft2) of degreaser open area is not used.

AE.117.2.IL. Open top vapor degreasers must meet specific

Verify that the degreaser is equipped with a cover designed to open and close easily without disturbing the vapor zone.

Page 85: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-69 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

equipment requirements (35 IAC 215.183(b)).

easily without disturbing the vapor zone.

Verify that the degreaser is equipped with the following switches:

- a device which shuts off the sump heat source if the amount of condenser coolant is not sufficient to maintain the designed vapor level

- a device which shuts off the spray pump if the vapor level drops more than 10 cm (4 in.) below the bottom condenser coil

- a device which shuts off the sump heat source when the vapor level exceeds the design level.

Verify that a permanent conspicuous label summarizing the operating procedure is

affixed to the degreaser.

Verify that the degreaser is equipped with one of the following devices:

- a freeboard height of 3/4 of the inside width of the degreaser tank or 91 cm (36 in.), whichever is less

- a powered or mechanically assisted cover, if the degreaser opening is greater than 1 m2 (10.8 ft2)

- refrigerated chiller - enclosed design - carbon adsorption system - any other equipment or system of equivalent emission control as approved by

the Agency.

Conveyorized Degreasers

AE.117.3.IL. Conveyorized degreasers must meet specific operating requirements (35 IAC 215.184(a)).

Verify that no person operates a conveyorized degreaser unless:

Verify that exhaust ventilation exceeding 20 m3/min/m2 (65 ft3/min/ft2) of area of loading and unloading opening is not used, unless necessary to meet the requirements of the Occupational Safety and Health Act.

Verify that solvent carry-out emissions are minimized by:

- racking parts for best drainage - maintaining the vertical conveyor speed at less than 3.3 m/min (11 ft/min).

Verify that waste solvent is stored in covered containers only and not disposed of in such a manner that more than 20 percent of the waste solvent (by weight) is allowed to evaporate into the atmosphere.

Verify that solvent leaks are repaired immediately.

Page 86: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-70 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that water is not visually detectable in solvent exiting from the water separator.

Verify that downtime covers are placed over entrances and exits of conveyorized degreasers immediately after the conveyors and exhausts are shut down and not removed until just before start-up.

AE.117.4.IL. Conveyorized degreasers must meet specific equipment requirements (35 IAC 215.184(b)).

Verify that the degreaser is equipped with a drying tunnel, rotating (tumbling) basket or other equipment sufficient to prevent cleaned parts from carrying out solvent liquid or vapor.

Verify that the degreaser is equipped with the following switches:

- a device which shuts off the sump heat source if the amount of condenser coolant is not sufficient to maintain the designed vapor level

- a device which shuts off the spray pump or the conveyor if the vapor level drops more than 10 cm (4 in.) below the bottom condenser coil

- a device which shuts off the sump heat source when the vapor level exceeds the design level.

Verify that the degreaser is equipped with openings for entrances and exits that sil-

houette workloads so that the average clearance between the parts and the edge of the degreaser opening is less than 10 cm (4 in.) or less than 10 percent of the width of the opening.

Verify that the degreaser is equipped with downtime covers for closing off entrances and exits when the degreaser is shut down.

Verify that the degreaser is equipped with one of the following control devices, if the air/vapor interface is larger than 2.0 m2 (21.6 ft2):

- a carbon adsorption system with ventilation greater than or equal to 15 m3/min/ m2 (50 ft3/min/ft2) of air/vapor area when downtime covers are open, and exhausting less than 25 ppm of solvent by volume averaged over a complete adsorption cycle; or

- any other equipment or system of equivalent emission control as approved by the Agency (such equipment or system may include a refrigerated chiller).

Page 87: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-71 Air Emissions Management

Page 88: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-72 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.130. OPEN BURNING

AE.130.1.IL. Open burning is restricted (35 IAC 237.102, 237.120, and 237.201).

Verify that no person causes or allows open burning, except as exempted below.

Verify that no person causes or allows the burning of any refuse in any chamber or apparatus, unless such chamber or apparatus is designed for the purpose of disposing of the class of refuse being burned.

(NOTE: Permits may be obtained for certain other types of burning.)

(NOTE: The following types of open burning are allowed: - the open burning of landscape waste, if the following conditions are met:

- on the premises on which the waste is generated - when atmosphere conditions will readily dissipate contaminants - if the burning does not create a visibility hazard on roadways, railroad

tracks, or air fields - in any areas of the state other than the following:

- municipalities having a population in excess of 2500 according to the latest Federal census

- municipalities of any size which adjoin a municipality having a population in excess of 2500

all municipalities wholly within 40 air miles (64.5 km) of Meigs Field, Chicago, IL

- all municipalities wholly within 20 air miles (32.3 km) of McKinley Bridge connecting St. Louis, MO, and Venice, IL

- rural areas 305 m (1000 ft) or less from a municipality in which open burning of landscape waste is prohibited

- the open burning of agricultural waste, but only: - on the premises on which the waste is generated

- in areas other than restricted areas - when atmosphere conditions will readily dissipate contaminants - if the burning does not create a visibility hazard on roadways, railroad

tracks, or air fields - more than 305 m (1000 ft) from residential or other populated areas - when it can be affirmatively demonstrated that no economically

reasonable alternative method of disposal is available - the open burning of domicile waste, but only:

- on the premises on which the waste is generated - in areas other than restricted areas - when atmosphere conditions will readily dissipate contaminants - if the burning does not create a visibility hazard on roadways, railroad

tracks, or air fields

Page 89: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-73 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- the burning of fuels for legitimate campfire, recreational and cooking purposes, or in domestic fireplaces, provided that no garbage is burned in such cases

- the burning of waste gases, provided that all flares are equipped with smokeless tips or comparable devices to reduce pollution

- small open flames for heating tar, for welding, acetylene torches, highway safety flares, and the like.)

Page 90: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-74 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.135. VEHICLE EMISSIONS

AE.135.1.IL. Facilities that operate motor vehicles fueled with liquid petroleum gas are required to meet specific requirements (35 IAC 240.123).

Verify that motor vehicles which are fueled solely with liquid petroleum gas have excess air injection systems inoperative, where the systems are installed by the vehicle manufacturer.

Verify that motor vehicles which operate on liquid petroleum gas or gasoline fuel alternately, in dual fuel systems, meet the following requirements:

- excess air injection systems are inoperative when operating on liquid petroleum gas, where excess air injection systems are installed by the vehicle manufacturer

- excess air injection systems are operational when operating on gasoline, where excess air injection systems are installed by the vehicle manufacturer

- the intake manifold heat riser system to the carburetor is in operation at all times when the motor vehicle is operating.

Page 91: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-75 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.145. ASPHALT PAVING MATERIALS/ OPERATIONS

AE.145.1.IL. The use and application of cutback asphalt is restricted (35 IAC 215.563(a))

Verify that no person causes or allows the use or application of cutback asphalt for paving, resurfacing, reconditioning, repairing, or otherwise maintaining a roadway unless one of the following conditions is met:

- the use or application of the cutback asphalt commences on or after 1 October of any year and such use or application is completed by 30 April of the following year

- the cutback asphalt is a long-life stockpile material which remains in stock after 30 April of each year and is used until depleted for patching potholes and for other similar repair work

- the cutback asphalt is to be used solely as an asphalt prime coat.

Page 92: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-76 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

AE.160. COUNTY/CITY-SPECIFIC REQUIREMENTS

Sources Located In Chicago, St. Louis (Illinois), or Peoria MMAs

AE.160.1.IL. Facilities located in the Chicago, St. Louis, and Peoria metropolitan areas are required to restrict the emission of sulfur dioxide from any existing fuel combustion emission source (35 IAC 214.141(a)).

Determine whether the facility is located in the Chicago, St. Louis, or Peoria MMAs.

Verify that the facility does not cause or allow the emission of sulfur dioxide into the atmosphere in any one hour period from any existing fuel combustion source, burning solid fuel exclusively, to exceed 1.8 lb (774 ng/J) of sulfur dioxide per MBtu of actual heat input.

Small Sources Located Outside Metropolitan Areas

AE.160.2.IL. Facilities located outside metropolitan areas are required to restrict the emission of sulfur dioxide from any existing fuel combustion emission source (35 IAC 214.142, and 214.186).

(NOTE: This applies to existing fuel combustion sources with actual heat input less than, or equal to, 73.2 MW (250 MBtu/h) located outside the Chicago, St. Louis, or Peoria MMAs.)

Verify that the facility does not cause or allow the emission of sulfur dioxide into the atmosphere in any one hour period from any existing fuel combustion source with actual heat input less than, or equal to, 73.2 MW (250 MBtu/h), burning solid fuel exclusively, to exceed either of the following:

- 10.5 kg of sulfur dioxide per MW-h (6.8 lb/MBtu) of actual heat input, provided that a new operating permit has been obtained from the Agency

- the emission limit determined by the formula: E = A X[B] Y[C] where:

E = Total allowable emission of sulfur dioxide into the atmosphere in any one-hour period from all fuel combustion emission sources owned or operated by such person and located within a 1.6 km (1 mile) radius from the

Page 93: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-77 Air Emissions Management

COMPLIANCE CATEGORY: AIR EMISSIONS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

center point of any such emission source. X = Average actual stack Y = Effective height of effluent release as determined by method outlined in

Appendix C.

Large Sources Located In Major Metropolitan Areas

AE.160.3.IL. Existing fuel combustion emission sources located within metropolitan areas are required to restrict the emission of nitrogen oxides (35 IAC 217.141).

(NOTE: This does not apply to existing fuel combustion sources which are either cyclone fired boilers burning solid or liquid fuel, or horizontally opposed fired boilers burning solid fuel.)

Verify that the facility does not cause or allow the emission of nitrogen oxides into the atmosphere in any one hour period from any existing fuel combustion source with an actual heat input equal to or greater than 73.2 MW (250 MBtu/h), located in the Chicago or St. Louis MMAs, to exceed the following:

- 0.46 kg/MW-h (0.3 lb/MBtu) of actual heat input, for gaseous and/or liquid fossil fuel firing

- 1.39 kg/MW-h (0.9 lb/MBtu) of actual heat input, for solid fossil fuel firing.

(NOTE: For fuel combustion emission sources burning simultaneously any combination of solid, liquid, and gaseous fossil fuels, an allowable emission rate is determined by the following equation: E = (AG + BL + CS) Q where:

E = Allowable nitrogen oxides emissions Q = Actual heat input G = Percent of actual heat input derived from gaseous fossil fuel L = Percent of actual heat input derived from liquid fossil fuel S = Percent of actual heat input derived from solid fossil fuel G + L + S = 100.0.)

Page 94: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-78 Air Emissions Management

Appendix 1-1

Exempt Sources (Source: 35 IAC 201.146) [Revised May 1999]

Section 201.146 Exemptions from State Permit Requirements Construction or operating permits, pursuant to Sections 201.142, 201.143 and 201.144 of this Part, are not required for the classes of equipment and activities listed below in this Section. The permitting exemptions in this Section do not relieve the owner or operator of any source from any obligation to comply with any other applicable requirements, including the obligation to obtain a permit pursuant to Sections 9.1(d) and 39.5 of the Act, Sections 165, 173 and 502 of the Clean Air Act or any other applicable permit or registration requirements.

a) Air contaminant detectors or recorders, combustion controllers or combustion shutoffs; b) Air conditioning or ventilating equipment not designed to remove air contaminants generated by or

released from associated equipment; c) Each fuel burning emission unit for indirect systems and for heating and reheating furnace systems used

exclusively for residential or commercial establishments using gas and/or fuel oil exclusively with a design heat input capacity of less than 14.6 MW (50 MBtu/h), except that a permit shall be required for any such emission unit with a design heat input capacity of at least 10 MBtu/h that was constructed, reconstructed or modified after June 9, 1989 and that is subject to 40 CFR 60, Subpart D;

d) Each fuel burning emission unit other than those listed in subsection (c) of this Section for direct systems used for comfort heating purposes and indirect heating systems with a design heat input capacity of less than 2930 kW (10 MBtu/h);

e) Internal combustion engines or boilers (including the fuel system) of motor vehicles, locomotives, air craft, watercraft, lift trucks and other vehicles powered by nonroad engines;

f) Bench scale laboratory equipment and laboratory equipment used exclusively for chemical or physical analysis, including associated laboratory fume hoods, vacuum producing devices and control devices installed primarily to address potential accidental releases;

g) Coating operations located at a source using not in excess of 18,925 l (5,000 gal) of coating (including thinner) per year;

h) Any emission unit acquired exclusively for domestic use, except that a permit shall be required for any incinerator and for any fuel combustion emission unit using solid fuel with a design heat input capacity of 14.6 MW (50 MBtu/h) or more;

i) Any stationary internal combustion engine with a rated power output of less than 1118 kW (1500 horsepower), except that a permit shall be required for any stationary gas turbine engine with a rated heat input at peak load of 10.7 gigajoules/h (10 MBtu/h) or more that is constructed, reconstructed or modified after October 3, 1977 and that is subject to requirements of 40 CFR 60, Subpart GG;

j) Rest room facilities and associated cleanup operations, and stacks or vents used to prevent the escape of sewer gases through plumbing traps;

k) Safety devices designed to protect life and limb, provided that a permit is not otherwise required for the emission unit with which the safety device is associated;

l) Storage tanks for liquids for retail dispensing except for storage tanks that are subject to the requirements of 35 Ill. Adm. Code 215.583(a)(2), 218.583(a)(2) or 219.583(a)(2);

m) Printing operations with aggregate organic solvent usage that never exceeds 2,839 1 (750 gal) per year from all printing lines at the source, including organic solvent from inks, diluents, fountain solutions and cleaning materials;

n) Storage tanks of:

1) Organic liquids with a capacity of less than 37,850 1 (10,000 gal), provided the storage tank is not used to store any material listed as a hazardous air pollutant pursuant to Section 112(b) of the Clean Air Act, and provided the storage tank is not subject to the requirements of 35 Ill. Adm. Code 215.583(a)(2), 218.583(a)(2) or 219.583(a)(2);

Page 95: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-79 Air Emissions Management

2) Any size containing exclusively soaps, detergents, surfactants, waxes, glycerin, vegetable oil greases, animal fats, sweetener, corn syrup, aqueous salt solutions or aqueous caustic solutions, provided an organic solvent has not been mixed with such materials; or

3) Any size containing virgin or re-refined distillate oil, hydrocarbon condensate from natural gas pipeline or storage systems, lubricating oil or residual fuel oils.

o) Threaded pipe connections, vessel manways, flanges, valves, pump seals, pressure relief valves, pressure relief devices and pumps;

p) Sampling connections used exclusively to withdraw materials for testing and analyses; q) All storage tanks of Illinois crude oil with capacity of less than 151,400 l (40,000 gal) located on oil field

sites; r) All organic material-water single or multiple compartment effluent water separator facilities for Illinois

crude oil of vapor pressure of less than 34.5 kPa absolute (5 psia); s) Grain-handling operations, exclusive of grain-drying operations, with an annual grain through-put not

exceeding 300,000 bushels; t) Grain-drying operations with a total grain-drying capacity not exceeding 750 bushels per hour for 5%

moisture extraction at manufacturer's rated capacity, using the American Society of Agricultural Engineers Standard 248.2, Section 9, Basis for Stating Drying Capacity of Batch and Continuous-Flow Grain Dryers;

u) Portable grain-handling equipment and one-turn storage space; v) Cold cleaning degreasers that are not in-line cleaning machines, where the vapor pressure of the solvents

used never exceeds 2 kPa (15 mmHg or 0.3 psi) measured at 38°C (100°F) or 0.7 kpa (5 mmHg or 0.1 psi) at 20°C (68°F);

w) Coin-operated dry cleaning operations; x) Dry cleaning operations at a source that consume less than 30 gallons per month of perchloroethylene; y) Brazing, soldering, wave soldering or welding equipment, including associated ventilation hoods; z) Cafeterias, kitchens, and other similar facilities, including smokehouses, used for preparing food or

beverages, but not including facilities used in the manufacturing and wholesale distribution of food, beverages, food or beverage products, or food or beverage components;

aa) Equipment for carving, cutting, routing, turning, drilling, machining, sawing, surface grinding, sanding, planing, buffing, sand blast cleaning, shot blasting, shot peening, or polishing ceramic artwork, leather, metals (other than beryllium), plastics, concrete, rubber, paper stock, wood or wood products, where such equipment is either:

1) Used for maintenance activity; 2) Manually operated; 3) Exhausted inside a building; or 4) Vented externally with emissions controlled by an appropriately operated cyclonic inertial separator

(cyclone), filter, electro-static precipitor or a scrubber. bb) Feed mills that produce no more than 10,000 tons of feed per calendar year, provided that a permit is not

otherwise required for the source pursuant to Section 201.142, 201.143 or 201.144; cc) Extruders used for the extrusion of metals, minerals, plastics, rubber or wood, excluding:

1) Extruders used in the manufacture of polymers; 2) Extruders using foaming agents or release agents that contain volatile organic materials or Class I

or II substances subject to the requirements of Title VI of the Clean Air Act; and 3) Extruders processing scrap material that was produced using foaming agents containing volatile

organic materials or Class I or II substances subject to the requirements of Title VI of the Clean Air Act.

dd) Furnaces used for melting metals, other than beryllium, with a brim full capacity of less than 450 cubic

inches by volume; ee) Equipment used for the melting or application of less than 22,767 kg/yr (50,000 lb/yr) of wax to which

no organic solvent has been added; ff) Equipment used for filling drums, pails or other packaging containers, excluding aerosol cans, with soaps,

detergents, surfactants, lubricating oils, waxes, vegetable oils, greases, animal fats, glycerin, sweeteners,

Page 96: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-80 Air Emissions Management

corn syrup, aqueous salt solutions or aqueous caustic solutions, provided an organic solvent has not been mixed with such materials;

gg) Loading and unloading systems for railcars, tank trucks, or watercraft that handle only the following liquid materials: soaps, detergents, surfactant, lubricating oils, waxes, glycerin, vegetable oils, greases, animal fats, sweetener, corn syrup, aqueous salt solutions or aqueous caustic solutions, provided an organic solvent has not been mixed with such materials;

hh) Equipment used for the mixing and blending of materials at ambient temperatures to make water based adhesives, provided each material mixed or blended contains less than 5% organic solvent by weight;

ii) Die casting machines where a metal or plastic is formed under pressure in a die located at a source with a throughput of less than 2,000,000 lb of metal or plastic per year, in the aggregate, from all die casting machines;

jj) Air pollution control devices used exclusively with other equipment that is exempt from permitting, as provided in this Section;

kk) An emission unit for which a registration system designed to identify sources and emission units subject to emission control requirements is in place, such as the registration system found at 35 Ill. Adm. Code 218.586 (Gasoline Dispensing Operations -- Motor Vehicle Fueling Operations) and 35 Ill. Adm. Code 218, Subpart HH (Motor Vehicle Refinishing);

ll) Photographic process equipment by which an image is reproduced upon material sensitized to radiant energy;

mm) Equipment used for hydraulic or hydrostatic testing; nn) General vehicle maintenance and servicing activities conducted at a source, motor vehicle repair shops,

and motor vehicle body shops, but not including: 1) Gasoline fuel handling; and 2) Motor vehicle refinishing.

oo) Equipment using water, water and soap or detergent, or a suspension of abrasives in water for purposes of cleaning or finishing, provided no organic solvent has been added to the water;

pp) Administrative activities including, but not limited to, paper shredding, coping, photographic activities and blueprinting machines. This does not include incinerators;

qq) Laundry dryers, extractors, and tumblers processing that have been cleaned with water solutions of bleach or detergents that are:

1) Located at a source and process clothing, bedding and other fabric items used at the source, provided that any organic solvent present in such items before processing that is retained from cleanup operations shall be addressed as part of the VOM emissions from use of cleaning materials;

2) Located at a commercial laundry; or 3) Coin operated.

rr) Housekeeping activities for cleaning purposes, including collecting spilled and accumulated materials, including operation of fixed vacuum cleaning systems specifically for such purposes, but not including use of cleaning materials that contain organic solvent;

ss) Refrigeration systems, including storage tanks used in refrigeration systems, but excluding any combustion equipment associated with such systems;

tt) Activities associated with the construction, on-site repair, maintenance or dismantling of buildings, utility lines, pipelines, wells, excavations, earthworks and other structures that do not constitute emission units;

uu) Piping and storage systems for natural gas, propane and liquefied petroleum gas; vv) Water treatment or storage systems, as follows:

1) Systems for potable water or boiler feedwater; and 2) Systems, including cooling towers, for process water, provided that such water has not been in direct

or indirect contact with process streams that contain volatile organic material or materials listed as hazardous air pollutants pursuant to Section 112(b) of the Clean Air Act.

ww) Lawn care, landscape maintenance and grounds keeping activities; xx) Containers, reservoirs or tanks used exclusively in dipping operations to coat objects with oils, waxes or

greases, provided no organic solvent has been mixed with such materials; yy) Use of consumer products, including hazardous substances as that term is defined in the Federal

Hazardous Substances Act (15 U.S.C. 1261 et seq.), where the product is used at a source in the same manner as normal consumer use;

zz) Activities directly used in the diagnosis and treatment of disease, injury or other medical condition;

Page 97: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-81 Air Emissions Management

aaa) Activities associated with the construction, repair or maintenance of roads or other paved or open areas, including operation of street sweepers, vacuum trucks, spray trucks and other vehicles related to the control of fugitive emissions of such roads or other areas;

bbb) Storage and handling of drums or other transportable containers, where the containers are sealed during storage and handling;

ccc) Activities at a source associated with the maintenance, repair or dismantling of an emission unit or other equipment installed at the source, not including the shutdown of the unit or equipment, including preparation for maintenance, repair or dismantling, and preparation for subsequent startup, including preparation or a shutdown vessel for entry, replacement of insulation, welding and cutting, and steam purging of a vessel prior to startup;

ddd) Equipment used for corona arc discharge surface treatment of plastic with a power rating of 5 kW or less or equipped with an ozone destruction device;

eee) Equipment used to seal or cut plastic bags for commercial, industrial or domestic use; and fff) Each direct-fired gas dryer used for a washing, cleaning, coating or printing line, excluding:

1) Dryers with a rated heat input capacity of 2930 kW (10 MBtu/h) or more; and 2) Dryers for which emissions other than those attributable to combustion of fuel in the dryer, including

emissions attributable to use or application of cleaning agents, washing materials, coatings or inks or other process materials that contain volatile organic material are not addressed as part of the permitting of such line, if a permit is otherwise required for the line.

ggg) Municipal solid waste landfills with a maximum total design capacity of less than 2.5 million Mg or 2.5 million m3 that are not required to install a gas collection and control system pursuant to 35 Ill. Adm. Code 220 or 800 through 849 or Section 9.1 of the Act.

Page 98: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-82 Air Emissions Management

Appendix 1-2

Limits for New Process Emission Sources (Source: 35 IAC 212.321(c))

Metric English P

Mg/h E

kg/h P

English ton/h E

lb/h 0.05 0.1 0.2 0.3 0.4 0.5 0.7 0.9 1.8 2.7 3.6 4.5 9.0 13.0 18.0 23.0 27.0 32.0 36.0 41.0 45.0 90.0 140.0 180.0 230.0 270.0 320.0 360.0 408.0 454.0

0.25 0.29 0.42 0.64 0.74 0.84 1.00 1.15 1.66 2.1 2.4 2.7 3.9 4.8 5.7 6.5 7.1 7.7 8.2 8.8 9.3 13.4 17.0 19.4 22.0 24.0 26.0 28.0 30.1 30.4

0.05 0.10 0.20 0.30 0.40 0.50 0.75 1.00 2.00 3.00 4.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00 100.00 150.00 200.00 250.00 300.00 350.00 400.00 450.00 500.00

0.55 0.77 1.10 1.35 1.58 1.75 2.40 2.60 3.70 4.60 5.35 6.00 8.70 10.80 12.50 14.00 15.60 17.00 18.20 19.20 20.50 29.50 37.00 43.00 48.50 53.00 58.00 62.00 66.00 67.00

where: P = Process weight in metric or English tons per hour E = Allowable emission rate in kg or lb per hour.

Page 99: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-83 Air Emissions Management

Page 100: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-84 Air Emissions Management

Appendix 1 - 3

Limits for Existing Process Emission Sources (Source: 35 IAC 212.322(c))

Metric English

P Mg/h

E kg/h

P English ton/h

E lb/h

0.05 0.1 0.2 0.3 0.4 0.5 0.7 0.9 1.8 2.7 3.6 4.5 9.0 13.0 18.0 23.0 27.2 32.0 36.0 41.0 45.0 90.0 140.0 180.0 230.0 270.0 320.0 360.0 408.0 454.0

0.27 0.42 0.68 0.89 1.07 1.25 1.56 1.85 2.9 3.9 4.7 5.4 8.7 11.1 13.8 16.2 18.15 18.8 19.3 19.8 20.2 23.2 25.3 26.5 27.7 28.5 29.4 30.0 30.6 31.3

0.05 0.10 0.20 0.30 0.40 0.50 0.75 1.00 2.00 3.00 4.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00 100.00 150.00 200.00 250.00 300.00 350.00 400.00 450.00 500.00

0.55 0.87 1.40 1.83 2.22 2.58 3.38 4.10 6.52 8.56 10.40 12.00 19.20 25.20 30.50 35.40 40.00 41.30 42.50 43.60 44.60 51.20 55.40 58.60 61.00 63.10 64.90 66.20 67.70 69.00

where: P = Process weight in metric or English tons per hour E = Allowable emission rate in kilograms or lb per hour.

Page 101: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-85 Air Emissions Management

Page 102: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-86 Air Emissions Management

Appendix 1 - 4

Emission Limits for Existing Sources Using Solid Fuel Exclusively

Located Outside the Chicago Area (Source: 35 IAC 212.202)

METRIC UNITS

H (Range) Megawatts

S Kilograms per megawatt

Less than or equal to 2.93

1.55

Greater than 2.93, but smaller than 73.2

3.33H-0.715

Greater than or equal to 73.2 0.155

ENGLISH UNITS H (Range)

MBtu per hour S

Pounds per MBtu Less than or equal to 10 1.0 Greater than 10, but smaller than 250

5.18H-0.715

Greater than or equal to 250 0.101 where: S = Allowable emission standard in lb/MBtu/h or kg/MW of actual heat input H = Actual heat input in MBtu/h or MW.

Page 103: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-87 Air Emissions Management

Appendix 1 - 5

Emission Limits Motor Vehicle Refinishing (Source: 35 IAC 218.780 and 219.780) [Added May 1999]

kg/l (lb/gal) Pretreatment wash primer 0.78 (6.5) Precoat 0.66 (5.5) Primer/primer surfacer coating 0.58 (4.8) Primer sealer 0.55 (4.6) Topcoat system or basecoat/clearcoat 0.60 (5.0) Three or four stage topcoat system 0.63 (5.2) Specialty coatings 0.84 (7.0) Anti-glare/safety coating 0.84 (7.0)

The following equations shall be used to calculate the VOM content of topcoat systems: 1) The VOM content of basecoat/clearcoat systems shall be calculated in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), according to the following equation: VOM T(bc/cc) = (VOM(bc) + 2 VOM(cc))/3 Where: VOM T(bc/cc) = The weighted average of the VOM content, applied, in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), in the basecoat (bc) and clearcoat (cc) system; VOM(bc) = The VOM content, as applied, in units of kg/VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), of any given basecoat; and VOM(cc) = The VOM content, as applied, in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), of any given clearcoat. 2) The VOM content for a three stage coating system shall be calculated in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), according to the following formula: VOM T(ms) = (VOM(bc) + VOM(mc) + 2 VOM(cc))/4 Where: VOM T(ms) = The weighted average of the VOM content, as applied, in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), in the basecoat, midcoat and clearcoat system; VOM (bc) = The VOM content, as applied, in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), any given basecoat; VOM(mc) = The VOM content, as applied, in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), of any given midcoat; and VOM(cc) = The VOM content, as applied, in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically-exempted from the definition of VOM), of any given clearcoat.

Page 104: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-88 Air Emissions Management

3) The VOM content for a four stage coating system shall be calculated in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), according to the following formula: VOM T(ms) = (VOM(bc) + VOM(mc1) + VOM(mc2) + 2 VOM(cc)/5 Where: VOM T(ms) = The weighted average of the VOM content, as applied, in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), in the basecoat, midcoats and clearcoat system; VOM(bc) = The VOM content, as applied, in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), of any given basecoat; VOM(mc1) = The VOM content, as applied, in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), of the first midcoat; VOM(mc2) = The VOM content, as applied, in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), of the second midcoat; and VOM(cc) = The VOM content, as applied, in units of kg VOM/l (lbs VOM/gal) of coating, (minus water and any compounds which are specifically exempted from the definition of VOM), of any given clearcoat.

Page 105: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-89 Air Emissions Management

Appendix 1-6

Emission Limits for Small, Medium, and Large HMIWIs

(35 IAC Section 229.125 )[Added June 2000]

Pollutant Units (7% oxygen dry basis) HMIWI Emission Limits

Small Medium Large PM Milligrams per dry standard cubic meter

(grains per dry standard cubic foot (dscf))

115 (0.05)

69 (0.03)

34 (0.015)

CO

Parts per million by volume (ppmv) 40 40 40

Dioxins/ furans

Nanograms per dscm or nanograms per dry standard cubic meter total dioxins/furans TEQ (grains per billion dscf).

125 (55) or 2.3 (1.0)

125 (55) or 2.3 (1.0)

125 (55) or 2.3 (1.0)

HCl ppmv or percent reduction

100 or 93% 100 or 93% 100 or 93%

SO(2) ppmv

55 55 55

NO(x) ppmv

250 250 250

Pb Milligrams per dry standard cubic meter (grains per thousand dry standard cubic feet) or percent reduction

1.2 (0.52) or 70%

1.2 (0.52) or 70%

1.2 (0.52) or 70%

Cd Milligrams per dry standard cubic meter (grains per thousand per dry standard cubic feet) or percent reduction

0.16 (0.07) or 65%

0.16 (0.07) or 65%

0.16 (0.07) or 65%

Hg Milligrams per dry standard cubic meter (grains per thousand dry standard cubic feet) or percent reduction.

0.55 (0.24) or 85%

0.55 (0.24) or 85%

0.55 (0.24) or 85%

Opacity--------------No owner or operator or a small, medium, or large HMIWI shall cause or allow any emissions that cause greater than 10 percent opacity, as measured on a 6 minute block average, according to Method 9, 40 CFR 60, Appendix A, incorporated by reference at Section 229.104(d) of this Part, from any stack used by an HMIWI.

Page 106: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-90 Air Emissions Management

Appendix 1-7

Operating Parameters for HMIWIs To Be Monitored and Minimum Measurement and Recording Frequencies

(Source: 35 IAC 229 Appendix B ) [Added June 2000]

Minimum Frequency Control System

Operating parameters

Data measure-

ment

Data recording

Dry scrubber followed by fabric

filter

Wet scrubber

Dry scrubber followed by

fabric filter and wet scrubber

Maximum charge rate Continuous Once/ hour x x x

Maximum fabric filter inlet temperature Continuous Once/minute x x

Maximum flue gas temperature Continuous Once/minute x x

Minimum secondary chamber temp. Continuous Once/minute x x x

Minimum dioxin/furan sorbent flow rate

Hourly Once/minute x x

Minimum HCl sorbent flow rate Hourly Once/minute x x

Minimum mercury (Hg) sorbent flow rate

Hourly Once/minute x x

Minimum pressure drop across the wet scrubber or minimum horsepower or amperage to wet scrubber

Hourly Once/minute x x

Minimum scrubber liquor flow rate Continuous Once/minute x x

Minimum scrubber liquor pH Continuous Once/minute x x

Page 107: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

1-91 Air Emissions Management

Appendix 1-8 Emission Limits for Rural HMIWIs

(Source: 35 IAC 228.126) [Added June 2000]

Pollutant

Units (7% oxygen, dry basos)

Emission Limits

PM mg per dscm (grains per dscf) 197 (0.086) CO ppmv 40 Dioxins/Furans |Nanograms per dscm, total dioxins/furans (grains

per billion dscf), or nanograms per dscm TEQ (grains per billion dscf )

800 (350) or 15 (6.6)

HCl ppmv 3100 SO (2) ppmv 55 NO (x) ppmv 250 Pb Mg per dscm (grains per thousand dscf) 10 (4.4) Cd Mg per dscm (grains per thousand dscf) 4 (1.7) Hg Mg per dscm (grains per thousand dscf) 7.5 (3.3)

Opacity------------No owner or operator of a rural HMIWI shall cause or allow any emissions that cause greater than 10 percent opacity, as measured on a 6 minute block average, according to Method 9, 40 CFR 60, Appendix A, incorporated by reference at Section 229.104(d) of this Part, from any stack used by an HMIWI.

Page 108: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

2-1 Cultural Resources Management

SECTION 2

CULTURAL RESOURCES MANAGEMENT

Illinois Supplement, June 2000 This section covers the Illinois requirements for Cultural Resources Management and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Definitions

• Agency - Illinois Historic Preservation Agency (Title 17, Illinois Administrative Code, Section 4170.110 (17 IAC 4170.110)).

• Director - Director of Historic Preservation (17 IAC 4170.110). • Disturb - includes excavating, removing, exposing, defacing, mutilating, destroying, molesting, or desecrating in

any way human skeletal remains, unregistered graves, and markers (17 IAC 4170.110). • Grave Markers - any tombs, monuments, stones, ornaments, mounds, or other item of human manufacture that

are associated with an unregistered grave (17 IAC 4170.110). • Human Skeletal Remains or Human Remains - any part of the body of a deceased person in any stage of

decomposition in a context indicating substantial evidence for an intentional or unintentional burial; or, a disarticulated or articulated skeleton (17 IAC 4170.110).

• Unmarked Burial Site - any interment of human skeletal remains for which there exists no grave marker or any

other historical documentation and that was not previously known or recorded (17 IAC 4170.110). • Unregistered Grave - any grave or location (including any unmarked burial site) where a human body has been

buried or deposited, is over 100 years old, and is not in a cemetery registered with the State Comptroller under the Cemetery Care Act (17 IAC 4170.110).

Page 109: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

2-2 Cultural Resources Management

Page 110: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

2-3 Cultural Resources Management

CULTURAL RESOURCES MANAGEMENT GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: Missing Checklist Items CR.2.1.IL. Historic Properties CR.5.1.IL. Archaeological/Indian Sites CR.15.1.IL. and CR.15.2.IL.

Page 111: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

2-4 Cultural Resources Management

COMPLIANCE CATEGORY: CULTURAL RESOURCES MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

CR.2. MISSING CHECKLIST ITEMS

CR.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 112: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

2-5 Cultural Resources Management

COMPLIANCE CATEGORY: CULTURAL RESOURCES MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

CR.5. HISTORIC PROPERTIES

CR.5.1.IL. A Certificate of Compliance must be obtained prior to demolition of a Critical Historic Feature of a Registered Illinois Historic Place (20 Illinois Compiled Statutes (ILCS) Section 3410.7).

Verify that the facility does not demolish any Critical Historic Feature of a Registered Illinois Historic Place without first obtaining a Certificate of Compliance from the Director.

Page 113: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

2-6 Cultural Resources Management

Page 114: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

2-7 Cultural Resources Management

COMPLIANCE CATEGORY: CULTURAL RESOURCES MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

CR.15. ARCHAEOLOGICAL/ INDIAN SITES

CR.15.1.IL. Disturbances of unregistered graves or unmarked burials, and dis-coveries of human remains, must be reported (17 IAC 4170.200(a) through (c)).

Verify that any person knowing or having reasonable grounds to believe that an unregistered grave or unmarked burial site is being disturbed, destroyed, defaced, mutilated, removed, excavated, or exposed notifies the coroner of the county as soon as possible.

Verify that any person who discovers human remains notifies the county coroner as soon as possible.

Verify that any person knowing, or having reasonable grounds to believe, that an unregistered grave or unmarked burial site may be disturbed, destroyed, defaced, mutilated, removed, excavated or exposed, notifies the Agency as soon as possible prior to the disturbance.

Verify that, when any person discovers an unregistered grave (other than during an archaeological excavation subject to regulation by the Agency), all activity that may disturb the unregistered grave ceases immediately, the county coroner is notified immediately, and the activity is not resumed until authorized by the coroner or the Agency.

CR.15.2.IL. Persons seeking to disturb unregistered graves must submit an application for a permit prior to the proposed starting date of the activity (17 IAC 4170.300(a), (b), and (d)).

(NOTE: Nongovernmental owners that desire to remove human remains must apply to the Director for a permit; upon receipt, the Agency will assist the applicant in preparing a mitigation plan for the removal.)

Verify that governmental bodies seeking to disturb an unregistered grave submit an application for a permit to the Director at least 2 mo prior to the proposed start of construction or other field operations that would affect the unregistered grave.

(NOTE: No permit is required where the proposed archaeological work consists of an archaeological survey and/or data recovery undertaken pursuant to a signed Section 106 agreement.)

Page 115: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

3-1 Hazardous Materials Management

SECTION 3

HAZARDOUS MATERIALS MANAGEMENT

Illinois Supplement, June 2000 This section covers the Illinois requirements for Hazardous Materials Management and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Incorporation of Federal Regulations

Illinois incorporates the following Federal regulations by reference: - Title 49 Code of Federal Regulations, Part 172 (40 CFR 172) (incorporated at Title 92 Illinois Administrative

Code, Section 172.2000 (92 IAC 172.2000) - 49 CFR 173 (92 IAC 173.3000) - 49 CFR 177 (92 IAC 177.2000) - 49 CFR 178 (92 IAC 178.2000) - 49 CFR 179 (92 IAC 179.2000) - 49 CFR 180 (92 IAC 180.2000).

Definitions

• Bulk Storage - the storage of flammable or combustible liquid in an aboveground tank that is not for dispensing purposes (41 IAC 180.10).

• Combustible Liquid - a liquid having a flash point at or above 100 °F. Combustible liquids are subdivided into

the following categories (41 IAC 180.10): 1. Class II liquids - those having a flash point at or above 100 °F and below 140 °F 2. Class IIIA liquids - those having flash points at or above 140 °F and below 200 °F 3. Class IIIB liquids - those having a flash point at or above 200 °F.

• Container - any vessel of 60 gal or less capacity used for transporting or storing liquids (41 IAC 180.10). • Dispensing - the activity of transferring a flammable or combustible liquid from an aboveground storage tank to

a vehicle, mobile equipment, engine, or motor for use as fuel by them, or transference into a receptacle (41 IAC 180.10).

• Flammable Liquid - a liquid having a flash point below 100 °F and having a vapor pressure not exceeding 40

psia at 100 °F. Flammable liquids are further subdivided as (41 IAC 180.10): 1. Class IA - includes those liquids having a flash point below 73 °F and having a boiling point below 100 °F 2. Class IB - includes those liquids having a flash point below 73 °F and having a boiling point at or above

100 °F 3. Class IC - includes those liquids having a flash point at or above 73 °F and below 100 °F.

• Flash Point - the minimum temperature at which a liquid gives off vapor in sufficient concentration to form an

ignitable mixture with air near the surface of a liquid within the vessel (41 IAC 180.10). • NFPA - National Fire Protection Association (41 IAC 180.10).

Page 116: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

3-2 Hazardous Materials Management

HAZARDOUS MATERIALS MANAGEMENT

GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: Missing Checklist Items HM.2.1.IL. Releases of Hazardous Materials HM.20.1.IL. Flammable/Combustible Liquids

General HM.35.1.IL. through HM.35.10.IL. Industrial Areas HM.40.1.IL.

Page 117: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

3-3 Hazardous Materials Management

COMPLIANCE CATEGORY: HAZARDOUS MATERIALS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

HM.2. MISSING CHECKLIST ITEMS

HM.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 118: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

3-4 Hazardous Materials Management

COMPLIANCE CATEGORY: HAZARDOUS MATERIALS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

HM.20. RELEASES OF HAZARDOUS MATERIALS

HM.20.1.IL. Spills of Class I, II, or III liquids at fuel dispensing facilities must be reported (41 IAC180.20(g)).

Verify that the facility reports any spill of Class I, II, or III liquids in excess of 25 gal at any dispensing facility to the Illinois Emergency Services and Disaster Agency within 24 hr.

Page 119: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

3-5 Hazardous Materials Management

COMPLIANCE CATEGORY: HAZARDOUS MATERIALS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

FLAMMABLE/ COMBUSTIBLE LIQUIDS HM.35. GENERAL

HM.35.1.IL. Containers for flammable/combustible liquids must meet specific requirements (41 IAC 180.30).

Verify that all receptacles used for keeping or storing gasoline, naphtha, benzine [sic], or benzol are colored red, and no other liquids are kept in red containers.

Verify that containers used for keeping or storing flammable or combustible liquids are made of metal or of a type approved by the State Fire Marshal.

HM.35.2.IL. The use of flammable and combustible liquids inside buildings is restricted (41 IAC 180.50).

Verify that the mixing, storing, or handling of any Class I and II liquid in open containers is prohibited in any building.

Verify that the use of Class I or II liquids for cleaning floors or woodwork is avoided.

Verify that dry cleaning or removal of spots from clothing or other material with Class I or II liquids is done out of doors or in an approved dry cleaning facility.

HM.35.3.IL. Flammable and combustible liquids must not be poured into sewers (41 IAC 180.60).

Verify that Class I, II, or III liquids or solutions containing such liquids are not poured into any sewer or into any drain that connects with a sewer system.

HM.35.4.IL. Storage of flammable and combustible liquids in public buildings is restricted (41 IAC 180.70).

Verify that Class I or II liquids are not kept or stored in any schoolhouse, public hall, or place of assembly, or in any public building, except for demonstration, industrial, or mechanical use, and then only under competent supervision.

HM.35.5.IL. Flammable and combustible liquids must not be used to start or kindle fires (41 IAC 180.80).

Verify that flammable liquids are not used to start or kindle fires in stoves, furnaces, or other such devices.

Page 120: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

3-6 Hazardous Materials Management

COMPLIANCE CATEGORY: HAZARDOUS MATERIALS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

HM.35.6.IL. Flammable and combustible liquids must be kept from open flame or fire (41 IAC 180.90).

Verify that flammable liquids are always kept away from fire or open flame.

HM.35.7.IL. The storage of kerosene within buildings must meet specific requirements (41 IAC 180.20(d)) [Citation Revised May 1998].

Verify that no more than 12 gal of kerosene is stored indoors for use.

Verify that kerosene stored indoors for use is stored only in containers that meet the requirements of NFPA 30.

Verify that when 60 gal or less is stored in ASTs for retail sale within a building, the following requirements are met:

- storage is in a tank of 14 gauge steel or aluminum - the tank sits in a metal pan extending at least 8 in. beyond the sides and rear

of the tank and 18 in. beyond the front - the tank is located on the first floor in an area with natural light and

ventilation - the room or area where the tank is located is separated from any heat

producing appliance (except radiators and hot air ducts) by one-hour fire resistance

- the dispensing nozzle or spigot is spring loaded so as to return to the off position when pressure is released so pressure is constantly required to cause release of the kerosene

- the tank is blue in color and marked with the word KEROSENE in letters at least 2 1/2 in. high in contrasting color.

Verify that when 60 gal or less is stored in metal drums for retail trade within a

building, the storage meets the following requirements:

- the metal drum is stored in a storage cabinet that meet the requirements of 49 CFR Chapter I

- the storage cabinet sits in a metal pan extending at least 8 in. beyond the sides and rear of the storage cabinet

- the room or area where the storage cabinet is located is separated from any heat producing appliance such as a hot water heater, furnace, or space heater (except for radiators and heat ducts)

- the design and construction of storage cabinets is in accordance with NFPA 30.

(NOTE: Factory sealed containers of 1-K grade kerosene may be stored at a

facility for retail trade within a building in compliance with ASTM F 976-86 and NFPA 30.)

HM.35.8.IL. Warehouses Verify that any warehouse erected after 14 April 1977 or converted for the storage

Page 121: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

3-7 Hazardous Materials Management

COMPLIANCE CATEGORY: HAZARDOUS MATERIALS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

storing flammable liquids must meet specific require-ments (41 IAC 160.260).

of flammable liquids must be constructed to have noncombustible walls, roofs, and floors, and refuse cannot accumulate under the floor.

Verify that storage of Class I or II liquids is in the original sealed containers, and no transfer of such liquids to other containers is made inside the warehouse.

Verify that warehouses are kept clean, neat, orderly, and free from accumulation of grease and oil spillage.

HM.35.9.IL. Garages storing flammable liquids must meet specific requirements (41 IAC 160.270).

Verify that the garage floor is made of concrete or other noncombustible material, laid directly on the ground or on well tamped and puddled fill.

Verify that ventilation is provided to carry off any flammable gases that may accumulate.

Verify that there is no connection to any house drainage or sewer system from any garage waste basin, sink, floor drain, or waste unless a grease trap is provided ahead of such connection.

(NOTE: This does not apply to lavatories, toilets, or wash basins utilized exclusively for toilet or personnel use, nor to downspouts carrying surface water from the roof.)

HM.35.10.IL. Loading docks must meet specific siting, design, and equipment standards (41 IAC 160.290 and 160.300).

Verify that loading docks and platforms for flammable liquid storage areas are located not less than 25 ft from storage tanks, plant buildings, and property lines, except facilities existing before 14 April 1977, which must be no less than 10 ft from such structures.

Verify that all electric lights at loading and unloading docks are of vapor-proof construction, electric wiring is in sealed conduits, and switches are explosion-proof or placed at least 20 ft from the docks.

Verify that all electrical installations, appliances, equipment, and wiring conforms to NFPA Standard No. 70.

Page 122: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

3-8 Hazardous Materials Management

Page 123: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

3-9 Hazardous Materials Management

COMPLIANCE CATEGORY: HAZARDOUS MATERIALS MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

FLAMMABLE/ COMBUSTIBLE LIQUIDS

HM.40. INDUSTRIAL AREAS

HM.40.1.IL. The industrial use of flammable or combustible liquids must meet specific design and operational requirements (41 IAC 180.40).

Verify that flammable liquids used in mixers for mixing or cleaning are piped to mixers whenever feasible to avoid spillage and dispersion of flammable vapors.

Verify that automatic shutoff valves are provided to prevent overfilling of mixers.

Verify that Class I or II liquids are not drawn from containers within a building except by means of a device drawing from the top of the tank or container.

Verify that there is no gravity discharge of Class I or II liquids.

Verify that drums or barrels for storage of flammable liquids have taps, plugs, or bungs replaced immediately after the container is emptied and is removed to the outside.

Verify that hand tools, scrapers, and similar devices used in mixing are made of a material that will not produce sparks.

Verify that mixing rooms have adequate mechanical ventilation to prevent accumulation of flammable vapors.

Verify that fans operate whenever pumps or mixers are in operation.

Verify that mixing rooms are equipped with flammable vapor detector alarms to warn when vapors are approaching an explosive range.

Verify that approved dry powder or foam type automatic extinguishing devices are installed above mixers that use flammable liquids for mixing or cleaning.

Verify that design and installation of electrical equipment in mixing rooms where flammable liquids are used comply with the standards of the National Electrical Code, NFPA No. 70.

Page 124: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

4-1 Hazardous Waste Management

SECTION 4

HAZARDOUS WASTE MANAGEMENT

Illinois Supplement, June 2000 This section covers the Illinois requirements for Hazardous Waste Management and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements. Although Illinois does not incorporate the Federal hazardous waste regulations by reference, the Illinois regulations are substantially the same as the Federal regulations, with minor variations that are identified in the Section.

Page 125: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

4-2 Hazardous Waste Management

HAZARDOUS WASTE MANAGEMENT GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: Missing Checklist Items HW.2.1.IL. All Sizes of Generators HW.10.1.IL. Generators General HW.55.1.IL. All TSDFs Documentation HW.145.1.IL.

Page 126: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

4-3 Hazardous Waste Management

COMPLIANCE CATEGORY: HAZARDOUS WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

HW.2. MISSING CHECKLIST ITEMS

HW.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 127: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

4-4 Hazardous Waste Management

COMPLIANCE CATEGORY: HAZARDOUS WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

HW.10. ALL SIZES OF GENERATORS

HW.10.1.IL. Generators that transport, or offer for trans-port, hazardous waste must meet specific require-ments (35 IAC 722.112) [Citation Revised May 1999].

Verify that all of the following requirements are met:

- the transporter has a USEPA or Illinois Environmental Protection Agency (IEPA) identification number

- a manifest is completed, signed, and copies are provided for the transporter, the designated facility, secondary transporters, and facility records.

Page 128: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

4-5 Hazardous Waste Management

COMPLIANCE CATEGORY: HAZARDOUS WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

GENERATORS HW.55. GENERAL

HW.55.1.IL. Hazardous waste generators must submit an annual report (35 IAC 722.141).

(NOTE: State reporting requirements are identical to the Federal, except: - the state report is submitted annually instead of every 2 yr - small quantity generators (SQGs) are exempt.)

Verify that hazardous waste generators submit a report to the IEPA no later than 1 March each year.

Page 129: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

4-6 Hazardous Waste Management

COMPLIANCE CATEGORY: HAZARDOUS WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ALL TSDFs HW.145. DOCUMENTATION

HW.145.1. TSDFs must submit an annual report (35 IAC 724.175).

(NOTE: This requirement is identical to the Federal, except that it requires an annual report instead of a biennial report.)

Verify that the TSDF submits a report to the IEPA no later than 1 March each year on a form supplied by the Agency.

Page 130: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-1 Natural Resources Management

SECTION 5

NATURAL RESOURCES MANAGEMENT

Illinois Supplement, June 2000 This section covers the Illinois requirements for Natural Resources Management and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Definitions

• Animal Product - the fur, hide, skin, teeth, feathers, tusks, claws, eggs, nests or the body or any portion thereof whether in a green or raw state or as a product manufactured or refined from an animal protected under the Illinois Endangered Species Act or under rules issued pursuant to that Act (Title 17, Illinois Administrative Code, Section 1070.10 (17 IAC 1070.10)).

• Department - Illinois Department of Conservation (17 IAC 1070.10). • Plant Product - any plant body or part thereof removed from natural habitat, including seeds, fruits, roots, stems,

flowers, leaves, or products made from any of these including extracts and powders (17 IAC 1070.10). • Take - in reference to animals and animal products, to harm, hunt, shoot, pursue, lure, wound, kill, destroy,

harass, gig, spear, ensnare, trap, capture, collect, or to attempt to engage in such conduct. In reference to plants and plant products, to collect, pick, cut, dig up, kill, destroy, bury, crush, or harm in any way (17 IAC 1070.10).

Page 131: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-2 Natural Resources Management

NATURAL RESOURCES MANAGEMENT GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: Missing Checklist Items NR.2.1.IL. Wildlife NR.20.1.IL.

GUIDANCE FOR ILLINOIS APPENDIX USERS

REFER TO APPENDIX NUMBER: REFER TO APPENDIX ITEMS:

5-1

Endangered and Threatened Animal Species of Illinois

Page 132: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-3 Natural Resources Management

COMPLIANCE CATEGORY: NATURAL RESOURCES MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

NR.2. MISSING CHECKLIST ITEMS

NR.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 133: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-4 Natural Resources Management

COMPLIANCE CATEGORY: NATURAL RESOURCES MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

NR.20. WILDLIFE

NR.20.1.IL. Permits must be obtained prior to taking an endangered or threatened animal or plant (17 IAC 1070.20) [Revised May 1998].

Verify that the facility does not take, possess, transport, purchase, or dispose of specimens or products of an endangered or threatened animal or Federal endangered plant unless a valid permit has been issued (see Appendix 5-1).

Page 134: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-5 Natural Resources Management

Appendix 5-1

Endangered and Threatened Animal Species of Illinois

(Source: Checklist of Endangered and Threatened Animals and Plants of Illinois, Illinois Endangered Species Protection Board) [Revised June 2000]

(NOTE: This list is kept current and is available through the Illinois Endangered Species Protection Board at dnr.state.il.us/espb/index.htm.) ** Federally Endangered Species: Any species which is in danger of extinction throughout all or a significant portion of its range.

* Federally Threatened Species: Any species which is likely to become an endangered species within the foreseeable future throughout all or a significant portion of its range.

Illinois Endangered Species: Any species which is in danger of extinction as a breeding species in Illinois.

State Threatened Species: Any breeding species which is likely to become a state endangered species within the foreseeable future in Illinois.

FISH

Endangered

Acipenser fulvescens (lake sturgeon)

Etheostoma camurum (bluebreast darter)

Etheostoma exile (Iowa darter)

Etheostoma histrio (Harlequin darter)

Hybognathus hayi (cypress minnow)

Ichthyomyzon fossor (northern brook lamprey)

Macrhybopsis gelida (sturgeon chub)

Moxostoma valenciennesi (greater redhorse)

Nocomis micropogon (river chub)

Notropis anogenus (pugnose shiner)

Notropis boops (bigeye shiner)

Notropis heterolepis (blacknose shiner)

Notropis maculatus (taillight shiner)

Notropis texanus (weed shiner)

Threatened

Catostomus catostomus (longnose sucker)

Coregonus artedi (cisco or lake herring)

Fundulus diaphanus (banded killifish)

Lampetra aepyptera (least brook lamprey)

Lepomis symmetricus (bantam sunfish)

Moxostoma carinatum (river redhorse)

Notropis chalybaeus (ironcolor shiner)

Notropis heterodon (blackchin shiner)

Page 135: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-6 Natural Resources Management

Noturus stigmosus (northern madtom)

Platygobio gracilis (flathead chub)

Pteronotropis hubbsi (bluehead shiner)

Scaphirhynchus albus (pallid sturgeon)**

AMPHIBIANS

Endangered

Ambystoma x platineum (silvery salamander)

Cryptobranchus alleganiensis (hellbender)

Desmognathus fuscus (dusky salamander)

Threatened

Ambystoma jeffersonianum (Jefferson salamander)

Hemidactylium scutatum (four-toed salamander)

Hyla avivoca (bird-voiced treefrog)

Pseudacris streckeri illinoensis (Illinois chorus frog)

REPTILES

Endangered

Clemmys guttata (spotted turtle)

Kinosternon flavescens (Illinois mud turtle)

Macroclemys temminckii (alligator snapping turtle)

Masticophis flagellum (coachwhip)

Nerodia fasciata (broad-banded water snake)

Pseudemys concinna (river cooter)

Sistrurus catenatus catenatus (eastern massasauga)

Thamnophis sauritus (eastern ribbon snake)

Threatened

Clonophis kirtlandii (Kirtland's snake)

Crotalus horridus (timber rattlesnake)

Elaphe guttata emoryi (great plains rat snake)

Emydoidea blandingii (Blanding's turtle)

Heterodon nasicus (western hognose snake)

Nerodia cyclopion (Mississippi green water snake)

Tantilla gracilis (flathead snake)

BIRDS

Endangered Threatened

Page 136: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-7 Natural Resources Management

Ammodramus henslowii (Henslow's sparrow)

Asio flammeus (short-eared owl)

Bartramia longicauda (upland sandpiper)

Botaurus lentiginosus (American bittern)

Buteo swainsoni (Swainson's hawk)

Charadrius melodus (piping plover)**

Chlidonias niger (black tern)

Circus cyaneus (northern harrier)

Egretta caerulea (little blue heron)

Egretta thula (snowy egret)

Falco peregrinus (peregrine falcon)

Ictinia mississippiensis (Mississippi kite)

Laterallus jamaicensis (black rail)

Limnothlypis swainsonii (Swainson's warbler)

Nyctanassa violacea (yellow-crowned night-heron)

Nycticorax nycticorax (black-crowned night-heron)

Pandion haliaetus (osprey)

Phalaropus tricolor (Wilson's phalarope)

Rallus elegans (king rail)

Sterna antillarum (least tern)**

Sterna forsteri (Forster's tern)

Sterna hirundo (common tern)

Thryomanes bewickii (Bewick's wren)

Tympanuchus cupido (greater prairie-chicken)

Tyto alba (common barn-owl)

Xanthocephalus xanthocephalus (yellow-headed blackbird)

Buteo lineatus (red-shouldered hawk)

Certhia americana (brown creeper)

Gallinula chloropus (common moorhen)

Grus canadensis (sandhill crane)

Haliaeetus leucocephalus (bald eagle)*

Ixobrychus exilis (least bittern)

Lanius ludovicianus (loggerhead shrike)

Podilymbus podiceps (pied-billed grebe)

Page 137: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-8 Natural Resources Management

MAMMALS

Endangered

Corynorhinus rafinesquii (eastern big-eared bat)

Myotis austroriparius (southeastern bat)

Myotis grisescens (gray bat)**

Myotis sodalis (Indiana bat)**

Neotoma floridana (eastern woodrat)

Threatened

Lontra canadensis (river otter)

Ochrotomys nuttalli (golden mouse)

Oryzomys palustris (marsh rice rat)

INVERTEBRATES

Endangered

Snails

Discus macclintocki (pleistocene disc)**

Mussels

Cumberlandia monodonta (spectacle case mussel)

Cyprogenia stegaria (fanshell mussel)**

Epioblasma triquetra (snuffbox mussel)

Lampsilis abrupta (pink mucket)**

Lampsilis fasciola (wavy-rayed lampmussel)

Lampsilis higginsii (Higgins eye)**

Obovaria subrotunda (round hickorynut mussel)

Plethobasus cooperianus (orange-foot pimpleback)**

Plethobasus cyphyus (sheepnose mussel)

Pleurobema clava (clubshell mussel)**

Pleurobema cordatum (Ohio pigtoe)

Pleurobema rubrum (pyramid pigtoe)

Potamilus capax (fat pocketbook pearly mussel)**

Threatened

Mussels

Alasmidonta viridis (slippershell mussel)

Cyclonaias tuberculata (purple wartyback)

Ellipsaria lineolata (butterfly)

Elliptio crassidens (elephant-ear mussel)

Elliptio dilatata (spike)

Fusconaia ebena (ebonyshell)

Ligumia recta (black sandshell)

Crustaceans

Gammarus bousfieldi (Bousfield's amphipod)

Dragonflies

Nannothemis bella (elfin skimmer)

Leafhoppers

Aflexia rubranura (redveined prairie leafhopper)

Butterflies and Moths

Hesperia metea (cobweb skipper)

Page 138: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-9 Natural Resources Management

Ptychobranchus fasciolaris (kidneyshell mussel)

Quadrula cylindrica (rabbitsfoot mussel)

Simpsonaias ambigua (salamander mussel)

Toxolasma lividus (purple lilliput mussel)

Villosa fabalis (rayed bean mussel)

Villosa iris (rainbow mussel)

Villosa lienosa (little spectacle case mussel)

Crustaceans

Caecidotea lesliei (isopod)

Crangonyx anomalus (amphipod)

Crangonyx antennatus (amphipod)

Crangonyx packardi (amphipod)

Gammarus acherondytes (Illinois cave amphipod)**

Orconectes indianensis (Indiana crayfish)

Orconectes kentuckiensis (Kentucky crayfish)

Orconectes lancifer (oxbow crayfish)

Orconectes placidus (crayfish)

Stygobromus iowae (Iowa amphipod)

Dragonflies

Somatochlora hineana (Hine's emerald dragonfly)**

Leafhoppers

Paraphlepsius lupalus (leafhopper)

Butterflies and Moths

Atrytone arogos (arogos skipper)

Calephelis muticum (swamp metalmark)

Lycaeides melissa samuelis (Karner blue butterfly)**

Papaipema eryngii (rattlesnake-master borer moth)

Hesperia ottoe (ottoe skipper)

Speyeria idalia (regal fritillary)

Page 139: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-10 Natural Resources Management

LICHENS

Endangered

Phaeophyscia leana (Lea's bog lichen)

PLANTS

Endangered

Adoxa moschatellina (moschatel)

Alnus incana ssp rugosa (speckled alder)

Amelanchier interior (shadbush)

Amelanchier sanguinea (shadbush)

Ammophila breviligulata (beach grass)

Amorpha nitens (smooth false indigo)

Arctostaphylos uva-ursi (bearberry)

Artemisia dracunculus (false tarragon)

Asclepias lanuginosa (woolly milkweed)

Asclepias meadii (Mead's milkweed)*

Asclepias ovalifolia (oval milkweed)

Asclepias stenophylla (narrow-leaved green milkweed)

Asplenium bradleyi (Bradley's spleenwort)

Asplenium resiliens (black spleenwort)

Astragalus crassicarpus var trichocalyx (large ground plum)

Astragalus tennesseensis (Tennessee milk-vetch)

Bartonia paniculata (screwstem)

Beckmannia syzigachne (American slough grass)

Berberis canadensis (Allegheny barberry)

Berchemia scandens (supple-jack)

Threatened

Agalinis skinneriana (pale false foxglove)

Arenaria patula (slender sandwort)

Aristolochia serpentaria var hastata (narrow-leaved snakeroot)

Aster furcatus (forked aster)

Besseya bullii (kitten tails)

Boltonia decurrens (decurrent false aster)*

Botrychium biternatum (southern grape fern)

Cakile edentula (sea rocket)

Carex communis (fibrous-rooted sedge)

Carex intumescens (swollen sedge)

Carex oxylepis (sharp-scaled sedge)

Carex prasina (drooping sedge)

Carex viridula (little green sedge)

Carex willdenowii (Willdenow's sedge)

Carex woodii (pretty sedge)

Chamaedaphne calyculata (leatherleaf)

Cimicifuga rubifolia (black cohosh)

Cirsium hillii (Hill's thistle)

Cirsium pitcheri (Pitcher's (dune) thistle)*

Corallorhiza maculata (spotted coral-root orchid)

Page 140: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-11 Natural Resources Management

Betula alleghaniensis (yellow birch)

Betula populifolia (gray birch)

Bidens beckii (water marigold)

Botrychium matricariifolium (daisyleaf grape fern)

Botrychium multifidum (northern grape fern)

Botrychium simplex (grape fern)

Bouteloua gracilis (blue grama)

Bumelia lanuginosa (wooly buckthorn)

Calamagrostis insperata (bluejoint grass)

Calla palustris (water arum)

Calopogon tuberosus (grass pink orchid)

Camassia angusta (wild hyacinth)

Cardamine pratensis var palustris (cuckoo flower)

Carex alata (winged sedge)

Carex arkansana (Arkansas sedge)

Carex aurea (golden sedge)

Carex brunnescens (brownish sedge)

Carex canescens var disjuncta (silvery sedge)

Carex chordorrhiza (cordroot sedge)

Carex crawfordii (crawford sedge)

Carex cryptolepis (sedge)

Carex decomposita (cypress-knee sedge)

Carex disperma (shortleaf sedge)

Carex echinata (little prickly sedge)

Carex garberi (elk sedge)

Carex gigantea (large sedge)

Carex lucorum (sedge)

Cyperus grayioides (Gray's umbrella sedge)

Cypripedium candidum (white lady's-slipper orchid)

Drosera intermedia (narrow-leaved sundew)

Eleocharis rostellata (beaked spike rush)

Epilobium strictum (downy willow herb)

Equisetum pratense (meadow horsetail)

Erythronium mesochoreum (white dog-tooth violet)

Eupatorium incarnatum (thoroughwort)

Galium labradoricum (bog bedstraw)

Helianthus angustifolius (narrow-leaved sunflower)

Juniperus communis (common juniper)

Lactuca hirsuta (wild lettuce)

Larix laricina (tamarack)

Lathyrus ochroleucus (pale vetchling)

Lechea intermedia (pinweed)

Liatris scariosa var nieuwlandii (blazing star)

Matelea obliqua (climbing milkweed)

Melanthium virginicum (bunch-flower)

Melothria pendula (squirting cucumber)

Oenothera perennis (small sundrops)

Orobanche ludoviciana (broomrape)

Planera aquatica (water elm)

Potamogeton gramineus (pondweed)

Quercus montana (rock chestnut oak)

Quercus phellos (willow oak)

Ranunculus rhomboideus (prairie buttercup)

Rhynchospora alba (beaked rush)

Page 141: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-12 Natural Resources Management

Carex nigromarginata (black-edged sedge)

Carex oligosperma (few-seeded sedge)

Carex physorhyncha (Bellow's-beak sedge)

Carex reniformis (reniform sedge)

Carex striatula (lined sedge)

Carex trisperma (three-seeded sedge)

Carex tuckermanii (Tuckerman's sedge)

Carya pallida (pale hickory)

Castilleja sessiliflora (downy yellow painted cup)

Ceanothus herbaceus (redroot)

Chamaesyce polygonifolia (seaside spurge)

Chimaphila maculata (spotted wintergreen)

Chimaphila umbellata (pipsissewa)

Cimicifuga americana (American bugbane)

Cimicifuga racemosa (black cohosh)

Circaea alpina (small enchanter's nightshade)

Cladrastis lutea (yellowwood)

Clematis crispa (blue jasmine)

Clematis occidentalis (mountain clematis)

Clematis viorna (leatherflower)

Collinsia violacea (violet collinsia)

Comptonia peregrina (sweet-fern)

Conioselinum chinense (hemlock parsley)

Cornus canadensis (bunchberry)

Corydalis aurea (golden corydalis)

Corydalis halei (Hale's corydalis)

Corydalis sempervirens (pink corydalis)

Rubus pubescens (dwarf raspberry)

Salvia azurea ssp pitcheri (blue sage)

Scirpus hallii (Hall's bulrush)

Scirpus polyphyllus (leafy bulrush)

Solidago sciaphila (cliff goldenrod)

Styrax americana (storax)

Sullivantia renifolia (sullivantia)

Thuja occidentalis (arbor vitae)

Tofieldia glutinosa (false asphodel)

Tomanthera auriculata (earleaf foxglove)

Tradescantia bracteata (prairie spiderwort)

Trientalis borealis (star-flower)

Triglochin maritimum (arrow-grass)

Triglochin palustris (arrow-grass)

Urtica chamaedryoides (nettle)

Veratrum woodii (false hellebore)

Veronica scutellata (marsh-speedwell)

Viburnum molle (arrowwood)

Viola conspersa (dog violet)

Page 142: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-13 Natural Resources Management

Corylus rostrata (beaked hazelnut)

Cynosciadium digitatum (finger dog-shade)

Cyperus lancastriensis (galingale)

Cypripedium acaule (lady's-slipper orchid)

Cypripedium parviflorum (small yellow lady's-slipper orchid)

Cypripedium reginae (showy lady's-slipper orchid)

Cystopteris x laurentiana (laurentian fragile fern)

Dalea foliosa (leafy prairie clover)**

Dennstaedtia punctilobula (hay-scented fern)

Draba cuneifolia (whitlow grass)

Drosera rotundifolia (round-leaved sundew)

Dryopteris celsa (log fern)

Echinodorus tenellus (small burhead)

Eleocharis olivacea (capitate spike rush)

Eleocharis pauciflora (few-flowered spike rush)

Equisetum scirpoides (dwarf scouring rush)

Equisetum sylvaticum (horsetail)

Eriophorum virginicum (rusty cotton grass)

Eryngium prostratum (eryngo)

Euonymus americanus (strawberry bush)

Euphorbia spathulata (spurge)

Filipendula rubra (queen-of-the-prairie)

Fimbristylis vahlii (Vahl's fimbristylis)

Galactia mohlenbrockii (Boykin's dioclea)

Galium lanceolatum (wild licorice)

Galium virgatum (dwarf bedstraw)

Gaultheria procumbens (wintergreen)

Page 143: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-14 Natural Resources Management

Geranium bicknellii (northern cranesbill)

Glyceria arkansana (manna grass)

Gymnocarpium dryopteris (oak fern)

Gymnocarpium robertianum (scented oak fern)

Hackelia americana (stickseed)

Halesia carolina (silverbell tree)

Helianthus giganteus (tall sunflower)

Heliotropium tenellum (slender heliotrope)

Heteranthera reniformis (mud plantain)

Hexalectris spicata (crested coral-root orchid)

Hudsonia tomentosa (false heather)

Hydrocotyle ranunculoides (water-pennywort)

Hydrolea uniflora (one-flowered hydrolea)

Hymenoxys herbacea (lakeside daisy)*

Hypericum adpressum (shore St. John's wort)

Hypericum kalmianum (kalm St. John's-wort)

Iliamna remota (Kankakee mallow)

Iresine rhizomatosa (bloodleaf)

Isoetes butleri (quillwort)

Isotria medeoloides (small whorled pogonia)

Isotria verticillata (whorled pogonia)*

Juncus alpinus (Richardson's rush)

Juncus vaseyi (Vasey's rush)

Juniperus horizontalis (trailing juniper)

Justicia ovata (water willow)

Lathyrus japonicus var glaber (beach pea)

Lespedeza leptostachya (prairie bush clover)*

Page 144: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-15 Natural Resources Management

Lesquerella ludoviciana (silvery bladder pod)

Lonicera dioica var glaucescens (red honeysuckle)

Lonicera flava (yellow honeysuckle)

Luzula acuminata (wood rush)

Lycopodium clavatum (common clubmoss)

Lycopodium dendroideum (ground pine)

Lycopodium inundatum (bog clubmoss)

Lysimachia fraseri (loosestrife)

Lysimachia radicans (creeping loosestrife)

Malus angustifolia (narrow-leaved crabapple)

Matelea decipiens (climbing milkweed)

Medeola virginiana (indian cucumber root)

Melanthera nivea (white melanthera)

Melica mutica (two-flowered melic grass)

Milium effusum (millet grass)

Mimulus glabratus (yellow monkeyflower)

Mirabilis hirsuta (hairy umbrella-wort)

Nothocalais cuspidata (prairie dandelion)

Opuntia fragilis (fragile prickly pear)

Orobanche fasciculata (clustered broomrape)

Oxalis illinoensis (Illinois wood sorrel)

Panicum boreale (northern panic grass)

Panicum columbianum (panic grass)

Panicum joorii (panic grass)

Panicum ravenelii (Ravenel's panic grass)

Panicum yadkinense (panic grass)

Paspalum dissectum (bead grass)

Page 145: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-16 Natural Resources Management

Penstemon brevisepalus (short-sepaled beardstongue)

Penstemon grandiflorus (large-flowered beardtongue)

Phacelia gilioides (phacelia)

Phlox pilosa ssp sangamonensis (sangamon phlox)

Pinus banksiana (jack pine)

Pinus echinata (shortleaf pine)

Pinus resinosa (red pine)

Plantago cordata (heart-leaved plantain)

Platanthera ciliaris (yellow fringed orchid)

Platanthera clavellata (wood orchid)

Platanthera flava var flava (tubercled orchid)

Platanthera flava var herbiola (tubercled orchid)

Platanthera leucophaea (white fringed orchid)*

Platanthera psycodes (purple fringed orchid)

Poa alsodes (woodland bluegrass)

Poa languida (woodland bluegrass)

Poa wolfii (meadow bluegrass)

Pogonia ophioglossoides (snake-mouth)

Polanisia jamesii (James clammyweed)

Polygala incarnata (pink milkwort)

Polygonatum pubescens (small solomon's seal)

Polygonum arifolium (halbred-leaved tearthumb)

Polygonum careyi (Carey's smartweed)

Populus balsamifera (balsam poplar)

Potamogeton praelongus (pondweed)

Potamogeton pulcher (pondweed)

Potamogeton robbinsii (pondweed)

Page 146: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-17 Natural Resources Management

Potamogeton strictifolius (pondweed)

Potentilla millegrana (cinquefoil)

Primula mistassinica (bird's-eye primrose)

Ptilimnium nuttallii (mock bishop's weed)

Puccinellia pallida (pale manna-grass)

Pycnanthemum albescens (white mountain mint)

Pycnanthemum torrei (mountain mint)

Quercus nuttallii (Nuttall's oak)

Ranunculus cymbalaria (seaside crowfoot)

Rhamnus alnifolia (alder buckthorn)

Rhynchospora glomerata (clustered beaked rush)

Ribes hirtellum (northern gooseberry)

Rosa acicularis (rose)

Rubus odoratus (purple flowering raspberry)

Rubus setosus (bristly blackberry)

Rudbeckia missouriensis (Missouri orange coneflower)

Sabatia campestris (prairie rose gentian)

Sagittaria longirostra (arrowleaf)

Salix serissima (autumn willow)

Salix syrticola (sand-dune willow)

Sambucus pubens (red-berried elder)

Sanguisorba canadensis (American burnet)

Sarracenia purpurea (pitcher plant)

Saxifraga virginiensis (early saxifrage)

Schizachne purpurascens (false melic grass)

Scirpus cespitosus (tufted bulrush)

Scirpus hattorianus (bulrush)

Page 147: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-18 Natural Resources Management

Scirpus paludosus (alkali bulrush)

Scirpus purshianus (weak bulrush)

Scirpus smithii (Smith's bulrush)

Scirpus verecundus (bashful bulrush)

Shepherdia canadensis (buffalo berry)

Silene ovata (ovate catchfly)

Silene regia (royal catchfly)

Silphium trifoliatum (rosinweed)

Sisyrinchium atlanticum (blue-eyed grass)

Sisyrinchium montanum (blue-eyed grass)

Sorbus americana (American mountain-ash)

Sparganium americanum (bur-reed)

Sparganium chlorocarpum (greenfruited bur-reed)

Spiranthes lucida (yellow-lipped ladies' tresses)

Spiranthes romanzoffiana (hooded ladies' tresses)

Spiranthes vernalis (ladies' tresses)

Stellaria pubera (great chickweed)

Stenanthium gramineum (grass-leaved lily)

Stylisma pickeringii (patterson bindweed)

Styrax grandifolia (bigleaf snowbell bush)

Symphoricarpos albus var albus (snowberry)

Synandra hispidula (hairy synandra)

Talinum calycinum (large flower-of-an-hour)

Thalia dealbata (powdery thalia)

Thelypteris noveboracensis (New York fern)

Thelypteris phegopteris (long beech fern)

Tilia heterophylla (white basswood)

Page 148: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

5-19 Natural Resources Management

Triadenum virginicum (marsh St. John's wort)

Trichomanes boschianum (filmy fern)

Trifolium reflexum (buffalo clover)

Trillium cernuum (nodding trillium)

Trillium erectum (purple trillium)

Trillium viride (green trillium)

Ulmus thomasii (rock elm)

Utricularia cornuta (horned bladderwort)

Utricularia intermedia (flatleaf bladderwort)

Utricularia minor (small bladderwort)

Vaccinium corymbosum (highbush blueberry)

Vaccinium macrocarpon (large cranberry)

Vaccinium oxycoccos (small cranberry)

Valeriana uliginosa (marsh valerian)

Valerianella chenopodiifolia (corn salad)

Valerianella umbilicata (corn salad)

Veronica americana (American brookline)

Viola canadensis (Canada violet)

Viola incognita (hairy white violet)

Viola primulifolia (primrose-leaf violet)

Viola viarum (plains violet)

Waldsteinia fragarioides (barren strawberry)

Woodsia ilvensis (rusty woodsia)

Zigadenus glaucus (white camass)

Page 149: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

6-1 Other Environmental Issues

SECTION 6

OTHER ENVIRONMENTAL ISSUES

Illinois Supplement, June 2000 This section covers the Illinois requirements for Other Environmental Issues and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Page 150: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

6-2 Other Environmental Issues

OTHER ENVIRONMENTAL ISSUES GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS (NOTE: The page numbers referenced in the electronic copy of this protocol may not be consistent with the page numbers in any printed copy.) The NEPA Process Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Missing Checklist Items O1.2.1.IL. Environmental Noise

Missing Checklist Items O2.2.1.IL. State-Specific Requirements O2.5.1.IL.

IRP Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Missing Checklist Items O3.2.1.IL. Pollution Prevention Refer to the U.S. TEAM Guide and the DOD Component Supplements for DOD and service-specific requirements.

Missing Checklist Items O4.2.1.IL. Program Management Refer to the U.S. TEAM Guide and the DOD Component Supplements for DOD and service-specific requirements.

Page 151: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

6-3 Other Environmental Issues

COMPLIANCE CATEGORY: OTHER ENVIRONMENTAL ISSUES

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

NEPA O1.2. Missing Checklist Items

O1.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 152: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

6-4 Other Environmental Issues

COMPLIANCE CATEGORY: OTHER ENVIRONMENTAL ISSUES

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ENVIRONMENTAL NOISE O2.2. Missing Checklist Items

O2.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 153: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

6-5 Other Environmental Issues

COMPLIANCE CATEGORY: OTHER ENVIRONMENTAL ISSUES

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ENVIRONMENTAL NOISE O2.5. STATE-SPECIFIC REQUIREMENTS

O2.5.3.IL. Motor vehicles must be operated within specific sound limits (35 IAC 902.120 through 902.125).

Verify that all passenger cars and other motor vehicles with a gross weight of 8000 lb or less (except motorcycles and motor driven cycles) are operated so as not to exceed the following noise limitations:

- on highways with speed limits of 35 mph or less, 74 dB (A), or 76 dB (A) when operating on a grade exceeding 3 percent

- on highways with speed limits of more than 35 mph, 82 dB (A), or 85 dB (A) if the vehicle is equipped with two or more snow or mud/snow tires.

Verify that all motor vehicles with a gross weight in excess of 8000 lb are operated

so as not to exceed the following noise limitations under any conditions of highway grade, load, acceleration, or deceleration:

- on highways with speed limits of 35 mph or less, 86 dB (A) - on highways with speed limits of more than 35 mph, 90 dB (A).

(NOTE: The above sound level limits are as measured with fast meter response at 50 ft from the centerline of lane of travel, or an equivalent sound level limit measured in accordance with established procedure.)

Verify that motorcycles are operated in such a manner as not to exceed the following noise limitations:

- on highways with speed limits of 35 mph or less, 80 dB (A), or 82 dB (A) when operating on a grade exceeding 3 percent

- on highways with speed limits of more than 35 mph, 86 dB (A).

Page 154: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

6-6 Other Environmental Issues

COMPLIANCE CATEGORY: OTHER ENVIRONMENTAL ISSUES

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

IRP O3.2. Missing Checklist Items

O3.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 155: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

6-7 Other Environmental Issues

COMPLIANCE CATEGORY: OTHER ENVIRONMENTAL ISSUES

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

POLLUTION PREVENTION O4.2. Missing Checklist Items

O4.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 156: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-1 Pesticide Management

SECTION 7

PESTICIDE MANAGEMENT

Illinois Supplement, June 2000 This section covers the Illinois requirements for Pesticide Management and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Definitions

• Adulterated - any pesticide if the strength or purity is not within the standard of quality expressed on the labeling under which it is sold, distributed, or used, including any substance which has been substituted wholly or in part for the pesticide as specified on the labeling, or if any valuable constituent of the pesticide has been wholly or in part abstracted (Illinois Pesticide Act para. 804).

• Application - the spreading of lawn care products on a lawn (415 ILCS 65/2) [Added June 2000]. • Applicator For Hire - any person who makes an application of lawn care products to a lawn or lawns for

compensation, including applications made by an employee to lawns owned, occupied or managed by his employer and includes those licensed by the Department as licensed commercial applicators, commercial not-for-hire applicators, licensed public applicators, certified applicators and licensed operators and those otherwise subject to the licensure provisions of the Illinois Pesticide Act, as now or hereafter amended [415 ILCS 60/1 et seq.] (415 ILCS 65/2) [Added June 2000].

• Commercial Structural Pest Control Business - any business in the course of which any person advertises or

contracts to perform structural pest control services on property under the ownership or control of another in exchange for any consideration (225 ILCS 235/3) [Added June 2000].

• Commercial Structural Pest Control Business Location - any location at or from which any person advertises or

contracts to perform structural pest control services for hire or where a person is engaged or employed by that business to perform the services, store materials, keep records, or perform other pertinent activities, for the purpose of operating a structural pest control business at that business location, but does not include locations which exist solely for the purpose of accepting telephone calls and messages on behalf of the licensee (225 ILCS 235/3) [Added June 2000].

• Certified Technician - for the purposes of the structural pest control regulations, an individual who has met the

qualifications set forth under Section 5 of this Act [225 ILCS 235/5] (225 ILCS 235/3) [Added June 2000]. • Department - for the purposes of the structural pest control regulations, the Department of Public Health (225

ILCS 235/3) [Added June 2000]. • Device - for the purposes of the structural pest control regulations, any instrument or contrivance, other than a

firearm or equipment for application of pesticides when sold separately from pesticides, which is intended for trapping, repelling, destroying, or mitigating any pest, other than bacteria, virus, or other microorganisms on or living in man or other living animals (225 ILCS 235/3) [Added June 2000].

• Director - for the purposes of the structural pest control regulations, the Director of Public Health (225 ILCS

235/3) [Added June 2000].

Page 157: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-2 Pesticide Management

• Director - the Director of the Illinois Department of Agriculture or his designated representative (Illinois Pesticide Act para. 804).

• Equipment - any type of instruments and contrivances using motorized, mechanical, or pressure power which is

used to apply any pesticide, excluding pressurized hand-sized household apparatus containing dilute ready to apply pesticide or used to apply household pesticides (Illinois Pesticide Act para. 804).

• Facility - a building or structure and appurtenances thereto used by an applicator for hire for storage and

handling of pesticides or the storage or maintenance of pesticide application equipment or vehicles (415 ILCS 65/2) [Added June 2000].

• General Use Pesticide - for the purposes of the structural pest control regulations, any substance or mixture of

substances intended for preventing, destroying, repelling or mitigating any pest, as defined in Section 3.07 of this Act [225 ILCS 235/3.07], the use of which has been categorized as general under subparagraph (B) of paragraph (l) of subsection (d) of Section 3 of FIFRA [7 U.S.C. § 136a (225 ILCS 235/3) [Added June 2000]].

• Golf Course - an area designated for the play or practice of the game of golf, including surrounding grounds,

trees, ornamental beds and the like (415 ILCS 65/2) [Added June 2000]. • Golf Course Superintendent - any person entrusted with and employed for the care and maintenance of a golf

course (415 ILCS 65/2) [Added June 2000]. • Label - the written, printed, or graphic matter on or attached to the pesticide or device or any of its containers or

wrappings (Illinois Pesticide Act para. 804). • Lawn - land area covered with turf kept closely mown or land area covered with turf and trees or shrubs. The

term does not include (1) land area used for research for agricultural production or for the commercial production of turf, (2) land area situated within a public or private right-of-way, or (3) land area which is devoted to the production of any agricultural commodity, including, but not limited to plants and plant parts, livestock and poultry and livestock or poultry products, seeds, sod, shrubs and other products of agricultural origin raised for sale or for human or livestock consumption (415 ILCS 65/2) [Added June 2000].

• Lawn Care Products - fertilizers or pesticides applied or intended for application to lawns (415 ILCS 65/2)

[Added June 2000]. • Licensed Public Applicator - a certified applicator who uses or supervises the use of pesticides classified for

general or restricted use as an employee of a state agency, municipality, or other duly constituted governmental agency or unit (Illinois Pesticide Act para. 804).

• Non-commercial Structural Pest Control - structural pest control performed by a person who is not, and is not

employed by, a commercial structural pest control business (225 ILCS 235/3) [Added June 2000]. • Non-commercial Structural Pest Control Location - any location from which a person, who is not engaged in

commercial structural pest control, performs structural pest control activities which are confined to structures directly associated with the activity, business, product or service of such person (225 ILCS 235/3) [Added June 2000].

• Pest - any insect, rodent, nematode, fungus, weed, or any other form of terrestrial or aquatic plant or animal life

or microorganism which the Director declares a pest (Illinois Pesticide Act para. 804). • Pests - for the purposes of the structural pest control regulations,include arthropods (insects, spiders, mites, ticks

and related pests), wood infesting organisms, rats, mice, nuisance birds and any other obnoxious or undesirable

Page 158: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-3 Pesticide Management

animals in, on or under structures, but does not include bacteria or other micro-organisms on or in living man or other living animals (225 ILCS 235/3) [Added June 2000].

• Plant Protectants - any substance or material used to protect plants from infestation of insects, fungi, weeds and

rodents, or any other substance that would benefit the overall health of plants (415 ILCS 65/2) [Added June 2000].

• Restricted Pesticide - for the purposes of the structural pest control regulations, any substance or mixture of

substances intended for preventing, destroying, repelling, or mitigating any pest, the use of which has been categorized as restricted under subparagraph (C) of paragraph (l) of subsection (d) of Section 3 of the Federal Insecticide, Fungicide, Rodenticide Act as amended [7 U.S.C. § 136a] or under the Illinois Pesticide Act [415 ILCS 60/1 et seq.] (225 ILCS 235/3) [Added June 2000].

• Structure - for the purposes of the structural pest control regulations, any edifice, building or other constructed

entity including the contents therein, any patio or terrace connected thereto and the land on which it is situated, and including any portion of land within the given proprietorship which might constitute a potential harborage for pests which could affect the edifice or building or its contents, any portion of land upon which work has begun for the erection of an edifice, any vehicle used as a common carrier, any dock, wharf, railroad siding or refuse area (225 ILCS 235/3) [Added June 2000].

• Structural Pest Control - and includes the on-site identification of an infestation in, on or under a structure or

the use of any method or device or the application of any substance to prevent, repel, mitigate, curb, control or eradicate any pest in, on or under a structure or within a part of, or materials used in building, a structure; the use of any pesticide, including insecticides, fungicides and other wood treatment products, attractants, repellents, rodenticides, fumigants or mechanical devices for preventing, controlling, eradicating, identifying, mitigating, diminishing or curbing insects, vermin, rats, mice or other pests in, on or under a structure or within a part of, or materials used in building, a structure; vault fumigation and fumigation of box cars, trucks, ships, airplanes, docks, warehouses and common carriers or soliciting to perform any of the foregoing functions (225 ILCS 235/3) [Added June 2000].

• Supervision - for the purposes of the structural pest control regulations, the direction and management by

certified personnel of the activities of non-certified personnel in use and storage of general use or restricted pesticides (225 ILCS 235/3) [Added June 2000].

• Sub-Category - for the purposes of the structural pest control regulations, a specific area of pest control in which

a pest control technician may be separately certified as specified by this Act or by rule promulgated thereunder (225 ILCS 235/3) [Added June 2000].

• Turf - the upper stratum of soils bound by grass and plant roots into a thick mat (415 ILCS 65/2) [Added June

2000]. • Use - any activity covered by the pesticide label including but not limited to application of pesticide, mixing and

loading, storage of pesticides or pesticide containers, disposal of pesticides and pesticide containers and reentry into treated sites or areas (Illinois Pesticide Act para. 804).

Page 159: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-4 Pesticide Management

PESTICIDE MANAGEMENT GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: Missing Checklist Items PM.2.1.IL. Pesticide Applicators PM.5.1.IL. Pesticide Application

General PM.10.1.IL. through PM.10.5.IL. Equipment PM.15.1.IL. Other

Lawns and Golf Courses PM.35.1.IL. through PM.35.3.IL. Bird Control PM.35.4.IL.

Documentation PM.40.1.IL. and PM.40.2.IL. Storage/Mixing/Handling PM.45.1.IL. through PM.45.3.IL.

Page 160: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-5 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

PM.2. MISSING CHECKLIST ITEMS

PM.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 161: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-6 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

PM.5. PESTICIDE APPLICATORS

PM.5.1.IL. Personnel who apply restricted-use pesticides must be licensed (Illinois Pesticide Act, Para. 811 through 812).

Verify that no person uses or supervises the use of pesticides classified for restricted use without a license and certification issued from the Director.

(NOTE: Department of Defense (DoD) personnel must meet the licensing require-ments of the state.)

Page 162: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-7 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

PESTICIDE APPLICATION PM.10. GENERAL

PM.10.1.IL. Pesticide incidents must be reported (Title 8, Illinois Administrative Code, Section 250.200 (8 IAC 250.200)).

Verify that all pesticide incidents or misuse complaints are reported in writing to the Director at the time of occurrence or not later than 30 days after the incident or complaint or within 30 days of when damage or adverse effects are evident.

PM.10.2.IL. Specific pesti-cides must be used only with a permit (8 IAC 250.160).

Verify that the following pesticides are used only in accordance with a permit issued by the Director:

- Dichloro diphenyl trichlorethane (DDT) - Sodium fluoroacetate (Compound 1080) - Fluoroacetamide (Compound 1081).

PM.10.3.IL. Pesticide management must meet specific operational requirements for the use of pesticides (Illinois Pesticide Act, para. 814).

Verify that personnel who handle, apply, or use pesticides do not:

- apply known ineffective or improper pesticides - apply pesticides in a faulty, careless, or negligent manner - use or recommend for use a pesticide inconsistent with the labeling of the

pesticide - use or supervise the use of pesticides without qualifying as a certified

applicator or licensed operator - use fraud or misrepresentation in making application for, or renewal of, a

license or certification - distribute a pesticide not registered for use - aid or abet a person to use or allow a license, permit, or certification to be

used by another person - apply any pesticide container that does not have all required label

information securely affixed - apply any pesticide that is adulterated or misbranded - apply any pesticide that is hazardous to store or handle due to damage to the

container.

Verify that facility personnel do not handle, store, display, or use pesticides in such a manner as to endanger humans or the environment, to endanger food, feed, or other products that may be stored, displayed, or distributed with such pesticides.

Page 163: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-8 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that facility personnel do not use, dispose of, discard, or store pesticides or their containers in such a manner as to endanger human health or the environment or to pollute water supplies.

PM.10.4.IL. Structural pest control applicators must meet general safety requirements (77 IAC 830.800(d) through (f)) [Added June 2000].

(NOTE: This checklist item applies to persons/facilities engaged in structural pest control (see definitions).)

Verify that each licensee or registrant advises all service technicians within their employ of the hazards associated with the handling of pesticides, as well as the special hazards involved with those pesticides with which a technician might come into contact, and instructs those technicians in the appropriate precautions in order to avoid those hazards.

Verify that any necessary safety equipment as set forth in the pesticide labeling and this chapter are provided by each licensee or registrant.

Verify that no person applies any pesticide formulation as a liquid, aerosol, fog, mist, dust or powder in any area where food is exposed.

Verify that for all applications of pesticide formulations in food areas, the following conditions are met:

- prior to treatment, all exposed food and food contact surfaces are effectively protected against pesticide contamination

- people without appropriate respiratory protection are not allowed in the same room where the application of an aerosol, mist, fog, dust or powder has been sprayed into the air until the room has been ventilated according to label directions or, in their absence, manufacturer's recommendations

- any additional safety precautions or directions as detailed on the pesticide label or labeling are accomplished prior to treatment.

(NOTE: As an exception to the preceding requirements, there may be the application of an appropriately labeled liquid or aerosol pesticide applied as a crack and crevice treatment through a small hollow injection tube placed directly into the target site below the level of the exposed food or food contact surface, unless the pesticide label contains more restrictive directions.)

Verify that for the application of any liquid, aerosol, mist, fog, dust or powder pesticide formulation to patient areas or rooms of health care facilities (i.e., nursing homes, mental health facilities, hospitals, etc.):

- no patients are present in the areas or rooms - at the end of the pesticide application, the pest control technician posts a

legibly completed sign at all entrances to the treated room or area which warns unauthorized individuals to remain out of the treated area for the specified amount of time as determined by reviewing the pesticide label directions or, in their absence, by consulting the pesticide manufacturer

Page 164: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-9 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- the sign contains black letters on a yellow background - the pest control technician gives a copy of the following materials to the

person responsible for patient care in the treated areas: - a copy of the information contained on the signs - a copy of the label for each pesticide used - a Material Safety Data Sheet for each pesticide used - manufacturer's recommendations for re-entry times and procedures

when not addressed on the pesticide label - at the end of the treatment period, the pest control technician makes certain

by onsite inspection that the ventilation procedures have been initiated in the treated room or area in accordance with label directions or, in their absence, manufacturer's recommendations for the pesticides used in the room or area (in the event that ventilation times are not stated on the pesticide label and not provided by the manufacturer, the ventilation period will last for a minimum of 2 hr).

PM.10.5.IL. Structural pest control applicators must report (77 IAC 830.870) [Added June 2000].

(NOTE: This checklist item applies to persons/facilities engaged in structural pest control (see definitions).)

Verify that personnel notify the Department within one business day of becoming aware of any of the following incidents allegedly caused by the use of pesticides under their control:

- illness or death of humans, pets, or non-target wildlife - food or water contamination - any health threatening contamination of a structure or the environment

Verify that personnel take whatever steps are necessary (e.g. removing contaminated articles from the treatment site, cleaning up a spill according to label directions or manufacturer's recommendations, ventilating an area to eliminate odors from the application area, etc.) in order to abate any imminent health threat resulting from the use of pesticides under their control.

Page 165: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-10 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

PESTICIDE APPLICATION PM.15. EQUIPMENT

PM.15.1.IL. Service vehicles used to transport or store pesticides must meet safety requirements (77 IAC 830.840) [Added June 2000].

Verify that service vehicles used to transport and/or temporarily store pesticides are:

- locked at all times while unattended or not in a locked garage, and no pesticide product are left in an accessible manner in an unattended vehicle

- equipped with a restraining device to prevent pesticide containers from becoming damaged while in transit

- equipped with absorbent material such as absorptive clay, or similar material, capable of absorbing small spills and leaks

- equipped with protective clothing and equipment appropriate for the pesticides stored or transported in the vehicle

- equipped with a basic first aid kit which includes information regarding practical treatment for pesticide poisonings and emergency medical information including telephone numbers for poison control centers

- equipped with a pesticide label for each pesticide transported or temporarily stored in the service vehicle

- equipped with a complete change of clothing (including shoes) for use in the event that the pesticide applicator's garments are accidentally contaminated while using a pesticide.

Verify that clothing is stored in the vehicle so as to prevent pesticide contamination.

Page 166: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-11 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

PESTICIDE APPLICATION PM.35. OTHER

Lawns and Golf Courses (NOTE: Applicators must be certified and licensed by the Department under the Illinois Pesticide Act before they can apply lawn care products to lawns (including golf courses) (415 ILCS 65/4).)

PM.35.1.IL. Lawns must be marked after application of pesticides (Chapter 415, Illinois Compiled Statutes, Paragrah 65/3(a) (415 ILCS 65/3(a))) [Added June 2000].

Verify that, immediately following application of lawn care products to a lawn, other than a golf course, an applicator for hire places a lawn marker at the usual point or points of entry.

Verify that the lawn marker consists of a 4 in. by 5 in. sign, vertical or horizontal, attached to the upper portion of a dowel or other supporting device with the bottom of the marker extending no less than 12 in.above the turf.

Verify that the lawn marker is white, and lettering on the lawn marker is in a contrasting color.

Verify that the marker states on one side, in letters of not less than 3/8 in., the following: "LAWN CARE APPLICATION - STAY OFF GRASS UNTIL DRY - FOR MORE INFORMATION CONTACT: (insert here the name and business telephone number of the applicator for hire)."

Verify that the lawn marker is removed and discarded only by the property owner or resident, or such other person authorized by the property owner or resident, and only on the day following the application (or later).

PM.35.2.IL. Golf courses must be posted with placards notifying users or visitors of pesticide use (415 ILCS 65/3(b)) [Added June 2000].

Verify that each golf course posts in a conspicuous place or places an all-weather poster or placard stating to users of or visitors to the golf course that from time to time plant protectants are in use, and additionally stating that if any questions or concerns arise, the golf course superintendent or his designee should be contacted to supply further information.

Verify that the poster or placard is prominently displayed in the pro shop, locker rooms and first tee at each golf course.

Verify that the poster or placard is a minimum size of 8 1/2 by 11 in., and the lettering is not less than 1/2 in.

Page 167: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-12 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that the poster or placard reads: "PLANT PROTECTANTS ARE PERIODICALLY APPLIED TO THIS GOLF COURSE. IF DESIRED, YOU MAY CONTACT YOUR GOLF COURSE SUPERINTENDENT FOR FURTHER INFORMATION."

PM.35.3.IL. Wash water and rinsate from pesticide application vehicles and equipment must be collected (415 ILCS 65/5) [Added June 2000].

Verify that all washing or rinsing of pesticide residues from vehicles, application equipment, mixing equipment, floors or other items used for the storage, handling, preparation for use, transport, or application of pesticides to lawns is performed at designated wash areas.

Verify that a lawn care containment permit, issued by the Department, is obtained prior to the operation of the wash water containment area.

Verify that a wash water containment areas is in use at any facility (see definitions), and no wash water or rinsates are released into the environment.

Verify that wash water containment areas are constructed of concrete, asphalt or other impervious materials which include, but are not limited to, polyethylene containment pans and synthetic membrane liners.

Verify that wash water containment areas are designed to capture spills, wash waters and rinsates generated in servicing vehicles and triple rinsing pesticide containers and prevent the release of such spills, wash waters or rinsates to the environment.

(NOTE: Wash waters and rinsates captured in the wash area may be either reused as makeup water for dilution of pesticides in preparation of application, or disposed in accordance with applicable local, State and federal regulations.)

(NOTE: These requirements do not apply to situations constituting an emergency where washing or rinsing of pesticide residues from equipment or other items is necessary to prevent imminent harm to human health or the environment. )

(NOTE: These requirements do not apply to persons subject to the containment requirements of the Illinois Pesticide Act [415 ILCS 60/1 et seq.] or the Illinois Fertilizer Act of 1961 [505 ILCS 80/1 et seq.] and any rules or regulations adopted thereunder.)

Bird Control

PM.35.4.IL. The use of pesticides for bird control must be permitted (77 IAC

Verify that there is no use of restricted or general use avicides for the control of any number of pigeons or starlings, or house sparrows in flocks over 500, or any number of other birds, unless the avicide is applied by a commercial structural pest

Page 168: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-13 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

830.880(a), (b) and (d)) [Added June 2000].

control licensee or by a non-commercial structural pest control location having an Avicide Permit.

(NOTE: The use of avicides for pest bird control by a non-commercial structural pest control location engaged in the production, protection, care, storage, or transportation of agricultural commodities is exempt from this requirement, as are uses already regulated by the Illinois Pesticide Act.)

(NOTE: This requirement does not apply to the use of 20,25 diazacholestenol, restricted uses of 4-aminopyridine, and restricted uses of 3-chloro-p-toluidine hydrochloride.)

Verify that restricted avicides are used, or their use supervised on-site, by a person certified in the sub-category of bird control.

Verify that a separate Avicide Permit (Form IL #482-0722) is obtained for each structure for which bird control is needed.

(NOTE: Multiple structures on the same or contiguous pieces of property require only one Avicide Permit.)

Page 169: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-14 Pesticide Management

Page 170: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-15 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

PESTICIDE APPLICATION PM.40. DOCUMENTATION

PM.40.1.IL. Certified commercial applicators and operators must keep records of applications of restricted-use pesticides (8 IAC 250.150).

Verify that certified commercial applicators and operators keep a record of all restricted pesticide usage for 2 yr that includes, but is not limited to, the following for each individual use of a restricted use pesticide:

- name of the chemical - USEPA registration number - amount of chemical concentration per unit treated (e.g., pounds or ounces per

acre) - date of application - use site(s).

PM.40.2.IL. Persons engaged in structural pest control must meet specific record keeping requirements (77 IAC 830.820) [Added June 2000].

(NOTE: This checklist item applies to persons/facilities engaged in structural pest control (see definitions).)

Verify that each non-commercial structural pest control business location keeps records of all restricted pesticide applications at the location for a minimum of 2 yr.

Verify that the certified technician responsible for using pesticides, or overseeing the use of pesticides by non-certified personnel, provides written verification (i.e. signature and certification number) of review for all pesticide records.

Verify that records of restricted pesticide usage are kept separate from those pertaining to general pesticide usage, and that both include the following:

- name and address of customer or site of application - name of technician applying the pesticide - date of application - target pest or purpose for the application - pesticide use recorded in the following manner:

- brand or common name - USEPA Registration Number - percent active ingredient in the finished product - an estimate of the amount of finished product used.

Verify that all records (except those for the week prior to the inspection) are kept

Page 171: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-16 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

at the business location and are available for inspection by the Department.

Page 172: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-17 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

PM.45. STORAGE/MIXING/ HANDLING

PM.45.1.IL. Persons missing or handling pesticides must comply with general safety requirements (77 IAC 830.800(a) through (c)) [Added June 2000].

(NOTE: This checklist item applies to persons/facilities engaged in structural pest control (see definitions).)

Verify that no person mixes pesticides in any container using water from any water supply which is not adequately protected against backsiphonage by a minimum air gap of 2 in. between the water discharge outlet and the flood rim of the container.

(NOTE: When the pesticide application equipment is manufactured to draw water through a direct connection with the water supply, a backflow preventer or vacuum breaker device approved by the Illinois Plumbing Code will be installed between the water supply and the pesticide application equipment.)

Verify that no person mixes or operates equipment for the application of pesticides, including such auxiliary equipment as hoses and metering devices, in such condition or in such manner as to create a hazard from leaking, spilling, dripping, backflow, vapors or drift.

Verify that no pesticide application equipment is used which is faulty in any fashion or which has not been cleaned in a manner to prevent the misuse of a pesticide.

PM.45.2.IL. Pesticide storage must meet specific security requirements (77 IAC 830.830) [Added June 2000].

(NOTE: This checklist item applies to persons/facilities engaged in structural pest control (see definitions).)

Verify that all pesticides utilized by commercial/non-commercial pest control locations are stored in an area which will hold normal stocks in an orderly fashion.

Verify that the pesticide storage area is dry, cool, and constructed so as to protect pesticides from direct sunlight exposure or adverse temperature extremes.

Verify that the temperature in the pesticide storage area is controlled according to the pesticide manufacturer's recommendations or label directions.

Verify that the pesticide storage area is located in an area not accessible to unauthorized individuals.

Verify that the pesticide storage area is equipped with a door which is locked when unattended.

Verify that the door or entrance to the storage area has a sign which warns

Page 173: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-18 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

individuals that pesticides are stored inside.

Verify that only those individuals with training in pesticide use and handling are allowed access to the storage area.

Verify that the pesticide storage area is ventilated to the outside so as to prevent the build-up of chemical odors, gases or vapors in the storage area, as well as any structure housing the storage area.

Verify that ventilation accomplished through mechanical means is operated in such a manner so as to prevent the discharged air or vaporized fumes from being introduced into an area frequented by the public.

Verify that the pesticide storage area is equipped with lighting to allow pesticide labels to be clearly read.

Verify that the pesticide storage area is equipped with an operational fire extinguisher which is appropriate for the pesticides store therein.

Verify that the pesticide storage area is equipped with washing facilities in the room, or nearby, which include soap or detergent, water, and disposable towels.

Verify that the pesticide storage area is equipped with absorbent material such as absorptive clay, or similar material, capable of absorbing small spills and leaks.

Verify that any safety equipment required by labeling or this regulation is available to workers for use in this area, and is not stored within the storage area.

Verify that the pesticide storage area is equipped with emergency medical information including telephone numbers for poison control centers.

Verify that the pesticide storage area is equipped with a label file for those pesticides stored.

PM.45.3.IL. Pesticide storage must comply with specific supplementary practices (77 IAC 830.850) [Added June 2000].

(NOTE: This checklist item applies to persons/facilities engaged in structural pest control (see definitions).)

Verify that all pesticides utilized by the owners, operators, or employees of non-commercial pest control business locations are stored according to labeling instructions and the following supplementary practices:

- all pesticides are stored in closed, original containers, free from severe corrosion (e.g., rusted so as to affect the integrity of the containers; leaking) and pesticide contamination

- containers, except 55 gallon drums, are be stored on pallets, racks, shelves, or cabinets with the label plainly visible

- lost or damaged labels are replaced with an approved sample label obtained

Page 174: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-19 Pesticide Management

COMPLIANCE CATEGORY: PESTICIDE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

from the pesticide manufacturer or distributor, and fastened to the container - damaged containers other than fumigants are replaced with identically labeled

containers or, if not available, a properly labeled service container for temporary storage or transport.

(NOTE: These practices are intended to supplement labeling instructions. Where there is a discrepancy between labeling instructions and the following practices, the more stringent instructions prevail.)

Verify that service containers are only utilized to temporarily store or transport a pesticide concentrate or registered ready-to-use product, and the service container bears a legible label which includes the following information:

- the name, address and telephone number of the commercial or non-commercial location using the product

- the product name and USEPA registration number - the name and percentage of active ingredients - the signal word for the registered label - mixing instructions as well as the working dilution (if applicable) - the phrase "KEEP OUT OF REACH OF CHILDREN" - a Statement of Practical Treatment.

Verify that a service container is closed when not in use, clean so as to prevent the misuse of a pesticide, and non-leaking.

Verify that pesticides used for structural pest control are segregated from all other pesticides.

Verify that fumigants are not stored within any human dwelling or attached structure.

Verify that restricted use pesticides are stored in the locked storage area segregated from all other pesticides, identified by a placard stating "RESTRICTED USE PESTICIDES -- Authorized Use Only" in black letters on a yellow background.

Verify that non-restricted pesticides with a signal word "DANGER" on the label are kept segregated from other pesticides.

Verify that pesticides which cannot be used because of suspension by USEPA or regulatory action by the Illinois Department of Agriculture and/or this Department are marked as such and segregated from other stocks so that they are not used.

Verify that no pesticide is stored in any food or beverage container or in the same room, or passenger area of a service vehicle, where food, eating utensils, beverages, tobacco products or household goods are stored.

Page 175: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

7-20 Pesticide Management

Page 176: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Petroleum, Oil, and Lubricant (POL) Management

8-1

SECTION 8

PETROLEUM, OIL, AND LUBRICANT (POL) MANAGEMENT

Illinois Supplement, June 2000 This section covers the Illinois requirements for POL Management and is intended to supplement the U.S. TEAM Guide. Although Illinois has not formally adopted the Federal used oil regulations (codified at Title 40 of the Code of Federal Regulations, Part 279), the Illinois regulations are substantially the same as the Federal regulations. Illinois has no other regulations that are applicable under this Section. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Page 177: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Petroleum, Oil, and Lubricant (POL) Management

8-2

PETROLEUM, OIL, AND LUBRICANT (POL) MANAGEMENT GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: Missing Checklist Items PO.2.1.IL.

Page 178: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

Petroleum, Oil, and Lubricant (POL) Management

8-3

COMPLIANCE CATEGORY: PETROLEUM, OIL, AND LUBRICANT (POL) MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

PO.2. MISSING CHECKLIST ITEMS

PO.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 179: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-1 Solid Waste Management

SECTION 9

SOLID WASTE MANAGEMENT

Illinois Supplement, June 2000 This section covers the Illinois requirements for Solid Waste Management and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Definitions

• Abandonment - the failure to initiate closure within 30 days after receipt of the final volume of waste (Title 35, Illinois Administrative Code, Section 807.104 (35 IAC 807.104)).

• Admixtures - chemicals added to earth materials to improve for a specific application the physical or chemical

properties of the earth materials. Admixtures include, but are not limited to, lime, cement, bentonite, and sodium silicate (35 IAC 810.103).

• Agency - the Illinois Environmental Protection Agency established by the Environmental Protection Act (35

IAC 810.103). • Agronomic Rates - the application of not more than 20 tons per acre per year, except that the Agency may allow

a higher rate for individual sites where the owner or operator has demonstrated to the Agency that the site's soil characteristics or crop needs require a higher rate (35 IAC 830.102).

• Aisle - an accessible clear space between storage piles or groups of piles suitable for housekeeping operations,

visual inspection of piling areas, and initial fire fighting operations (35 IAC 848.104). • Altered Tire - a used tire which has been altered so that it is no longer capable of holding accumulations of water

including, but not limited to, used tires that have been shredded, chopped, drilled with holes sufficient to assure drainage, slit longitudinally, and staked so as not to collect water, or wholly or partially filled with cement or other material to prevent the accumulation of water (35 IAC 848.104).

• Aquifer - saturated (with groundwater) soils and geologic materials which are sufficiently permeable to readily

yield economically useful quantities of water to wells, springs, or streams under ordinary hydraulic gradients and whose boundaries can be identified and mapped from hydrogeologic data (35 IAC 810.103).

• Bad Load - a load of material that would, if accepted, cause or contribute to a violation of the Act, even it

managed in accordance with these regulations and any facility permit conditions (35 IAC 830.102). • Board - the Illinois Pollution Control Board (35 IAC 830.102). • Borrow Area - an area from which earthen material is excavated for the purpose of constructing daily cover,

final cover, a liner, a gas venting system, roadways or berms (35 IAC 810.103). • Bulking Agent - a material used to increase porosity, to improve aeration, or to absorb moisture from

decomposing waste (35 IAC 830.102). • Cell - compacted refuse completely enclosed by cover material (35 IAC 807.104).

Page 180: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-2 Solid Waste Management

• Chemical Treatment - the treatment of potentially infectious medical waste (PIMW) in a unit that uses disinfectants or chemicals as the primary means to eliminate the infectious potential of the waste. Examples of chemical treatment are ethylene oxide, chlorine, and ozone (35 IAC 1420.102).

• Chemical Waste - a nonputrescible solid whose characteristics are such that any contaminated leachate is

expected to be formed through chemical or physical processes, rather than biological processes, and no gas is expected to be formed as a result (35 IAC 810.103).

• Commercial Activity - any activity involving the transfer of money (35 IAC 830.102). • Compaction - the reduction of volume of material under load. Compaction is a “treatment” (35 IAC 807.104). • Compost - the humus-like product of the process of composting waste, which may be used as a soil conditioner

(35 IAC 830.102). • Composting - the biological treatment process by which microorganisms decompose the organic fraction of the

waste, producing compost. Land application is not composting (35 IAC 830.102). • Composting Area - the area of a composting facility in which waste, composting material or undistributed end-

product compost is unloaded, stored, staged, stockpiled, treated or otherwise managed (35 IAC 830.102). • Composting Material - solid wastes that are in the process of being composted (35 IAC 830.102). • Composting Operation - an enterprise engaged in the production and distribution of end-product compost (35

IAC 830.102). • Contained Composting Process - a method of producing compost in which the composting material is confined

or contained in a vessel or structure which both protects the material from the elements and controls the moisture and air flow (35 IAC 830.102).

• Container (in relation to PIMW) - a receptacle that does not contain PIMW (35 IAC 1420.102). • Contaminated Leachate - any leachate whose constituent violate the standards of 35 IAC 811.202 which states

that leachate shall be considered contaminated if it contains concentrations of constituents greater than the public and food processing water supply standards 35 IAC 302.301, 302.304, and 302.305. The operator shall determine whether the leachate from the waste is contaminated by analyzing it for constituents for which a numerical standard has been established (35 IAC 810.103).

1. a representative sample of leachate extracted from the waste by a laboratory procedure may be used to model the expected constituents concentration of the leachate. The laboratory test shall meet the following standards:

a. the procedure shall be designed to closely reproduce expected field conditions b. the test shall utilize an extraction fluid representative of the physical and chemical characteristics of

the liquid expected to infiltrate through the waste 2. actual samples of leachate from an existing solid waste disposal unit or a test fill may be utilized under the

following conditions: a. the waste in the existing unit is similar to the waste expected to be disposed b. the conditions under which the leachate was formed are similar to those expected to be encountered,

and c. leachate is sampled so as to be representative of undiluted and unattenuated leachate emanating from

the unit. • Controlled Landfill - any landfill at which collection and control systems are required as a result of the NMOC

emission rate. The landfill is considered controlled at the time application for a construction permit for a collection and control system is submitted to the Agency (35 IAC 220.110) [Added May 1999].

Page 181: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-3 Solid Waste Management

• Converted Tire - a used tire which has been manufactured into a usable commodity other than a tire (35 IAC

848.104). • Cover Material - soil or other material that is used to cover compacted solid waste in a sanitary landfill and that

is free of objects that would hinder compaction and free of content that would be conducive to vector harborage, feeding, or breeding (35 IAC 807.104).

• Covered Tire - a used tire located in a building, vehicle, or facility with a roof extending over the tire, or

securely located under a material so as to preclude exposure to precipitation (35 IAC 848.104). • Declassified Waste - a waste which has been determined, pursuant to 35 IAC 808.245 to not be a special waste

(35 IAC 808.110). • Design Capacity - the maximum amount of solid waste a landfill can accept, as indicated in terms of volume or

mass, as specified in the permit(s) issued pursuant to Section 21(d) of the Act for the source plus any in-place waste not accounted for in the permit(s); if no design capacity is specified in a permit, then the design capacity shall be calculated using good engineering practices; or if the landfill is closed pursuant to the applicable regulations in 35 Ill. Adm. Code. Subtitle G, the actual capacity specified in the closure plan. If the owner or operator chooses to convert the design capacity from volume to mass or from mass to volume to demonstrate its design capacity is less than 2.5 million Mg or 2.5 million m3, the calculation must include a site-specific density, which must be recalculated annually (35 IAC 220.110) [Added May 1999].

• Design Period - that length of time determined by the sum of the operating life of the solid waste landfill facility

plus the postclosure care period necessary to stabilize the waste in the units (35 IAC 810.103). • Designated Use Compost - end-product compost which does not meet the standards set forth in Section 830.503

of this Part (35 IAC 830.102). • Development - construction or installation of a unit (35 IAC 807.104). • Dewar Flask - an insulated container used especially to store liquefied gases, having a double wall, an evacuated

space between the walls and silvered surfaces (35 IAC 830.102). • Discharge (in relation to PIMW) - the accidental or intentional spilling, leaking, pumping, pouring, emitting,

emptying or dumping of waste into or on any land or water, not including the normal loading or unloading of PIMW from a vehicle (35 IAC 1420.102).

• Disposal - the discharge, deposit, injection, dumping, spilling, leaking, or placing of any waste into or on any

land or water or into any well so that such waste or any constituent thereof may enter the environment or be emitted into the air or discharged into any waters, including groundwater. As used in Part 807, “disposal” includes methods of storage or treatment in which there is no certain plan to remove wastes or waste residues from the storage or treatment unit to another unit for ultimate disposal (35 IAC 807.104).

• Disposal of Tires - the placement of used tires into or on any land or water except as an integral part of

systematic reuse or conversion in the regular course of business (35 IAC 848.104). • Disturbed Areas - those areas within a facility that have been physically altered during waste disposal operations

or during the construction of any part of the facility (35 IAC 810.103). • Documentation - items, in any tangible form, whether directly legible or legible with the aid of any machine or

device including, but not limited to, affidavits, certificates, deeds, leases, contracts or other binding agreements, licenses, permits, photographs, audio or video recordings, maps, geographic surveys, chemical and mathematical formulas or equations, mathematical and statistical calculations and assumptions, research papers, technical

Page 182: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-4 Solid Waste Management

reports, technical designs and design drawings, stocks, bonds and financial records, that are used to support facts or hypotheses (35 IAC 810.103).

• Earth Liners - structures constructed from naturally occurring soil material that has been compacted to achieve a

low permeability (35 IAC 810.103). • End-product Compost - organic material that has been processed to maturity and classified as general use

compost or designated use compost in accordance with this Part (35 IAC 830.102). • Existing Facility - a facility or unit which is not defined as a new facility or new unit (35 IAC 810.103). • Facility - a site and all equipment and fixtures on a site used to treat, store, or dispose of solid or special wastes.

A facility consists of an entire solid or special waste treatment, storage, or disposal operation. All structures used in connection with or to facilitate the waste disposal operation shall be considered a part of the facility. A facility may include, but is not limited to, one or more solid waste disposal units, buildings, treatment systems, processing and storage operations, and monitoring stations. As used in Part 807, facility means the same thing as “unit' (35 IAC 807.104).

• Field Capacity - that maximum moisture content of a waste, under field conditions of temperature and pressure,

above which moisture is released by gravity drainage (35 IAC 810.103). • Final Volume of Waste - the last quantity of waste received by the operator at the site. A quantity of waste is

assumed to be the final volume if the operator receives no additional waste within 30 days after receiving the quantity, unless the operator demonstrates that the operator expects additional waste. Waste arriving at the site for disposal in a manner which is not controlled by the operator does not affect the determination of when the final volume of waste was received by the operator (35 IAC 807.104).

• Garbage - the waste resulting from the handling, processing, preparation, cooking, and consumption of food and

wastes from the handling, processing, storage, and sale of produce (35 IAC 809.103). • Garden Compost Operation - an operation which: (35 IAC 830.102)

1. has no more than 25 cubic yards of landscape waste, composting material or end-product compost on-site at any one time, and

2. is not engaging in commercial activity. • Gas Collection System - a system of wells, trenches, pipes and other related ancillary structures such as

manholes, compressor housing, and monitoring installations that collects and transports the gas produced in a putrescible waste disposal unit to one ore more gas processing points. The flow of gas through such a system may be produced by naturally occurring gas pressure gradients or may be aided by an induced draft generated by mechanical means (35 IAC 810.103).

• Gas Condensate - the liquid formed as a landfill gas is cooled or compressed (35 IAC 810.103). • Gas Mover Equipment - the equipment (i.e., fan, blower, compressor) used to transport landfill gas through the

header system (35 IAC 220.110) [Added May 1999]. • Gas Venting System - a system of wells, trenches, pipes, and other related structures that vents the gas produced

in a putrescible waste disposal unit to the atmosphere (35 IAC 810.103). • General Use Compost - end-product compost which meets the standards set forth in Section 830.503 of this Part

(35 IAC 830.102). • Groundwater - water occurring in the zone of saturation in any aquifer or soil (35 IAC 807.104).

Page 183: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-5 Solid Waste Management

• Hydraulic Barriers - structures designed to prevent or control the seepage of water. Hydraulic barriers include, but are not limited to, cutoff walls, slurry walls, grout curtains, and liners (35 IAC 810.103).

• Inactive Landfill - a landfill in which solid waste is no longer being placed, and that is no longer permitted to

accept waste under Section 21 of the Act or has a federally enforceable permit condition prohibiting the acceptance of additional waste. If an inactive landfill is subsequently permitted to accept additional waste and additional solid waste is placed in the landfill, the landfill is no longer inactive (35 IAC 220.110) [Added May 1999].

• Indefinite Storage - treatment or storage in such a manner that a person would face technical difficulties or high

costs in removing the wastes or waste residues from the treatment or storage unit to a disposal unit so that it may become necessary to close the treatment or storage unit as a disposal unit. A treatment or storage unit in which wastes or waste residues remain for more than 1 yr is assumed to be indefinite storage unless the operator demonstrates that it will be technically feasible and economically reasonable to remove the waste for ultimate disposal prior to or upon closure (35 IAC 807.104).

• Industrial Process Waste - any liquid, solid, semi-solid, or gaseous waste generated as a direct or indirect result

of the manufacture of a product or the performance of a service which poses a present or potential threat to human health or to the environment or with inherent properties which make the disposal of such waste in a landfill difficult to manage by normal means. Industrial Process Waste includes, but is not limited to, spent pickling liquors, cutting oils, chemical catalysts, distillation bottoms, etching acids, equipment cleanings, paint sludges, incinerator ashes, core sands, metallic dust sweepings, asbestos dust, hospital pathological wastes, and off-specification, contaminated or recalled wholesale or retail products. Specifically excluded are uncontaminated packaging materials, uncontaminated machinery components, general household waste, landscape waste and construction or demolition debris (35 IAC 809.103).

• Inert Waste - any solid waste that will not decompose biologically, burn, serve as food for vectors, form a gas,

cause an odor, or form a contaminated leachate. Such inert wastes shall include only non-biodegradable and non-putrescible solid wastes. Inert wastes may include, but are not limited to, bricks, masonry, and concrete (cured for 60 days or more) (35 IAC 810.103).

• Land Application - the spreading of waste, at an agronomic rate, as a soil amendment to improve soil structure

and crop productivity (35 IAC 830.102). • Land Application Unit - an area where wastes are agronomically spread over or disked into land or otherwise

applied so as to become incorporated into the soil surface (35 IAC 810.103). • Landfill - a unit or part of a facility in or on which waste is placed and accumulated over time for disposal, and

which is not a land application unit, a surface impoundment, or an underground injection well. For the purposes of 35 IAC 811 through 815, landfills include waste piles (35 IAC 810.103).

• Landscape Waste - all accumulations of grass or shrubbery cuttings, leaves, tree limbs and other materials

accumulated as the result of the care of lawns, shrubbery, vines and trees (35 IAC 830.102). • Landscape Waste Compost Facility - an entire landscape waste composting operation, with the exception of a

garden compost operation (35 IAC 830.102). • Landscape Waste Leachate - a liquid containing any of the following: waste constituents originating in

landscape waste; landscape waste composting material; additives; and end-product compost (35 IAC 830.102). • Leachate - liquid containing materials removed from solid waste (35 IAC 807.104). • Lift - an accumulation of refuse which is compacted into a cell and over which compacted cover is placed (35

IAC 807.104).

Page 184: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-6 Solid Waste Management

• Malodor - an odor caused by one or more contaminant emissions into the atmosphere from a facility that is in

sufficient quantities and of such characteristics and duration as to be described as malodorous and which may be injurious to human, plant, or animal life, to health, or to property, or reasonably interfere with the enjoyment of life or property (35 IAC 810.103).

• Manifest - the form provided or prescribed by the Agency and used for identifying name, quantity, and the

origin, routing, and destination of special waste during its transportation from the point of generation to the point of disposal, treatment, or storage (35 IAC 809.103).

• Maturity - a state which is characteristically; generally dark in color; humus-like; crumbly in texture; not

objectionable in odor; resembling rich topsoil; and bearing little resemblance in physical form to the waste from which it is derived (35 IAC 830.102).

• Modification - any physical change, or change in the method of operation, of a solid waste management unit. For

purposes of permits issued pursuant to Part 807, the Agency may specify conditions under which a solid waste management unit may be operated without causing a modification as herein defined (35 IAC 807.104).

• Municipal Solid Waste (MSW) Landfill - an entire disposal facility or landfill in a contiguous geographical space

where household waste is placed in or on land. An MSW landfill may also receive other types of RCRA Subtitle D wastes such as commercial solid waste, nonhazardous sludge, conditionally exempt small quantity generator waste, and industrial solid waste. Portions of an MSW landfill may be separated by access roads. An MSW landfill may be publicly or privately owned or operated (35 IAC 220.110) [Added May 1999].

• Municipal Solid Waste (MSW) Landfill Emissions - gas generated by decomposition of organic waste deposited

in an MSW landfill or derived from the evolution of organic compounds in the waste (35 IAC 220.110) [Added May 1999].

• National Pollutant Discharge Elimination System (NPDES) - the program for issuing, modifying, revoking and

reissuing, terminating, monitoring, and enforcing permits and imposing and enforcing pretreatment requirements under the Clean Water Act (35 IAC 810.103).

• New Facility or New Unit - a solid waste landfill facility or a unit at a facility, if one or more of the following

conditions apply (35 IAC 810.103): 1. it is a landfill or unit exempt from permit requirements pursuant to Section 21(d) of the Act that has not yet

accepted any waste as of the 18 September 1990. 2. it is a landfill or unit not exempt from permit requirements pursuant to Section 21(d) of the Act that has no

development or operating permit issued by the Agency pursuant to 35 IAC 807 as of 18 September 1990. 3. is a landfill with a unit whose maximum design capacity or lateral extent is increased after 18 September

1990. • New Tire - a tire which has never been placed on a vehicle wheel rim (35 IAC 848.104). • Non-compostable Material - items not subject to microbial decomposition under conditions used to compost

waste (35 IAC 830.102). • Nonhazardous Special Waste - any special waste, as defined in this Section, that has not been identified, by

characteristics or listing, as hazardous pursuant to Section 3001 of the Resource Conservation and Recovery Act of 1976 (42 U.S.C. 6901 et seq.) or pursuant to Board regulations (35 IAC 809.103) [Added June 2000].

• Nonhazardous Special Waste Hauling Vehicle - any self-propelled motor vehicle, except a truck tractor without

a trailer, used to transport nonhazardous special waste in bulk or packages, tanks, or other containers (35 IAC 809.103) [Added June 2000].

Page 185: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-7 Solid Waste Management

• Nonhazardous Special Waste Transporter - any person who transports nonhazardous special waste (35 IAC 809.103) [Added June 2000].

• Nonmethane Organic Compounds (NMOC) - nonmethane organic compounds, as measured according to the

provisions of Section 220.260 of this Part (35 IAC 220.110) [Added May 1999]. • 100 Yr Flood Plain - any land area which is subject to a 1 percent or greater chance of flooding in a given year

from any source (35 IAC 810.103). • 100 Yr, 24-H Precipitation Event - a precipitation event of 24-h duration with a probable recurrence interval of

once in 100 yr (35 IAC 810.103). • Off-site - any site that is not "on-site" (35 IAC 809.103) [Added June 2000]. • On-farm Landscape Waste Compost Facility - a landscape compost facility which satisfies all of the criteria set

forth in Section 830.106 (35 IAC 830.102). • On-site - (for the purpose of transporting hazardous waste) on the same or geographically contiguous property

that may be divided by public or private rights-of-way, provided that entrance and exit between the properties is at a cross-roads intersection, and access is by crossing, as opposed to going along, the rights-of-way. Non-contiguous properties owned by the same person but connected by a right-of-way that the person controls, and to which the public does not have access, is also considered on-site property (35 IAC 809.103) [Added June 2000].

• On-site - on the same or geographically contiguous property which may be divided by public or private right-of-

way, provided the entrance and exit between the properties is at a crossroads intersection and access is by crossing as opposed to going along the right-of-way. Noncontiguous properties owned by the same person but connected by a right-of-way which the owner controls and to which the public does not have access are also considered on-site property (35 IAC 830.102).

• On-site Commercial Facility - a landscape waste compost facility at which the landscape waste composted is

generated only on-site and the end-product is offered for off-site sale or use (35 IAC 830.102). • On-site Facility - a landscape waste compost facility at which the landscape waste composted is generated only

on-site and the end-product is not offered for off-site sale or use (35 IAC 830.102). • Open Composting Process - a method of producing compost without protecting the compost from weather

conditions (35 IAC 830.102). • Open Dumping - the consolidation of refuse from one or more sources at a disposal site that does not fulfill the

requirements of a sanitary landfill (Chapter 415 Illinois Consolidated Statutes (ILCS), Section 5/3.24) [Added May 1998].

• Operator - a person who conducts a waste treatment, waste storage, or waste disposal operation (35 IAC

810.103). • Oversized PIMW - a single waste item that is too large to be placed into a 33 gal bag or container (35 IAC

1420.102). • Owner - a person who has an interest, directly or indirectly, in land, including a leasehold interest, on which a

person conducts a waste treatment, waste storage, or waste disposal operation. The owner is the operator if there is no other person who is conducting a waste treatment, waste storage, or waste disposal operation (35 IAC 807.104) (35 IAC 810.103).

• Package (in relation to PIMW) - a receptacle that contains PIMW (35 IAC 1420.102).

Page 186: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-8 Solid Waste Management

• Permeability - the capability of material to pass a fluid (35 IAC 807.104). • Permitted Disposal Site - a sanitary landfill or other type of disposal site including, but not limited to, a deep

well, a pit, a pond, a lagoon, or an impoundment which has a current, valid operating permit issued by the Agency and a supplemental permit issued by the Agency specifically permitting the site to accept a special waste tendered for disposal (35 IAC 809.103) [Revised June 2000].

• Permitted Storage Site - any site used for the interim containment of special waste prior to disposal or treatment

which has a current, valid operating permit issued by the Agency and a supplemental permit issued by the Agency specifically permitting the site to accept a special waste tendered for disposal (35 IAC 809.103) [Revised June 2000].

• Permitted Treatment Site - any site used to change the physical, chemical, or biological character or composition

of any special waste including, but not limited to, a processing center, a reclamation facility, or a recycling center which has a current, valid operating permit issued by the Agency and a supplemental permit issued by the Agency specifically permitting the site to accept a special waste tendered for disposal (35 IAC 809.103) [Revised June 2000].

• Person - any individual, partnership, co-partnership, firm, company, corporation, association, joint stock

company, trust, estate, political subdivision, state agency, or any other legal entity, or their legal representative, agent or assignee (35 IAC 810.103).

• PIMW - See Potentially Infectious Medical Waste. • Pollution Control Waste - any liquid, solid, semi-solid, or gaseous waste generated as a direct or indirect result

of the removal of contaminant from the air, water, or land, and which pose a present or potential threat to human health or to the environment or with inherent properties which make the disposal of such waste in a landfill difficult to manage by normal means. Pollution control waste includes, but is not limited to, water and wastewater treatment plant sludges, baghouse dusts, scrubber sludges and chemical spill cleanings (35 IAC 809.103).

• Potentially Infectious Medical Waste (PIMW) - the following types of waste generated in connection with the

diagnosis, treatment (i.e., provision of medical services) or immunization of human beings or animals; research pertaining to the provision of medical services; or the provision of testing of biologicals (35 IAC 1420.102):

1. cultures and stocks including, but not be limited to, cultures and stocks of agents infectious to humans, and associated biologicals; cultures from medical or pathological laboratories; cultures and stocks of infectious agents from research and industrial laboratories; wastes from the production of biologicals; discarded live or attenuated vaccines; or culture dishes and devices used to transfer, inoculate, or mix cultures

2. human pathological wastes including, tissue, organs, and body parts (except teeth and the contiguous structures of bone and gum), body fluids that are removed during surgery, autopsy, or other medical procedures; or specimens of body fluids and their containers

3. human blood and blood products including, discarded human blood, blood components (e.g. serums and plasma), or saturated material containing free flowing blood or blood components

4. used sharps including, but not limited to, discarded sharps used in animal or human patient care, medical research, or clinical or pharmaceutical laboratories; hypodermic, intravenous, or other medical needles; hypodermic or intravenous syringes; pasteur pipettes; scalpel blades; or blood vials, broken or unbroken glass (including slides and cover slips) in contact with infectious agents.

5. animal waste including, discarded materials such as carcasses, body parts, body fluids, blood, or bedding originating from animals inoculated during research, production of biologicals, or pharmaceuticals testing with agents infectious to humans

6. isolation waste including, discarded material contaminated with excretions, exudates, and secretions from humans that are isolated to protect others from highly communicable diseases

Page 187: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-9 Solid Waste Management

7. unused sharps including, but not limited to, hypodermic, intravenous, or other needles, hypodermic or intravenous syringes; or scalpel blades

(NOTE: PIMW does not include waste generated as household waste, waste (except for sharps) for which the infectious potential has been eliminated by treatment, or sharps which are rendered unrecognizable by treatment or which have been treated to eliminate the infectious potential.)

• Processing - the altering, converting, or reprocessing of used or waste tires (35 IAC 848.104). • Professional Engineer - an engineer registered to practice engineering in the State of Illinois (35 IAC 807.104). • Professional Land Surveyor - a person who has received a certificate of registration and a seal pursuant to The

Land Surveyors Act (35 IAC 810.103). • Putrescence (in relation to PIMW) - the partial decomposition of organic matter by microorganisms so as to

cause malodors, gases, or other offensive conditions, or that are capable of providing food for vectors (35 IAC 1420.102).

• Putrescible Waste - a solid waste that contains organic matter capable of being decomposed by microorganisms

so as to cause a malodor, gases, or other offensive conditions, or which is capable of providing food for birds and vectors. Putrescible wastes may form a contaminated leachate from microbiological degradation, chemical processes, and physical processes. Putrescible waste includes, but is not limited to, garbage, offal, dead animals, general household waste, and commercial waste. All solid wastes which do not meet the definitions of inert or chemical wastes shall be considered putrescible wastes (35 IAC 810.103).

• Recyclable Tire - a used tire which is free of permanent physical damage and maintains sufficient tread depth to

allow its use through resale or repairing (Section 54.06(a) of the Act) (35 IAC 848.104) [Added May 1999]. • Refuse - waste (35 IAC 807.104). • Relatively Impermeable Soil - a soil located above the water table that has a hydraulic conductivity no greater

than 1 x 10-5 centimeters per second for a thickness of at least one foot (35 IAC 830.102). • Responsible Charge - when used to refer to a person, means that the person is normally present at a waste

disposal site; directs the day-to-day overall operation at the site; and either is the owner or operator or is employed by or under contract with the owner or operator to assure that the day-to-day operations at the site are carried out in compliance with Illinois regulations (35 IAC 810.103).

• Retread or Retreading - the process of attaching tread to the casing of used tires (35 IAC 848.104) [Added May

1999]. • Runoff - water resulting from precipitation that flows overland before it enters a defined stream channel,

excluding any portion of such overland flow that infiltrates into the ground before it reaches the stream channel, and any precipitation that falls directly into a stream channel (35 IAC 830.102).

• Runon - any rainwater, leachate or other liquid that drains over land onto any part of a facility (35 IAC

830.102). • Salvaging - the return of waste materials to use, under the supervision of the landfill operator, so long as the

activity is confined to an area remote from the operating face of the landfill, it does not interfere with or otherwise delay the operations of the landfill, and it results in the removal of all materials for salvaging from the landfill site daily or separates them by type and stores them in a manner that does not create a nuisance, harbor vectors, or cause an unsightly appearance (35 IAC 807.104).

Page 188: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-10 Solid Waste Management

• Scavenging - the removal of materials from a solid waste management unit in a manner not in conformity with the regulations governing salvaging (35 IAC 807.104).

• Settlement - subsidence caused by waste loading, changes in groundwater level, chemical changes within the

soil, and adjacent operations involving excavation (35 IAC 810.103). • Sharps - includes discarded sharps used in animal or human patient care, medical research, or clinical or

pharmaceutical laboratories; hypodermic, intravenous, or other medical needles; hypodermic or intravenous syringes; pasteur pipettes; scalpel blades; blood vials; broken or unbroken glass; and needles (35 IAC 1420.102).

• Shredding - the mechanical reduction in particle sizes of solid waste. Putrescible waste is considered shredded if

90 percent of the waste by dry weight passes a 3 in. sieve (35 IAC 810.103). • Significant Modification - a modification to an approved permit issued by the Agency in accordance with

Section 39 of the Act and 35 IAC 813 that is required when one or more of the following changes, considered significant when that change measured by one or more parameters whose values lie outside the expected operating range of values as specified in the permit, are planned, occur, or will occur (35 IAC 810.103):

1. an increase in the capacity of the waste disposal unit over the permitted capacity 2. any change in the placement of daily, intermediate or final cover 3. a decrease in performance, efficiency or longevity of the liner system 4. a change in configuration, performance, or efficiency of the leachate management system 5. a change in the final disposition of treated effluent or in the quality of the discharge from the leachate treatment or pretreatment system 6. installation of a gas management system, or a decrease in the efficiency or performance of an existing gas management system 7. a change in the performance or operation of the surface water control system 8. a decrease in the quality or quantity of data from any environmental monitoring system 9. a change in the applicable background concentrations or the maximum allowable predicted concentrations 10. a change in the design or configuration of the regraded area after development or after final closure 11. a change in the amount or type of postclosure financial assurance 12. any change in the permit boundary 13. a change in the post closure land use of the property 14. a remedial action necessary to protect underground water 15. transfer of the permit to a new operator 16. operating authorization is being sought to place into service a structure constructed pursuant to a construction quality assurance program 17. a change in any requirement set forth as a special condition in the permit.

• Single-use Container - a container intended by the manufacturer for one use only, such as biohazard bags (35

IAC 1420.102). • Site - any location, place, or tract of land used for waste management. A site may include one or more units (35

IAC 807.104). • Site (in relation to special waste) - any location, place or tract of land and facilities, including but not limited to,

buildings and improvements used for purposes subject to regulation or control under special waste regulations (35 IAC 809.103) [Revised June 2000]

• Site (in relation to PIMW) - any location, place, tract of land, and facility, including but not limited to buildings,

and improvements (35 IAC 1420.102).

Page 189: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-11 Solid Waste Management

• Solid Waste - waste, including inert waste, putrescible waste, chemical waste and special waste which is not a

hazardous waste (35 IAC 807.104). • Special Handling Waste - a declassified waste which, due to its form or mode of containment in transport or

storage, presents a danger to a person handling the waste such that the person needs information about the waste to safely transport or store the waste. Special Handling Waste includes any such waste which would pose a danger if handled in a manner similar to household waste. Dangers include, but are not limited to, the following: fire, explosion, and emission of toxic or carcinogenic gas or dust. Special Handling Waste also includes any special waste which, because of appearance or packaging, resembles waste which would be a special handling waste. Such waste includes, but is not limited to, any special waste contained in a sealed drum (35 IAC 808.110).

• Solid Waste Management - waste management (35 IAC 807.104). • Special (non-RCRA) Waste - any special waste that is not a hazardous waste (35 IAC 808.110). • Special Waste - any hazardous waste, and any industrial process waste or pollution control waste which has not

been declassified pursuant to Section 808.245 (35 IAC 808.110) [Revised June 2000]. • Stability - a state in which the compost decomposes slowly even under conditions favorable for microbial

activity (35 IAC 830.102). • Staging Area - an area within a facility where raw material for composting is processed, temporarily stored in

accordance with the standards set forth in 830.205(a)(1)(A), loaded or unloaded (35 IAC 830.102). • Storage - the storage of waste, either on a temporary basis or for a period of years, in such a manner as not to

constitute disposal of such waste (35 IAC 807.104). • Storage of Special Waste - the interim containment of special waste prior to disposal or treatment (35 IAC

809.103). • Storage of PIMW - the containment of waste, either on a temporary basis or for a period of years, in such a

manner as not to constitute disposal (35 IAC 1420.102). • Storage of Tires - any accumulation of used tires that does not constitute disposal. At a minimum, such an

accumulation must be an integral part of the systematic alteration, reuse, reprocessing, or conversion of the tire in the regular course of business (35 IAC 848.104).

• Surface Impoundment - a natural topographic depression, a man-made excavation, or a diked area into which

flowing wastes, such as liquid wastes or wastes containing free liquids are placed. For the purposes of 35 IAC 811 through 815, a surface impoundment is not a landfill (35 IAC 810.103).

• Surface Water - as applies to composting operations, all tributary streams and drainage basins, including natural

lakes and artificial reservoirs, which may affect a specific water supply above the point of water supply intake. Such term does not include treatment works (such as a retention basin) (35 IAC 830.102).

• Surface Water - all water the surface of which is exposed to the atmosphere (35 IAC 807.104). • Tire - a hollow ring, made of rubber or similar materials, which was manufactured for the purpose of being

placed on the wheel rim of a vehicle (35 IAC 848.104). • Tire Carcass - the internal part of a used tire containing the piles, beads, and belts suitable for retread or

remanufacture (Section 54.10(a) of the ACT) (35 IAC 848.104) [Added May 1999].

Page 190: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-12 Solid Waste Management

• Tire Derived Fuel - a product made from used tires to exact specification of a system designed to accept a tire

derived fuel as a primary or supplemental fuel source (Section 54.10(b) of the Act) (35 IAC 848.104) [Added May 1999].

• Tire Disposal Site - a site where used tires have been disposed of other than at a landfill permitted by the

Agency (35 IAC 848.104). • Tire Storage Site - a site where used tires are stored or processed, other than the site at which the tires were

separated from the vehicle wheel rim, the site where the used tires were accepted in trade as part of a sale of new tires, or a site at which both new and used tires are sold at retail in the regular course of business, and at which not more than 250 used tires are kept at any time or a facility at which tires are sold at retail provided that the facility maintains less than 1300 recyclable tires, 1300 tire carcasses, and 1300 used tires on a site and those tires are stored inside a building so that they are prevented from accumulating water (35 IAC 848.104) [Revised May 1999].

• Tire Storage Unit - a pile of tires or a group of piles of tires at a tire storage site (35 IAC 848.104). • Tire Transporter - a person who transports used or waste tires in a vehicle (35 IAC 848.104). • Treatment - any method, technique or process designed to change the physical, chemical or biological character

or composition of any waste so as to neutralize such waste or so as to render such waste safer for transport, amendable for storage, or reduced in volume (35 IAC 807.104).

• Treatment (in relation to PIMW) - any method, technique or process, including neutralization, designed to

change the physical, chemical, or biological character or composition of any waste so as to neutralize it or render it nonhazardous, safer for transport, amenable for recovery, amenable for storage, or reduced in volume. Such term includes any activity or processing designed to change the physical form or chemical composition of hazardous waste so has to render it nonhazardous (35 IAC 1420.102).

• 25-Yr, 24-H Precipitation Event - a precipitation event of 24-h duration with a probable recurrence interval of

once in 25 yr (35 IAC 810.103). • Unacceptable Load - a load containing waste a facility is not authorized to accept (35 IAC 830.102). • Underground Water - all water beneath the land surface (35 IAC 830.102). • Unit - any device, mechanism, equipment or area used for storage, treatment, or disposal of waste (35 IAC

807.104). • Unrecognizable - relating to a sharp that has undergone physical alteration (e.g. melting, charring, corroding, or

grinding), so that the sharp may not longer be used for its intended purpose (35 IAC 810.103). • Used Tire - a worn, damaged, or defective tire which is not mounted on a vehicle wheel rim (35 IAC 848.104). • Vector - any living agent, other than human, capable of transmitting, directly or indirectly, an infectious disease

(35 IAC 807.104). • Waste - any garbage, sludge from a waste treatment plant, water supply treatment plant, or air pollution control

facility, or other discarded material, including solid, liquid, semi-solid, or contained gaseous material resulting from industrial, commercial, mining, and agricultural operations, or from community activities, but does not include solid or dissolved materials in domestic sewage, or solid or dissolved materials in irrigation return flows or industrial discharges which are point sources subject to permits under 35 IAC 309.102 or source, special nuclear, or by-product materials as defined by the Atomic Energy Act of 1954, as amended (42 U.S.C. 2011 et

Page 191: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-13 Solid Waste Management

seq.), or any solid or dissolved material from any facility subject to the Federal Surface Mining Control and Reclamation Act of 1977 (P.L. 95-87), or the rules and regulations thereunder (Ill. Rev. Stat. 1983 Ch. 96 1/2, Par. 7901.01 et seq. And 62 Ill. Adm. Code 1700 Through 1845) Section 3(11) of the Act) (35 IAC 807.104).

• Waste Management - the process of storage, treatment, or disposal of waste, not including hauling or transport

(35 IAC 807.104). • Waste Pile - an area on which noncontainerized masses of solid, nonflowing wastes are placed for disposal. For

the purposes of 35 IAC 811 through 815, a waste pile is a landfill, unless the operator can demonstrate that the wastes are not accumulated over time for disposal. At a minimum, such demonstration shall include photographs, records, or other observable or discernible information, maintained on a yearly basis, that show that within the preceding year the waste has been removed for utilization or disposed elsewhere (35 IAC 810.103).

• Waste Stabilization - any chemical, physical, or thermal treatment of waste, either alone or in combination with

biological processes, which results in a reduction of microorganisms, including viruses, and the potential for putrefaction (35 IAC 810.103).

• Waste Tire - a used tire that has been disposed of (35 IAC 848.104). • Windrow - an elongated pile of solid waste or composting material constructed to promote composting (35 IAC

830.102). • Woody Landscape Waste - plant material greater than two inches in diameter (35 IAC 830.102). • Working Face - any part of a sanitary landfill where waste is being disposed (35 IAC 807.104).

Page 192: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-14 Solid Waste Management

Page 193: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-15 Solid Waste Management

SOLID WASTE MANAGEMENT GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: Missing Checklist Items SO.2.1.IL. General SO.5.1.IL. Permits/Notifications/Exemptions SO.6.1.IL. and SO.6.2.IL. Specific Wastes SO.9.1.IL. through SO.9.9.IL. Transportation SO.20.1.IL. through SO.20.3.IL. Municipal Solid Waste Landfills

Emissions SO.67.1.IL. through SO.67.5.IL. Medical Waste

Generators SO.105.1.IL. through SO.105.5.4.IL. Containers/Labeling/Storage Areas SO.110.1.IL. and SO.110.2.IL. Transportation SO.115.1.IL. through SO.115.3.IL. Treatment/Disposal SO.120.1.IL. through SO.120.7.IL.

Landfills Management of Special Wastes at Landfills SO.135.1.IL. through SO.135.5.IL. Sanitary Landfills SO.135.6.IL. through SO.135.13.IL. All New Landfills SO.135.14.IL. through SO.135.23.IL. New Putrescible and Chemical Waste Landfills SO.135.24.IL. through SO.135.47.IL.

Construction/Demolition Landfills SO.140.1.IL. through SO.140.3.IL. Waste Tire Facilities SO.160.1.IL. through SO.160.8.IL. Yard Waste/Composting SO.165.1.IL. through SO.165.5.IL.

Quality of End-Product Compost SO.165.6.IL. and SO.165.7.IL. Closure of Solid Waste Facilities SO.180.1.IL. through SO.180.8.IL.

GUIDANCE FOR APPENDIX USERS REFER TO APPENDIX NUMBERS: REFER TO APPENDIX TITLES:

9-1 Separation Distances For Tire Storage Units 9-2 Inorganic Concentration Limits for General Use Compost

Page 194: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-16 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.2. MISSING CHECKLIST ITEMS

SO.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 195: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-17 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

SO.5. GENERAL

SO.5.1.IL. Open dumping of waste is prohibited (415 Illinois Compiled Statutes (ILCS) 5/21(a) and (b), and 415 ILCS 5/55(a)(1)) [Moved in structural reorganization of SO.5 October 1999].

Verify that the facility does not cause or allow the open dumping of waste.

Verify that the facility does not allow the open dumping of any used or waste tire.

Verify that the facility does not abandon, dump, or deposit any waste upon the public highways or other public property, except in a sanitary landfill permitted by the Agency.

Page 196: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-18 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

SO.6 PERMITS/ NOTIFICATIONS/ EXEMPTIONS

SO.6.1.IL. Facilities must obtain development permits prior to the development of new solid waste management sites or the modification of existing solid waste man-agement sites (35 IAC 807.201) [Moved in structural reorganization of SO.5 October 1999].

Verify that the facility obtains a development permit from the Agency prior to:

- developing any new solid waste management site - modifying any existing solid waste management site.

SO.6.2.IL. Facilities must obtain operating permits for the use or operation of solid waste management sites (35 IAC 807.202(a) and (b)) [Moved in structural reorganization of SO.5 October 1999].

Verify that the facility obtains an operating permit from the Agency prior to using or operating a new solid waste management site.

Page 197: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-19 Solid Waste Management

Page 198: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-20 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

SO.9 SPECIFIC WASTES

SO.9.1.IL. Generators of waste must determine whether the waste is a special waste (35 IAC 808.121(a), 808.) [Moved in structural reorganization of SO.5 October 1999; Revised June 2000].

(NOTE: “Special wastes” include any hazardous waste, any industrial process waste, and any pollution control waste which has not been declassified (see SO.9.4.IL.). Special wastes are also subject to the requirements that apply to the waste as a hazardous waste, industrial process waste, or pollution control waste, as applicable.)

Verify that generators determine whether the waste is a special waste.

(BOARD NOTE: 35 Ill. Adm. Code 722 requires the generator to also determine whether the waste is a hazardous waste.)

SO.9.2.IL. Generators of special waste must meet specific management requirements (35 IAC 808.121(b) and (e) and 808.123) [Moved in structural reorganization of SO.5 October 1999; Revised June 2000].

(NOTE: Any person who generates a total quantity of special waste of 100 kg (220 lb) or less in a calendar month is not required to initiate a manifest when delivering special waste to a transporter, provided that the special waste is not accumulated for more than 180 days prior to shipment.)

Verify that generators record and maintain the quantities and dates of waste generation and accumulation to establish compliance with the small quantity exemption from manifest requirements.

Verify that waste is not delivered to a transporter or a permitted facility unless the waste conforms with the description and characteristics in the wastestream classification determination.

Verify that special waste is not delivered to a transporter unless the waste is accompanied by a manifest and the transporter has a special waste hauling permit.

(NOTE: The following are exceptions to this prohibition: - the transporter and waste are subject to a transporter exemption - the Agency has determined that the waste is not a special waste - the waste consists of municipal water or wastewater treatment plant sludge

regulated under a sludge management plan approved by the Agency.)

SO.9.3.IL. Special waste must be treated, stored, and disposed of at specific facilities (35 IAC 808.121(c)) [Moved in structural reorganization of SO.5 October 1999].

Verify that special waste is not treated, stored, or disposed of in Illinois except:

- at a facility permitted or otherwise authorized to manage the special waste - onsite at a facility owned and operated by the generator of the special waste

and subject to the onsite disposal exemption. Verify that no person delivers special waste to a transporter or a permitted facility

Page 199: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-21 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

October 1999]. without a supplemental wastestream permit.

SO.9.4.IL. Classified special wastes must be managed according to conditions specified in the Agencies classification (35 IAC 808.101(b) and 808.521) [Added June 2000].

(NOTE: Generators of special wastes may petition the Agency for a special waste classification (including declassification). Special wastes that have been classified must be managed according to the conditions issued as part of the classification. Special wastes that have been declassified are no longer subject to the requirements for special wastes.)

Verify that all special wastes that have received an Agency classification are managed according to the conditions issued under the classification.

(NOTE: The Agency will include the following conditions in each wastestream classification determination:

- wastestream description - wastestream identification number assigned to the specific determination - classification of the special waste - limitations on the management of the waste, consistent with this Part, and 35

Ill. Adm. Code 809 - a quality assurance plan - the expiration date, if any, and - such additional conditions as the Agency determines are necessary to assure

that waste managed pursuant to the classification determination is of the class specified.)

SO.9.5.IL. Special waste transported for disposal, storage, or treatment must meet management requirements (35 IAC 809.302) [Added June 2000].

Verify that no person accepts any special waste for disposal, storage or treatment within Illinois from a special waste transporter unless the special waste transporter has a valid nonhazardous special waste hauling permit or Uniform Program Registration and Permit and presents to the receiver of the special waste a completed, signed manifest which designates the receiver's facility as the destination for the special waste.

Verify that no person delivers special waste in Illinois for disposal, storage or treatment unless the person who accepts the special waste has a current, valid operating permit issued by the Agency and the necessary supplemental permits.

SO.9.6.IL. Special waste manifests must be retained by generators, transporters, and accepting facilities (35 IAC 809.501 (g)) [Added June 2000].

Verify that every generator who delivers special waste to a special waste transporter, every person who accepts special waste from a special waste transporter and every special waste transporter retains their respective parts of the special waste manifest as a record of all special waste transactions.

Verify that the parts of the special waste manifest are retained for 3 yrs and are available at reasonable times for inspection and photocopying by the Agency.

Page 200: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-22 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

SO.9.7.IL. Special waste generators who deliver nonhazardous special waste via a transporter to a facility outside the state must file an annual report (35 IAC 809.501 (h)) [Added June 2000].

Verify that every generator who delivers nonhazardous special waste via a transporter to a facility located outside Illinois files an annual report on forms prescribed by the Agency, summarizing all such activity during the preceding calendar year.

SO.9.8.IL. Facilities that accept nonhazardous special waste from a transporter must file an annual report (35 IAC 809.501 (j)) [Added June 2000].

Verify that every in-State facility that accepts nonhazardous special waste from a nonhazardous special waste transporter files a report, on forms prescribed by the Agency, summarizing all such activity during the preceding calendar year.

(NOTE: This report must be submitted to the Agency no later than 1 February.)

SO.9.9.IL. Packages used to contain special waste must meet labeling and marking requirements (35 IAC 809.402) [Added June 2000].

Verify that all packages used to contain special waste are labeled, marked, and placarded in accordance with regulations adopted by the Illinois Department of Transportation or the United States Department of Transportation or the United States Environmental Protection Agency, whichever has jurisdiction.

(NOTE: This also applies to vehicles used to transport special waste; it is repeated in SO.20.2.IL.)

Page 201: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-23 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.20. TRANSPORTATION

SO.20.1.IL. Nonhazardous special waste haulers must be permitted (35 IAC 809.201, 809.210 and 809.211) [Added June 2000].

(NOTE: Special wastes are any hazardous waste, and any industrial process waste or pollution control waste which has not been declassified.)

Verify that any person who hauls or otherwise transports any nonhazardous special waste generated within Illinois or any nonhazardous special waste to be disposed of, stored or treated within Illinois has a current, valid nonhazardous special waste hauling permit issued by the Agency (unless the transporter participates in the Uniform Program or is exempt from the nonhazardous special waste hauling permit requirements).

(NOTE: Any person who generates a total quantity of nonhazardous special waste 100 kg (220 lb) or less in any calendar month for disposal, storage or treatment within Illinois is exempt from the permit and manifest requirements.)

(NOTE: The following persons need not obtain a nonhazardous special waste hauling permit nor carry a manifest if they haul only the waste indicated:

- any person licensed in accordance with the Private Sewage Disposal Licensing Act [225 ILCS 225] and who hauls only septic tank pumpings

- any person who hauls only livestock waste intended for land application - transporters of municipal water or wastewater treatment plant sludge that is to

be applied to land and that is to be regulated under a sludge management scheme approved by the Agency

- any person licensed in accordance with Illinois Dead Animal Disposal Act [225 ILCS 610] and who hauls only grease, meat packing scraps, dead animals and parts of animals for delivery to a renderer

- any person operating under rules and regulations adopted pursuant to "An Act in relation to Oil, Gas, Coal and Other Surface and Underground Resources" [225 ILCS 725] and who hauls only oil and gas extraction wastes as defined in that Act

- any person who hauls only radioactive wastes as defined by the Radiation Protection Act [420 ILCS 40]

- any person who hauls only coal combustion fly ash - any person who hauls only declassified waste or refuse - any person who hauls only special waste exempted by 35 Ill. Adm. Code

808.123 (small quantity generators of 220 pounds or less per month of special waste)

- any person who hauls potentially infectious medical waste that is regulated under 35 Ill. Adm. Code Subtitle M

- any person who hauls used tires regulated under 35 Ill. Adm. Code 848.

SO.20.2.IL. Nonhazardous special waste must be

Verify that no person delivers any special waste unless the waste is accompanied by a manifest and the transporter has a nonhazardous special waste hauling permit

Page 202: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-24 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

accompanied by a manifest (35 IAC 809.301 and 809.501 (g)) [Added June 2000].

or Uniform Program Registration and Permit.

Verify that the transporter retains his parts of the special waste manifest for 3 yrs and makes them available at reasonable times for inspection and photocopying by the Agency.

SO.20.3.IL. Vehicles used to transport special waste must meet marking and placarding requirements (35 IAC 809.402) [Added June 2000].

Verify that all vehicles used to transport special waste and packages used to contain special waste are labeled, marked and placarded in accordance with regulations adopted by the Illinois Department of Transportation or the United States Department of Transportation or the United States Environmental Protection Agency, whichever has jurisdiction.

(NOTE: This is repeated in SO.9.5.IL.)

Page 203: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-25 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

MUNICIPAL SOLID WASTE LANDFILLS SO.67. EMISSIONS

(NOTE: An owner or operator of municipal solid waste (MSW) landfill for which construction or modification commenced before 30 May 1991, is subject to these requirements if the landfill has accepted waste at any time since 8 November 1987, or has additional design capacity available for future waste deposition. Any MSW landfill that commenced construction, reconstruction or modification on or after 30 May 1991, is subject to the requirements of 40 CFR 60, Subpart WWW, in lieu of the requirements of this Part (see section SO.67 in the U.S. TEAM Guide for details) (35 IAC 220.200).)

SO.67.1.IL. MSW landfills must submit design capacity reports (35 IAC 220.210(a) and (b)) [Added May 1999].

Verify that each MSW landfill has submitted an initial design capacity report to the Agency.

Verify that, if the landfill is subsequently modified, an amended design capacity report is submitted to the Agency.

(NOTE: Modification of a MSW landfill will subject it to the requirements of 40 CFR 60, Subpart WWW.)

SO.67.2.IL. MSW landfills with a design capacity equal to or greater than 2.5 million Mg and 2.5 million m3 must submit emissions reports (35 IAC 220.210(c) and 220.280(b)) [Added May 1999].

Verify that a MSW landfill having a design capacity equal to or greater than 2.5 million Mg and 2.5 million m3 has submitted an initial emissions report to the Agency, and submits an annual NMOC emission report by 1 June of each year.

Verify that MSW landfills with an NMOC emissions rate less than 50 Mg/yr recalculate the NMOC emission rate annually until the calculated NMOC emission rate is equal to or greater than 50 Mg/yr, or the landfill is inactive.

(NOTE: When the rate is equal to or exceeds 50 Mg/yr, the requirements for gas collection systems apply; see the following checklist item.)

SO.67.3.IL. MSW landfills with an NMOC emission rate in excess of 50 Mg/yr must meet gas collection and control requirements (35 IAC 220.210(d) and 220.280(c)) [Added May 1999].

Verify that MSW landfills with emissions equal to or greater than 50 Mg/yr install and operate either a gas collection and control system that meets the requirements of this section (SO.67.IL.), or an alternate gas collection and control system using alternate procedures for gas collection and control, determining compliance, monitoring, operation, testing, recordkeeping, or reporting, as approved by the Agency or Board, as meeting the requirements in Section 220.220(d) or (e), or Section 220.230(d) or (e) of this Subpart.

(NOTE: Such alternate system will be effective only when included in a federally enforceable permit or approved as a SIP revision.)

Verify that each MSW landfill required to install and operate a gas control and

Page 204: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-26 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

collection system submits an application for a construction permit to the Agency within 1 yr after the first report in which the emission rate exceeds 50 Mg/yr.

(NOTE: MSW landfills that elect to recalculate NMOC emissions where the recalculated value is less than 50 Mg/yr, may not be required to install and operate gas collection and control systems.)

Verify that the gas collection and control system is installed and operating within 30 months after the date when the first annual NMOC emission rate report equals or exceeds 50 Mg/yr.

Verify that, within 6 months of initial startup or upon change in method of compliance, or by 31 October 2001, whichever is later, a MSW landfill subject to the gas control requirements certifies compliance with these requirements by submitting to the Agency:

- a description of the gas collection and control system used - the date the system was installed - a demonstration that the control system meets these requirements.

SO.67.4.IL. MSW landfills with gas collection and control systems must meet reporting requirements (35 IAC 220.280(d) through (f)) [Added May 1999].

Verify that each MSW landfill with a gas collection and control system submits the following information to the Agency 30 days prior to removal or cessation of operation of the control equipment:

- certification that the operation of the collection and control system is no longer required pursuant to 35 Ill. Adm. Code, Subtitle G;

- documentation demonstrating that the 15-yr minimum control period has expired

- dated copies of the 3 successive NMOC emission rate reports demonstrating that the landfill is no longer producing 50 Mg/yr or greater of NMOC.

Verify that MSW landfills with gas collection and control systems submit to the

Agency annual reports with the following recorded information:

- value and length of time for exceedance of applicable monitored parameters - description and duration of all periods when the gas stream is diverted from

the control device through a bypass line or the indication of bypass flow - description and duration of all periods when the control device was not

operating for a period exceeding 1 hr and length of time the control device was not operating

- all periods when the collection system was not operating in excess of 5 days - the location of each exceedance of the 500 ppm methane concentration and

the concentration recorded at each location for which an exceedance was recorded in the previous month

- the date of installation and the location of each well or collection system expansion.

Page 205: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-27 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that the initial annual report is submitted within 180 days after installation and start-up of the collection and control system.

Verify that the following information is included with the initial performance test report and any subsequent performance tests:

- a diagram of the collection system showing collection system positioning including all wells, horizontal collectors, surface collectors, or other gas extraction devices, including the locations of any areas excluded from collection and the proposed sites for the future collection system expansion

- the data upon which the sufficient density of wells, horizontal collectors, surface collectors, or other gas extraction devices and the gas mover equipment sizing are based

- the documentation of the presence of asbestos or nondegradable material for each area from which collection wells have been excluded based on the presence of asbestos or nondegradable material

- the sum of gas generation flow rates for all areas from which collection wells have been excluded based on nonproductivity and the calculations of gas generation flow rate for each excluded area

- provisions for increasing gas mover equipment capacity with increased gas generation flow rate, if the present gas mover equipment is inadequate to move the maximum flow rate expected over the life of the landfill

- the provisions for the control of off-site migration of gas.

SO.67.5.IL. MSW landfills with gas collection and control systems must meet recordkeeping requirements (35 IAC 220.290) [Added May 1999].

Verify that the MSW landfill keeps the records specified in this checklist item up-to-date, readily accessible, and on-site.

Verify that these records are kept for at least 5 yr, unless another time period is specified below.

Verify that the MSW landfill keeps, for the life of the landfill, the design capacity report in which the landfill became equal to or greater than 2.5 million Mg and 2.5 million m3, the current amount of solid waste in-place, and the year-by-year waste acceptance rate.

(NOTE: Off-site records may be maintained if they are retrievable within 4 hr. Either paper copy or electronic formats are acceptable.)

Verify that the MSW landfill keeps, for the life of the control equipment, the data measured during the initial performance test or compliance determination.

Verify that records of the control device vendor specifications are maintained until removal.

Verify that the MSW landfill keeps continuous records of the equipment operating parameters as well as up-to-date, readily accessible records for periods of operation during which the parameter boundaries established during the most

Page 206: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-28 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

recent performance test are exceeded.

Verify that the MSW landfill keeps, for the life of the collection system, a plot map showing each existing and planned collector in the system and providing a unique identification location label for each collector.

Verify that the MSW landfill keeps, for all collection and control system exceedances, records of the reading the subsequent month whether or not the second reading is an exceedance, and the location of each exceedance.

Verify that owners or operators who convert design capacity from volume to mass or mass to volume to demonstrate that landfill design capacity is less than 2.5 million Mg or 2.5 million m3, as provided in the definition of "design capacity", keep records of the annual recalculation of site-specific density, design capacity, and the supporting documentation.

Page 207: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-29 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

MEDICAL WASTE SO.105. GENERATORS

SO.105.1.IL. Generators must not offer PIMW to non-permitted treatment, storage, or transfer facilities or transporters (35 IAC 1420.104(c)).

Verify that the facility does not cause or allow the delivery of any PIMW to a person or facility for storage, treatment, transfer, or transport that does not have a permit issued by the Agency to receive PIMW.

SO.105.2.IL. Generators may be required to have a permit for the treatment, storage, transfer or transportation of PIMW (35 IAC 1420.104(g) and 1420.105(c)).

Verify that the facility does not conduct any PIMW treatment, storage, or transfer operation without a permit issued by the Agency that specifically authorizes the treatment, storage, or transfer of PIMW.

(NOTE: Any person who conducts a PIMW treatment, storage, or transfer operation is required to obtain a permit from the Agency, except:

- any person conducting a PIMW treatment, storage, or transfer operation for PIMW generated by the person's own activities that are treated, stored, or transferred within the site where the PIMW is generated, or

- any hospital that treats, stores, or transfers only PIMW generated by its own activities or by members of its medical staff.)

(NOTE: Transportation of PIMW interrupted by vehicle repairs or inclement

weather does not constitute storage.)

SO.105.3.IL. Generators must segregate PIMW at the point of generation (35 IAC 1421.111).

Verify that PIMW is segregated as follows:

- sharps - oversized PIMW - all other.

(NOTE: PIMW mixed with other waste is regulated under this Subtitle as PIMW and the mixture is not exempt from any other applicable regulations.)

(NOTE: This regulation does not prohibit the placing of previously segregated and properly packaged sharps with other waste, provided the mixture is managed as PIMW.)

Page 208: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-30 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.105.4.IL. Hospitals that send medical waste to off-site hospital/medical/infectious waste incinerators (HMIWIs) must prepare and implement a waste management plan (35 IAC 229.110(e) and 229.178) [Added June 2000].

Verify that, by 15 September 2000, the owner or operator of any hospital that transfers hospital or medical/infectious waste off-site to an HMIWI conducts an assessment of its current waste management program and considers additional technically and economically feasible measures for reducing the volume and toxicity of waste to be incinerated.

Verify that, in identifying additional technically and economically feasible waste management practices, the owner or operator considers:

- segregating waste streams - phasing out the use of products containing toxic materials - reusing products and equipment - reducing the use of packaging and disposable items - collecting recyclable materials - improving inventory control, training and housekeeping practices.

Verify that, within 1 yr after the assessment, and annually thereafter, hospitals submit a waste management progress report to the Agency that summarizes any waste management policies and practices that were implemented in the previous calendar year.

Page 209: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-31 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

MEDICAL WASTE SO.110. CONTAINERS/ LABELING/ STORAGE AREAS

SO.110.1.IL. PIMW must be placed in specific containers (35 IAC 1421.121).

Verify that all PIMW is placed in containers which are:

- rigid - leak-resistant - impervious to moisture - of a strength sufficient to prevent tearing or bursting under normal conditions

of use and handling - sealed to prevent leaking during transport.

Verify that all sharps, unless treated and rendered unrecognizable, are packaged in

a container, or a combination of containers, that are:

- puncture-resistant. - rigid - leak-resistant - impervious to moisture - of a strength sufficient to prevent tearing or bursting under normal conditions

of use and handling - sealed to prevent leaking during transportation.

Verify that oversized PIMW is covered or packaged in a manner that minimizes contact with transport workers and the public.

Verify that sharps are not packaged with oversized PIMW in the same container.

Verify that if the outside of a container is contaminated by PIMW, a person places the container inside another container, or cleans and disinfects the container.

(NOTE: Once a reusable container has been cleaned and disinfected, it can be used for only waste. If a reusable container is not or cannot be cleaned and disinfected, it must be regulated as PIMW pursuant to this Subtitle.)

Verify that residues from cleaning a PIMW container, or discharges from PIMW packages, are handled as PIMW, except when discharged directly into a sanitary or combined sewer in accordance with wastewater disposal regulations.

(BOARD NOTE: Interested persons should note that discharges to sewer systems can also be regulated by units of local government.)

Page 210: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-32 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.110.2.IL. Facilities that store PIMW prior to treatment, disposal, or transport off-site must meet specific storage requirements (35 IAC 1421.111(a)).

Verify that PIMW is stored in a manner and location that:

- maintains the integrity of the packaging and provides protection from water, rain, and wind

- maintains the PIMW in a nonputrescent state, using refrigeration when necessary.

Verify that outdoor storage areas containing PIMW are locked to prevent unauthorized access, and limits access to on-site storage areas to authorized employees.

Verify that PIMW is stored in a manner that affords protection from animals and does not provide a breeding place or food source for vectors.

Verify that PIMW packages are not compacted or subjected to stress that compromises the integrity of the container.

Verify that reusable PIMW containers or facility equipment (e.g., carts, squeegees or shovels) which are visually contaminated with PIMW are cleaned in a designated area.

Verify that residues from cleaning a PIMW contaminated container, equipment or work surface are managed as PIMW, except when directly discharged into a sanitary or combined sewer in accordance with wastewater disposal regulations.

(BOARD NOTE: Interested persons should note that discharges to sewer systems can also be regulated by units of local government.)

Verify that copies of all PIMW manifests are retained by and kept at the storage operation for three years and made available at the storage operation during normal business hours for inspection and photocopying by the Agency.

Verify that upon closure of a storage operation, the owner or operator cleans the area, equipment and structures.

(NOTE: There are additional requirements for permitted facilities; refer to the permit for details.)

Page 211: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-33 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

MEDICAL WASTE SO.115. TRANSPORTATION

SO.115.1.IL. Transporters of PIMW must be permitted (35 IAC 1420.104(c) and 1420.105(e)).

Verify that the facility does not cause or allow the delivery or transfer of any PIMW for transport unless the transporter has a permit issued by the Agency to transport PIMW and a PIMW manifest is completed for the waste.

(NOTE: PIMW being transported by generators who generated the waste by their own activities when the PIMW is transported within or between sites for facilities owned, controlled, or operated by that generator are not required to have a manifest.)

SO.115.2.IL. PIMW packaging transported offsite must meet specific labeling requirements (35 IAC 1421.131).

Verify that all PIMW packages transported offsite have the following markings (made by the generator):

- markings on two opposite sides of the outer package in lettering that is readable at a minimum distance of 5 ft:

- the International Biohazard Symbol and the word BIOHAZARD - the word SHARPS, if the package contains sharps

- markings in indelible ink in lettering that is legible on a water-resistant label or tag securely attached to or marked on the outer package:

- the generator’s name - the generator’s address - the generator’s phone number (a 24-h phone number, if available).

Verify that all PIMW packages transported offsite have the following markings

(made by the transporter) in indelible ink in lettering that is legible on a water-resistant label or tag securely attached to or marked on the outer package:

- the transporter’s name - the transporter’s permit number - the transporter’s address - the transporter’s phone number (a 24-h phone number if available) - for each PIMW package, the shipment date when the PIMW initially left the

generator’s site; or for each shipment, a unique identification number which directly corresponds to the initial date of shipment.

Verify that inner packages are marked with the International Biohazard Symbol

and the word BIOHAZARD.

Verify that, if a sharps container is packaged within an outer container, the inner sharps container is marked with indelible ink in lettering that is legible with the

Page 212: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-34 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

International Biohazard Symbol and the words BIOHAZARD and SHARPS.

Verify that a nonrigid container is not used as an outer container.

Verify that, when oversized PIMW is transported by more than one transporter, each transporter marks with indelible ink in lettering that is legible on a water-resistant label or tag securely attached to or marked on the outer package:

- the transporter’s name - the transporter’s permit number - the transporter’s address - the transporter’s phone number (a 24-h phone number if available) - for each PIMW package, the shipment date when the PIMW initially left the

generator’s site; or for each shipment, a unique identification number which directly corresponds to the initial date of shipment.

(NOTE: The label, tag, or mark must not obscure any previous information on the

package.)

SO.115.3.IL. Transportation of PIMW must meet certain standards (35 IAC 1421.141).

Verify that the PIMW is transported under conditions that minimize the effects of putrescence.

Verify that packages of PIMW are transported only in enclosed compartments of vehicles that are secured against public access when unattended.

Verify that oversized PIMW is handled in a manner that minimizes contact with transport workers and the public.

Verify that vehicles and associated storage compartments, doors, piping, and valving are cleaned of visible PIMW contamination after each use and are in good repair when transporting PIMW.

Verify that PIMW is transported in a manner that prevents a breeding place or food source for vectors.

Verify that during transport, PIMW packages are not compacted or subjected to stress that compromises the integrity of the container.

Verify that residues from the cleaning of vehicles contaminated by PIMW are treated as PIMW, unless discharged directly into a sanitary or combined sewer, vehicles transporting PIMW display information in accordance with the PIMW hauling permit.

Verify that transporters of PIMW develop and keep an emergency response plan in the vehicle identifying the names and telephone numbers of state and local authorities who must be contacted in the event of an emergency or discharge.

Page 213: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-35 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that each vehicle which transports PIMW carries all equipment necessary to provide a response to an emergency or discharge.

Verify that vehicles transporting PIMW are not used for hauling of nonwaste materials, with the exceptions of equipment and supplies intended for the use of waste management, including scales, bar coding equipment, printers, stampers, manifests, logs, dollies, load locks, conveyers, material handling equipment, plastic containers, corrugated boxes, plastic bags, tape, sharps containers, drums, labels, signs, stickers, spill kits, new PIMW containers or PIMW containers that have been cleaned and disinfected.

Verify that PIMW is not transported for more than 10 calendar days.

Page 214: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-36 Solid Waste Management

Page 215: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-37 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

MEDICAL WASTE SO.120. TREATMENT/DISPOSAL

SO.120.1.IL. The discharge of PIMW is prohibited (35 IAC 1420.104(k) and (l)).

Verify that PIMW is not discharged from a vehicle.

Verify that the discharge of PIMW into a sanitary or combined sewer is not allowed except in accordance with the state’s water pollution requirements.

Verify that inert or solid PIMW, or inert or solid materials resulting from the treatment of PIMW is not discharged into any sanitary sewerage system, combined sewerage system, or storm sewerage system directly or indirectly tributary to waters of the State.

(NOTE: This prohibition applies to, but is not limited to, absorbents, aluminum or other metallic foils, ash, bone, bedding materials, cellulose, culture dishes, garments and other cloth materials, gauze, glass, pads, plastic, sharps, shavings, straw, and syringes.)

SO.120.2.IL. The disposal of sharps in a landfill must meet certain standards (35 IAC 1420.104(a)).

Verify that sharps are disposed of in a landfills only if:

- the landfill is permitted by the Agency to accept sharps - the infectious potential has been eliminated from the sharps by treatment - the sharps are packaged in a container which has the following

characteristics: - puncture-resistant

- rigid - leak-resistant - impervious to moisture - of a strength sufficient to prevent tearing or bursting under normal

conditions of use and handling - sealed to prevent leaking during transportation.

SO.120.3.IL. PIMW treatment facilities must meet specific operating standards (35 IAC 1420.120, 1420.121, and 1420.122(a)(1) through (7)).

Verify that the treatment of PIMW is conducted in a manner that:

- eliminates the infectious potential of the waste - prevents the compaction and rupture of containers during handling

operations, except when compaction or rupture is an integral part of the treatment process and the treatment process is conducted without discharge of PIMW to the environment

- disposes of treatment residuals in accordance with this Act and regulations

Page 216: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-38 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- provides for quality assurance programs that must include, at a minimum, a written plan

- provides for periodic testing using biological testing, where appropriate, that demonstrate proper treatment of the waste

- provides for assurances that clearly demonstrate that potentially infectious medical waste has been properly treated; and

- is in compliance with all federal and state laws and regulations pertaining to environmental protection.

SO.120.4.IL. Ash and residue from PIMW treatment must be managed as PIMW (35 IAC 1420.122(b)(1) and (2)).

Verify that residues from cleaning a PIMW contaminated container, equipment or work surface are managed as PIMW, except when directly discharged into a sanitary or combined sewer in accordance wastewater disposal regulations.

(BOARD NOTE: Interested persons should note that discharges to sewer systems can also be regulated by units of local government.)

(NOTE: Ash resulting from the incineration of PIMW is an industrial process waste, and must be managed as a special waste (see section SO.5. above).)

SO.120.5.IL. PIMW treatment facilities must meet recordkeeping and reporting requirements (35 IAC 1420.122(a)(3) and (4)).

Verify that copies of PIMW manifests are kept at the treatment facility for 3 yr and are made available at the treatment facility during normal business hours for inspection and photocopying by the Agency.

Verify that each treatment facility that is required to have a permit and each facility not required to have a permit that treats more than 50 lb/mo of PIMW files a report with the Agency specifying the quantities and disposition of PIMW treated during the previous calendar year.

SO.120.6.IL. PIMW treatment facilities must meet specific operating standards (35 IAC 1420. 122(a)(5)).

Verify that upon closure of a treatment facility, the owner/operator cleans the area, equipment, and structures.

Page 217: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-39 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.135. LANDFILLS

Management Of Special Wastes At Landfills

(NOTE: This subsection applies to all landfills permitted by the Agency pursuant to Section 21 of the Act, including landfills operated on-site, with or without a permit, that accept special wastes. Inspection, testing or acceptance of waste by a solid waste management facility does not relieve the generator or transporter of responsibility for compliance.)

SO.135.1.IL. Landfills must provide notice to generators and transporters of special wastes (35 IAC 811.402).

Verify that a prominent sign at the entrance to each solid waste management facility states that disposal of hazardous waste is prohibited and, if it is a facility permitted by the Agency to accept special wastes, also states that special waste will be accepted only if accompanied by an identification record and a manifest (unless such waste is exempted from the manifest requirements).

SO.135.2.IL. Landfills must not accept special wastes unaccompanied by manifest (35 IAC 811.403) [Revised June 2000].

Verify that each special waste accepted for disposal at a permitted solid waste management facility is accompanied by a manifest containing the following information, (unless such special waste is disposed at an on-site facility and exempted from the manifest requirement):

- the name of the generator of the special waste - when and where the special waste was generated - the name of the special waste transporter - the name of the solid waste management facility to which it is shipped as a

final destination point - the date of delivery - the name, waste stream permit number (if applicable) and quantity of special

waste delivered to the transporter - the signature of the person who delivered the special waste to the special

waste transporter, acknowledging such delivery - the signature of the special waste transporter, acknowledging receipt of the

special wastes - the signature of the person who accepted the special waste at its final destina-

tion, acknowledging acceptance of the special waste.

(NOTE: A permitted facility that accepts special waste must be designated on the manifest as the final destination point. Any subsequent delivery of the special waste or any portion or product thereof to a special waste transporter will be conducted under a transportation record initiated by the permitted solid waste management facility.)

Page 218: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-40 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that the receiving solid waste management facility accepts special waste only if accompanied by three copies of the manifest from the transporter (the transporter retains one copy).

Verify that the receiving solid waste management facility distributes copies of the manifest as follows:

- sends one copy of the completed transportation record to the person who delivered the special waste to the special waste transporter (usually the generator, or another special waste management facility)

- send one copy of each signed manifest to the Agency - send information on rejected loads to the Agency in a quarterly report.

Verify that every person who delivers special waste to a special waste transporter, every person who accepts special waste from a special waste transporter, and every special waste transporter retains a copy of the special waste transportation record as a record of each special waste transaction.

Verify that these copies are retained for 3 yr and made available at reasonable times for inspection and photocopying by the Agency.

SO.135.3.IL. Each special waste disposed at a landfill must be accompanied by a special waste profile identification sheet (35 IAC 811.404).

Verify that each special waste disposed of at a facility (including special wastes generated at the facility) is accompanied by a special waste profile identification sheet, from the waste generator, that certifies the following:

- the generator's name and address - the transporter's name and telephone number - the name of waste - the process generating the waste - physical characteristics of waste (e.g., color, odor, solid or liquid, flash point) - the chemical composition of the waste - the metals content of the waste - hazardous characteristics (including identification of wastes deemed

hazardous by the U.S. EPA or the state) - presence of polychlorinated biphenyls (PCB)s or 2,3,7,8-tetrachlorodibenzo-

dioxin (2,3,7,8-TCDD) - any other information, such as the result of any test that can be used to deter-

mine: - whether the special waste is regulated as a hazardous waste

- whether the special waste is of a type that is permitted for or has been classified for storage, treatment, or disposal at the facility

- whether the method of storage, treatment, or disposal, using the methods available at the facility, is appropriate for the waste.

Verify that each subsequent shipment of a special waste from the same generator is

accompanied by a transportation record, a copy of the original special waste

Page 219: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-41 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

profile identification sheet, and either:

- a special waste recertification by the generator describing whether there have been changes in the following:

- laboratory analysis (copies to be attached) - raw material in the waste-generating process - the waste-generating process itself - the physical or hazardous characteristics of the waste - new information on the human health effects of exposure to the waste;

or - certification indicating that any change in the physical or hazardous

characteristic of the waste is not sufficient to require a new special waste profile.

SO.135.4.IL. Solid waste management facility operators that receive special wastes must meet specific recordkeeping requirements (35 IAC 811.405).

Verify that the operator retains copies of any special waste profile identification sheets, special waste recertifications, certifications of representative sample, special waste laboratory analyses, special waste analysis plans, and any waivers of requirements (prohibitions, special waste management authorization, and operating requirements) at the facility until the end of the postclosure care period.

SO.135.5.IL. Solid waste management facility operators must check incoming loads for hazardous waste (35 IAC 811.406).

Verify that the operator implements a load checking program for detecting and dis-couraging attempts to dispose of regulated hazardous wastes at the facility.

Sanitary Landfills (NOTE: The requirements of Part 807, including those in this subsection, provide the minimum regulatory requirements for landfills in Illinois, and are superseded by the requirements for new landfills, where applicable.)

SO.135.6.IL. Sanitary landfills must follow specific methods of operation (35 IAC 807.303).

Verify that, unless otherwise specifically provided by permit, the following methods of operations are followed:

- unloading - all refuse is deposited into the toe of the fill or into the bottom of the trench

- spreading and compacting - as rapidly as refuse is deposited at the toe of the fill, all refuse is spread and compacted in layers within the cell, such layers not to exceed a depth of 2 ft

- working face - the slope of the working face is maintained at a ratio of no greater than two horizontal to one vertical.

Page 220: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-42 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.135.7.IL. Sanitary landfills must meet equipment and personnel requirements (35 IAC 807.304).

Verify that sufficient equipment, personnel, and supervision are available at the site to ensure that operations comply with the permit and the Act and Regulations.

SO.135.8.IL. Sanitary landfills must meet specific cover requirements (35 IAC 807.305).

Verify that, unless otherwise specifically provided by permit, the following cover requirements are followed:

- daily cover--a compacted layer of at least 6 in, of suitable material is placed on all exposed refuse at the end of each day of operation

- intermediate cover--at the end of each day of operation, in all but the final lift of a sanitary landfill, a compacted layer of at least 12 in, of suitable material is placed on all surfaces of the landfill where no additional refuse will be deposited within 60 days

- final cover-- a compacted layer of not less than 2 ft of suitable material is placed over the entire surface of each portion of the final lift not later than 60 days following the placement of refuse in the final lift, unless a different schedule has been authorized in the Operating Permit.

SO.135.9.IL. Sanitary landfill operators must control litter, salvaging, scavenging, and animal access to (35 IAC 807.306 through 807.309).

Verify that all litter is collected from the sanitary landfill site by the end of each working day and either placed in the fill and compacted and covered that day, or stored in a covered container.

Verify that all salvaging operations at a sanitary landfill site are conducted in a sanitary manner.

Verify that all salvaging operations at a sanitary landfill site are confined to an area remote from the operating face of the landfill.

Verify that salvaging operations at a sanitary landfill site do not interfere with, or otherwise delay the operation of, the landfill.

Verify that all materials for salvaging are removed from the landfill site daily, or are separated by type and properly stored so as not to create a nuisance, vector harborage, or unsightly appearance.

Verify that scavenging operations are not allowed at a sanitary landfill site.

Verify that feeding of farm or domestic animals upon the site of a sanitary landfill, or with refuse delivered to sanitary landfill site, is not allowed.

Page 221: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-43 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.135.10.IL. The disposal of hot wastes and hazardous and liquid wastes are restricted at sanitary landfills (35 IAC 807.310).

Verify that, except in an emergency, burning material is not deposit at a sanitary landfill site.

(NOTE: When such material is accepted, it must be deposited at a specific location at the site designated by permit for such purpose, and the fire immediately extinguished.)

Verify that hazardous and liquid wastes are accepted at a sanitary landfill only if authorized by permit.

SO.135.11.IL. Sanitary landfills must not be sources of air or water pollution (35 IAC 807.311, 807.312, 807.313, and 807.315).

Verify that open burning at a sanitary landfill site is not allowed except in accordance with the provisions of the air quality regulations.

Verify that the operation of a sanitary landfill does not cause or allow the discharge or emission of any contaminant into the environment in any State so as to cause or tend to cause air pollution in Illinois, either alone or in combination with contaminants from other sources, or so as to violate regulations or standards adopted by the Board under the Act.

Verify that the operation of a sanitary landfill does not cause or allow the discharge of any contaminants into the environment in any State so as to cause or tend to cause water pollution in Illinois, either alone or in combination with matter from other sources, or so as to violate regulations or standards adopted by the Pollution Control Board under the Act.

SO.135.12.IL. Sanitary landfills must meet certain standard design and opera-tional standards (35 IAC 807.314).

(NOTE: The Agency may authorize, in writing, changes to these operating stan-dards.)

Verify that adequate shelter, sanitary facilities, and emergency communications are provided for employees.

Verify that roads are adequate for orderly operations within the site.

Verify that fencing, gates, or other measures are provided to control access to site

Verify that adequate measures for fire protection, as approved by the Agency, are provided.

Verify that there are adequate measures to monitor and control leachate.

Verify that there are adequate measures to control dust and vectors.

Page 222: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-44 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that an operational safety program, approved by the Agency, is provided.

Verify that new sanitary landfill sites provide for the concealment of sanitary landfill operations from public view.

SO.135.13.IL. Owners/ operators of sanitary landfill sites must meet specific closure requirements (35 IAC 807.318).

Verify that sanitary landfill site monitoring for gas, water and settling continues at the completed site for a period of three years after the site is completed or closed.

Verify that any remedial action necessary, to abate any gas, water or settling problems which appear during the three year period, is taken.

Verify that, upon completion or closure, the owner/operator files a detailed description of the site, including a plat, with the appropriate county land recording authority for the county in which the site is located.

All New Landfills (NOTE: Existing landfills are subject to the same requirements as new landfills, with certain exemptions depending upon the type of landfill and its date of required closure. Refer to permit applications for each existing landfill for details.)

(NOTE: These requirements also apply to new MSWLFs.)

SO.135.14.IL. All new landfill facilities must meet specific location standards (35 IAC 811.102).

Verify that all new landfill facilities meet the following location standards:

- the facility meets all requirements under the Wild and Scenic Rivers Act (16 U.S.C. 1271 et seq.)

- the facility does not restrict the flow of a 100-year flood, result in washout of solid waste from the 100-year flood, or reduce the temporary water storage capacity of the 100-year floodplain, unless measures are undertaken to provide alternative storage capacity such as lagoons, holding tanks, or provision of drainage around structures at the facility

- the facility is not located in areas where it may pose a threat of harm or destruction to the features for which an irreplaceable historic, or archaeological site was listed pursuant to the National Historic Preservation Act (16 U.S.C. 470 et seq.) or the Illinois Historic Preservation Act (Ill. Rev. Stat. 1989, ch. 127, par. 133d1 et seq.) for which a Natural Landmark was designated by the National Park Service or the Illinois State Historic Preservation Officer, or for which a natural area was designated as a Dedicated Illinois Nature Preserve pursuant to the Illinois Natural Area Preservation Act (Ill. Rev. Stat. 1989, ch. 105 par. 701 et seq.)

- the facility is not located in areas where it may jeopardize the continued existence of any designated endangered species, result in the destruction or adverse modification of the critical habitat listed for such species, or cause or contribute to the taking of any endangered or threatened species of plant, fish

Page 223: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-45 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

or wildlife listed pursuant to the Endangered Species Act 16 U.S.C. 1531 et seq., or the Illinois Endangered Species Protection Act (Ill. Rev. Stat. 1989, ch. 8, par. 331 et seq.)

- the facility does not cause a violation of Section 404 of the Clean Water Act (33 U.S.C. 1344)

- the facility does not cause a violation of any requirements implementing an areawide or statewide water quality management plan for nonpoint source pollution that has been approved under Section 208 of the Clean Water Act (33 U.S.C 1288).

SO.135.15.IL. Runoff at new landfill units must be controlled (35 IAC 811.103).

Verify that runoff from disturbed areas meets the following restrictions:

- runoff from disturbed areas resulting from precipitation events less than or equal to the 25-yr, 24-hr precipitation event that is discharged to waters of the state meets the requirements of 35 Ill. Adm. Code 304

- all discharges of runoff from disturbed areas to waters of the state are permitted by the Agency

- all treatment facilities are equipped with bypass outlets designed to pass the peak flow of runoff from the 100-yr, 24-hr precipitation event without damage to the treatment facilities or surrounding structures

- all surface water control structures are operated until the final cover is placed and erosion stability is provided by vegetative or other cover

- all discharge structures are designed to have flow velocities that will not cause erosion and scouring of the natural or constructed lining (i.e., bottom and sides, of the receiving stream channel).

Verify that the diversion of runoff from undisturbed areas meets the following

restrictions:

- runoff from undisturbed areas is diverted around disturbed areas unless the operator shows that it is impractical based on site-specific conditions

- diversion facilities are designed to prevent runoff from the 25-yr, 24-hr precipitation event from entering disturbed areas

- runoff from undisturbed areas which becomes commingled with runoff from disturbed areas is handled as runoff from disturbed areas

- all diversion structures are designed to have flow velocities that will not cause erosion and scouring of the natural or constructed lining (i.e., the bottom and sides, of the diversion channel and downstream channels)

- all diversion structures are operated until the final cover is placed and erosional stability is provided by vegetative or other cover.

SO.135.16.IL. Boundaries of all new landfill facilities must meet specific standards (35 IAC 811.104).

Verify that the boundaries of all waste disposal units, property boundaries, disturbed areas, and the permit area for facilities are surveyed and marked by a professional land surveyor.

Page 224: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-46 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

IAC 811.104). Verify that all stakes and monuments are clearly marked for identification.

Verify that all stakes and monuments are inspected annually and surveyed no less frequently than once in 5 yr by a professional land surveyor, who also replaces monuments discovered during an inspection.

Verify that control monuments are established to check vertical elevations.

(NOTE: The control monuments must be established and maintained by a profes-sional land surveyor.)

SO.135.17.IL. Waste compaction at new landfills must be done according to specific standards (35 IAC 811.105).

Verify that all wastes are deposited at the lowest part of the active face, and com-pacted to the highest achievable density necessary to minimize void space and settlement unless precluded by extreme weather conditions.

(NOTE: The Agency may approve an alternative location for placement of wastes, if the operator demonstrates that it is required under the conditions existing at the site or for reasons of safety.)

SO.135.18.IL. Daily cover at all new landfills must meet minimum standards (35 IAC 811.106).

Verify that a uniform layer of at least 0.15 m (6 in.) of clean soil material is placed on all exposed waste by the end of each day of operation.

(NOTE: Alternative materials or procedures, including the removal of daily cover prior to additional waste placement, may be used, provided that the alternative materials or procedures achieve equivalent or superior performance in the following areas:

- prevention of blowing debris - minimization of access to the waste by vectors - minimization of the threat of fires at the open face - minimization of odors.)

SO.135.19.IL. All new landfill facilities must meet specific operating standards (35 IAC 811.107(a) through (l)).

Verify that waste is placed in a manner and at such a rate that mass stability is pro-vided during all phases of operation.

(NOTE: Mass stability means that the mass of waste deposited will not undergo settling or slope failure that interrupts operations at the facility or causes damage to any of the various landfill operations or structures, such as the liner, leachate or drainage collection system, gas collection system, or monitoring system.)

Verify that the phasing of operations at the facility is designed in such a way as to allow the sequential construction, filling, and closure of discrete units or parts of units.

Page 225: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-47 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that the operator designs and sequences the waste placement operation in each discrete unit or parts of units, in conjunction with the overall operations of the facility, so as to shorten the operational phase and allow wastes to be built up to the planned final grade.

Verify that the working face of the unit is no larger than is necessary, based on the terrain and equipment used in waste placement, to conduct operations in a safe and efficient manner.

Verify that the slopes of the working face area are no steeper than two to one (horizontal to vertical) unless the waste is stable at steeper slopes.

Verify that equipment is maintained and available for use at the facility during all hours of operation, so as to achieve and maintain compliance with the requirements of this Part.

Verify that all utilities, including but not limited to heat, lights, power and communications equipment, necessary for safe operation in compliance with the requirements of this Part are available at the facility at all times.

Verify that the operator maintains and operates all systems and related appurtenances and structures in a manner that facilitates proper operations in compliance with this Part.

Verify that open burning is prohibited at the landfill except in accordance with 35 Ill. Adm. Code 200 through 245.

Verify that the operator implements methods for controlling dust so as to prevent wind dispersal of particulate matter.

Verify that the facility is designed, constructed and maintained to minimize the level of equipment noise audible outside the facility, or cause or contribute to a violation of 35 Ill. Adm. Code 900 through 905 or of Section 24 of the Act.

Verify that measures are implemented to control the population of disease and nui-sance vectors.

Verify that the operator institutes fire protection measures including, but not limited to, maintaining a supply of water onsite and radio or telephone access to the nearest fire department.

Verify that the operator patrols the facility daily to check for litter accumulation, and that all litter is collected and placed in the fill or in a secure, covered container for later disposal.

Verify that the solid waste is not accepted from vehicles that do not utilize devices such as covers or tarpaulins to control litter, unless the nature of the solid waste load is such that it cannot cause any litter during its transportation to the facility.

Page 226: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-48 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that the methods, such as use of wheel washing units, are implemented to prevent tracking of mud by hauling vehicles onto public roadways.

SO.135.20.IL. Salvaging operations at new landfills must be conducted according to specific standards (35 IAC 811.108).

Verify that all salvaging operations in no way interfere with the operation of the waste disposal facility, result in a violation of any standard, or delay the construction or interfere in the operation of the liner, leachate collection system, daily, intermediate or final cover and any monitoring devices.

Verify that all salvaging operations is performed in a safe and sanitary manner.

Verify that salvageable materials that are accumulated onsite are:

- managed so as not to create a nuisance, harbor vectors, cause malodors, or create an unsightly appearance

- not accumulated for longer than seven days, unless, the Agency has issued a permit with alternative conditions for management of such materials.

SO.135.21.IL. New landfill facilities must control access to the facility (35 IAC 811.109).

Verify that access to the open face area of the unit and all other areas within the boundaries of the facility is restricted to prevent unauthorized entry at all times.

Verify that a permanent sign is posted at the entrance to the facility stating that dis-posal of hazardous waste is prohibited and, if the landfill is approved for accepting special wastes, that special wastes must be permitted by the Agency and accompanied by a manifest and an identification record, along with the following information:

- permit number, if the facility is subject to the permit requirements of Section 21 of the Act

- hours of operation - the penalty for unauthorized trespassing and dumping - the name and telephone number of the appropriate emergency response

agencies who are available to deal with emergencies and other problems, if different that the operator

- the name, address, and telephone number of the company operating the facility.

SO.135.22.IL. All new landfill facilities must meet specific closure requirements (35 IAC 811.110(a) through (d)(2)).

(NOTE: These requirements, like all other in this manual, are in addition to the Federal requirements.)

Verify that the final slopes and contours are designed to complement and blend with the surrounding topography of the proposed final land use of the area.

Verify that all drainage ways and swales are designed to safely pass the runoff

Page 227: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-49 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

from the 100-yr, 24-hr precipitation event without scouring or erosion.

Verify that the final configuration of the facility is designed in a manner that mini-mizes the need for further maintenance.

Verify that the operator maintains a written plan describing all actions that the operator will undertake to close the unit or facility.

(NOTE: A modification of the written closure plan constitutes a significant modi-fication of the permit.)

SO.135.23.IL. New landfill facilities must meet specific postclosure maintenance requirements (35 IAC 811.111(a) through (c)).

Verify that the operator treats, removes from the site, or disposes of all wastes and waste residues within 30 days after receipt of the final volume of waste.

Verify that the operator removes all equipment or structures not necessary for the postclosure land use, unless otherwise authorized by permit.

Verify that the operator conducts a quarterly inspection of all vegetated surfaces for a minimum of 5 yr after closure (after 5 yr, the operator may reduce the frequency of annual inspections until settling has stopped and there are no eroded or scoured areas).

Verify that, for landfills other than those used exclusively for disposing waste generated at the site, inspections are continued for a minimum period of 15 yr after closure.

Verify that, for MSWLF units, inspections are continued for a minimum period of 30 yr after closure.

(NOTE: The Agency may reduce the inspection and maintenance period at a MSWLF unit upon a demonstration by the owner or operator that the reduced period is sufficient to protect human health and environment.)

New Putrescible and Chemical Waste Landfills

(NOTE: In addition to the requirements for All New Landfills (above), the standards of this subsection apply to all landfills in which chemical and putrescible wastes are to be placed.)

SO.135.24.IL. Putrescible and chemical waste landfills are subject to additional location restrictions (35 IAC 811.302).

Verify that no part of a unit is located within a setback zone.

Verify that no part of a unit is located within the recharge zone or within 366 m (1200 ft), vertically or horizontally, of a sole-source aquifer, unless there is a stratum between the bottom of the waste disposal unit and the top of the aquifer that meets the following minimum requirements:

Page 228: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-50 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

that meets the following minimum requirements:

- the stratum has a minimum thickness of 15.2 m (50 ft) - the maximum hydraulic conductivity in both the horizontal and vertical direc-

tions is no greater than 1 x 10-7 cm/sec, as determined by in situ borehole or equivalent tests

- there is no indication of continuous sand or silt seams, faults, fractures or cracks within the stratum that may provide paths for migration

- age dating of extracted water samples from both the aquifer and the stratum indicates that the time of travel for water percolating downward through the relatively impermeable stratum is no faster than 15.2 m (50 f t) in 100 yr.

Verify that a facility located within 152 m (500 ft) of the right of way of a

township or county road or state or interstate highway has its operations screened from view by a barrier of natural objects, fences, barricades, or plants no less than 2.44 m (8 ft) in height.

Verify that no part of a unit is located closer than 152 m (500 ft) from an occupied dwelling, school, or hospital that was occupied on the date when the operator first applied for a permit to develop the unit or the facility containing the unit, unless the owner of such dwelling, school, or hospital provides permission to the operator, in writing, for a closer distance.

Verify that the facility is not located closer than 1525 m (5000 ft) of any runway used by piston type aircraft or within 3050 m (10,000 ft) of any runway used by turbojet aircraft unless the Federal Aviation Administration provides the operator with written permission, including technical justification, for a closer distance.

SO.135.25.IL. Putrescible and chemical waste disposal units must meet specific design period standards (35 IAC 811.303).

Verify that the design period for putrescible and chemical waste disposal units is the estimated operating life plus a postclosure care period of 30 yr.

(NOTE: The design period for putrescible waste landfill units, other than MSWLF units, may be reduced if measures are undertaken to encourage stabilization of putrescible waste.)

Verify that the design period for a disposal unit which accepts only putrescible waste in shredded form is the estimated operating life plus 20 yr of postclosure care.

Verify that the design period for a putrescible waste disposal unit that recycles leachate is the estimated operating life plus 20 yr of postclosure care.

SO.135.26.IL. Putrescible and chemical waste landfills must have liner systems that

Verify that all units are equipped with a leachate drainage and collection system and a compacted earth liner designed as an integrated system.

Page 229: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-51 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

meet specific standards (35 IAC 811.306).

Verify that the liner and leachate collection system are stable during all phases of construction and operation, and that the side slopes achieve a minimum static safety factor of 1.3 and a minimum seismic safety factor of 1.0 at all times.

Verify that the liner is designed to function for the entire design period.

Verify that, for compacted earth liners:

- the minimum allowable thickness is 1.52 m (5 ft) - the liner is compacted to achieve a maximum hydraulic conductivity of 1 x

10-7 cm/sec - the construction and compaction of the liner are carried out in accordance

with construction quality assurance procedures so as to reduce void spaces and allow the liner to support the loadings imposed by the waste disposal operation without settling that causes or contributes to the failure of the leachate collection system

- the liner is constructed from materials whose properties are not affected by contact with the constituents of the leachate expected to be produced.

(NOTE: Alternative specifications, using standard construction techniques, for

hydraulic conductivity and liner thickness may be utilized under the following conditions:

- the liner thickness will be no less than 1.52 m (5 ft) unless a composite liner consisting of a geomembrane immediately overlying a compacted earth liner is installed that meets the following minimum standards:

- the geomembrane is no less than 60 mils in thickness - the compacted earth liner is no less than 0.91 m in thickness (3 ft)

- the modified liner operates in conjunction with a leachate drainage and collection system to achieve equivalent or superior performance to these requirements, as evaluated at maximum annual leachate flow conditions.)

Verify that geomembrane liners are used only in conjunction with a compacted earth liner system and a leachate drainage and collection system, and meet the following standards:

- the geomembrane is supported by a compacted base free from sharp objects - the geomembrane is chemically compatible with the supporting soil materials - the geomembrane material is compatible with the leachate expected to be

generated - geomembranes have sufficient strength and durability to function at the site

for the design period under the maximum expected loadings imposed by the waste and equipment and stresses imposed by settlement, temperature, construction, and operation

- seams are made in the field according to the manufacturer's specifications - all sections are arranged so that the use of field seams is minimized and

seams are oriented in the direction subject to the least amount of stress - the leachate collection system are designed to avoid loss of leachate through

openings in the geomembrane.

Page 230: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-52 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that slurry trenches and cutoff walls built to contain leachate migration are used only in conjunction with a compacted earth liner and a leachate drainage system or as part of a remedial action, and meet the following standards:

- slurry trenches and cutoff walls extend into the bottom confining layer to a depth that will establish and maintain a continuous hydraulic connection and prevent seepage

- exploration borings are drilled along the route of the slurry trench or cutoff wall to confirm the depth to the confining layer

- in situ tests are conducted to determine the hydraulic conductivity of the confining layer

- slurry trenches and cutoff walls are stable under all conditions during the design period of the facility, and will not be susceptible to displacement or erosion under stress or hydraulic gradient

- slurry trenches and cutoff walls are constructed in conformance to a con-struction quality assurance plan that ensures that all material and construction methods meet design specifications.

(NOTE: The owner/ operator may utilize liner configurations other than those

specified, special construction techniques, and admixtures, provided that: - the alternative technology or material provides equivalent, or superior,

performance to these requirements - the technology or material has been successfully utilized in at least one

application similar to the proposed application - methods for manufacturing quality control and construction quality assurance

can be implemented.)

SO.135.27.IL. Leachate drainage systems at putrescible and chemical waste landfills must meet specific standards (35 IAC 811.307).

Verify that the leachate drainage system is designed and constructed to operate for the entire design period.

Verify that the system is designed, in conjunction with the required leachate collection system:

- to maintain a maximum head of leachate 0.30 m (1 ft) above the liner - to operate during the month when the highest average monthly precipitation

occurs and if the liner bottom is located within the saturated zone, under the condition that the groundwater table is at its seasonal high level.

Verify that a drainage layer overlays the entire liner system that is no less than

0.30 m (1 ft) thick, has a hydraulic conductivity equal to or greater than 1x10-3

cm/sec, and is designed to maintain laminar flow throughout the drainage layer under the conditions described in the preceding paragraph.

Verify that the drainage layer is designed with a graded filter or geotextile as necessary to minimize clogging and prevent intrusion of fine material.

Verify that materials used in the leachate collection system are chemically resistant

Page 231: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-53 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

to the wastes and the leachate expected to be produced.

SO.135.28.IL. Leachate collection systems at putrescible and chemical waste landfills must meet specific standards (35 IAC 811.308).

Verify that the leachate collection system is designed and constructed to function for the entire design period.

Verify that collection pipes are designed for open channel flow to convey leachate during the month when the highest average monthly precipitation occurs and if the liner bottom is located within the saturated zone, under the condition that the groundwater table is at its seasonal high level.

Verify that collection pipes are of a cross sectional area that allows cleaning.

Verify that materials used in the leachate collection system are chemically resistant to the leachate expected to be produced.

Verify that the collection pipe material and bedding materials as placed possess structural strength to support the maximum loads imposed by the overlying materials and equipment used at the facility.

Verify that collection pipes are construed within a course gravel envelope using a graded filter or geotextile as necessary to minimize clogging.

Verify that the system is equipped with a sufficient number of manholes and cleanout risers to allow cleaning and maintenance of all pipes throughout the design period.

Verify that leachate is able to drain freely from the collection pipes.

(NOTE: If sumps are used, then pumps must remove the collected leachate before the level of leachate in the sumps rises above the invert of the collection pipes during the month when the highest average monthly precipitation occurs and, if the liner bottom is located within the saturated zone, under the condition that the groundwater table is at its seasonal high level.

SO.135.29.IL. Leachate treatment and disposal sys-tems at putrescible and chemical waste landfills must meet specific standards (35 IAC 811.309(a) through (d)) [Revised May 1999].

Verify that leachate is allowed to flow freely from the drainage and collection system.

(NOTE: The operator is responsible for the operation of a leachate management system designed to handle all leachate as it drains from the collection system. The leachate management system will consist of any combination of storage, treatment, pretreatment, and disposal options designed and constructed in compliance with the requirements of this Section.)

Verify that the on-site treatment or pretreatment system is designed in accordance

Page 232: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-54 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

with the expected characteristics of the leachate.

(NOTE: The design may include modifications to the system necessary to accommodate changing leachate characteristics.)

Verify that the on-site treatment or pretreatment system is designed to function for the entire design period.

Verify that all of the facility's unit operations, tanks, ponds, lagoons, and basins are designed and constructed with liners or containment structures to control seepage to groundwater.

Verify that all treated effluent discharged to waters of the State meet the ground water quality requirements.

Verify that the treatment system is operated by a certified operator.

Verify that the leachate storage facility is able to store a minimum of at least 5 days' worth of accumulated leachate.

(NOTE: A facility may have less than 5 days' worth of storage capacity for accumulated leachate if the owner or operator of the facility demonstrates that multiple treatment, storage and disposal options in the facility's approved leachate management system will achieve equivalent performance.)

Verify that all leachate storage tanks are equipped with secondary containment systems equivalent to the protection provided by a clay liner 0.61 m (2 ft thick) having a permeability no greater than 10-7 cm/sec.

Verify that leachate storage systems are fabricated from material compatible with the leachate expected to be generated and resistant to temperature extremes.

Verify that the leachate storage system does not cause or contribute to a malodor.

Verify that the leachate drainage and collection system is not used for the purpose of storing leachate.

SO.135.30.IL. Discharge of leachate to an off-site treatment works must meet specific minimum standards (35 IAC 811.309(e)).

Verify that, if leachate is discharged to an off-site treatment works, the treatment works meets the following standards:

- all discharges of effluent from the treatment works meet the requirements of 35 Ill. Adm. Code 309

- the treatment system is operated by an operator certified under the requirements of 35 Ill. Adm. Code 312

- no more than 50 percent of the average daily influent flow can be attributable to leachate from the solid waste disposal facility (otherwise, the treatment works is considered a part of the solid waste disposal facility)

Page 233: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-55 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- pumps, meters, valves, and monitoring stations that control and monitor the flow of leachate from the unit and which are under the control of the operator are considered part of the facility and are accessible to the operator at all times

- leachate is allowed to flow into the sewage system at all times; however, if access to the treatment works is restricted or anticipated to be restricted for longer than 5 days, then an alternative leachate management system must be constructed

- where leachate is not directly discharged into a sewerage system, the operator provides storage capacity sufficient to transfer all leachate to an off-site treat-ment works.

(NOTE: The operator is responsible for securing permission from the off-site

treatment works for authority to discharge to the treatment works.)

SO.135.31.IL. Leachate recycling systems at putrescible and chemical waste landfills must meet specific standards (35 IAC 811.309(f)).

Verify that leachate recycling systems are utilized only at permitted waste disposal units that meet the following requirements:

- the unit must have a liner designed, constructed, and maintained to meet the minimum standards of these regulations

- the unit must have a leachate collection system in place and operating in accordance with these regulations

- a gas management system, equipped with a mechanical device such as a com-pressor to withdraw gas, must be implemented to control odors and prevent migration of methane

- the topography must be such that any accidental leachate runoff can be con-trolled by ditches, berms or other equivalent control means.

Verify that leachate is not recycled during precipitation events or in volumes large

enough to cause runoff or surface seeps.

Verify that the amount of leachate added to the unit does not exceed the ability of the waste and cover soils to transmit leachate flow downward.

(NOTE: All other leachate must be considered excess leachate, and a leachate management system capable of disposing of all excess leachate must be available.)

Verify that the leachate storage and distribution system is designed to avoid exposure of leachate to air unless aeration or functionally equivalent devices are utilized.

Verify that the distribution system is designed to allow leachate to be evenly distributed beneath the surface over the recycle area.

Verify that daily and intermediate cover are permeable to the extent necessary to prevent the accumulation of water and formation of perched watertables and gas

Page 234: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-56 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

buildup; alternatively, cover may be removed prior to additional waste placement.

Verify that daily and intermediate cover slopes away from the perimeter of the site to minimize surface discharges.

SO.135.32.IL. Leachate at putrescible and chemical waste landfills must be monitored (35 IAC 811.309(g)) [Revised May 1999].

Verify that representative samples of leachate are collected from each established leachate monitoring location and tested at a frequency of once per quarter until samples have been obtained and tested for at least eight quarters, after which the frequency of testing is changed to semi-annual for any monitored constituent while the leachate management system is in operation.

(NOTE: If for any reason insufficient leachate is obtained to yield a sample for testing during a given quarterly monitoring attempt, such attempt does not count toward the eight quarters' leachate monitoring requirement.)

(NOTE: The frequency of testing may be changed to once per year for any monitored constituent, if it is not detected in the leachate. However, if such a constituent is detected in the leachate, testing frequency must be done on the quarterly schedule.)

Verify that discharges of leachate from units that dispose of putrescible wastes are tested for the following constituents prior to treatment or pretreatment:

- 5 day biochemical oxygen demand (BOD5) - chemical oxygen demand - total suspended solids - total iron - pH - any other constituents listed in the operator's National Pollution Discharge

Elimination System (NPDES) discharge permit or required by a publicly owned treatment works

- all of the indicator constituents used by the operator for groundwater monitoring.

(NOTE: Discharges of leachate from units which dispose only chemical wastes are

monitored for constituents determined by the characteristics of the chemical waste to be disposed of in the unit. They will include, as a minimum:

- total suspended solids - pH - any other constituents listed in the operator's NPDES discharge permit or

required by a publicly owned treatment works - all of the indicator constituents used by the operator for groundwater

monitoring.)

SO.135.33.IL. All Verify that gas monitoring devices are placed at intervals and elevations within the

Page 235: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-57 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

putrescible waste landfills must meet specific gas monitoring requirements (35 IAC 811.310) [Revised May 1999].

waste to provide a representative sampling of the composition and buildup of gases within the unit.

Verify that gas monitoring devices are placed around the unit at locations and elevations capable of detecting migrating gas from the ground surface to the lowest elevation of the liner system or the top elevation of the groundwater, whichever is higher.

(NOTE: A predictive gas flow model may be utilized to determine the optimum placement of monitoring points required for making observations and tracing the movement of gas.)

Verify that gas monitoring devices are constructed from materials that will not react with or be corroded by the landfill gas.

Verify that gas monitoring devices are designed and constructed to measure pressure and allow collection of a representative sample of gas.

Verify that gas monitoring devices are constructed and maintained to minimize gas leakage.

Verify that gas monitoring system does not interfere with the operation of the liner, leachate collection system or delay the construction of the final cover system.

Verify that at least three ambient air monitoring locations are chosen and samples are taken no higher than 0.025 m (1 in.) above the ground and 30.49m (100 f t) downwind from the edge of the unit or at the property boundary, whichever is closer to the unit.

Verify that all gas monitoring devices, including the ambient air monitors, are operated to obtain samples on a monthly basis for the entire operating period and for a minimum of five years after closure.

(NOTE: After a minimum of 5 yr after closure, monitoring frequency may be reduced to quarterly sampling intervals. The sampling frequency may be reduced to yearly sampling intervals upon the installation and operation of a gas collection system equipped with a mechanical device such as a compressor to withdraw gas.)

Verify that monitoring is continued for a minimum period of:

- 30 yr after closure at MSWLF units, except as otherwise provided below - 5 yr after closure at landfills, other than MSWLF units, which are used exclu-

sively for disposing of wastes generated at the site - 15 yr after closure at all other landfills.

Verify that all below ground monitoring devices are monitored for the following parameters at each sampling interval:

Page 236: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-58 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- methane - pressure - oxygen - carbon dioxide.

(NOTE: Ambient air monitors will be sampled for methane only when the average wind velocity is less than 8 kg (5 mi) per hour at a minimum of three downwind locations 30.49 m (100 ft) from the edge of the unit or the property boundary, whichever is closer to the unit.)

Verify that all buildings within a facility are monitored for methane by utilizing continuous detection devices located at points where methane might enter the building.

SO.135.34.IL. Operators of putrescible waste landfills must install a gas management system under certain conditions (35 IAC 811.311(a) and (b)).

Verify that a gas management system is installed if any one of the following condi-tions exist:

- a methane concentration greater than 50 percent of the lower explosive limit in air is detected below the ground surface by a monitoring device or is detected by an ambient air monitor located at or beyond the property boundary or 30.5 m (100 ft) from the edge of the unit, whichever is less, unless the operator can demonstrate that the detected methane concentration is not attributable to the facility

- methane is detected at a concentration greater than 25 percent of the lower explosive limit in air in any building on or near the facility, unless the operator can demonstrate that the detected methane concentration is not attributable to the facility

- malodors caused by the unit are detected beyond the property boundary - leachate is recycled in accordance with regulations.

Verify that, if methane gas levels exceed the limits specified above, the owner or operator of a MSWLF unit:

- notifies the Agency in writing, within 2 business days, of an observed exceedance

- implements the requirements of this Section to ensure the protection of human health.

SO.135.35.IL. Putrescible waste landfills gas management system must met specific requirements (35 IAC 811.311(c) and (d)).

Verify that gas venting systems is utilized only as optional, temporary mitigation until the completion of an active system, and that it meets the following standards:

- all materials are resistant to chemical reaction with the constituents of the gas - the system is capable of venting all gas down to the water table or bottom of

the liner, whichever is higher - gas venting systems are installed only outside the perimeter of the unit.

Page 237: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-59 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that the gas collection system transports gas to a central point or points for

processing for beneficial uses or disposal.

Verify that the gas collection system is designed to function for the entire design period (the design may include changes in the system to accommodate changing gas flow rates or compositions).

Verify that all materials and equipment used in construction of the system are rated by the manufacturer as safe for use in hazardous or explosive environments and are resistant to corrosion by constituents of the landfill gas.

Verify that the gas collection system is designed and constructed to withstand all landfill operating conditions, including settlement.

Verify that provisions are made for collecting and draining gas condensate to a management system meeting the requirements for leachate collection.

Verify that, under no circumstances, does the gas collection system compromise the integrity of the liner, leachate collection or cover systems.

Verify that the portion of the gas collection system, used to convey the gas collected from one or more units for processing and disposal, is tested to be airtight to prevent the leaking of gas from the collection system or entry of air into the system.

Verify that the gas collection system is operated until the waste has stabilized enough to no longer produce methane in quantities that exceed the minimum allowable concentrations.

Verify that the gas collection system is equipped with a mechanical device, such as a compressor, capable of withdrawing gas, or be designed so that a mechanical device can be easily installed at a later time, if necessary, to meet these requirements.

SO.135.36.IL. Putrescible and chemical waste landfills must meet standards for intermediate cover (35 IAC 811.313).

Verify that all waste which is not to be covered within 60 days of placement by another lift of waste or final cover has a cover equivalent to that provided by 0.30 m (1 ft) of compacted clean soil material.

Verify that all areas with intermediate cover are graded so as to facilitate drainage of runoff and minimize infiltration and standing water.

Verify that the grade and thickness of intermediate cover is maintained until the placement of additional wastes or the final cover, and that all cracks, rills, gullies, and depressions are repaired to prevent access to the solid waste by vectors, to minimize infiltration, and to prevent standing water.

Page 238: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-60 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.135.37.IL. Putrescible and chemical waste landfills must meet standards for final cover (35 IAC 811.314) [Revised May 1998].

Verify that the unit is covered by a final cover consisting of a low permeability layer overlain by a final protective layer.

Verify that, not later than 60 days after placement of the final lift of solid waste, a low permeability layer is constructed that covers the entire unit and connects with the liner system.

Verify that, not later than 60 days after placement of the final lift of solid waste, a low permeability layer is constructed consists of any one of the following:

- a compacted earth layer constructed in accordance with the following standards:

- the minimum allowable thickness is 0.91 m (3 ft) - the layer is compacted to achieve a permeability of 1 x 10-7 cm/sec and

minimize void spaces - alternative specifications provided that the performance of the low

permeability layer is equal to or superior to the performance of a layer meeting these requirements

- a geomembrane constructed in accordance with the following standards: - the geomembrane provides performance equal or superior to the

compacted earth layer described above - the geomembrane has strength to withstand the normal stresses imposed

by the waste stabilization process - the geomembrane is placed over a prepared base free from sharp

objects and other materials which may cause damage. - any other low permeability layer construction techniques or materials, pro-

vided that they provide equivalent or superior performance to the require-ments of this subsection.

(NOTE: For a MSWLF unit, if the bottom liner system permeability is lower than

1 x 10-7 cm/sec, the permeability of the low permeability layer of the final cover system will be less than or equal to the permeability of the bottom liner system.)

Verify that the final protective layer covers the entire low permeability layer.

Verify that the thickness of the final protective layer is sufficient to protect the low permeability layer from freezing and minimize root penetration of the low permeability layer, but is not less than 0.91 m (3 ft).

Verify that the final protective layer consists of soil material capable of supporting vegetation.

Verify that the final protective layer is placed as soon as possible after placement of the low permeability layer to prevent desiccation, cracking, freezing or other damage to the low permeability layer.

Page 239: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-61 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.135.38.IL. Drill holes at landfills must be plugged when no longer in use (35 IAC 811.316).

Verify that all drill holes, including exploration borings that are not converted into monitoring wells, monitoring wells that are no longer necessary to the operation of the site, and other holes that may cause or facilitate contamination of groundwater are sealed in accordance with the following standards:

- if not sealed or plugged immediately, the drill hole is covered to prevent injury to people or animals

- all drill holes no longer intended for use are back-filled with materials that are compatible with the geochemistry of the site and with the leachate in sufficient quantities and in such a way as to prevent the creation of a pathway for contaminants to migrate

- for drill holes in gravels and other permeable strata where a watertight seal is not necessary to prevent the creation of a pathway, drill cuttings and other earthen materials may be utilized as backfill

- all excess drilling mud, oil, drill cuttings, and any other contaminated materials uncovered during or created by drilling is disposed of hazardous waste, special waste, and solid waste regulations

- the operator restores the area around the drill hole to its original condition.

SO.135.39.IL. Sources of discharges to groundwater at landfills must be monitored (35 IAC 811.318(a)).

Verify that all potential sources of discharges to groundwater within the landfill facility, including, but not limited to, all waste disposal units and the leachate management system, are identified and studied through a network of monitoring wells operated during the active life of the unit and for the time after closure required by regulation.

Verify that monitoring wells designed and constructed as part of the monitoring network are maintained along with records that include, but are not limited to, exact well location, well size, type of well, the design and construction practice used in its installation and well and screen depths.

SO.135.40.IL. Monitoring points at landfills must be located according to specific criteria (35 IAC 811.318(b)).

Verify that a network of monitoring points is established at sufficient locations down gradient with respect to groundwater flow and not excluding the downward direction, to detect any discharge of contaminants from any part of a potential source of discharge.

Verify that monitoring wells are located in stratigraphic horizons that could serve as contaminant migration pathways.

Verify that monitoring wells are established as close to the potential source of dis-charge as possible without interfering with the waste disposal operations, and within half the distance from the edge of the potential source of discharge to the edge of the zone of attenuation down gradient, with respect to groundwater flow,

Page 240: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-62 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

from the source.

(NOTE: The network of monitoring points of several potential sources of discharge within a single facility may be combined into a single monitoring network, provided that discharges from any part of all potential sources can be detected.)

Verify that a minimum of one monitoring well is established at the edge of the zone of attenuation and located down gradient from the unit with respect to groundwater flow and not excluding the downward direction.

SO.135.41.IL. The landfill groundwater monitoring program must meet specific standards for analysis (35 IAC 811.318(e)).

Verify that the groundwater monitoring program includes consistent sampling and analysis procedures to assure that monitoring results can be relied upon to provide data representative of groundwater quality in the zone being monitored.

Verify that the operator utilizes procedures and techniques to ensure that collected samples are representative of the zone being monitored and that prevent cross con-tamination of samples from other monitoring wells or from other samples (at least 95 percent of a collected sample consists of groundwater from the zone being monitored).

Verify that the operator establishes a quality assurance program that provides quantitative detection limits and the degree of error for analysis of each chemical constituent.

Verify that the operator establishes a sample preservation and shipment procedure that maintains the reliability of the sample collected for analysis.

Verify that the operator institutes a chain of custody procedure to prevent tampering and contamination of the collected samples prior to completion of analysis.

Verify that, at a minimum, the operator samples the following parameters at all wells at the time of sample collection and immediately before filtering and preserving samples for shipment:

- the elevation of the water table - the depth of the well below ground - pH - the temperature of the sample - special conductance.

SO.135.42.IL. Putrescible and chemical waste landfills must implement a

Verify that the operator implements a detection monitoring program that begins as soon as waste is placed into the unit of a new landfill or by 23 June 1999 for an existing landfill.

Page 241: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-63 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

groundwater monitoring program (35 IAC 811.319(a)(1)) [Revised May 1999].

existing landfill.

Verify that monitoring continues for a minimum period of 15 yr after closure, or in the case of MSWLF units, a minimum period of 30 yr after closure (except as otherwise provided below).

Verify that the operator samples all monitoring points for all potential sources of contamination on a quarterly basis for a period of 5 yr from the date of issuance of the initial permit, after which the sampling frequency for each monitoring point will be on a semi-annual basis.

(NOTE: Beginning 15 yr after closure of the unit, or 5 yr after all other potential sources of discharge no longer constitute a threat to groundwater, the monitoring frequency may change on a well by well basis to an annual schedule if either of the following conditions exist:

- all constituents monitored within the zone of attenuation have returned to a concentration less than or equal to ten percent of the maximum allowable predicted concentration

- all constituents monitored within the zone of attenuation are less than or equal to their maximum allowable predicted concentration for eight consecutive quarters.)

Verify that monitoring is continued for a minimum period of:

- 30 yr after closure at MSWLF units - 5 yr after closure at landfills, other than MSWLF units, which are used exclu-

sively for disposing waste generated at the site - 15 yr after closure at all other landfills.

(NOTE: Monitoring, beyond the minimum period, may be discontinued under the following conditions:

- no statistically significant increase is detected in the concentration of any constituent above that measured and recorded during the immediately preceding scheduled sampling for 3 consecutive years, after changing to an annual monitoring frequency; or

- immediately after contaminated leachate is no longer generated by the unit.)

SO.135.43.IL. The groundwater monitoring program must include specific constituents to be monitored (35 IAC 811.319(a)(2)).

Verify that the operator monitors each well for constituents that will provide a means for detecting groundwater contamination; constituents are to be chosen for monitoring if they meet the following requirements:

- the constituent appears in, or is expected to be in, the leachate, and - the Board has established for the constituent a public or food processing

water supply standard, at 35 Ill. Adm. Code 302, the Board has established a groundwater quality standard under the Illinois Groundwater Protection Act (Ill. Rev. Stat. 1991, ch. 111 1/2, par. 7451 et seq. [415 ILCS 55/1 et seq.]), or the constituent may otherwise cause or contribute to groundwater

Page 242: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-64 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

contamination.

(NOTE: One or more indicator constituents, representative of the transport processes of constituents in the leachate, may be chosen for monitoring in place of the constituents it represents. The use of such indicator constituents must be included in an Agency approved permit.)

Verify that the operator monitors each existing well that is being used as a part of the monitoring well network and monitors each new well within 3 mo of its establishment, for a broad range of organic chemical contaminants in accordance with an analysis that is at least as comprehensive and sensitive as the tests for:

- the 51 organic chemicals in drinking water described at 40 CFR 141.40 (1988), incorporated by reference at 35 Ill. Adm. Code 810.104, and

- any other organic chemical for which a groundwater quality standard of criterion has been adopted by the state

- at least once every two years, the operator monitors each well.

SO.135.44.IL. Groundwater quality must be maintained at or beyond the zone of attenuation (35 IAC 811.320(a)).

Verify that groundwater quality is maintained at each constituent's background concentration, at or beyond the zone of attenuation.

(NOTE: The applicable groundwater quality standard established for any constituent is:

- the background concentration, or - the Board established standard adjusted by the Board.)

SO.135.45.IL. Waste dis-posal operations at putrescible and chemical waste landfills must be conducted according to specific requirements (35 IAC 811.321) [Revised May 1999].

Verify that waste disposal operations move from the lowest portions of the unit to the highest portions.

(NOTE: The operator may dispose of wastes in areas other than those specified above only under any of the following conditions:

- climatic conditions, such as wind and precipitation, are such that the placement of waste in the bottom of the unit would cause water pollution, litter, or damage to any part of the liner

- the topography of the land surrounding the unit makes the procedure above environmentally unsound, for example, because steep slopes surround the unit

- when groundwater monitoring wells are placed 50 ft, or less, down gradient from the filled portions of the unit.)

Verify that construction, compaction and earth moving equipment do not operate

directly on the leachate collection piping system until a minimum of 5 ft of waste has been mounded over the system.

Verify that construction, compaction and earth moving equipment do not operate

Page 243: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-65 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

directly on the leachate drainage blanket.

Verify that waste disposal operations begin at the edge of the drainage layer by carefully pushing waste out over the drainage layer.

Verify that an initial layer of waste, a minimum of 5 ft thick, or, alternatively, a temporary protective layer of other material suitable to prevent the compacted earth liner from freezing, is placed over the entire drainage blanket prior to the onset of weather conditions that may cause the compacted earth liner to freeze.

Verify that waste is not placed over areas that are subject to freezing conditions until the liner has been certified or recertified by the CQA officer and reconstructed (if necessary) to meet requirements.

SO.135.46.IL. Putrescible and chemical waste landfills must meet specific standards for final slope and stabilization (35 IAC 811.322).

Verify that all final slopes are designed and constructed to a grade capable of supporting vegetation and minimizes erosion.

Verify that all slopes are designed to drain runoff away from the cover and which prevents ponding (no standing water may be allowed anywhere in or on the unit).

Verify that vegetation:

- is promoted on all reconstructed surfaces to minimize wind and water erosion of the final protection cover

- is compatible with the climatic conditions - requires little maintenance - consists of a diverse mix of native and introduced species that is consistent

with the postclosure land use - is tolerant of the landfill gas expected to be generated - has root depth that does not exceed the depth of the final protective cover

system.

Verify that temporary erosion control measures, including but not limited to mulch straw, netting and chemical soil stabilizers, are undertaken while vegetation is being established.

Verify that structures constructed over the unit are compatible with the land use, designed to vent gases away from the interior, and in no way interfere with the operation of a cover system, gas collection system, leachate collection system or any monitoring system.

SO.135.47.IL. Putrescible and chemical waste landfills must implement a load checking program to detect

Verify that the operator implements a load checking program for detecting and dis-couraging attempts to dispose regulated hazardous wastes at the facility.

Verify that the load checking program consists of, at a minimum, the following

Page 244: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-66 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

hazardous waste in incoming loads (35 IAC 811.323).

components:

- an inspector designated by the facility examines at least three random loads of solid waste delivered to the landfill on a random day each week

- the drivers randomly selected by the inspector are directed to discharge their loads at a separate, designated location within the facility

- the a detailed inspection of the discharged material is conducted for any regulated hazardous or other unacceptable wastes that may be present.

(NOTE: Cameras or other devices may be used to record the visible contents of

solid waste shipments. Where such devices are employed, their use should be designated on a sign posted near the entrance to the facility.)

Verify that information and observations derived from each random inspection are recorded in writing and retained at the facility for at least 3 yr, and that the recorded information includes, at a minimum:

- the date and time of the inspection - the names of the hauling firm and the driver of the vehicle - the vehicle license plate number - the source of the waste, as stated by the driver - observations made by the inspector during the detailed inspection.

Verify that the written record is signed by both the inspector and the driver.

Verify that, if regulated hazardous wastes or other unacceptable wastes are suspected, the facility communicates with the generator, hauler, or other party responsible for shipping the waste to determine the identity of the waste.

Verify that designated inspectors, equipment operators, weigh station attendants, spotters at large facilities, and all other appropriate facility personnel are trained in the identification of potential sources of regulated hazardous wastes and other unacceptable wastes, including but not limited to PCBs.

(NOTE: The training program must emphasize familiarity with containers typically used for regulated hazardous wastes and with labels for regulated hazardous wastes, under RCRA, and for hazardous materials under the Hazardous Materials Transportation Act (49 U.S.C. 1801 et seq.).)

Verify that, if any regulated hazardous wastes are identified by random load checking, or are otherwise discovered to be improperly deposited at the facility:

- the facility promptly notifies the Agency, the person responsible for shipping the wastes to the landfill, and the generator of the wastes, if known

- waste loads identical to the regulated hazardous waste identified through the random load checking which have not yet been deposited in the landfill are not accepted

- the area where the wastes are deposited is immediately cordoned off from public access

Page 245: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-67 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- the solid waste management facility assures the cleanup, transportation and disposal of the waste to a permitted hazardous waste management facility.

(NOTE: The party responsible for transporting the waste to the solid waste management facility is responsible for the costs of such proper cleanup, transportation, and disposal.)

Verify that subsequent shipments by persons or sources found or suspected to be previously responsible for shipping regulated hazardous waste are subject to the following special precautionary measures prior to the solid waste management facility accepting wastes: questioning the driver concerning the waste contents prior to discharge and visual inspection during the discharge of the load at the working face or elsewhere.

Page 246: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-68 Solid Waste Management

Page 247: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-69 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.140. CONSTRUCTION/ DEMOLITION LANDFILLS

SO.140.1.IL. Inert waste landfills meet specific final cover requirements (35 IAC 811.204 and 811.205).

Verify that a minimum of 0.91 m (3 ft) of soil material that will support vegetation is applied over all disturbed areas.

(NOTE: Where no vegetation is required for the intended postclosure land use, the final surface must still be designed to prevent or minimize erosion.)

Verify that all waste disposal units are designed and constructed to achieve a mini-mum static slope safety factor of 1.5.

Verify that all waste disposal units are designed and constructed to achieve a mini-mum seismic safety factor of 1.3.

Verify that vegetation is promoted on all reconstructed surfaces to minimize wind and water erosion.

Verify that vegetation is compatible with the local climatic conditions and requires little maintenance.

Verify that vegetation consists of a diverse mix of native and introduced species consistent with the postclosure land use.

Verify that temporary erosion control measures, such as the application, alone or in combination, of mulch, straw, netting, or chemical soil stabilizers, are undertaken while vegetation is established.

Verify that the landfill site is monitored for settling for a minimum period of 15 yr after closure.

SO.140.2.IL. Operators of inert landfills are required to conduct leachate sampling (35 IAC 811.206).

Verify that all inert waste landfills are designed to include a monitoring system capable of collecting representative samples of leachate generated by the waste using methods such as pressure-vacuum lysimeter, trench lysimeter, or well point.

Verify that the sampling locations are located so as to collect the least diluted leachate samples.

Verify that leachate samples are collected and analyzed at least once every 6 mo to determine whether the collected leachate is contaminated.

Page 248: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-70 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that leachate samples are tested once every 2 yr for the presence of organic chemicals with the state’s groundwater monitoring criteria.

Verify that, if the results of such testing shows the presence of organic chemicals, the operator notifies the Agency of this finding in writing before the end of the business day following the finding.

Verify that, if the results of testing of leachate samples confirm that the leachate is contaminated, the operator notifies the Agency of this finding in writing before the end of the business day following the finding.

(NOTE: The inert waste landfill facility causing the contamination will be subject to the requirements for Putrescible and Chemical Landfills.)

Verify that the results of the chemical analysis tests are included in the quarterly groundwater reports submitted to the Agency.

SO.140.3.IL. Operators of inert waste landfills must institute and conduct a random load checking program (35 IAC 811.207).

Verify that the operator does not accept waste for disposal at an inert waste landfill unless the waste is accompanied by documentation showing that such wastes are inert based on testing of the leachate from such wastes.

Verify that the operator institutes and conducts a random load checking program at each inert waste facility that is also designed to:

- detect and discourage attempts to dispose non-inert wastes at the landfill - require the facility’s inspector to examine at least one random load of solid

waste delivered to the landfill on a random day each week - require the operator to test one randomly selected waste sample to determine

if the waste is inert.

Verify that the results of the load checking is included in the annual report submitted to the Agency.

Page 249: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-71 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.160. WASTE TIRES FACILITIES

(NOTE: These requirements for used tires do not apply to the following:

- altered tires which have been chopped, shredded, or processed such that the individual dimensions of height, length, and width of the tire product are 2 inches or less

- converted, new, or reprocessed tires - reused tires which have been altered to prevent the accumulation of waste - tire storage or disposal sites where less than 50 used or waste tires are stored - used or waste tires disposed of in landfills permitted by the Agency to receive

them.)

SO.160.1.IL. Tire storage sites and tire disposal sites where more than 50 used or waste tires are located must meet certain operational requirements (35 IAC 848.101 and 848.202 (b)).

Verify that no used or waste tires are placed on or accumulated in any pile outside of any building unless the pile is separated from all other piles by no less than 25 ft, and aisle space is maintained to allow the unobstructed movement of personnel and equipment.

Verify that used or waste tires are not accumulated in any area located outside of any building unless the accumulation is separated from all buildings, whether on or off the site, by no less than 25 ft.

Verify that no used or waste tires are placed on or accumulated in any pile unless the pile is separated from all potential ignition sources, including cutting and welding devices, and open fires, by not less than 250 ft or all such activities are carried out within a building.

Verify that used or waste tires are drained of water on the day of generation or receipt.

Verify that used or waste tires received at the site are not stored unless the used tire is altered, reprocessed, converted, covered, or otherwise prevented from accumulating water within 14 days after.

Verify that used or waste tires are not abandoned, dumped, or disposed of on private or public property except in a permitted landfill.

Verify that used or waste tires are not accepted from a vehicle in which more than 20 tires are loaded unless the vehicle displays a placard issued by the Agency.

Verify that tires are not accumulated in an area if the grade of the ground surface exceeds 2 percent slope unless the area of the site is completely surrounded by an earthen berm or other structure not less than 2 ft in height and capable of containing runoff resulting from tire fires, accessible by fire fighting equipment, and a means of access through or over the berm or structure.

Page 250: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-72 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.160.2.IL. Sites where more than 500 used or waste tires are located must meet additional operational require-ments (35 IAC 848.202 (c)).

(NOTE: These requirements are in addition to those in SO.160.1.IL.)

Verify that used or waste tires are not placed on or accumulated in any pile unless the pile is separated from grass, weeks, brush, over-hanging tree limbs, and similar vegetative growth by no less than 50 ft.

Verify that used or waste tires are not placed on or accumulated in any tire storage unit unless the unit is no more than 20-ft high by 250-ft wide by 250-ft long.

(NOTE: In determining the width or length of any tire storage unit, the aisle space between any piles within the unit is included.)

Verify that used or waste tires are not placed or accumulated in any tire storage unit unless one of the following requirements is met:

- the tire storage unit is separated from all buildings, whether located on or off the site, and all other tire storage units by an earthen berm that is no less than 1.5 times the maximum height of any tire pile within the storage unit

- the tire storage unit is separated from all buildings, whether located on or off the site, and all other tire storage units by a separation distance that is not less than the distance identified by Appendix 7-1.

SO.160.3.IL. Tire storage sites and tire disposal sites where more than 500 used or waste tires are located must have a contingency plan (35 IAC 848.202©(1) and 848.302).

Verify that the site has a contingency plan designed to minimize the hazards to human health and the environment from fires and runoff of contaminates resulting from fires and disease-spreading mosquitoes and other nuisance organisms which may breed in water accumulations in used or waste tires.

Verify that a copy of the contingency plan and all revisions to the plan is maintained at the site and submitted to the local fire departments, police departments, the Agency, and state and local emergency response teams that may be called upon to provide emergency service.

Verify that the provisions of the plan are carried out immediately whenever there is a fire or runoff resulting from tire fire or evidence of mosquitoes production in used or waste tires.

Verify that there is at all times at least one employee, either on the site premises or on call, with responsibility for coordinating all emergency response measures.

SO.160.4.IL. Sites where more than 500 used or waste tires are located must meet specific recordkeeping

Verify that the facility maintains a daily tire record and annual tire summary at the site.

Verify that each annual tire summary is submitted to the Agency, signed by a

Page 251: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-73 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

requirements (35 IAC 848.202©(2), 848.302 and 848.305).

person designated by the facility as responsible for preparing and reviewing such documents.

Verify that copies of all records are retained by the facility for 3 yr and are made available at the site during normal business hours for inspection and photocopying by the Agency.

SO.160.5.IL. Sites where more than 10,000 used or waste tires are located must meet certain operating requirements (35 IAC 848.202 (d)).

Verify that the area of the site where used or waste tires are stored is completely surrounded by fencing in good repair which is not less than 6-ft high.

Verify that the entrance to the area where used or waste tires are located is controlled at all times by an attendant, locked entrance, television monitors, controlled roadway access, or other equivalent mechanisms.

Verify that the area of the site where used or waste tires are stored is completely surrounded by an earthen berm other structure not less than 2 ft [0.61 m] in height, capable of containing runoff resulting from tire fires, and accessible by fire fighting equipment, except that the facility must provide a means for access through or over the berm or other structure.

SO.160.6.IL. Storage of used or waste tires in buildings must meet specific operational standards (35 IAC 848.204).

Verify that used or waste tires are stored within a building only if:

- the tires are drained of all water prior to placement in the building - all of the building’s windows and doors are in working order and are secured

to prevent unauthorized access - the building is fully enclosed and has a roof and sides which are impermeable

to precipitation - the building is not a single family home or a residential dwelling.

Verify that, if 500 or more used or waste tires are stored within a building, the facility:

- develops a tire storage plan in consultation with the local fire department or the state fire marshal

- has and maintains a contingency plan - meets the daily tire record and annual tire summary recordkeeping

requirements.

(NOTE: Buildings constructed after the effective date of these rules (14 February 1992) for the primary purpose of storing more than 10,000 used or waste tires must meet the National Fire Protection Association (NFPA) 231D Standard for Storage of Rubber Tires.)

Page 252: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-74 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.160.7.IL. Owners/ operators of tire storage sites that apply pesticides must meet specific requirements (35 IAC 848.204).

Verify that owners/operators of tire storage sites or tire disposal sites treating used or waste tires with pesticides use a pesticide labeled for control of mosquito larvae unless an adult mosquito problem is identified.

Verify that a record of pesticide use is maintained at the site that includes:

- date of pesticide application - number of used or waste tires treated - amount of pesticide applied - type of pesticide used.

Verify that the owner/operator notifies the Agency of pesticide use within 10 days

of each application, and that the notification includes the information listed above.

(NOTE: Persons applying pesticides to used and waste tires must comply with the requirements of the Illinois Pesticide Act.)

SO.160.8.IL. The trans-portation of used or waste tires requires a permit (35 IAC 848.601 through 848.606).

Verify that when more than 20 used or waste tires are transported, the transportation vehicle has a current, valid registration from the Agency .

Verify that, upon approval, the owner/operator of any vehicle registered to trans-port used or waste tires places a placard on opposite sides of the vehicles which displays a number issued by the Agency following the words “Registered Tire Transporter: (number).”

Verify that the transporter displays a seal furnished by the Agency designating the date on which the registration expires directly adjacent to the words and number of the placard.

Page 253: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-75 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.165. YARD WASTE/ COMPOSTING

(NOTE: The requirements in this section (from Part 830 of Title 35) do not apply to a garden compost operation as defined at Section 830.102.)

SO.165.1.IL. All regulated landscape waste compost facilities must meet minimum performance standards (35 IAC 830.202(a) through (i)).

(NOTE: Onsite landscape waste compost facilities are exempt from these require-ments.)

Verify that the composting material does not contain any domestic sewage, sewage sludge, or septage.

Verify that any bulking agent used which is otherwise a waste, other than landscape waste, is only used as authorized by the Agency in writing or by permit.

Verify that the operator takes specific measures to control odors and other sources of nuisance so as not to cause or contribute to a violation.

Verify that the operator has available for inspection a plan for the intended purposes of end-product compost and a contingency plan for handling end-product compost and composting material that does not meet the general use compost standards.

Verify that the operator has a plan for minimizing odors that includes:

- specifications of a readily-available supply of bulking agents, additives, or odor control agents

- procedures for avoiding delay in processing and managing landscape waste during all weather conditions

- methods for taking into consideration the following factors prior to turning or moving composting material:

- time of day - wind direction - percent moisture - estimated odor potential - degree of maturity.

Verify that landscape waste is processed within 5 days after receipt into windrows or other piles which promote proper conditions for composting.

(NOTE: Incoming leaves, brush or woody landscape waste may be stored in desig-nated areas for use as a carbon source and bulking agent, rather than being processed into windrows or other piles.)

Verify that the facility is designed and constructed so that runon is diverted around the composting area, and that the runoff from the facility resulting from

Page 254: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-76 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

precipitation less than or equal to the 10 yr, 24 hr precipitation event is controlled so as not to cause or contribute to a violation.

Verify that the facility is constructed and maintained to have an accessible clear space between windrows or other piles, suitable for housekeeping operations, visual inspection of piling areas and fire fighting operations.

Verify that, except for on-farm landscape waste compost facilities, the operator posts permanent signs at each entrance, the text of which specifies in letters not less than 3 in. high:

- the name and mailing address of the operation - the operating hours - materials which can be accepted - the statement, COMPLAINTS CONCERNING THIS FACILITY CAN BE

MADE TO THE FOLLOWING PERSONS, followed by the name and tele-phone number of the operator, and the name and telephone number of the Bureau of Land, Illinois Environmental Protection Agency, Springfield, Illinois.

SO.165.2.IL. All regulated landscape waste compost facilities must meet specific reporting requirements (35 IAC 830.202(k)).

Verify that the operator of any facility required to have a permit submits a written annual statement to the Agency, on a form provided by the Agency, on or before 1 April of each year that includes:

- an estimate of the amount of material, in tons, received for composting in the previous calendar year

- an estimate of the amount and disposition of compost material (i.e., end-product compost, chipped/shredded brush) in the previous calendar year

- a Composting Facility Financial Assurance Plan Compliance Certification.

Verify that for any permit-exempt facility with over 100 cubic yards of composting material on-site at one time, files a report by 1 April of each year with the Agency, on a form provided by the Agency, stating, at a minimum:

- the facility location - an estimate of the amount of material, in cubic yards or tons, received for

composting in the previous calendar year - the total amount of end-product compost still on-site, used or sold during the

previous calendar year.

SO.165.3.IL. All regulated landscape waste compost facilities must meet specific closure requirements (35 IAC

Verify that, unless otherwise authorized in a facility permit, all landscape waste, composting material, end-product compost, and additives are removed from the facility within 180 days following the beginning of closure.

Page 255: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-77 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

830.202(l)). Verify that an operator of a facility closes the facility in a manner which:

- minimizes the need for further maintenance - controls, minimizes or eliminates the release of landscape waste, landscape

waste constituents, landscape waste leachate, and composting constituents to the groundwater or surface waters or to the atmosphere to the extent necessary to prevent threats to human health or the environment.

Verify that, by 1 April of the year following completion of closure, the operator of

any permit-exempt facility with over 100 cubic yards of composting material on-site at one time files a report with the Agency verifying that closure was completed in accordance with this Section in the previous calendar year.

SO.165.4.IL. All regulated landscape waste compost facilities must take certain steps in response to an odor complaint (35 IAC 830.202(m)).

Verify that, except for on-farm landscape waste compost facilities, for every odor complaint received, the operator:

- records and reports to the Agency within 24 hr after receiving the complaint, the date and time received, the name of complainant, the address and phone number of complainant, if volunteered upon request, and the name of the personnel receiving the complaint

- records the date, time, and nature of any action taken in response to an odor complaint, and reports such information to the Agency within 7 days after the complaint.

SO.165.5.IL. Landscape waste compost facilities must meet location standards (35 IAC 830.203).

Verify that, with the exception of on-farm landscape waste operations, all landscape waste compost facilities comply with the following:

- the composting area of the facility includes a setback of at least 200 ft from the nearest potable water supply well

- the composting area of the facility is located outside the boundary of the 10-yr floodplain or the site must be floodproofed

- the composting area of the facility is located so as to minimize incompatibility with the character of the surrounding area, including at least a 200 foot setback from any residence.

- in the case of a facility that was developed or the permitted composting area of which was expanded after 17 November 1991, the composting area is located at least 1/8 mile from the property line of each of the following:

- facilities that primarily serve to house or treat people that are immunocompromised or immunosuppressed, such as cancer or AIDS patients; people with asthma, cystic fibrosis, or bioaerosol allergies; or children under the age of 1 yr

- primary and secondary schools and adjacent areas that the school uses for recreation, and

- any facility for child care licensed under Section 3 of the Child Care Act of 1969; preschools; and adjacent areas that the facility or preschool

Page 256: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-78 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

uses for recreation.

(NOTE: If, at the time the facility permit application is deemed complete by the Agency, the composting area of the facility is located within 1/4 mi of the nearest off-site residence or within 1/2 mi of the nearest platted subdivision containing a residence, or if more than 10 residences are located within 1/2 mi of the boundaries of the facility, in order to minimize incompatibility with the character of the surrounding area, landscape waste must be processed by the end of the operating day on which the landscape waste is received into windrows, other piles or a contained composting system providing proper conditions for composting.)

Verify that the composting area of the facility is designed to prevent any compost material from being placed within 5 ft of the water table, to adequately control runoff from the site, and to collect and manage any landscape waste leachate that is generated on the site.

(NOTE: Compliance with the water table distance requirement may be demonstrated by either of the following means:

- using published water table maps or other published documentation to establish the location of the water table in relation to site elevation, or

- actual measuring of the water table elevation at least once per month for three consecutive months.)

Verify that the facility meets all requirements under the Wild and Scenic Rivers

Act (16 U.S.C. 1271 et seq.).

Verify that the facility does not restrict the flow of a 100-yr flood, result in washout of landscape waste from a 100-yr flood, or reduce the temporary water storage capacity of the 100-yr floodplain, unless measures are undertaken to provide alternative storage capacity, such as lagoons, holding tanks, or provision of drainage around structures at the facility.

Verify that the facility is not located in any area where it may pose a threat of harm or destruction to the features for which:

- an irreplaceable historic or archaeological site has been listed pursuant to the National Historic Preservation Act (16 U.S.C. 470 et seq.) or the Illinois His-toric Preservation Act [20 ILCS 3410]

- a natural landmark has been designated by the National Park Service or the Illinois State Historic Preservation Office, or

- a natural area has been designated as a Dedicated Illinois Nature Preserve pursuant to the Illinois Natural Areas Preservation Act [525 ILCS 30].

Verify that the facility is not located in any area where it may jeopardize the

continued existence of any designated endangered species, result in the destruction or adverse modification of the critical habitat for such species, or cause or contribute to the taking of any endangered or threatened species of plant, fish or wildlife listed pursuant to the Endangered Species Act (16 U.S.C. 1531 et. seq.),

Page 257: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-79 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

or the Illinois Endangered Species Protection Act [520 ILCS 10].

Quality of End-Product Compost

(NOTE: End-product compost used as daily cover or vegetative amendment in the final layer of a landfill is exempt from these requirements. For the purpose of this subsection, end-product compost must be classified in the following manner:

- general use compost: end-product compost which meets the standards set forth in SO.165.6.IL. below

- designated use compost: end-product compost which does not qualify as general use end-product compost. (Designated use compost must be used only as daily cover or vegetative amendment in the final layer at a landfill).)

SO.165.6.IL. General use compost must meet specific performance standards(35 IAC 830.503).

Verify that the compost free of any materials which pose a definite hazard to human health due to physical characteristics, such as glass or metal shards.

Verify that the compost does not contain man-made materials larger than 4 mm in size exceeding 1 percent of the end-product compost, on a dry weight basis.

Verify that the compost as a pH between 6.5 and 8.5.

Verify that the compost has reached stability.

Verify that the compost does not exceed, on a dry weight basis, the inorganic concentrations found in Appendix 9-2.

Verify that the compost does not contain fecal coliform populations that exceed 1000 MPN per gram of total solids (dry weight basis), or Salmonella species populations that exceed 3 MPN per 4 grams of total solids (dry weight basis).

SO.165.7.IL. End-product compost derived from landscape waste must meet specific testing standards (35 IAC 830.504 and 508).

Verify that operators perform testing to demonstrate compliance with the standards set forth in SO.165.6.IL.

Verify that operators of facilities which are authorized to use an additive which may cause an exceedance of fecal coliforms or Salmonella test for pathogens.

(NOTE: For any facility not required to have a permit, no testing need be done to demonstrate compliance with the inorganics standards in Section 830, Table A (see Appendix 9-2) for general use compost derived from landscape waste.)

Verify that end-product compost derived from landscape waste is tested for the parameters set forth in SO.165.6.IL. at a frequency of:

- once every 5000 yd3 of end-product compost transported off-site - once per year, if less than 5000 yd3 of end-product compost are transported

Page 258: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-80 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

off-site per year.

(NOTE: End-product compost derived from landscape waste which does not meet the standards for general use compost must be further managed as landscape waste or as designated use compost.)

Page 259: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-81 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SO.180. CLOSURE OF SOLID WASTE FACILITIES

SO.180.1.IL. Solid waste management units must be closed in accordance with closure performance standards (35 IAC 807.502).

Verify that the waste management site is closed in a manner which:

- minimizes the need for further maintenance - controls, minimizes, or eliminates postclosure release of waste, waste

constituents, leachate, contaminated rainfall, or waste decomposition products to the groundwater, surface waters, or to the atmosphere to the extent necessary to prevent threats to human health or the environment.

SO.180.2.IL. Solid waste management units must prepare a written closure plan as a condition of the site permit (35 IAC 807.503 (a) and (b)).

Verify that the facility has a written closure plan.

Verify that indefinite storage units have a written contingent closure plan.

SO.180.3.IL. Solid waste management units must provide notice to the Agency prior to closure of a waste management site (35 IAC 807.505).

Verify that the facility sends a notice of closure to the Agency within 30 days after the date the final volume of waste is received at a waste management site for treatment, storage, or disposal.

SO.180.4.IL. Solid waste management units must initiate closure of a waste management site according to certain requirements (35 IAC 807.506 (a) and (c)).

Verify that the facility initiates the treatment, removal of waste from the site, and disposal of all wastes and waste residues, other than those from indefinite storage units, within 30 days after receipt of the final volume of waste and in accordance with the closure plan.

(NOTE: If the facility temporarily suspends waste acceptance, the facility must notify the Agency within 30 days of the suspension and must meet any temporary suspension plan requirements in the permit).

SO.180.5.IL. Solid waste management units must initiate closure of an indefinite

Verify that the facility initiates one of the following courses of action within 30 days after the receipt of the final volume of waste:

Page 260: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-82 Solid Waste Management

COMPLIANCE CATEGORY: SOLID WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

storage unit according to certain requirements (35 IAC 807.506 (b)).

- removal of all waste and waste residues from the unit - closure of the unit in accordance with the contingent closure plan.

SO.180.6.IL. Solid waste management units must submit specific documentation to the Agency when closure of a waste management site is complete (35 IAC 807.508 (a)).

Verify that the facility submits the following documentation when closure of a waste management site is complete:

- plan sheets for the closed site - an affidavit by the operator and by a professional engineer that the site has

been closed in accordance with the closure plan.

SO.180.7.IL. Acceptance of waste after closure has been initiated at a waste management site is restricted (35 IAC 807.509).

Verify that, after closure of a site has been initiated, waste is accepted for disposal or for use in closure and postclosure care only as authorized in the closure and postclosure care plans.

SO.180.8.IL. Solid waste management units must have a postclosure care plan for every waste management site and indefinite storage area and implement the plans upon receipt of the certificate of closure (35 IAC 807.523 and 807.524)

Verify that the facility has a postclosure care plan for every waste management site and a contingent postclosure care plan for every indefinite storage unit.

Verify that the facility implements postclosure care plans and contingent postclosure care plans upon receipt of the certificate of closure.

Page 261: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-83 Solid Waste Management

Appendix 9-1

Separation Distances For Tire Storage Units (in ft)

(Source: 35 IAC 848.202(c)(5)(B))

Tire Storage Unit Heights Unit Face Dimension

8 12 16 20

25 56 67 77 85 50 75 93 107 118

100 100 128 146 164 150 117 149 178 198 200 130 167 198 226 250 140 181 216 245

Page 262: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-84 Solid Waste Management

Page 263: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

9-85 Solid Waste Management

Appendix 9-2

Inorganic Concentration Limits for General Use Compost

(Source: 35 IAC 830, Table A)

Maximum Concentration Limit (mg/kg dryweight basis)

Test Method (SW-846)

Arsenic 41 7060 or 7061 Cadmium 21 7130 or 7131 or 6010 Chromium 1,200 7190 or 7191 or 6010 Copper 1,500 7210 or 7211 or 6010 Lead 300 7420 or 7421 or 6010 Mercury 17 7471 Nickel 420 7520 or 6010 Selenium 36 7740 or 7741 Zinc 2,800 7950 or 7951 or 6010

Page 264: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-1 Storage Tank Management

SECTION 10

STORAGE TANK MANAGEMENT

Illinois Supplement, June 2000 This section covers the Illinois requirements for Storage Tank Management and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements. In Illinois, notifications and reports on underground storage tanks (USTs) must be submitted to the Office of the State Fire Marshal.

Definitions

• Aboveground Storage Tank - a tank used to store or process used oil that is not an underground storage tank (Title 41, Illinois Administrative Code, Section 170.400 (41 IAC 170.400)).

• Bulk Gasoline Plant - any gasoline storage and distribution facility that receives gasoline from bulk gasoline

terminals by delivery vessels and distributes gasoline to gasoline dispensing facilities (35 IAC 211). • Bulk Gasoline Terminal - any gasoline storage and distribution facility that receives gasoline by pipeline, ship,

or barge, and distributes gasoline to bulk gasoline plants or gasoline dispensing facilities (35 IAC 211). • Cathodic Protection - a technique to prevent corrosion of a metal surface by making that surface the cathode of

an electrochemical cell. For example, a tank system can be cathodically protected through the application of either galvanic anodes or impressed current (41 IAC 170.400).

• Chicago Area - the area comprised of Cook, DuPage, Kane, Lake, McHenry and Will Counties and Aux Sable

Township and Goose Lake Township in Grundy County and Oswego Township in Kendall County (35 IAC 218.100) [Added May 1999].

• Container - any portable device in which a material is stored, transported, treated, disposed of, or otherwise

handled (41 IAC 170.400). • Crude Oil - a naturally occurring mixture which consists of hydrocarbons and sulfur, nitrogen, or oxygen

derivatives of hydrocarbons and which is a liquid at standard conditions (35 IAC 211). • Custody Transfer - the transfer of produced petroleum and/or condensate after processing and/or treating in the

producing operations, from storage tanks or automatic transfer facilities to pipelines or any other forms of transportation (35 IAC 211).

• Delivery Vessel - any tank truck or trailer equipped with a storage tank that is used for the transport of gasoline

to a stationary storage tank at a gasoline dispensing facility, bulk gasoline plant, or bulk gasoline terminal (35 IAC 211).

• Dispensing - the transference or a regulated substance from a UST or AST directly into the fuel tank of a motor

vehicle operated by an internal combustion engine or use by that motor vehicle. Also means the transference of a regulated substance from a UST or AST directly into a portable container (41 IAC 170.400).

• Distillate Fuel Oil - fuel oils of grade Number 1 or 2 as specified in detailed requirements for fuel oil in ASTM

D-369-69 (1971) (35 IAC 211).

Page 265: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-2 Storage Tank Management

• Existing Tank System - a tank system used to contain an accumulation of regulated substance or for which

installation has commenced on or before 22 April 1989 (41 IAC 170.400). • Floating Roof - a roof on a stationary tank, reservoir or other container which moves vertically upon change in

volume of the stored material (35 IAC 211). • Gasoline - any petroleum distillate having a Reid vapor pressure of 4 pounds or greater (35 IAC 211). • Gasoline Dispensing Facility - any site where gasoline is transferred from a stationary storage tank to a motor

vehicle gasoline tank used to provide fuel to the engine of that motor vehicle (35 IAC 211). • Heating Oil - petroleum that is No. 1, No. 2, No. 4-light, No. 4-heavy, No. 5-light, No. 5-heavy, or No. 6

technical grades of fuel oil, other than residual fuels oils (including Navy Special fuel oil and Bunker C), and other fuels when used as substitutes for one of these fuel oils. Heating oil is typically used in the operation of heating equipment, boilers, or furnaces (41 IAC 170.400).

• Heating Oil for Consumptive Use on Premises - heating oil consumed exclusively on the premises where the

heating oil UST is located, for space-heating or water-heating purposes. It does not include using heating oil to heat from a boiler or furnace through direct conductivity any product or substance used in a manufacturing or production process or using heating oil as an ingredient in a manufacturing or production process. Heating oil used to heat grain dryers or kilns is used for consumptive use on the premises (41 IAC 170.400).

• Liquid-mounted Seal - a primary seal mounted in continuous contact with the liquid between the tank wall and

the floating roof edge around the circumference of the roof (35 IAC 211). • Metallic Shoe-type Seal - a primary or secondary seal constructed of metal sheets (shoes) which are joined

together to form a ring, springs, or levers which attach the shoes to the floating roof and hold the shoes against the tank wall, and a coated fabric which is suspended from the shoes to the floating roof (35 IAC 211).

• Metro East Area - the area comprised of Madison, Monroe, and St. Clair Counties (35 IAC 219.100) [Added

May 1999]. • New Tank System - a tank system that will be used to contain an accumulation of regulated substances and for

which installation has commenced after 22 April 1989. A new tank system may include a tank which has been installed, contained regulated substances, removed and re-certified by the manufacturer (41 IAC 170.400).

• Petroleum - the crude oil removed from the earth and the oils derived from tar sands, shale, and coal (35 IAC

211). • Petroleum - includes, but is not limited to, petroleum-based substances comprised of a complex blend of

hydrocarbons derived from crude oil through processes of separation, conversion, upgrading, or finishing, such as motor fuels, jet fuels, distillate fuel oils, residual fuel oils, lubricants and petroleum solvents (41 IAC 170.400).

• Petroleum Liquid - crude oil, condensate, or any finished or immediate product manufactured at a petroleum

refinery, but not including Number 2 through Number 6 fuel oils as specified in ASTM D-396-69, gas turbine fuel oils Numbers 2-GT through 4-GT as specified in ASTM D-2880-71 or diesel fuel oils Numbers 2-D and 4-D, as specified in ASTM D-975-68 (35 IAC 211).

• Pressure Tank - a tank in which fluids are stored at a pressure greater than atmospheric pressure (35 IAC 211).

Page 266: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-3 Storage Tank Management

• Processing - chemical or physical operations designed to produce from, used oil, or to make used oil more amenable for production of, fuel oils, lubricants, or other used oil-derived product. Processing includes (41 IAC 170.400):

1. blending used oil with virgin petroleum products 2. blending used oils to meet the fuel specification 3. filtration 4. simple distillation 5. chemical or physical separation 6. re-refining.

• Regulated Substance - any petroleum product or hazardous substance listed in 40 Code of Federal Regulations (CFR) 302.4 (41 IAC 170.400).

• Reid Vapor Pressure - the standardized measure of the vapor pressure of a liquid in pounds per in.2 absolute

(kPa) at 100 °F (37.8 °C) (35 IAC 215). • Safety Relief Valve - a valve which is normally closed and which is designed to open in order to relieve

excessive pressures within a vessel or pipe (35 IAC 211). • Service Station - any place of business where gasoline, fuel oil, or any other volatile fuels for motor vehicles or

internal combustion engines are sold or offered for retail sale, or dispensed into the engines of such motor vehicles, or into approved containers, except hobby shops and small engine repair facilities (41 IAC 170.400).

• Stationary Storage Tank - any container of liquid or gas which is designed and constructed to remain at one site

(35 IAC 211). • Submerged Loading Pipe - any loading pipe the discharge opening of which is entirely submerged when the

liquid level is 6 in. above the bottom of the tank. When applied to a tank which is loaded from the side, any loading pipe the discharge of which is entirely submerged when the liquid level is 18 in. or two times the loading pipe diameter, whichever is greater, above the bottom of the tank. The definition shall also apply to any loading pipe which is continuously submerged during loading operations (35 IAC 211).

• True Vapor Pressure - the equilibrium partial pressure exerted by a petroleum liquid as determined in

accordance with methods described in the American Petroleum Institute Bulletin 2517, “Evaporation Loss From Floating Roof Tanks” (1962) (35 IAC 211).

• Underground Storage Tank (UST) - any one or a combination of tanks (including underground pipes and

cathodic protection connected thereto) that is used to contain an accumulation of regulated substances, and the volume of which (including the volume of underground pipes connected to the tank) is 10 percent or more beneath the surface of the ground. A tank containing less than 4 percent petroleum of the total volume of its contents and no hazardous substance is not a UST. A tank system classified as a UST may not be re-classified as being a non-UST unless it has been recertified by the manufacturer. A UST system does include an emergency power generator tank that stores any classification of fuel for use exclusively, alternately or concurrently by an emergency power generator. This term does not include any of the following (41 IAC 170.400):

1. a farm or residential tank of 1100 gal or less capacity used for storing motor fuel for noncommercial purposes

2. a tank used for storing heating oil for consumptive use on the premises where stored 3. a septic tank 4. a pipeline facility (including gathering lines) regulated under:

a. the Natural Gas Pipeline Safety Act of 1968 b. the Hazardous Liquid Pipeline Safety Act of 1979 c. the Illinois Gas pipeline Safety Act

5. surface impoundment, pit, pond, or lagoon

Page 267: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-4 Storage Tank Management

6. stormwater or wastewater collection system 7. flow-through process tank 8. liquid trap or associated gathering lines directly related to oil or gas production and gathering operations 9. storage tank situated in an underground area (such as a basement, cellar, mineworking, drift, shaft, or tunnel) if the storage tank is situated upon or above the surface of the floor 10. tank abandoned by filling with inert material in compliance with regulations issued by the Office of the State Fire Marshall 11. tanks with a capacity of less than 110 gal 12. hydraulic lift tanks.

• Vapor Balance System - any combination of pipes or hoses which creates a closed system between the vapor spaces of an unloading tank and a receiving tank such that vapors displaced from the receiving tank are transferred to the tank being unloaded (35 IAC 211).

• Vapor Collection System - all piping, seals, hoses, connections, pressure-vacuum vents, and other possible

sources between the gasoline delivery vessel and the vapor processing unit and/or the storage tanks and vapor holder (35 IAC 211).

• Vapor Control System - any system that prevents release to the atmosphere of organic material in the vapors

displaced from a tank during the transfer of gasoline (35 IAC 211). • Vapor-Mounted Primary Seal - a primary seal mounted with an air space bounded by the bottom of the primary

seal, the tank wall, the liquid surface, and the floating roof (35 IAC 211). • Vapor Recovery System - a vapor gathering system capable of collecting all VOM vapors and gases discharged

from the storage tank and a vapor disposal system capable of processing such VOM vapors and gases so as to prevent their emission to the atmosphere (35 IAC 211).

• Volatile Organic Liquid (VOL) - any substance which is liquid at storage conditions and which contains volatile

organic compounds (35 IAC 211). • Volatile Organic Material (VOM) or Volatile Organic Compound (VOC) - any compound of carbon, excluding

carbon monoxide, carbon monoxide, carbon dioxide, carbonic acid, metallic carbides or carbonates, and ammonium carbonate, which participates in atmospheric photochemical reactions. This includes any such organic compound other than the following, which have been determined to have negligible photochemical reactivity (35 IAC 211) [Added May 1998; Revised May 1999]:

1. methane 2. ethane 3. methylene chloride (dichloromethane) 4. 1,1,1-trichloroethane (methyl chloroform) 5. 1,1,2-trichloro-1,2,2-trifluoroethane (CFC-113) 6. trichlorofluoromethane (CFC-11) 7. dichlorodifluoromethane (CFC-12) 8. chlorodifluoromethane (CFC-22) 9. trifluoromethane (HFC-23) 10. difluoromethane (HFC-32) 11. ethylfluoride (HFC-161) 12. 1,2-dichloro-1,1,2,2-tetrafluoroethane (CFC-114) 13. chloropentafluoroethane (CFC-115) 14. 1,1,1-trifluoro-2,2-dichloroethane (HCFC-123) 15. 1,1,1,2-tetrafluoroethane (HFC-134a) 16. 1,1,1,2,3,3-hexafluoropropane (HFC-236ea) 17. 1,1,1,3,3,3-hexafluoropropane (HFC-236fa)

Page 268: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-5 Storage Tank Management

18. 1,1,2,2,3-pentafluoropropane (HFC-245ca) 19. 1,1,2,3,3-pentafluoropropane (HFC-245ea) 20. 1,1,1,2,3-pentafluoropropane (HFC-245eb) 21. 1,1,1,3,3-pentafluoropropane (HFC-245fa) 22. 1,1,1,3,3-pentafluorobutane (HFC-365mfc) 23. chlorofluoromethane (HCFC-31) 24. 1,2-dichloro-1,1,2-trifluoroethane (HCFC-123a) 25. 1,1-dichloro-1-fluoroethane (HCFC-141b) 26. 1,1-dichloro-1-fluoroethane (HCFC-141b) 27. 1-chloro-1,1-difluoroethane (HCFC-142b) 28. 2-chloro-1,1,1,2-tetrafluoroethane (HCFC-124) 29. pentafluoroethane (HFC-125) 30. 1-chloro-1-fluoroethane (HCFC-151a) 31. 3,3-dichloro-1,1,1,2,2-pentafluoropropane (HCFC-225ca) 32. 1,3-dichloro-1,1,2,2,3-pentafluoropropane (HCFC-225cb) 33. 1,1,1,2,3,4,4,5,5,5-decafluoropentane (HFC-43-10mee) 34. 1,1,2,2-tetrafluoroethane (HFC-134) 35. 1,1,1-trifluoroethane (HFC-143a) 36. 1,1-difluoroethane (HFC-152a) 37. perfluorocarbon parachlorobenzotrifluoride (PCBTF) 38. 1,1,1,2,2,3,3,4,4-nonafluoro-4-methoxybutane (C(4)F(9)OCH(3)) 39. 1-ethoxy-1,1,2,2,3,3,4,4,4-nonafluorobutane (C(4)F(9)OC(2)H(5)) 40. 2-(difluoromethoxymethyl)-1,1,1,2,3,3,3-heptafluoropropane ((CF(3))(2)CFCF(2)OCH(3)) 41. 2-(ethoxydifluoromethyl)-1,1,1,2,3,3,3-heptafluoropropane ((CF(3))(2)CFCF(2)OC(2)H(5)) 42. perchloroethylene (tetrachloroethylene) 43. cyclic, branched, or linear completely-methylated siloxanes 44. acetone (2-propanone or dimethylketone) 45. methyl acetate 46. perfluorocarbon compounds which fall into these classes:

a. cyclic, branched, or linear, completely fluorinated alkanes b. cyclic, branched, or linear, completely fluorinated ethers with no unsaturations c. cyclic, branched, or linear, completely fluorinated tertiary amines with no unsaturations and d. sulfur containing perfluorocarbons with no unsaturations and with sulfur bonds only to carbon and

fluorine. • Volatile Petroleum Liquid - any petroleum liquid with a true vapor pressure greater than 1.5 psia (78 mm Hg) at

standard conditions (35 IAC 211).

Page 269: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-6 Storage Tank Management

Page 270: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-7 Storage Tank Management

STORAGE TANK MANAGEMENT

GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: Missing Checklist Items ST.2.1.IL. Aboveground Storage Tanks ST.5.1.IL. Emissions/Discharges From Bulk Gasoline Terminals ST.10.1.IL. through ST.10.3.IL. Emissions/Discharges From POL Storage Vessels ST.15.1.IL. through ST.15.5.IL.

Gasoline Dispensing Facilities in the Chicago Area ST.15.6.IL. and ST.15.7.IL. Emissions/Discharges From VOL Storage Vessels ST.20.1.IL. and ST.20.2.IL. UST State-Specific ST.30.1.IL. through ST.30.8.IL. New or Upgraded USTs ST.35.1.IL. through ST.35.4.IL. Changes in Service or Closure of USTs ST.95.1.IL. through ST.95.4.IL.

GUIDANCE FOR APPENDIX USERS

REFER TO APPENDIX NUMBERS: REFER TO APPENDIX TITLES:

10-1

Maximum Deflection Standards for Nonmetallic USTS

Page 271: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-8 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.2. MISSING CHECKLIST ITEMS

ST.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 272: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-9 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.5. ABOVEGROUND STORAGE TANKS

ST.5.1.IL. The storage of Class I, II, or III liquids (except kerosene) in above ground storage tanks (ASTs) must meet specific requirements (41 IAC 180.20(a) and (b)) [Citation Revised May 1998].

Verify that ASTs used for dispensing Class I, II, or III liquids meet the following requirements:

- an inspection of the premises and operations has been made and approval granted by the Office of the State Fire Marshal (approval will be granted if curb pumps are not present and if pumps are not located in any portion of a public highway)

- dispensing is done on premises not open to the public - tanks are safeguarded against collision, spillage, or overfill to the satisfaction

of the authorities - each tank system is listed or approved for aboveground use by the Office of

the State Fire Marshal - any top-fill opening with a closure is designed so that it may be locked - the tank has a vent to relieve vacuum or pressure developed during normal

operation that has a minimum unobstructed opening of 1-1/2 in. in diameter and is elevated to a height of at least 4 ft (or as directed)

- tanks are equipped with a permanently connected pumping device listed under the Underwriter’s Laboratories (UL)

- pumps are equipped with a padlock to prevent tampering - antisiphoning devices are included in the pump discharge (siphons or internal

pressure discharge devices are prohibited) - gravity method of discharge is not used.

Verify that tanks used for the storage of flammable or combustible liquids are marked with the name of the product they contain and FLAMMABLE -- KEEP FIRE AND FLAME AWAY, both in 4 in. high letters and in colors contrasting from the tank.

Verify that a maximum of only two ASTs of up to 2500 gal each is used for storage of flammable or combustible liquids at each facility, and that the tanks are constructed of steel and made vapor tight.

Verify that tanks outside are 30 ft from any building or combustible or flammable stored liquid or liquid petroleum to ensure that no vehicle, equipment, or vessel being filled directly from any such tank is closer than 30 ft to any building, combustible or flammable stored liquid, liquid petroleum gas tank, or property line.

(NOTE: Tanks protected within a 2-h fire resistant enclosure may be located adjacent to a structure after a request in writing to construct an enclosure has been approved.)

Page 273: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-10 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Page 274: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-11 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.10. EMISSIONS/ DISCHARGES FROM BULK GASOLINE TERMINALS

ST.10.1.IL. Bulk gasoline plants must meet specific operational requirements (35 IAC 215.581(c) and (d), 218.581(e) and 219.581(e)) [Revised May 1999].

(NOTE: In the Chicago and Metro East Areas (see definitions), these requirements do not apply to any stationary storage tank with a capacity of less than 575 gal, or to any bulk gasoline plant whose daily gasoline throughput is less than 4000 gal on a rolling 30-day average. Elsewhere in the state, this does not apply to any stationary storage tank with a capacity of less than 575 gal, or to any bulk gasoline plant whose annual gasoline throughput is less than 350,000 gal as averaged over the preceding 3 calendar years.)

Verify that any bulk gasoline plant maintains and operates the vapor control sys-tem(s).

Verify that any bulk gasoline plant maintains gauges, meters, or other specified testing devices in good working order.

Verify that any bulk gasoline plant operates the bulk plant vapor collection system and gasoline loading equipment in a manner that prevents:

- the gauge pressure from exceeding 18 in. of water and vacuum from exceeding 6 in. of water, as measured as close as possible to the vapor hose connection

- a reading equal to or greater than 100 percent of the lower explosive limit (LEL measured as propane) when tested in accordance with the procedure described in USEPA 450/2-78-051 Appendix B

- avoidable leaks of liquid during loading or unloading operations.

Verify that any bulk gasoline plant provides a pressure tap or equivalent on the bulk plant vapor collection system

Verify that any bulk gasoline plant repairs and retests a vapor collection system within 15 business days after discovery of a leak.

Verify that the owner of a stationary storage tank located at a bulk gasoline plant:

- provides instructions to the operator of the bulk gasoline plant describing necessary maintenance operations and procedures for prompt notification of the owner in case of any malfunction of a vapor control system

- repairs, replaces or modifies any worn out or malfunctioning component or element of design.

Page 275: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-12 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.10.2.IL. Gasoline transfer operations at bulk gasoline plants must meet specific vapor control requirements (35 IAC 215.581(a), (b), (d)(4), (e), (f), and 215.584(b) and (d); 218.581(e) and (f), and 219.581(e) and (f)) [Revised May 1999].

(NOTE: In the Chicago and Metro East Areas, these requirements do not apply to any stationary storage tank with a capacity of less than 575 gal, or to any bulk gasoline plant whose daily gasoline throughput is less than 4000 gal on a rolling 30-day average. Elsewhere in the state, this does not apply to any stationary storage tank with a capacity of less than 575 gal, or to any bulk gasoline plant whose annual gasoline throughput is less than 350,000 gal as averaged over the preceding 3 calendar years.)

Verify that the transfer of gasoline is not allowed between a delivery vessel and a stationary storage tank unless both are equipped with a vapor collection system that prevents:

- the gauge pressure from exceeding 18 in. of water and vacuum from exceeding 6 in. of water, as measured as close as possible to the vapor hose connection

- a reading equal to or greater than 100 percent of the lower explosive limit (LEL measured as propane) when tested in accordance with the procedure described in USEPA 450/2-78-051 Appendix B

- avoidable leaks of liquid during loading or unloading operations.

Verify that there is no transfer of gasoline between a delivery vessel and a station-ary storage tank unless:

- each vapor collection system is operating - the delivery vessel displays a sticker affixed to the tank adjacent to the tank

manufacturer’s data plate which contains the tank identification number, the date of leak testing, and the tester’s name

- the pressure relief valve(s) on the stationary storage tank and the delivery vessel are set to release at no less than 0.7 psi or the highest pressure allowed by state or local fire codes or the guidelines of the National Fire Prevention Association.

Verify that there is no transfer from a delivery vessel into a stationary storage tank unless the tank is equipped with a submerged loading pipe.

Verify that there is no transfer from a stationary storage tank into a delivery vessel unless equipment is available to provide for submerged filling, or the delivery vessel is equipped for bottom loading.

ST.10.3.IL. Gasoline transfer operations at bulk gasoline terminals must meet specific vapor control requirements (35 IAC 215.582).

(NOTE: The requirements for the Chicago and Metro East Areas are identical to those for the rest of the state.)

Verify that the transfer of gasoline is not allowed into any delivery vessel from any bulk gasoline terminal unless:

- the bulk gasoline terminal is equipped with a vapor control system that limits emission of volatile organic material to 80 mg/l (0.00067 lbs/gal) of gasoline

Page 276: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-13 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

loaded - the vapor control system is operating and all vapors displaced in the loading

of gasoline to the delivery vessel are vented only to the vapor control system - there is no liquid drainage from the loading device when it is not in use - all loading and vapor return lines are equipped with fittings which are vapor

tight - the delivery vessel displays a sticker affixed to the tank adjacent to the tank

manufacturer’s data plate which contains the tank identification number, the date of leak testing, and the tester’s name, or, if the terminal is driver-loaded, terminal access authorization is limited to those owners and/or operators of delivery vessels who have provided a current certification.

Verify that the terminal vapor collection system and gasoline loading equipment is

operated in a manner that prevents:

- gauge pressure from exceeding 18 in. of water and vacuum from exceeding 6 in. of water as measured as close as possible to the vapor hose connection, and

- a reading equal to or greater than 100 percent of the lower explosive limit (LEL measured as propane) when tested in accordance with the procedure described in EPA 450/2-78-051 Appendix B

- avoidable leaks of liquid during loading or unloading operations.

Verify that a pressure tap or equivalent is provided on the terminal vapor collection system in order to allow the determination of compliance.

Verify that the operator of a bulk gasoline terminal, within 15 business days after discovery of the a leak by the owner, operator, or the Agency, repairs and retests a vapor collection system which exceeds the limits.

Page 277: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-14 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.15. EMISSIONS/ DISCHARGES FROM POL STORAGE VESSELS

ST.15.1.IL. Petroleum storage vessels must meet specific requirements for vapor control (35 IAC 215.123, 218.123 and 219.123) [Revised May 1999].

(NOTE: The requirements for the Chicago and Metro East Areas are identical to those for the rest of the state.)

(NOTE: These requirements do not apply to any stationary storage tank: - equipped before 1 January 1979 with one of the vapor loss control devices

specified in Section 215.121(b), except Section 215.121(b)(1) (see ST.20.1.IL.)

- with a capacity of less than 151.42 m3 with a capacity of less than 1600 m3 (422,400 gal) and used to store

produced crude oil and condensate prior to custody transfer - with a capacity of less than 1430 m3 (378,000 gal) and used to store

produced oil or condensate in crude oil gathering - subject to new source performance standards for storage vessels of petroleum

liquid, 40 CFR 60 - in which volatile petroleum liquid is not stored; or - which is a pressure tank as described in Section 215.121(a).)

Verify that any volatile petroleum liquid is not stored in the tank unless:

- the tank is equipped with one of the vapor loss control devices specified in Section 215.121(b) of this Part

- there are no visible holes, tears or other defects in the seal or any seal fabric or material of any floating roof

- all openings of any floating roof deck, except stub drains, are equipped with covers, lids, or seals such that:

- the cover, lid, or seal is in the closed position at all times except when petroleum liquid is transferred to or from the tank

- automatic bleeder vents are closed at all times except when the roof is floated off or landed on the roof leg supports

- rim vents, if provided, are set to open when the roof is being floated off the roof leg supports or at the manufacturer's recommended setting

- routine inspections of floating roof seals are conducted through roof hatches once every 6 mo

- a complete inspection of the cover and seal of any floating roof tank is made whenever the tank is emptied for reasons other than the transfer of petroleum liquid during the normal operation of the tank, or whenever repairs are made as a result of any semi-annual inspection or incidence of roof damage or defect

- a record of the results of each inspection is maintained.

Page 278: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-15 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.15.2.IL. Stationary storage tanks with external floating roofs must meet requirements for secondary seals (35 IAC 215.124, 218.124 and 219.124) [Revised May 1999].

Verify that volatile petroleum liquids are not stored in stationary storage tank equipped with an external floating roof causes unless:

- the tank has been fitted with a continuous secondary seal extending from the floating roof to the tank wall (rim mounted secondary seal) or any other device which controls volatile organic material emissions with an effectiveness equal to or greater than a rim-mounted secondary seal

- each seal closure device meets the following requirements: - the seal is intact and uniformly in place around the circumference of the

floating roof between the floating roof and tank wall, and - the accumulated area of gaps exceeding 0.32 cm (1/8 in.) in width

between the secondary seal and the tank wall does not exceed 21.2 cm2/meter of tank diameter (1.0 in.2/foot of tank diameter)

- emergency roof drains are provided with slotted membrane fabric covers or equivalent covers across at least 90 percent of the area of the opening

- openings are equipped with projections into the tank which remain below the liquid surface at all times

- inspections are conducted prior to 1 May of each year to insure compliance - the secondary seal gap is measured prior to 1 May of each year - records of the types of volatile petroleum liquid stored, the maximum true

vapor pressure of the liquid as stored, the results of the inspections and the results of the secondary seal gap measurements are maintained and available to the Agency, upon verbal or written request, at any reasonable time for a minimum of two years after the date on which the record was made.

(NOTE: These requirements do not apply to any stationary storage tank equipped

with an external floating roof: - with a capacity of less than 151.42 m3

- with a capacity of less than 1430 m3 (378,000 gal) and used to store produced oil or condensate in crude oil gathering

- subject to new source performance standards for storage vessels of petroleum liquid, 40 CFR 60

- in which volatile petroleum liquid is not stored - of welded construction equipped with a metallic-type shoe seal having a

secondary seal from the top of the shoe seal to the tank wall - of welded construction equipped with a metallic-type shoe seal, a liquid-

mounted foam seal, a liquid-mounted liquid-filled-type seal, or other closure device of equivalent control efficiency approved by the Agency in which a petroleum liquid with a true vapor pressure less than 27.6 kPa (4.0 psia) at 294.3 °K (70 °F) is stored (for the Chicago and Metro East Areas, this subparagraph is changed in part to read "a metallic type shoe seal, a liquid-mounted liquid-filled-type seal, or other closure device of equivalent control efficiency")

- used to store crude oil (for the Chicago and Metro East Areas, used to store crude oil with a pour point of 50 °F or higher).)

Page 279: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-16 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.15.3.IL. Facilities that receive Class I or II liquids from tank cars must meet spe-cific loading and unloading requirements (41 IAC 160.320 through 160.370).

Verify that before any loading or unloading operation begins, the tank car is electrically grounded, and permanent electrical connection of not less than No. 0 copper cable is made between the rails and the piping system of the storage plant.

Verify that liquids are not withdrawn by gravity or from tank cars through bottom outlets; tank cars may be unloaded through dome (manhole) only, and pumps must conform to National Electrical Code NFPA 70.

(NOTE: Fuel oils for heating may be unloaded by gravity.)

Verify that compressed air is not used to discharge the contents of tank cars.

Verify that the contents of tank cars are not unloaded into portable containers.

Verify that, after the unloading pipe is inserted into the dome of the tank car, the dome is tightly covered to limit the release of flammable vapors.

Verify that all connections between the tank car and pipe lines are in good condition and are not leaking.

Verify that tank cars are not left connected to pipe lines except when loading or unloading.

Verify that a person is present at all times during loading or unloading operations

Verify that the presence of flame lanterns, flame switch lights, or other exposed flame lights or fires is prohibited.

ST.15.4.IL. Gasoline dis-pensing operations must meet specific standards (35 IAC 215.583(a) through (d), and 218.583(a) and 219.583(a)) [Revised May 1999].

Verify that the transfer of gasoline from any delivery vessel into any stationary storage tank at a gasoline dispensing operation is allowed only if:

- the tank is equipped with a submerged loading pipe - the vapors displaced from the storage tank during filling are processed by a

vapor control system that includes one or more of the following: - a vapor collection system that prevents a reading equal to or greater

than 100 percent of the lower explosive limit (LEL measured as propane) when tested according to EPA 450/ 2-78-051 Appendix B and avoidable leaks of liquid during the filling of storage tanks

- a refrigeration-condensation system or any other system approved by the Agency, that recovers at least 90 percent by weight of all vaporized organic material from the equipment being controlled

- the delivery vessel displays the appropriate sticker.

Verify that, in the Chicago and Metro East Areas:

Page 280: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-17 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- all tank vent pipes are equipped with pressure/vacuum relief valves that resist a pressure of at least 3.5 in. water column and a vacuum of no less than 6.0 in. water column

- the facility demonstrates compliance with the above requirement, by 15 March 1995 or 30 days after installation of each pressure/vacuum relief valve, whichever is later, and at least annually thereafter, by measuring and recording the pressure indicated by a pressure/vacuum gauge at each tank vent pipe.

(NOTE: The test must be performed on each tank vent pipe within 2 h after

product delivery into the respective storage tank. For manifold tank vent systems, observations at any point within the system will be adequate.)

Verify that records are maintained for a period of 3 yr.

(NOTE: The transfer of gasoline to a stationary storage tank at a gasoline disposing operation is not required to meet the vapor collection requirements above (only the requirement for a submerged loading pipe) if:

- the tank is equipped with a floating roof or other system of equal or better emission control approved by the Agency or the USEPA

- the tank has a capacity of less than 2000 gal and was in place and operating before 1 January 1997

- the tank has a capacity of less than 575 gal.)

Verify that gasoline operations (not exempt according to the above NOTE) meet the following requirements:

- install all control systems and make all process modifications required above - provide instructions to the operator of the gasoline dispensing operation

describing necessary maintenance operations and procedures for prompt notification of the facility in case of any malfunction of a vapor control system

- repair, replace, or modify any worn out or malfunctioning component or element of design

- maintain and operate each vapor control system in accordance with facility instructions

- promptly notify the facility of any scheduled maintenance or malfunction requiring replacement or repair of a major component of a vapor control system

- maintain gauges, meters, or other specified testing devices in proper working order

- operate the vapor control system and delivery vessel unloading points in a manner that prevents:

- a reading equal to or greater than 100 percent of the lower explosive limit (LEL measured as propane) when tested according to EPA 450/2-78-051 Appendix B

- avoidable leaks of liquid during the filling of storage tanks - within 15 business days after discovery of the leak by the facility, repair, and

retest the vapor collection system which exceeds the above limits.

Page 281: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-18 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.15.5.IL. Flammable or combustible liquid dispensing operations must meet certain requirements (41 IAC 180.20(c)).

Verify that dispensing operations have the following:

- a top-fill opening with a closure designed so that it may be locked - a vent to relieve vacuum or pressure developed during normal operation as

follows: - minimum unobstructed opening of 1-1/2 in. in diameter and be elevated

to a height of at least 4 ft (or as directed) - tanks equipped with a permanently connected pumping device listed

under the Underwriter’s Laboratories (UL) - pumps equipped with a padlock to prevent tampering - antisiphoning devices included in the pump discharge (siphons or

internal pressure discharge devices are prohibited).

(NOTE: The gravity method of discharge is prohibited.)

Verify that tanks used for the storage of flammable or combustible liquids are marked with the name of the product they contain and FLAMMABLE -- KEEP FIRE AND FLAME AWAY, both in 4 in. high letters and in colors contrasting from the tank.

Verify that a maximum of only two ASTs of up to 2500 gal each, constructed throughout of steel and vapor tight, are used to store flammable or combustible liquids outside building.

Gasoline Dispensing Facilities in the Chicago Area

(NOTE: These provisions apply to any gasoline dispensing operation which dispenses an average monthly volume of more than 10,000 gallons of motor vehicle fuel per month. Any gasoline dispensing operation that becomes subject to these provisions at any time will remain subject to these provisions at all times.)

ST.15.6.IL. Gasoline dispensing facilities must meet vapor collection and control system requirements (35 IAC 218.586(c)) [Added May 1999].

Verify that there is no dispensing of motor vehicle fuel from a motor fuel dispenser unless the dispenser is equipped with and utilizes a vapor collection and control system which is properly installed and operated as follows:

- any vapor collection and control system installed, used or maintained has been CARB certified

- any vapor collection and control system utilized is maintained in accordance with the manufacturer's specifications and the certification

- no elements or components of a vapor collection and control system are modified, removed, replaced or otherwise rendered inoperative in a manner which prevents the system from performing in accordance with its certification and design specifications

- a vapor collection and control system has no defective, malfunctioning or

Page 282: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-19 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

missing components - operators and employees of the gasoline dispensing operation are trained and

instructed in the proper operation and maintenance of a vapor collection and control system

- instructions are posted in a conspicuous and visible place within the motor fuel dispensing area and describe the proper method of dispensing motor vehicle fuel with the use of the vapor collection and control system.

ST.15.7.IL. Gasoline dispensing facilities must meet recordkeeping and reporting requirements (35 IAC 218.586(g)) [Added May 1999].

Verify that gasoline dispensing operations retain at the operation copies of the registration information.

Verify that records and reports are made available to the Agency upon request, and clearly demonstrate:

- that a certified vapor collection and control system has been installed and tested to verify its performance according to its specifications

- that proper maintenance has been conducted in accordance with the manufacturer's specifications and requirements

- the time period and duration of all malfunctions of the vapor collection and control system

- the motor vehicle fuel throughput of the operation for each calendar month of the previous year.

- that operators and employees are trained and instructed in the proper operation and maintenance of the vapor collection and control system and informed as to the potential penalties associated with the violation of any provision of this Section.

Page 283: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-20 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.20. EMISSIONS/ DISCHARGES FROM VOL STORAGE VESSELS

ST.20.1.IL. Tanks storing volatile organic liquids (VOLs) in any stationary tank, reservoir or other container of more than 151 m3 (40,000 gal) capacity must meet spe-cific design and construction requirements (35 IAC 215.121, 218.121, and 219.121) [Revised May 1999].

(NOTE: In the Chicago and Metro East Areas (see definitions), this checklist item applies to the storage of volatile petroleum liquids (VPL) with a vapor pressure of 10.34 kPa (1.5 psia) or greater at 294.3 °K (70 °F).)

Verify that the storage of any volatile organic liquid with a vapor pressure of 17.24 kPa (2.5 psia) or greater at 294.3 °K (70 °F) or any gaseous organic material in any stationary tank, reservoir or other container of more than 151 m3 (40,000 gal) capacity is allowed unless the tank, reservoir, or other container meets one of the following requirements:

- is a pressure tank capable of withstanding the vapor pressure of such liquid or the pressure of the gas, so as to prevent vapor or gas loss to the atmosphere at all times; or

- is designed and equipped with a vapor loss control device.

Verify that, if a vapor loss control device is used, it is equipped with the following:

- a floating roof which rests on the surface of the volatile organic liquid and is equipped with a closure seal or seals between the roof edge and the tank wall (such floating roof will not be permitted if the VOL or VPL has a vapor pressure of 86.19 kPa (12.5 psia) or greater at 294.3 °K (70 °F); no person may cause or allow the emission of air contaminants into the atmosphere from any gauging or sampling devices attached to such tanks, except during sampling or maintenance operations)

- a vapor recovery system consisting of: - a vapor gathering system capable of collecting 85 percent or more of

the uncontrolled volatile organic material that would be otherwise emit-ted to the atmosphere

- a vapor disposal system capable of processing such volatile organic material so as to prevent its emission to the atmosphere (no person may cause or allow the emission of air contaminants into the atmosphere from any gauging or sampling devices attached to such tank, reservoir or other container except during sampling)

- other equipment or means of equal efficiency approved by the Agency.

ST.20.2.IL. Loading operations must meet VOL control requirements (35 IAC 215.122, 218.122 and

(NOTE: The requirements for the Chicago and Metro East Areas are identical to those for the rest of the state.)

Verify that the discharge is not allowed of more than 3.6 kg/hr (8 lb/hr) of organic

Page 284: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-21 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

219.122) [Revised May 1999].

material into the atmosphere during the loading of any organic material from the aggregate loading pipes of any loading facility having through-put of greater than 151 m3/day (40,000 gal/day) into any railroad tank car, tank truck or trailer unless the loading facility is equipped with submerged loading pipes, submerged fill or a device that is equally effective in controlling emissions and is approved by the Agency.

Verify that the loading of any organic material into any stationary tank having a storage capacity of greater than 946 L (250 gal) is not allowed, unless the tank is equipped with a permanent submerged loading pipe, submerged fill or an equivalent device approved by the Agency, or unless the tank is a pressure tank or is fitted with a recovery system.

(NOTE: If no odor nuisance exists these limitations, apply only to the loading of volatile organic liquid with a vapor pressure of 17.24 kPa (2.5 psia) or greater at 70°F.)

VOL Storage and Operations in the Chicago and Metro East Areas

(NOTE: The requirements in this subsection apply only in the Chicago and Metro East Areas (see definitions).

ST.20.3.IL. Storage containers of VOLs must meet specific emission control requirements (35 IAC 218.119, 218.120, 218.127, and 219.119, 219.120, and 219.127) [Added May 1999].

(NOTE: These limitations apply to all storage containers of VOL with a maximum true vapor pressure of 0.5 psia or greater in any stationary tank, reservoir, or other container of 151 cubic meters (40,000 gal) capacity or greater, except to vessels as provided below:

- vessels with a capacity greater than or equal to 40,000 gallons storing a liquid with a maximum true pressure of less than 0.5 psia

- vessels of coke oven by-product plants - pressure vessels designed to operate in excess of 29.4 psia and without

emissions to the atmosphere - vessels permanently attached to mobile vehicles such as trucks, rail cars,

barges or ships - vessels storing petroleum liquids - vessels used to store beverage alcohol.)

(NOTE: Vessels with storage capacity less than 40,000 gallons must comply with

Section 218.129(f) (see ST.20.6.IL.)

Verify that vessels of 40,000 gallons or greater used to store VOL with a maximum true vapor pressure equal to 0.75 psia but less than 11.1 psia reduce VOM emissions from storage tanks, reservoirs, or other containers using one of the following methods:

- a fixed roof tank equipped with an internal floating roof (or equipped with a vapor control system)

- an external floating roof tank

Page 285: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-22 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- a closed vent system and control device - an alternative emission control plan that has been approved by the Agency

and the USEPA in a federally enforceable permit or as a SIP revision.

Verify that the owner or operator of each storage vessel with a design capacity equal to or greater than 40,000 gal which contains VOL that, as stored, has a maximum true vapor pressure greater than or equal to 11.1 psia equips each storage vessel with a closed vent system and control device.

(NOTE: Where an owner or operator can demonstrate that the control device installed on a storage vessel on or before 31 December 1992, was designed to reduce inlet VOM emissions by greater than or equal to 90 percent but less than 95 percent, the control device will be operated to reduce inlet VOM emission by 90 percent or greater.)

ST.20.4.IL. Storage containers of VOLs must meet specific testing and inspection requirements (35 IAC 218.119, 218.127, and 219.119 and 219.127) [Added May 1999].

(NOTE: This checklist item only applies to vessels subject to the requirements of ST.20.3.IL.)

Verify that after installing the control equipment necessary for the source to comply with these requirements by use of a permanently affixed roof and internal floating roof, each owner or operator:

- visually inspects the internal floating roof, the primary seal, and the secondary seal (if one is in service) prior to filling the storage vessel with VOL

- for vessels equipped with a liquid-mounted or mechanical shoe primary seal, visually inspects the internal floating roof and the primary seal or the secondary seal (if one is in service) manholes and roof hatches on the fixed roof at least once every 12 mo after initial fill

- for vessels equipped with both primary and secondary seals, visually inspects the vessel at least every 5 yr

- visually inspects the internal floating roof, the primary seal the secondary seal (if one is in service), gaskets, slotted membranes, and sleeve seals (if any) each time the storage vessel is emptied and degassed

- notifies the Agency in writing at least 30 days prior to the filling, or refilling of each storage vessel for which an inspection is required.

Verify that the owner or operator of external floating roof tanks:

- determines the gap areas and maximum gap widths between the primary seal and the wall of the storage vessel and between the secondary seal and the wall of the storage vessel

- performs measurements of gaps between the tank wall the primary seal (seal gaps) during the hydrostatic testing of the vessel or within 60 days after the initial fill with VOL and at least once every 5 yr thereafter

- performs measurements of gaps between the tank wall and the secondary seal within 60 days after the initial fill with VOL and at least

Page 286: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-23 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

once per year thereafter - determines gap widths and areas in the primary and secondary seals

individually - adds the gap surface area of each gap location for the primary seal and the

secondary seal individually and divides the sum for each by the nominal diameter of the tank and compare each ratio to the respective standards listed below

- makes necessary repairs or empties the storage vessel within 45 days after identification in any inspection for seals where the accumulated area of gaps between the tank wall and the mechanical shoe or liquid-mounted primary seal exceed 10 in.2 per foot of tank diameter, and the width of any portion of any gap exceeds 1.5 in., or there are holes, tears, or other openings in the shoe, seal fabric, or seal envelope.

(NOTE: If a failure that is detected during inspections cannot be repaired within

45 days and if the vessel cannot be emptied within 45 days, the owner or operator may request a 30-day extension from the Agency in the inspection report.)

Verify that the owner/operator notifies the Agency 30 days in advance of any gap measurements to afford the Agency the opportunity to have an observer present.

Verify that the owner/operator inspects the external floating roof, the primary seal, secondary seal, and fittings each time the vessel is emptied and degassed.

ST.20.5.IL. Storage containers of VOLs must meet specific monitoring requirements (35 IAC 218.128 and 219.128) [Added May 1999].

Verify that the owner or operator of each storage vessel with a design capacity greater than or equal to 40,000 gal storing a liquid with a maximum true vapor pressure that is normally less than 0.75 psia notifies the Agency within 30 days when the maximum true vapor pressure of the liquid exceeds 0.75 psia.

(NOTE: The owner or operator of a vessel equipped with a closed vent system and control device is exempt from the preceding paragraph.)

Verify that the owner or operator of each vessel storing a mixture of indeterminate or variable composition:

- determines the maximum true vapor pressure for the range of anticipated liquid compositions to be stored prior to the initial filling of the vessel.

- performs an initial physical test of the vapor pressure for vessels in which the vapor pressure of the anticipated liquid composition is 0.5 psia or greater but less than 0.75 psia

- performs a physical test at least once every 6 months thereafter.

ST.20.6.IL. VOL operations must meet specific recordkeeping and reporting

Verify that the owner or operator of each storage vessel of 40,000 gallons or greater capacity used to store VOL with a maximum true vapor pressure equal to 0.75 psia but less than 11.1 psia maintains records and furnishes reports as

Page 287: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-24 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

requirements (35 IAC 218.129 and 219.129) [Added May 1999].

required below (as appropriate for the control equipment installed).

Verify that copies of all reports and records are kept for at least 3 years.

Verify that the required records are kept for the life of the control equipment.

Verify that owners/operators of vessels with fixed roof and internal floating roofs:

- furnish the Agency with a report that describes the control equipment and certifies that the control equipment meets the specifications of this Subpart

- keeps a record of each inspection performed that identifies the storage vessel on which the inspection was performed and contains the date the vessel was inspected and the observed condition of each component of the control equipment (seals, internal floating roof, and fittings)

- report to the Agency, if any defects are detected during the annual visual inspection, within 30 days after the inspection the identity of the storage vessel, the nature of the defects, and the date the storage vessel was emptied or the nature of and date the repair was made

- after each inspection where holes or tears in the seal or seal fabric, or defects in the internal floating roof, or other control equipment defects are discovered, report to the Agency within 30 days after the inspection the identity of the storage vessel and the reason it did not meet specifications, and list each repair made.

Verify that owners/operators of vessels with external floating roofs:

- furnish the Agency with a report that describes the control equipment and certifies that the control equipment meets the specifications of this Subpart

- within 60 days after performing the seal gap measurements, furnishes the Agency with a report that contains the date of measurement, the raw data obtained in the measurement, and the calculations used to determine gap areas

- maintains records of each gap measurement performed that identify the storage vessel in which the measurement was performed and contain the date of measurement, the raw data obtained in the measurement, and the calculations used to determine gap areas

- after each seal gap measurement that detects gaps exceeding the limitations listed in ST.20.4.IL., submits a report to the Agency within 30 days after the inspection identifying the vessel and containing the date of measurement, the raw data obtained in the measurement, and the calculations used to determine gap areas, and the date the vessel was emptied or the repairs were made and the date of repair.

Verify that owners/operators of vessels with closed vent systems and control

devices (other than a flare) maintain the following records:

- a copy of the operating plan - the measured values of the parameters monitored in accordance with this

Subpart.

Page 288: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-25 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that after installing a closed vent system and flare, the owner or operator:

- provides the Agency with a report containing the measurements required by 40 CFR 60.18, within 6 mo after the initial start-up date

- maintains records of all periods of operation during which the flare pilot flame is absent

- reports semiannually all periods in which the pilot flame was absent.

Verify that all records required by this Section are maintained for at least 3 years.

Verify that the owner or operator of each storage vessel maintains readily accessible records of the dimension of the storage vessel and an analysis of the capacity of the storage vessel, for the life of the vessel.

(NOTE: Each storage vessel with a design capacity less than 40,000 gallons is subject to no provisions of this Part other than those required by maintaining readily accessible records of the dimensions of the storage vessel and analysis of the capacity of the storage vessel.)

Verify that the owner or operator of each storage vessel with a design capacity greater than or equal to 40,000 gallons storing a liquid with a maximum true vapor pressure greater than or equal to 0.5 psia but less than 0.75 psia maintains a record of the VOL storage, the period of storage, and the maximum true vapor pressure of the VOL during the respective storage period.

(NOTE: The owner or operator of a vessel equipped with a closed vent system and control device is exempt from the preceding paragraph.)

Page 289: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-26 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.30. UST STATE-SPECIFIC

ST.30.1.IL. Owners of USTs must notify the State Fire Marshall (41 IAC 170.440(a)(1) and (2) and 170.440(c)).

Verify that any owner of an underground storage tank system in operation at any time after 1 January 1974, and in the ground as of 24 September 1987 has submitted a notice of existence of such tank system to the Office of the State Fire Marshal.

Verify that any owner of an underground storage tank system brought into operation on or after 21 April 1989 submits within 30 days after bringing the tank into operation a notice of existence of the tank system to the Office of the State Fire Marshal.

(NOTE: This applies even if the UST was subject to a change-in-service within the 30-day time period.)

(NOTE: UST containing heating oil not for consumptive use on the premises where stored are exempt from these requirements.)

(NOTE: Owners required to submit notices will provide notice for each tank they own. Owners may provide notice for more than one tank using one notification form, but owners who own tanks located at more than one facility will file a separate notification form for each separate facility.)

ST.30.2.IL. Owners of UST systems storing heating oil for use on the premises must notify the State Fire Marshall (41 IAC 170.440(b) and (c)).

(NOTE: This requirement applies to USTs containing heating oil for consumptive use on the premises where stored.)

Verify that any owner of a heating oil underground storage tank system greater than 1100 gal in capacity and in the ground as of 11 July 1990, has submitted a notice of existence of the tank system to the Office of the State Fire Marshal, on the form prescribed by the Office.

Verify that any owner of a heating oil underground storage tank system greater than 110 gal and less than or equal to 1100 gal in capacity and in the ground as of 6 September 1991 has submitted a notice of existence of the tank system to the Office of the State Fire Marshal, on the form prescribed by the Office.

Verify that any owner of a heating oil underground storage tank system greater than 110 gal in capacity installed after 6 September 1991 submits within 30 days after bringing the tank into operation, a notice of existence of the tank system to the Office of the State Fire Marshal, on the form prescribed by the Office.

(NOTE: This applies even if the UST was subject to a change-in-service within

Page 290: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-27 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

the 30-day time period.)

(NOTE: Heating oil tanks used exclusively for storing heating oil for consumptive use on a farm or residence are exempt from being classified as a UST.)

(NOTE: The Office of the State Fire Marshal will use the information required to be submitted to determine registrability of USTs.)

(NOTE: Owners required to submit notices will provide notice for each tank they own. Owners may provide notice for more than one tank using one notification form, but owners who own tanks located at more than one facility must file a separate notification form for each separate facility.)

ST.30.3.IL. UST fill pipes must meet specific location standards (41 IAC 170.421).

Verify that fill pipes for USTs are carried to a location outside of any building, as remote as possible from any doorway or other opening into any building, and in no case closer than 5 ft from any such opening.

(NOTE: Remote fills are subject to approval by the Office of the State Fire Marshal, on a case by case basis. Fill pipes for used oil tanks are permissible when located inside buildings.)

Verify that fill pipes are located where there is minimum danger of breakage from trucks or other vehicles.

Verify that each fill pipe is closed by a screw cap or other tight fitting cap of a type which can be locked.

Verify that the cap is locked at all times when filling or gauging process is not going on.

Verify that each loading pipe or fill pipe riser is identified by color code or labeling to indicate the product contained in the tank.

Verify that there is adequate collision protection to protect against physical damage provided for fill pipes which protrude above-grade.

ST.30.4.IL. USTs must meet specific clearance standards (41 IAC 170.422) [Revised May 1999].

(NOTE: Tanks that were in service on 1 October 1985 may maintain existing underground tank clearances.)

Verify that USTs used for dispensing are 20 or more feet from any basement, cellar, pit, or below-grade excavation on or off the property.

Verify that USTs not used for dispensing are located not less than 5 ft from a building.

Page 291: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-28 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

(NOTE: USTs not used for dispensing may be located under a building.)

Verify that individual tanks and piping are buried so that the tops of the tanks and piping are lower than the bottom level of all sewers, manholes, catch-basins, cesspools, septic tanks, wells or cisterns within 20 ft, on or off the property; or tanks and piping maintain a full clearance of 20 ft.

(NOTE: The term, sewer, includes sewer lines to out-of-service station buildings; however, clearance is not required for service lines constructed throughout with cast iron and leaded joints.)

Verify that individual tanks are at least 20 ft from a property line unless authorities with immediate jurisdictions over public streets, alleys, or highways waive this requirement.

Verify that tanks and pumps maintain a clearance of not less than 300 ft to any mine shaft, air, or escape shaft for any mine and 85 ft to any school, institutional, public assembly, or theatre occupancy as defined in NFPA 101.

Verify that hazardous substance UST systems are double-wall

(NOTE: The distances will be measured from the nearest point of tanks and pumps to the nearest point of buildings or shafts.)

(NOTE: Where the site size makes compliance with these clearance requirements an impossibility or an imposition, as determined by the Office of the State Fire Marshal during a permit review, a double-wall tank or piping system or both with interstitial monitoring, must be used and is subject to approval by the Office. Interstitial piping monitoring requirements will be waived for European Suction Piping Systems.)

ST.30.5.IL. USTs must meet specific venting requirements (41 IAC 170.424).

Verify that each tank is provided with a separate vent pipe, connected with the top of the tank and carried up to the outer air.

(NOTE: The pipe must arranged for proper drainage to the storage tank, and its lower end must not extend through top of tank for a distance of more than one inch; it must have no traps or pockets. Float vent valve overfill devices are not considered an extension of the standard vent.)

Verify that the upper end of the pipe is provided with an updraft vent device only, with 40 gauge screening, unless alterations are required by Stage II Vapor Recovery.

Verify that the vent pipe is of sufficient cross-sectional area to permit escape of air and vapor during the filling operation, and in no case less than 1-1/4 in. in diameter.

Page 292: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-29 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

(NOTE: If a power pump is used in filling storage tank, and a tight connection is made to the fill pipe, the diameter of the vent pipe must not be smaller than the fill pipe.)

Verify that the vent pipe terminates:

- outside buildings at a point one foot above the level of the highest remote fill or any fill from which the tank may be filled

- not less than 12 ft above the adjacent ground level - not less than 4 ft, measured vertically and horizontally, from any window or

other building opening, such as a basement, cellar, pit, ventilated soffit or any air intake of any building

- in a location which will not permit pocketing of vapor or liquid.

(NOTE: The vent piping must project above adjacent roof lines.)

Verify that no vent piping is inside buildings.

(NOTE: It is recommended that Stage II Vapor Recovery vent piping be connected to an individual tank opening.)

Verify that adequate collision protection is provided to protect against physical damage.

(NOTE: Hazardous substance tanks and non-motor fuel tanks must be vented in accordance with NFPA 30, incorporated by reference in Section 170.410 or as approved by the Office of the State Fire Marshal to be no less protective of human health or the environment.)

ST.30.6.IL. USTs inside or under buildings are subject to specific requirements (41 IAC 170.545) [Revised May 1999].

Verify that the floor level under which a UST is located is above-grade to prevent the flow of liquids or vapors into buildings, and the floors are of concrete or other fire resistant construction.

Verify that after 1 April 1995, no buildings are constructed over UST systems, in operation or out of operation (for any period of time).

(NOTE: Tanks exempted from removal for the following reasons are exempt from this requirement:

- USTs that have not been in operation at any time after 1 January 1974 - heating oil USTs, for consumptive use on the premises where stored.)

Verify that no USTs or dispensers containing motor fuel are installed inside

buildings, except for dispensing units existing prior to 15 September 1978 where specific written approval of the Office of the State Fire Marshal was granted by 1 October 1985, and proof was submitted by the applicant and verified by the Office.

Page 293: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-30 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that underground product piping connecting USTs or dispensers, containing motor fuel, are not routed under buildings whenever feasible (except used oil UST piping with an inside fill may be permitted subject to approval by the Office of the State Fire Marshal on the applicable permit).

ST.30.7.IL. USTs inside or under buildings are subject to specific requirements (41 IAC 170.545) [Revised May 1999].

Verify that no one deposits petroleum, petroleum products, hazardous substances or regulated substances into any UST system unless evidence is displayed that the UST system is in compliance with the applicable rules of 35 Ill. Adm. Code 170.

Verify that no one deposits petroleum, petroleum products, hazardous substances or regulated substances into any UST system that displays evidence that the UST system is not in compliance with the applicable rules of the OSFM.

ST.30.8.IL. USTs must bear evidence of compliance prior to introduction of product (41 IAC 171.50, 171.90, 171.110, and 171.120) [Added June 2000].

Verify that no person deposits petroleum, petroleum product, hazardous substances or regulated substances into any UST system unless evidence is displayed that the UST system is in compliance with state regulations.

(NOTE: A depositor may make one deposit of a regulated substance to a newly installed or newly relined tank to provide ballast.)

(NOTE: Evidence of Compliance Status for motor fuel dispensing facilities consists of a tag or decal issued by the OSFM. The tag or decal will be either:

- red: indicating non-compliance - green: indicating compliance - yellow: indicating exempt.)

Verify that, for motor fuel dispensing tanks, evidence of Compliance Status is either affixed to the window closest to the main entry of the motor fuel dispensing facility or, if a window is not available, to the inside window of the dispenser cabinet.

(NOTE: If more than one UST system is located at the facility, and some but not all UST systems are in compliance, the OSFM will issue a Green decal or tag, which will be affixed as provided above, and will issue individual Red decals or tags for each of the non-compliant UST systems, which will be affixed directly onto the fill pipe of the non-compliant UST system or near the fill pipe of the non-compliant UST system at a location approved by the OSFM.)

Verify that, for non-motor fuel dispensing tanks, evidence of Compliance Status is either affixed to the fill pipe of the UST system or near the fill pipe at a location agreed to by the representative of the OSFM.

Verify that, for non-motor fuel dispensing tanks, if the tag or decal affixed to the fill pipe is Red, the fill pipe is secured to avoid the product being accidentally

Page 294: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-31 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

deposited in the UST system.

Verify that depositors of hazardous substances and petroleum and petroleum products, other than motor fuel, first ascertain if evidence of non-compliance, a Red decal or tag, is affixed to the UST system.

Verify that depositors of Heating Oil first ascertain if evidence of non-compliance, a Red decal or tag, is affixed to the UST system.

(NOTE: Until 1 August 2001, if no Red decal or tag is present, the person may deposit into the UST system. After August 1, 2001, the person may not deposit into any UST system that does not display Evidence of Compliance Status.)

Page 295: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-32 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.35. NEW OR UPGRADED USTs

(NOTE: A new UST system is one that will be used to contain a regulated substance and for which installation has commenced after 21 April 1989.) (NOTE: No later than 22 December 1998, all existing UST systems must comply with either new UST performance standards, the upgrading requirements of this section, temporary closure, or removal requirements.)

ST.35.1.IL. New USTs must meet specific material, construction and installation standards (41 IAC 170.420(a) and (c)(3)).

Verify that, to prevent penetration of the tanks bottom, all non-metallic tanks are equipped with steel striker plates on the tank bottom immediately below any opening which might be used for taking dipstick measurements.

Verify that metallic tanks are thoroughly coated on the outside with suitable rust-resisting dielectric material.

Verify that metallic tanks are not surrounded or covered by cinders or other material of corrosive effect.

Verify that steel tanks are set on firm foundations and surrounded with at least 12 in of non-corrosive inert material such as clean sand or gravel, well-tamped in place.

Verify that the tank is placed in the hole with care, since dropping or rolling the tank into the hole can break a well, puncture or damage the tank or scrape off the protective coating of coated tanks.

Verify that steel tanks are covered with a minimum of 3 ft of earth.

(NOTE: USTs existing on 1 October 1985 must have been buried so that the top of the tank is not less than 2 ft below the surface of the ground, or under at least 12 in. of earth and a slab of reinforced concrete not less than four in. in thickness; the slab must set on a firm, well-tamped earth foundation and extend at least one foot beyond the outline of the tank in all directions. When the asphaltic or reinforced paving is used as part of the protection, it must extend at least one foot horizontally beyond the outline of the tank in all directions.)

ST.35.2.IL. The installation of new UST systems must be certified (41 IAC 170.420(d)).

Verify that the installation of a new UST system has been certified by either:

- the installer has been certified by the tank and piping manufacturer, or - the installer has been certified or licensed by the Office of the State Fire

Marshal, or - the installation of the UST has been inspected and certified by a state

registered professional engineer experienced in UST installation, or - all work listed in the manufacturer’s installation checklist has been

completed, or

Page 296: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-33 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- the installation is certified by the Office of the State Fire Marshal to be effective in protecting human health and the environment.

ST.35.3.IL. Piping associated with new USTs must meet specific material, construction and installation standards (41 IAC 170.421(d)).

Verify that piping systems in contact with the ground that routinely contains regulated substances meet the following requirements:

- the piping is constructed of fiberglass-reinforced plastic or of steel that is cathodically protected in the following manner:

- it is coated with a suitable dielectric coating - field-installed cathodic protection systems are designed by a corrosion expert - impressed current systems are designed to allow determination of current

operating status - the piping is constructed of material determined by the Office of the State

Fire Marshal to prevent the release or threatened release of regulated substances.

ST.35.4.IL. The upgrade of UST systems must meet specific requirements (41 IAC 170.430(b)(c)(d)).

Verify that when steel tanks are upgraded:

- an interior lining is installed, or - cathodic protection is added to the system, or - an interior lining is combined with cathodic protection.

Verify that metal piping that routinely contains regulated substances and is in contact with the ground is upgraded to include cathodic protection.

Verify that UST system upgrades include the addition of spill and overfill prevention equipment.

Page 297: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-34 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.95. CHANGES IN SERVICE OR CLOSURE OF USTs

ST.95.1.IL. A change-in-service must meet specific operational requirements (41 IAC 170.630).

Verify that, before a change-in-service, owners or operators empty and clean the tank by removing all liquid and accumulated sludge, and conduct a site assessment.

(NOTE: Continued use of a UST system to store a non-regulated substance (so that it is no longer classified as a UST system) is considered a change-in-service. However, a change-in-service may only occur during the first two years, commencing with the date of installation of the tank.)

(NOTE: A change-in-service also consists of a conversion of a petroleum UST to a hazardous substance UST and vice versa.)

Verify that a non-UST system tank (i.e., one which is used to store a non-regulated substance), is not converted to a UST system tank unless the tank has been re-certified and is in compliance with all applicable upgrade requirements for the new UST systems.

ST.95.2.IL. Owners/ operators must perform a site assessment for a change-in-service or removal of a UST system (41 IAC 170.640).

Verify that after removal or a change-in-service is completed, the owner or operator performs a site assessment by measuring for the presence of a release where contamination is most likely to be present at the UST site.

(NOTE: In selecting sample types, sample locations and measurement methods, the owner or operator must consider the method of removal, the nature of the stored substance, the type of backfill, the depth to groundwater and other factors appropriate for identifying the presence of a release.)

(NOTE: The requirements of this checklist item are satisfied if vapor monitoring or groundwater monitoring is operating at the time of removal and indicates no release has occurred.)

(NOTE: The Office of the State Fire Marshal provides no additional guidance to performing a site assessment. This is the responsibility of the owner or operator.)

Verify that if contaminated soils, contaminated groundwater, or free product as a liquid or vapor, resulting from a UST system release, is discovered, owners or operators begin initial response and initial abatement (see the TEAM Guide, sections ST.60. through ST.75.).

Page 298: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-35 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.95.3.IL. Abandoned UST systems must undergo closure according to specific requirements (41 IAC 170.670(a) through (c)).

Verify that when an underground storage tank has been out of operation for 12 consecutive months, the owner of the tank removes it within the immediate subsequent 12-mo period.

Verify that during removal, the owner/operator or contractor:

- removes all petroleum or hazardous substances and all accumulated sludges from the tank and connecting lines

- disconnects piping at all tank openings - removes all sections of connecting lines which are not to be used further, and

caps or plugs all tank openings - removes tank from ground.

Verify that before removal (or at any time thereafter, as determined by the Office

of the State Fire Marshal), the tank is gas freed on the premises, or is transported to an area not accessible to the public and the gas freeing completed at that location.

(NOTE: In the event of a tank releasing or suspected of releasing a flammable or combustible liquid, the tank must be gas freed on the premises prior to removal from the excavation zone, and not gas freed elsewhere.)

(NOTE: The requirement for removal is subject to the following exceptions: - if the tank is placed in a “temporary out-of-service” status, upon termination

of such status, the tank shall be removed - if there is a “change-in-service” to a non-regulated substance during the first

12-mo period - a waiver to “abandoned-in-place,” is issued - USTs that have not been in operation at any time after 1 January 1974, may

not be required to be removed, unless the Office of the State Fire Marshal has determined that a release from the USTs poses a current or potential threat to human health and the environment

- heating oil USTs, for consumptive use on the premises where stored, do not have to be removed, unless the Office of the State Fire Marshal has determined that a release from the USTs poses a current or potential threat to human health and the environment).

Verify that, if a tank is to be disposed of as junk, it is retested for combustible or

flammable vapors, and if necessary, rendered gas free.

Verify that after removal and before releasing to junk dealer, a sufficient number of holes or openings (at least two percent of the total surface area of the tank) are made in it to render it inoperative for further use as a UST.

(NOTE: If the tank last contained lead gasoline, an unknown petroleum or a hazardous substance, it may only be scrapped as junk or re-certified.)

Page 299: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-36 Storage Tank Management

COMPLIANCE CATEGORY: STORAGE TANK MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ST.95.4.IL. UST systems closed prior to 1 October 1985 must provide documentation to the State Fire Marshal (41 IAC 170.670(a) through (c)).

Verify that owners of tanks outside the jurisdiction of the City of Chicago filled with inert material prior to 1 October 1985 provide documentation of fill material and date of fill, upon request by the Office of the State Fire Marshal.

(NOTE: The documentation shall be a receipt or a written statement from the contractor who did the fill, a statement from the inspector who inspected the tank, or a written statement from anyone designated by the State Fire Marshal or the Director of the Division of Petroleum and Chemical Safety. Tanks, inside the jurisdiction of the City of Chicago, which were abandoned-in-place, prior to 28 July 1989 (the date of repeal of the home rule by the City over USTs) in accordance with City laws, regulations or ordinances, need not be removed.)

Page 300: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-37 Storage Tank Management

Page 301: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

10-38 Storage Tank Management

Appendix 10-1

Maximum Deflection Standards for Nonmetallic USTs (Source: 41 IAC 170.65(d))

Tank Diameter (ft) Maximum Deflection (in.)

6 5/8 8 1

10 1-1/2 12 1-1/2

Page 302: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

11-1 Toxic Substances Management

SECTION 11

TOXIC SUBSTANCES MANAGEMENT

Illinois Supplement, June 2000 This section covers the Illinois state requirements for Toxic Substances Management and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Definitions

• Agency - Illinois Environmental Protection Agency (IEPA) (Title 35, Illinois Administrative Code, Section 228.103 (35 IAC 228.103)).

• Asbestos - any fiber or any mixture containing fiber of hydrated silicate mineral which, on the basis of its

crystalline structure, falls into one of two categories (35 IAC 228.103): 1. pyroxenes - chrysotile fiber 2. amphiboles - crocidolite, amosite, tremolite, actinolite, or anthophilite fiber.

• Debris - asbestos-containing waste produced by the demolition of a structure (35 IAC 228.103). • Department:

1. For the purposes of the lead based paint requirements, the Department of Public Health of the State of Illinois (77 IAC 845.10) [Added May 1998]

2. For the purposes of the radon management requirements, the Illinois Department of Nuclear Safety (32 IAC 420.20) [Added May 1998].

• Dwelling Risk Assessment - an on-site investigation to determine the existence, nature, severity, and location of

lead-based paint hazards and the provision of a report, by the individual or the firm conducting the risk assessment, explaining the results of the investigation and options for reducing lead-based paint hazards (77 IAC 845.10) [Added May 1999].

• Inspection - a surface-by-surface investigation to determine the presence of lead-based paint and the provision

of a report explaining the results of the investigations (77 IAC 845.10) [Added May 1998]. • Intact Surface - a surface with no loose, peeling, chipping or flaking paint. Intact surfaces that are painted must

be free from crumbling, cracking or falling plaster and should not have any holes. Intact surfaces must not be damaged or worn down in any way that would make paint from the damaged area accessible to children (77 IAC 845.10) [Added May 1998].

• Lead Abatement - any activity that will result in the removal of windows, walls, floors, ceilings or exterior

surfaces which may result in the creation of a hazardous level of leaded chips, flakes, dust or any other form of leaded substance that can be ingested or inhaled during such activity (77 IAC 845.10) [Added May 1998].

• Lead Abatement Supervisor - any person employed by a lead abatement contractor and licensed by the

Department to perform lead abatement and mitigation, and supervise lead abatement workers who perform lead abatement and mitigation ("Lead Abatement Supervisor" was formerly known as "Lead Abatement Contractor/Supervisor") (77 IAC 845.10) [Added May 1998; Revised May 1999].

• Lead Bearing Substance - any dust on surfaces or in furniture or other nonpermanent elements of the dwelling

and any paint or other surface coating material containing more than five-tenths of one percent (0.5%) lead by

Page 303: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

11-2 Toxic Substances Management

weight (calculated as lead metal) in the total nonvolatile content of liquid paint. The term "lead bearing substance" also includes lead bearing substances containing greater than one milligram per square centimeter or any lower standard for lead content in residential paint as may be established by federal law or regulation; or more than 1 milligram per square centimeter in the dried film of paint or previously applied substance; or object containing lead in excess of the amount specified in this Part or a lower standard for lead as may be established by federal regulation (77 IAC 845.10) [Added May 1998].

• Lead Hazard - a lead bearing substance that poses an immediate health hazard to humans (77 IAC 845.10)

[Added May 1998]. • Lead Inspector - an individual who has been trained by a Department approved training program to conduct

inspections, sample for the presence of lead in dust and soil, and conduct abatement clearance testing (77 IAC 845.10) [Added May 1998].

• Lead Management Plan - a written statement that describes how an intact surface with lead-based paint will be

monitored to assure that, if the intact surface becomes defective, the defective surface will be abated or mitigated (77 IAC 845.10) [Added May 1998].

• Lead Mitigation - the remediation of a lead hazard so that the lead bearing substance does not pose an

immediate health hazard to humans. A lead hazard is deemed to have been mitigated if the surface that is the source of the lead hazard is no longer in a condition that produces a hazardous level of leaded chips, flakes, dust or any other form of leaded substances, that can be ingested or inhaled by humans; or if the leaded surface is accessible to children, the surface coating is covered or the access to the leaded surface by children is otherwise prevented (77 IAC 845.10) [Added May 1998].

• Lead Poisoning - the conditions of having blood levels in excess of those considered safe under this Part (see

"permissible limits") and federal rules and regulations (77 IAC 845.10) [Added May 1998]. • Lead Risk Assessor - an individual who has been trained by a Department approved training program to conduct

risk assessments, sample for the presence of lead in dust and soil and conduct abatement clearance testing (77 IAC 845.10) [Added May 1998].

• Radon - any of the gaseous radioactive decay products of uranium or thorium (32 IAC 420.20) [Added May

1998]. • Radon Progeny - any combination of the radioactive decay products of radon (32 IAC 420.20) [Added May

1998]. • Residential Building - any room, group of rooms, or other interior areas of a structure designed or used for

human habitation; common areas accessible by inhabitants; and the surrounding property or (77 IAC 845.10) [Added May 1998].

• Waste - any asbestos-containing matter which has been or is intended to be discarded (35 IAC 228.103). • Work Area - exterior areas where lead abatement activities are conducted (77 IAC 845.10) [Added May 1998]. • Work Site - the room or rooms undergoing lead abatement activities in a single family dwelling or the room or

rooms and common area of a residential building (77 IAC 845.10) [Added May 1998].

Page 304: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

11-3 Toxic Substances Management

TOXIC SUBSTANCES MANAGEMENT GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: PCB Management Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Missing Checklist Items T1.2.1.IL. Asbestos Management

Missing Checklist Items T2.2.1.IL. Renovation and Demolition of Asbestos-Containing Structures

T2.5.1.IL. through T2.5.4.IL.

Radon Management T3.1.1.IL. and T3.1.2.IL. Missing Checklist Items T3.2.1.IL.

Lead-Based Paint Management T4.1.1.IL. through T4.1.3.IL. Missing Checklist Items T4.2.1.IL.

Page 305: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

11-4 Toxic Substances Management

COMPLIANCE CATEGORY: TOXIC WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

PCB MANAGEMENT T1.2. Missing Checklist Items

T1.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 306: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

11-5 Toxic Substances Management

COMPLIANCE CATEGORY: TOXIC WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ASBESTOS MANAGEMENT T2.2. Missing Checklist Items

T2.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 307: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

11-6 Toxic Substances Management

COMPLIANCE CATEGORY: TOXIC WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ASBESTOS MANAGEMENT

T2.5.1.IL. Emissions of asbestos fibers during construction must be con-trolled (35 IAC 228.133).

Verify that the cutting, trimming, fitting, or stripping of asbestos-containing materials (ACM) during the construction, alteration, or repair of a structure, which is done onsite in any area open to the atmosphere, is conducted within a special enclosure designed to prevent the escape of asbestos fiber from the immediate area of the enclosure.

Verify that the mechanical exhaustion of dust from such enclosures to the ambient air is prohibited, unless the exhaust system is equipped with a properly sized fabric filter for dust collection or an equivalent device as approved by the Agency.

T2.5.2.IL. Visible emissions of fiber-containing material are prohibited (35 IAC 228.134).

Verify that the facility does not emit visible emissions of fiber-containing material into any area open to the atmosphere.

T2.5.3.IL. Facilities must prevent the emission of ACM to circulating air (35 IAC 228.135).

Verify that ACM applied in the construction, alteration, or repair of a structure is coated with a sealant, provided with a cover, or installed to preclude emission of the ACM to the circulating air.

Verify that any plenum or other structure coated with or containing asbestos-containing insulation and used in the circulation of air in a building is thoroughly cleaned of all debris and waste insulation.

T2.5.4.IL. Facilities must reduce the emission of asbestos-containing dust during demolition of a structure (35 IAC 228.121(c) and (d), and 228.141)

Verify that, where the risk of public exposure to asbestos fiber from the dislodging of asbestos-containing materials is present, the facility does not demolish a structure unless specific safeguards, including, but not limited to, the following, are taken to reduce the emission of asbestos-containing dust:

- boilers and pipes and steel members insulated or fireproofed with asbestos-containing material, and other asbestos-lined surfaces where practicable, are wetted and stripped before toppling of walls is begun

- stripped asbestos waste is immediately bagged and disposed of - when demolition by toppling occurs, a reasonable enclosure for dust emission

control compatible with the character of the structure is used - any section or wall is adequately wet before demolition or toppling - asbestos-containing debris is not dropped or thrown from any floor, but is

transported by dust-tight chutes or buckets

Page 308: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

11-7 Toxic Substances Management

COMPLIANCE CATEGORY: TOXIC WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- asbestos-containing debris in chutes or buckets is sufficiently wetted to preclude dust dispersion at the point of discharge

- all asbestos-containing debris is thoroughly wetted before loading into trucks, vehicles, or containers

- during transport, asbestos waste is enclosed or covered so as to prevent dust dispersion

- asbestos-containing debris is disposed by burial at a sanitary landfill.

Verify that asbestos waste is immediately bagged and disposed of as follows:

- immediately vacuumed (or otherwise collected when vacuuming is impossible)

- placed in containers resistant to tearing or breaking under normal handling conditions

- containers are sealed and clearly marked as containing asbestos waste - containers are placed directly upon a vehicle for disposal by burial at a

sanitary landfill.

Verify that facilities are provided and procedures instituted and supervised that prevent the removal from the site of visible amounts of asbestos-containing material on the clothing of the employees.

Page 309: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

11-8 Toxic Substances Management

COMPLIANCE CATEGORY: TOXIC WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

T3.1. RADON MANAGEMENT

T3.1.1.IL. Radon detectors, analysts and mitigators must be licensed (Chapter 420 Illinois Consolidated Statutes, Section 44/25, and 32 IAC 422.30(a)) [Added May 1998].

Verify that persons who detect the presence of radon or radon progeny, perform laboratory analysis, or perform a service to reduce the presence of radon or radon progeny in the indoor atmosphere have been licensed by the Department.

(NOTE: This does not apply to persons selling or distributing, but not placing, radon sampling devices supplied by a laboratory if the results of the laboratory analysis are reported directly to the owner or occupant of the building sampled.)

(NOTE: This also does not apply to an individual, business entity, or government entity performing radon tests or mitigation on a building or real property that the individual, business entity, or government entity owns or leases.)

T3.1.2.IL. Radon licensees must meet reporting and recordkeeping requirements (32 IAC 422.110) [Added May 1999].

Verify that all individuals licensed to perform radon measurements submit to the Department the results of all radon and radon progeny measurements on an annual basis.

Verify that records of radon measurements, mitigations, quality assurance programs, calibration measurements, equipment repairs and worker protection plans are retained by the licensee for at least 5 yr or the length of time of any warranty guarantees, whichever is longer.

Verify that all licensees report apparent non-compliance with either the Radon Industry Licensing Act or this Part to the Department in writing upon discovery.

Page 310: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

11-9 Toxic Substances Management

COMPLIANCE CATEGORY: TOXIC WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

RADON MANAGEMENT T3.2. Missing Checklist Items

T3.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 311: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

11-10 Toxic Substances Management

COMPLIANCE CATEGORY: TOXIC WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

T4.1. LEAD BASED PAINT MANAGEMENT

T4.1.1.IL. Lead abatement supervisors must ensure that all workers are licensed (77 IAC 845.32(a)) [Added May 1998; Revised May 1999].

Verify that the lead abatement supervisor has ensured that all workers are licensed.

T4.1.2.IL. Workers who remove or cover leaded soil must be licensed (77 IAC 845.29(a) [Added May 1999].

Verify that workers who remove or cover leaded soil are licensed.

T4.1.3.IL. Lead abatement supervisors must meet notification requirements (77 IAC 845.32(e)) [Added May 1999].

Verify that lead abatement supervisors notify the Department at least 10 working days or 14 calendar days prior to commencement of any lead abatement or mitigation projects.

Verify that notification is on a form provided by the Department or contains the same information required on the Department's form as follows:

- contractor's name and license number - date of project start time and end time - location of project - name, address, and phone number of owner of property being abated or

mitigated.

Page 312: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

11-11 Toxic Substances Management

COMPLIANCE CATEGORY: TOXIC WASTE MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

LEAD-BASED PAINT MANAGEMENT T4.2. Missing Checklist Items

T4.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 313: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-1 Wastewater Management

SECTION 12

WASTEWATER MANAGEMENT

Illinois Supplement, June 2000 This section covers the state requirements for Wastewater Management and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Definitions

• Aboveground Storage Tank - a storage tank that is not an underground storage tank (Title 35, Illinois Administrative Code, Section 615.102 (35 IAC 615.102)).

• Acute Toxicity - the capacity of any substance or combination of substances to cause mortality or other adverse

effects in an organism resulting from a single or short-term exposure to the substance (35 IAC 302.100). • Adverse Effect - any gross or overt effect on an organism, including but not limited to reversible histo-

pathological damage, severe convulsions, irreversible functional impairment and lethality, as well as any non-overt effect on an organism resulting in functional impairment or pathological lesions that may affect the performance of the whole organism, or that reduces an organism’s ability to respond to an additional challenge (35 IAC 302.100).

• Artificial Cooling Lake - any manmade lake, reservoir, or other impoundment, constructed by damming the flow

of a stream. that is used to cool the water discharged from the condensers of a steam-electric generating plant for recirculation in substantial part to the condensers (35 IAC 301.225).

• Authorization to Discharge - an authorization issued to an industrial user by a publicly owned treatment works

(POTW) that has an approved pretreatment program. The authorization may consist of a permit, license, ordinance or other mechanism as specified in the approved pretreatment program (35 IAC 310.110).

• Basin - the are tributary to the designated body of water (35 IAC 301.230). • BETX - the sum of the concentrations of benzene, ethylbenzene, toluene, and xylenes (35 IAC 620.110). • Calumet River System - the Calumet River, the Grand Calumet River, the Little Calumet River downstream from

its confluence with the Grand Calumet, the Calumet-Sag Channel and the Calumet Harbor Basin (35 IAC 301.245).

• Chicago River System - the Chicago River and its branches, the North Shore Channel, and the Chicago Sanitary

and Ship Canal (35 IAC 301.250). • Chronic Toxicity - the capacity of any substance or combination of substances to cause injurious or debilitating

effects in an organism that results from exposure for a time period representing a substantial portion of the natural life cycle of that organism, including but not limited to the growth phase, the reproductive phases or such critical portions of the natural life cycle of that organism (35 IAC 302.100).

• Combined Sewer - a sewer designed and constructed to receive both wastewater and land runoff (35 IAC

301.255).

Page 314: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-2 Wastewater Management

• Commencement of Construction - all necessary Federal, state, and local approvals have been obtained, and work at the site has been initiated and proceeds in a reasonable continuous manner to completion (35 IAC 615.102).

• Compliance Point - any point in groundwater designated as Class I through III groundwater at which a

contaminant released from the unit could pass underneath the unit boundary. There may be more than one compliance point for a particular unit (35 IAC 615.102).

• Construction - commencement of onsite fabrication, erection or installation of a treatment works, sewer, or

wastewater source; or the reinstallation at a new site of any existing treatment works, sewer, or wastewater source (35 IAC 301.265).

• Container - any portable device (including, but not limited to, 55-gal drums) in which material is stored, treated,

disposed of, or otherwise handled. This does not include a vehicle used to transport material (35 IAC 615.102). • Contaminant - any solid, liquid, or gaseous matter, any odor, or any form of energy, from whatever source (35

IAC 615.102). • Contamination - when used in connection with groundwater, means water pollution of such groundwater (35

IAC 615.102). • Effluent - any wastewater discharged, directly or indirectly, to the waters of the state or to any storm sewer, and

the runoff from land used for the disposition of wastewater or sludges, but does not otherwise include nonpoint source discharges such as runoff from land or any livestock management facility or livestock wastehandling facility (35 IAC 301.275).

• Freeboard - the vertical distance between the top of a tank or dike and the surface of the material contained

therein (35 IAC 615.102). • Free Liquids - liquids that readily separate from the solid portion of a waste under ambient temperature and

pressure (35 IAC 615.102). • Groundwater - underground water that occurs within the saturated zone and geologic materials where the fluid

pressure in the pore space is equal to or greater than atmospheric pressure (35 IAC 615.102). • Hazardous Waste - a waste, or combination of wastes that because of its quantity, concentration, or physical,

chemical, or infectious characteristics may cause or significantly contribute to an increase in mortality or an increase in serious, irreversible, or incapacitating reversible, illness; or pose a substantial present or potential hazard to human health or the environment when improperly treated, stored, transported, or disposed of, or otherwise managed, and that has been identified by characteristics or listing as a “hazardous waste” (35 IAC 615.102).

• IEPA - Illinois Environmental Protection Agency. • Incompatible Material - a material that may cause corrosion or decay of containment materials; or, when

commingled with another material, produces heat or pressure, fire, explosion, violent reaction, toxic dusts, mists, fumes or gases, or flammable fumes or gases (35 IAC 615.102).

• Industrial User - a source of indirect discharge and includes any person that meets any of the following criteria

(35 IAC 310.110): 1. discharges toxic pollutants 2. is subject to a categorical standard 3. discharges more than 15 percent of the total hydraulic flow received by the POTW treatment plant 4. discharges more than 15 percent of the total biological loading of the POTW treatment plant as measured

by the 5-day biochemical oxygen demand (BOD5)

Page 315: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-3 Wastewater Management

5. has caused pass through or interference 6. has presented an imminent endangerment to the health or welfare of persons.

• Industrial Wastes - any solid, liquid, or gaseous wastes resulting from any process of industry, manufacturing,

trade, or business or from the development, processing, or recovery, except for agricultural crop raising, or any natural resources (35 IAC 301.285).

• Industrial Wastewater - waste of a liquid nature discharged by an industrial user to a sewer tributary to a

POTW. • Interstate Waters - all waters that cross or form part of the border between Illinois and other states (35 IAC

301.295). • Intrastate Waters - all the waters of Illinois that are not interstate waters (35 IAC 301.300). • Land Application Facility or Unit - an area where wastes are agronomically spread over or disked into land or

otherwise applied so as to become incorporated into the soil surface (35 IAC 615.102). • Land Runoff - water reaching the waters of the state as runoff resulting from precipitation (35 IAC 301.305). • Land Treatment - the application of waste onto or incorporation of waste into the soil surface. For the purpose of

these regulations, a land application facility is a land treatment facility (35 IAC 615.102). • Landfill - a unit or part of a facility in or on which waste is placed and accumulated over time for disposal, and

which is not a land application facility, a surface impoundment or an underground injection well (35 IAC 615.102).

• Landscape Waste - all accumulations of grass or shrubbery cuttings, leaves, tree limbs and other materials

accumulated as the result of the care of lawns, shrubbery, vines, and trees (35 IAC 615.102). • Leachate - any liquid, including suspended components in the liquid, that has percolated through or drained

from a material (35 IAC 615.102). • Liner - a continuous layer of natural or manmade materials beneath or on the side of a surface impoundment,

landfill, landfill cell, waste pile, or storage pile that restricts the downward or lateral escape of waste, waste constituents, leachate, or stored materials (35 IAC 615.102).

• Marine Toilet - any toilet on or within any watercraft (35 IAC 301.310). • Mixing Zone - a portion of the waters of the state identified as a region within which mixing is allowed (35 IAC

302.100). • Modification - any of the following (35 IAC 301.315):

1. any physical change in a treatment works that involves different or additional processes or equipment or that increases or decreases the capacity or efficiency of the treatment works

2. any change in the number or location of points where effluent is discharged, directly or indirectly, to the waters

3 any change in any components of a sewer system that alters the quantity of wastewater capable of being conveyed, or that increases or decreases the quantity of wastewater capable of being discharged at overflow or bypass structures

4. any increase in quantity or strength of a discharge from any wastewater source, unless such increase does not exceed an upper limit specifically allowed by an existing permit granted by the IEPA and does not involve any additional contaminants contained in regulation standards that are not itemized and approved in an existing IEPA permit.

Page 316: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-4 Wastewater Management

• New Potential Primary Source - a potential primary source that is not in existence or construction has not

commenced as of 1 January 1988; or, a potential primary source that expands laterally beyond the currently permitted boundary (or if the source is not permitted, the boundary in existence) as of 1 January 1988; or a potential primary source that is part of a facility that undergoes major reconstruction (35 IAC 616.102).

• New Potential Secondary Source - a potential secondary source that is not in existence or construction has not

commenced as of 1 July 1988; or, a potential secondary source that expands laterally beyond the currently permitted boundary (or if the source is not permitted, the boundary in existence) as of 1 July 1988 other than an expansion for handling of livestock waste or for treating domestic wastewaters; or, a potential secondary source that is part of a facility that undergoes major reconstruction (35 IAC 616.102).

• NPDES - the National Pollution Discharge Elimination System for issuing, establishing conditions for and

denying permits under Section 402 of the Clean Water Act (35 IAC 301.325). • Onsite - the same or geographically contiguous property that may be divided by public or private right-of-way,

provided the entrance and exit between the properties is at a crossroads intersection and access is by crossing as opposed to going along the right-of-way. Noncontiguous properties owned by the same person but connected by a right-of-way that he controls and to which the public does not have access is also considered onsite property (35 IAC 615.102).

• Operator - the person responsible for the operation of a site, facility, or unit (35 IAC 615.102). • Other Wastes - garbage, refuse, wood residues, sand, lime, cinders, ashes, offal, night soil, silt, oil, tar, dye

stuffs, acids, chemicals and all other substances not sewage or industrial waste whose discharge would cause water pollution or a violation of the effluent or water quality standards (35 IAC 301.330).

• Person - any individual, partnership, co-partnership, firm, company, corporation, association, joint stock

company, trust, estate, political subdivision, state agency, or any other legal entity, or their legal representative, agent or assigns. This definition includes the United States government, the State of Illinois and their political subdivisions (35 IAC 301.335).

• Pile - any noncontainerized accumulation of solid, non-flowing material that is used for treatment, storage, or

disposal (35 IAC 615.102). • Pollutant - discharged into water any dredged spoil, solid waste, incinerator residue, sewage, garbage, sewage

sludge, munitions, chemical wastes, biological materials, radioactive materials, heat, wrecked or discarded equipment, rock, sand cellar dirt, industrial municipal waste, or agricultural waste. This term does not mean (35 IAC 301.340):

1. sewage from vessels 2. water, gas, or other material that is injected into a well to facilitate production and disposed of in a well, if

the well, used either to facilitate production or for disposal purposes is approved by the Department of Mines and Minerals, and if the Department of Mines and Minerals determines that such injection or disposal will not result in the degradation of ground or surface water resources.

• Population Equivalent - a term used to evaluate the impact of industrial or other waste on a treatment works or

stream. One population equivalent is 100 gal (380 L) of sewage per day containing 0.17 lb (77 gr) of BOD5 and 0.20 lb (91 gr) of suspended solids. The impact on a treatment works is evaluated as the equivalent of the highest of the three parameters. Impact on a stream is the higher of the BOD5 and suspended solids parameters (35 IAC 301.305).

• Potable - generally fit for human consumption in accordance with accepted water supply principles and

practices (35 IAC 620.110).

Page 317: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-5 Wastewater Management

• Potential Primary Source - any unit at a facility or site not currently subject to a removal or remedial action that (35 IAC 616.102):

1. is utilized for the treatment, storage, or disposal of any hazardous or special waste not generated at the site 2. is utilized for the disposal of municipal waste not generated at the site, other than landscape waste and

construction and demolition debris 3. is utilized for the landfilling, land treating, surface impounding or piling of any hazardous or special waste

that is generated on the site or at other sites owned, controlled or operated by the same person 4. stores or accumulates at any time more than 75,000 lb aboveground, or more than 7500 lb belowground,

of any hazardous substance. • Potential Route - abandoned and improperly plugged wells of all kinds, drainage wells, all injection wells,

including closed loop heat pump wells, and any excavation for the discovery, development or production of stone, sand, or gravel.

• Potential Secondary Source - any unit at a facility or site not currently subject to a removal or remedial action,

other than a potential primary source, that (35 IAC 616.102): 1. is utilized for the landfilling, land treating, or surface impounding of waste that is generated on the site or

at other sites owned, controlled, or operated by the same person, other than livestock and landscape waste, and construction and demolition debris

2. stores or accumulates at any time more than 25,000 lb but not more than 75,000 lb aboveground, or more than 2500 lb but not more than 7500 lb belowground, of any hazardous substance

3. stores or accumulates at any time more than 25,000 gal aboveground, or more than 500 gal belowground, of petroleum, including crude oil or any fraction thereof that is not otherwise specifically listed or designated as a hazardous substance

4. stores or accumulates at any time more than 50,000 lb of any de-icing agent 5. is utilized for handling livestock waste or for treating domestic wastewaters other than private sewage

disposal systems.

• Pretreatment Works - a treatment works designed and intended for the treatment of wastewater from an indirect discharge or industrial user before introduction into a sewer system tributary to a publicly owned or publicly regulated treatment works (35 IAC 301.305).

• Primary Contact - any recreational or other water use in which there is prolonged and intimate contact with the

water involving considerable risk of ingesting water in quantities sufficient to pose a significant health hazard, such as swimming and water skiing (35 IAC 301.305).

• Public and Food Processing Water Supply - any water use in which water is withdrawn from surface waters of

the state for human consumption or for processing of food products intended for human consumption (35 IAC 301.360).

• Publicly Owned Treatment Works (POTW) - a treatment works owned by a municipality, sanitary district,

county or state agency, and treats domestic and industrial wastes collected by a publicly owned or regulated sewer system. Industrial treatment works that are publicly owned and financed by bond issues of public agencies are not included in this definition (35 IAC 301.365).

• Publicly Regulated Treatment Works - those otherwise private companies that are regulated as public utilities

engaged in the disposal of domestic and industrial wastes and regulated as such by the Illinois Commerce Commission (35 IAC 301.370).

• Reactive Material - a material that meets one or more of the following criteria (35 IAC 615.102):

1. it is normally unstable and readily undergoes violent change without detonating 2. it reacts violently with water 3. it forms potentially explosive mixtures with water

Page 318: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-6 Wastewater Management

4. when mixed with water, it generates toxic gases, vapors, or fumes in a quantity sufficient to present a danger to human health or the environment

5. it is capable of detonation or explosive reaction if it is subject to a strong initiating source, or if heated under confinement

6. it is readily capable of detonation or explosive decomposition or reaction at standard temperature and pressure

7. it is a forbidden explosive, a Class A explosive, or a Class B explosive.

• Regulated Entity - a facility or unit regulated for groundwater protection by any state or federal agency (35 IAC 620.110).

• Regulated Recharge Area - a compact geographic area with geology that renders a potable resource

groundwater particularly susceptible to contamination, as determined by the Illinois Pollution Control Board (35 IAC 620.110).

• Resource Groundwater - groundwater that is presently being, or in the future is capable of being, put to

beneficial use by reason of being of suitable quality (35 IAC 620.110). • Sanitary Sewer - a sewer that carries wastewater together with incidental land runoff (35 IAC 301.375). • Secondary Contact - any recreational or other water use in which contact with the water is either incidental or

accidental and the probability of ingesting appreciable quantities of water is minimal, such as fishing, commercial and recreational boating, and any limited contact incident to shoreline activity (35 IAC 301.380).

• Secondary Containment Structure - any structure or basin intended to contain spills and prevent runoff or

leaching from piles, containers, or tanks and related piping (35 IAC 615.102). • Setback Zone - a designated geographic area containing a potable water supply well or a potential source or

potential route having a continuous boundary and within which certain prohibitions or regulations are applicable in order to protect groundwaters (35 IAC 615.102).

• Sewage - water-carried human and related wastes from any source (35 IAC 301.385). • Sewer - a stationary means of transport or stationary system of transport, excluding natural waterways,

constructed and operated for the purpose of collecting and transporting wastewater or land runoff, or both (35 IAC 301.390).

• Significant Industrial User - as follows (35 IAC 310.110):

1. all industrial users subject to categorical pretreatment standards 2. any other industrial user that discharges an average of 25,000 gal/day or more of process wastewater to

the POTW (excluding sanitary, noncontact cooling and boiler blowdown wastewater), contributes a process wastestream that makes up 5 percent or more of the average dry weather hydraulic or organic capacity of the POTW treatment plant; or is designated as such by the Control Authority.

• Sludge - any solid, semisolid, or liquid waste generated from a municipal, commercial, or industrial wastewater treatment plant, water supply treatment plant, or air pollution control facility or any other such waste having similar characteristics and effects (35 IAC 301.395).

• Special Waste - any industrial process waste, pollution control waste, or hazardous waste (35 IAC 615.102). • Storage - the holding or containment of a material, either on a temporary basis or for a period of years, in such a

manner as not to constitute disposal of such material (35 IAC 615.102). • STORET - the national storage and retrieval water quality data system of the USEPA (35 IAC 301.405).

Page 319: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-7 Wastewater Management

• Storm Sewer - a sewer intended to receive only land runoff (35 IAC 301.410). • Surface Impoundment - a natural topographical depression, manmade excavation, or diked area that is designed

to hold liquid wastes or wastes containing free liquids (35 IAC 615.102). • Surface Water - all waters that are open to the atmosphere (35 IAC 615.102). • Tank - a stationary device, designed to contain an accumulation of material that is constructed of nonearthen

materials that provide structural support. This does not include areas used to accumulate materials prior to pumping to tanks or containers or associated piping; or, vehicles used to transport materials (35 IAC 615.102).

• Toxic Substance - a chemical substance that causes adverse effects in humans, or in aquatic or terrestrial animal

or plant life. Toxic substances include those substances listed in 40 CFR 302.4 or any chemical substance as defined by the Illinois Chemical Safety Act (35 IAC 302.100).

• Treatment - any method, technique, or process, including neutralization, designed to change the physical,

chemical, or biological character or composition of any material so as to neutralize the material, recover energy or material resources from the material; or, render the material nonhazardous, less hazardous, safer to transport, store or dispose of; or, amenable for recovery, storage, or reduced volumes (35 IAC 615.102).

• Treatment Works - individually or collectively those constructions or devices (except sewers, and except

constructions or devices used for the pretreatment of wastewater prior to its introduction into publicly owned or regulated treatment works) used for collecting, pumping, treating, or disposing of wastewaters or for the recovery of byproducts from such wastewater (35 IAC 301.415).

• Underground Waters - any waters of the state located beneath the surface of the earth (35 IAC 301.420). • Unit Boundary - a line at the land’s surface circumscribing the area, above which or below which waste,

pesticides, fertilizers, road oils, or de-icing agents will be placed during the active life of the facility. The space taken up by any liner, dike, or other barrier designed to contain waste, pesticides, fertilizers, road oils, or de-icing agents falls within the unit boundary (35 IAC 615.102).

• Upset - an exceptional incident in which there is unintentional and temporary noncompliance with categorical

pretreatment standards because of factors beyond the reasonable control of the industrial user. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of preventive maintenance, or careless or improper operation (35 IAC 310.901).

• Waste - any garbage, sludge from a waste treatment plant, water supply treatment plant, or air pollution control

facility or other discarded material, including solid, liquid, semi-solid, or contained gaseous material resulting from industrial, commercial, mining and agricultural operations, and from community activities excluding industrial discharges covered by an NPDES permit; or, source, spent nuclear, or by-product materials defined by the Atomic Energy Act of 1954 (35 IAC 615.102).

• Waste Pile - a pile consisting of waste that has a total volume greater than 10 yd3 or within which the waste

remains for more than 90 days (35 IAC 615.102). • Wastewater - Sewage, industrial waste, or other waste, or any combination of these, whether treated or

untreated, plus any admixed land runoff (35 IAC 301.425). • Wastewater Source - any equipment, facility, or other source of any type whatsoever that discharges wastewater,

directly or indirectly to the waters of the state (35 IAC 301.430).

Page 320: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-8 Wastewater Management

• Watercraft - every type of boat, ship or barge used or capable of being used as a means of transportation on water (35 IAC 301.435).

• Waters - all accumulations of water, surface and underground, natural, and artificial, public and private, or parts

thereof, that are wholly or partially within, flow through, or border upon the State of Illinois, except that sewers and treatment works are not included except as specially mentioned; provided, that nothing herein contained shall authorize the use of natural or otherwise protected waters as sewers or treatment works except that in-stream aeration under Illinois Environmental Protection Agency (IEPA) permit is allowable (35 IAC 301.440).

• Well - a bored, drilled or driven shaft, or dug hole, the depth of which is greater than the largest surface

dimension (35 IAC 615.102). • Zone of Initial Dilution - a portion of a mixing zone within which acute toxicity standards need not be met (35

IAC 302.100).

Page 321: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-9 Wastewater Management

WASTEWATER MANAGEMENT GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: Missing Checklist Items WA.2.1.IL. Discharges to the Environment WA.5.1.IL. through WA.5.8.IL. Permits

NPDES WA.10.1.IL. and WA.10.2.IL. State Permits WA.15.1.IL. and WA.15.2.IL.

Treatment Works WA.20.1.IL. and WA.20.2.IL. Discharges to a POTW/FOTW

Pretreatment Standards WA.30.1.IL. and WA.30.2.IL. Sewage Systems

Marine Facilities WA.100.1.IL. Watershed Protection Programs

Existing Facilities in Setback Zones or Regulated Recharge Areas

Existing Facilities: Surface Impoundments

WA.150.1.IL. and WA.150.2.IL.

Existing Facilities: Waste Piles WA.150.3.IL. Existing Facilities: Underground Storage Tanks

WA.150.4.IL.

New Facilities in Setback Zones or Regulated Recharge Areas

New Facilities: Surface Impoundments

WA.150.5.IL. through WA.150.8.IL.

New Facilities: Onsite Waste Piles WA.150.9.IL.

GUIDANCE FOR APPENDIX USERS REFER TO APPENDIX NUMBERS: REFER TO APPENDIX TITLES:

12-1 Effluent Concentration Standards

Page 322: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-10 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WA.2. MISSING CHECKLIST ITEMS

WA.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 323: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-11 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WA.5. DISCHARGES TO THE ENVIRONMENT

(NOTE: Numerical effluent standards do not require users to clean up contamination caused essentially by upstream sources or to require treatment when only traces of contaminants are added to the background.) (NOTE: There are additional site specific effluent standards for specific treatment plants, plant discharges, and counties.)

WA.5.1.IL. Dilution of the effluent to meet standards is not an acceptable form of treatment (35 IAC 304.102).

Verify that the facility does not use dilution of the effluent from a treatment works or from any wastewater sources a method of treatment of wastes in order to meet the standards set forth in this Part.

(NOTE: It is the obligation of any person discharging contaminants of any kind to the waters of the state to provide the best degree of treatment of wastewater consistent with technological feasibility, economic reasonableness and sound engineering judgment.)

WA.5.2.IL. Facilities must not allow offensive discharges (35 IAC 304.106).

Verify that effluents do not contain settleable solids, floating debris, visible oil, grease, scum, or sludge solids.

Verify that color, odor, and turbidity are reduced to below obvious levels.

WA.5.3.IL. Facilities must meet effluent standards for deoxygenating wastes (35 IAC 304.120).

Verify that effluents with an untreated waste load of 10,000 population equivalents or more, or effluents from a source discharging into the Chicago River System or into the Calumet River System, do not exceed a BOD5 level of 20 mg/L or a suspended solids level of 25 mg/L.

Verify that effluents discharged into the Lake Michigan Basin do not exceed a BOD5 level of 4 mg/L or a suspended solids level of 5 mg/L.

Verify that effluents containing deoxygenating wastes do not exceed a BOD5 level of 30 mg/L or a suspended solids level of 30 mg/L.

(NOTE: Treatment works employing three stage lagoon treatment systems which are properly designed, maintained and operated, and whose effluent has a dilution ratio no less than five to one, or who qualify for exceptions under subsection (c) [see the following NOTE], must not exceed 37 mg/1 of suspended solids.)

Verify that effluents with dilution ratios less than five to one do not exceed a BOD5 level of 10 mg/L or a suspended solids level of 12 mg/L.

(NOTE: Treatment works employing three stage lagoon treatment systems that meet the following conditions are exempt from the preceding paragraph:

Page 324: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-12 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- the waste source qualifies under one of the following categories: - any wastewater treatment works with an untreated waste load less than 2500

population equivalents, which is sufficiently isolated that combining with other sources to aggregate 2500 population equivalents or more is not practicable

- any wastewater treatment works in existence and employing third-stage treatment lagoons on 1 January 1986, whose untreated waste load is 5000 population equivalents or less and sufficiently isolated that combining to aggregate 500 population equivalents or more is not practicable

- any wastewater treatment works with an untreated waste load of 5000 population equivalents or less, which has reached the end of its useful life by 1 January 1987, and is sufficiently isolated that combining to aggregate 5000 population equivalents or more is not practicable

- any wastewater treatment works with an untreated waste load of 5000 population equivalents or less which has reached the end of its useful life and which has received an adjusted standard determination from the Board that it qualifies for a lagoon exemption

- the lagoons are properly constructed, maintained and operated - the deoxygenating constituents of the effluent do not, alone or in combination

with other sources, cause a violation of the applicable dissolved oxygen water quality standard.)

(NOTE: Compliance with the numerical standards for effluents containing

deoxygenating wastes are determined by the type and frequency of sampling prescribed by the NPDES permit for the discharge at the time of monitoring.)

WA.5.4.IL. Facilities must not contribute to an exceedance of effluent standards for fecal coliforms (35 IAC 304.121).

Verify that effluents that discharge to all general use waters do not exceed a fecal coliform level of 400/100 mL unless otherwise allowed by the IEPA as part of the NPDES program.

WA.5.5.IL. Facilities must not contribute to an exceedance of effluent standards for nitrogen (35 IAC 304.122). (35 IAC 304.121).

Verify that effluents that meet the following criteria do not exceed a level of 2.5 mg/L for total ammonia nitrogen as N during the months of April through October or 4 mg/L at all other times:

- discharged to the Illinois River, the Des Plaines River downstream of its confluence with the Chicago River System or the Calumet River System

- untreated waste load of 50,000 or more population equivalents.

Verify that discharge effluents that meet the following criteria do not exceed a level of 3.0 mg/L for total ammonia nitrogen as N:

- discharged to the Illinois River, the Des Plaines River downstream of its confluence with the Chicago River System or the Calumet River System

Page 325: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-13 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

- untreated waste loads that cannot be computed on a population equivalent basis and have an ammonia nitrogen discharge that exceeds 45.4 kg/day (100 lb/day).

WA.5.6.IL. Facilities must not contribute to an exceedance of effluent standards for phosphorus (35 IAC 304.123).

Verify that effluents that discharge into the Lake Michigan Basin do not exceed a phosphorus level as P of 1.0 mg/L.

Verify that effluents that discharge to a lake or reservoir with a surface area equal to or greater than 8.1 hectares (20 acres) do not exceed a phosphorus level of 1.0 mg/L.

Verify that effluents that discharge to any tributary of a lake or reservoir with a surface area equal to or greater than 8.1 hectares with an untreated waste load of 2500 or more population equivalents and does not utilize a third-stage lagoon treatment system, do not exceed a phosphorus level of 1.0 mg/L.

(NOTE: This does not apply to lakes or reservoirs including any side channel reservoir or other portion, that on an annual basis exhibit a mean hydraulic retention time of 0.05 yr (18 days) or less.)

(NOTES: Lakes or reservoirs do not include low level pools constructed in free flowing streams or any body of water that is an integral part of an operation that includes the application of sludge on land.)

WA.5.7.IL. Effluents must meet concentration limits for specific constituents (35 IAC 304.124).

Verify that effluents do not exceed the concentration levels of the constituents listed in Appendix 12-1.

WA.5.8.IL. Facilities must not contribute to an exceedance of effluent standards for pH (35 IAC 304.125).

Verify that the pH of the effluent is between 6.0 and 9.0.

(NOTE: Effluents that have continuous pH monitors may be outside the pH range provided that the excursion is for not more than 15 min in any day, is accidental, and is less than one pH unit above or below the listed range.)

(NOTE: The pH of an effluent may be greater than 9, if the elevated pH is caused by one of the following:

- algae in treatment lagoons with no upper pH limit - the addition of alkali in the wastewater treatment process to cause

precipitation of barium, cadmium, chromium, copper, lead, manganese, zinc, or other materials requiring an elevated pH for treatment in which case the pH does not exceed 10.)

Page 326: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-14 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WA.5.9.IL. Facilities must not contribute to an exceedance of effluent standards for mercury (35 IAC 304.126).

Verify that the concentration of mercury in any effluent does not exceed 0.0005 mg/L.

(NOTE: Discharges may be exempt if the following conditions are met: - the discharger does not use mercury; or, the discharger uses mercury and this

use cannot be eliminated, or, the discharger uses mercury only in chemical analysis or in laboratory or other equipment and takes reasonable care to avoid contamination of wastewater, and,

- the effluent mercury concentration is less than 0.003 mg/1, and - the discharger is providing the best degree of treatment consistent with

technological feasibility, economic reasonableness and sound engineering judgment, and

- the discharger has an inspection and maintenance program likely to reduce or prevent an increase in the level of mercury discharges.)

(NOTE: Discharges may be exempt if the following conditions are met:

- the discharger is a publicly owned or publicly regulated sewage treatment works

- the discharger does not use mercury, or, the discharger uses mercury only in chemical analysis or in laboratory or other equipment and takes reasonable care to avoid contamination of wastewater

- the effluent mercury concentration is less than 0.003 mg/1, provided, however, that daily averages may exceed 0.006 mg/1 30 percent of the time

- the discharger has enforceable ordinances or contract provisions whereby it limits use of mercury by dischargers and discharge of mercury into its sewage system

- the discharger's limitations on use and discharge of mercury to its sewage system are at least as stringent as in WQ.30.1.IL.

- the discharger has a surveillance program with a reasonable likelihood of determining sources of mercury discharged to the sewage system

- the discharger takes all lawful steps to eliminate known mercury discharges to the sewage system which contribute levels in excess of those allowed by WQ.30.1.IL.

- the discharger reports all known violations of WQ.30.1.IL. to the Agency.)

Page 327: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-15 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WA.10. PERMITS NPDES

WA.10.1.IL. Facilities that discharge contaminants or pollutants into the waters of the state must have a valid NPDES permit (35 IAC 309.102 and 309.104).

Verify that a facility that discharges any contaminant or pollutant into the waters of the state from a point source or into a well has a valid NPDES permit.

(NOTE: An NPDES permit is not required for any discharge into a well that is authorized by an Underground Injection Control (UIC) permit.)

Verify that the facility applies for the reissuance of an NPDES permit 180 days prior to the expiration date of the permit.

WA.10.2.IL. Facilities that construct treatment works, disposal wells, or wastewater sources must have an authorization to construct (35 IAC 309.154).

Verify that the facility does not cause or allow the construction or modification of any treatment works, disposal well, or wastewater source that is required to have an NPDES permit without obtaining an authorization to construct as a condition of the NPDES permit.

Page 328: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-16 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WA.15. STATE PERMITS

WA.15.1.IL. Facilities that operate treatment or pretreatment works, sewers, or wastewater sources that are not covered by a NPDES per-mit must have a valid con-struction permit (35 IAC 309.202).

Verify that the facility does not cause or allow the construction or modification of any new treatment works, sewer or wastewater source without a construction permit issued by the Agency.

(NOTE: Construction permits are not required for the following: - storm sewers that transport only land runoff - any treatment works, sewer or wastewater source that serves a single building

and treats or discharges less than an average of 1500 gal/day of domestic sewage and discharges directly to a publicly owned or publicly regulated sanitary or combined sewer

- other sewers required to secure a permit.)

WA.15.2.IL. Facilities must have operating permits for treatment works, sewers, or wastewater sources not covered by NPDES permits (35 IAC 309.203, 309.204, and 309.203).

Verify that the facility does not cause or allow the use or operation of any treatment works, sewer, or wastewater source for which a construction permit is required (see preceding checklist item) without an operating permit issued by the Agency, except as may be authorized by the construction permit.

Verify that the facility does not cause or allow the use or operation of any treatment works, pretreatment works or wastewater source without an operating permit issued by the Agency.

(NOTE: No operating permit is required under this checklist item for any discharge:

- for which an NPDES permit is required, or - for which a pretreatment permit has been issued by the Agency, or for which

an authorization to discharge has been issued by a POTW with an approved pretreatment program.)

(NOTE: Operating permits are not required for treatment works and wastewater

sources that are designed and intended to serve a single building and eventually treat or discharge less than an average of 1500 gallons per day (5700 1/day) of domestic sewage and which will discharge, if at all, directly to a publicly owned or publicly regulated sanitary or combined sewer.)

(NOTE: Operating permits are not required for those pretreatment works or wastewater sources discharging to a sewer tributary to a treatment works which will not:

- discharge toxic pollutants, or pollutants which may interfere with the treatment process into the receiving treatment works or are subject to regulations promulgated under Section 307 of the Clean Water Act (CWA)

- discharge 15 percent or more of the total hydraulic flow received by the

Page 329: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-17 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

treatment works - discharge 15 percent or more of the total biological loading received by the

treatment works as measured by the 5-day biochemical oxygen demand.)

(NOTE: In cases where the Agency determines that a proposed treatment works, pretreatment works, sewer or wastewater source is sufficiently standard so as to obviate the need for separate construction and operating permits, the Agency may issue a joint construction and operating permit.)

Page 330: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-18 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WA.20. TREATMENT WORKS

WA.20.1.IL. Treatment works and associated facilities must meet specific construction and operating standards (35 IAC 306.102).

Verify that all treatment works and associated facilities are constructed and operated to minimize violations of applicable standards during such contingencies as flooding, adverse weather, power failure, equipment failure, or maintenance, through such measures as multiple units, holding tanks, duplicate power sources, or other measures as appropriate.

Verify that all reasonable measures, including where appropriate the provision of catchment areas, relief vessels, or entrapment dikes, are taken to prevent any spillage of contaminants from causing water pollution.

WA.20.2.IL. Permitted treatment works must be supervised by a certified operator (35 IAC 312.101).

Verify that the facility does not cause or allow the use or operation of any treatment works for which a permit is required unless the operation is under the direct and active field supervision of a person who has been certified by the Agency as being competent to operate the particular type or size of treatment works.

Page 331: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-19 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

DISCHARGES TO A POTW/FOTW WA.30. PRETREATMENT STANDARDS

WA.30.1.IL. Facilities must meet pretreatment standards for mercury (35 IAC 307.1102).

(NOTE: Mercury discharges are allowed only where its use cannot be eliminated or its use is in chemical analysis, laboratory, or other equipment and reasonable care is taken to avoid wastewater contamination.)

Verify that nonexempt discharges into a publicly owned or publicly regulated sewer system do not exceed a mercury concentration of 0.0005 mg/L unless a less stringent limitation applies to the sewer system.

(NOTE: Discharge is to a publicly owned or publicly regulated sewer system are exempt if the system is required to meet a limitation less stringent than the 0.0005 mg/1 mercury concentration in which case the discharge limitation is the same as that applicable to the publicly owned or regulated sewer system to which it discharges.)

(NOTE: Discharges are exempt if all of the following conditions are met: - the discharger does not use mercury; or, the discharger uses mercury and this

use cannot be eliminated, or, the discharger uses mercury only in chemical analysis or in laboratory or other equipment and takes reasonable care to avoid contamination of wastewater

- the discharge mercury concentration is less than 0.003 mg/1 - the discharger is providing the best degree of treatment consistent with

technological feasibility, economic reasonableness and sound engineering judgment

- the discharger has an inspection and maintenance program likely to reduce or to prevent an increase in the level of mercury discharges.)

(NOTE: The discharge of wastes from medicinal or therapeutic use of mercury,

exclusive of laboratory use, are exempt from the limitations of this checklist item if all the following conditions are met:

- the total plant discharge is less than 227 g (1/2 lb) as Hg in any year - this discharge is to a public sewer system - the discharge does not, alone or in conjunction with other sources, cause the

effluent from the sewer system or treatment plant to exceed 0.0005 mg/1 of mercury.)

Verify that the facility does not cause or allow any discharge of mercury to a

publicly owned or publicly regulated sewer system which, alone or in combination with other sources, causes a violation by the sewer treatment plant discharge of the

Page 332: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-20 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

water quality standard for mercury applicable in the receiving stream.

WA.30.2.IL. Facilities must meet pretreatment standards for cyanide (35 IAC 307.1103).

Verify that no waste to any public sewer system contains more than 10 mg/l total cyanide, provided any sample tested does not release more than 2 mg/l of cyanide when tested at a pH of 4.5 and at a temperature of 66 °C (150 °F) for a period of 30 min.

Page 333: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-21 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

SEWAGE SYSTEMS WA.100. MARINE FACILITIES

WA.100.1.IL. The disposal of wastes from watercrafts must meet specific standards (35 IAC 308.102 and 308.103).

Verify that watercraft operated on the waters of the state that are equipped with toilets have one of the following acceptable pollution control devices:

- holding tanks that retain wastes from marine toilets for proper disposal - incinerating devices that reduce to ash all sewage and toilet wastes produced

on the watercraft (ash must not be disposed of in the waters of Illinois) - any other device approved by the IEPA.

Verify that sewage or wastewater accumulated in a holding tank or any other container on a watercraft does not reach the waters of the state except by pump out to an operating sewer works approved or permitted by the Agency.

Verify that no bilge or ballast that fails to meet effluent standards is discharged to the waters of the state.

Page 334: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-22 Wastewater Management

Page 335: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-23 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WA.150. WATERSHED PROTECTION PROGRAMS

Existing Facilities in Setback Zones or Regulated Recharge Areas

(NOTE: These requirements do not apply to any of the following: - facilities covered by a certification of minimal hazard - facilities with an adjusted standard - facilities located on the same site as a facility noncommunity water system

well - facilities located within a recharge area that meet the following additional

conditions: - the boundary of the lateral area of influence of a community water supply

well located within the regulated recharge area does not include the facility - the distance from the community water supply wellhead to the facility

exceeds 2500 ft and the community water supply well was not in existence prior to 1 January 1988.)

Existing Facilities: Surface Impoundments

(NOTE: These requirements do apply to existing surface impoundment units that are located wholly or partially within a setback zone or regulated recharge area and that contain special waste or other waste generated on-site, except that they do not apply to any existing surface impoundment unit that contains solely one or more of the following: hazardous waste, livestock waste, landscape waste, or construction and demolition debris.)

WA.150.1.IL. Existing surface impoundments must meet specific closure standards (35 IAC 615.441 through 615.443).

Determine whether the facility has an existing surface impoundment that contains special waste or other waste generated onsite and is located wholly or partially within a setback zone or regulated recharge area.

Verify that surface impoundment facilities located within a minimum setback zone have completed closure by 10 January 1995.

Verify that if a surface impoundment is located within a designated maximum setback zone, it is not operated after 2 yr of the designation of the maximum setback zone, and is closed within 3 yr.

WA.150.2.IL Existing surface impoundments must meet specific closure standards (35 IAC

Verify that where closure is by removal, the owner removes all waste residues, contaminated containment system components, subsoils, structures and equipment contaminated with waste and leachate.

Page 336: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-24 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

615.202(b), 615.303, and 615.447).

Verify that where closure is by a method other than removal, the owner meets the following closure standards:

- free liquids are eliminated by removing liquid wastes or solidifying the remaining wastes and waste residues

- the remaining wastes are stabilized to a bearing capacity sufficient to support final cover

- the surface impoundment facility has a final cover consisting of at least a 2 ft compacted clay layer with no more than a 1 x 10-7cm/s permeability designed to:

- provide long-term minimization of the migration of liquids through the closed impoundment facility

- function with minimum maintenance - promote drainage and minimize erosion or abrasion of the final cover - accommodate settling and subsidence so that integrity is maintained.

Verify that if some wastes residues or contaminated materials are left in place at final closure, the owner:

- maintains final cover, including repairs to the cap to correct for settling, sub-sidence, erosion or other events

- maintains and monitors the groundwater monitoring system - prevents run-on and runoff from eroding or damaging the final cover.

Verify that the IEPA is notified within 60 days of completion of closure of a surface impoundment facilities

(NOTE: The postclosure care period for existing surface impoundment facilities is 5 yr after closure not including any required corrective actions.)

Existing Facilities: Waste Piles

(NOTE: These requirements apply to existing waste piles that contain special waste or other waste generated onsite and are located wholly or partially within a setback zone or regulated recharge area. Existing waste pile requirements do not apply to facilities that solely contain hazardous waste, livestock waste, landscape waste, and/or construction and demolition debris; or, waste piles that contain sludge from a POTW’s wastewater treatment and the sludge pile is situated on an underdrained pavement.)

WA.150.3.IL. Existing waste piles must meet specific closure standards (35 IAC 615.202 and 615.461 through 615.464).

Verify that waste pile meets closure standards for a landfill unless otherwise allowed by the IEPA.

Verify that for existing waste piles that are not required to meet landfill closure standards:

- waste piles of liquids or materials containing free liquids are not disposed or

Page 337: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-25 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

stored - leachate does not migrate or runoff into adjacent soil, surface water, or

groundwater - the waste pile is under an impermeable membrane or cover that provides

protection from precipitation - the waste pile is protected from surface water run-on - the waste pile is designed and operated to control wind dispersal of waste by

a means other than wetting.

Verify that closure is accomplished by removing and disposing of all wastes and containment system components and, if disposed of in the State of Illinois, the waste and containment system components are disposed of at a permitted disposal site.

(NOTE: The postclosure care period for existing waste piles is 5 yr after closure not including any required corrective actions.)

Existing Facilities: Underground Storage Tanks

(NOTE: These requirements apply to existing underground storage tanks that are located wholly or partially within a setback zone or regulated recharge area and that contain special waste, except for any existing underground storage tank that:

- meets the requirements set forth in 35 Ill. Adm. Code 731 (the underground storage tank regulations in the Storage Tank Management chapter of this manual and the TEAM Guide)

- has interim status or a RCRA permit.)

WA.150.4.IL. Specific existing underground storage tanks holding special waste must meet underground hazardous waste storage tank standards (35 IAC 615.501 and 615.502).

Verify that the underground storage tank meets hazardous waste operating and design standards (see the Storage Tank Management chapter of the TEAM Guide, sections ST.100 through ST.115).

New Facilities In Setback Zones Or Regulated Recharge Areas

(NOTE: The following requirements do not apply to any facility that is covered by a certification of minimal hazard or granted an alternate standard.)

New Facilities: Surface Impoundments

(NOTE: These requirements apply to new surface impoundment facilities that contain special waste or other waste generated onsite and are located wholly or partially within a setback zone or regulated recharge area. They does not apply to new surface impoundment facilities that solely contain hazardous waste, livestock

Page 338: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-26 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

waste, landscape waste, and/or construction and demolition debris.)

WA.150.5.IL. New surface impoundments must meet location standards (35 IAC 616.442).

Verify that surface impoundment facilities are not operated or:

- wholly or partially within a minimum setback zone and is either a new potential primary source or a new potential secondary source

- wholly or partially within a maximum setback zone and is a new potential primary source.

WA.150.6.IL. New surface impoundments must meet inspection and monitoring standards (35 IAC 616.443 and 616.445).

Verify that facilities with surface impoundment facilities meet groundwater monitoring, preventive notification and response, and corrective action standards for new onsite land treatment facilities.

Verify that surface impoundments are inspected weekly and after storms to detect evidence of:

- deterioration, malfunctions, or improper operation of overtopping control systems

- sudden drops in the level of the impoundment’s contents - severe erosion or other signs of deterioration in dikes or other containment

devices - a leaking dike.

Verify that incompatible materials are not placed in the same surface impoundment.

WA.150.7.IL. New surface impoundments removed from service must meet specific standards (35 IAC 616.446(a) through (e)).

Verify that a surface impoundment is removed from service when:

- the level of liquids in the facility suddenly drops and the drop is not caused - the dike leaks.

Verify that surface impoundments removed from service for the above reasons meet the following requirements:

- the flow of additional wastes is shut off or stopped - any surface leakage that has occurred is contained - leaks are stopped - steps are taken to stop or prevent catastrophic failure - if leaks cannot be stopped, the impoundment facility is emptied.

Verify that the IEPA is notified within 10 days of any surface impoundment that is removed from service or any corrective actions taken.

Page 339: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-27 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

Verify that surface impoundments that are removed from service are not restored to service unless the portion of the facility that has failed has been repaired.

Verify that surface impoundments removed from service and not repaired are closed.

WA.150.8.IL. Closure of a new surface impoundment facility must meet specific standards (35 IAC 616.447).

Verify that, when closure is by removal, the owner removes all waste residues, contaminated containment system components, contaminated subsoils, and structures and equipment contaminated with waste and leachate and disposes of them, if in the State of Illinois, at a permitted disposal site.

Verify that when closure is by a method other than removal, the owner meets the following closure standards:

- free liquids are eliminated by removing liquid wastes or solidifying the remaining wastes and waste residues

- the remaining wastes are stabilized to a bearing capacity sufficient to support final cover.

Verify that the final cover meets the following construction standards:

- long-term minimization of the migration of liquids - cover functions with minimum maintenance - promotes drainage and minimizes erosion or abrasion of the final cover - cover accommodates settling and subsidence so that integrity is maintained - a permeability less than or equal to the permeability of any bottom liner

system.

Verify that, if some wastes residues or contaminated materials are left in place at final closure:

- final cover is maintained including repairs to the cap to correct for settling, subsidence, erosion or other events

- the groundwater monitoring system is maintained and monitored - run-on and run-off is prevented from eroding or damaging the final cover.

New Facilities: Open Waste Piles

(NOTE: These requirements apply to new waste piles that contain special waste or other waste generated onsite and are located wholly or partially within a setback zone or regulated recharge area. This does not apply to any new waste pile that solely contain hazardous waste, livestock waste, landscape waste, and/or construction and demolition debris; or, waste piles that contain sludge from a POTW’s wastewater treatment and the sludge pile is situated on an underdrained pavement.)

Page 340: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-28 Wastewater Management

COMPLIANCE CATEGORY: WASTEWATER MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WA.150.9.IL. Onsite waste piles must meet specific operating standards (35 IAC 616.462 through 616.464).

Verify that onsite waste piles are not operated or constructed in the following loca-tions:

- wholly or partially within a minimum setback zone and is either a new potential primary source or a new potential secondary source

- wholly or partially within a maximum setback zone and is a new potential primary source.

Verify that special wastes are not disposed in a new waste pile located within a

regulated recharge area and 2500 ft from a community water supply wellhead unless specifically exempted.

Verify that liquids or materials that contain free liquids are not disposed or stored in the waste pile.

Verify that leachate is not allowed to migrate or runoff into adjacent soil, surface water, or groundwater.

Verify that the waste pile is protected as follows:

- the waste pile is under an impermeable membrane or cover that provides protection from precipitation

- the waste pile is protected from surface water run-on - the waste pile is designed and operated to control wind dispersal of waste by

a means other than wetting.

Verify that facilities with closed waste piles remove and dispose all wastes and containment system components and, if disposed of in the State of Illinois, dispose of them in a permitted disposal site.

Page 341: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

12-29 Wastewater Management

Appendix 12-1

Effluent Concentration Standards (Source: 35 IAC 304.124(a))

Constituent STORET Number

Concentration (mg/L)

Arsenic 01002 0.25 Barium 01007 2.0 Cadmium 01027 0.15 Chromium (hexavalent)* 01032 0.1 Chromium (total) 01034 1.0 Copper 01042 0.5 Cyanide 00720 0.10 Fluoride 00951 15.0 Iron (total) 01045 2.0 Lead 01051 0.2 Manganese 01055 1.0 Nickel 01067 1.0 Oils (hexane soluble or equivalent) 00550 15.0 Phenols 32730 0.3 Silver 01077 0.1 Zinc (total) 01092 1.0 Total Dissolved Solids 00530 15.0

* Discharges of hexavalent chromium are subject to the averaging rules and modified as follows:

- monthly averages do not exceed 0.1 mg/L - daily composites do not exceed 0.3 mg/L - and grab samples do not exceed 1.0 mg/L.

NOTES:

- oils may be analytically separated into polar and nonpolar components and if the separation is done, neither of the components may exceed 15 mg/L.

- unless otherwise indicated, concentrations refer to the total amount of the constituent present in all phases, whether solid, suspended or dissolved, elemental or combined, including all oxidation states. Where constitu-ents are commonly measured as other than total, the word “total” is inserted for clarity.

Page 342: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-1 Water Quality Management

SECTION 13

WATER QUALITY MANAGEMENT

Illinois Supplement, June 2000 This section covers the Illinois requirements for Water Quality Management and is intended to supplement the U.S. TEAM Guide. Refer to the U.S. TEAM Guide and the DOD Component Supplements for Federal, DOD, and service-specific requirements.

Relation to Federal Regulations

Part 611 of Title 35 of the Illinois Administrative Code (35 IAC 611) satisfies the requirement of Section 17.5 of the Environmental Protection Act (Act) [Chapter 415 Illinois Consolidated Statutes (ILCS) 5/17.5] that the Board adopt regulations which are identical in substance with Federal regulations promulgated by the United States Environmental Protection agency (USEPA) pursuant to Sections 1412(b), 1414(c), 1417(a) and 1445(a) of the Safe Drinking Water Act (SDWA) (42 U.S.C. 300f et seq.). This Section establishes primary drinking water requirements (NPDWRs) pursuant to the SDWA, and also includes additional, related State requirements which are consistent with and more stringent than the USEPA regulations. The latter provisions are specifically marked as “additional State requirements.” They apply only to community water systems (CWSs).

Definitions

• Agency - the Illinois Environmental Protection Agency (35 IAC 601.105). • Board - the Illinois Pollution Control Board (35 IAC 601.105). • Boil Order - a notice to boil all drinking and culinary water for at least five minutes before use, issued by the

proper authorities to the consumers of a public water supply affected, whenever the water being supplied may have become microbacteriologically contaminated (35 IAC 601.105) [Revised May 1998].

• CT or CTcalc - is the product of residual disinfectant concentration (RDC or C) in mg/L determined before or at

the first customer, and the corresponding disinfectant contact time (T) in minutes. If a water system applies disinfectants at more than one point prior to the first customer, it will determine the CT of each disinfectant sequence before or at the first customer to determine the total percent inactivation or total inactivation ratio. In determining the total inactivation ratio, the supplier must determine the RDC of each disinfection sequence and corresponding contact time before any subsequent disinfection application points (see CT99.9) (35 IAC 611.101).

• CT99.9 - is the CT value required for 99.9 percent (3-log) inactivation of Giardia lamblia cysts (35 IAC

611.101). • Calumet River System - the Calumet River, the Grand Calumet River, the Little Calumet River downstream from

its confluence with the Grand Calumet, the Calumet-Sag Channel and the Calumet Harbor Basin (35 IAC 301.245).

• Certified Laboratory - any laboratory approved by the Agency, Illinois Department of Nuclear Safety, or the

Illinois Department of Public Health for the specific parameters to be examined, as set out in rule adopted pursuant to the Illinois Administrative Procedure Act (5 ILCS 100) (35 IAC 601.105) [Revised May 1998].

Page 343: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-2 Water Quality Management

• Chemical Analysis - analysis for any inorganic or organic substance, with the exception of radiological or microbiological analysis (35 IAC 601.105).

• Chicago River System - the Chicago River and its branches, the North Shore Channel, and the Chicago Sanitary

and Ship Canal (35 IAC 301.250). • Chlorine Demand - the difference between the amount of chlorine applied to a given water and the amount of

total available chlorine remaining at the end of the contact period. All test conditions (contact time, pH, and temperature) shall be given in expressing the chlorine demand in a given water (35 IAC 651.102).

• Coagulation - a process using coagulant chemicals and mixing by which colloidal and suspended materials are

destabilized and agglomerated into flocs (35 IAC 611.101). • Community Water System (CWS) - a public water system (PWS) which serves at least 15 service connections

used by year-round residents or regularly serves at least 25 year-round residents (35 IAC 611.101). • Confined Geologic Formations - geologic water bearing formations protected against the entrance of

contamination by other geologic formations (35 IAC 601.105). • Confluent Growth - a continuous bacterial growth covering the entire filtration area of a membrane, or a portion

thereof, in which bacterial colonies are not discrete (35 IAC 611.101). • Contaminant - any physical, chemical, biological, or radiological substance or matter in water (35 IAC

611.101). • Conventional Filtration Treatment - a series of processes including coagulation, flocculation, sedimentation,

and filtration resulting in substantial particulate removal (35 IAC 611.101). • Cross-Connection - any physical connection or arrangement between two otherwise separate piping systems,

one of which contains potable water and the other contains water of unknown or questionable safety or stream, gases, or chemicals, if there may be a flow from one system to the other (35 IAC 651.102) [Revised June 2000].

• Diatomaceous Earth Filtration - a process resulting in substantial particulate removal in which (35 IAC

611.101): 1. a precoat cake of diatomaceous earth filler media is deposited on a support membrane (septum) 2. while the water is filtered by passing through the cake on the septum, additional filter media known as

body feed is continuously added to the feed water to maintain the permeability of the filter cake. • Direct Cross-Connection - a cross-connection formed when a water system is physically joined to a source of

unknown or unsafe substance (35 IAC 651.102). • Direct Filtration - a series of processes including coagulation and filtration but excluding sedimentation

resulting in substantial particulate removal (35 IAC 611.101). • Disinfectant - any oxidant, including but not limited to chlorine, chlorine dioxide, chloramines and ozone added

to water in any part of the treatment or distribution process, that is intended to kill or inactivate pathogenic microorganisms (35 IAC 611.101).

• Disinfection - a process which inactivates pathogenic organisms in water by chemical oxidants or equivalent

agents (35 IAC 611.101). • Domestic or Other Nondistribution System Plumbing Problem - a coliform contamination problem in a PWS

with more than one service connection that is limited to site specific service connection from which the coliform-positive sample was taken (35 IAC 611.101).

Page 344: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-3 Water Quality Management

• Dose Equivalent - the product of the absorbed dose from ionizing radiation and such factors as account for

differences in biological effectiveness due to the type of radiation and its distribution in the body as specified by the International Commission on Radiological Units and Measurements (35 IAC 601.105).

• Filtration - a process for removing particulate matter from water by passage through porous media (35 IAC

611.101). • Flocculation - a process to enhance agglomeration or collection of smaller floc particles into larger more easily

settleable particles (35 IAC 611.101). • Gross Alpha Particle Activity - the total radioactivity due to alpha particle emission as inferred from

measurements on a dry sample (35 IAC 601.105). • Gross Beta Particle Activity - the total radioactivity due to beta particle emission as inferred from measurements

on a dry sample (35 IAC 601.105). • Groundwater - underground water which occurs within the saturated zone and geologic materials where the fluid

pressure in the pore space is equal to or greater than atmospheric pressure (35 IAC 601.105). • Groundwater Under the Direct Influence of Surface Water - the Agency determines if the groundwater is under

the influence of groundwater. The following are used to determine that a groundwater source is under the influence of surface water (35 IAC 611.101):

1. physical characteristics of the source 2. well construction characteristics 3. source water quality records 4. rapid shifts in water characteristics.

• Halogen - one of the chemical elements chlorine, bromine or iodine (35 IAC 601.105). • Indirect Cross-Connection - a cross-connection formed when an unknown substance can be forced, drawn by

vacuum or otherwise introduced into a safe water system (35 IAC 651.102). • Interconnection - a physical connection between two or more community water supply systems (35 IAC

651.102). • Interstate Waters - all waters that cross or form part of the border between Illinois and other states (35 IAC

301.295). • Intrastate Waters - all the waters of Illinois that are not interstate waters (35 IAC 301.300). • Lake Michigan Basin - consist of the following (35 IAC 303.443) [Added May 1998]:

1. The Open Waters of Lake Michigan, that is, all of the waters within Lake Michigan in Illinois jurisdiction lakeward from a line drawn across the mouth of tributaries to Lake Michigan, but not including waters enclosed by constructed breakwaters;

2. Lake Michigan harbors and waters within Illinois jurisdiction within breakwaters, and waters tributary to Lake Michigan including streams, sloughs and other watercourses not named elsewhere in this Part; and

3. The Chicago River, the North Shore Channel, and the Calumet River are not part of the Lake Michigan Basin.

• Legionella - a genus of bacteria, some species of which have caused a type of pneumonia called Legionnaires

Disease (35 IAC 611.101).

Page 345: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-4 Water Quality Management

• Manmade Beta Particle and Photon Emitters - all radionuclides emitting beta particles and/or photons listed in Maximum Permissible Body Burdens and maximum Permissible Concentration of Radionuclides in Air or Water for Occupational Exposure, National Bureau of Standards (NBS) Handbook 69, except the daughter products of thorium-232, uranium-235, and uranium-238 (35 IAC 601.105).

• Maximum Residence Time Concentration (MRTC) - the concentration of total trihalomethanes found in a water

sample taken at a point of maximum residence time in the public water supply distribution system (35 IAC 601.105).

• Maximum Total Trihalomethane Potential (MTP) - the maximum concentration of total trihalomethanes

produced in a given water containing a disinfectant residual after 7 days at a temperature of 25 oC or above (35 IAC 601.105).

• Mixing Zone - a portion of the waters of the state identified as a region within which mixing is allowed (35 IAC

302.100). • Near the First Service Connection - at one of the 20 percent of all service connections in the entire system that

are nearest the PWS treatment facility, as measured by water transport time within the distribution system (35 IAC 611.101).

• Noncommunity Water System (non-CWS) - a PWS which is not a CWS (35 IAC 611.101). • Nontransient Noncommunity Water System (NTNCWS) - a PWS that is not a CWS and that regularly serves at

least 25 of the same persons over 6 mo per year (35 IAC 611.101). • NPDWR - national primary drinking water regulation (35 IAC 611.101). • NTU - nephelometric turbidity unit (35 IAC 611.101). • Official Custodian - any officer of an organization which is the owner or operator of a public water supply, and

who has direct administrative responsibility for the supply (35 IAC 601.105). • P-A Coliform Test - presence-absence coliform test (35 IAC 611.101). • Performance Evaluation Sample - a reference sample provided to a laboratory for the purpose of demonstrating

that the laboratory can successfully analyze the sample within one unit of performance specified by the Agency, or for non-CWS, Public Health. The true value of the concentration of the reference material is unknown to the laboratory at the time of the analysis (35 IAC 611.101).

• Persistent Contamination - exists when analysis for total coliform is positive in one or more samples of a routine

sample set, and when three or more subsequent check samples indicate the presence of contamination (35 IAC 601.105).

• Person - an individual, corporation, company, association, partnership, state, unit of local government or

Federal agency (35 IAC 611.101). • PicoCurie (pCi) - the quantity of radioactive material producing 2.22 nuclear transformations per minute (35

IAC 601.105). • Point of Disinfectant Application - is the point at which the disinfectant is applied and downstream of which

water is not subject to recontamination by surface water runoff (35 IAC 611.101).

Page 346: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-5 Water Quality Management

• Point-of-Entry Treatment Device - is a treatment device applied to the drinking water entering a house or building for the purpose of reducing contaminants in the water distributed throughout the house or building (35 IAC 611.101).

• Point of Maximum Residence Time - that part of the active portion of the distribution system remote from the

treatment plant where the water has been in the distribution system for the longest period of time (35 IAC 601.105).

• Primary Contact - any recreational or other water use in which there is prolonged and intimate contact with the

water involving considerable risk of ingesting water in quantities sufficient to pose a significant health hazard, such as swimming and water skiing (35 IAC 301.355).

• Public and Food Processing Water Supply - any water use in which water is withdrawn from surface waters of

the state for human consumption or for processing of food products intended for human consumption (35 IAC 301.360).

• Public Water System (PWS) - a system for the provision to the public of piped water for human consumption. If

such system has at least 16 service connections or regularly serves an average of at least 25 individuals daily at least 60 days out of the year. A PWS is either a CWS or a non-CWS. This term includes (35 IAC 611.101):

1. any collection, treatment, storage, and distribution facilities under control of the operator of such system and used primarily in connection with such system

2. any collection or pretreatment storage facilities not under such control which are used primarily in connection with such system.

• Recurring Contamination - exists when analysis of total coliform is positive in one or more samples of a routine

sample set, if this occurs four or more times in a calendar year (35 IAC 601.105). • Rem - the unit of dose equivalent form ionizing radiation to the total body or any internal organ or organ system.

A “millirem (mrem)” is 1/1000 or a rem (35 IAC 601.105). • Residual Disinfectant Concentration (RDC or C in CT calculations) - the concentration of disinfectant measured

mg/L in a representative sample of water. Where only one RDC is measured, T is tile time in nurtures that it takes for water to move front the point of disinfection application to a point before or at where RDC is measured. Where more than one RDC is measured, T is (35 IAC 611.101):

1. for the first measurement of RDC, the time in minutes that it takes for water to move from the first or only point of disinfectant application to a point before or at the point where the fist RDC is measured and

2. for subsequent measurements of RDC, the time in minutes that it takes for water to move from the previous RDC measurement point to the RDC measurement point for which the particular T is being calculated. T in pipelines must be calculated based on “plug flow” by dividing the inlet volume of the pipe by tile maximum hourly flow rate through that pipe. T within mixing basins and storage reservoirs must be determined by tracer studies or equivalent demonstration.

• Safe Drinking Water Act (SDWA) - the Public Health Service Act, as amended by the Safe Drinking Water Act,

PL 93-523, 42 USC 300f et seq (35 IAC 611.101). • Sanitary Survey - an onsite review of the water source, facilities, equipment, operation, and maintenance of a

PWS for the purpose of evaluating the adequacy of such source, facilities, equipment, operation, and maintenance for producing and distributing safe drinking water (35 IAC 611.101).

• Secondary Contact - any recreational or other water use in which contact with the water is either incidental or

accidental and the probability of ingesting appreciable quantities of water is minimal, such as fishing, commercial and recreational boating, and any limited contact incident to shoreline activity (35 IAC 301.380).

• Sedimentation - a process for removal of solids before filtration by gravity or separation (35 IAC 611.101).

Page 347: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-6 Water Quality Management

• Sell Water - to deliver or provide potable water, obtained from a public water supply subject to these

regulations, to the consumer, who is then individually or specifically billed for water service, or where any monetary assessment is levied or required and specifically used for water service. Water supply facilities owned or operated by political subdivisions, homeowners associations, and not-for-profit associations, as well as privately owned utilities regulated by the Illinois Commerce Commission, are considered to sell water whether or not a charge is specifically made for water (35 IAC 601.105) [Added May 1998].

• Service Connection - is the opening, including all fittings and appurtenances, at the water main through which

water is supplied to the user (35 IAC 601.105). • Slow Sand Filtration - a treatment process involving passage of raw water through a bed of sand at low velocity

(generally less than 235 gal/ft2/day resulting in substantial particulate removal by physical and biological mechanisms.

• Standard Sample - the aliquot of finished drinking water that is examined for the presence of coliform bacteria

(35 IAC 611.101). • STORET - the national storage and retrieval water quality data system of the USEPA (35 IAC 301.405). • Surface Water - all water which is open to the atmosphere and subject to surface runoff (35 IAC 611.101). • Surface Water - all tributary streams and drainage basins, including natural lakes and artificial reservoirs, which

may affect a specific water supply above the point of water supply intake (35 IAC 601.105). • Surface Water Supply Source - any surface water used as a water source for a public water supply (35 IAC

601.105). • Supply - means a public water supply (35 IAC 601.105). • Synthetic Organic Compounds (SOC) - any synthetic organic compound including but not limited to the

following: o-Dichlorobenzene, cis-1,2-Dichloroethylene, trans-1,2-Dichloroethylene, 1,2-Dichloropropane, Ethylbenzene, Monochlorobenzene, Styrene, Tetrachloroethylene, Toluene, and Xylene (35 IAC 611.101).

• System With a Single Service Connection - a water system which supplies drinking water to customers via a

single service line (35 IAC 611.101). • Too Numerous To Count (TNTC) - that the total number of bacterial colonies exceeds 200 on a 47 mm diameter

membrane filter used for coliform bacteria detection (35 IAC 611.101). • Total Trihalomethanes (TTHM) - the sum of the concentration in milligrams per liter of the trihalomethane

compounds trichloromethane (chloroform), dibromochloromethane, bromodichloromethane and tribromomethane (bromoform), rounded to two significant figures (35 IAC 601.105).

• Trihalomethanes (THM) - one of the family of organic compounds, named as derivatives of methane in which

three of the four hydrogen atoms in methane are each substituted by a halogen atom in the molecular structure. The THMs are (35 IAC 601.105):

1. trichloromethane (chloroform) 2. dibromochloromethane 3. bromodichloromethane 4. tribromomethane (bromoform).

• USEPA - the U.S. Environmental Protection Agency (35 IAC 611.101).

Page 348: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-7 Water Quality Management

• Virus - a virus of fecal origin which is infectious to humans by waterborne transmission (35 IAC 611.101). • VOC - volatile organic chemical (35 IAC 611.101). • Water Main - any pipe for the purpose of distributing potable water which serves or is accessible to more than

one property, dwelling, or rental unit, and is exterior to buildings (35 IAC 601.105). • Waters - all accumulations of water, surface and underground, natural, and artificial, public and private, or parts

thereof, that are wholly or partially within, flow through, or border upon the State of Illinois, except that sewers and treatment works are not included except as specially mentioned; provided, that nothing herein contained shall authorize the use of natural or otherwise protected waters as sewers or treatment works except that in-stream aeration under Illinois Environmental Protection Agency (IEPA) permit is allowable (35 IAC 301.440).

• Waterborne Disease Outbreak - the significant occurrence of acute infectious illness, epidemiologically

associated with the ingestion of water from a public water system that is deficient in treatment, as determined by the Agency (35 IAC 611.101).

• Wellhead Protection Program - the wellhead protection program for the State of Illinois, approved by USEPA

(35 IAC 611.101).

Page 349: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-8 Water Quality Management

Page 350: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-9 Water Quality Management

AIR EMISSIONS MANAGEMENT GUIDANCE FOR ILLINOIS CHECKLIST USERS

REFER TO CHECKLIST ITEMS: Missing Checklist Items WQ.2.1.IL. Permits/Notifications/Exemptions WQ.5.1.IL. Operators WQ.6.1.IL. Operations WQ.8.1.IL. and WQ.8.2.IL. Management/Administrative WQ.9.1.IL. Public Water Systems

General WQ.10.1.IL. and WQ.10.2.IL. Fluoridation WQ.10.3.IL. through WQ.10.5.IL.

Community Water Systems Standards WQ.35.1.IL. through WQ.35.6.IL. Monitoring/Sampling WQ.40.1.IL. Notification and Reporting Requirements WQ.45.1.IL. through WQ.45.3.IL.

Nontransient, Noncommunity Water Systems General WQ.76.1.IL.

Water Quality Standards Groundwater Quality WQ.115.1.IL. through WQ.115.4.IL. Surface Water Quality WQ.115.5.IL. through WQ.115.13.IL.

GUIDANCE FOR APPENDIX USERS

REFER TO APPENDIX NUMBERS: REFER TO APPENDIX TITLES:

13-1

Groundwater Quality Standards for Class I: Potable Resource Groundwater

13-2 Criteria for Preventive Notification for Class I: Potable Resource Groundwater

13-3 Groundwater Quality Standards for Class III: General Resource Groundwater

13-4 Acute and Chronic Numeric Standards for Waters with No Specific Designation

13-5 Maximum Levels for Specific Chemical Constituents 13-6 Maximum Temperature Levels 13-7 Maximum Ammonia Nitrogen Levels 13-8 Public and Food Processing Water Supply Standards 13-9 Secondary Contact and Indigenous Aquatic Life Standards

13-10 Lake Michigan Water Quality Standards 13-11 Lake Michigan Maximum Temperature Levels

Page 351: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-10 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WQ.2. MISSING CHECKLIST ITEMS

WQ.2.1.IL. Facilities are required to comply with all applicable state regulatory requirements not contained in this checklist (a finding under this checklist item will have the citation of the applied regulation as a basis of finding).

Determine whether any new regulations have been issued since the finalization of the manual.

Determine whether the facility has activities or facilities that are regulated but not addressed in the checklists.

Verify that the facility is in compliance with all applicable and newly issued regulations.

Page 352: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-11 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

WQ.5. PERMITS/ NOTIFICATIONS/ EXEMPTIONS

WQ.5.1.IL. New public water supplies or new additions to an existing water supply must be permitted (35 IAC 602.101 and 602.102) [Moved in structural reorganization of WQ.5 October 1999].

Verify that facilities constructing a new public water systems or adding to an existing systems have a permit to construct.

(NOTE: Public water supply installation, change, or addition does not include routine maintenance, service pipe connections, hydrants and valves, or replacement of equipment, pipes, and appurtenances.)

Verify that facilities operating a new public water systems or operating additions to an existing system have a permit to operate.

Page 353: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-12 Water Quality Management

Page 354: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-13 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

WQ.6. OPERATORS

WQ.6.1.IL. Public water systems must have certified operators (35 IAC 603.103) [Moved in structural reorganization of WQ.5 October 1999].

Verify that public water systems have a certified operator.

Verify that the public water system notifies the Agency of the certified operator in responsible charge on forms provided by the Agency

(NOTE: Both the treatment and distribution facilities of each supply must have responsible personnel indicated. One properly certified operator may supervise both the treatment and distribution facilities of the supply.)

Page 355: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-14 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000 [Reorganized October 1999]

WQ.8. OPERATIONS

WQ.8.1.IL. Public water supplies must not apply algicide without a permit (35 IAC 602.103) [Moved in structural reorganization of WQ.5 October 1999].

Verify that public water supply systems do not apply algicide to any stream, reservoir, lake, pond, or other body of water used as a public water supply source without an algicide permit issued by the Agency

(NOTE: Copper sulphate is the only algicide which may be used in public water supplies.)

(NOTE: This permit is only valid for public water supply sources.)

WQ.8.2.IL. Facilities must not apply aquatic pesticides without a permit (35 IAC 652.601) [Moved in structural reorganization of WQ.5 October 1999].

Verify that facilities do not apply aquatic pesticides to waters of the state where the application of the pesticides will have an effect on public or food processing water supplies without a permit.

(NOTE: A permit is required when aquatic pesticide is applied within 20 mi upstream of a public or food processing water supply.)

Page 356: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-15 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WQ.9. MANAGEMENT/ ADMINISTRATIVE

WQ.9.1.IL. New public water supplies must demonstrate adequate system capacity (35 IAC 651.102 and 652.701) [Added June 2000].

Verify that new public water supply systems demonstrate the technical and managerial capacity to operate the system to the Agency.

(NOTE: A “new public water supply" (new PWS) means, beginning after 1 October 1999, all new community water supplies and new non-transient non-community water supplies and those water supplies that expand their infrastructure to serve or intend to serve at least 25 persons at least 60 days per year. Any water system not currently a PWS that adds persons so that the total served is 25 persons or more without constructing additional infrastructure will become a PWS, but will not be required to demonstrate capacity unless the PWS is on restricted status.)

Page 357: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-16 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

PUBLIC WATER SYSTEMS

WQ.10. GENERAL

WQ.10.1.IL. Public water supplies must issue boil orders if contamination occurs during an emergency (35 IAC 607.103).

Verify that whenever contamination is determined to persist in a public water supply, as demonstrated by microbiological analysis results, the owners or official custodians of the supply notify all consumers to boil all water used for drinking or culinary purposes until microbiological samples demonstrate that the water is safe for domestic use, or until appropriate corrective action approved by the Agency is taken.

Verify that, if water pressure falls below 20 psi on any portion of the distribution system due to an emergency, a boil order is issued to the consumers affected unless:

- there is a historical record of adequate chlorine residual and approved turbidity levels in the general area affected covering at least 12 monthly readings

- samples for microbiological examination are taken in the affected area immediately and approximately 12 h later

- tests for residual chlorine and turbidity taken at not more than hourly intervals in the affected area for several hours do not vary significantly from the historical record (if a significant decrease in chlorine residual or increase in turbidity occurs, a boil order must be issued.)

Verify that, if the safety of a supply is endangered for any reason, including but

not limited to spillage of hazardous substances:

- the Agency is notified immediately by the water system, and the supply officials shall take appropriate action to protect the supply

- the owner, official custodian or his authorized representative notifies all consumers of appropriate action to protect themselves against any waterborne hazards.

(NOTE: If the owner or official custodian of the supply fails to take such action

on his own or at the recommendation of the Agency, the Agency will notify directly the consumers affected.)

WQ.10.2.IL. Systems with public water supplies must meet requirements for cross

Verify that no physical connection between the potable portion of a supply and any other water supply not of equal or better microbiological and chemical quality as determined by the Agency.

Page 358: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-17 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

connections (35 IAC 607.104).

as determined by the Agency.

Verify that no arrangement or connection is made to allow an unsafe substance to enter a supply.

Fluoridation

WQ.10.3.IL. Systems with fluoridation equipment must obtain an operating permit, provide instructions to operating personnel, and notify the state (35 IAC 653.702).

Verify that operating personnel are provided instructions for the use of the fluoridation equipment.

Verify that the facility obtains an operating permit prior to initiating operation of the fluoridation equipment, and notifies the Illinois Department of Public Health when the fluoridation is started.

WQ.10.4.IL. Systems with fluoridation equipment must meet sampling requirements (35 IAC 653.703).

Verify that samples are submitted to the IEPA laboratory.

(NOTE: Sample containers will be furnished by the IEPA.)

WQ.10.5.IL. Systems with fluoridation equipment must meet recordkeeping requirements (35 IAC 653.704).

Verify that the system submits a copy of the daily operating report record signed by the certified operator to the IEPA each month showing:

- amount of water pumped - fluoride chemical used - amount of fluoride chemical fed - gallons of dilution water used - calculated fluoride dosage - fluoride ion test results.

Verify that systems with more than one source of water with separate fluoridation used maintains an individual set of records for each facility.

Verify that a copy of the daily operating report record is maintained by the operator of the community water supply.

Page 359: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-18 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

COMMUNITY WATER SYSTEMS

WQ.35. STANDARDS

WQ.35.1.IL. Community water system (CWS) suppliers in Illinois must meet addi-tional State requirements for MCLs for total trihalomethane (TTHM) and for specific organic chemicals (35 IAC 611.310(a) and (c)) [Revised June 2000].

Verify that CWSs do not exceed the following MCLs for the organic chemicals listed:

- Aldrin, 0.001 mg/L - DDT, 0.05 mg/L - Dieldrin, 0.001 mg/L - Heptachlor, 0.0001mg/L - Heptachlor epoxide, 0.0001mg/L - 2,4-D, 0.01 mg/L

(NOTE: Originally derived from 40 CFR 141.12(a) (1994), USEPA removed the last entry in this subsection and marked it reserved at 57 Fed. Reg. 31838 (July 17, 1992). USEPA added another listing of organic MCLs at 40 CFR 141.61 (1994). Heptachlor, Heptachlor epoxide, and 2,4-D are listed here and in the larger listing of organic MCLs. The heptachlor, heptachlor epoxide, and 2,4-D MCLs in this checklist item are Illinois limitations that are more stringent than the federal requirements. However, detection of these contaminants or violation of their Federal MCLs imposes more stringent monitoring, reporting, and notice requirements.)

Verify that CWSs do not exceed the MCL for TTHM of 0.10 mg/L.

(NOTE: The MCL of 0.10 mg/L for TTHM applies to a community water system subject to filtration and disinfection requirements that serves 10,000 or more persons, until 31 December 2001. The MCL of 0.10 mg/L for TTHM applies to community water systems that use only groundwater and serve 10,000 or more persons, until 31 December 2003.)

(NOTE: Derived in part from 40 CFR 141.12(c) (1994). This is an additional State requirement to the extent it applies to all CWS supplies, not just CWSs that add a disinfectant at any part of treatment and which provide water to 10,000 or more individuals.)

WQ.35.2.IL. CWSs must have required analyses performed at either an Agency lab or a certified laboratory

Verify that the CWS supplier has required analyses performed either at an Agency laboratory, or a certified laboratory.

(NOTE: The Agency may require that some or all of the required samples be

Page 360: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-19 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

(35 IAC 611.490). submitted to its laboratories.)

WQ.35.3.IL. CWS suppliers must have adequate laboratory equipment (35 IAC 611.491).

Verify that each CWS supplier has adequate laboratory equipment and capability to perform operational tests (except bacteriological) appropriate to the parameters to be tested and the type of treatment employed.

Verify that such equipment is in good operating condition, and the operator on duty is familiar with the procedure for performing the tests.

(NOTE: Nothing in this Subpart shall be construed to prevent a CWS supplier from running control laboratory tests in an uncertified laboratory. These results are not to be included in the required monitoring results.)

WQ.35.4.IL. CWSs must meet finished water quality standards when using surface water (35 IAC 654.101).

Verify that surface water is approved as a community water supply only if treatment to produce a finished water is provided.

Verify that sampling is performed to determine treatment requirements.

Verify that a representative sample is collected at least once a month over 12 consecutive periods to determine raw water quality.

Verify that more frequent sampling is done to obtain a true representation of raw surface water quality.

(NOTE: Raw water characteristics are determined after heavy rainfall and runoff, low stream flow, and at other times when unusual factors pertaining to physical and chemical quality, treatability, tastes, and odors exist.)

Verify that a 12-mo running geometric mean is used to calculate raw water bacteriological quality.

Verify that treatment includes coagulation, clarification, rapid sand filtration or its equivalent, and continuous post-chlorination for all surface waters.

(NOTE: Auxiliary treatment shall be provided for waters containing coliform bacteria exceeding 5000 per 100 mm in more than 20 percent of the samples examined during any 1 mo. Examples of auxiliary treatment are presedimentation, prechlorination, and storage of raw water for 30 days or more.)

WQ.35.5.IL. CWSs must adopt an active cross-con-nection control program (35 IAC 653.801).

Verify that CWSs have an active cross-connection program that includes a cross-connection control survey of the distribution system at least every two years by the official custodian or an authorized delegate.

Page 361: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-20 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

IAC 653.801). (NOTE: The purpose of this survey is to compile and update an inventory of devices; the survey must consist of a pencil and paper collection of information, conducted by telephone, mail or personal visit to the manager or owner of a specific property. This survey is not intended to include an actual visual inspection of piping or plumbing systems.)

Verify that the cross-connection program includes:

- an ordinance, tariff, or required condition for service (whichever is applicable), which includes a plumbing code at least as stringent as the Illinois State Plumbing Code, 77 Ill. Adm. Code 890

- a record system which maintains data on inspections, re-inspections, repairs, alterations, and tests

- only cross-connection control devices approved by the Research Foundation for Cross-Connection Control of the University of Southern California, American Water Works Association American Society of Sanitary Engineering, or American National Standards Institute or certified by the National Sanitation Foundation to be in compliance with applicable industry specifications

- installation of approved devices made only as specified by the above maintained as recommended by the manufacturer of the device (the manufacturer’s maintenance manual must be available onsite).

Page 362: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-21 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

COMMUNITY WATER SYSTEMS

WQ.40. MONITORING/ SAMPLING

WQ.40.1.IL. CWSs in Illinois must monitor for State MCLs at specific frequencies (35 IAC 611.592).

(NOTE: This checklist item applies to old MCLs that are marked as “additional State requirements” at Section 611.300 [see WQ.35.1.IL. and WQ.35.2.IL. above], and for which no specific monitoring, reporting or public notice requirements are specified elsewhere.)

Verify that analyses for all CWS suppliers utilizing surface water sources are repeated at yearly intervals.

Verify that analyses for all CWS suppliers utilizing only groundwater sources are repeated at 3 yr intervals.

Page 363: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-22 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

COMMUNITY WATER SYSTEMS

WQ.45. NOTIFICATION AND REPORTING REQUIREMENTS

WQ.45.1.IL. CWS must report violations of State MCLs according to specific requirements (35 IAC 611.591).

(NOTE: This section applies to old MCLs that are marked as “additional State requirements” at Section 611.300 [see WQ.35.1.IL. and WQ.35.2.IL. above], and for which no specific monitoring, reporting or public notice requirements are specified elsewhere.)

Verify that, if the result of analysis indicates that the level of any contaminant exceeds the State MCL, the CWS supplier:

- reports to the Agency within 7 days, and initiates three additional analyses at the same sampling point within 1 month

- notifies the Agency and gives public notice, when the average of four analyses, rounded to the same number of significant figures as the old MCL for the contaminant in question, exceeds the old MCL

- monitors, after public notification, at a frequency designated by the Agency, and continues monitoring until the old MCL has not been exceeded in two consecutive samples, or until a monitoring schedule as a condition of a variance or enforcement action becomes effective.

WQ.45.2.IL. CWS suppliers must submit monthly operating reports (35 IAC 611.831).

Verify that, within 30 days following the last day of the month, each CWS supplier submits a monthly operating report to the Agency on forms provided or approved by the Agency.

WQ.45.3.IL. CWS suppliers exempt from disinfection requirements must submit monthly reports on educational activities (35 IAC 611.833).

Verify that each CWS supplier exempted from the disinfection requirement reports monthly to the Agency its activity to educate and inform its customers about preventing contamination into the distribution system.

Page 364: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-23 Water Quality Management

Page 365: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-24 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

NONTRANSIENT, NONCOMMUNITY WATER SYSTEMS WQ.76. STANDARDS

WQ.76.1.IL. Nontransient, noncommunity water systems must have certified operators (77 IAC 900.45(a) and (b)) [Added June 2000].

Verify that all nontransient, noncommunity public water systems are directly supervised and operated by personnel who:

- are currently the operator in responsible charge of the nontransient, noncommunity public water system and whose identity has been submitted to the Department by 1 January 2000, or

- have been certified by the Department, or - have been certified as a public water supply Operator by the Illinois

Environmental Protection Agency. Verify that all operators are certified by 1 January 2003.

Verify that all nontransient, noncommunity public water systems provide the Department with the name, address and phone numbers of the certified individual operating the supply.

Verify that the Department is notified in writing within 30 days after a different person becomes responsible for Operation of the supply.

Page 366: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-25 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WQ.90. DRINKING WATER WELL

(NOTE: This section provides minimum standards for water wells which are not otherwise subject to regulation under the Environmental Protection Act, Title IV, Public Water Supplies (Ill. Rev. Stat. 1991, ch. 111 1/2, pars. 1014-1019 [415 ILCS 5/Title IV]. No water well may be constructed or modified contrary to the provisions of this section (77 IAC 920.20).)

WQ.90.1.IL. Water wells must be constructed only by licensed contractors (77 IAC 920.30(a) and (b)) [Added May 1998].

Verify that water wells are constructed only by persons having a valid license under the Illinois Water Well and Pump Installation Contractor's License Act.

Verify that 30 days after a water well has been constructed or deepened, the contractor submits a report of construction to the Department on forms prescribed and furnished by the Department.

WQ.90.2.IL. Abandonment of water wells must meet specific requirements (77 IAC 920.120(a)(1) and (2) and (e)(1)) [Added May 1998].

Verify that a water well is sealed within 30 days after it is abandoned and when the well is no longer used to supply water, or is in such a state of disrepair that the well or boring has the potential for transmitting contaminants into an aquifer or otherwise threatens the public health or safety.

Verify that water wells are sealed by a licensed water well driller.

Verify that the Department, approved local health department, or approved unit of local government is notified by telephone or in writing at least 48 hr prior to the commencement of any work to seal a water well.

Page 367: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-26 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WQ.100. MISCELLANEOUS WELLS

WQ.100.1.IL. Abandonment of boring or monitoring wells must meet specific requirements (77 IAC 920.120(a)(1) and (e)(1)) [Added May 1998].

Verify that a boring or monitoring well is sealed within 30 days after it is abandoned or is in such a state of disrepair that the well or boring has the potential for transmitting contaminants into an aquifer or otherwise threatens the public health or safety.

Verify that the Department, approved local health department, or approved unit of local government is notified by telephone or in writing at least 48 hr prior to the commencement of any work to seal a monitoring well.

Page 368: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-27 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WQ.115. WATER QUALITY STANDARDS

Groundwater Quality (NOTE: Groundwater is not required to meet the general use standards and public and food processing water supply standards of 35 IAC 302. Subparts B and C. Also, the requirements of this section do not apply to underground waters contained in man-made subsurface drains, tunnels, reservoirs, storm sewers, tiles, or sewers.)

WQ.115.1.IL. Facilities must not contaminate or contribute to the degradation of groundwater (35 IAC 620.301 and 620.405).

Verify that the facility does not cause, threaten, or allow the release of any contaminant to groundwater so as to cause a groundwater quality standard to be exceeded.

Verify that the facility does not cause, threaten or allow the release of any contaminant to a resource groundwater such that:

- treatment or additional treatment is necessary to continue an existing use or to assure a potential use of such groundwater

- an existing or potential use of such groundwater is precluded.

(NOTE: Nothing in this regulation prevents the establishment of a groundwater management zone or a cumulative impact area within a permitted site.)

(NOTE: Nothing in this Regulation limits underground injection pursuant to a permit issued by the Agency or issued by the Department of Mines and Minerals.)

(NOTE: Nothing in this regulation limits the Board from promulgating nondegra-dation provisions applicable to particular types of facilities or activities which impact upon groundwater, including but not limited to landfills.)

WQ.115.2.IL. Facilities that exceed groundwater quality standards must submit preventive notification (35 IAC 620.302 and 620.305).

(NOTE: Preventive notification and preventive response applies to Class I and III groundwater which is monitored by:

- an owner or operator of a regulated entity for which groundwater quality monitoring must be performed pursuant to State or Federal law or regulation

- an owner or operator of a public water supply well who conducts groundwater quality monitoring

- a state agency which is authorized to conduct, or is the recipient of, groundwater quality monitoring data

- an owner or operator of a facility that conducts groundwater quality monitoring pursuant to State or federal judicial or administrative order.)

Page 369: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-28 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

(NOTE: If a contaminant exceeds a standard set forth in Appendix 13-1, the

appropriate remedy is corrective action and the preventive notification requirements do not apply.)

Verify that the facility provides preventive notification whenever a contaminant:

- listed Appendix 13-2 is detected (except due to natural causes) in Class I or Class III groundwater

- denoted as a carcinogen under Appendix 13-1 is detected in Class I groundwater.

(NOTE: When a preventive notification is required for groundwater which is

monitored by a regulated entity for the subject contaminant, the owner or operator of the site shall confirm the detection by resampling the monitoring well. This resampling shall be made within 30 days of the date on which the first sample analyses are received. The owner or operator shall provide a preventive notification to the appropriate regulatory agency of the results of the resampling analysis within 30 days of the date on which the sample analyses are received, but no latter than 90 days after the results of the first samples were received.)

(NOTE: When a preventive notification of a confirmed detection has been provided by an owner or operator, additional detections of the same contaminant do not require further notice, provided that the groundwater quality conditions are substantially unchanged or that preventive response is underway for such contaminant.)

WQ.115.3.IL. Facilities must not contribute to an exceedance of groundwater quality standards for Class III special resource groundwater (35 IAC 620.430).

Verify that concentrations of inorganic and organic chemical constituents do not exceed the standards set forth in section Appendix 13-1, except for those chemical constituents for which the Board has adopted an adjusted standard.

WQ.115.4.IL. Facilities must not contribute to an exceedance of groundwater quality standards for Class IV groundwater (35 IAC 620.440).

Verify that facilities do not cause or contribute to an exceedance of existing concentrations of constituents in groundwater.

(NOTE: For groundwater within a zone of attenuation, the standards specified in Appendix 13-3 must not be exceeded, except for concentrations of contaminants within leachate released from a permitted unit.)

(NOTE: For groundwater within a previously mined area, the standards set forth in Appendix 13-3 must not be exceeded, except for concentrations of TDS, chloride, iron, manganese, sulfates, or pH. For concentrations of TDS, chloride, iron,

Page 370: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-29 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

manganese, sulfates, or pH, the standards are the existing concentrations.)

Surface Water Quality (NOTE: The general use water quality standards apply to waters of the state for which there are no specific designations. See definition of waters.)

WQ.115.5.IL. Waters of the state must meet general use water quality standards (35 IAC 302.203 through 302.207).

Verify that the waters of the state are free from sludge or bottom deposits, floating debris, visible oil, odor, plant or algal growth, color or turbidity other than of natural origin.

Verify that the waters of the state have a pH between 6.5 and 9.0 except for natural causes.

Verify that the waters of the state have a phosphorus level as P that does not exceed 0.05 mg/L in any reservoir or lake with a surface area of 8.1 ha (20 acres) or more, or in any stream at the point where it enters any such reservoir or lake.

(NOTE: Reservoirs or lakes do not include low level pools constructed in free-flowing streams or any body of water that is an integral part of an operation that includes the application of sludge on land. Point source discharges that comply with effluent standards or a permit are in compliance with this protocol.)

Verify that the waters of the state have a dissolved oxygen level that is not less than 6.0 mg/L during at least 16 h of any 24-h period, nor less than 5.0 mg/L at any time.

Verify that the waters of the state have a gross beta concentration that does not exceed 100 pCi/L.

Verify that the waters of the state do not exceed the following levels of radioactivity:

- radium-226, 1 pCi/L - strontium-90, 2 pCi/L.

WQ.115.6.IL. Waters of the state must meet general use water quality standards for chemical constituents (35 IAC 302.208).

Verify that the waters of the state do not exceed the acute standard (AS) listed in Appendix 13-4 at any time except for those waters that are approved zones of initial dilution.

Verify that the waters of the state do not exceed the chronic standard (CS) listed in Appendix 13-4 except for waters designated as mixing zones.

(NOTE: Compliance with the chronic standard is determined by the arithmetic average of at least four consecutive samples collected over any period of at least 4

Page 371: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-30 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

days.)

Verify that the waters of the state do not exceed the concentrations of the chemical constituents in Appendix 13-5 except in waters where mixing is allowed.

WQ.115.7.IL. Facilities with waters of the state must meet general use water quality standards for fecal coliforms (35 IAC 302.209).

Verify that the during the months of May through October, a minimum of five samples are taken from the waters of the state over not more than a 30-day period and analyzed for fecal coliform content.

Verify that during the months of May through October the fecal coliform of the waters of the state do not exceed the following levels:

- a geometric mean of 200/100 mL - in protected waters, not more than 10 percent of the samples during any 30-

day period exceed 400/100 mL.

(NOTE: Protected waters are defined as waters that, due to natural characteristics, aesthetic value or environmental significance are deserving of protection from pathogenic organisms and either presently supports or has the physical characteristics to support primary contact; or flows through or is adjacent to parks or residential areas.)

Verify that waters of the state outside of mixing zones are free from any substances or combination of substances in concentrations toxic or harmful to human health, or to animal, plant, or aquatic life.

WQ.115.8.IL. Waters of the state must meet general use water quality standards for temperature (35 IAC 302.211(b) through (e)).

Verify that there are no abnormal temperature changes in the waters of the state that may adversely affect aquatic life unless caused by natural conditions.

Verify that the maximum temperature rise above natural temperatures of the waters of the state does not exceed 2.8 °C (5 °F).

Verify that the water temperature at representative locations in the main river (see definitions) does not exceed the maximum limits listed in Appendix 13-6 as follows:

- during more than 1 percent of the hours in a 12-mo period ending with any month

- by more than 1.7 °C (3 °F).

WQ.115.9.IL. Waters of the state must meet general use water quality standards for

Verify that levels of ammonia nitrogen as N in the waters of the state do not exceed 15 mg/L.

Page 372: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-31 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

ammonia nitrogen and un-ionized ammonia (35 IAC 302.212).

Verify that waters with concentrations of ammonia nitrogen less than 15 mg/L and greater than or equal to 1.5 mg/L, have levels of un-ionized ammonia as N that does not exceed 0.04 mg/L.

Verify that the levels of ammonia nitrogen concentrations do not exceed the levels specified in Appendix 13-7 for specific combinations of pH and temperature.

WQ.115.10.IL. Public and food processing water supplies must meet specific water quality standards (35 IAC 302.301 and 302.304 through 302.306).

Determine whether the facility withdraws waters for treatment and distribution as a potable supply.

Verify that at the point where the waters are withdrawn for treatment and distribution the following standards are met:

- the waters do not exceed the concentration levels in Appendix 13-8 - other contaminants are not present in concentrations hazardous to human

health - the geometric mean of the fecal coliform concentration based on a minimum

five samples taken over not more than a 30-day period does not exceed 2000/ 100 mL.

WQ.115.11.IL. Waters designated for secondary contact and indigenous aquatic life must meet specific water quality standards (35 IAC 302.401 through 302.410).

Determine whether the facility has waters designated as secondary contact and indigenous aquatic life.

Verify that the waters are free from unnatural sludge or bottom deposits, floating debris, visible oil, odor, unnatural plant or algal growth, or unnatural color or turbidity.

Verify that the waters have a pH between 6.0 and 9.0, except due to natural causes.

Verify that the dissolved oxygen levels of the waters in the Calumet Sag Channel are not less than 3.0 mg/L at any time and all other waters are not less than 4.0 mg/L at any time.

Verify that the chemical constituents of the waters do not exceed the concentrations listed in Appendix 13-9.

Verify that the temperature of the waters do not exceed 34 °C (93 °F) more than 5 percent of the time or 37.8 °C (100 °F) at any time.

Verify that any substance toxic to aquatic life listed in Appendix 10-6 does not exceed one half of the 96-h median tolerance limit (96-h TLm) for native fish or essential fish food organisms.

Page 373: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-32 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

WQ.115.12.IL. Lake Michigan waters must meet specific water quality standards (35 IAC 302.501 through 302.506) [Revised May 1998].

Determine whether the facility contains waters designated as Lake Michigan waters.

Verify that the dissolved oxygen levels of the waters:

- are not less than 90 percent of saturation, except due to natural causes, in the Open Waters of Lake Michigan (see definitions)

- are not less than 6.0 mg/L during at least 16 hours of any 24 hour period, nor less than 5.0 mg/L at any time, in the other waters of the Lake Michigan Basin.

Verify that the pH of the waters:

- is within the range of 7.0 to 9.0, except for natural causes, in the Open Waters of Lake Michigan

- is within the range of 6.5 to 9.0, except for natural causes, in the other waters of the Lake Michigan Basin.

Verify that the concentrations of the chemical constituents listed in Appendix 13-

10 are not exceeded.

Verify that fecal coliform levels based on a minimum of five samples taken over not more than a 30-day period do not exceed the following:

- a geometric mean of 20 per 100 ml in the Open Waters of Lake Michigan as - a geometric mean of 200 per 100 ml in the remaining waters of the Lake

Michigan Basin (or that more than 10 percent of the samples during any 30 day period exceed 400 per 100 ml.)

WQ.115.13.IL. Sources of heated effluent into Lake Michigan waters must meet specific standards (35 IAC 302.507 through 302.509) [Revised May 1998].

Verify that sources of heated effluent that were under construction or in existence on 1 January 1971, or that discharge less than a daily average of 29 megawatts (0.1 billion Btu/hr) but not under construction or operating on 1 January 1971, meet the following temperature standards outside the mixing zone:

- there are no abnormal temperature changes that affect aquatic life - normal daily and seasonal temperature fluctuations that existed before the

addition of heat are maintained - the maximum temperature rise at any time above the natural temperatures

does not exceed 1.7 °C (3 °F) - water temperatures do not exceed the maximum listed in Appendix 13-11.

(NOTE: The area outside the mixing zone is defined here as a circle no greater than a radius of 305 m (1000 ft) or an equal fixed area of simple form.)

Verify that sources of heated effluents that were not in operation or under construction as of 1 January 1971 do not discharge more than a daily average of

Page 374: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-33 Water Quality Management

COMPLIANCE CATEGORY: WATER QUALITY MANAGEMENT

Illinois Supplement

REGULATORY REQUIREMENTS:

REVIEWER CHECKS: June 2000

29 MW (0.1 billion Btu/h).

Verify that sources of heated effluent that were under construction but not in operation on 1 January 1971, or that discharge less than a daily average of 29 megawatts (0.1 billion Btu/hr) but not under construction or operating on 1 January 1971, meet the following restrictions:

- neither the bottom, the shore, the hypolimnion, nor the thermocline is affected by any heated effluent

- no heated effluent affects spawning grounds or fish migration routes - no discharge exceeds ambient temperatures by more than 11 °C (20 °F) - heated effluent from more than one source do not interact - all reasonable steps are taken to reduce the number of organisms drawn into

or against the intakes.

Page 375: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-34 Water Quality Management

Appendix 13-1

Groundwater Quality Standards for Class I: Potable Resource Groundwater

(Source: 35 IAC 620.410) A. Except due to natural causes or as provided elsewhere in these regulations, concentrations of the following chemical constituents must not be exceeded in Class I groundwater:

Constituent Units Standard Arsenic mg/L 0.05 Barium mg/L 2 Beryllium mg/L 0.004 Boron mg/L 2 Cadmium mg/L 0.005 Chloride mg/L 200 Chromium mg/L 0.1 Cobalt mg/L 1 Copper mg/L 0.65 Cyanide mg/L 0.2 Fluoride mg/L 4.0 Iron mg/L 5 Lead mg/L 0.0075 Manganese mg/L 0.15 Mercury mg/L 0.002 Nickel mg/L 0.1 Nitrate as N mg/L 10 Radium-226 pCi/L 20 Radium-228 pCi/L 20 Selenium mg/L 0.05 Silver mg/L 0.05 Sulfate mg/L 400 Thallium mg/L 0.002 Total Dissolved Solids (TDS) mg/L 1200 Zinc mg/L 5

B. Except due to natural causes, or as provided below, or as provided elsewhere in these regulations, concentrations of the following organic chemical constituents must not be exceeded in Class I groundwater:

Constituent Standard (mg/L) Alachlor* 0.002 Aldicarb 0.003 Atrazine 0.003 Benzene* 0.005 Benzo(a)pyrene* 0.0002 Carbofuran 0.04

Page 376: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-35 Water Quality Management

Constituent Standard (mg/L) Carbon Tetrachloride* 0.005 Chlordane* 0.002 Dalapon 0.2 Dichloromethane* 0.005 Di(2-ethylhexyl)phthalate* 0.006 Dinoseb 0.007 Endothall 0.1 Endrin 0.0002 Ethylene Dibromide* 0.00005 Endrin 0.002 Heptachlor* 0.0004 Heptachlor Epoxide* 0.0002 Hexachlorocyclopentadiene 0.05 Lindane (Gamma-Hexachloro cyclohexane) 0.0002 2,4-D 0.07 ortho-Dichlorobenzene 0.6 para-Dichlorobenzene 0.075 1,2-Dibromo-3-Chloropropane* 0.0002 1,2-Dichloroethane* 0.005 1,1-Dichloroethylene 0.007 cis-1,2-Dichloroethylene 0.07 trans-1,2-Dichloroethylene 0.1 1,2-Dichloropropane* 0.005 Ethylbenzene 0.7 Methoxychlor 0.04 Monochlorobenzene 0.1 Pentachlorophenol* 0.001 Phenols 0.1 Picloram 0.5 Polychlorinated Biphenyls (PCB's) (as decachloro-bipehnyl)* 0.005 Simazine 0.004 Styrene 0.1 2,4,5-TP (silvex) 0.05 Tetrachloroethylene* 0.005 Toluene 1 Toxaphene* 0.003 1,1,1-Trichloroethane 0.2 1,1,2-Trichloroethane 0.005 1,2,4-Trichlorobenzene 0.07 Trichloroethylene* 0.005 Vinyl Chloride* 0.002 Xylenes 10

* Denotes a carcinogen.

C. Concentrations of the following chemical constituents of gasoline, diesel fuel, or heating fuel must not be exceeded in Class I groundwater:

Page 377: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-36 Water Quality Management

Constituent Standard (mg/L) Benzene* 0.005 BETX 11.705

* Denotes a carcinogen.

D. pH, Except due to natural causes, a pH range of 6.5 - 9.0 units must not be exceeded in Class I groundwater.

E. Beta Particle and Photon Radioactivity

1) Except due to natural causes, the average annual concentration of beta particle and photon radioactivity

from man-made radionuclides shall not exceed a dose equivalent to the total body organ greater than 4 mrem/year in Class I groundwater. If two or more radionuclides are present the sum of their dose equiva-lent to the total body, or to any internal organ shall not exceed 4 mrem/year in Class I groundwater except due to natural causes.

2) Except for the radionuclides listed below, the concentration of man-made radionuclides causing 4 mrem

total body or organ dose equivalent must be calculated on the basis of a 2 liter per day drinking water intake using the 168-hour data in accordance with the procedure set forth in NCRP Report Number 22, incorporated by reference at in Section 620.125(a).

3) Except due to natural causes, the average annual concentration assumed to produce a total body or organ

dose of 4 mrem/year of the following chemical constituents shall not be exceeded in Class I groundwater:

Critical Constituent Standard Organ (pCi/1)

Tritium Total body 20,000 Strontium-90 Bone marrow 8

Page 378: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-37 Water Quality Management

Appendix 13-2

Criteria for Preventive Notification for Class I: Potable Resource Groundwater

(Source: 35 IAC 620.310(a)(3)(A))

If a preventive notification is provided by the owner or operator of a regulated entity and the applicable standard in Subpart D has not been exceeded, the appropriate regulatory agency shall determine if any of the following occurs for Class I: Potable Resource Groundwater:

Constituent Criterion (mg/L) para-Dichlorobenzene 0.005 ortho-Dichlorobenzene 0.01 Ethylbenzene 0.03 Phenols 0.001 Styrene 0.01 Toluene 0.04 Xylenes 0.02

a. A statistically significant increase occurs above background (as determined pursuant to other regulatory procedures (e.g., 35 Ill. Adm. Code 616, 724, 725 or 811)) for arsenic, beryllium, cadmium, chromium, cyanide, lead or mercury or thallium (except due to natural causes); or for aldicarb, atrazine, carbofuran, dalapon, dinoseb, endrin, endothall, hexachlorocyclopentadiene, lindane (gamma-hexachlor cyclohexane), 2,4-D,1,1-dichloroethylene, cis-1,2-dichloroethylene, trans-1,2-dichloroethylene, methoxychlor, monochlorobenzene, picloram, simazine, 2,4,5-TP (Silvex) and 1,2,4-trichlorobenzene, 1,1,2-trichloroet-hane, and 1,1,1-trichloroethane.

b. For a chemical constituent of gasoline, diesel fuel, or heating fuel, the constituent exceeds the following:

Constituent Criterion (mg/L)

BETX 0.095

c. For pH, a statistically significant change occurs from background.

Page 379: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-38 Water Quality Management

Appendix 13-3

Groundwater Quality Standards for Class II: General Resource Groundwater

(Source: 35 IAC 620.420)

A. Except due to natural causes or as provided elsewhere in these regulations, or below in this Appendix, concentrations of the following chemical constituents must not be exceeded in Class II groundwater:

Constituent Standard (mg/L) Antimony 0.024 Arsenic 0.2 Barium 2 Beryllium 0.5 Cadmium 0.05 Chromium 1 Cobalt 1 Cyanide 0.6 Fluoride 4.0 Lead 0.1 Mercury 0.01 Nitrate as N 100 Thallium 0.02

B. Except as provided elsewhere in these regulations, or below in this Appendix, concentrations of the following chemical constituents must not be exceeded in Class II groundwater:

Constituent Standard (mg/L Boron 2.0 Chloride 200 Copper 0.65 Iron 5 Manganese 10 Nickel 2 Selenium 0.05 Total Dissolved Solids (TDS) 1,200 Sulfate 400 Zinc 10

C. The standard for any inorganic chemical constituent listed in the immediately preceding table, for barium, or for pH, does not apply to groundwater within fill material or within the upper 10 f t of parent material under such fill material on a site not within the rural property class for which:

1. Prior to the effective date of this Part, surficial characteristics have been altered by the placement of such fill material so as to impact the concentration of the parameters listed in C., and any on-site groundwater monitoring of such parameters is available for review by the Agency.

Page 380: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-39 Water Quality Management

2. On the effective date of this Part, surficial characteristics are in the process of being altered by the placement of such fill material, which proceeds in reasonably continuous manner to completion, so as to impact the concentration of the parameters listed in C., and any on-site groundwater monitoring of such parameters is available for review by the Agency.

(NOTE: For purposes of C., the term “fill material” means clean earthen materials, slag, ash, clean demolition debris, or other similar materials.) D. Except due to natural causes or as provided elsewhere in these regulations, or below in this Appendix, concentrations of the following organic chemical constituents must not be exceeded in Class II groundwater:

Constituent Standard (mg/L) Alachlor* 0.010 Aldicarb 0.015 Atrazine 0.015 Benzene* 0.025 Benzo(a)pyrene* 0.002 Carbofuran 0.2 Carbon Tetrachloride* 0.025 Chlordane* 0.01 Dalapon 2.0 Dichloromethane* 0.05 Dichloromethane 0.05 Di(2-ethylhexyl)phthalate* 0.06 Dinoseb 0.07 Endothall 0.1 Endrin 0.01 Ethylene Dibromide* 0.0005 Heptachlor* 0.002 Heptachlor Epoxide* 0.001 Hexachlorocyclopentadiene 0.5 Lindane (Gamma-Hexachlorocyclo hexane)

0.001

2,4-D 0.35 ortho-Dichlorobenzene 1.5 para-Dichlorobenzene 0.375 1,2-Dibromo-3-Chloropropane*

0.002

1,2-Dichloroethane* 0.025 1,1-Dichloroethylene 0.035 cis-1,2-Dichloroethylene 0.2 trans-1,2-Dichloroethylene 0.5 1,2-Dichloropropane* 0.025 Ethylbenzene 1.0 Methoxychlor 0.2 Monochlorobenzene 0.5 Pentachlorophenol* 0.005 Phenols 0.1 Picloram 5.0 Polychlorinated Biphenyls (PCB's) (as decachloro-biphenyl)*

0.0025

Page 381: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-40 Water Quality Management

Constituent Standard (mg/L) Simazine 0.04 Styrene 0.5 2,4,5-TP 0.25 Tetrachloroethylene* 0.025 Toluene 2.5 Toxaphene* 0.015 1,1,1-Trichloroethane 1.0 1,2,4-Trichlorobenzene 0.7 1,1,2-Trichloroethane 0.05 Trichloroethylene* 0.025 Vinyl Chloride* 0.01 Xylenes 10

* Denotes a carcinogen.

E. The standards for pesticide chemical constituents listed in D. above do not apply to groundwater within 10 feet of the land surface, provided that the concentrations of such constituents result from the application of pesticides in a manner consistent with the requirements of the Federal Insecticide, Fungicide and Rodenticide Act (7 U.S.C. 136 et seq.) and the Illinois Pesticide Act (Ill. Rev. Stat. 1991, ch. 5, pars. 801 et seq.) [415 ILCS 60].

F. Concentrations of the following organic chemical constituents of gasoline, diesel fuel, or heating fuel must not be exceeded in Class II groundwater:

Constituent Standard (mg/L) Benzene* 0.025 BETX 13.525

* Denotes a carcinogen. G. Except due to natural causes, a pH range of 6.5 - 9.0 units must not be exceeded in class II groundwater that is within 5 ft of the land surface.

Page 382: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-41 Water Quality Management

Appendix 13-4

Acute and Chronic Numeric Standards for Waters With No Specific Designation (Source: 35 IAC 302.208(d))

Constituent

STORET Number

AS

(µg/L)

CS

(µg/L)

Arsenic (total) 01002 360 190 Cadmium (total) 01027 exp [A + B ln(H)] but not to exceed 50 µg/L

where A = -2.918 and B = 1.128 exp [A + B ln (H)] where A = -3.490 and

B = 0.7852 Chromium (total hexavalent)

01032

16

11 Chromium (total trivalent) 01033 exp [A + B ln (H)] where A = 3.688 and B =

0.8190 exp [A + B ln (H)] where A = 1.561 and

B = 0.8190 Copper (total) 01042 exp [A + B ln (H)] where A = -1.464

and B = 0.9422 exp [A + B ln (H)] where A = -1.465 and

B = 0.8545 Cyanide 00718 22 5.2 Lead (total) 01051 exp [A + B ln(H)] but not to exceed 100

µg/L where A = -1.460 and B = 1.273

--

Mercury 71900 0.5 -- TRC 50060 19 11

Notes: µg/L = microgram per liter. exp [x] = base of natural logarithms raised to the x-power ln (H) = natural logarithm of Hardness (STORET 00900).

Page 383: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-42 Water Quality Management

Appendix 13-5

Maximum Levels for Specific Chemical Constituents (Source: 35 IAC 302.208(e))

Constituent

STORET Number

Standard

Barium (total) 01007 5.0 mg/L Boron (total) 01022 1.0 mg/L Chloride (total) 00940 500 mg/L Fluoride 00951 1.4 mg/L Iron (dissolved) 01046 1.0 mg/L Manganese (total) 01055 1.0 mg/L Nickel (total) 01067 1.0 mg/L Phenols 32730 0.1 mg/L Selenium (total) 01147 1.0 mg/L Silver (total) 01077 5.0 µg/L Sulfate 00945 500 mg/L Total Dissolved Solids 70300 1000 mg/L Zinc (total) 01092 1.0 mg/L

Page 384: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-43 Water Quality Management

Appendix 13-6

Maximum Temperature Levels

(Source: 35 IAC 302.211(e))

Month Temperature °C (°F) January 16 (60) February 16 (60) March 16 (60) April 32 (90) May 32 (90) June 32 (90) July 32 (90) August 32 (90) September 32 (90) October 32 (90) November 32 (90) December 16 (60)

Page 385: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-44 Water Quality Management

Appendix 13-7

Maximum Ammonia Nitrogen Levels (Source: 35 IAC 302.212(e))

Temperature °C (°F) pH

6.0 6.5 7.0 7.5 8.0 8.5 9.0 5 (41) 15 15 15 9.6 3.1 1.5 1.5 10 (50) 15 15 15 6.5 2.1 1.5 1.5 15 (59) 15 15 13.9 4.4 1.5 1.5 1.5 20 (68) 15 15 9.6 3.1 1.5 1.5 1.5 25 (77) 15 15 6.7 2.1 1.5 1.5 1.5 30 (86) 15 14.9 4.7 1.5 1.5 1.5 1.5 35 (95) 15 10.7 3.4 1.5 1.5 1.5 1.5

Page 386: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-45 Water Quality Management

Appendix 13-8

Public and Food Processing Water Supply Standards

(Source: 35 IAC 302.208(e))

Constituent STORET Number

Concentration (mg/L)

Inorganics Arsenic (total) 01002 0.05 Barium (total) 01007 1.0 Cadmium (total) 01027 0.010 Chloride 00940 250 Chromium 01034 0.05 Iron (dissolved) 01046 0.3 Manganese (total) 01055 0.15 Nitrate-Nitrogen 00620 10.0 Oil (hexane-solubles or equivalent)

00550, 00556 or 00560

0.1

Phenols 32730 0.01 Selenium (total) 01147 0.001 Sulfates 00945 250 Total Dissolved Solids 70300 500 Organics Aldrin 39330 0.001 Chlordane 39350 0.003 DDT 39370 0.05 Dieldrin 39380 0.001 Endrin 39390 0.0002 Heptachlor 39410 0.0001 Heptachlor Epoxide 39420 0.0001 Lindane 39782 0.004 Methoxychlor 39480 0.1 Toxaphene 39400 0.005 Parathion 39540 0.1 2,4-Dichlorophenoxy-acetic acid (2,4-D) 39730 0.1 2-(2,4,5-Trichlorophenoxy)- propi onic acid(2,4,5-TP or Silvex)

39760 0.01

Page 387: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-46 Water Quality Management

Appendix 13-9

Secondary Contact and Indigenous Aquatic Life Standards (Source: 35 IAC 302.407)

Constituent STORET Number

Concentration (mg/L)

Ammonia Un-ionized (as N)* 00619 0.1 Arsenic (total) 01002 1.0 Barium (total) 01007 5.0 Cadmium (total) 01027 0.15 Chromium (total hexavalent) 01032 0.3 Chromium (total trivalent) 01033 1.0 Copper (total) 01042 1.0 Cyanide (total) 00720 0.10 Fluoride (total) 00951 15.0 Iron (total 01045 2.0 Iron (dissolved) 01046 0.5 Lead (total) 01051 0.1 Manganese (total) 01055 1.0 Mercury (total) 71900 0.0005 Nickel (total) 01067 1.0 Oil, fats and grease 00550, 00556

or 00560 15.0**

Phenols 32730 0.3 Selenium (total) 01147 1.0 Silver 01077 1.1 Zinc (total) 01092 1.0 Total Dissolved Solids 70300 1500

*The concentration of un-ionized ammonia is computed according to the following equation: U = N/[0.94412 (1+10x) + 0.0559] where X = 0.09018 + [2729.92/(T + 273.16)]] - pH U = Concentration of un-ionized ammonia as N in mg/L N = Concentration of ammonia nitrogen as N in mg/L T = Temperature in degrees Celsius. ** Oil is analytically separated into polar and nonpolar components if the total concentration exceeds 15 mg/L. Neither the polar materials nor the nonpolar materials can exceed 15 mg/L individually.

Page 388: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-47 Water Quality Management

Appendix 13-10

Lake Michigan Water Quality Standards (Source: 35 IAC 302.504) [Revised May 1998]

The following concentrations of chemical constituents must not be exceeded, except as provided in Sections 302.102 and 302.530:

(a) The following standards must be met in all waters of the Lake Michigan Basin. Acute aquatic life standards (AS) must not be exceeded at any time except for those waters for which the Agency has approved a zone of initial dilution (ZID) pursuant to Sections 302.102 and 302.530. Chronic aquatic life standards (CS) and human health standards (HHS) must not be exceeded outside of waters in which mixing is allowed pursuant to Sections 302.102 and 302.530 by the arithmetic average of at least four consecutive samples collected over a period of at least four days. The samples used to demonstrate compliance with the CS or HHS must be collected in a manner that assures an average representation of the sampling period.

STORET Constituent Number Unit AS CS HHS Arsenic 22680 ug/L 340 148 NA (Trivalent, dissolved) Cadmium 01025 ug/L exp[A exp[A NA (dissolved) + Bln(H)] + Bln(H)] A = -3.6867 A = -2.715 B = 1.128 B = 0.7852 Chromium 01032 ug/L 16 11 NA (Hexavalent, total) Chromium 80357 ug/L exp[A exp[A NA (Trivalent, dissolved) + Bln(H)] + Bln(H)] A = 3.7256 A = 0.6848 B = 0.819 B = 0.819 Copper 01040 ug/L exp[A exp[A NA (dissolved) + Bln(H)] + Bln(H)] A = -1.700 A = -1.702 B = 0.9422 B = 0.8545 Cyanide 00718 ug/L 22 5.2 NA (Weak acid dissociable)

Lead 01049 ug/L exp[A exp[A NA (dissolved) + Bln(H)] + Bln(H)] A = -1.055 A = -4.003 B = 1.273 B = 1.273 Nickel 01065 ug/L exp[A exp[A NA (dissolved) + Bln(H)] + Bln(H)] A = 2.255 A = 0.0584 B = 0.846 B = 0.846 Selenium 01145 ug/L NA 5.0 NA (dissolved) TRC 50060 ug/L 19 11 NA Zinc 01090 ug/L exp[A exp[A NA (dissolved) + Bln(H)] + Bln(H)] A = 0.884 A = 0.884 B = 0.8473 B = 0.8473

Page 389: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-48 Water Quality Management

STORET Constituent Number Unit AS CS HHS Benzene 34030 ug/L NA NA 310 Chlorobenzene 34031 mg/L NA NA 3.2 2,4-Dimethylphenol 34606 mg/L NA NA 8.7 2,4-Dinitrophenol 03756 mg/L NA NA 2.8 Endrin 39390 ug/L 0.086 0.036 NA Hexachloroethane 34396 ug/L NA NA 6.7 Methylene chloride 34423 mg/L NA NA 2.6 Parathion 39540 ug/L 0.065 0.013 NA Pentachlorophenol 03761 ug/L expB([pH] expB([pH] NA + A) + A) A = -4.869 A = -5.134 B = 1.005 B = 1.005 Toluene 78131 mg/L NA NA 51.0 Trichloroethylene 39180 ug/L NA NA 370

Where: NA = Not Applied Exp[x] = base of natural logarithms raised to the x-power ln(H) = natural logarithm of Hardness (STORET 00900)

(b) The following water quality standards must not be exceeded at any time in any waters of the Lake Michigan Basin, unless a different standard is specified under subsection (c) of this Section (see below):

Constituent STORET Number Unit Water Quality Standard Barium (total) 01007 mg/L 5.0 Boron (total) 01022 mg/L 1.0 Chloride (total) 00940 mg/L 500 Fluoride 00951 mg/L 1.4 Iron (dissolved) 01046 mg/L 1.0 Manganese (total) 01055 mg/L 1.0 Phenols 32730 mg/L 0.1 Sulfate 00945 mg/L 500 Total Dissolved Solids 70300 mg/L 1000

c) In addition to the standards specified in subsections (a) and (b) of this Section, the following standards must not be exceeded at any time in the Open Waters of Lake Michigan:

Constituent STORET Number Unit Water Quality

Standard Arsenic (total) 01002 ug/L 500 Barium (total) 01007 mg/L 1.0 Chloride 00940 mg/L 12.0 Iron (dissolved) 01046 mg/L 0.30 Lead (total) 01051 ug/L 50.0 Manganese (total) 01055 mg/L 0.15

Page 390: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-49 Water Quality Management

Constituent STORET Number Unit Water Quality Standard

Nitrate-Nitrogen 00620 mg/L 10.0 Phosphorus 00665 ug/L 7.0 Selenium (total) 01147 ug/L 10.0 Sulfate 00945 mg/L 24.0 Total Dissolved Solids 70300 mg/L 180.0 Oil (hexane solubles or equivalent)

00550, 00556, or 00560

mg/L 0.10

Phenols 32730 ug/L 1.0

d) In addition to the standards specified in subsections (a), (b), and (c) of this Section, the following human health standards (HHS) must not be exceeded in the Open Waters of Lake Michigan by the arithmetic average of at least four consecutive samples collected over a period of at least four days. The samples used to demonstrate compliance with the HHS must be collected in a manner that assures an average representation of the sampling period:

Constituent STORET Number Unit Water Quality Standard Benzene 34030 ug/L 12.0 Chlorobenzene 34301 ug/L 470.0 2,4-Dimethylphenol 34606 ug/L 450.0 2,4-Dinitrophenol 03757 ug/L 55.0 Hexachloroethane (Total) 34396 ug/L 5.30 Lindane 39782 ug/L 0.47 Methylenechloride 34423 ug/L 47.0 Toluene 78131 mg/L 5.60 Trichloroethylene 39180 ug/L 29.0

e) For following bioaccumulative chemicals of concern (BCCs), acute aquatic life standards (AS) must not be exceeded at any time in any waters of the Lake Michigan Basin and chronic aquatic life standards (CS), human health standards (HHS), and wildlife standards (WS) must not be exceeded in any waters of the Lake Michigan Basin by the arithmetic average of at least four consecutive samples collected over a period of at least four days subject to the limitations of Sections 302.520 and 302.530. The samples used to demonstrate compliance with the HHS and WS must be collected in a manner that assures an average representation of the sampling period:

Constituent STORET Number Unit AS CS HHS WS Mercury (total) 71900 ng/L 1,700 910 3.1 1.3 Chlordane 39350 ng/L NA NA 0.25 NA DDT and metabolites 39370 pg/L NA NA 150 11.0 Dieldrin 39380 ng/L 240 56 0.0065 NA Hexachlorobenzene 39700 ng/L NA NA 0.45 NA Lindane 39782 ug/L 0.95 NA 0.5 NA PCBs (class) 79819 pg/L NA NA 26 120 2,3,7,8-TCDD 03556 fg/L NA NA 8.6 3.1 Toxaphene 39400 pg/L NA NA 68 NA

Page 391: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-50 Water Quality Management

Where: mg/L = milligrams per liter (10-3 grams per liter) ug/L = micrograms per liter (10-6 grams per liter) ng/L = nanograms per liter (10-9 grams per liter) pg/L = picograms per liter (10-12 grams per liter) fg/L = femtograms per liter (10-15 grams per liter) NA = Not Applied

Page 392: The Environmental Assessment and Management (TEAM) …The Environmental Assessment and Management (TEAM) Guide Illinois Supplement Revised June 2000 Environmental assessments help

13-51 Water Quality Management

Appendix 13-11

Lake Michigan Maximum Temperature Levels

(Source: 35 IAC 302.507(a)(3))

Month Temperature °C (°F) January 7 (45) February 7 (45) March 7 (45) April 13 (55) May 16 (60) June 21 (70) July 27 (80) August 27 (80) September 27 (80) October 18 (65) November 16 (60) December 10 (50)