  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 1 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    Door Controller Operating Manual

  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 2 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    Contents

    1. Specification --------------------------------------------- 3 2. System Diagram --------------------------------------------- 3 3. External Connectors ------------------------------------ 4

    4. HHT Operation -------------------------------------------- 5 4.1 HHT Display & Key 4.2 HHT Menu diagram

    5. Calibration ------------------------------------------------ 6 5.1 Data 5.1.1 Monitor/01_BASIC MENU 5.1.2 Monitor/03_ERROR MENU 5.1.3 Program/01_CONTROL MENU 5.1.4 Interface Menu 5.1.5 Factory Menu

  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 3 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    1. Specification

    Part HIDC.INT7I.UM HIDC.INT7I.UH

    Input supply Single Phase AC 220 V 15% / 60 Hz 5% (Input Voltage lines must not connect to frame ground )

    Applicable motor 3 AC220V, 400 W, 4P, 1.9 A 3 AC220V, 750 W, 4P, 3.8 A

    Applicable encoder 2500 ppr, Line Drive, 5Vdc

    Control type Sensored Vector Control

    Switching Frequency 10 KHz

    Ambient Temperature .10 to +40 Storage Temperature .20 to +60

    Ambient Humidity 20 ~ 90% RH (Non.condensation)

    Input Signals Open/Close signals(OP, CL, NUD), Limit signals(OPL, CLL), Control signal( RST ), Encoder signals(A,/A,B,/B)

    Output Signals OPL, CLL, CLS, 30B, LDT

    Protective Function Under Voltage, Over Voltage, Over Current, Over Load, Encoder Error, IPM Fault, Inverter Over Temperature, Over Speed

    2. System Diagram

    Figure 1 Door inverter main board

  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 4 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    3. External Connectors

    Connector Symbol Name Description CN12 OPL OPL Signal Open Limit switch, input

    CN13 CLL CLL Signal Close Limit switch, input

    CN15 CLS CLUTCH Operating Signal CLUTCH Operating Signal, input

    CN10

    OPB OPL B Contact Open Limit switch signal B contact, output

    OPC OPL C Contact Open Limit switch signal C contact, output

    CLB CLL B Contact Close Limit switch signal B contact, output

    CLC CLL C Contact Close Limit switch signal C contact, output 30B 30 B Signal Door Controller error signal, output

    LDT Load Detect Signal Door Controller Load Detect signal, output OP Open Command Door Open Command, input

    CL Close Command Door Close Command, input

    NUD Nudge Command Door Nudge Close Command, input Controller Reset Command, input RST Reset Command Controller Reset Command, input

    CN9 24V +24 V Power supply +24 V power supply, input

    CM Common ( 0 V ) +24 V Common ( 0 V ), input

    CN8

    VEN Encoder Power Supply (5V) Encoder power supply ( 5 V ), output

    OVE Encoder Common ( 0V ) Encoder Common ( 0 V ), output

    A Phase A Phase A, input

    /A Inv Phase A Inv Phase A, input

    B Phase B Phase B, input

    /B Inv Phase B Inv Phase B, input

    CN1

    R AC 220 V input Input power supply terminal of door controller

    S AC 220 V input Input power supply terminal of door controller

    U Inverter output, U phase Output terminal, U.phase of door controller

    V Inverter output, V phase Output terminal, V.phase of door controller

    W Inverter output, W phase Output terminal, W.phase of door controller FG FG Inverter ground Frame ground of door controller

  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 5 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    4. HHT Operation 4.1 HHT Display & Key

    4.2 HHT Menu daigram

    The keypad menu of HIDC uses a tree data structure as shown in Figure.

    Door controller logo is displayed in the topmost node. It has 2 sub.menu, [MONITOR] and

    [PROGRAM] [MONITOR] is composed of [BASIC], [I/O] and [ERROR] [PROGRAM] is

    composed of [CONTROL], [INTERFACE], [FACTORY] Each menu has its own information

    according to the properties.

  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 6 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    5. Calibration The total moving length should be accurately measured in order to drive the door with

    programmed Open/Close pattern. In case of first installment, replacement of a door

    inverter or changing a parameter of [33_System_Ratio] or [36_Motor_Select] in

    [01_CONTROL] menu, CALIBRATION is required.

    In case that a door operator is not standard or phase.order of motor is not

    incorrect, See details below.

    1. Make sure of connectors between door inverter and motor check the direction of

    rotation of the motor while the door is being opened. If the direction of rotation is counter

    clockwise, phase.order of motor and inverter is correct. If it is clockwise, change U.V.W

    phase.order to U.W.V phase.order.

    2 . Make sure of the value of measured speed in [01_MONITOR/01_BASIC/02_FBK

    RPM] connect the jumper of CON2 in inverter control board to 1.2 or 2.3 in order that

    the value of [02_FBK RPM Rpm] is positive while the door is being opened.

    Check before Calibration

    1. Make sure connections of Open limit switch and Close limit switch are correct OPL

    LED is ON when the door is opened fully and CLL LED is ON when the door is closed

    fully in a state of correct connections.

    2. The parameter can not be changed with a fully opened door. Do the calibration with a

    fully closed door or in the middle of opening/closing (OLS OFF and CLS OFF).

  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 7 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    Process of Calibration

    1. Adjust [PROGRAM/01_CONTROL/38_Keypad_Run] to ON.

    2. Make sure of [PROGRAM/01_CONTROL/36_Motor_Select]

    ( INT7I.UM = 400IM, INT7I.UH = 750IM )

    3. Adjust [PROGRAM/01_CONTROL/35_Door_Type] to installed door type.

    ( Center Open = CO, Side Open = SO )

    4. Adjust [PROGRAM/01_CONTROL/34_JJ] to JJ of installed door.

    5. Change the parameter in [PROGRAM/01_CONTROL/32_Calibration] to "1"

    calibration will then be operated.

    6. After Calibration is finished, [PROGRAM/01_CONTROL/32_Calibration] is changed

    to "2", [38_Keypad_Run] is changed to "0", [31_Total_Length] is changed to measured

    total length of door and Door Inverter is in Auto Mode automatically. It is then driven by

    C.P command.

  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 8 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    5.1 Data 5.1.1 Monitor/01_BASIC MENU

    ITEM FUNCTION NAME UNIT NOTE

    01 BASIC

    01_REF_RPM rpm Command value of motor speed

    02_FBK_RPM rpm Measured value of motor speed

    03_REF_MMPS mmps Command value of door speed

    04_FBK_MMPS mmps Measured value of door speed

    05_DC_Volt Vdc DC Link Voltage

    06_Running_mm mm Moving length of the door

    07_Rth . Temperature of IPM

    08_Iu_Offset A Offset of U.phase current

    09_Iw_Offset A Offset of W.phase current

    10_RMS_Current Arms RMS output current of door controller

    11_D.REF_MMPS mmps Commanded max speed while the door is being driven by pattern.

    12_D.FBK_MMPS mmps Measured max speed while the door is being driven by pattern. 5.1.2 Monitor/03_ERROR MENU

    ERROR KEYPAD DISPLAY DESCRIPTION

    NO ERROR NONE No generated error.

    IPM ERROR(H/W) HW IPM IPM error signal is detected (Occurred immediately)

    IPM ERROR(S/W) SW IPM IPM error signal is detected during setting time. (Setting time : 300usec)

    OVER CURRENT SW OC Output current is higher than a level (level : 400 %, Occurred immediately) UNDER VOLTAGE

    ERROR SW UV DC Link voltage is lower than a level during setting time. (level : 65%, setting time : 500 usec)

    OVER VOLTAGE ERROR SW OV

    DC Link voltage is higher than a level during setting time. (level : 130%, setting time : 500 usec)

    SPI COMMUNICATION

    ERROR SPI FAULT SPROM communication error (when it occurred 2 times consecutively)

    VERSION ERROR Version Error SPROM Version is different from Main Board Version. (Occurred immediately)

  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 9 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    5.1.2 Monitor/03_ERROR MENU (Continue)

    ERROR KEYPAD DISPLAY DESCRIPTION

    INVERTER OVERHEAT Over Heat

    IPM temperature is higher than allowable temperature during setting time (setting time : 60 sec)

    OVER LOAD ALERT1

    Over Load LV1

    Load current is higher than "level1" during "time1" (level1 : 200%, time1 : 5sec)

    OVER LOAD ALERT2

    Over Load LV2

    Load current is higher than "level2" during "time2" (level2 : 150%, time2 : 30sec)

    OVERLOAD ALERT3

    Over Load LV3

    Load current is higher than "level3" during "time3" (level3 : 110%, time3 : 60sec)

    OVERSPEED ALERT Over Speed

    The motor speed is higher than a level during setting time (level : 110%, setting time : 10msec)

    UNKNOWN ERROR Unknown Error Unknown error is generated.

    5.1.3 Program/01_CONTROL MENU

    ITEM FUNCTION NAME MAX MIN INT7I.UH INT7I .UM UNIT REMARK

    01 CONTROL

    01_OP_Start_sec 0.100 2.000 1.000 0.750 sec 02_OP_Start_Spd 20 500 50 44 mmps 03_OP_Acc 100 1000 400 500 mmps^2 04_OP_Max_Speed 100 1200 400 400 mmps 05_OP_Dec 100 1000 400 500 mmps^2 06_OP_Creep_mm 1 100 5 15 mm 07_OP_Creep_Spd 1 500 10 50 mmps 08_OPL_On_Dec 100 1000 200 300 mmps^2 09_OP_Torque 10 300 150 150 % 10_OP_Lock_Force 10 200 20 80 % 11_CL_Acc 100 1000 325 400 mmps^2 12_CL_Max_Spd 100 1000 300 300 mmps 13_CL_Dec 100 1000 325 400 mmps^2 14_CL_Creep_mm 1 100 5 30 mm 15_CL_Creep_Spd 1 100 10 27 mmps 16_CLS_On_sec 0.100 2.000 0.500 0.300 sec 17_CLS_On_Spd 1 500 90 15 mmps 18_CL_Torque 10 300 120 120 %

  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 10 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    5.1.3 Program/01_CONTROL MENU(Continue)

    ITEM FUNCTION NAME MAX MIN INT7I.UH INT7I .UM UNIT REMARK

    01 CONTROL

    19_CL_Lock_Force 10 200 20 80 %

    20_Nudge_Speed 100 600 150 150 mmps

    21_Stop_Dec 100 1000 450 900 mmps^2

    22_ReAct_Acc 100 1000 450 900 mmps^2

    23_Jog_Speed 50 200 100 100 mmps

    24_Jog_Acc 100 1000 200 300 mmps^2

    25_CLL_On_Spd 1 500 90 15 mmps Only UH Type 26_CL_LOW_Max_Spd 1 1200 200 200 mmps

    27_USE_CAN OFF ON ON ON .

    28_Reserved . . 0 0 . No modification29_Belt_Slip_MM 100 3000 100 100 mm

    30_CLS2CLL_MM . . * * mm

    31_Total_Length . . * * mm

    32_Calibration 0 1 0 0 .

    33_System_Ratio 10 150 25 70 mm/rev

    34_JJ 100 3000 900 1000 mm

    35_Door_Type CO SO CO CO .

    36_Motor_Select 200 IM 750 IM 750 IM 400 IM .

    37_Keypad_Cmd STOP NUDGE STOP STOP .

    38_Keypad_Run OFF ON OFF OFF .

    39_CL 0 Run Use OFF ON ON ON .

    Note) UH Type and UM Type have different door mechanism and control programs and therefore are

    not compatible use the correct type to your door system.

  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 11 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    Figure 1 While the door is being opened, the pattern of speed & signals

    Figure 2 While the door is being closed, the pattern of speed & signals

    (HIDC.INT7I.UH type)

  • THE EL Door Controller Operating Manual Rev. 0.0 Date 2010.11.11

    Page 12 / 12

    R&D institute VOLUME 1. A4 (210X297 mm)

    5.1.4 Interface Menu

    ITEM FUNCTION NAME MINIMUMVALUE MAXIMUM

    VALUE INITIAL VALUE UNIT NOTE

    02_ INTERFACE

    01_DAC_Ch1_SLT

    HIDC has analog outputs in order to measure the actual driving conditions with a measuring instrument.These menus set the measurement targets and ranges.

    02_DAC_Ch1_Max

    03_DAC_Ch2_SLT

    04_DAC_Ch2_Max

    05_DAC_Ch3_SLT

    06_DAC_Ch3_Max

    07_DAC_Ch4_SLT

    08_DAC_Ch4_Max

    09_Reserved . . . . No modified10_Error Clear OFF ON OFF .

    11_SPROM_Init OFF ON OFF .

    12_Flash_Ver . . . . No modified

    13_SPROM_Ver . . . . No modified14 CTRL Init OFF ON OFF .

    5.1.5 Factory Menu Parameters in FACTORY MENU are set when HIDC.INT7I is produced at factory. These are protected to not change with secret number.